1.
Legionella pneumophila, a bacterium that replicates within aquatic amoebae and persists in the environment as a free-living microbe, is the causative agent of Legionnaires' disease. Among the many Legionella species described, L. pneumophila is associated with 90% of human disease, and within the 15 serogroups (Sg), L. pneumophila Sg1 causes more than 84% of Legionnaires' disease worldwide. Thus, rapid and specific identification of L. pneumophila Sg1 is of the utmost importance for evaluation of the contamination of collective water systems and the risk posed. Previously we had shown that about 20 kb of the 33-kb locus carrying the genes coding for the proteins involved in lipopolysaccharide biosynthesis (LPS gene cluster) by L. pneumophila was highly specific for Sg1 strains and that three genes (lpp0831, wzm, and wzt) may serve as genetic markers. Here we report the sequencing and comparative analyses of this specific region of the LPS gene cluster in L. pneumophila Sg6, -10, -12, -13, and -14. Indeed, the wzm and wzt genes were present only in the Sg1 LPS gene cluster, which showed a very specific gene content with respect to the other five serogroups investigated. Based on this observation, we designed primers and developed a classical and a real-time PCR method for the detection and simultaneous identification of L. pneumophila Sg1 in clinical and environmental isolates. Evaluation of the selected primers with 454 Legionella and 38 non-Legionella strains demonstrated 100% specificity. Sensitivity, specificity, and predictive values were further evaluated with 209 DNA extracts from water samples of hospital water supply systems and with 96 respiratory specimens. The results showed that the newly developed quantitative Sg1-specific PCR method is a highly specific and efficient tool for the surveillance and rapid detection of high-risk L. pneumophila Sg1 in water and clinical samples.  相似文献   

2.
Legionella pneumophila is the primary cause of the legionellosis diseases (90 %) (Yu et al. in J Infect Dis 186:127–128, 2002; Doleans et al. in J Clin Microbiol 42:458–460, 2004; Den Boer et al. in Clin Microbiol Infect 14:459–466, 2008). In this study, methodologies based on molecular biology were developed in order to provide a quick diagnosis of the bacterial presence in water samples of Spain. Multiplex real-time polymerase chain reaction assays were realized to target the 16S rRNA and macrophage infectivity potentiator (mip) genes of, respectively, Legionella spp. and L. pneumophila including in the design of an internal control. The results obtained by the culture and the gene amplification methods agreed in 94.44 % for the 16S rRNA gene, and a concordance of 66.67 % of the cases was obtained for the mip gene.  相似文献   

3.
AIMS: Legionella pneumophila is a contaminant of man-made water systems, including potable water, cooling towers, water systems of large buildings, etc. It is the most common causative agent of legionellosis, a respiratory infection, which may give rise to restricted outbreaks. To survey environmental water samples from hospitals and private habitations in Bologna, we developed a species-specific nested and a TaqMan real-time PCR for the detection of L. pneumophila. We compared the two assays and both to cultural isolation. METHODS AND RESULTS: The targeted gene was macrophage infectivity potentiator (mip), conserved in L. pneumophila, and divergent in other legionellae. One assay was based on a nested PCR and the other on a TaqMan real-time PCR protocol. Their sensitivities were 14 % or 5% higher than that of cultural isolation respectively. The detection limits were 1-2 genome equivalents per 50-microl reaction. Specificity was assessed using DNA from nine target and 20 nontarget organisms. CONCLUSIONS: When applied to water samples, both assays detected L. pneumophila at 80% or higher frequency. SIGNIFICANCE AND IMPACT OF THE STUDY: The species-specific molecular diagnosis of L. pneumophila by means of nested PCR does not require a specific instrumentation, exhibits a high sensitivity, and is advantageous over the cultural isolation and real-time PCR detection. It allows to quickly monitor water samples for the risk assessment of environmental contaminations.  相似文献   

4.
5.
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.  相似文献   

6.
Aims: This study was designed to evaluate the usefulness of quantification by real‐time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90‐431). Methods and Results: Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 105 GU l?1) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57–100% of the samples. Conclusions: These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real‐time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. Significance and Impact of the Study: This study shows the possibility of using real‐time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters.  相似文献   

