共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel and sensitive immunosensor has been developed by electro-depositing gold nanoparticles on to a Prussian Blue-modified
glassy carbon electrode for determination of hepatitis B surface antigen (HBsAg). After the developed immunosensor was incubated
with different concentrations of HBsAg samples at 37°C for 15 min, the current response decreased with an increasing HBsAg
concentration in the sample solution. The decreased percentage of the current was proportional to HBsAg concentration ranging
from 2 to 300 ng HbsAg ml−1 with a detection limit of 0.42 ng HbsAg ml−1 (S/N = 3). Analytical results of 50 specimens using the developed immunosensor showed satisfactory agreement with those using
ELISA, indicating the method to be a promising alternative for detecting HBsAg in clinical diagnosis. 相似文献
2.
Optimizing antibody immobilization strategies for the construction of protein microarrays 总被引:11,自引:0,他引:11
Peluso P Wilson DS Do D Tran H Venkatasubbaiah M Quincy D Heidecker B Poindexter K Tolani N Phelan M Witte K Jung LS Wagner P Nock S 《Analytical biochemistry》2003,312(2):113-124
Antibody microarrays have the potential to revolutionize protein expression profiling. The intensity of specific signal produced on a feature of such an array is related to the amount of analyte that is captured from the biological mixture by the immobilized antibody (the "capture agent"). This in turn is a function of the surface density and fractional activity of the capture agents. Here we investigate how these two factors are affected by the orientation of the capture agents on the surface. We compare randomly versus specifically oriented capture agents based on both full-sized antibodies and Fab' fragments. Each comparison was performed using three different antibodies and two types of streptavidin-coated monolayer surfaces. The specific orientation of capture agents consistently increases the analyte-binding capacity of the surfaces, with up to 10-fold improvements over surfaces with randomly oriented capture agents. Surface plasmon resonance revealed a dense monolayer of Fab' fragments that are on average 90% active when specifically oriented. Randomly attached Fab's could not be packed at such a high density and generally also had a lower specific activity. These results emphasize the importance of attaching proteins to surfaces such that their binding sites are oriented toward the solution phase. 相似文献
3.
Danczyk R Krieder B North A Webster T HogenEsch H Rundell A 《Biotechnology and bioengineering》2003,84(2):215-223
This study investigates the influence of antibody immobilization methods on antigen capture. Adsorption and two surface chemistries, an aminosilane chemistry and a common heterobifunctional crosslinker (N-gamma-maleimidobutyryloxy-succinimide ester, GMBS), were compared and evaluated for their ability to immobilize antibodies and capture antigen. The role of protein A as an orienting protein scaffold component in each of these techniques was also evaluated. Through experimentation it was determined that the GMBS technique immobilized the highest amount of antibody and minimized nonspecific binding. For all techniques, the most functional antibodies were found to be those immobilized with protein A. Interestingly, the aminosilane technique demonstrated the highest antigen capture with antibody alone but also exhibited the highest level of nonspecific binding. 相似文献
4.
Bo Feng Caiyun Wang Xiaomei Xie Xi Feng Yuqin Li Zhijian Cao 《Biochemical and biophysical research communications》2014
Polystyrene is a common substrate material for protein adsorption in biosensors and bioassays. Here, we present a new method for multilayered, site-directed immobilization of antibody on polystyrene surface through the linkage of a genetically engineered ligand and the assembly of staphylococcal protein A (SPA) with immunoglobulin G (IgG). In this method, antibodies were stacked on polystyrene surface layer by layer in a potential three-dimensional way and exposed the analyte-binding sites well. Enzyme-linked immunosorbent assay (ELISA) revealed that the new method showed a 32-fold higher detection sensitivity compared with the conventional one. Pull-down assay and Western blot analysis further confirmed that it is different from the ones of monolayer adsorption according to the comparison of adsorption capacity. The differentiated introduction of functional ligands, which is the key of this method, might offer a unique idea as a way to interfere with the dynamic behavior of a protein complex during the process of adsorption. 相似文献
5.
