首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Valproyl taurinamides are a novel group of compounds that possess anticonvulsant activity. In this study a gas chromatographic micromethod was developed for the quantification of selected valproyl taurinamides and some of their metabolites in biological samples. Valproyl taurinamide (VTD), N-methyl valproyl taurinamide (M-VTD), N,N-dimethyl valproyl taurinamide (DM-VTD) and N-isopropyl valproyl taurinamide (I-VTD) were analyzed in mouse and dog plasma and in dog urine using gas chromatography. Flame ionization detection and mass spectrometric detection were compared. The plasma samples were prepared by solid-phase extraction using C(18) cartridges. The urine samples were prepared by liquid-liquid extraction. The sample volume used was 100 microl of dog plasma, 50 microl of mouse plasma and 20 microl of dog or mouse urine. The quantification range of the method was 1.5-50 mg/l in dog plasma (VTD only), 2.5-250 mg/l in mouse plasma (0.7-90 pmol injected) and 0.04-2 mg/ml in dog urine (VTD only). The inter-day precision in plasma and urine samples was around 10% for all quantified concentrations except LOQ (15-20%). The accuracy for all four compounds was between 90 and 110% within the entire concentration range. The developed method was suitable for quantification of a series of CNS-active valproyl taurineamide derivatives in biological samples at relevant in vivo concentrations.  相似文献   

2.
3.
4.
An enantioselective high-performance liquid chromatographic method for the determination of E3810, a new anti-ulcer agent, in Beagle dog plasma and rat plasma has been developed. After extraction from plasma with ethyl acetate. E3810 enantiomer were measured by reversed-phase high-performance liquid chromatography on a Chiralcel OD-R column. The enantiomers were detected by ultraviolet absorbance detection at 290 nm. The recoveries of E3810 enantiomers and internal standard were greater than 91%. The calibration curves were linear from 0.03 to 20 μg/ml for Beagle dog plasma and from 0.1 to 100 μg/ml for rat plasma. The limits of quantification of both enantiomers were 0.03 μg/ml for Beagle dog plasma and 0.1 μg/ml for rat plasma. The intra- and inter-day accuracy and precision data showed good reproducibility of the method. The assay was applied for the analysis of E3810 enantiomers in plasma after intravenous administration of racemic E3810 to Beagle dogs and rats. This method should be very useful for enantioselective pharmacokinetic studies of E3810.  相似文献   

5.
Steroids are primarily present in human fluids in their sulfated forms. Profiling of these compounds is important from both diagnostic and physiological points of view. Here, we present a novel method for the quantification of 11 intact steroid sulfates in human serum by LC-MS/MS. The compounds analyzed in our method, some of which are quantified for the first time in blood, include cholesterol sulfate, pregnenolone sulfate, 17-hydroxy-pregnenolone sulfate, 16-α-hydroxy-dehydroepiandrosterone sulfate, dehydroepiandrosterone sulfate, androstenediol sulfate, androsterone sulfate, epiandrosterone sulfate, testosterone sulfate, epitestosterone sulfate, and dihydrotestosterone sulfate. The assay was conceived to quantify sulfated steroids in a broad range of concentrations, requiring only 300 μl of serum. The method has been validated and its performance was studied at three quality controls, selected for each compound according to its physiological concentration. The assay showed good linearity (R2 > 0.99) and recovery for all the compounds, with limits of quantification ranging between 1 and 80 ng/ml. Averaged intra-day and between-day precisions (coefficient of variation) and accuracies (relative errors) were below 10%. The method has been successfully applied to study the sulfated steroidome in diseases such as steroid sulfatase deficiency, proving its diagnostic value. This is, to our best knowledge, the most comprehensive method available for the quantification of sulfated steroids in human blood.  相似文献   

