首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
A simple, sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3,000 mass spectrometer was equipped with a TurboIonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100 ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput of urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers.  相似文献   

2.
Nitric oxide (NO) is synthesized by NO synthase from L-arginine, which can be competitively blocked by endogenous inhibitors such as asymmetric dimethylarginine (ADMA), but not by symmetric dimethylarginine (SDMA). ADMA is degraded by dimethylarginine dimethylaminohydrolase (DDAH) to dimethylamine and citrulline. A growing number of published clinical studies documented a strong correlation between increased ADMA blood levels and cardiovascular morbidity and mortality. We present here a highly sensitive method for the determination of this compounds in plasma and urine by means of HPLC-MS. The sample preparation is very simple and comprises only protein precipitation and concentration in the case of plasma samples and dilution in the case of urine. The samples are derivatized automatically with orthophthaldialdehyde and 2-mercaptoethanol, are separated on a 250 mm x 4 mm RP18 column by gradient elution with formate buffer/methanol and are detected by ESI-MS. The calibration functions are linear and cover the range from normal to pathologic concentration values of the analytes. The intra-day relative standard deviation (R.S.D.) of the assay for ADMA in plasma is 7.5% and the corresponding inter-day R.S.D. is 5.7%. In urine, these values for ADMA are 3.8 and 6.4%, respectively. All other analytes in plasma as well as in urine exhibit intra-day R.S.D. below 8%. The corresponding inter-day R.S.D. are all below 13%.  相似文献   

3.
We have developed a method to measure 12 urinary phenolic metabolites of pesticides or related chemicals. The target chemicals for our method are 2-isopropoxyphenol; 2,4-dichlorophenol; 2,5-dichlorophenol; carbofuranphenol; 2,4,5-trichlorophenol; 2,4,6-trichlorophenol; 3,5,6-trichloro-2-pyridinol; para-nitrophenol, ortho-phenylphenol, pentachlorophenol, 1-naphthol and 2-naphthol. The sample preparation involves enzyme hydrolysis, isolation of the target chemicals using solid phase extraction cartridges, a phase-transfer catalyzed derivatization, cleanup using sorbent-immobilized liquid/liquid extraction cartridges, and concentration of the sample. Derivatized samples are analyzed by capillary gas chromatography-tandem mass spectroscopy using isotope dilution calibration for quantification. The limits of detection are in the mid ng/L range and the average coefficient of variation was below 15% for most of the analytes. Using our method, we measured concentrations of the target chemicals in urine samples from the general population.  相似文献   

4.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of nicotine (NIC), cotinine (COT), nornicotine (NNIC), norcotinine (NCOT), nicotine-N-β-D-glucuronide (NIC GLUC), cotinine-N-β-D-glucuronide (COT GLUC), nicotine-1'-oxide (NNO), cotinine-N-oxide (CNO), trans-3'-hydroxycotinine (3-HC), anabasine (AB) and anatabine (AT) was modified and validated for quantification of these selected analytes in rat brain tissue. This analytical method provides support for preclinical NIC pharmacokinetic and toxicological studies after controlled dosing protocols. After brain homogenization and solid-phase extraction, target analytes and corresponding deuterated internal standards were chromatographically separated on a Discovery(?) HS F5 HPLC column with gradient elution and analyzed by LC-MS/MS in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. Method linearity was assessed and calibration curves were determined over the following ranges: 0.1-7.5 ng/mg for NIC, COT GLUC and AB; and 0.025-7.5 ng/mg for COT, NNIC, NCOT, NIC GLUC, NNO, CNO, 3-HC and AT (R(2)≥0.99 for all analytes). Extraction recoveries ranged from 64% to 115%, LC-MS/MS matrix effects were ≤21%, and overall process efficiency ranged from 57% to 93% at low and high quality control concentrations. Intra- and inter-assay imprecisions and accuracy for all analytes were ≤12.9% and ≥86%, respectively. The method was successfully applied to quantification of NIC and metabolites in the brain of post-natal day 90 rats that were sacrificed 2-h after a single 0.8 mg/kg s.c. administration of (-)NIC. In these tissues, striatal concentrations were 204.8±49.4, 138.2±14.2 and 36.1±6.1 pg/mg of NIC, COT and NNIC, respectively. Concentrations of NIC, COT and NNIC in the remaining whole brain (RWhB) were 183.3±68.0, 130.0±14.1 and 46.7±10.3 pg/mg, respectively. Quantification of these same analytes in plasma was also performed by a previously validated method. NIC, COT, NNIC, NCOT, NNO and CNO were detected in plasma with concentrations comparable to those reported in previous studies. However, and in contrast to brain tissues, COT concentrations in plasma were significantly higher than were those of NIC (194.6±18.6 ng/mL versus 52.7±12.9 ng/mL). Taken together, these results demonstrate that a sensitive and selective method has been developed for the determination of NIC biomarkers in rat brain.  相似文献   

