首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the simultaneous determination of de(N-methyl)-N-ethyl-8,9-anhydroerythromycin A 6,9-hemiacetal (EM523, I) and its three metabolites in human plasma and urine has been developed using high-performance liquid chromatography (HPLC) with chemiluminescence (CL) detection. Plasma and urine samples spiked with erythromycin as an internal standard were extracted with a mixture of dichloromethane and diethyl ether under alkaline conditions. The ortanic layer was evaporated under a stream of nitrogen gas. The reconstituted sample was injected into an HPLC apparatus and separated on an ODS column using a gradient elution method. The elute was reacted on-line with a mixture of tris(2,2′-bipyridine) ruthenium(II) and peroxodisulfate, and the generated CL intensity was detected. Optimization of the CL reaction conditions resulted in a sensitive and stable CL intensity for the determination of I and its metabolites. The recovery of each compound from human plasma and urine, and the sensitivity, linearity, accuracy and precision of the method were satisfactory. The lower limits of quantitation for each compound using 0.2 ml of plasma and 0.1 ml of urine were 1 and 00 ng/ml, respectively. This method has been used for the determination of I in samples from clinical trials.  相似文献   

2.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

3.
The novel compound methyl-1-(3,4-dimethoxyphenyl)-3-(3-ethylvaleryl)-4-hydroxy-6,7,8-trimethoxy-2-naphthoate (S-8921) has hypocholesterolemic activity in animals and is expected to exhibit a similar activity in human. Reversed-phase high-performance liquid chromatography (HPLC) separation followed by radioimmunoassay (RIA) for human plasma samples (HPLC–RIA) and immunoaffinity extraction (IAE) followed by RIA for human urine samples (IAE–RIA) were developed for investigation of S-8921 behavior in clinical studies. For the RIA, antisera from rabbit and a radioiodine-labelled S-8921 were prepared by immunizing a conjugate of S-8921 with bovine serum albumin and by the Bolton and Hunter method, respectively. HPLC–RIA using a semi-micro column was very sensitive, that is a 0.05 ng/ml limit of quantitation in human plasma, and specific for unchanged form of S-8921. IAE–RIA using a centrifugal filtration tube completely eliminated the matrix effect of human urine, and was very feasible. The limit of quantitation was 0.10 ng/ml. RIA detection following HPLC or IAE proved to be very useful for the pharmaceutical analysis of extremely low drug concentrations in body fluids.  相似文献   

4.
A simple, sensitive and specific automated SPE-LC-MS-MS assay was developed and validated for determination of valdecoxib (I), its hydroxylated metabolite (II) and carboxylic acid metabolite (III) in human urine. The analytes (I, II and III) and a structural analogue internal standard (I.S.) were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was performed on a narrow-bore reverse phase HPLC column with a mobile phase of acetonitrile-water (50:50, v/v) containing 10 mM 4-methylmorpholine (pH 6.0). The analytes were ionized using negative electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 313-->118, m/z 329-->196 and m/z 343-->196 were used to measure I, II and III, respectively. The assay exhibited a linear dynamic range of 1-200 ng/ml for I and II and 2-200 ng/ml for III in human urine. The lower limit of quantitation was 1 ng/ml for I and II and 2 ng/ml for III. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 5.5 min for each sample made it possible to analyze a throughput of 70 human urine samples per run. The assay has been successfully used to analyze human urine samples to support clinical phase I and II studies.  相似文献   

5.
9-(3-Pyridylmethyl)-9-deazaguanine (BCX-34), a new purine nucleoside phosphorylase inhibitor, has selective immunosuppressive activity with potential therapeutic value in T-cell-mediated diseases. We now report a sensitive, specific and reproducible method for measurement of 9-(3-pyridylmethyl)-9-deazagunanine in biological fluids using high-performance liquid chromatography (HPLC). 9-(3-Pyridylmethyl)-9-deazagunanine was extracted from plasma using perchloric acid precipitation followed by passage through Sep-Pak C18 cartridges (average extraction efficiency, 64.6%). Standard curves were linear over the range of interest (28–1120 ng/ml in plasma and 200–4000 ng/ml in urine, r2>0.999). Within-day and between-day coefficients of variation were less than 8%. The limit of quantitation was 28 ng/ml in plasma and 200 ng/ml in urine. This HPLC method should be useful in future clinical studies with this drug.  相似文献   