6.
A sensitive high-performance liquid chromatographic method with fluorescence detection has been developed for determination of MCC-555 (5-[[6-(2-fluorbenzyl)-oxy-2-naphy] methyl]-2,4-thiazolidinedione) in beagle dog plasma. Sample preparation was done by protein precipitation with acetonitrile and a synthetic intermediate of MCC-555 (5-[[6-(2-fluorbenzyl)-oxy-2-naphy] methylene]-2,4-thiazolidinedione) was used as the internal standard (IS). The isocratic mobile phase consisted of acetonitrile-10 mmol/l sodium phosphate buffer (pH 4.5) (65:35, v/v) was delivered at a flow rate of 1 ml/min to a Kromasil C(18) reversed-phase column (250 mm x 4.6 mm, 5 microm). The compounds were detected by fluorescence detection, using an excitation wavelength of 232 nm, and emission wavelength of 352 nm. Calibration curves of MCC-555 were linear in the concentration range of 0.005-2.0 microg/ml. Intra- and inter-day precision ranged from 3.4 to 5.4% and 3.0 to 8.8%, respectively. No endogenous interferences were observed with either MCC-555 or IS. The assay is simple, economical, precise, and is directly applicable to pharmacokinetic studies in beagle dogs involving three dose administrations.  相似文献   

7.
An HPLC assay for plasma analysis of LY303366 (I), a semi-synthetic lipopeptide antifungal related to echinocandin B (ECB), was developed to support the selection and subsequent preclinical development of I. The method involved extraction of I from plasma with the aid of solid-phase extraction (SPE) cartidges followed by reversed-phase HPLC with UV detection at 300 nm. The method is simple, selective and is applicable to dog, rat, mouse and rabbit plasma. Validation studies using dog plasma showed that the values obtained for parameters of linearity, precision and accuracy were within acceptable limits. Based on analysis of 0.3 ml of plasma, the lower limit of quantitation was 20 ng/ml. The method has been successfully applied to determine the pharmacokinetic parameters of I in the dog following intravenous (i.v.) and oral administration. Compared to first generation ECB antifungal agents, the results of the i.v. dog study indicated a 50% reduction in clearance of the drug from plasma (0.1 l/h/kg) and an 18-fold increase in the volume of distribution at steady state (1.8 l/kg). When administered orally, compound I had an absolute bioavailability of 9%; however, plasma levels remained above the MIC for C. albicans (0.005 μg/ml) through 48 h. Given the excellent potency of I and its broad spectrum of activity relative to first generation ECB antifungal agents, the assay results for I indicate the potential for its use as a broad spectrum i.v. and oral antifungal agent.  相似文献   

8.
A high-performance liquid chromatographic method with ultraviolet detection has been developed to quantify NB-506 and its active metabolite in human plasma and urine. This method is based on solid-phase extraction, thereby allowing the simultaneous measurement of the drug and metabolite with the limit of quantification of 0.01 μg/ml in plasma and 0.1 μg/ml in urine. Standard curves for the compounds were linear in the concentration ranges investigated. The range for the drug in plasma was 0.01–2.5 μg/ml, and for the metabolite 0.01–1 μg/ml. In urine, the range for both compounds was 0.1–10 μg/ml. The method was validated and applied to the assay of plasma and urinary samples from phase I studies.  相似文献   

9.
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 μl of plasma) and 25 ng/ml (50 μl of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.  相似文献   

10.
A method for the determination of piracetam in human plasma and urine by liquid chromatography with absorbance detection at 206 nm and isocratic elution is proposed. The assay involved a liquid-liquid extraction into hexane-2-propanol at pH 9.2. The calibration graphs were linear in the range 3–40 mg/l in plasma and 100–2000 mg/l in urine. Bias was negligible and coefficients of variation were less than 10% throughout the working range except at 100 mg/l in urine. The limits of quantification were 3 mg/l in plasma and 100 mg/l in urine. The assay was reliably used for pharmacokinetic studies in humans after administration of 800 mg of piracetam per os.  相似文献   

11.
ADP-ribose pyrophosphatase (ADPRase) hydrolyzes ADP-ribose to ribose-5-phosphate and AMP. The ADPRase activity have been assessed by coupling the reaction to alkaline phosphatase and colorimetrically measuring the amount of inorganic phosphate released from AMP that is one of the products of ADPRase. Another but less sensitive colorimetric method has been employed: the reaction mixture was treated with charcoal to adsorb the adenine-containing compounds such as AMP and ADPR and subsequently remaining ribose-5-phosphate was measured colorimetrically. However, the measurement of inorganic phosphate cannot be feasible to assay ADPRase in phosphate-containing samples and the determination of ribose-5-phosphate also is less sensitive. Here we develop a fluorescent assay for ADPRase that utilizes 1, N(6)-etheno ADP-ribose, a fluorescent analogue of ADP-ribose. This method measures fluorescent 1, N(6)-etheno adenosine that is produced by coupling the hydrolysis of 1, N(6)-etheno ADP-ribose to dephosphorylation with alkaline phosphatase. The fluorometric assay is comparable in sensitivity and useful for ADPRase assay in phosphate-containing samples.  相似文献   