5.
Uric acid is a potent antioxidant and scavenger of singlet oxygen and other radicals in humans. Allantoin, the predominant product of free radical-induced oxidation of uric acid, is efficiently excreted in the urine and has potential as a biomarker of oxidative stress. We developed a rapid and specific assay for urinary allantoin using ultra-performance liquid chromatography-tandem mass spectrometry suitable for high-throughput clinical studies. The method required minimal sample preparation and was accurate (mean error = 6%), precise (intra- and interday imprecision <8%), and sensitive (limit of detection = 0.06 pmol). Allantoin levels measured in control samples were comparable to literature values.  相似文献   

6.
A stereoselective bioanalytical method for the simultaneous quantification of the enantiomers of verapamil and its active main metabolite norverapamil in human plasma has been developed and validated. The samples were analysed by liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) in the Selected Reaction Monitoring (SRM) mode using a deuterated internal standard. The stationary phase used for the chiral separation was a Chiral-AGP. The enantiomers of verapamil were selectively detected from those of norverapamil by the mass spectrometer due to different molecular masses, although there was a chromatographic co-elution. Thus, time-consuming procedures like achiral preseparation or chemical derivatisation could be avoided. Higher detection sensitivity than earlier published methods based on fluorescence detection was obtained, although a mobile phase of high water-content and high flow-rate was introduced into the electrospray interface (85% aqueous ammonium acetate pH 7.4 +15% acetonitrile at 0.6 ml/min). The enantiomers of verapamil and norverapamil could be quantified at levels down to 50 pg and 60 pg/500 microl plasma sample, respectively, with R.S.D. in the range of 3.6-7.8%. The presented method was successfully applied to an in vivo intestinal absorption and bioavailability study in humans, using the Loc-I-Gut method.  相似文献   

7.
A liquid chromatography-mass spectrometry method (LC-MS/MS) for the quantitative determination of rifaximin in human plasma was developed and validated. In the developed procedure, metoprolol was added to human plasma as an internal standard (IS) and acetonitrile was used to precipitate the plasma proteins before LC-MS/MS analysis. Chromatographic separation was obtained on a RESTEK Pinnacle C18 column (50 mm x 2.1mm, 5 microm) with a mobile phase consisted of ammonium acetate solution (15 mM, pH 4.32) as buffer A and methanol as mobile phase B. Quantification was performed in positive mode using multiple reaction monitoring (MRM) of the transitions m/z 786.1-->754.1 for rifaximin and m/z 268.3-->116.1 for the IS. The assay has been validated over the concentration range of 0.5-10 ng/ml (r=0.9992) based on the analysis of 0.2 ml of plasma. The assay accuracy was between 98.2% and 109%. The within-day and between-day precision was better than 3.9% and 8.9% at three concentration levels. The freeze-thaw stability was also investigated and it was found that both rifaximin and the IS were quite stable. This method provides a rapid, sensitive, specific and robust tool for the quantitative determination of rifaximin in human plasma, which is especially useful for the pharmacokinetic study of rifaximin.  相似文献   

8.
A method is described for the determination of the neutral metabolites formed from catecholamines and various other structurally related phenylethylamines by using gas chromatography—chemical ionization—mass spectrometry. These metabolites (phenylglycols and phenylethanols) were extracted from urine specimens and converted to pentafluoropropionyl derivatives which were separated on either 3% OV-1, 3% SP-2250, or 3% QF-1 packed columns. Our results demonstrate the presence in human urine of p-hydroxyphenylglycol, a metabolite of octopamine. One patient excreted 13 and 91 μg/day of free and total (free + conjugated) p-hydroxyphenylglycol, respectively. Treatment with a monoamine oxidase inhibitor reduced the excretion of total p-hydroxyphenylglycol to 30% of baseline level.  相似文献   

