首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Capillary zone electrophoresis was employed for the determination of midecamycin using an end-column amperometric detection with a carbon fiber micro-disk bundle electrode at a constant potential of +1.15 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 1.00x10(-3) mol l(-1) Na(2)HPO(4)-3.49x10(-4) mol l(-1) NaOH (pH 11.4) for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The limit of detection is 5.0x10(-7) mol l(-1) or 0.41 fmol (S/N=3). The linear range of the calibration curve is 1.00x10(-6)-1.00x10(-3) mol l(-1). The relative standard deviation is 1.4% for the migration time and 4.9% for the electrophoretic peak current. The method could be applied to the determination of midecamycin in human urine. In this case, a separation voltage of 14 kV was used.  相似文献   

2.
Capillary zone electrophoresis was employed for the determination of lactate using end-column amperometric detection at a carbon fiber bundle microdisk electrode. The optimum conditions of separation and detection are 3.6 x 10(-3) mol/l Na(2)HPO(4)-1.4 x 10(-3) mol/l NaH(2)PO (pH 7.2) for the buffer solution, 18 kV for the separation voltage and 1.60 V versus the saturated calomel electrode for the detection potential. The limit of detection is 7.6 x 10(-7) mol/l or 1.7 fmol (S/N=3) and the linear range is 1.7 x 10(-6)-8.2 x 10(-4) mol/l for the injection voltage of 6 kV and injection time of 5 s. The RSD is 1.8% for the migration time and 3.3% for the electrophoretic peak current. The method was applied to the determination of lactate in human saliva. The recovery of the method is between 95 and 109%.  相似文献   

3.
Capillary electrophoresis (CE) was employed to analyze lactate dehydrogenase (LDH) in human erythrocytes using an amperometric detector with a carbon fiber micro-disk bundle electrode. LDH activity was measured by determining the amount of NADH generated by LDH through a enzyme-catalyzed reaction between NAD(+) and lithium lactate. The factors influencing the enzyme-catalyzed reaction, separation and detection were examined and optimized. The following conditions were suitable for the determination of LDH: running buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 7.5); separation voltage, 20.0 kV; detection potential, 1.00 V (versus saturated calomel electrode (SCE)). The conditions of enzyme-catalyzed reaction were: reaction buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 9.3); substrates, 5.0 x 10(-2)mol/l lithium lactate and 5.0 x 10(-3)mol/l NAD(+); reaction time, 10 min. The concentration limit of detection (LOD) of the method was 0.017 U/ml at a signal-to-noise (S/N) ratio of 3, which corresponded to 1.10 x 10(-10)mol/l, and the mass LOD was 2 x 10(-20)mol. The linear dynamic range was 0.039-4.65 U/ml for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the electrophoretic peak area. The method was applied to determine LDH in human erythrocytes. The recovery of the method was between 98 and 101%.  相似文献   

4.
A method for the direct determination of ascorbic acid (AA) in individual rat hepatocyte based on capillary electrophoresis (CE) coupled with electrochemical detection (ECD) using a new kind of homemade carbon fiber micro-disk bundle electrode has been described. Individual rat hepatocytes were injected into a fused-silica capillary with an inner diameter of 25 microm, and lysed by 0.1% sodium dodecylsulfate (SDS) as cell lysis solution. The following conditions were suitable for the determination of AA: running buffer, 1.83 x 10(-2) mol/l Na2HPO4-1.70 x 10(-3) mol/l NaH2PO4 (pH 7.8); separation voltage, 20.0 kV; detection potential, 0.80 V (vs. saturated calomel electrode (SCE)). The concentration limit of detection (LOD) of the method was 1.7 x 10(-6) mol/l at a signal-to-noise (S/N) ratio of 3, and the mass LOD was 3.0 fmol. The linear dynamic range was from 5.0 x 10(-6) to 5.0 x 10(-4) mol/l with a correlation coefficient of 0.9962 for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the peak current. This method was successfully applied to AA determination in rat hepatocyte. The recovery was between 91% and 97%, and the amount of AA in single rat hepatocyte ranged from 28 to 63 fmol.  相似文献   