12.
Current methods of quantitation of histamine and its major metabolite N tau-methylhistamine are inaccurate and insensitive to the very low concentrations that exist in plasma samples. Therefore, an accurate and sensitive method for quantification in plasma has been developed using the stable isotope dilution assay with negative ion-chemical ionization mass spectrometry. For histamine, after the addition of [2H4]histamine to 2 ml of plasma, the plasma sample is deproteinized, extracted into butanol, back extracted into HCl, derivatized to the pentafluorobenzyl derivative (CH2C6F5)3-histamine, purified on silica gel columns, and then quantified with negative ion-chemical ionization mass spectrometry by selected ion monitoring of the ratio of ions m/z 430/434. For N tau-methylhistamine, after the addition of N tau-[2H3]methylhistamine to 2 ml of plasma, the plasma sample is deproteinized, extracted into butanol, back extracted into HCl, derivatized to the heptafluorobutyryl derivative (C3F7CO2)2-N tau-methylhistamine, purified on silica gel columns, and then quantified with negative ion-chemical ionization mass spectrometry by selected ion monitoring of the ratio of ions m/z 497/500. The precision of the histamine assay is 3.1% and the accuracy is 95.5 +/- 2.5% while the precision of the N tau-methylhistamine assay is 1.9% and the accuracy is 106.8 +/- 1.9%. The lower limits of sensitivity are 1 pg for histamine and 6 pg for N tau-methylhistamine injected on column. Using the assay in three normal human volunteers, plasma concentrations of histamine were 130, 92, and 85 pg/ml, and of N tau-methylhistamine were 229, 228, and 216 pg/ml. This assay provides a very sensitive and accurate method of quantitation of histamine and N tau-methylhistamine in plasma samples.  相似文献   

13.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of L-365,260 (I), a cholecystokinin and gastrin receptor antagonist, in dog and rat plasma. The method involves liquid—liquid extraction and HPLC with ultraviolet detection. Standard curves were linear over the range 7.5–2000 ng/ml for rat and dog plasma. The method is reproducible and reliable with a detection limit of 7.5 ng/ml in biological fluids. The mean coefficients of variation for concentrations within the range of the standard curve range were 3.84 and 2.56%, respectively, for intra-day analysis and 4.48 and 4.26%, respectively, for inter-day analysis. Application of the development was successfully demonstrated by quantifying the concentration of I in both dog and rat plasma samples following an intravenous or oral dose of 5 mg/kg I.  相似文献   

14.
A gradient reversed-phase HPLC assay has been developed to determine sodium ferulate (SF) in beagle dog plasma with tinidazole as an internal standard. Chromatographic separation was made on a C(18) column using 0.5% acetic acid and acetonitrile (80:20, v/v) as mobile phase. UV detection was performed at 320 nm. The calibration curve for SF was linear in the range of 0.05-10 microg/ml, and the achieved limit of quantification (LOQ) was 51.4 ng/ml. The results of linearity, within- and between-day precision, and accuracy demonstrate that this method is reliable, sensitive and sufficient for in vivo beagle dog pharmacokinetic (PK) studies of SF.  相似文献   

15.
Radioimmunoassay techniques for the measurement of gastrointestinal hormones have been modified to allow simultaneous assay of both secretin and gastrin in the same plasma samples. The system employs antibodies with high specificity for these two hormones and both 125I-labeled secretin and 131I-labeled gastrin as markers. Separation of the free from the bound form of the hormones was achieved by plasma- and dextran-coated charcoal. The unique separation method has been found to be independent of the uniformity of plasma samples. The sensitivity and the reliability of the simultaneous assays were comparable to those of the single assays. The fasting levels of human plasma secretin and gastrin obtained by the simultaneous assay were 62.9 ± 3.6 and 43.5 ± 2.8 pg/ml respectively.  相似文献   

