首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In the present study, three methods (NucliSens miniMAG [bioMérieux], MagNA Pure DNA Isolation Kit III Bacteria/Fungi [Roche], and a silica-guanidiniumthiocyanate {Si-GuSCN-F} procedure for extracting DNA from stool specimens were compared with regard to analytical performance (relative DNA recovery and down stream real-time PCR amplification of Salmonella enterica DNA), stability of the extracted DNA, hands-on time (HOT), total processing time (TPT), and costs. The Si-GuSCN-F procedure showed the highest analytical performance (relative recovery of 99%, S. enterica real-time PCR sensitivity of 91%) at the lowest associated costs per extraction (euro 4.28). However, this method did required the longest HOT (144 min) and subsequent TPT (176 min) when processing 24 extractions. Both miniMAG and MagNA Pure extraction showed similar performances at first (relative recoveries of 57% and 52%, S. enterica real-time PCR sensitivity of 85%). However, when difference in the observed Ct values after real-time PCR were taken into account, MagNA Pure resulted in a significant increase in Ct value compared to both miniMAG and Si-GuSCN-F (with on average +1.26 and +1.43 cycles). With regard to inhibition all methods showed relatively low inhibition rates (< 4%), with miniMAG providing the lowest rate (0.7%). Extracted DNA was stable for at least 1 year for all methods. HOT was lowest for MagNA Pure (60 min) and TPT was shortest for miniMAG (121 min). Costs, finally, were euro 4.28 for Si-GuSCN, euro 6.69 for MagNA Pure and euro 9.57 for miniMAG.  相似文献   

2.
The polymerase chain reaction was used to detect clinical samples of Mycoplasma pneumoniae. A 245-bp region of the cytoadhesin P1 gene was shown to be specifically amplified in Myc. pneumoniae , but not in other species of Mollicutes. Picogram amounts of Myc. pneumoniae DNA could be detected per ml blood serum by use of a simple and reliable protocol for sample preparation and a PCR reaction involving two rounds of amplification. Application of the PCR-based method for the detection of Myc. pneumoniae in serum samples and throat swabs from patients with atypical pneumonia showed that it could be used in clinical diagnosis.  相似文献   

3.
We designed a multiplex real time PCR for rapid, sensitive and specific detection of Streptococcus pneumoniae, Legionella pneumophila, Chlamydophila pneumoniae and Mycoplasma pneumoniae. The study cases consisted of 129 patients with community acquired pneumonia (CAP). Bacteriological techniques were implemented for detection of the cultivable organisms. DNA were extracted from sputa, throat swabs, bronchoalveolar lavages and tracheal aspirates and used as templates in real time PCR. The primers and probes were designed for cbpA (S. pneumoniae), p1adhesin (M. pneumoniae), mip (L. pneumophila) and ompA (C. pneumoniae). After optimization of real time PCR for every organism, the experiments were continued in multiplex in a single tube. Of 129 CAP specimens, the positive cultures included 14 (10.85%) for S. pneumoniae, 9 (6.98%) for L. pneumophila and 3 (2.33%) for M. pneumoniae. Four specimens (3.10%) were positive for C. pneumoniae by real time PCR. The sensitivity of our real time PCR was 100% for all selected bacteria. The specificity of the test was 98.26%, 98.34%, 100% and 100% for S. pneumoniae, L. pneumophila, M. pneumoniae and C. pneumoniae, respectively. This is the first report on the use of multiplex real time PCR for detection of CAP patients in the Middle East. The method covers more than 90% of the bacterial pathogens causing CAP.  相似文献   

4.
In this study we compared the QIAsymphony Sample Preparation and Assay Setup modules (Qiagen), which provide automated nucleic acid extraction and PCR setup, to the NucliSens easyMAG (bioMérieux) and CAS-1200 liquid handling station1 (Corbett) for a molecular screening approach of enteric pathogens in fecal samples using multiplex real-time PCR. The relative DNA recovery of both platforms, within- and between-run reproducibility and a prospective study, including 510 clinical fecal samples, were performed. The results demonstrated that the QIAsymphony Sample Preparation and Assay Setup modules were highly reproducible and achieve equal performance, quantitative and qualitative, when compared with the NucliSens easyMAG and CAS-1200 systems for the molecular screening analysis of enteric pathogens in fecal samples.  相似文献   

