首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.

Background

Swallowing accelerometry has been suggested as a potential non-invasive tool for bedside dysphagia screening. Various vibratory signal features and complementary measurement modalities have been put forth in the literature for the potential discrimination between safe and unsafe swallowing. To date, automatic classification of swallowing accelerometry has exclusively involved a single-axis of vibration although a second axis is known to contain additional information about the nature of the swallow. Furthermore, the only published attempt at automatic classification in adult patients has been based on a small sample of swallowing vibrations.

Methods

In this paper, a large corpus of dual-axis accelerometric signals were collected from 30 older adults (aged 65.47 ± 13.4 years, 15 male) referred to videofluoroscopic examination on the suspicion of dysphagia. We invoked a reputation-based classifier combination to automatically categorize the dual-axis accelerometric signals into safe and unsafe swallows, as labeled via videofluoroscopic review. From these participants, a total of 224 swallowing samples were obtained, 164 of which were labeled as unsafe swallows (swallows where the bolus entered the airway) and 60 as safe swallows. Three separate support vector machine (SVM) classifiers and eight different features were selected for classification.

Results

With selected time, frequency and information theoretic features, the reputation-based algorithm distinguished between safe and unsafe swallowing with promising accuracy (80.48 ± 5.0%), high sensitivity (97.1 ± 2%) and modest specificity (64 ± 8.8%). Interpretation of the most discriminatory features revealed that in general, unsafe swallows had lower mean vibration amplitude and faster autocorrelation decay, suggestive of decreased hyoid excursion and compromised coordination, respectively. Further, owing to its performance-based weighting of component classifiers, the static reputation-based algorithm outperformed the democratic majority voting algorithm on this clinical data set.

Conclusion

Given its computational efficiency and high sensitivity, reputation-based classification of dual-axis accelerometry ought to be considered in future developments of a point-of-care swallow assessment where clinical informatics are desired.  相似文献   

2.

Background

Previous studies on the relation between lifestyle and the metabolic syndrome lack one or several aspects of the physical activity pattern in the analyses or cardiorespiratory fitness. Likewise, both uni- and triaxial accelerometry have been used, though, the predictive validity of these two modes has not been compared.

Objectives

The aims of the present study were firstly to investigate the independent relation between cardiorespiratory fitness and physical activity pattern to the metabolic syndrome (MetS) and secondly to examine the predictive validity of uni- and triaxial accelerometry, respectively.

Methods

Data was extracted from the SCAPIS pilot study (n=930, mean age 57.7 yrs). Physical activity pattern was assessed by accelerometry. Cardiorespiratory fitness was estimated using cycle ergometry. MetS was defined per the Adult Treatment Panel III from the National Cholesterol Education Program definition.

Results

Time spent sedentary (OR: 2.38, 95% CI: 1.54-4.24 for T3 vs T1), in light intensity (OR: 0.50, 95% CI: 0.28-0.90) and in moderate-to-vigorous activity (OR: 0.33, 95% CI: 0.18-0.61), as well as cardiorespiratory fitness (OR: 0.24, 95% CI:0.12-0.48), were all independently related to the prevalence of MetS after adjustment for potential confounders, fitness and/or the other aspects of the physical activity pattern. In addition, we found that triaxial analyses were more discriminant, with ORs farther away from the reference group and additional significant ORs.

Conclusion

The finding that several aspects of the physical activity pattern reveal independent relations to the MetS makes new possible targets for behaviour change of interest, focusing on both exercise and everyday life. When assessing the risk status of a patient, it is advised that triaxial accelerometry is used.  相似文献   

3.

Background

Swallowing is a continuous process with substantive interdependencies among different muscles, and it plays a significant role in our daily life. The aim of this study was to propose a novel technique based on high-density surface electromyography (HD sEMG) for the evaluation of normal swallowing functions.