5.
Capillary zone electrophoresis was employed for the measurement of chloramphenicol using end-column amperometric detection with a carbon fiber micro-disk array electrode, at a constant potential of −1.00 V vs. saturated calomel electrode. The effect of oxygen in the buffer has been investigated. It is found that when the area of the carbon fiber electrode is smaller than 1.1 mm2, the interference of oxygen can be overcome. In this procedure deoxygenation is not necessary. The effect of pH, the concentration of the buffer and the high separation voltage across the capillary on the migration time, electrophoretic peak current and separation efficiency has been studied. The optimum conditions of separation and detection are 8.4×10−4 mol/l HOAc–3.2×10−3 mol/l NaOAc for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The calibration plot was found to be linear in the range 5×10−6 to 1×10−3 mol/l and the limit of detection is 9.1×10−7 mol/l or 1.4 fmol (S/N=2). The relative standard deviation is 1.1% for the migration time and 2.3% for the electrophoretic peak current. The method was applied to the determination of chloramphenicol in human serum.  相似文献   

6.
The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N=3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.  相似文献   

7.
A novel determination method for josamycin (JOS) based on capillary electrophoresis-electrochemiluminescence detection has been described. In this study, platinum disk electrode (300 microm in diameter) was used as a working electrode and the conditions affecting separation and detection were investigated in detail. Under optimal condition: 40 cm separation capillary (75 microm i.d.); 1.25 V applied potential on the Pt disc of the ECL detector cell; 5 mM Ru(bpy)3(2+) and 50mM phosphate buffer (pH 7.5) in the detection cell; 12 kV separation voltage; 8s injection time; 10 kV injection voltage and 15 mM running buffer (pH 7.5), calibration curve was linear over the range from 10 ng/mL to 5.0 microg/mL with a detection limit of 3.1 ng/mL at a signal-to-noise ratio of 3. The method can be successfully applied for the determination of josamycin in rat plasma in 6 min and the extraction recoveries with spiked plasma samples were over 92%.  相似文献   

8.
The monitoring of uric acid (UA) and p-aminohippuric acid (PAH) levels in biological samples is routinely carried out in clinical laboratories as an indication of renal disease. With the aim of investigation of the correlation between the trace amounts of UA and PAH in human saliva or urine and renal diseases, we carried out the determination of UA and PAH in human saliva and urine by using capillary electrophoresis with electrochemical detection (CE-ED) in this work. Under the optimum conditions, UA, PAH and three coexisting analytes could be well separated within 21 min at the separation voltage of 14 kV in 80 mmol/L borax running buffer (pH 9.2). Good linear relationship was established between peak current and concentration of analytes over two orders of magnitude with detection limits (S/N = 3) ranged from 5.01 x 10(-7) to 2.00 x 10(-6) mol/L for all analytes. The result shows that this proposed method could be successfully applied for the study on the correlation between the levels of UA and PAH in human saliva and urine and renal diseases, and provide an alternative and convenient method for the fast diagnosis of renal disease.  相似文献   

9.
Yu Q  Zhao S  Ye F  Li S 《Analytical biochemistry》2007,369(2):187-191
A new analytical method based on capillary electrophoresis (CE) separation and optical fiber light-emitting diode (LED)-induced fluorescence detection has been developed for the determination of octopamine. Naphthalene-2,3-dicarboxaldehyde (NDA) was used for precolumn derivatization of octopamine. The separation and determination of the derivative was performed using a laboratory-built CE system with an optical fiber LED-induced fluorescence detector. Optimal separation was obtained at 20 kV using a background electrolyte solution consisting of 25 mM sodium borate (pH 9.2). High sensitivity detection was achieved by the optical fiber LED-induced fluorescence detection using a purple LED as the excitation source. The limit of detection (signal/noise=3) for octopamine was 5.0 x 10(-9)M. A calibration curve ranging from 1.0 x 10(-8) to 5.0 x 10(-7)M was shown to be linear. Using this method, the levels of octopamine in human plasma from healthy donors were determined.  相似文献   