Real-time investigation of molecular recognition between protein and the photosensitizer of photodynamic therapy (PDT) was carried out by a quartz crystal microbalance (QCM) sensor integrated into a flow injection analysis (FIA) system. The photosensitizer meso-tetrakis(4-hydroxyphenyl)porphyrin (p-THPP) was immobilized on the gold electrode of the QCM chip by combining the sol-gel and self-assembly methods. Such a rapid screen analysis of molecular recognition showed that the p-THPP-immobilized sensor exhibited sensitive and specific interaction only with hemoglobin (Hb). The kinetic rate constants (kass and kdiss) and the equilibrium association constant (KA) for p-THPP-Hb interaction were calculated by linear regression. The sensing performance characteristics of the proposed sensor were investigated. The sensor showed excellent selectivity, reproducibility, and repeatability for the detection of Hb. A linear calibration plot was obtained over a range from 0.2 to 1.0 μM with a detection limit (signal/noise ratio = 3) of 0.15 μM. The response mechanism of the sensor is discussed in detail. Due to its low cost and simple manipulation, this QCM-FIA system was shown to be a highly effective method for the investigation of interaction between biomacromolecules and the PDT photosensitizer. It also provides a potential strategy for screening an efficient and less harmful photosensitizer for PDT application. 相似文献
6.
A label-free electrochemical immunosensor based on Nafion/carbon nanotubes (CNTs)/charged pyridinecarboxaldehyde composite film was developed for the detection of hepatitis B surface antigen. Nafion/CNTs/charged pyridinecarboxaldehyde nanocomposites were prepared by dispersing charged pyridinecarboxaldehyde and CNTs in Nafion solution. The nanocomposites were cast on the electrode surface to form aldehyde-terminated composite film that can covalently bind antibody on the film without using other reagent. The immunosensor response was linearly changed with hepatitis B surface antigen concentration in the range from 0.1 to 25 ng ml−1 with a detection limit (signal/noise ratio = 3) of 0.04 ng ml−1. Some important advantages such as simple preparation, good stability, reproducibility, and selectivity of the immunosensor were achieved. 相似文献
7.
Evaluation of antibody immobilization methods for piezoelectric biosensor application 总被引:23,自引:0,他引:23
The immobilization of anti-Salmonella antibodies by two methods were studied and evaluated for their potential use in a piezoelectric biosensor. The optimum temperature-time combinations for the highest immobilization yields were determined for both methods. Protein A binding was found to be 67.4+/-3.8% on the gold surface which then allowed an immobilization of 42.1+/-2.09% antibody. The degree of antibody immobilization via surface aldehyde groups of glutaraldehyde (GA) on a precoated quartz crystal with polyethylenimine (PEI) was 31.6+/-0.3%. A piezoelectric probe was designed and used in dry assays to observe the frequency change due to addition of mass by the immobilization layers. The frequency changes recorded showed a better reproducibility and less added mass for the Protein A method. The frequency decrease due to microg of added antibodies was compared to frequency decrease calculated by the Sauerbrey equation. The experimental data was found to be only approximately 8% of theoretical data. The functionality of the immobilized antibodies with the Protein A method was tested with S. typhimurium in a wet chamber and the frequency decrease was compared to results of a similar system activated with PEI-GA immobilization. The frequency decreases with S. typhimurium concentration of approximately 1.5 x 10(9) CFU/ml were 50+/-2 Hz and 44+/-3 Hz for the Protein A method and PEI-GA method, respectively. It was concluded that although both methods resulted in comparable activities in terms of % immobilized protein and frequency decreases due to Salmonella binding, the Protein A method was favorable due to stability and better reproducibility of the immobilization layers. 相似文献
8.
Protein transduction domain (PTD)-mediated protein delivery into animal cells is a useful technique for regulating cellular functions. Proteins captured by antibodies were delivered into living cells using an antibody/PTD-fused protein A complex. As a model protein, fluorescent-modified antibodies, captured by their respective primary antibody, were analyzed by fluorescence-activated cell sorting (FACS) which showed that the fluorescent-modified antibodies were directly delivered into cells. Peroxidase, captured by its specific antibody, was also delivered into cells and retained its activity. 相似文献
9.
Alsaleem Abdullah Hussain A. Ito Sae Naemura Kiyoshi Muramatsu Hiroshi 《Journal of biological physics》2021,47(2):117-129
Journal of Biological Physics - The characteristics of cultured cell attachment onto poly-l-lysine (PLL), collagen, and the thermoresponsive polymer poly(N-isopropylacrylamide) (PNIPAM) were... 相似文献
10.
