首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We studied the feasibility of estimating walking speed using a shank-mounted inertial measurement unit. Our approach took advantage of the inverted pendulum-like behavior of the stance leg during walking to identify a new method for dividing up walking into individual stride cycles and estimating the initial conditions for the direct integration of the accelerometer and gyroscope signals. To test its accuracy, we compared speed estimates to known values during walking overground and on a treadmill. The speed estimation method worked well across treadmill speeds and slopes yielding a root mean square speed estimation error of only 7%. It also worked well during overground walking with a 4% error in the estimated travel distance. This accuracy is comparable to that achieved from foot-mounted sensors, providing an alternative in sensor positioning for walking speed estimation. Shank mounted sensors may be of great benefit for estimating speed in walking with abnormal foot motion and for the embedded control of knee-mounted devices such as prostheses and energy harvesters.  相似文献   

2.
This study was designed to demonstrate that an accurate and reliable technique for measuring the rotational motion between rigid bodies can be developed from a video-based data collection system. Tests on the accuracy of the rotational measurements demonstrated that for each of five trials, under three test conditions, mean errors of less than 0.4° and standard deviations of less than 0.2° were found for all three joint axes. The reliability of the technique for evaluating ankle-subtalar motion during stance was also demonstrated, and the technique was then applied to evaluate ankle-subtalar motion during the stance phase of gait. The rotational motion of the combined ankle-subtalar joint was characterized by complexity and inter-subject variability. Two simplified models previously used to describe ankle-subtalar motion were tested using the current data and were proven to be inadequate for describing ankle-subtalar motion during stance.  相似文献   

3.
Accurate knowledge of the dynamic knee motion in-vivo is instrumental for understanding normal and pathological function of the knee joint. However, interpreting motion of the knee joint during gait in other than the sagittal plane remains controversial. In this study, we utilized the dual fluoroscopic imaging technique to investigate the six-degree-of-freedom kinematics and condylar motion of the knee during the stance phase of treadmill gait in eight healthy volunteers at a speed of 0.67 m/s. We hypothesized that the 6DOF knee kinematics measured during gait will be different from those reported for non-weightbearing activities, especially with regards to the phenomenon of femoral rollback. In addition, we hypothesized that motion of the medial femoral condyle in the transverse plane is greater than that of the lateral femoral condyle during the stance phase of treadmill gait. The rotational motion and the anterior–posterior translation of the femur with respect to the tibia showed a clear relationship with the flexion–extension path of the knee during the stance phase. Additionally, we observed that the phenomenon of femoral rollback was reversed, with the femur noted to move posteriorly with extension and anteriorly with flexion. Furthermore, we noted that motion of the medial femoral condyle in the transverse plane was greater than that of the lateral femoral condyle during the stance phase of gait (17.4±2.0 mm vs. 7.4±6.1 mm, respectively; p<0.01). The trend was opposite to what has been observed during non-weightbearing flexion or single-leg lunge in previous studies. These data provide baseline knowledge for the understanding of normal physiology and for the analysis of pathological function of the knee joint during walking. These findings further demonstrate that knee kinematics is activity-dependent and motion patterns of one activity (non-weightbearing flexion or lunge) cannot be generalized to interpret a different one (gait).  相似文献   

4.
Treadmill has been broadly used in laboratory and rehabilitation settings for the purpose of facilitating human locomotion analysis and gait training. The objective of this study was to determine whether dynamic gait stability differs or resembles between the two walking conditions (overground vs. treadmill) among young adults. Fifty-four healthy young adults (age: 23.9 ± 4.7 years) participated in this study. Each participant completed five trials of overground walking followed by five trials of treadmill walking at a self-selected speed while their full body kinematics were gathered by a motion capture system. The spatiotemporal gait parameters and dynamic gait stability were compared between the two walking conditions. The results revealed that participants adopted a “cautious gait” on the treadmill compared with over ground in response to the possible inherent challenges to balance imposed by treadmill walking. The cautious gait, which was achieved by walking slower with a shorter step length, less backward leaning trunk, shortened single stance phase, prolonged double stance phase, and more flatfoot landing, ensures the comparable dynamic stability between the two walking conditions. This study could provide insightful information about dynamic gait stability control during treadmill ambulation in young adults.  相似文献   