9.
A new developed gas chromatographic-high resolution mass spectrometric method for the sensitive simultaneous determination of trans-chrysanthemumdicarboxylic acid, cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane carboxylic acid, cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane carboxylic acid, 3-phenoxybenzoic acid and 4-fluoro-3-phenoxybenzoic acid in human urine is presented. These metabolites are biomarkers for an exposure to pyrethrum, allethrin, resmethrin, phenothrin, tetramethrin, cyfluthrin, cypermethrin, deltamethrin or permethrin. Therefore, with the help of this method for the first time a complete assessment of exposure to pyrethroid and pyrethrin insecticides is possible. After acid hydrolysis and extraction with tert-butyl-methyl-ether the residue is derivatized with 1,1,1,3,3,3-hexafluoroisopropanol and analyzed by GC/HRMS in electron impact mode (detection limits < 0.1 microg/l) as well as in negative chemical ionization mode (detection limit < 0.05 microg/l urine).  相似文献   

10.
A sensitive and selective analytical method based on liquid chromatography-triple-quadrupole mass spectrometer has been developed to determine mildronate in human plasma and urine. The aim of this work was to find a valid method to study the pharmacokinetic profiles of mildronate in humans. Mildronate is a heart protection medicine, a carnitine's structural analogue, so levocarnitine was used as an internal standard for quantification. Under the electrospray ionization source positive ion mode, calibration curves with good linearities (r=0.9998 for plasma sample and r=0.9999 for urine sample) were obtained in the range of 1.0-20,000 ng ml(-1) for mildronate. The detection limit was 1 ng ml(-1). Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of mildronate in humans, and to the best of our knowledge, this is the first report on LC-MS-MS analysis of mildronate in plasma and urine.  相似文献   

11.
A sensitive, specific and reproducible method for the quantitative determination of kavain in human hair has been developed. The sample preparation involved a decontamination step of the hair with methylene chloride. The hair sample (about 50 mg) was incubated in 1 ml of methanol for 1 h, in an ultrasonic bath, in presence of 20 ng of methaqualone-d7 used as internal standard. The methanolic solution was evaporated to dryness, and the residue reconstituted by adding 30 microl of methanol. A 2 microl aliquot of the extract was injected onto the column (Optima5-MS capillary column, 5% phenyl-95% methylsiloxane, 30 m x 0.25 mm i.d. x 0.25 mm film thickness) of a Hewlett-Packard (Palo Alto, CA) gas chromatograph (5890). Kavain was detected by its parent ion at m/z 230 and daughter ions at m/z 111 and 202 through a Finnigan TSQ 700 MS/MS system. The assay was capable of detecting 30 pg/mg of kavain (limit of detection (LOD)). Linearity was observed for kavain concentrations ranging from 100 to 2000 pg/mg with a correlation coefficient of 0.998. Intra-day precision at 400 pg/mg was 13.7%. The analysis of a segment of hair, obtained from an occasional consumer, revealed the presence of kavain at the concentration of 418 pg/mg. A higher concentration (1708 pg/mg) was detected in the corresponding pubic hair.  相似文献   

12.
We developed a selective method to measure riboflavin in human urine. Sample preparation involved solid phase extraction and concentration of the target analyte in urine. The urine concentrate was analyzed using high performance liquid chromatography-tandem mass spectrometry. Riboflavin concentrations were quantified using an isotopically labeled internal standard. The limit of detection was 11 ng/mL, and the linear range was 4.4-20,000 ng/mL. The relative standard deviation at 100, 1000, and 5000 ng/mL was 17%, 17%, and 12%, respectively. The accuracy was 90%. On average, 100 samples, including calibration standards and quality control samples, were prepared per day. Using our method, we measured concentrations of riboflavin in human urine samples that were collected from participants in a study where riboflavin was used as a surrogate chemical to simulate exposure to an environmental toxicant.  相似文献   

13.
A rapid, sensitive, and highly selective liquid chromatography-tandem mass spectrometry method was developed and validated for simultaneous determination of enalapril and its major active metabolite enalaprilat in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax Extend-C(18) column, and detected by tandem mass spectrometry with a Turbo IonSpray ionization interface. The method has a lower limit of quantification (LLOQ) of 0.1 ng/ml for both enalapril and enalaprilat. The chromatographic run time was approximately 3.5 min. The standard calibration curves for both enalapril and enalaprilat were linear in the concentration ranges of 0.10-100.0 ng/ml in human plasma. The intra- and inter-run precisions, expressed as the relative standard deviation (R.S.D.), were less than 7.7 and 7.8%, determined from QC samples for enalapril and enalaprilat, and accuracy was within +/-3.9 and +/-2.7% in terms of relative error, respectively. The method was successfully applied for the evaluation of the pharmacokinetics of enalapril and enalaprilat in 20 volunteers after an oral dose of 10 mg enalapril maleate.  相似文献   