Muir BW Barden MC Collett SP Gorse AD Monteiro R Yang L McDougall NA Gould S Maeji NJ 《Analytical biochemistry》2007,363(1):97-107
Using a high-throughput surface discovery approach, we have generated a 1600-member library of metal-containing surfaces and screened them for antibody binding potential. The surface library assembly involved graft modification of argon plasma-treated polyvinylidenedifluoride (PVDF) membranes with alternating maleic anhydride-styrene copolymer followed by anhydride ring opening with a range of secondary amines and microarray contact printing of transition metal complexes. The microarrays of metal-containing surfaces were then tested for their antibody binding capacity by incubation with a biotinylated mouse antibody in a chemiluminescence assay. A total of 11 leads were identified from the first screen, constituting a "hit" rate of 0.7%. A smaller 135-member surface library was then synthesized and screened to optimize existing hits and generate additional leads. To demonstrate the applicability of these surfaces to other formats, high-binding surface leads were then transferred onto Luminex beads for use in a bead flow cytometric immunoassay. The novel one-step antibody coupling process increased assay sensitivity of a Luminex tumor necrosis factor immunoassay. These high-binding surfaces do not require prior incorporation of polyhistidine tags or posttreatments such as oxidation to achieve essentially irreversible binding of immunoglobulin G. 相似文献
11.
励赛琴 《中国微生态学杂志》2017,29(8)
目的 分析与探讨待孕夫妇乙肝表面抗原及乙肝表面抗体检测结果,并研究其对临床孕前检查的影响及评价。方法 随机选取2015‒2017年度在我院进行孕前检查的夫妇2440对(4 880例)为研究对象,按照年度将待孕夫妇分为两组,每组2 440例,两组均加强孕前检查中的乙肝表面抗原(HBsAg)及乙肝表面抗体(HBsAb)的检测。A组为2015年3月‒2016年2月在我院进行乙肝表面抗原及乙肝表面抗体检查的待孕夫妇;B组为2016年3月‒2017年2月在我院进行乙肝表面抗原及乙肝表面抗体检查的待孕夫妇。比较两组待孕夫妇乙肝表面抗原及乙肝表面抗体检测的阳性结果。结果 B组HBsAg阳性率、HBsAb阳性率明显高于A组(6.43% vs 4.63%;62.99% vs 58.44%),差异有统计学意义(P<0.05)。B组、A组男性HBsAg阳性率明显高于同组女性(59.87% vs 40.13%;60.18% vs 39.82%),HBsAb阳性率低于同组女性(46.52% vs 53.48%;47.41% vs 52.59%),差异均有统计学意义(P<0.05)。B组、A组高中及以上学历HBsAg阳性率明显低于同组高中以下学历(38.85% vs 61.95%;38.05% vs 61.15%),高中及以上学历HBsAb阳性率高于同组高中以下学历(53.15% vs 46.84%;51.75% vs 48.25%),差异均有统计学意义(P<0.05)结论 目前夫妇乙肝感染仍处于增高趋势,对于进行孕前检查的待孕夫妇加强乙肝表面抗原及乙肝表面抗体的检测,有助于疾病的早期诊断、干预及治疗,能够减少乙肝传播,可有效降低新生儿乙肝发病率,促进优生优育,提高出生人口整体素质。 相似文献
12.
Mie M Takahashi F Funabashi H Yanagida Y Aizawa M Kobatake E 《Biochemical and biophysical research communications》2003,310(3):730-734
Internalization of antibodies into mammalian cells is a useful method for analyzing and regulating cellular function. In this study, we developed a novel method for the delivery of antibodies into cells using the TAT-fused protein. This fusion protein consists of two functional domains, the protein transduction domain of HIV-1 TAT and the B domain of staphylococcal protein A (SpA), which has an ability to bind to the IgG. The TAT-SpA fusion protein was mixed with fluorescence-labeled rabbit IgG and added to cells. The internalization of antibody was analyzed using confocal microscopy and flow cytometry in living cells. As a result, fluorescence-labeled IgG with the TAT-SpA fusion protein was observed intracellularly. Flow cytometry results demonstrated time course and dose dependence relationships of antibody internalization. These results suggest that the TAT-SpA fusion protein can be a useful reagent for the delivery of antibody into cells. 相似文献
13.
