首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An enzyme-linked immunofiltration assay (ELIFA) and a microtitre plate enzyme-linked immunosorbent assay (ELISA) were developed and compared for their ability to detect staphylococcal enterotoxin B (SEB). The double antibody capture format was used for both assays. Factors which improved the sensitivity of the ELIFA system were (1) addition of casein and thimerosal to the antigen dilution buffer; (2) addition of polyethylene glycol (MW 6000) to the detection and conjugate antibody dilution buffers; and (3) washing with diethanolamine buffer prior to addition of the substrate/chromogen. The ELIFA system had a turnaround time of approximately 1 h and a detection limit of 1 ng/mL of purified SEB. The ELISA had a total turnaround time of 21 h, or 3 h using plates pre-coated overnight with the capture antibody. The detection limit of the ELISA for purified SEB was 0.05 ng/mL. The detection limit of SEB in cheese samples spiked with purified enterotoxin and subjected to a simple extraction procedure was 1 ng/mL and 0.1 ng/mL of extract, with the ELIFA and the ELISA, respectively.  相似文献   

2.
One of the great challenges in science and engineering today is to develop technologies to improve the health of people in the poorest regions of the world. Here we integrated new procedures for manufacturing, fluid handling and signal detection in microfluidics into a single, easy-to-use point-of-care (POC) assay that faithfully replicates all steps of ELISA, at a lower total material cost. We performed this 'mChip' assay in Rwanda on hundreds of locally collected human samples. The chip had excellent performance in the diagnosis of HIV using only 1 μl of unprocessed whole blood and an ability to simultaneously diagnose HIV and syphilis with sensitivities and specificities that rival those of reference benchtop assays. Unlike most current rapid tests, the mChip test does not require user interpretation of the signal. Overall, we demonstrate an integrated strategy for miniaturizing complex laboratory assays using microfluidics and nanoparticles to enable POC diagnostics and early detection of infectious diseases in remote settings.  相似文献   

3.
A fluorescence-based biosensor has been developed for simultaneous analysis of multiple samples for multiple biohazardous agents. A patterned array of antibodies immobilized on the surface of a planar waveguide is used to capture antigen present in samples; bound analyte is then quantified by means of fluorescent tracer antibodies. Upon excitation of the fluorophore by a small diode laser, a CCD camera detects the pattern of fluorescent antibody:antigen complexes on the waveguide surface. Image analysis software correlates the position of fluorescent signals with the identity of the analyte. This array biosensor has been used to detect toxins, toxoids, and killed or non-pathogenic (vaccine) strains of pathogenic bacteria. Limits of detection in the mid-ng/ml range (toxins and toxoids) and in the 10(3)-10(6) cfu/ml range (bacterial analytes) were achieved with a facile 14-min off-line assay. In addition, a fluidics and imaging system has been developed which allows automated detection of staphylococcal enterotoxin B (SEB) in the low ng/ml range.  相似文献   

4.
A dot blot hybridization technique with oligonucleotide probes was developed for the specific detection of the TSST-1 gene and the staphylococcal enterotoxin (SE) genes A, B, C, D and E. For each toxin gene a probe sequence was chosen from the previously determined sequence. A total of 145 staphylococcal strains (133 Staphylococcus aureus and 12 coagulase-negative staphylococci (CNS) were studied by this genotypic method and by two phenotypic assays (gel immunodiffusion and ELISA). An excellent correlation (96%) was observed between the genotypic and phenotypic assays. DNA from two CNS strains hybridized with a probe without detection of the corresponding toxin (SEB for one strain and SEC for the other strain). One Staph. aureus strain was shown to be an SEC producer, but was not detected by the corresponding probe. Gene probe and immunological assays seem to be complementary methods for studies of staphylococcal strains producing (or potentially producing) TSST-1 or enterotoxins.  相似文献   

5.
B. JAULHAC, M. BES, N. BORNSTEIN, Y. PIÉMONTY. BRUN AND J. FLEURETTE. 1992. A dot blot hybridization technique with oligonucleotide probes was developed for the specific detection of the TSST-1 gene and the staphylococcal enterotoxin (SE) genes A, B, C, D and E. For each toxin gene a probe sequence was chosen from the previously determined sequence. A total of 145 staphylococcal strains (133 Staphylococcus aureus and 12 coagulase-negative staphylococci (CNS)) were studied by this genotypic method and by two phenotypic assays (gel immunodiffusion and ELISA). An excellent correlation (96%) was observed between the genotypic and phenotypic assays. DNA from two CNS strains hybridized with a probe without detection of the corresponding toxin (SEB for one strain and SEC for the other strain). One Staph. aureus strain was shown to be an SEC producer, but was not detected by the corresponding probe. Gene probe and immunological assays seem to be complementary methods for studies of staphylococcal strains producing (or potentially producing) TSST-1 or enterotoxins.  相似文献   