5.
The modulation of walking speed results in adaptations to the lower limbs which can be quantified using mechanical work. A 6 degree-of-freedom (DOF) power analysis, which includes additional translations as compared to the 3 DOF (all rotational) approach, is a comprehensive approach for quantifying lower limb work during gait. The purpose of this study was to quantify the speed-related 6 DOF joint and distal foot work adaptations of all the lower extremity limb constituents (hip, knee, ankle, and distal foot) in healthy individuals. Relative constituent 6 DOF work, the amount of constituent work relative to absolute limb work, was calculated during the stance and swing phases of gait. Eight unimpaired adults walked on an instrumented split-belt treadmill at slow, moderate, and typical walking speeds (0.4, 0.6, and 0.8 statures/s, respectively). Using motion capture and force data, 6 DOF powers were calculated for each constituent. Contrary to previously published results, 6 DOF positive relative ankle work and negative relative distal foot work increased significantly with increased speed during stance phase (p < 0.05). Similar to previous rotational DOF results in the sagittal plane, negative relative ankle work decreased significantly with increased speed during stance phase (p < 0.05). Scientifically, these findings provide new insight into how healthy individuals adapt to increased walking speed and suggest limitations of the rotational DOF approach for quantifying limb work. Clinically, the data presented here for unimpaired limbs can be used to compare with speed-matched data from limbs with impairments.  相似文献   

6.
Participation in running events has increased recently, with a concomitant increase in the rate of running related injuries (RRI). Mechanical overload is thought to be a primary cause of RRI, it is often detected using motion analysis to examine running mechanics during either overground or treadmill running. In treadmill running, no clear consensus for the number of strides required to establish stable kinematic data exists. The aim of this study was to establish the number of strides needed for stable data when analysing gait kinematics in the stance phase of treadmill running. Twenty healthy, masters age group, club runners completed a high intensity interval training run (HIIT) and an energy-expenditure matched medium intensity continuous run (MICR). Thirty consecutive strides at start and end of each run were identified. Sequential averaging was employed to determine the number of strides required to establish a stable value. No significant differences existed in the number of strides required to achieve stable values. Twenty consecutive strides are required to be 95% confident stable values exist for maximum angle, angle at initial foot contact, and range of motion at the ankle, knee, and hip joints variables at the ankle, knee, and hip joints, in all three planes of motion, and spatiotemporal regardless of running speed and time of capture.  相似文献   

7.
Activities of daily living (ADLs) generate complex, multidirectional forces in the anterior cruciate ligament (ACL). While calibration problems preclude direct measurement in patients, ACL forces can conceivably be measured in animals after technical challenges are overcome. For example, motion and force sensors can be implanted in the animal but investigators must determine the extent to which these sensors and surgery affect normal gait. Our objectives in this study were to determine (1) if surgically implanting knee motion sensors and an ACL force sensor significantly alter normal ovine gait and (2) how increasing gait speed and grade on a treadmill affect ovine gait before and after surgery. Ten skeletally mature, female sheep were used to test four hypotheses: (1) surgical implantation of sensors would significantly decrease average and peak vertical ground reaction forces (VGRFs) in the operated limb, (2) surgical implantation would significantly decrease single limb stance duration for the operated limb, (3) increasing treadmill speed would increase VGRFs pre- and post operatively, and (4) increasing treadmill grade would increase the hind limb VGRFs pre- and post operatively. An instrumented treadmill with two force plates was used to record fore and hind limb VGRFs during four combinations of two speeds (1.0 m/s and 1.3 m/s) and two grades (0 deg and 6 deg). Sensor implantation decreased average and peak VGRFs less than 10% and 20%, respectively, across all combinations of speed and grade. Sensor implantation significantly decreased the single limb stance duration in the operated hind limb during inclined walking at 1.3 m/s but had no effect on single limb stance duration in the operated limb during other activities. Increasing treadmill speed increased hind limb peak (but not average) VGRFs before surgery and peak VGRF only in the unoperated hind limb during level walking after surgery. Increasing treadmill grade (at 1 m/s) significantly increased hind limb average and peak VGRFs before surgery but increasing treadmill grade post op did not significantly affect any response measure. Since VGRF values exceeded 80% of presurgery levels, we conclude that animal gait post op is near normal. Thus, we can assume normal gait when conducting experiments following sensor implantation. Ultimately, we seek to measure ACL forces for ADLs to provide design criteria and evaluation benchmarks for traditional and tissue engineered ACL repairs and reconstructions.  相似文献   