An electrochemical immunosensor was developed for the detection of hepatitis B surface antigen (HBsAg). The biotinylated hepatitis B surface antibody was immobilized on streptavidin magnetic nanoparticles and used for targeting the HBsAg. By the addition of horseradish peroxidase conjugated with secondary antibody (HRP–HBsAb), a sandwich-type immunoassay format was formed. Aminophenol as substrate for conjugated HRP was enzymatically changed into 3-aminophenoxazone (3-APZ). This electroactive enzymatic production (3-APZ) was transferred into an electrochemical cell and monitored by cyclic voltammetry. Under optimal conditions, the cathodic current response of 3-APZ, which was proportional to the HBsAg concentration, was measured by a glassy carbon electrode. The immunosensor response was linear toward HBsAg in the concentration range from 0.001 to 0.015 ng/ml with a detection limit of 0.9 pg/ml at a signal/noise ratio of 3. 相似文献
14.
María González-González Raquel Bartolome Ricardo Jara-Acevedo Juan Casado-Vela Noelia Dasilva Sergio Matarraz Jacinto García J.A. Alcazar J.M. Sayagues Alberto Orfao Manuel Fuentes 《Analytical biochemistry》2014
Antibody arrays hold great promise for biomedical applications, but they are typically manufactured using chemically functionalized surfaces that still require optimization. Here, we describe novel hetero-functionally activated glass surfaces favoring oriented antibody binding for improved performance in protein microarray applications. Antibody arrays manufactured in our facility using the functionalization chemistries described here proved to be reproducible and stable and also showed good signal intensities. As a proof-of-principle of the glass surface functionalization protocols described in this article, we built antibody-based arrays functionalized with different chemistries that enabled the simultaneous detection of 71 human leukocyte membrane differentiation antigens commonly found in peripheral blood mononuclear cells. Such detection is specific and semi-quantitative and can be performed in a single assay under native conditions. In summary, the protocol described here, based on the use of antibody array technology, enabled the concurrent detection of a set of membrane proteins under native conditions in a specific, selective, and semi-quantitative manner and in a single assay. 相似文献
15.
The photo-immobilization technique is useful for immobilization of various biomolecules on assorted material surfaces, independent of the organic functional groups that may be present. Here, we report a convenient new photo-immobilization technique that was developed by combining a nonbiofouling polymer containing polyethylene glycol and a photoreactive crosslinker for surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) measurements. By this method, nonspecific interactions were reduced and various types of molecules, bovine serum albumin, heparin, dsDNA, phosphatidylserine, Tobacco Mosaic Virus, and norfloxacine, were immobilized on an alkane thiol-modified gold surface by a single method. The interactions of photo-immobilized biomolecules and their corresponding antibodies were investigated by SPR and QCM. In addition, SPR imaging was possible using the present method. 相似文献
16.
We present a new type of enzyme-antibody conjugate that simplifies the labeling procedure and increases the sensitivity of enzyme-linked immunosorbent assay (ELISA). The conjugates were prepared through layer-by-layer immobilization of enzyme and antibody on a silica nanoparticle scaffold. A maximal amount of enzyme was immobilized on the nanoparticle, followed by antibody linkage through Dextran 500. The conjugate could be easily purified from unreacted reagents by simple centrifugations. In comparison with the conventional antibody-enzyme conjugate used in ELISA, which often has one or two enzyme molecules per antibody, the new type of conjugate contained more enzyme molecules per antibody and provided a much higher signal and increased sensitivity. When used in an ELISA detection of the hepatitis B surface antigen (HBsAg), the detection limit was three times lower than that of the commercially available ELISA kit. 相似文献
17.
Leyva A Hernández N González T Sánchez JC Franco A Delgado I Montañez M Valdés R 《Biochemical and biophysical research communications》2004,325(4):1438-1442
Immunopurification is one of the most effective chromatography steps to purify the hepatitis B surface antigen, which have successfully been used as an active pharmaceutical ingredient of hepatitis B vaccines. Plant-derived antibodies could be an appropriated ligand for such purposes because plants are the most cost-effective production systems and have the additional advantage that plant viruses cannot infect humans. In this work, a polyclonal antibody alkaline phosphatase-linked immunoassay was standardized and validated to quantify a plant-derived antibody directed against the HBsAg. The validation of an immunoassay to quantify plantibodies is a relatively complex task due to the complexity of the plant extract, the low level of expression of this molecule, and the potential interferences of endogenous peroxidases contributed by plants. These results allow estimating the plant-derived antibody concentration up to 3.81 ng/mL with high specificity, precision, and repeatability. The working range of the standard curve was between 3.81 and 60 ng/mL, and the intra- and inter-variation coefficients were between 10% and 20% in a production process's sample dependent way. This enzyme-linked immunosorbent assay is considered valuable to improve the design of the purification process and also to obtain a better estimation of the antibody expression level and process's recovery. 相似文献
18.