6.
Staphylococcal food poisoning (SFP) is one of the most prevalent causes of food-borne illness throughout the world. SFP is caused by 21 different types of staphylococcal enterotoxins produced by Staphylococcus aureus. Among these, staphylococcal enterotoxin B (SEB) is the most potent toxin and is a listed biological warfare (BW) agent. Therefore, development of immunological reagents for detection of SEB is of the utmost importance. High-affinity and specific monoclonal antibodies are being used for detection of SEB, but hybridoma clones tend to lose their antibody-secreting ability over time. This problem can be overcome by the use of recombinant antibodies produced in a bacterial system. In the present investigation, genes from a hybridoma clone encoding monoclonal antibody against SEB were immortalized using antibody phage display technology. A murine phage display library containing single-chain variable-fragment (ScFv) antibody genes was constructed in a pCANTAB 5E phagemid vector. Phage particles displaying ScFv were rescued by reinfection of helper phage followed by four rounds of biopanning for selection of SEB binding ScFv antibody fragments by using phage enzyme-linked immunosorbent assay (ELISA). Soluble SEB-ScFv antibodies were characterized from one of the clones showing high affinity for SEB. The anti-SEB ScFv antibody was highly specific, and its affinity constant was 3.16 nM as determined by surface plasmon resonance (SPR). These results demonstrate that the recombinant antibody constructed by immortalizing the antibody genes from a hybridoma clone is useful for immunodetection of SEB.  相似文献   

7.
8.
Staphylococcal enterotoxins (SEs) are the second most common causal agents of food poisoning throughout the world. Staphylococcal enterotoxin B (SEB) is one of the most potent and a listed biological warfare agent. Therefore, its quick, accurate and sensitive detection is of paramount importance. But availability of sensitive and specific antibodies against SEB is the major bottleneck in the development of an immunodetection system. Therefore, in the present study seb gene was cloned and expressed in a heterologous host resulting in a yield of 92 mg pure toxin per litre of culture broth after Ni–NTA affinity purification. Antibodies raised against the recombinant toxin did not cross react with related enterotoxins and organisms that can gain access in the food. Further, a sandwich ELISA was developed to detect SEB after extraction from artificially spiked food samples like milk, orange juice, skim milk and khoya. The sandwich ELISA was able to detect SEB in the range of 0.25 to 0.49 ng/ml or g of food. The detection system developed in the present study is at least as specific and sensitive as other commercially available kits which use monoclonal antibodies.  相似文献   

9.
A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay consisted of immunocapture of SEB and real-time PCR amplification of the DNA probe linked to the detection antibody. iqPCR was compared to an in-house enzyme-linked immunosorbent assay (ELISA) using the same couple of capture-detection antibodies and to commercial kits for detection of S. aureus enterotoxins (SE). The iqPCR was approximately 1,000 times more sensitive (<10 pg ml(-1)) than the in-house ELISA and had a dynamic range of approximately 10 pg ml(-1) to approximately 30,000 pg ml(-1). iqPCR was not inhibited by any of the foods tested and was able to detect SEB present in these foods. No cross-reactivity with SE other than SEB was observed. Application of iqPCR for detection of SEB in cultures of S. aureus revealed the onset of SEB production after 4 h of incubation at 22, 37, and 42 degrees C, which was in the first half of the exponential growth phase. The total amounts of SEB produced by the two strains tested were larger at 42 degrees C than at 37 degrees C and were strain dependent.  相似文献   

10.

Introduction

Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the “EID cascade” is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy.

Methods

We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results.

Results

Overall, 1098 children with a median age of 47 days (IQR, 42–117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6–14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7–97.9%) and a specificity of 99.8% (95% CI, 99.1–100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4–98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04).