8.
To study the mechanical output of skeletal muscle, four adult cats were trained to run on a treadmill and then implanted under sterile conditions and anesthesia with a force transducer on the soleus tendon and EMG electrodes in the muscle belly. After a two-week recovery period, five consecutive step cycles were filmed at treadmill speeds of 0.8, 1.3 and 2.2 m s-1. Locomotion data in vivo included individual muscle force, length and velocity changes and EMG during each step cycle. Data for an average step cycle at each speed were compared to the force-velocity properties obtained on the same muscle under maximal nerve stimulation and isotonic loading conditions in situ. Results indicate that the force and power generated at a given velocity of shortening during late stance in vivo were greater at the higher speeds of locomotion than the force and power generated at the same shortening velocity in situ. Strain energy stored in the muscle-tendon unit during the yield phase in early stance is felt to be a major contributor to the muscle's enhanced mechanical output during muscle shortening in late stance.  相似文献   

9.
The gait of a juvenile rhesus monkey as he walked, ran, underwent a run-gallop transition, and galloped on a motor-driven treadmill is described. Additionally, gait data for an adult animal during walking are also presented. Footfall sequences, stride durations, and absolute and relative swing and stance durations for all four limbs are reported, and, where possible, correlated with speed. Furthermore, support patterns and delays between footfalls are presented as a function of speed. The analysis revealed many similarities with previous studies on both primates and other species, but additionally demonstrated that the fore- and hindlimbs may not relate to speed in an identical manner and that galloping is initiated asymmetrically by a single diagonal couplet. The implications of these results in terms of understanding the neural mechanisms by which quadrupeds increase speed are discussed.  相似文献   

10.
The knowledge of articular cartilage contact biomechanics in the knee joint is important for understanding the joint function and cartilage pathology. However, the in vivo tibiofemoral articular cartilage contact biomechanics during gait remains unknown. The objective of this study was to determine the in vivo tibiofemoral cartilage contact biomechanics during the stance phase of treadmill gait. Eight healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system during gait on a treadmill. The tibia, femur and associated cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation during the stance phase of gait. Throughout the stance phase of gait, the magnitude of peak compartmental contact deformation ranged between 7% and 23% of the resting cartilage thickness and occurred at regions with thicker cartilage. Its excursions in the anteroposterior direction were greater in the medial tibiofemoral compartment as compared to those in the lateral compartment. The contact areas throughout the stance phase were greater in the medial compartment than in the lateral compartment. The information on in vivo tibiofemoral cartilage contact biomechanics during gait could be used to provide physiological boundaries for in vitro testing of cartilage. Also, the data on location and magnitude of deformation among non-diseased knees during gait could identify where loading and later injury might occur in diseased knees.  相似文献   

11.
Modulation of limb dynamics in the swing phase of locomotion   总被引:6,自引:0,他引:6  
A method was presented for quantifying cat (Felis catus) hind limb dynamics during swing phase of locomotion using a two-link rigid body model of leg and paw, which highlighted the dynamic interactions between segments. Comprehensive determination was made of cat segment parameters necessary for dynamic analysis, and regression equations were formulated to predict the inertial parameters of any comparable cat. Modulations in muscle and non-muscle components of knee and ankle joint moments were examined at two treadmill speeds using three gaits: (a) pace-like walk and trot-like walk, at 1.0 ms-1, and (b) gallop, at 2.1 ms-1. Results showed that muscle and segment interactive moments significantly effected limb trajectories during swing. Some moment components were greater in galloping than in walking, but net joint maxima were not significantly different between speeds. Moment magnitudes typically were greater for pace-like walking than for trot-like walking at the same speed. Generally, across gaits, the net and muscle moments were in phase with the direction of distal joint motion, and these same moments were out of phase with proximal joint motion. Intersegmental dynamics were not modulated exclusively by speed of locomotion, but interactive moments were also influenced significantly by gait mode.  相似文献   