Methods

A total of 96 electrodes were placed on the front neck to acquire myoelectric signals from 12 healthy subjects while they were performing different swallowing tasks. HD sEMG energy maps were constructed based on the root mean square values to visualize muscular activities during swallowing. The effects of different volumes, viscosities, and head postures on the normal swallowing process were systemically investigated by using the energy maps.

Results

The results showed that the HD sEMG energy maps could provide detailed spatial and temporal properties of the muscle electrical activity, and visualize the muscle contractions that closely related to the swallowing function. The energy maps also showed that the swallowing time and effort was also explicitly affected by the volume and viscosity of the bolus. The concentration of the muscular activities shifted to the opposite side when the subjects turned their head to either side.

Conclusions

The proposed method could provide an alternative method to physiologically evaluate the dynamic characteristics of normal swallowing and had the advantage of providing a full picture of how different muscle activities cooperate in time and location. The findings from this study suggested that the HD sEMG technique might be a useful tool for fast screening and objective assessment of swallowing disorders or dysphagia.
  相似文献   

4.

Background  

A common but debated technique in the management of swallowing difficulties is the chin tuck swallow, where the neck is flexed forward prior to swallowing. Natural variations in chin tuck angles across individuals may contribute to the differential effectiveness of the technique.  相似文献   

5.

Background  

Various functional resonance imaging, magnetoencephalographic and lesion studies suggest the involvement of the insular cortex in the control of swallowing. However, the exact location of insular activation during swallowing and its functional significance remain unclear.  相似文献   

6.

Background  

Early feeding via a nasogastric tube (NGT) is recommended as safe way of supplying nutrition in patients with acute dysphagic stroke. However, preliminary evidence suggests that NGTs themselves may interfere with swallowing physiology. In the present study we therefore investigated the impact of NGTs on swallowing function in acute stroke patients.  相似文献   

7.

Background

Respiratory involvement in neuromuscular disorders may contribute to impaired breathing-swallowing interactions, swallowing disorders and malnutrition. We investigated whether the use of non-invasive ventilation (NIV) controlled by the patient could improve swallowing performances in a population of neuromuscular patients requiring daytime NIV.

Methods

Ten neuromuscular patients with severe respiratory failure requiring extensive NIV use were studied while swallowing without and with NIV (while ventilated with a modified ventilator allowing the patient to withhold ventilation as desired). Breathing-swallowing interactions were investigated by chin electromyography, cervical piezoelectric sensor, nasal flow recording and inductive plethysmography. Two water-bolus sizes (5 and 10ml) and a textured yogurt bolus were tested in a random order.

Results

NIV use significantly improved swallowing fragmentation (defined as the number of respiratory interruption of the swallowing of a single bolus) (p = 0.003) and breathing-swallowing synchronization (with a significant increase of swallows followed by an expiration) (p <0.0001). Patient exhibited piecemeal swallowing which was not influenced by NIV use (p = 0.07). NIV use also significantly reduced dyspnea during swallowing (p = 0.04) while preserving swallowing comfort, regardless of bolus type.

Conclusion

The use of patient controlled NIV improves swallowing parameters in patients with severe neuromuscular respiratory failure requiring daytime NIV, without impairing swallowing comfort.

Trial Registration

ClinicalTrials.gov NCT01519388  相似文献   

8.

Background

Ecological validity implicates in how far clinical assessments refer to real life. Short clinical gait tests up to ten meters and 2- or 6-Minutes Walking Tests (2MWT/6MWT) are used as performance-based outcomes in Multiple Sclerosis (MS) studies and considered as moderately associated with real life mobility.

Objective

To investigate the ecological validity of 10 Meter Walking Test (10mWT), 2MWT and 6MWT.

Methods

Persons with MS performed 10mWT, 6MWT including 2MWT and 7 recorded days by accelerometry. Ecological validity was assumed if walking tests represented a typical walking sequence in real-life and correlations with accelerometry parameters were strong.