6.
A sensitive reversed-phase high-performance liquid chromatographic fluorescence method is described for the simultaneous determination of topotecan (I) and the hydrolysed lactone ring-opened product hydroxy acid (II) in plasma and for the determination of I in urine. To 250 μl of plasma, a 750-μl volume of cold methanol was added to stabilize the pH-dependent conversion of I into II. In plasma, the lower limit of quantitation (LLQ) for both compounds was 0.10 ng/ml. The between-day variation for I at the LLQ was 7.1% and for II was 5.5%. Prior to injection, urine samples were acidified with orthophosphoric acid and diluted with phosphate-buffered saline (PBS). In urine, the calibration curve for I was linear in the range of 10 to 250 ng/ml and the LLQ was 10 ng/ml. The assay was developed to enable pharmacological analysis of I, in on-going phase I and II studies, in patients with solid tumors.  相似文献   

7.
Doxepin is a tricyclic antidepressant marketed as an irrational mixture of cis- and trans-geometric isomers in the ratio of 15:85. A convenient high-performance liquid chromatographic (HPLC) procedure for simultaneous quantitation of geometric isomers of doxepin and N-desmethyldoxepin in plasma and urine is described. The HPLC procedure employed a normal phase system with a silica column and a mobile phase consisting of hexane-methanol-nonylamine (95:5:0.3, v/v/v), a UV detector and nortriptyline as the internal standard. The liquid-liquid extraction solvent was a mixture of n-pentane-isopropanol (95:5, v/v). The limit of quantitation was 1 ng/ml for each isomer. The calibration curves were linear over the ranges 1–200 ng/ml (plasma) and 1–400 ng/ml (urine). In plasma, the accuracy (mean±S.D.) (97.53±1.67%) and precision (3.89±1.65%) data for trans-doxepin were similar to corresponding values for urine, i.e., 97.10±2.40 and 3.82±1.14%. Accuracy and precision data for trans-N-desmethyldoxepin in plasma were 97.57±2.06 and 4.38±3.24%, and in urine were 97.64±3.32 and 5.26±1.83%, respectively. Stability tests under three different conditions of storage indicated no evidence of degradation. The recovery of doxepin was 61–64% from plasma and 63–68% from urine. The method has been applied to analyses of plasma and urine samples from human volunteers and animals dosed with doxepin.  相似文献   

8.
A rapid, sensitive and specific normal-phase (adsorption) high-performance liquid chromatographic (HPLC) assay was developed for the determination of 1-(2-aminoethyl)-3-(2,6-dichlorophenyl)thiourea [I] in plasma and urine. The assay involves the extraction of the compound into methylene chloride from plasma or urine buffered to pH 10, and the HPLC analysis of the residue dissolved in methylene chloride—methanol—heptane (85:10:5). A 10-μm silica gel column was used with methylene chloride—methanol—heptane—ammonium hydroxide (85:10:5:0.1) as the eluting solvent. The effluent was monitored at 254 nm and quantitation was based on the peak height vs. concentration technique. The assay has a recovery of 64.5 ± 4.5% (S.D.) from plasma and 96.0 ± 6.3% (S.D.) from urine in the concentration range of 0.1–2 μg per ml and 2–40 μg per 0.1 ml of plasma and urine, respectively, with a limit of detection of 0.05–0.1 μg [I] per ml of plasma using a 1-ml specimen and 0.1 μg per ml urine using a 0.1-ml specimen, respectively. The assay was applied to the determination of plasma levels and urinary excretion of the compound [I] in dog following the oral administration of 28.8 mg of [I] · maleate per kg body weight.The HPLC assay was also used to determine the stability of [I] and for the measurement of a potential degradation product, clonidine [II] [2-(2,6-dichlorophenylamino)-2-imidazoline] in pooled human plasma stored at ?17°C, and pooled human urine stored at ?17°C and ?90°C, respectively.  相似文献   