Conclusion

Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.  相似文献   

11.
We describe an apparatus for measuring signals emanated from two heterogeneous chemiluminescence immunoassay (CLIA) configurations: antibody-coated polystyrene beads, in reaction tray wells, and microparticles captured by a porous matrix. An optics and fluidics design which allows the use of a common detection head for these two different assay configurations is described. The detection head moves along three Cartesian coordinates to create a localized light-tight compartment around each individual disposable reaction vessel. Reproducibility of the light seal, trigger solution delivery, and mixing is achieved for acridinium-labeled CLIA. The coated polystyrene beads configuration is tested using beta HCG, CEA, and TSH assays. The microparticle-capture configuration is tested using beta HCG and HBsAg assays. The microparticle capture CLIA has shorter incubation times and the potential for ease of automation.  相似文献   

12.
A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay consisted of immunocapture of SEB and real-time PCR amplification of the DNA probe linked to the detection antibody. iqPCR was compared to an in-house enzyme-linked immunosorbent assay (ELISA) using the same couple of capture-detection antibodies and to commercial kits for detection of S. aureus enterotoxins (SE). The iqPCR was approximately 1,000 times more sensitive (<10 pg ml−1) than the in-house ELISA and had a dynamic range of approximately 10 pg ml−1 to approximately 30,000 pg ml−1. iqPCR was not inhibited by any of the foods tested and was able to detect SEB present in these foods. No cross-reactivity with SE other than SEB was observed. Application of iqPCR for detection of SEB in cultures of S. aureus revealed the onset of SEB production after 4 h of incubation at 22, 37, and 42°C, which was in the first half of the exponential growth phase. The total amounts of SEB produced by the two strains tested were larger at 42°C than at 37°C and were strain dependent.  相似文献   

13.
Infectious diseases such as HIV-1/AIDS, tuberculosis (TB), hepatitis B (HBV), and malaria still exert a tremendous health burden on the developing world, requiring rapid, simple and inexpensive diagnostics for on-site diagnosis and treatment monitoring. However, traditional diagnostic methods such as nucleic acid tests (NATs) and enzyme linked immunosorbent assays (ELISA) cannot be readily implemented in point-of-care (POC) settings. Recently, plasmonic-based biosensors have emerged, offering an attractive solution to manage infectious diseases in the developing world since they can achieve rapid, real-time and label-free detection of various pathogenic biomarkers. Via the principle of plasmonic-based optical detection, a variety of biosensing technologies such as surface plasmon resonance (SPR), localized surface plasmon resonance (LSPR), colorimetric plasmonic assays, and surface enhanced Raman spectroscopy (SERS) have emerged for early diagnosis of HIV-1, TB, HBV and malaria. Similarly, plasmonic-based colorimetric assays have also been developed with the capability of multiplexing and cellphone integration, which is well suited for POC testing in the developing world. Herein, we present a comprehensive review on recent advances in surface chemistry, substrate fabrication, and microfluidic integration for the development of plasmonic-based biosensors, aiming at rapid management of infectious diseases at the POC, and thus improving global health.  相似文献   

14.
川西沿海拔梯度典型植被类型土壤活性有机碳分布   总被引:11,自引:0,他引:11  
研究土壤活性有机碳含量及分配比例是揭示土壤碳库周转及调控机理的重要途径,通过利用高锰酸钾氧化法获得易氧化有机碳、湿筛法获得颗粒有机碳和密度分离法获得轻组有机碳3项指标探讨沿海拔梯度不同植被类型间(山地常绿阔叶林、常绿落叶阔叶混交林、落叶阔叶林、针阔混交林、暗针叶林)土壤活性有机碳含量差异及调控因子,结果表明:随土层加深,土壤颗粒和轻组有机碳含量及分配比例均降低,土壤易氧化有机碳含量降低而分配比例保持较稳定水平。高海拔植被类型具有较高的土壤活性有机碳含量和分配比例。不同活性有机碳含量之间均呈显著线性相关(P0.05)表明活性有机碳起源的类似。活性有机碳与土壤粘粒+粉粒含量百分比呈显著负相关(P0.05)表明活性有机碳趋向分布于土壤大团聚体当中。年均温与不同植被类型间表层土壤活性有机碳含量和分配比例成负相关趋势,但可能由于取样点较少的缘故而在统计上不显著。年均温与土壤非保护性有机碳向保护性有机碳的转化速率常数(K)接近于显著负相关(P=0.062)。  相似文献   

15.
Specific viral laboratory diagnosis of primary Epstein-Barr Virus (EBV) infection is usually based on antibody-detection assays. However, molecular detection is also considered the reference standard assay for diagnosis of central nervous system infections and of most cases of nasopharyngeal carcinoma (NPC). One-step or nested polymerase chain reaction (PCR) has rapidly replaced immunological assays based on virus-specific Ig antibodies for the laboratory diagnosis of Herpesvirus infections, even if serological methods are considered an additional tool for defining clinical diagnosis. In this article, we will present a rapid, sensitive and robust molecular tool for the viral detection of EBV (EBNA-1) within tissue specimens by making use of in situ PCR (IS-PCR).  相似文献   