Results

In this cohort (n=28, medians: age=45, EDSS=3.2, disease duration=9 years), uninterrupted walking of 2 or 6 minutes occurred not frequent in real life (2.61 and 0.35 sequences/day). 10mWT correlated only with slow walking speed quantiles in real life. 2MWT and 6MWT correlated moderately with most real life walking parameters.

Conclusion

Clinical gait tests over a few meters have a poor ecological validity while validity is moderate for 2MWT and 6MWT. Mobile accelerometry offers the opportunity to control and improve the ecological validity of MS mobility outcomes.  相似文献   

9.
Eston, Roger G., Ann V. Rowlands, and David K. Ingledew.Validity of heart rate, pedometry, and accelerometry forpredicting the energy cost of children's activities.J. Appl. Physiol. 84(1): 362-371, 1998.Heart rate telemetry is frequently used to estimate dailyactivity in children and to validate other methods. This study comparedthe accuracy of heart rate monitoring, pedometry, triaxialaccelerometry, and uniaxial accelerometry for estimating oxygenconsumption during typical children's activities. Thirty Welshchildren (mean age 9.2 ± 0.8 yr) walked (4 and 6 km/h) and ran (8 and 10 km/h) on a treadmill, played catch, played hopscotch, and satand crayoned. Heart rate, body accelerations in three axes, pedometrycounts, and oxygen uptake were measured continuously during each 4-minactivity. Oxygen uptake was expressed as a ratio of body mass raised tothe power of 0.75 [scaled oxygen uptake (sO2)]. All measurescorrelated significantly (P < 0.001)with sO2. Amultiple-regression equation that included triaxial accelerometry counts and heart rate predictedsO2 better than any measure alone (R2 = 0.85, standard error of the estimate = 9.7 ml · kg0.75 · min1).The best of the single measures was triaxial accelerometry (R2 = 0.83, standard error of the estimate = 10.3 ml · kg0.75 · min1).It is concluded that a triaxial accelerometer provides the bestassessment of activity. Pedometry offers potential for large populationstudies.

  相似文献   

10.
11.

Background  

Aging has been shown to slow reflexes and increase reaction time to varied stimuli. However, the effect of Type II diabetes on these same reaction times has not been reported. Diabetes affects peripheral nerves in the somatosensory and auditory system, slows psychomotor responses, and has cognitive effects on those individuals without proper metabolic control, all of which may affect reaction times. The additional slowing of reaction times may affect every-day tasks such as balance, increasing the probability of a slip or fall.  相似文献   

12.

Background

Aiming for autonomous living for the people after a stroke is the challenge these days especially for swallowing disorders or dysphagia. The most common cause of dysphagia is stroke. In France, stroke occurs every 4 minutes, which implies 13000 hospitalizations per year. Currently, continuous medical home monitoring of patients is not available. The patient must be hospitalized or visit the medical community for possible follow-up. It is in this context that E-SwallHome (Swallowing & Breathing: Modelling and e-Health at Home) project proposes to develop tools, from hospital care until the patient returns home, which are able to monitor in real time the process of swallowing.

Method

This paper presents a relevant health problem affecting patient recovering from stroke. We propose a frequency acoustical analysis for automatic detection of swallowing process and a non-invasive acoustic based method to differentiate between swallowing sounds and other sounds in normal ambient environment during food intake.

Result

The proposal algorithm for events detection gives a global rate of good detection of 87.31%. Classification of sounds of swallowing and other sounds based on Gaussian Mixture Models (GMM), using the leave-one-out approach according to the small amount of data in our database, gives a good recognition rate of swallowing sounds of 84.57%.

Conclusion

The proposal method has great potential to assist in the clinical evaluation using only swallowing sounds, which is a non-invasive technic for swallowing studies.  相似文献   

13.

Background

Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation.

Methods

Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time.

Findings

Several physical changes appeared in the food bolus as it was formed during mastication: (1) in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2) by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3) median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4) except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5) physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication.

