首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Activated factor XIII (FXIIIa) catalyzes the formation of γ-glutamyl-ε-lysyl cross-links within the fibrin blood clot network. Although several cross-linking targets have been identified, the characteristic features that define FXIIIa substrate specificity are not well understood. To learn more about how FXIIIa selects its targets, a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS)-based assay was developed that could directly follow the consumption of a glutamine-containing substrate and the formation of a cross-linked product with glycine ethylester. This FXIIIa kinetic assay is no longer reliant on a secondary coupled reaction, on substrate labeling, or on detecting only the final deacylation portion of the transglutaminase reaction. With the MALDI–TOF MS assay, glutamine-containing peptides derived from α2-antiplasmin, Staphylococcus aureus fibronectin binding protein A, and thrombin-activatable fibrinolysis inhibitor were examined directly. Results suggest that the FXIIIa active site surface responds to changes in substrate residues following the reactive glutamine. The P−1 substrate position is sensitive to charge character, and the P−2 and P−3 substrate positions are sensitive to the broad FXIIIa substrate specificity pockets. The more distant P−8 to P−11 region serves as a secondary substrate anchoring point. New knowledge on FXIIIa specificity may be used to design better substrates or inhibitors of this transglutaminase.  相似文献   

2.
Microarrays of peptide and recombinant protein libraries are routinely used for high-throughput studies of protein–protein interactions and enzymatic activities. Imaging mass spectrometry (IMS) is currently applied as a method to localize analytes on thin tissue sections and other surfaces. Here, we have applied IMS as a label-free means to analyze protein–peptide interactions in a microarray-based phosphatase assay. This IMS strategy visualizes the entire microarray in one composite image by collecting a predefined raster of matrix-assisted laser desorption/ionization time-of-flight (MALDI–TOF) mass spectrometry spectra over the surface of the chip. Examining the bacterial tyrosine phosphatase YopH, we used IMS as a label-free means to visualize enzyme binding and activity with a microarrayed phosphopeptide library printed on chips coated with either gold or indium–tin oxide. Furthermore, we demonstrate that microarray-based IMS can be coupled with surface plasmon resonance imaging to add kinetic analyses to measured binding interactions. The method described here is within the capabilities of many modern MALDI–TOF instruments and has general utility for the label-free analysis of microarray assays.  相似文献   

3.
Large neutral amino acid transporter 1 (LAT1) transports neutral amino acids with aromatic or branched side chains as well as their derivatives or prodrugs. Because the transporter is highly expressed at the blood–brain barrier and in some tumor cells, it is a potential target to treat brain disease and cancer. Therefore, it is essential to develop a method to screen for LAT1 inhibitors or for therapeutic compounds that it can transport. In this study, one such method was developed that combines an in vitro cell-based assay with high-throughput ultra-performance liquid chromatography triple quadrupole mass spectrometry (UPLC–QQQ–MS). Using this method, candidate compounds could be tested for the ability to inhibit or to compete with uptake of gabapentin, an LAT1 substrate, in HT-29 cells, which abundantly express the transporter. Gabapentin uptake is measured by mass spectrometry, which requires as little as 6 min/sample and will enable analysis of large numbers of samples. We anticipate that the method will be useful to identify LAT1 inhibitors or substrates without the need for animals or radioactive labeling.  相似文献   

4.
A simple, small-scale, and high-throughput method for preparation of plant N-glycans for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS) is described. This method entailed the extraction of soluble proteins, pepsin digestion, release of N-glycans by glycopeptidase A, and a three-step chromatographic purification process using cation exchange, anion exchange, and graphitized carbon. Homemade minicolumns using commercially available filter unit devices were used for N-glycan purification steps. All purification steps were designed to be easy. Using this method, N-glycans from 10-mg leaf samples of different plant species and only 2 μg of pure horseradish peroxidase were successfully purified.  相似文献   