9.
A sensitive and specific high performance liquid chromatographic method for quantitation of topiramate in human serum was developed using HPLC with fluorescence labeling reagent. Topiramate was extracted from human serum by dichloromethane and derivatized by reaction with 9-fluorenylmethyl chloroformate (FMOC-Cl) in the presence of borate buffer. Analysis was performed on a CN column with sodium phosphate buffer (pH 2.2) containing 1 ml/l triethylamine and methanol (52:48 (v/v)) as mobile phase. Amantadine was used as internal standard. The standard curve was linear over the range 20-5000 ng/ml of topiramate in human serum. The mean intra-day precision was from 10.5% (low concentration) to 1.2% (high concentration) and the within-day precision from 1.5 to 12.5% determined on spiked samples. The accuracy of the method was 96.5-107.5% (intra-day) and 98.4-105% (inter-day). The limit of quantification was 20 ng/ml of serum. This method was used in a bioequivalence study after administration of 2 x 25 mg topiramate in 24 healthy volunteers.  相似文献   

10.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

11.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

12.
A sensitive and specific HPLC-MS-MS method was developed for the determination of endogenous uracil (Ura) and its metabolite dihydrouracil (UH2) in human plasma and urine samples. Plasma samples were extracted with ethyl acetate-isopropanol (85:15, v/v) following added ammonium sulfate, and then separated on a Discovery Amide C16 column with 3% methanol solution as the mobile phase; urine samples were just centrifuged at 2500 g for detection. Quantitation was carried out by LC-MS-MS in the multiple reaction monitoring (MRM) mode. The limits of quantitation of the method for Ura and UH2 were 0.5 and 5 ng ml(-1) (for plasma), and 50 and 100 ng ml(-1) (for urine), respectively. This method can be useful to evaluate the activity of dihydropyrimidine dehydrogenase (DPD), a rate-limiting enzyme of the chemotherapy drug fluoropyrimidine, which will be helpful in investigating subject variation of DPD and adjusting clinical dosage in pyrimidine chemotherapy.  相似文献   

13.
A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.  相似文献   

14.
A high performance liquid chromatography (HPLC) method for the estimation of pravastatin in human plasma and urine samples has been developed. The preparation of the samples was performed by automated solid phase extraction using clonazepam as internal standard. The compounds were separated by isocratic reversed-phase HPLC (C(18)) and detected at 239 nm. The method was linear up to concentrations of 200 ng/ml in plasma and 2000 ng/ml in urine. The intra-assay variability for pravastatin in plasma ranged from 0.9% to 3.5% and from 2.5% to 5.3% in urine. The inter-assay variability ranged from 9.1% to 10.2% in plasma and from 3.9% to 7.5% in urine. The validated limits of quantification were 1.9 ng/ml for plasma and 125 ng/ml for urine estimation. These method characteristics allowed the determination of the pharmacokinetic parameters of pravastatin after administration of therapeutic doses.  相似文献   

15.
A high-performance liquid chromatographic assay method for the quantitation of ipecac alkaloids (cephaeline and emetine) in human plasma and urine is described. Human plasma or urine was extracted with diethylether under alkaline conditions following the addition of an internal standard. Concentrations of alkaloids and internal standard were determined by octadecylsilica chromatographic separation (Symmetry C18 columns, plasma analysis; 15 cm×4.6 mm I.D., 5 μm particle size, urine analysis; 7.5 cm×4.6 mm I.D., 5 μm particle size). The mobile phase consisted of buffer (20 mmol/l 1-heptanesulfonic acid sodium salt, adjusted to pH 4.0 with acetic acid)–methanol (51:49, v/v). Eluate fluorescence was monitored at 285/316 nm. The lowest quantitation limits of cephaeline and emetine were 1 and 2.5 ng/ml, respectively, in plasma, and 5 ng/ml in urine. Intra- and inter-day relative standard deviations were below 15%. The assay is sensitive, specific and applicable to pharmacokinetic studies in humans.  相似文献   