7.
A comparative assessment of conventional culture and nucleic acid techniques in the detection of Legionella pneumophila in seeded tap water samples was performed, using bacterial concentrations ranging from 994 to 0·015 cfu ml−1. Different filtration and centrifugation protocols were evaluated. The results permitted the development of a tentative algorithm for the detection of legionellae in tap water. Samples should first be analysed using PCR methods. In the event of quantitative data and bacterial strains for epidemiologic typing being required, the same sample, or a greater volume of the sample, if positive with PCR, can be re-tested by filtration through polycarbonate membranes followed by plating a homogenate of the filter. If samples are found to be negative with PCR, they can be re-analysed in greater volumes by filtration through polycarbonate membranes followed by direct placing of the filter on culture media, to allow detection of very low numbers of bacteria. This protocol should be validated in the field before it can be routinely implemented.  相似文献   

8.
We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.  相似文献   

9.
Aims: To perform an international trial to derive alert and action levels for the use of quantitative PCR (qPCR) in the monitoring of Legionella to determine the effectiveness of control measures against legionellae. Methods and Results: Laboratories (7) participated from six countries. Legionellae were determined by culture and qPCR methods with comparable detection limits. Systems were monitored over ≥10 weeks. For cooling towers (232 samples), there was a significant difference between the log mean difference between qPCR (GU l?1) and culture (CFU l?1) for Legionella pneumophila (0·71) and for Legionella spp. (2·03). In hot and cold water (506 samples), the differences were less, 0·62 for Leg. pneumophila and 1·05 for Legionella spp. Results for individual systems depended on the nature of the system and its treatment. In cooling towers, Legionella spp. GU l?1 always exceeded CFU l?1, and usually Legionella spp. were detected by qPCR when absent by culture. The pattern of results by qPCR for Leg. pneumophila followed the culture trend. In hot and cold water, culture and qPCR gave similar results, particularly for Leg. pneumophila. There were some marked exceptions with temperatures ≥50°C, or in the presence of supplementary biocides. Action and alert levels for qPCR were derived that gave results comparable to the application of the European Guidelines based on culture. Algorithms are proposed for the use of qPCR for routine monitoring. Conclusions: Action and alert levels for qPCR can be adjusted to ensure public health is protected with the benefit that remedial actions can be validated earlier with only a small increase in the frequency of action being required. Significance and Impact of the Study: This study confirms it is possible to derive guidelines on the use of qPCR for monitoring the control of legionellae with consequent improvement to response and public health protection.  相似文献   

10.
A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.  相似文献   

11.
Ecology of Legionella pneumophila within water distribution systems   总被引:7,自引:0,他引:7  
The reservoir for hospital-acquired Legionnaires disease has been shown to be the potable water distribution system. We investigated the influence of the natural microbial population and sediment (scale and organic particulates) found in water systems as growth-promoting factors for Legionella pneumophila. Our in vitro experiments showed that: (i) water from hot-water storage tank readily supported the survival of L. pneumophila, (ii) the concentration of sediment was directly related to the survival of L. pneumophila, (iii) the presence of environmental bacteria improved the survival of L. pneumophila via nutritional symbiosis, (iv) the combination of sediment and environmental bacteria acted synergistically to improve the survival of L. pneumophila, and (v) the role of sediment in this synergistic effect was determined to be nutritional. Sediment was found to stimulate the growth of environmental microflora, which in turn stimulated the growth of L. pneumophila. These findings confirm the empiric observations of the predilection of L. pneumophila for growth in hot-water tanks and its localization to sediment. L. pneumophila occupies an ecological niche within the potable water system, with interrelationships between microflora, sediment, and temperature.  相似文献   

12.
This study describes the development and evaluation of a specific Legionella pneumophila Taqman duplex real-time PCR (qPCR) for fast and reliable quantification of this human pathogen in suspected man-made water systems. The qPCR assay was 100% specific for all L. pneumophila serogroups 1-15 with a sensitivity of 60 genome units/l and an amplification efficiency of 98%. Amplification inhibitors were detected via an exogenous internal positive control, which was amplified simultaneously with L. pneumophila DNA using its own primer and probe set. Mean recovery rates of the qPCR assay for tap water and cooling circuit water, spiked with a known number L. pneumophila bacteria, were 93.0% and 56.3%, respectively. Additionally, by using the Ultraclean Soil DNA isolation kit, we were able to remove amplification inhibitors ubiquitously present in cooling water. The practical value of our qPCR assay was evaluated through analysis of 30 water samples from showers, taps, eyewash stations, fire sprinklers and recirculation loops with qPCR and traditional culture. In conclusion, the described L. pneumophila Taqman duplex real-time assay proved to be specific, sensitive and reproducible. This makes it a promising method complementing the current time-consuming culture standard method.  相似文献   