5.
This study evaluated five commercial extraction kits for their ability to recover DNA from Bacillus anthracis spores and spiked environmental samples. The kits evaluated represent the major types of methodologies which are commercially available for DNA or total nucleic acid extraction, and included the ChargeSwitch gDNA Mini Bacteria Kit, NucliSens Isolation Kit, Puregene Genomic DNA Purification Kit, QIAamp DNA Blood Mini Kit, and the UltraClean Microbial DNA Isolation Kit. Extraction methods were performed using the spores of eight virulent strains of B. anthracis. Viability testing of nucleic acid extracts showed that the UltraClean kit was the most efficient at depleting samples of live B. anthracis spores. TaqMan real-time PCR analysis revealed that the NucliSens, QIAamp and UltraClean kits yielded the best level of detection from spore suspensions. Comparisons of processed samples from spiked swabs and three powder types indicated that DNA extraction using the UltraClean kit resulted in the most consistently positive results and the lowest limit of detection. This study demonstrated that different nucleic extraction methodologies, represented here by various commercial extraction kits, differ in their ability to inactivate live B. anthracis spores as well as DNA yield and purity. In addition, the extraction method used can influence the sensitivity of real-time PCR assays for B. anthracis.  相似文献   

6.
A commercially available nucleic acid sequence-based amplification (NASBA) NucliSens Basic Kit (NBK) assay for the detection of Mycoplasma pneumoniae 16S rRNA in respiratory specimens was developed and compared to standard NASBA and PCR assays previously developed in our laboratory. The specificity and sensitivity of the NBK assay was comparable to the specificity and sensitivity of the corresponding standard NASBA assay. The NBK offers standardized reagents for the development of a NASBA assay for the detection of M. pneumoniae in respiratory specimens and is easily adaptable to other amplification targets.  相似文献   

7.
[目的]克隆和表达肺炎嗜衣原体(Chlamydophila pneumoniae,Cpn)蛋白酶样活性因子(CPAF)免疫优势区基因,评价重组蛋白在早期感染诊断中的应用价值.[方法]挑选并克隆出Cpn CPAF免疫优势区基因,构建原核表达载体,诱导表达并纯化重组蛋白,分析其抗原特异性;间接ELISA法检测Cpn参考血清、临床血清标本中的特异性IgM抗体,以及呼吸道感染患者痰咽拭子中的Cpn抗原;检测沙眼衣原体(Chlamydia trachomatis,Ct)临床阳性血清和泌尿生殖道分泌物.[结果]高效表达和纯化出一相对分子量约51.3kDa的重组蛋白;Western blot证明其只与人抗Cpn抗血清发生特异性反应;间接ELISA法检测40份Cpn IgM参考血清,阴性和阳性结果的一致率均为100%(40/40);与"金标准"方法MIF对照,检测300例临床血清标本中的IgM抗体,符合率为98.3%;与PCR试剂对照,检测120份呼吸道感染患者痰咽拭子中的Cpn抗原,符合率为88.3%;检测Ct阳性血清和泌尿生殖道分泌物,与Ct没有交叉反应.[结论]制备的CPAF免疫优势区基因重组蛋白具有良好的抗原性,在Cpn感染早期诊断中具有较高的利用价值.  相似文献   

8.
The fast diagnosis of Mycoplasma primary atypical pneumonia is impaired by the lack of routinely available culture methods for isolation of Mycoplasma pneumoniae from clinical specimens. Likewise, serological methods commonly used for diagnosis are insensitive and non-specific. In this study, we have established and applied the polymerase chain reaction (PCR) technique to detect M. pneumoniae DNA in clinical samples originating from the respiratory tract. The PCR results were compared with those from culture and serology tests. To standardize the detection of M. pneumoniae by PCR, we first used DNA from culture grown organisms and clinical samples seeded with M. pneumoniae. PCR amplification was performed with M. pneumoniae-specific primers to amplify 144, 153 and 631 bp DNA fragments by using primer pairs MP5-1/MP5-2, P1-178/P1-331 and P1-178/P1-809, respectively. The amplification of the 631 bp DNA fragment was found to be most sensitive for the detection of M. pneumoniae. Using the most sensitive PCR, a total of 47 respiratory specimens from patients suspected of community acquired pneumonia were tested. While none of the specimens were positive for M. pneumoniae in culture, 6 specimens gave positive results by PCR. In 4 out of the 5 PCR positive samples tested serologically, the results were supported by elevated levels of anti-mycoplasma IgG/IgM/IgA. Thus, these results suggest that PCR is the most sensitive method to detect M. pneumoniae in clinical specimens.  相似文献   