5.
The serine hydrolase monoacylglycerol lipase (MGL) modulates endocannabinoid signaling in vivo by inactivating 2-arachidonoylglycerol (2-AG), the main endogenous agonist for central CB1 and peripheral CB2 cannabinoid receptors. To characterize this key endocannabinoid enzyme by mass spectrometry-based proteomics, we first overexpressed recombinant hexa-histidine-tagged human MGL (hMGL) in Escherichia coli and purified it in a single chromatographic step with high yield (approximately 30 mg/L). With 2-AG as substrate, hMGL displayed an apparent V max of 25 micromol/(microg min) and K m of 19.7 microM, an affinity for 2-AG similar to that of native rat-brain MGL (rMGL) (Km=33.6 microM). hMGL also demonstrated a comparable affinity (Km approximately 8-9 microM) for the novel fluorogenic substrate, arachidonoyl, 7-hydroxy-6-methoxy-4-methylcoumarin ester (AHMMCE), in a sensitive, high-throughput fluorometric MGL assay. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) unequivocably demonstrated the mass (34,126 Da) and purity of this hMGL preparation. After in-solution tryptic digestion, hMGL full proteomic characterization was carried out, which showed (1) an absence of intramolecular disulfide bridges in the functional, recombinant enzyme and (2) the post-translational removal of the enzyme's N-terminal methionine. Availability of sufficient quantities of pure, well-characterized hMGL will enable further molecular and structural profiling of this key endocannabinoid-system enzyme.  相似文献   

6.
Genomic DNA for a class IV chitinase was cloned from yam (Dioscorea opposita Thunb) leaves and sequenced. The deduced amino acid sequence shows 50 to 59% identity to class IV chitinases from other plants. The yam chitinase, however, has an additional sequence of 8 amino acids (a C-terminal extension) following the cysteine that was reported as the last amino acid for other class IV chitinases; this extension is perhaps involved in subcellular localization. A homology model based on the structure of a class II chitinase from barley was used as an aid to interpreting the available data. The analysis suggests that the class IV enzyme recognizes an even shorter segment of the substrate than class I or II enzymes. This observation might help to explain why class IV enzymes are better suited to attack against pathogen cell walls.  相似文献   

7.
Botulinum neurotoxins (BoNTs) are the most toxic substances known to humankind. Rapid and sensitive detection of BoNTs is necessary for timely clinical confirmation of the disease state in botulism. BoNTs cleave proteins and peptide mimics at specific sites. A mass spectrometry (MS)-based method, Endopep–MS, can detect these cleavages and has detection limits of 0.05–0.5 mouse LD50 (U) in serum, depending on the BoNT serotypes. In this method, the products generated from cleavage of peptide substrates using antibody affinity-purified toxins are detected by MS. Nonspecific bound endogenous proteases or peptidases in stool can coextract with the toxin, cleaving the peptide substrates and reducing the sensitivity of the method. Here we report a method to reduce nonspecific substrate cleavage by reducing stool protease coextraction in the Endopep–MS assay.  相似文献   

8.
Genomic DNA for a class IV chitinase was cloned from yam (Dioscorea opposita Thunb) leaves and sequenced. The deduced amino acid sequence shows 50 to 59% identity to class IV chitinases from other plants. The yam chitinase, however, has an additional sequence of 8 amino acids (a C-terminal extension) following the cysteine that was reported as the last amino acid for other class IV chitinases; this extension is perhaps involved in subcellular localization. A homology model based on the structure of a class II chitinase from barley was used as an aid to interpreting the available data. The analysis suggests that the class IV enzyme recognizes an even shorter segment of the substrate than class I or II enzymes. This observation might help to explain why class IV enzymes are better suited to attack against pathogen cell walls.  相似文献   

9.
Short tandem repeat (STR) loci are routinely analyzed by capillary electrophoresis. However, this method has several disadvantages, including long operational time, low throughput, and inaccuracy. As a result of the introduction of matrix-associated laser desorption/ionization time-of-flight (MALDI–TOF) and electrospray ionization (ESI), mass spectrometry has become an alternative method for genotyping polymorphic STR loci. Here we established a restriction fragment mass polymorphism (RFMP) assay for genotyping STR locus, TPOX, by typeIIS restriction endonuclease cleavage of polymerase chain reaction (PCR) amplicon followed by MALDI–TOF mass spectrometry. The resulting TPOX genotypes from this assay were in good agreement with the results from direct DNA sequencing and GeneScan assays. Our results showed that the RFMP assay is an accurate and high-throughput method for analyzing long DNA fragments such as STR markers. Further research with multiple STR loci may allow this assay to be used for diverse applications such as forensics, paternity tests, and detection of genetic disorders.  相似文献   

