首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two methods which employ whole cells are described and compared for the detection of human IgG and IgM anti-brucella antibodies. Dot ELISA and ELISA were shown to be suitable for a screening diagnosis of human brucellosis. Titres of antibodies obtained by dot ELISA showed 100% coincidence for IgG and 97% for IgM, compared with agglutination and complement fixation tests; when ELISA was used 11 % positive sera were not detected. The comparison of these two methods with the conventional serological test kit indicated that both dot ELISA and ELISA were sensitive, reproducible and specific for the quantification of IgG and IgM anti-brucella antibodies.  相似文献   

2.
Two methods which employ whole cells are described and compared for the detection of human IgG and IgM anti-brucella antibodies. Dot ELISA and ELISA were shown to be suitable for a screening diagnosis of human brucellosis. Titres of antibodies obtained by dot ELISA showed 100% coincidence for IgG and 97% for IgM, compared with agglutination and complement fixation tests; when ELISA was used 11% positive sera were not detected. The comparison of these two methods with the conventional serological test kit indicated that both dot ELISA and ELISA were sensitive, reproducible and specific for the quantification of IgG and IgM antibrucella antibodies.  相似文献   

3.
Background: Diagnosis of acute and past infection with parvovirus B19 is based on detection of IgM and IgG antibodies.Objectives: To evaluate two commercial recombinant antigen-based enzyme immunoassay (EIA) test kits for detection of IgM and IgG antibodies to parvovirus B19 and to compare the commercial EIAs to in-house EIA test procedures.Study design: A panel of 121 sera was used to compare the three IgM EIAs. The panel included 84 sera submitted for parvovirus B19 testing and 37 sera that were IgM positive for other viral pathogens. The same serum panel plus an additional 14 sera submitted for B19 testing was used to compare the three IgG EIAs. The commercial EIAs were performed according to manufacturers' instructions. Using the in-house EIA test procedures as the reference, sensitivity and specificity for each of the commercial EIAs was determined.Results: The commercial B19 IgM EIAs showed agreements of 95.0 and 93.4% to the in-house IgM EIA. Compared to the in-house B19 IgM EIA, the commercial B19 IgM EIAs, were 97.4 and 97.5% sensitive, respectively. Specificities were 93.5 and 91.4%, respectively. Sensitivities for the commercial IgG EIAs, compared to in-house IgG EIA, were 88.0 and 85.2%, respectively, and specificities were 94.1 and 98.0%.Conclusion: We found that the commercial parvovirus B19 IgM and IgG EIAs are comparable to standard in-house EIAs and are suitable for testing for B19 antibodies in human sera.  相似文献   

4.
Cystic echinococcosis (CE) is the larval cystic stage (called echinococcal cysts) of a small taeniid-type tapeworm (Echinococcus granulosus). Carnivores such as dogs are usually definitive hosts. Intermediate hosts are typically herbivores such as sheep and cattle. CE can be detected using various imaging techniques such as ultrasonography or radiology. Moreover the primary diagnosis has to be confirmed by serological tests since the clinical signs of the disease are non-specific. This study examined the antigenic band patterns useful for serologic diagnosis of hydatidosis. We also report on the post-operative evolution of patients treated for this disease and also determined the diagnostic performance of Western blot IgG kit. Twenty-five (16 females and 9 males) non-operated patients with hydatid cysts (NOP) and 33 (21 females and 12 males) operated patients with hydatid cysts (OP) were included as study group and 22 healthy individuals (14 females and 8 males) with no known chronic diseases were included as a control group. The ages of the patients and control group individuals were between 16-83 years. Patient and control groups were matched for age and sex. Cyst hydatid IgG antibodies were detected in the sera from all patient groups but no antibodies were found in the sera from the control group using ELISA IgG method. Twenty-three (92%) non-operated patients and 18 (54.5%) operated patients exhibited positive results when Western blot IgG kit was used. The P7 band pattern was detected in the sera from all operated and non-operated patients. Twenty-seven of these positive cases had p7 and (p7+p16/18), (p7+p24/26) or (p7+p16/18+p24/26). No antibodies against p7, p16/18 ve p24/26 band patterns were seen in sera from the control group A statistically significant difference was detected between operated and nonoperated patients for Western blot positivity.(p<0.01). p: 0.018- X2=5,604- OR: 0.176- 95% CI: 0.037- 0.841. The sensitivity, specificity, positive prediction and negative prediction values of Echinococcus granulosus Western blot kit for 25 cases with CE and 22 healthy controls were calculated as 92%, 100%, 100% and 91.7%, respectively. In conclusion, we suggest that monitoring p7 in all non-operated patients may be useful to determine the efficiacy of medical treatment and that monitoring p7 antibodies using serological and Western blot methods in operated patients may be useful for the screening of post-operative evolution in patients with hydatid cyst.  相似文献   