9.
目的比较液体培养法和固体培养法平行检测肺炎支原体结果的一致性;评价液体培养法检测肺炎支原体的可靠性。方法采用液体培养基和固体琼脂培养基平行检测1 648份临床标本的肺炎支原体,比较同一份标本在2种培养基上的检测结果。结果液体培养法阳性296例,阳性率为18%;固体培养法阳性244例,阳性率为14.8%;液体培养法阳性而固体培养法阴性57例;固体培养阳性而液体培养法为阴性5例。2种方法的阳性检出率比较差异有统计学意义(P<0.05)。结论肺炎支原体快速液体培养法与固体培养有较好的一致性,具有方便、简单、准确且可以用于早期检测等优点,适合临床大批量标本筛查。需结合患者临床症状等排除真菌和耐药菌造成的假阳性。  相似文献   

10.
The prokaryote Mycoplasma pneumoniae is a major cause of respiratory disease in humans, accounting for 20% of all community-acquired pneumonia and the leading cause of pneumonia in older children and young adults. The limitations of existing options for mycoplasma diagnosis highlight a critical need for a new detection platform with high sensitivity, specificity, and expediency. Here we evaluated silver nanorod arrays (NA) as a biosensing platform for detection and differentiation of M. pneumoniae in culture and in spiked and true clinical throat swab samples by surface-enhanced Raman spectroscopy (SERS). Three M. pneumoniae strains were reproducibly differentiated by NA-SERS with 95%-100% specificity and 94-100% sensitivity, and with a lower detection limit exceeding standard PCR. Analysis of throat swab samples spiked with M. pneumoniae yielded detection in a complex, clinically relevant background with >90% accuracy and high sensitivity. In addition, NA-SERS correctly classified with >97% accuracy, ten true clinical throat swab samples previously established by real-time PCR and culture to be positive or negative for M. pneumoniae. Our findings suggest that the unique biochemical specificity of Raman spectroscopy, combined with reproducible spectral enhancement by silver NA, holds great promise as a superior platform for rapid and sensitive detection and identification of M. pneumoniae, with potential for point-of-care application.  相似文献   

11.
For quantitative NASBA-based viral load assays using homogeneous detection with molecular beacons, such as the NucliSens EasyQ HIV-1 assay, a quantitation algorithm is required. During the amplification process there is a constant growth in the concentration of amplicons to which the beacon can bind while generating a fluorescence signal. The overall fluorescence curve contains kinetic information on both amplicon formation and beacon binding, but only the former is relevant for quantitation. In the current paper, mathematical modeling of the relevant processes is used to develop an equation describing the fluorescence curve as a function of the amplification time and the relevant kinetic parameters. This equation allows reconstruction of RNA formation, which is characterized by an exponential increase in concentrations as long as the primer concentrations are not rate limiting and by linear growth over time after the primer pool is depleted. During the linear growth phase, the actual quantitation is based on assessing the amplicon formation rate from the viral RNA relative to that from a fixed amount of calibrator RNA. The quantitation procedure has been successfully applied in the NucliSens EasyQ HIV-1 assay.  相似文献   

12.
为了解广州市儿童呼吸道支原体感染情况,用一条共同的上游引物,二条特异性的下游引物建立的PCR方法能同时扩增MP的691bp和MG的438bp粘附因子基因片段,但不会扩增其他支原体和细菌的DNA。  相似文献   