10.
A simple electrogenerated chemiluminescence (ECL) analysis method for the determination of norfloxacin (NFLX) is reported. It is based on ECL produced by Na(2)SO(3), which is sensitized by the Tb-NFLX complex. The relative ECL intensity of the Tb(3+)-NFLX-Na(2)SO(3) system is proportional to the amount of NFLX. The optimized experimental conditions were investigated. The linear range and detection limit for NFLX were 1.0 x 10(-10)-8.0 x 10(-7) mol/L and 2.8 x 10(-11) mol/L, respectively. This method was successfully applied to the determination of NFLX in a capsule. NFLX in urine can be directly detected without pretreatment or separation.  相似文献   

11.
The reaction of soluble manganese (IV) with sulphite in acidic condition was found to elicit weak chemiluminescence (CL). The CL signal was remarkably enhanced in the presence of three fluoroquinolones, viz. norfloxacin, ofloxacin and ciprofloxacin. Based on these observations, a new flow-injection CL method was developed for the determination of these fluoroquinolones. The method allows determination in the range 5.0 x 10(-8)-1.0 x 10(-6) mol/L for norfloxacin, 1.0 x 10(-7)-8.0 x 10(-6) mol/L for ofloxacin and 1.0 x 10(-7)-3.0 x 10(-5) mol/L for ciprofloxacin, with detection limits of 3 x 10(-8) mol/L, 5 x 10(-8) mol/L and 3 x 10(-8) mol/L, respectively. The method was applied to the determination of fluoroquinolones in pharmaceutical preparations.  相似文献   

12.
A stable electroactive thin film of poly(caffeic acid) has been deposited on the surface of a glassy carbon electrode by potentiostatic technique in an aqueous solution containing caffeic acid. Poly(caffeic acid) was used as a modified electrode for the detection of ascorbic acid (AA), epinephrine (EP), uric acid (UA) and their mixture by cyclic voltammetry. This modified electrode exhibits potent and persistent electron-mediating behavior followed by well-separated oxidation peaks towards AA, EP and UA with activation overpotential. For the ternary mixture containing AA, EP and UA, the three compounds can well separate from each other at the scan rate of 20 mVs(-1) with a potential difference of 156, 132 and 288 mV between AA and EP, EP and UA and AA and UA, respectively, which was large enough to determine AA, EP and UA individually and simultaneously. The catalytic peak current obtained, was linearly dependent on the AA, EP and UA concentrations in the range of 2.0 x 10(-5) to 1.0 x 10(-3) mol l(-1), 2.0 x 10(-6) to 8.0 x 10(-5) mol l(-1) and 5.0 x 10(-6) to 3.0 x 10(-4) mol l(-1), and the detection limits for AA, EP and UA were 7.0 x 10(-6), 2.0 x 10(-7) and 6.0 x 10(-7) mol l(-1), respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of EP in practical injection samples and that of EP, UA and AA simultaneously with satisfactory results.  相似文献   

13.
A capillary zone electrophoretic (CZE) method was investigated for the determination of Gleevec and its main metabolite (N-demethylated piperazine derivative) in human urine using a fused-silica capillary (75 microm I.D.x60 cm total length, 10 cm effective length). The separation was performed with an hydrodynamic injection time of 10 s (0.5 p.s.i.) a voltage of -25 kV, a capillary temperature of 25 degrees C and a 100 mM phosphoric acid adjusted to pH 2 with the addition of triethanolamine. Under these conditions, the analysis takes about 5 min. A linear response over the 0.4-30.0 mg l(-1) concentration range was investigated for two compounds. A dilution of the sample was the only step necessary before the electrophoresis analysis. Detection limits of 0.1 mg l(-1) for Gleevec and its metabolite (S/N=3) were obtained. The developed method is easy, rapid and sensitive and has been applied to determine Gleevec and its main metabolite in clinical urine samples.  相似文献   