Martina C. C. Pinto Stefanni S. Everton Leilane C. M. Cirilo Thalita N. de Melo Eliane P. Cipolatti Evelin A. Manoel 《Biocatalysis and Biotransformation》2020,38(4):304-314
AbstractMany studies describe the advantages of using hydrophobic particles on lipase immobilisation. However, many of these works neglect the effect of other variables of the supports, such as specific area and porosity, on the biocatalyst performance, and do not evaluate the influence of the hydrophobicity level of the particles on the biocatalysts’ activity as a single variable. Thus, the focus of the present work was to evaluate the effect of the hydrophobicity degree of polymeric particles on the biocatalysts’ activities, mitigating the influence of other variables. The study was divided into two steps. Firstly, distinct particles, exhibiting different composition and hydrophobicity levels, were used for the immobilization of a commercial lipase B from Candida antarctica (CAL-B). Then, distinct core-shell polymeric particles presenting different functional compounds on the surface were produced, using as comonomers styrene, divinylbenzene, 1-octene, vinylbenzoate and cardanol. Such particles were subsequently used for CAL-B immobilisation and the performance of the biocatalysts was evaluated on hydrolysis (using p-nitrophenyl laurate, as substrate) and esterification (using ethanol and oleic acid, as substrate) reactions. Based on the screening step, it was observed that for non-porous particles the correlation coefficients between the hydrophobicity level of the supports and the biocatalysts performance, for both hydrolysis and esterification reactions, were very low (0.32 and 0.45, respectively). It highlights that there was no significant correlation between these variables and that, probably, the chemical composition of the polymeric chains affects more significantly the biocatalyst performance. Then, analysing the subsequent stage, it was observed that small changes in the surface composition of the core-shell particles result in significant changes on the textural properties of the supports (specific area ranging from 1.2?m2.g?1 to 18.3?m2.g?1; and contact angles ranging from 71° (hydrophilic particles) to 92° (hydrophobic supports) when polymer films were put in contact with water). Such particles were also employed on CAL-B immobilization and it was noticed that higher correlation coefficients were achieved for hydrolysis (ρ?=?0.53) and esterification (ρ?=?0.74) reactions. Therefore, it is shown that the hydrophobicity degree of such supports starts to affect more effectively the biocatalysts performance when other textural features of the supports become more significant, such as specific area and porosity. 相似文献
19.
A chemiluminescent assay for hepatitis-B surface antigen is described which used an isoluminol derivative as the label. The assay is precise intra-assay CV, 1.96-2.45%; inter-assay CV, 5.26-8.11% and has a lower detection limit for hepatitis-B surface antigen of 1.3U/I. 相似文献
20.
Woochang Lee Doo-Bong Lee Byung-Keun Oh Won Hong Lee Jeong-Woo Choi 《Enzyme and microbial technology》2004,35(6-7):678-682
The fabrication of protein A film on self-assembled monolayer was done for the construction of immunosensor using surface plasmon resonance (SPR) measurement. The layer of heterobifunctional linker, N-succinimidyl-3-(2-pyridyldithio)propionate (SPDP) was self-assembled on the gold (Au) surface. Due to the succinimidyl functional group in SPDP to be reacted with amine (NH2) group of protein A, the covalent immobilization of protein A was subsequently induced toward Au surface. The characteristics of film formation were investigated using SPR with respect to the various concentrations of SPDP and protein A. The optimal concentration for the film formation was found to be 0.1 mg/mL of SPDP and 0.1 mg/mL of protein A, respectively. The surface topography of protein A layer using atomic force microscopy showed that the heteromolecular layer was formed successfully. The antibody, anti-bovine serum albumin (BSA), was immobilized onto protein A layer, and the fabricated antibody layer was applied for the detection of BSA. The extent of BSA–antibody binding was measured using SPR and its lower detection limit of BSA was 100 pM. 相似文献