13.
Blooms of Karenia brevis, the red tide forming dinoflagellate in the Gulf of Mexico, cause a myriad of ecological and economic problems for coastal communities, including massive fish and mammal mortalities, and damage to tourism and fisheries/shellfish harvesting industries. There is a need for accurate detection and prediction of K. brevis blooms, including rapid and inexpensive monitoring of both water and shellfish meats to ensure the safety of shellfish harvested for human consumption. To address this issue, we have developed a protocol for easy field extraction of cellular RNA from water samples and coupled it with a handheld nucleic acid sequence-based amplification (NASBA) sensor that amplifies and detects target mRNA specific to the rbcL gene of K. brevis. This extraction protocol is a modified version of the Qiagen RNeasy Mini Kit spin protocol and requires no specialized equipment or training. Once extracted, the RNA is amplified and detected by NASBA in an in-house designed and produced handheld sensor that provides a real-time fluorescence plotting of the amplification. Both the field RNA extraction protocol and the handheld NASBA analyzer compared favorably to laboratory-based technologies. In duplicate reactions, the amplification curves generated with the handheld detector closely mirrored the curves generated with the bench top Nuclisens EasyQ NASBA analyzer and there was no difference in the sensitivity obtained using the handheld device versus the bench top models. This extraction protocol and detection sensor will be a valuable tool for rapidly monitoring K. brevis in field environments.  相似文献   

14.
目的同时用目前常用的几种诊断肺炎支原体(MP)感染的实验方法检测MP,相互比较,得出适于常规诊断MP感染的方法或组合。方法搜集我院于2006年10月至2007年5月间以呼吸道感染入院儿童病例75例,采集其咽拭子和双份血清标本,以多种方法检测有无MP感染:培养法、EIA法测抗原、PCR法测MP-DNA,ELISA法测MP特异性IgG、IgA型抗体以及捕获法ELISA测MP特异性IgM型抗体。结果上述75例儿童中,共计有12例感染MP。以此为基础,上述各方法的敏感度分别是:培养法(25%)、EIA法测抗原(8.3%)、PCR法测MP-DNA(75.0%)、ELISA法测MP特异性IgA型抗体(单份血清为0,双份血清为33.3%)、捕获法ELISA测MP特异性IgM型抗体(单份血清为66.7%,双份血清为100%)。特异度分别是:100%、96.8%、93.7%(93.7%)、98.4%(98.4%)。PCR法和捕获法ELISA测MP特异性IgM型抗体结合后敏感度和特异度分别达到100%和95.2%。结论PCR法测MP-DNA和捕获法ELISA测MP特异性IgM型抗体的组合可高效地诊断MP感染,因而可作为临床诊断MP感染的一个常规组合。  相似文献   

15.
We developed a real-time PCR to detect Mycoplasma pneumoniae with a primer set designed for the 16S rRNA gene. Clinical samples (n=937) were collected from children with community-acquired pneumonia between April 2002 and March 2004 at 12 Japanese medical institutions. Sensitivity of real-time PCR was calculated as 10 colony-forming units per reaction tube using a pMP01 plasmid carrying a 225-bp target DNA fragment of the 16S rRNA gene in M. pneumoniae M129, a standard strain. Results, obtained within 2 h, were compared with those of conventional culture and serologic methods. Of all cases tested, 151 (16.4%) and 129 (13.8%) were positive for M. pneumoniae by real-time PCR and by culture, respectively. Among the 151 cases, almost all of those tested serologically by passive agglutination showed a rise in M. pneumoniae antibody titre between acute and convalescent sera. We conclude that this real-time PCR can identify M. pneumoniae rapidly and fulfills the need for rapid identification, high sensitivity, and high specificity.  相似文献   

16.
We developed molecular diagnostic assays for the detection of Streptococcus pyogenes (GAS) and Streptococcus dysgalactiae subsp. equisimilis (SDSE), two streptococcal pathogens known to cause both pharyngitis and more invasive forms of disease in humans. Two real-time PCR assays coupled with an internal control were designed to be performed in parallel. One assay utilizes a gene target specific to GAS, and the other utilizes a gene target common to the two species. Both assays showed 2–3 orders of magnitude improved analytical sensitivity when compared to a commercially available rapid antigen test. In addition, when compared to standard culture in an analysis of 96 throat swabs, the real-time PCR assays resulted in clinical sensitivity and specificity of 91.7 and 100%, respectively. As capital equipment costs for real-time PCR can be prohibitive in smaller laboratories, the real-time PCR assays were converted to a low-density microarray format designed to function with an inexpensive photopolymerization-based non-enzymatic signal amplification (NESA™) method. S. pyogenes was successfully detected on the low-density microarray in less than 4 h from sample extraction through detection.  相似文献   