16.
A selective and sensitive high-performance liquid chromatographic assay for a novel cognitive enhancer, X9121 (I), and its mono N-oxide metabolite, XG696 (II), in dog plasma has been developed. Compounds I, II and internal standard (I.S.) were first extracted from dog plasma using a solid-phase Bond Elut Certify I 10-ml LRC reservoir extraction cartridge. Chromatographic separation of I, II and I.S. was conducted on a reversed-phase Zorbax Stable Bond cyano column. Ammonium acetate buffer (0.05 M, pH 6)-acetonitrile-triethylamine (75:25:0.1, v/v) was used as the mobile phase. Detection of all three compounds was by UV light absorbance at 313 nm. Using 0.5 ml of dog plasma for extraction, the minimum quantifiable limit was 10 ng/ml and the assay was linear from 10 to 5400 ng/ml. The coefficients of variation for intra-day precision ranged from 2.2 to 8.5% for I and from 2.5 to 9.8% for II. The coefficients of variation for the inter-day precision for these two compounds ranged from 2.6 to 9.0% and from 3.6 to 16.2%, respectively. The absolute percent differences for the accuracy results were within 11.0% of the spiked concentrations. Compounds I and II were stable in frozen plasma at −20°C for at least 67 days.  相似文献   

17.
To facilitate clinical investigation of metabolic acidosis, a high-performance liquid chromatographic method was adapted and validated for the chiral separation of D-(-) and L-(+)-lactic acid in calf feces, rumen fluid and urine. A non-chiral method was also adapted and validated for the separation of pyruvic, acetic and DL-(+/-)-lactic acids in calf feces and DL-(+/-)-lactic and pyruvic acids in rumen fluid. Separation and quantification were achieved using a reversed phase sulphonated polystyrenedivinylbenzene analytical column for pyruvic, acetic and racemic lactic acids and by a 3 microm octadecylsilane (ODS) packed analytical column coated with N,N-dioctyl-L-alanine as the chiral selector for the separation of lactic acid enantiomers with Cu(II)-containing eluents by stereoselective ligand exchange chromatography. Endogenous analytes were present in validation samples over a range of concentrations (0.2-14.8 mmol/l). For the stereoselective assay, mean intra-day accuracy ranged from 90.6 to 108.4% and intra-day precision from 0.3 to 13.8%. For the non-stereoselective assay, mean intra-day accuracy ranged from 90.4 to 108.8% and intra-day precision from 1.5 to 11.1%. The limit of quantitation was 1.0 mmol/l for D- and L-lactic acid, 0.06125 mmol/l for pyruvic acid, 1.0 mmol/l for DL-lactic acid and 1 mmol/l for acetic acid. These assays can be used to study the role of the gastrointestinal tract and kidney in metabolic acidosis.  相似文献   

18.
Traditional clinical assays for nonprotein nitrogen compounds, such as creatine and creatinine, have focused on the use of enzymes or chemical reactions that allow measurement of each analyte separately. Most of these assays are mainly directed to urine quantification, so that their applicability on plasma samples is frequently hard to perform. This work describes a simple free zone capillary electrophoresis method for the simultaneous measurement of creatinine and creatine in human plasma. The effect of analytical parameters such as concentration and pH of Tris-phosphate running buffer and cartridge temperature on resolution, migration times, peak areas, and efficiency was investigated. Good separation was achieved using a 60.2-cm x 75-microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer, pH 2.25, at 15 degrees C, in less than 8 min. We compared the present method to a validated capillary electrophoresis assay, by measuring plasma creatinine in 120 normal subjects. The obtained data were compared by the Passing-Bablok regression and the Bland-Altman test. Moreover the performance of the developed method was assessed by measuring creatine and creatinine in 16 volunteers prior to and after a moderate physical exercise.  相似文献   

19.
A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (±)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C18 cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).  相似文献   

20.
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of chloroquine, an antimalarial drug, in plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method is based on simple protein precipitation with methanol followed by a rapid isocratic elution with 10 mM ammonium acetate buffer/methanol (25/75, v/v, pH 4.6) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 320.3-->247.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 2.0-489.1 ng/mL for chloroquine in dog plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) were 0.4 and 2.0 ng/mL, respectively in 0.05 mL plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range of 2.0-489.1 ng/mL. A run time of 2.0 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully used to analyze samples of dog plasma during non-clinical study of chloroquine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号