10.
We have developed a method for intact mass analysis of detergent-solubilized and purified integral membrane proteins using liquid chromatography–mass spectrometry (LC–MS) with methanol as the organic mobile phase. Membrane proteins and detergents are separated chromatographically during the isocratic stage of the gradient profile from a 150-mm C3 reversed-phase column. The mass accuracy is comparable to standard methods employed for soluble proteins; the sensitivity is 10-fold lower, requiring 0.2–5 μg of protein. The method is also compatible with our standard LC–MS method used for intact mass analysis of soluble proteins and may therefore be applied on a multiuser instrument or in a high-throughput environment.  相似文献   

11.
Narayanan R  LeDuc B  Williams DA 《Life sciences》2004,74(20):2527-2539
The purposes of this study were to develop a HPLC method to assay for haloperidol glucuronide (HALG); to apply this assay method to the in vitro determination of haloperidol (HAL) UDP-glucuronosyltransferase (UGT) enzyme kinetics in rat liver microsomes (RLM); and to identify the UGT isoforms catalyzing glucuronidation of HAL in rats. Incubation of Brij-activated RLM with HAL and UDP-glucuronic acid (UDPGA) in TRIS pH 7.4 buffer resulted in the formation of a single peak in the HPLC chromatogram at 270 nm. The identity of this peak was confirmed to be that of HALG by 1) β-glucuronidase hydrolysis; 2) incubation without UDPGA; 3) UV spectral analysis; and 4) LC/MS/MS to yield the expected mass of 552.1. Enzyme kinetic studies using single enzyme Michaelis-Menton model showed an apparent Vmax = 271.9 ± 10.1 pmoles min−1 mg protein−1 and Km = 61 ± 7.2 μM. Glucuronidation activity in homozygous Gunn (j/j) rats was approximately 80% as compared to Sprague-Dawley RLM. HALG formation was approximately doubled in PB-induced RLM. There was no increase in glucuronidation activities in 3MC-induced RLM. The Gunn rat and the PB-induced RLM data suggest predominant but not exclusive involvement of the UGT2B family in the formation of HALG. Because the UGTs exhibit overlapping substrate specificities and most substrates are glucuronidated by more than one isoform, inhibition studies with UGT2B1 substrate probe testosterone and the UGT2B12 substrate probe borneol were conducted. UGT2B1 and UGT2B12 exhibited 40% and 90% inhibition of HAL glucuronidation, respectively. Thus, UGT2B12 and UGT 2B1 isoforms are responsible for catalyzing HAL glucuronidation in rats. Our HPLC assay provides a specific and sensitive technique for the measurement of in vitro HAL-UGT activity.  相似文献   

12.
The determination of kinetic parameters of chitinases using natural substrates is difficult due to low K(m) values, which require the use of low substrate concentrations that are hard to measure. Using the natural substrate (GlcNAc)(4), we have developed an assay for the determination of k(cat) and K(m)values of chitinases. Product concentrations as low as 0.5 microM were detected using normal-phase high-performance liquid chromatography (HPLC) with an amide 80 column (0.20 x 25 cm) using spectrophotometric detection at 210 nm. By means of this assay, k(cat) and K(m)values for chitinases A (ChiA) and B (ChiB) of Serratia marcescens were found to be 33+/-1s(-1) and 9+/-1 microM and 28+/-2s(-1) and 4+/-2 microM, respectively. For ChiB, these values were compared to those found with commonly used substrates where the leaving group is a (nonnatural) chromophore, revealing considerable differences. For example, assays with 4-methylumbelliferyl-(GlcNAc)(2) yielded a k(cat) value of 18+/-2s(-1) and a K(m) value of 30+/-6 microM. For two ChiB mutants containing a Trp --> Ala mutation in the +1 or +2 subsites, the natural substrate and the 4-methylumbelliferyl-(GlcNAc)(2) assays yielded rather similar K(m) values (5-fold difference at most) but showed dramatic differences in k(cat) values (up to 90-fold). These results illustrate the risk of using artificial substrates for characterization of chitinases and, thus, show that the new HPLC-based assay is a valuable tool for future chitinase research.  相似文献   