17.
Salmon eggs are common in Japanese sushi and other seafood products; however, certain fish eggs are used as counterfeit salmon eggs which are found in foods and processed products. This study develops a simple, rapid, and cost-effective method for DNA extraction, filtration (FT) and dilution (DL) protocols from a single salmon egg with good DNA quality for real-time PCR amplification. The DNA amount, DNA quality, and real-time PCR performance for different dilutions and different lengths of PCR amplicons were evaluated and compared with the common Qiagen tissue kit (QTK) and Chelex-100-based (CX) protocols. The extracted DNA from a single salmon egg using the FT or DL protocol can be applied in phylogenic research, food authentication and post-marketing monitoring of genetically modified (GM) food products.  相似文献   

18.
基于EMA-qPCR的茄科青枯菌活体检测技术的建立   总被引:1,自引:0,他引:1  
【目的】利用特异性核酸染料叠氮溴乙锭(Ethidium monoazide bromide, EMA)与实时荧光定量PCR技术相结合, 建立一种能有效区分青枯菌死活细胞的检测方法。【方法】样品DNA制备前经EMA渗透预处理, 再进行实时荧光定量PCR特异扩增菌体DNA。【结果】终浓度为2.0 mg/L的EMA能有效排除1.0×107 CFU/mL灭活青枯菌细胞DNA的扩增, 对活细胞和不可培养状态(Viable but non-culturable, VBNC)活菌的DNA扩增均没有影响。当每个定量PCR反应体系中的活细胞在5.0×100?5.0×104 CFU范围内时, 扩增Ct值与定量PCR反应体系中活细胞CFU对数值呈良好的负相关性(R2=0.992 5)。比较EMA-qPCR法和平板计数法对经过不同温度短期保存的青枯菌检测结果发现, 待检样品可在24 °C与4 °C冷藏条件下短期保存。【结论】本研究建立的EMA-qPCR方法能有效检测青枯菌VBNC细胞和有效区分死活菌, 避免或减少青枯菌PCR检测的假阳性和假阴性。  相似文献   

19.
Salmon eggs are common in Japanese sushi and other seafood products; however, certain fish eggs are used as counterfeit salmon eggs which are found in foods and processed products. This study develops a simple, rapid, and cost-effective method for DNA extraction, filtration (FT) and dilution (DL) protocols from a single salmon egg with good DNA quality for real-time PCR amplification. The DNA amount, DNA quality, and real-time PCR performance for different dilutions and different lengths of PCR amplicons were evaluated and compared with the common Qiagen tissue kit (QTK) and Chelex-100-based (CX) protocols. The extracted DNA from a single salmon egg using the FT or DL protocol can be applied in phylogenic research, food authentication and post-marketing monitoring of genetically modified (GM) food products.  相似文献   

20.
Mycoplasma contamination of biological materials remains a major problem. Most contaminations are caused by the use of Mycoplasma-contaminated cell lines. We adapted a Mycoplasma group-specific PCR to detect Mycoplasma contamination in cell lines and demonstrate its use in monitoring decontamination procedures with Mycoplasma-contaminated suspensions of Chlamydia spp. Three different methods were investigated: the use of Mycoplasma-specific antiserum in cell culture, physical separation by the combined use of enzymatic treatment and differential centrifugation, and the use of detergents. With these methods only incubation with Triton X-100 resulted in decontamination of Mycoplasma-contaminated suspensions of several laboratory strains of Chlamydia pneumoniae, C. pecorum, and C. trachomatis. Only one C. pneumoniae strain, UZG-1, was sensitive to Triton X-100 treatment. Since 39 of 40 throat swabs from patients with symptoms of an upper respiratory tract infection had positive reactions in the Mycoplasma group-specific PCR, this procedure could also have clinical significance in attempts to propagate C. pneumoniae strains from clinical specimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号