Conclusions

Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of swallowing, since they appeared in boluses prepared in various mastication strategies by different subjects.  相似文献   

14.

Background  

Botulism is a rare disease caused by intoxication leading to muscle weakness and rapidly progressive dysphagia. With adequate therapy signs of recovery can be observed within several days. In the last few years, brain imaging studies carried out in healthy subjects showed activation of the sensorimotor cortex and the insula during volitional swallowing. However, little is known about cortical changes and compensation mechanisms accompanying swallowing pathology.  相似文献   

15.

Background

Physical inactivity is responsible for 5.3 million deaths annually worldwide. To measure physical activity energy expenditure, the doubly labeled water (DLW) method is the gold standard. However, questionnaires and accelerometry are more widely used. We compared physical activity measured by accelerometer and questionnaire against total (TEE) and physical activity energy expenditure (PAEE) estimated by DLW.

Methods

TEE, PAEE (TEE minus resting energy expenditure) and body composition were measured using the DLW technique in 25 adolescents (16 girls) aged 13 years living in Pelotas, Brazil. Physical activity was assessed using the Actigraph accelerometer and by self-report. Physical activity data from accelerometry and self-report were tested against energy expenditure data derived from the DLW method. Further, tests were done to assess the ability of moderate-to-vigorous intensity physical activity (MVPA) to predict variability in TEE and to what extent adjustment for fat and fat-free mass predicted the variability in TEE.

Results

TEE varied from 1,265 to 4,143 kcal/day. It was positively correlated with physical activity (counts) estimated by accelerometry (rho  = 0.57; p = 0.003) and with minutes per week of physical activity by questionnaire (rho  = 0.41; p = 0.04). An increase of 10 minutes per day in moderate-to-vigorous intensity physical activity (MVPA) relates to an increase in TEE of 141 kcal/day. PAEE was positively correlated with accelerometry (rho  = 0.64; p = 0.007), but not with minutes per week of physical activity estimated by questionnaire (rho  = 0.30; p = 0.15). Physical activity by accelerometry explained 31% of the vssariability in TEE. By incorporating fat and fat-free mass in the model, we were able to explain 58% of the variability in TEE.

Conclusion

Objectively measured physical activity significantly contributes to the explained variance in both TEE and PAEE in Brazilian youth. Independently, body composition also explains variance in TEE, and should ideally be taken into account when using accelerometry to predict energy expenditure values.  相似文献   

16.

Background  

Feature selection is a pattern recognition approach to choose important variables according to some criteria in order to distinguish or explain certain phenomena (i.e., for dimensionality reduction). There are many genomic and proteomic applications that rely on feature selection to answer questions such as selecting signature genes which are informative about some biological state, e.g., normal tissues and several types of cancer; or inferring a prediction network among elements such as genes, proteins and external stimuli. In these applications, a recurrent problem is the lack of samples to perform an adequate estimate of the joint probabilities between element states. A myriad of feature selection algorithms and criterion functions have been proposed, although it is difficult to point the best solution for each application.  相似文献   

17.

Background  

The traditional two-point discrimination (TPD) test, a widely used tactile spatial acuity measure, has been criticized as being imprecise because it is based on subjective criteria and involves a number of non-spatial cues. The results of a recent study showed that as two stimuli were delivered simultaneously, vibrotactile amplitude discrimination became worse when the two stimuli were positioned relatively close together and was significantly degraded when the probes were within a subject's two-point limen. The impairment of amplitude discrimination with decreasing inter-probe distance suggested that the metric of amplitude discrimination could possibly provide a means of objective and quantitative measurement of spatial discrimination capacity.  相似文献   

18.

Background

Paired associative stimulation (PAS) consisting of repeated application of transcranial magnetic stimulation (TMS) pulses and contingent exteroceptive stimuli has been shown to induce neuroplastic effects in the motor and somatosensory system. The objective was to investigate whether the auditory system can be modulated by PAS.