16.
A rapid, selective and highly sensitive reversed-phase high-performance liquid chromatography (HPLC) method was developed for the determination of levosulpiride, 5-(aminosulfonyl)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-2-methoxy benzamide, in human serum and urine. The method involved the extraction with a dichloromethane followed by back-extraction into 0.025 M sulfuric acid. HPLC analysis was carried out using reversed-phase isocratic elution with a Luna C(18)(2) 5 microm column, a mobile phase of acetonitrile-0.01 M potassium hydrogen phosphate (30:70, v/v, adjusted to pH 8.5 with triethylamine), and a fluorescence detector with excitation at 300 nm and emission at 365 nm. The chromatograms showed good resolution and sensitivity and no interference of human serum and urine. The calibration curves were linear over the concentration range 0.25-200 ng/ml for serum and 0.2-20 microg/ml for urine with correlation coefficients greater than 0.997. Intra- and inter-day assay precision and accuracy fulfilled the international requirements. The mean absolute recovery for human serum was 89.8+/-3.7%. The lower limits of quantitation in human serum and urine were 0.25 ng/ml and 0.2 microg/ml, respectively, which were sensitive enough for pharmacokinetic studies. Stability studies showed that levosulpiride in human serum and urine was stable during storage, or during the assay procedure. This method was successfully applied to the study of pharmacokinetics of levosulpiride in human volunteers following a single oral administration of levosulpiride (25 mg) tablet.  相似文献   

17.
A high-performance liquid chromatographic method was developed for the determination of a new podophyllotoxin derivative, TOP-53 (I), and TOP-53 glucoronide (II) as its major metabolite in rat plasma and urine. For the analysis of I, the sample was chromatographed on a reversed-phase C18 column with electrochemical detection after consecutive two-step liquid-liquid extractions. Compound II was determined as I after enzymatic hydrolysis of II. This method was validated sufficiently with respect to specificity, accuracy, and precision. The limiits of quantitation for both I and II were 2 ng/ml in plasma and 10 ng/ml in urine. The method is thus useful for the pharmacokinetic study of I.  相似文献   

18.
A sensitive gradient high-performance liquid chromatographic (HPLC) method for the simultaneous quantitation of a dopamine autoreceptor agonist CI-1007 (I) and its metabolite PD 147693 (II) is described. Monkey plasma samples were purified by liquid-liquid extraction using hexane. Liquid chromatographic separation was achieved on two C18 analytical columns (installed in series) using gradient elution. Column effluent was monitored using a fluorescence detector programmed to change wavelengths at specified times. Minimum quantitation limits of I and II were 3.0 and 5.0 ng/ml, respectively, for a plasma sample volume of 0.100 ml. Linearity was demonstrated up to 300 ng/ml. The assay has been applied to the analysis of I and II in plasma from monkeys following intravenous and oral doses of I.  相似文献   

19.
A rapid, selective and reproducible high-performance liquid chromatographic (HPLC) method with ultraviolet detection was developed for the determination of the anti-cancer agent Taxotere in biological fluids. The method involves a solid-phase extraction step (C2 ethyl microcolumns) using a Varian Advanced Automated Sample Processor (AASP) followed by reversed-phase HPLC. The validated quantitation range of the method is 10–2500 ng/ml in plasma with coefficients of variation ≤ 11%. The method is also suitable for the determination of Taxotere in urine samples under the same conditions. The method was applied in a phase I tolerance study of Taxotere in cancer patients, allowing the pharmacokinetic profile of Taxotere to be established.  相似文献   

20.
We developed a sensitive and selective method for determining levels of sultopride, a neuroleptic drug of the substituted benzamide, in human plasma using high-performance liquid chromatography (HPLC) combined with UV detection and particle beam mass spectrometry (PBMS). Sutopride was extracted with tert.-butylmethyl ether using a salting-out technique. Tiapride served as an internal standard (I.S.). Sutopride and I.S. were separated by HPLC on a silica column with a mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear over the concentration range from 5 to 1000 ng/ml by HPLC with UV detection and from 10 to 1000 ng/ml with PBMS detection. The limit of quantitation was 5 ng/ml with UV detection and 10 ng/ml with PBMS detection. The absolute recovery was 92% and the within-day coefficients of variation were 2.9–7.1% at plasma concentrations from 50 to 500 ng/ml, determined by HPLC with UV detection. Using this method, we measured the plasma concentrations of sultopride with replicate analyses in four hospitalized patients and steady-state plasma levels were determined to be 161.6±30.8, 321.1±93.7, 726.5±143.1 and 1273.6±211.2 ng/ml, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号