5.
A seroepidemiologic study using the microimmunofluorescence (MIF) technique was conducted to determine the prevalence of Chlamydophila pneumoniae IgG antibodies among 205 healthy Singapore university undergraduates using the MRL Diagnostics MIF test kit. The overall seroprevalence was 35.1% with significantly higher seropositivity rates among males than females (48.2 vs. 18.7%, P < 0.001). A comparative study using the Labsystems MIF test kit was conducted on sera from 192 students. Using the MRL MIF test as the reference, the sensitivity and specificity of Labsystems MIF test were 92.6 and 87.9%, respectively. A total of 78 samples comprising 15 MIF-negative and 63 MIF-positive samples were also tested for complement-independent neutralizing antibodies in vitro. All the 78 samples and 11 additional MIF-negative samples were also tested for IgM, IgG and IgA against C. pneumoniae by enzyme immunoassay (EIA) using the Labsystems EIA test kit. None of these 89 samples were seropositive for IgM. The percentages of IgG and IgA seropositivity increased with increasing grades of MIF-positivity. Among the IgG seropositive samples, 69.1% were also positive for IgA, suggesting that a high proportion of infected individuals also had IgA antibodies denoting chronicity. Neutralizing antibodies were detected in 22.2% of MIF-positive sera, but only in 6.7% of MIF-negative sera. 26.4 and 34.2% of samples which were IgG and IgA seropositive respectively also exhibited neutralizing activity. The percentages of MIF-positive sera with neutralizing activity increased with the grade of MIF positivity, i.e. 0% (1+), 7.1% (2+), 18.8% (3+), and 63.6% (4+). High-grade MIF positivity (particularly with MRL MIF kits) may represent a useful serologic marker of predictive value for neutralizing activity.  相似文献   

6.
We developed a enzyme linked immunosorbent assay (ELISA) for measuring IgG subclasses concentration in serum. For this we used monoclonal antibodies. The specificity of these antibodies was evaluated with a panel of myeloma proteins belonging to the 4 IgG subclasses. The ELISA was sensitive (allowing the detection of subclasses at ng level) and accurate (inter-assay coefficient of variation of 14%). Using the WHO serum 67/97 as reference, we determined the concentration of IgG subclasses in a pool of sera. In addition concentrations were measured in 69 healthy adults to study the distribution of each IgG subclass. A good correlation (r = 0.78) was obtained between the sum of the subclasses measured by ELISA and total IgG measured by immunonephelometry.  相似文献   

7.
Antibody detection assays have long been the first line test to confirm infection with the zoonotic parasite Toxoplasma gondii. However, challenges exist with serological diagnosis, especially distinguishing between acute, latent and reactivation disease states. The sensitivity and specificity of serological tests might be improved by testing for antibodies against parasite antigens other than those typically found on the parasite surface during the acute stage. To this end, we analysed the reactivity profile of human sera, identified as positive for anti-Toxoplasma gondii IgG in traditional assays, by indirect immunofluorescence reactivity to acute stage intracellular tachyzoites and in vitro-induced latent stage bradyzoites. The majority of anti-Toxoplasma gondii IgG positive sera recognised both intracellularly replicating tachyzoites and in vitro-induced bradyzoites with varying patterns of immune-reactivity. Furthermore, anti-bradyzoite antibodies were not detected in sera that were IgM-positive/IgG-negative. These results demonstrate that anti-Toxoplasma gondii-positive sera may contain antibodies to a variety of antigens in addition to those traditionally used in serological tests, and suggest the need for further investigations into the utility of anti-bradyzoite-specific antibodies to aid in diagnosis of Toxoplasma gondii infection.  相似文献   