14.
A method based on liquid chromatography tandem mass spectrometry (LC-MSMS) applying atmospheric pressure chemical ionisation (APCI) in the positive ion mode was developed for the direct determination of nicotine, cotinine, trans-3'-hydroxycotinine, their corresponding glucuronide conjugates as well as cotinine-N-oxide, norcotinine, and nicotine-N'-oxide in the urine of smokers. The assay involves filtration of crude urine, fast liquid chromatography on a reversed-phase column and mass-specific detection using MSMS transitions. Deuterium-labeled nicotine, cotinine, and trans-3'-hydroxycotinine were used as internal standards. Glucuronides used as reference material were either chemically (cotinine-N-glucuronide) or enzymatically synthesized (nicotine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide). Precision for the major nicotine analytes at levels observable in urine of smokers was better than 10%. Accuracy expressed in recovery rates in urine matrix for nicotine, cotinine, trans-3'-hydroxycotinine, and cotinine-N-glucuronide ranged from 87 to 113%. Quantitative results for the three glucuronides in urine samples of 15 smokers were compared to an indirect method in which the aglycons were determined with gas chromatography and nitrogen-selective detection (GC-NPD) before and after enzymatic splitting of the conjugates. Good agreement was found for cotinine-N-glucuronide (coefficient of variation, CV: 9%) and trans-3'-hydroxycotinine-O-glucuronide (CV: 20%), whereas the accordance between both methods was moderate for nicotine-N-glucuronide (CV: 33%). The described LC-MSMS method allows the simultaneous determination of nicotine and eight of its major metabolites in urine of smokers with good precision and accuracy. Since the method requires a minimum of sample clean-up and a very short time for chromatography (3 min), it is suitable for determining the nicotine dose in large-scale human biomonitoring studies.  相似文献   

15.
Gemcitabine-squalene is a new prodrug that self-organizes in water forming nanoassemblies. It exhibits better anti-cancer properties in vitro and in vivo than gemcitabine. A liquid chromatography/tandem mass spectrometry assay of gemcitabine-squalene and gemcitabine was developed in human plasma in order to quantitate gemcitabine and its squalene conjugate. After protein precipitation with acetonitrile/methanol (90/10, v/v), the compounds were analyzed by reversed-phase high performance liquid chromatography and detected by tandem mass spectrometry using multiple reaction monitoring. The method was linear over the concentration range of 10-10,000 ng/ml of human plasma for both compounds with an accuracy lower than 10.4% and a precision below 14.8%. The method showed a lower limit of quantitation of 10 ng/ml of human plasma for dFdC and dFdC-SQ. A preliminary in vivo study in mice was shown as application of the method as no significant difference between human and mice plasma for the analysis of dFdC and dFdC-SQ was demonstrated.  相似文献   

16.
A selective and sensitive method has been developed and validated for simultaneous quantification of methylephedrine and noscapine in human plasma. Analytes were extracted from human plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column and detected by tandem mass spectrometer with an atmospheric pressure chemical ionization (APCI) interface. Diphenhydramine was used as the internal standard (I.S.). The method was found to be precise and accurate within the linear range 0.1-100 ng/ml for each analyte. The intra- and inter-day relative standard deviations (R.S.D.s) were below 5.2% for methylephedrine and 6.7% for noscapine. The inter-day relative error (RE) as determined from quality control samples (QCs) was less than 3.0% for each analyte. The assay was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation containing 20 mg DL-methylephedrine hydrochloride, 16 mg noscapine, 300 mg paracetamol and 1mg of chlorpheniramine maleate.  相似文献   

17.
A selective and sensitive method for the simultaneous determination of hypericin and hyperforin--the two main active ingredients of St. John's Wort (SJW) extract--in human plasma depending on liquid/liquid-extraction and LC/MS/MS detection has been developed, validated after specifying the stability of the photosensitive hypericin in plasma samples during light exposure and applied to samples of a patient. After extraction with ethyl acetate/n-hexane in the darkness, sample extracts were chromatographed isocratically within 6 min on a Kromasil RP-18 column. The analytes were detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source. The limit of quantification was 0.05 ng/mL for hypericin and 0.035 ng/mL for hyperforin. The accuracy of the method varied between 101.9 and 114.2% and the precision ranged from 4.7 to 15.4% (S.D., batch-to-batch) for both analytes. The method was linear at least between 0.05 and 10 ng/mL for hypericin and between 0.035 and 100 ng/mL for hyperforin. Using this method hypericin and hyperforin were determined successfully in a patient over seven days following discontinuation of exposure with therapeutic doses of St. John's Wort extract.  相似文献   