13.
Lipoxygenases (LOXs) regulate inflammation through the production of a variety of molecules whose specific downstream effects are not entirely understood due to the complexity of the inflammation pathway. The generation of these biomolecules can potentially be inhibited and/or allosterically regulated by small synthetic molecules. The current work describes the first mass spectrometric high-throughput method for identifying small molecule LOX inhibitors and LOX allosteric effectors that change the substrate preference of human lipoxygenase enzymes. Using a volatile buffer and an acid-labile detergent, enzymatic products can be directly detected using high-performance liquid chromatography–mass spectrometry (HPLC–MS) without the need for organic extraction. The method also reduces the required enzyme concentration compared with traditional ultraviolet (UV) absorbance methods by approximately 30-fold, allowing accurate binding affinity measurements for inhibitors with nanomolar affinity. The procedure was validated using known LOX inhibitors and the allosteric effector 13(S)-hydroxy-9Z,11E-octadecadienoic acid (13-HODE).  相似文献   

14.
Maize ChitA chitinase is composed of a small, hevein‐like domain attached to a carboxy‐terminal chitinase domain. During fungal ear rot, the hevein‐like domain is cleaved by secreted fungal proteases to produce truncated forms of ChitA. Here, we report a structural and biochemical characterization of truncated ChitA (ChitA ΔN), which lacks the hevein‐like domain. ChitA ΔN and a mutant form (ChitA ΔN‐EQ) were expressed and purified; enzyme assays showed that ChitA ΔN activity was comparable to the full‐length enzyme. Mutation of Glu62 to Gln (ChitA ΔN‐EQ) abolished chitinase activity without disrupting substrate binding, demonstrating that Glu62 is directly involved in catalysis. A crystal structure of ChitA ΔN‐EQ provided strong support for key roles for Glu62, Arg177, and Glu165 in hydrolysis, and for Ser103 and Tyr106 in substrate binding. These findings demonstrate that the hevein‐like domain is not needed for enzyme activity. Moreover, comparison of the crystal structure of this plant class IV chitinase with structures from larger class I and II enzymes suggest that class IV chitinases have evolved to accommodate shorter substrates.  相似文献   

15.
Botulinum neurotoxins (BoNTs) are the most toxic proteins in nature. Rapid and sensitive detection of BoNTs is achieved by the endopeptidase–mass spectrometry (Endopep–MS) assay. In this assay, BoNT cleaves a specific peptide substrate and the cleaved products are analyzed by MS. Here we describe the design of a new peptide substrate for improved detection of BoNT type B (BoNT/B) in the Endopep–MS assay. Our strategy was based on reported BoNT/B–substrate interactions integrated with analysis method efficiency considerations. Incorporation of the new peptide led to a 5-fold increased sensitivity of the assay both in buffer and in a clinically relevant human spiked serum.  相似文献   

16.
Rapid and efficient structural analysis is key to the development of new monoclonal antibodies. We have developed a fast and easy process to obtain mass spectrometry profiles of antibodies from culture supernatant. Treatment of the supernatant with IdeS generates three fragments of 25 kDa that can be analyzed by liquid chromatography–mass spectrometry time-of-flight (LC–MS TOF) in one run: LC, Fd, and Fc/2. This process gives rapid access to isoform and glycoform profiles. To specifically measure the fucosylation yield, we included a one-pot treatment with EndoS that removes the distal glycan heterogeneity. Our process was successfully compared with high-performance capillary electrophoresis with laser-induced fluorescence detection (HPCE–LIF), currently considered as the “gold standard” method.  相似文献   