12.
Gait speed is an essential parameter of gait analysis. Our study proposed a simple and accurate method to extract a mean gait speed during walking on a treadmill using only kinematic data from markers placed on the heels of the participants’ feet. This method provided an attractive, simple method that remains resistant to errors in treadmill calibration. In addition, this method required only two markers, since heel markers are essential to gait analysis, and the proposed method is robust enough to differentiate among various gait speeds (mean error <1%).  相似文献   

13.
Gait acts as a gate for reflexes from the foot   总被引:1,自引:0,他引:1  
During human gait, electrical stimulation of the foot elicits facilitatory P2 (medium latency) responses in TA (tibialis anterior) at the onset of the swing phase, while the same stimuli cause suppressive responses at the end of swing phase, along with facilitatory responses in antagonists. This phenomenon is called phase-dependent reflex reversal. The suppressive responses can be evoked from a variety of skin sites in the leg and from stimulation of some muscles such as rectus femoris (RF). This paper reviews the data on reflex reversal and adds new data on this topic, using a split-belt paradigm. So far, the reflex reversal in TA could only be studied for the onset and end phases of the step cycle, simply because suppression can only be demonstrated when there is background activity. Normally there are only 2 TA bursts in the step cycle, whereas TA is normally silent during most of the stance phase. To know what happens in the stance phase, one needs to have a means to evoke some background activity during the stance phase. For this purpose, new experiments were carried out in which subjects were asked to walk on a treadmill with a split-belt. When the subject was walking with unequal leg speeds, the walking pattern was adapted to a gait pattern resembling limping. The TA then remained active throughout most of the stance phase of the slow-moving leg, which was used as the primary support. This activity was a result of coactivation of agonistic and antagonistic leg muscles in the supporting leg, and represented one of the ways to stabilize the body. Electrical stimulation was given to a cutaneous nerve (sural) at the ankle at twice the perception threshold. Nine of the 12 subjects showed increased TA activity during stance phase while walking on split-belts, and 5 of them showed pronounced suppressions during the first part of stance when stimuli were given on the slow side. It was concluded that a TA suppressive pathway remains open throughout most of the stance phase in the majority of subjects. The suggestion was made that the TA suppression increases loading of the ankle plantar flexors during the loading phase of stance.  相似文献   

14.
The metabolic cost of leg swing in running is highly controversial. We investigated the cost of initiating and propagating leg swing at a moderate running speed and some of the muscular actions involved. We constructed an external swing assist (ESA) device that applied small anterior pulling forces to each foot during the first part of the swing phase. Subjects ran on a treadmill at 3.0 m/s normally and with ESA forces up to 4% body weight. With the greatest ESA force, net metabolic rate was 20.5% less than during normal running. Thus we infer that the metabolic cost of initiating and propagating leg swing comprises approximately 20% of the net cost of normal running. Even with the greatest ESA, mean electromyograph (mEMG) of the medial gastrocnemius and soleus muscles during later portions of stance phase did not change significantly compared with normal running, indicating that these muscles are not responsible for the initiation of leg swing. However, with ESA, rectus femoris mEMG during the early portions of swing phase was as much as 74% less than during normal running, confirming that it is responsible for the propagation of leg swing.  相似文献   

15.
This study evaluated the performance of a walking speed estimation system based on using an inertial measurement unit (IMU), a combination of accelerometers and gyroscopes. The walking speed estimation algorithm segments the walking sequence into individual stride cycles (two steps) based on the inverted pendulum-like behaviour of the stance leg during walking and it integrates the angular velocity and linear accelerations of the shank to determine the displacement of each stride. The evaluation was performed in both treadmill and overground walking experiments with various constraints on walking speed, step length and step frequency to provide a relatively comprehensive assessment of the system. Promising results were obtained in providing accurate and consistent walking speed/step length estimation in different walking conditions. An overall percentage root mean squared error (%RMSE) of 4.2 and 4.0% was achieved in treadmill and overground walking experiments, respectively. With an increasing interest in understanding human walking biomechanics, the IMU-based ambulatory system could provide a useful walking speed/step length measurement/control tool for constrained walking studies.  相似文献   