14.
The fabrication and application of a novel electrochemical detection (ED) method with the functionalized multi-wall carbon nanotubes (MWNTs) chemically modified electrode (CME) for liquid chromatography (LC) were described. The electrochemical behaviors of dopamine (DA) and other monoamine neurotransmitters at the CME were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The results indicated that the CME exhibited efficient electrocatalytic effects on the current responses of monoamine neurotransmitters and their metabolites with high sensitivity, high stability and long-life activity. In LC-ED, DA, norepinephrine (NE), 3-methoxy-4-hydroxyphenylglycol (MHPG), 3,4-dihydroxyphenylacetic acid (DOPAC), 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA) had good and stable current responses at the CME. The linear ranges of seven analytes were over four orders of magnitude and the detection limits were 2.5 x 10(-10) mol/l for DA, 2.5 x 10(-10) mol/l for NE, 5.0 x 10(-10) mol/l for MHPG, 3.0 x 10(-10) mol/l for DOPAC, 3.5 x 10(-10) mol/l for 5-HT, 6.0 x 10(-10) mol/l for 5-HIAA, 1.25 x 10(-9) mol/l for HVA. The application of this method coupled with microdialysis sampling for the determination of monoamine neurotransmitters and their metabolites in Parkinsonian patients' cerebrospinal fluid was satisfactory.  相似文献   

15.
A new flow injection chemiluminescence (CL) method has been developed for the determination of bisphenol A (BPA), based on the inhibitory effect of BPA on the chemiluminescence reaction between luminol and potassium hexacyanoferrate. Under optimum conditions, the decrease in CL emission intensity was linear with BPA concentration in the range 8.0 x 10(-7)-1.2 x 10(-5) mol/L, and the detection limit was 3.1 x 10(-7) mol/L. The relative standard deviation (RSD) of 11 replicate measurements was 2.6% for 2.0 x 10(-6) mol/L BPA (n = 11). The sampling frequency was calculated to be ca. 120/h. This method has been successfully used to determine the content of BPA in aqueous solution of polycarbonate materials. A brief discussion on the possible chemiluminescence reaction mechanism is presented.  相似文献   

16.
The prolonged effect of thyroliberin in ULD after single intramuscular injection on contractility of lymphatic vessels directly was investigated. The controlled group of animals received injection of 0.2 ml of physiological solution. The experimental group was injected by 0.2 ml of thyroliberin in concentrations of 10(-10) or 10(-16) mol/l (1 x 10(-4) and 1 x 10(-10) micrograms/kg of the body weight respectively). During the experiment the animals were grouped in the following way: 1) directly after the injection; 2) 3 hours later; 3) on the 1st day and then every day during 2 weeks. Lymphatic vessels reactivity of the experimental animals as well as controlled was studied by application of thyroliberin and noradrenalin (in concentrations of 1 x 10(-16) and 1 x 10(-6) mol/l respectively) directly on mesentery lymphatic vessels. The lymphatic vessels reaction in control group of animals on the noradrenalin and thyroliberin was the same during the period of observation. Thyroliberin stimulated contractility at concentration of 1 x 10(-16) mol/l. The reaction of experimental group was dramatically decreased to 10(-4) mol/l on the 1st and the 3rd day (in the case i.m. injected concentration 1 x 10(-10) mol/l) and to 10(-10) mol/l (in the case of i.m. injected concentration 10(-16) mol/l). The lymphatic vessels reactivity to exogenous thyroliberin gradually established at the 6-7th days till 12th day from the moment of thyroliberin injection. The mechanisms of the action of thyroliberin in ULD are discussed.  相似文献   