17.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS) has been used to discriminate moniliaceous fungal species; however, darkly pigmented fungi yield poor fingerprint mass spectra that contain few peaks of low relative abundance. In this study, the effect of dark fungal pigments on the observed MALDI mass spectra was investigated. Peptide and protein samples containing varying concentrations of synthetic melanin or fungal pigments extracted from Aspergillus niger were analyzed by MALDI–TOF and MALDI–qTOF (quadrupole TOF) MS. Signal suppression was observed in samples containing greater than 250 ng/μl pigment. Microscopic examination of the MALDI sample deposit was usually heterogeneous, with regions of high pigment concentration appearing as black. Acquisition of MALDI mass spectra from these darkly pigmented regions of the sample deposit yielded poor or no [M+H]+ ion signal. In contrast, nonpigmented regions within the sample deposit and hyphal negative control extracts of A. niger were not inhibited. This study demonstrated that dark fungal pigments inhibited the desorption/ionization process during MALDI–MS; however, these fungi may be successfully analyzed by MALDI–TOF MS when culture methods that suppress pigment expression are used. The addition of tricyclazole to the fungal growth media blocks fungal melanin synthesis and results in less melanized fungi that may be analyzed by MALDI–TOF MS.  相似文献   

18.
A novel magnetic bead-based protein kinase assay was developed using MALDI-TOF mass spectrometry (MALDI-TOF MS) and immunochemifluorescence as two independent detection techniques. Abltide substrate was immobilized onto magnetic beads via noncovalent biotin–streptavidin interactions. This noncovalent immobilization strategy facilitated peptide release and allowed MALDI-TOF MS analysis of substrate phosphorylation. The use of magnetic beads provided rapid sample handling and allowed secondary analysis by immunochemifluorescence to determine the degree of substrate phosphorylation. This dual detection technique was used to evaluate the inhibition of c-Abl kinase by imatinib and dasatinib. For each inhibitor, IC50 (half-maximal inhibitory concentration) values determined by these two different detection methods were consistent and close to values reported in the literature. The high-throughput potential of this new approach to kinase assays was preliminarily demonstrated by screening a chemical library consisting of 31 compounds against c-Abl kinase using a 96-well plate. In this proof-of-principle experiment, both MALDI-TOF MS and immunochemifluorescence were able to compare inhibitor potencies with consistent values. Dual detection may significantly enhance the reliability of chemical library screening and identify false positives and negatives. Formatted for 96-well plates and with high-throughput potential, this dual detection kinase assay may provide a rapid, reliable, and inexpensive route to the discovery of small-molecule drug leads.  相似文献   

19.
Inductively coupled plasma–mass spectrometry (ICP–MS)-based assays lend themselves to multiplexing due to the high resolution between mass channels, the sensitivity, and the reliability of the technique. Here the potential of ICP–MS-based protease assays is demonstrated with a quadruplex assay of cysteine proteases and metalloproteases. Four orthogonal peptide substrates were synthesized for the proteases calpain-1, caspase-3, matrix metalloprotease-9 (MMP-9), and a disintegrin and metalloprotease-10 (ADAM10). Each substrate carries a biotin tag at the C terminus and a diethylenetriaminepentaacetic acid (DTPA)-based lanthanide complex at the N terminus. The results demonstrate that this is a simple and reproducible analysis technique with excellent correlation between the single and multiplex assay formats.  相似文献   

20.
Botulinum neurotoxins (BoNTs) produced by Clostridium botulinum are the most poisonous substances known to humankind. It is essential to have a simple, quick, and sensitive method for the detection and quantification of botulinum toxin in various media, including complex biological matrices. Our laboratory has developed a mass spectrometry-based Endopep–MS assay that is able to rapidly detect and differentiate all types of BoNTs by extracting the toxin with specific antibodies and detecting the unique cleavage products of peptide substrates. Botulinum neurotoxin type E (BoNT/E) is a member of a family of seven distinctive BoNT serotypes (A–G) and is the causative agent of botulism in both humans and animals. To improve the sensitivity of the Endopep–MS assay, we report here the development of novel peptide substrates for the detection of BoNT/E activity through systematic and comprehensive approaches. Our data demonstrate that several optimal peptides could accomplish 500-fold improvement in sensitivity compared with the current substrate for the detection of both not-trypsin-activated and trypsin-activated BoNT/E toxin complexes. A limit of detection of 0.1 mouse LD50/ml was achieved using the novel peptide substrate in the assay to detect not-trypsin-activated BoNT/E complex spiked in serum, stool, and food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号