16.
Changes in knee function associated with treadmill ambulation   总被引:2,自引:2,他引:0  
A comparison of level walking, on a walkway and on a treadmill, was performed using ten normal subjects. Motion about the knee was measured using a triaxial electrogoniometer, and foot-floor contact patterns were recorded by means of four foot switches attached to the sole of each shoe. On the walkway, the data were collected with the subject moving at a comfortable walking speed. The treadmill was then set at the average velocity obtained on the walkway. Knee joint rotation in the coronal and transverse planes did not change significantly between the walkway and the treadmill. In the sagittal plane, significant differences were found for total motion (p less than 0.01), swing phase motion (p less than 0.01), knee position at heel strike (p less than 0.05), and maximum swing phase extension (p less than 0.01). A comparison of the foot-floor contact patterns between walkway and treadmill ambulation revealed reduced heel contact time, with an increase in toe contact while on the treadmill. It was concluded that sagittal plane knee kinematics during level treadmill walking differ significantly from level overground walking.  相似文献   

17.
This study evaluated the performance of a walking speed estimation system based on using an inertial measurement unit (IMU), a combination of accelerometers and gyroscopes. The walking speed estimation algorithm segments the walking sequence into individual stride cycles (two steps) based on the inverted pendulum-like behaviour of the stance leg during walking and it integrates the angular velocity and linear accelerations of the shank to determine the displacement of each stride. The evaluation was performed in both treadmill and overground walking experiments with various constraints on walking speed, step length and step frequency to provide a relatively comprehensive assessment of the system. Promising results were obtained in providing accurate and consistent walking speed/step length estimation in different walking conditions. An overall percentage root mean squared error (%RMSE) of 4.2 and 4.0% was achieved in treadmill and overground walking experiments, respectively. With an increasing interest in understanding human walking biomechanics, the IMU-based ambulatory system could provide a useful walking speed/step length measurement/control tool for constrained walking studies.  相似文献   

18.
Hip joint forces in sheep.   总被引:3,自引:0,他引:3  
Testing orthopaedic implants at the proximal femur of sheep requires knowledge of the contact forces acting on this joint. Telemeterized implants were used for long-term measurements of these forces in four sheep, mostly during treadmill walking. Joint forces in the same sheep varied widely from day to day and interindividual differences were also pronounced. Forces during walking were mostly higher than in previous short-term measurements. At medium walking speed, loads in the range of 65-140% of the body weight were typical. Fast walking increased the forces by only 20%, compared to slow speed. Stomping on the ground at the beginning of the stance phase and starting to run freely led to very high forces. The highest values observed were nearly four times the body weight. As in humans, the directions of high forces varied only slightly in the frontal plane throughout the whole stance phase but much more in the transverse plane. With regard to the force magnitudes and their directions, sheep seem to be a good model for testing human implant at the proximal femur.  相似文献   

19.
The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the propagation delay of sound when transmitted in air, this system is able to record the position of the subjects' feet. A small ultrasonic receiver is attached to both shoes of the subject while a transmitter is placed stationary on the floor. Four healthy subjects were used to test the device. Subtracting positions of the foot with zero velocity yielded step and stride length. The duration of stance and swing phase was calculated from heel-strike and toe-off. Comparison with data obtained from foot contact switches showed that applying two relative thresholds to the speed graph of the foot could reliably generate heel-strike and toe-off. Although the device is tested on healthy subjects in this study, it promises to be extremely valuable in examining pathological gait. When gait is asymmetrical, walking speed is not constant or when patients do not completely lift their feet, most existing devices will fail to correctly assess the proper gait parameters. Our device does not have this shortcoming and it will accurately demonstrate asymmetries and variations in the patient's gait. As an example, the recording of a left hemiplegic patient is presented in the discussion.  相似文献   

20.
Three-dimensional electrogoniometric gait recording   总被引:1,自引:0,他引:1  
Gait recordings of twenty healthy subjects were made on a treadmill and on level ground by means of a light-weight computerised electrogoniometer. The angular excursions in three planes were recorded simultaneously with regard to hip, knee and ankle joints in both legs. Determinations of the mean values and dispersions were then made. In order to establish the reliability of the method tests and retests were performed. Also its validity was checked by comparing the goniometric recordings with concomitant measurements obtained by other methods. The reliability and validity of the method was found to be satisfactory. Apart from flexion of the hip and knee joints during stance phase (i.e. a difference of 2 and 2.4 degrees respectively), no difference was ascertained between walking on a treadmill and walking on level ground.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