8.
The autoantibodies induced in (C57BL/6 x BALB/c)F1 mice during Trypanosoma cruzi (CL strain) infection were analyzed and compared with natural autoantibodies present in healthy mice. Mice were killed at intervals after infection and their sera were tested by enzyme immunoassay against a panel of self- and non-self-Ag: actin, myoglobin, myosin, tubulin, DNA, and TNP-OVA. The level of IgM and IgG autoantibodies against all Ag started to increase from day 15 until 6 wk after the parasite infection. The high level of all autoantibodies persisted 3 mo postinfection, and 1 yr later, half of the mice still had elevated levels of IgM and IgG autoantibodies, particularly antitubulin IgG antibodies. IgM and IgG were isolated from pools of normal and infected mouse sera and their binding capacity to all Ag was compared. The titers of infected mouse sera were increased and the slopes of both IgM and IgG binding curves of autoantibodies to actin, myosin, and tubulin were greater than those of control mouse sera, indicating higher affinities. The average dissociation constant of the IgG2a autoantibody to mouse tubulin was 5 times lower than that of natural antitubulin IgG2a antibodies. Furthermore, absorption of the IgG from infected mouse sera onto a tubulin immunoadsorbent removed half the reactivity with tubulin and also with myosin, actin and parasite extracts. The eluted antibodies bound the same Ag. When IgG were further analyzed by Western blot on proteolytic fragments of tubulin, we found that antibodies from both groups bound to the same broad spectrum of polypeptide bands. However, additional fragments were recognized by antibodies from infected mice. All these results indicate that the autoantibodies naturally present in mice are significantly affected after infection with T. cruzi, in quantity as well as in specificity and affinity.  相似文献   

9.
A total of 150 human sera was used to evaluate a commercial latex agglutination kit for detecting antibodies to the lipopolysaccharide of Escherichia coli O157. A comparison of the kit with SDS-PAGE and immunoblotting showed that the kit had a sensitivity of 94.12%, a specificity of 99.15%, a positive predictive value of 96.97% and a negative predictive value of 99.15%.  相似文献   

10.
11.
Patients with chronic helminth infections, despite having abundant basophils and mast cells specifically sensitized with antiparasite IgE and often exposed repeatedly to parasite Ag, rarely manifest allergic symptoms. This control of clinical allergic reactivity likely results from Ag-specific IgG "blocking antibodies" shown previously to be abundant in the sera of such patients. In the present study we used two approaches to determine in which of the four IgG subclasses this blocking activity was localized. First, specific antifilarial antibodies of each of the four IgG subclasses were quantified in the sera of 28 patients with Bancroftian filariasis and correlated with the levels of blocking activity in these sera (determined by histamine release assays). A significant correlation with blocking activity was seen only for antibodies of the IgG4 subclass, and, indeed, the correlation was especially strong in the group of totally asymptomatic patients (but with microfilariae circulating in the blood) in whom blocking antibody levels were highest. Interestingly, however, if the analysis excluded these asymptomatic microfilaremic patients and focused instead on those with lymphatic inflammatory pathology (who had relatively low levels of both serum blocking activity and specific IgG4 antibodies), then the small amount of blocking activity found in these sera correlated only with the levels of IgG1 subclass antibodies. The second approach utilized selective depletion of IgG4 (by anti-IgG4 affinity columns) from the sera of three microfilaremic patients with high levels of blocking activity and demonstrated clearly that removal of IgG4 abolished the majority of the blocking activity in these sera (53, 78, and 81%). These two sets of findings demonstrate a predominant role for specific IgG4 antibodies in blocking IgE-mediated allergic responses to the parasite Ag in vitro, but they also indicate that in some situations IgG1 antibodies can block such reactions. Furthermore, the correlation demonstrated between patients' clinical presentations and the levels of both their specific IgG4 antibodies and serum blocking activity suggests that these antibodies play a similar role in vivo as well.  相似文献   

12.
The precise diagnosis of the acute toxoplasmosis in pregnant women and immunocompromsied patients has critical importance. Most of the commercially available assays use the whole Toxoplasma soluble extract as the antigen. However, the assays currently available for the detection of specific anti-Toxoplasma antibodies may vary in their abilities to detect serum immunoglobulins, due to the lack of a purified standardized antigen. The aim of this study was production and evaluation of the usefulness of the recombinant Toxoplasma gondii GRA7 antigen for the serodiagnosis of Toxoplasma gondii IgM and IgG by ELISA. A total of 70 T. gondii IgM positive sera, 74 T. gondii IgG positive sera, and 60 sera from subjects who were not infected with T. gondii were examined. These sera were shown different absorbance values in ELISA test. To control the specificity of the rGRA7 other parasitic diseases, for example, echinococcosis, malaria, leishmaniasis, fascioliasis, and strongyloidiasis were tested of which none showed positive results. Sensitivity and specificity of the generated recombinant IgG ELISA in comparison with commercial ELISA (com ELISA) were 89% and 90%, and the sensitivity and specificity of the generated recombinant IgM ELISA were 96% and 90%, respectively. The results obtained here show that this antigen is useful for diagnostic purposes.  相似文献   