Methods

Acoustic stimuli (4 kHz) were paired with TMS of the auditory cortex with intervals of either 45 ms (PAS(45 ms)) or 10 ms (PAS(10 ms)). Two-hundred paired stimuli were applied at 0.1 Hz and effects were compared with low frequency repetitive TMS (rTMS) at 0.1 Hz (200 stimuli) and 1 Hz (1000 stimuli) in eleven healthy students. Auditory cortex excitability was measured before and after the interventions by long latency auditory evoked potentials (AEPs) for the tone (4 kHz) used in the pairing, and a control tone (1 kHz) in a within subjects design.

Results

Amplitudes of the N1-P2 complex were reduced for the 4 kHz tone after both PAS(45 ms) and PAS(10 ms), but not after the 0.1 Hz and 1 Hz rTMS protocols with more pronounced effects for PAS(45 ms). Similar, but less pronounced effects were observed for the 1 kHz control tone.

Conclusion

These findings indicate that paired associative stimulation may induce tonotopically specific and also tone unspecific human auditory cortex plasticity.  相似文献   

19.

Background  

In this study, investigating the effects of mobile phone radiation on test animals, eleven pigs were anaesthetised to the level where burst-suppression pattern appears in the electroencephalogram (EEG). At this level of anaesthesia both human subjects and animals show high sensitivity to external stimuli which produce EEG bursts during suppression. The burst-suppression phenomenon represents a nonlinear control system, where low-amplitude EEG abruptly switches to very high amplitude bursts. This switching can be triggered by very minor stimuli and the phenomenon has been described as hypersensitivity. To test if also radio frequency (RF) stimulation can trigger this nonlinear control, the animals were exposed to pulse modulated signal of a GSM mobile phone at 890 MHz. In the first phase of the experiment electromagnetic field (EMF) stimulation was randomly switched on and off and the relation between EEG bursts and EMF stimulation onsets and endpoints were studied. In the second phase a continuous RF stimulation at 31 W/kg was applied for 10 minutes. The ECG, the EEG, and the subcutaneous temperature were recorded.  相似文献   

20.

Background

Pain is difficult to assess due to the subjective nature of self-reporting. The lack of objective measures of pain has hampered the development of new treatments as well as the evaluation of current ones. Functional MRI studies of pain have begun to delineate potential brain response signatures that could be used as objective read-outs of pain. Using Diffuse Optical Tomography (DOT), we have shown in the past a distinct DOT signal over the somatosensory cortex to a noxious heat stimulus that could be distinguished from the signal elicited by innocuous mechanical stimuli. Here we further our findings by studying the response to thermal innocuous and noxious stimuli.

Methodology/Principal Findings

Innocuous and noxious thermal stimuli were applied to the skin of the face of the first division (ophthalmic) of the trigeminal nerve in healthy volunteers (N = 6). Stimuli temperatures were adjusted for each subject to evoke warm (equivalent to a 3/10) and painful hot (7/10) sensations in a verbal rating scale (0/10 = no/max pain). A set of 26 stimuli (5 sec each) was applied for each temperature with inter-stimulus intervals varied between 8 and 15 sec using a Peltier thermode. A DOT system was used to capture cortical responses on both sides of the head over the primary somatosensory cortical region (S1). For the innocuous stimuli, group results indicated mainly activation on the contralateral side with a weak ipsilateral response. For the noxious stimuli, bilateral activation was observed with comparable amplitudes on both sides. Furthermore, noxious stimuli produced a temporal biphasic response while innocuous stimuli produced a monophasic response.

Conclusions/Significance

These results are in accordance with fMRI and our other DOT studies of innocuous mechanical and noxious heat stimuli. The data indicate the differentiation of DOT cortical responses for pain vs. innocuous stimuli that may be useful in assessing objectively acute pain.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号