18.
A high-throughput analytical method was developed for the measurement of asymmetric dimethylarginine (ADMA) and L-arginine (ARG) from plasma using LC/MS/MS. The sample preparation was simple and only required microfiltration prior to analysis. ADMA and ARG were assayed using mixed-mode ion-exchange chromatography which allowed for the retention of the un-derivatized compounds. The need for chromatographic separation of ADMA from symmetric dimethylarginine (SDMA) was avoided by using an ADMA specific product ion. As a result, the analytical method only required a total run time of 2 min. The method was validated by linearity, with r2>or=0.995 for both compounds, and accuracy, with no more than 7% deviation from the theoretical value. The estimated limit of detection and limit of quantification were suitable for clinical evaluations. The mean values of plasma ADMA and ARG taken from healthy volunteers (n=15) were 0.66+/-0.12 and 87+/-35 microM, respectively; the mean molar ratio of ARG to ADMA was 142+/-81.  相似文献   

19.
Asymmetric dimethylarginine (ADMA; N(G),N(G)-dimethyl-L-arginine) is the most important endogenous inhibitor of nitric oxide synthase and a potential risk factor for cardiovascular diseases. This article describes a gas chromatographic-tandem mass spectrometric (GC-tandem MS) method for the accurate quantification of ADMA in human plasma or serum and urine using de novo synthesized [2H(3)]-methyl ester ADMA (d(3)Me-ADMA) as the internal standard. Aliquots (100 microl) of plasma/serum ultrafiltrate or native urine and of aqueous solutions of synthetic ADMA (1 microM for plasma and serum; 20 microM for urine) are evaporated to dryness. The residue from plasma/serum ultrafiltrate or urine is treated with a 100 microl aliquot of 2M HCl in methanol, whereas the residue of the ADMA solution is treated with a 100 microl aliquot of 2M HCl in tetradeuterated methanol. Methyl esters are prepared by heating for 60 min at 80 degrees C. After cooling to room temperature, the plasma or urine sample is combined with the d(3)Me-ADMA sample, the mixture is evaporated to dryness, the residue treated with a solution of pentafluoropropionic (PFP) anhydride in ethyl acetate (1:4, v/v) and the sample is incubated for 30 min at 65 degrees C. Solvent and reagents are evaporated under a stream of nitrogen gas, the residue is treated with a 200 microl aliquot of 0.4M borate buffer, pH 8.5, and toluene (0.2 ml for plasma, 1 ml for urine). Reaction products are extracted by vortexing for 1 min, the toluene phase is decanted, and a 1 microl aliquot is injected into the GC-tandem MS instrument. Quantitation is performed by selected reaction monitoring (SRM) of the common product ion at m/z 378 which is produced by collision-induced dissociation of the ions at m/z 634 for endogenous ADMA and m/z 637 for d(3)Me-ADMA. In plasma and urine of healthy humans ADMA was measured at concentrations of 0.39+/-0.06 microM (n=12) and 3.4+/-1.1 micromol/mmol creatinine (n=9), respectively. The limits of detection and quantitation of the method are approximately 10 amol and 320 pM of d(3)Me-ADMA, respectively.  相似文献   

20.
A simple detection system with a high-performance liquid chromatography (HPLC) with positive ionisation-tandem mass spectrometry (ESI-MS/MS) for determining diphemanil methylsulphate (DMS) levels in human plasma using 4-diphemanylmethylene,1-methylpiperidine as an internal standard (I.S.), is proposed. The acquisition was performed with the multiple reactional monitoring (MRM) mode, by monitoring the transitions: m/z 278>262 for DMS and m/z 263>247 for the I.S. The method involved a simple single-step deproteinisation with acetonitrile. The analyte was chromatographed on a Zorbax C18 reversed-phase chromatographic column by isocratic elution with 10(-3)M ammonium acetate and 10(-3)M hexafluorobutyric acid, adjusted to pH 7.0 with ammoniac/acetonitrile (40/60, v/v). The results were linear over the studied range (0.5-50.0 ng mL(-1)) and the total analysis time for each run was 10 min. The mean extraction apparent recoveries expressed at the 95% intervals of confidence were 94-104% for DMS and 92-106% for the I.S. The intra- and inter-assay precisions were 4.6-8.4% and 2.9-10.6%, respectively. The limit of quantification was 0.15 ng mL(-1). The devised assay was successfully applied to the residual concentrations monitoring in infant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号