16.
Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays (ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in anti-Ebola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G (IgG) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA’s ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.  相似文献   

17.
Design and demonstration of an automated cell-based biosensor.   总被引:4,自引:0,他引:4  
Cell-based biosensors have the capacity to respond to a wide range of analytes in a physiologically relevant manner and appear well-suited for toxicity monitoring of both known and unknown analytes. One means of acquiring cellular functional information for biosensor applications involves extracellular recording from excitable cells, which can generate noninvasive and long-term measurements. Previous work from our laboratory described a prototype portable system capable of high signal-to-noise extracellular recordings, in spite of deficiencies in thermal control, fluidics handling, and absence of data acquisition (DAQ) capability. The present work describes a cell-based biosensor system that incorporates low noise amplifier and filter boards, a two-stage thermal control system with integrated fluidics and a flexible graphical user interface for DAQ and control implemented on a personal computer. Wherever possible, commercial off-the-shelf components have been utilized for system design and fabrication. The system exhibits input-referred noise levels of 5-10 microV(RMS), such that extracellular potentials exceeding 50-60 microV can be readily resolved. In addition, the biosensor system is capable of automated temperature and fluidics control. Flow rates can range from 0-2.5 ml/min, while the cell recording chamber temperature is maintained within a range of 36-37 degrees C. To demonstrate the capability of this system to resolve small extracellular potentials, recordings from embryonic chick cardiac myocytes have been performed.  相似文献   

18.
An improved ELISA method for the detection of Staphylococcal Enterotoxin B (SEB) in protein A preparations is presented. Fab fragments were obtained by digestion with papain of anti-SEB IgG bound to SEB immobilized on Sepharose 4B. Anti-SEB and peroxidase-labeled Fab fragments from secondary antibodies were successfully used in a modified ELISA of SEB in protein A preparations. SEB-Sepharose was used repeatedly for the production of anti-SEB Fab fragments by papain digestion without loss of affinity. In addition, for the purification of SEB from crude culture filtrates, an initial step utilizing a combined heat and pH treatment for the removal of significant amounts of contaminating proteins without losses of toxin activity is presented. This pretreatment step yielded positive effects in further downstream processing considering both shortened time and an increase in total recovery.  相似文献   

19.
Staphylococcus aureus are potent human pathogens possessing arsenal of virulence factors. Staphylococcal food poisoning (SFP) and respiratory infections mediated by staphylococcal enterotoxin B (SEB) are common clinical manifestations. Many diagnostic techniques are based on serological detection and quantification of SEB in different food and clinical samples. Aptamers are known as new therapeutic and detection tools which are available in different ssDNA, dsDNA and protein structures. In this study, we used a new set of ssDNA aptamers against SEB. The methods used included preparation of a dsDNA library using standard SEB protein as the target analyte, affinity chromatography matrix in microfuge tubes, SELEX procedures to isolate specific ssDNA‐aptamer as an affinity ligand, aptamer purification using ethanol precipitation method, affinity binding assay using ELISA, aptamer cloning and specificity test. Among 12 readable sequences, three of them were selected as the most appropriate aptamer because of their affinity and specificity to SEB. This study presents a new set of ssDNA aptamer with favorable selectivity to SEB through 12 rounds of SELEX. Selected aptamers were used to detect SEB in infected serum samples. Results showed that SEB c1 aptamer (2 µg SEB/100 nM aptamer) had favorable specificity to SEB (kd = 2.3 × 10?11). In conclusion, aptamers can be considered as useful tools for detecting and evaluating SEB. The results showed that affinity chromatography was an affordable assay with acceptable accuracy to isolate sensitive and selective novel aptamers. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
HIV-1 integrase, an essential enzyme for retroviral replication, is a validated target for anti-HIV therapy development. The catalytic core domain of integrase (IN–CCD) is capable of catalyzing disintegration reaction. In this work, a hairpin-shaped disintegration substrate was designed and validated by enzyme-linked immunosorbent assay; a molecular beacon-based assay was developed for disintegration reaction of IN–CCD. Results showed that the disintegration substrate could be recognized and catalyzed by IN–CCD, and the disintegration reaction can be monitored according to the increase of fluorescent signal. The assay can be applied to real-time detection of disintegration with advantages of simplicity, high sensitivity, and excellent specificity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号