13.
We present a rapid surface plasmon resonance-based serological assay for the detection of Salmonella Typhimurium infection in pigs using the Plasmonic((R)) SPR device. Lipopolysaccharide (LPS, 10 microg mL(-1)) from Salmonella Typhimurium was immobilised by self-assembly on a hydrophobic SPR chip. Using this LPS-coated chip, it was possible to bind and detect the anti-Salmonella Typhimurium antibodies in serum of pigs infected with the bacteria. The developed SPR assay is able to differentiate between sera obtained from pigs having low, medium, and high levels of Salmonella infection. A commercial ELISA kit was used to classify the sera for levels of Salmonella infection on the basis of optical density (OD%). A strong positive correlation was observed between the SPR-based assay and the ELISA (n=38, r=0.90, p<0.01). The sensitivity and specificity of the assay are 0.93 and 0.87, respectively. The SPR-based assay is label-free and does not require any sample preparation or dilution steps. The total analysis time is 45 min for each serum sample. The assay was found to be specific for Salmonella Typhimurium and shows no cross-reactivity to Salmonella Choleraesuis or Escherichia coli antibodies. As no sample preparation is required the developed assay has the potential to be used as a reliable tool for Salmonella monitoring programmes in pork production.  相似文献   

14.
Two microimmunofluorescence (MIF) tests were compared for detection of antibodies to Chlamydia pneumoniae: the microimmunofluorescence of Washington University and the microimmunofluorescence of Chlamydia Serofia. Concordant positive results at the same dilution were observed for IgG in 37.33% of sera tested and concordant negative results were found in 44%. Variations of one fold dilution were observed in 36 sera. Extensive variations (2-3 two-fold dilutions) in the numeric titer values were observed in 20 serum samples with titers of antibody generally higher in the Chlamydia Serofia MIF than in the Washington MIF, resulting in a diagnosis of current infection in three patients. IgM were found with both methods only in one patient. The discrepancies observed may be due to several factors including the different TWAR strain used as antigen in the two tests and the dilution of the FITC-labelled conjugated anti-human IgG.We think that MIF serology may also be influenced by the type of response of the host that may depend on the "local strain" of C. pneumoniae that may express different antigens or in different amounts in comparison with the strains used by the commercial kit.  相似文献   

15.
The results of comparative study of sera obtained from donors and from several groups of patients with suspected toxoplasmosis are presented. The study has been carried out with the use of commercial enzyme immunoassay (EIA) kits: Toxoplasma gondii IgG EIA and Toxoplasma gondii IgM EIA manufactured by Labsystems (Finland), Sevatest ELISA IgG Toxo Micro I manufactured by Sevac (Czechoslovakia). Statistical processing of the results has confirmed the identity of these kits. The necessity of using evaluation criteria (the separation point, the scale for the interpretation of results) when working with the Sevac kits is emphasized. Comparative evaluation of antibody profiles in the sera under test suggests that the titer less than 1:1600 should be regarded as the separation point for these kits. IgM antibodies to T. gondii have been found only in 22% of patients with high titers of IgG antibodies.  相似文献   

16.
An indirect form of protein-A ELISA (PAI-ELISA) was optimized and, when used to detect anti-Smith antibodies in sera of 31 systemic lupus erythematosus (SLE) patients, gave results comparable with those using a commercial immunodiffusion kit. The number of sera found to be positive for anti-Smith antibodies by ELISA was seven, four of which were also found positive by immunodiffusion.B.O. Siti-Rohana is with the Universiti Kebangsaan Malaysia (UKM), Faculty of Medicine, Kuala Lumpur, Malaysia. I.B. Ahmad is with the Department of Microbiology, Faculty of Life Sciences, Universiti Kebangsaan Malaysia, Bangi, 43600 UKM, Malaysia; B.A. Nasaruddin is with the Institute for Medical Research, Malaysia.  相似文献   