17.
Capillary electrophoresis (CE) with amperometric detection (AD) has been developed for the separation and determination of disaccharide glycoside rutin, gentistic acid, quercetin, and gallic acid in the leaves of Ricinus communis Linn. for the first time. The effects of the acidity and the concentration of the running buffer, separation voltage, injection time, and detection potential were investigated to acquire the optimum conditions for the determination of the four analytes. The detection electrode was a 300microm diameter carbon disc electrode at a detection potential of +0.90V (versus saturated calomel electrode (SCE)). The four analytes could be well separated within 10min in a 40cm length fused silica capillary at a separation voltage of 15kV in a 50mM borate buffer (pH 9.0). The relation between peak current and analyte concentration was linear over about 3 orders of magnitude with detection limits (S/N=3) ranging from 0.8 to 2.9microM for all the analytes. The proposed method has been successfully applied to monitor flavones and phenolic acids in the real plant samples with satisfactory assay results.  相似文献   

18.
A sensitive capillary electrophoresis–electrochemiluminescence (CE–ECL) assay with an ionic liquid (IL) was developed for the determination of arecoline in areca nut. The IL, 1‐butyl‐3‐methylimidazolium tetrafluoroborate (BMImBF4), was an effective additive improved not only the separation selectivity but also the detection sensitivity of the analyte. BMImBF4 in the separation electrolyte made the resistance of the separation buffer much lower than that of the sample solution, which resulted in an enhanced field amplified electrokinetic injection CE. ECL intensity of arecoline is about two times higher than that of the analyte with phosphate–IL buffer system. Resolution between arecoline and other unknown compounds in real samples was improved. Under the optimized conditions (ECL detection at 1.2 V, 16 kV separation voltage, 20 mmol/L phosphate with 10 mmol/L BMImBF4 buffer at pH 7.50, 5 mmol/L Ru(bpy)32+ and 50 mmol/L phosphate buffer in the detection reservoir), a detection limit of 5 × 10–9 mol/L for arecoline was obtained. Relative standard deviations of the ECL intensity and the migration time were 4.51% and 0.72% for arecoline. This method was successfully applied to determination of the amount of arecoline in areca nut within 450 s. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A capillary zone electrophoresis method with laser induced fluorescence detection for the chiral separation of highly fluorescent enantiomeric derivatives of d/l-Serine from 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-d/l-Serine) was developed and optimized. Enantiomeric separation of NBD-d/l-Serine was accomplished by using 40 mM hydroxypropyl-beta-cyclodextrin (HP-beta-CD) contained in 100 mM borate buffer, pH 10.0. A 70 cm (effective length of 50 cm) uncoated fused-silica capillary at a voltage of 15 kV was used for the separation. The optimized electrophoretic conditions were subsequently applied to the analysis of d-Serine in rat brain, and satisfactory analytical results with respect to accuracy were obtained. This assay showed acceptable precision, with linearity in the d-Serine concentration range of 0.2-20.0 microM. The limit of detection for d-Serine was 3.0 x 10(-7)M.  相似文献   

20.
Suqin Han  Erbao Liu  Hua Li 《Luminescence》2006,21(2):106-111
This paper reports an indirect flow-injection (FI) method for the determination of the tetracycline drugs (TCs), tetracycline (TC), chlortetracycline (CTC) and oxytetracycline (OTC), using copper(II) as a probe ion. The method was based on the inhibition caused by these TCs to the copper(II)-catalysed chemiluminescence (CL) reaction between luminol and H(2)O(2). The CL reaction was induced on-line and injection of the sample produced negative peaks as a result of the copper(II) complexation or displacement by the analytes. The height of the peaks was proportional to the drug concentration in the sample. The choice of the catalyst ion, the concentration of luminol, H(2)O(2) and copper(II) are discussed. The linear range was 3.6 x 10(-8)-1.0 x 10(-5), 1.1 x 10(-7)-1.0 x 10(-5) and 1.9 x 10(-7)-1.0 x 10(-5) mol/L for TC, CTC and OTC, respectively. The detection limit was 5.0 x 10(-9) mol/L for TC, 1.0 x 10(-8) mol/L for CTC and 2.0 x 10(-8) mol/L for OTC (3sigma), respectively. The method was applied to the determination of TCs in pharmaceutical preparations and human urine with recoveries in the range 95-105%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号