17.
African swine fever virus (ASFV) infection is a big threat to the global pig industry. Because there is no effective vaccine, rapid, low-cost, and simple diagnosis methods are necessary to detect the ASFV infection in pig herds. Nanobodies, with advantages of small molecular weight and easy genetic engineering, have been universally used as reagents for developing diagnostic kits. In this study, the recombinant ASFV-p30 was expressed and served as an antigen to immunize the Bactrian camel. Then, seven nanobodies against ASFV-p30 were screened using phage display technique. Subsequently, the seven nanobodies fused horseradish peroxidase (nanobody-HRP) were secretory expressed and one fusion protein ASFV-p30-Nb75-HRP was selected with the highest sensitivity in blocking ELISA. Using the ASFV-p30-Nb75-HRP fusion protein as a probe, a competitive ELISA (cELISA) was developed for detecting anti-ASFV antibodies in pig sera. The cut-off value of cELISA was determined to be 22.7% by testing 360 negative pig sera. The detection limit of the cELISA for positive pig sera was 1:320, and there was no cross-reaction with anti-other swine virus antibodies. The comparative assay showed that the agreement of the cELISA with a commercial ELISA kit was 100%. More importantly, the developed cELISA showed low cost and easy production as a commercial kit candidate. Collectively, a simple nanobody-based cELISA for detecting antibodies against ASFV is developed and it provides a new method for monitoring ASFV infection in the pig herds.  相似文献   

18.
The prevalence of chronic Toxoplasma infections reported in the literature varies enormously. We hypothesize that one factor could be due to the different methods used in the evaluation of infections. Serological evidence of Toxoplasma infections in 450 pregnant women (PW) and 300 HIV-infected patients (HIV) were investigated by the Sabin–Feldman dye test and two other commercial ELISA kits (kit1 and kit2). Anti-Toxoplasma IgG antibodies obtained from the Sabin–Feldman dye test, ELISA kit1 and ELISA kit2 in the PW subjects were 14.7%, 29.6% and 38.7%, and in the HIV subjects were 13%, 34.7% and 36.3%, respectively. So there were significant differences in the seroprevalences when different diagnostic tests were used (P < 0.05). Regarding Sabin–Feldman dye test as the gold standard for anti-Toxoplasma antibodies detection, we found that the sensitivity and specificity of the ELISA kit1 and kit2 was in the range of their specification. However as the two ELISA kits used in our study identified a much higher prevalence of Toxoplasma infections which indicated that false positive cases were being reported. Based on results obtained, it is therefore highly recommended that research workers should be aware that the reports of serological studies in terms of high positive results should be treated with some skepticism until additional precise diagnostic tools are developed.  相似文献   

19.
A new and label-free capacitive immunosensor based on antibody-functionalized epoxysilane on a glassy carbon electrode has been developed for quantitative detection of human chorionic gonadotropin (hCG). Monitoring the changes in the capacitance signals of antibodies before and after the binding of the antigen provides the basis for an immunoassay. The performance and factors influencing the immunosensor were also studied. Under the optimized conditions, the developed immunosensor quantitatively detected serum hCG in the range of 18–450 mIU/ml with a detection limit of 5.0 mIU/ml (at 3δ). Thirty-five patients’ sera were assayed by the proposed immunosensor, and the results agreed with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.998. Further research about the intrinsic electroactivity of antibodies and their target molecules would surely provide new and sensitive screening assays as well as extensive data regarding their interaction mechanisms.  相似文献   

20.
An enzyme-linked immunosorbent-inhibition assay for quantitation of hyaluronic acid (HA) is described. The principle of the method depends on the specific binding of HA to the hyaluronic acid-binding region (HABR) of proteoglycan (PG) monomers. The remaining uncomplexed PG monomers were determined by incubation with specific monoclonal antibodies to HABR followed by addition of polyclonal antibodies against PG monomers and enzyme-conjugated antibodies. The HA in samples was quantified by comparing their inhibitory capacity in the assay against a standard inhibition curve obtained using highly purified HA. This method was used to quantitate HA at nanogram levels in normal sera and synovial fluids. The level in normal human sera was found to be 28 +/- 17 ng/ml which compared favorably with values obtained using a commercial radioassay kit on the same samples. The assay was used to measure HA in synovial fluid from patients with rheumatoid and osteoarthritis and the results obtained were comparable with data published by others.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号