13.
The presence of high levels of Legionella pneumophila in man-made aquatic systems correlates with the incidence of nosocomial Legionnaires' disease. This requires a rapid, reliable, and sensitive quantification of L. pneumophila concentrations in suspected water systems. In this research, a homologous competitor was developed and evaluated in a L. pneumophila competitive polymerase chain reaction (cPCR) to quantify this human pathogen in a quick, cost-effective, and reliable way. Accuracy of cPCR was evaluated by analyzing cooling tower and tap water samples spiked with known concentrations of L. pneumophila bacteria, in parallel with the standard culture method. Legionella pneumophila amounts detected and calculated from cPCR and culture correlated very well: r = 0.998, P = 0.002 for tap water and r = 0.990, P = 0.009 for cooling tower water. Nevertheless, for both kinds of water samples, mean numbers of L. pneumophila calculated from cPCR results were always higher than those obtained by culture. This study makes it clear that the rapid, sensitive, and cost-effective L. pneumophila cPCR is a promising alternative to the standard time-consuming culture method and expensive real-time PCR to enumerate L. pneumophila bacteria in environmental water samples.  相似文献   

14.
15.
Ecology of Legionella pneumophila within water distribution systems.   总被引:1,自引:10,他引:1       下载免费PDF全文
J E Stout  V L Yu    M G Best 《Applied microbiology》1985,49(1):221-228
The reservoir for hospital-acquired Legionnaires disease has been shown to be the potable water distribution system. We investigated the influence of the natural microbial population and sediment (scale and organic particulates) found in water systems as growth-promoting factors for Legionella pneumophila. Our in vitro experiments showed that: (i) water from hot-water storage tank readily supported the survival of L. pneumophila, (ii) the concentration of sediment was directly related to the survival of L. pneumophila, (iii) the presence of environmental bacteria improved the survival of L. pneumophila via nutritional symbiosis, (iv) the combination of sediment and environmental bacteria acted synergistically to improve the survival of L. pneumophila, and (v) the role of sediment in this synergistic effect was determined to be nutritional. Sediment was found to stimulate the growth of environmental microflora, which in turn stimulated the growth of L. pneumophila. These findings confirm the empiric observations of the predilection of L. pneumophila for growth in hot-water tanks and its localization to sediment. L. pneumophila occupies an ecological niche within the potable water system, with interrelationships between microflora, sediment, and temperature.  相似文献   

16.
Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs.  相似文献   

17.
Quantitative Legionella PCRs targeting the 16S rRNA gene (specific for the genus Legionella) and the mip gene (specific for the species Legionella pneumophila) were applied to a total of 223 hot water system samples (131 in one laboratory and 92 in another laboratory) and 37 cooling tower samples (all in the same laboratory). The PCR results were compared with those of conventional culture. 16S rRNA gene PCR results were nonquantifiable for 2.8% of cooling tower samples and up to 39.1% of hot water system samples, and this was highly predictive of Legionella CFU counts below 250/liter. PCR cutoff values for identifying hot water system samples containing >10(3) CFU/liter legionellae were determined separately in each laboratory. The cutoffs differed widely between the laboratories and had sensitivities from 87.7 to 92.9% and specificities from 77.3 to 96.5%. The best specificity was obtained with mip PCR. PCR cutoffs could not be determined for cooling tower samples, as the results were highly variable and often high for culture-negative samples. Thus, quantitative Legionella PCR appears to be applicable to samples from hot water systems, but the positivity cutoff has to be determined in each laboratory.  相似文献   

18.
Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs.  相似文献   

19.
Aim: To identify media and environmental conditions suitable for rapid mycelial growth and sporulation of Diplocarpon mali. Methods and Results: Liquid shake cultures were used to evaluate effects of media and environmental conditions on mycelial growth and conidial production of D. mali. Carrot sucrose broth (CSB), potato and carrot dextrose broth (PCDB) and potato and carrot sucrose broth (PCSB) were most favourable for rapid mycelial growth. PCDB, PCSB, PCB (potato and carrot broth) and carrot dextrose broth (CDB) were favourable for conidial production. All carbon sources tested and peptone favoured for mycelial growth. Carbon and nitrogen sources tested did not significantly stimulate conidial production. The optimum temperature for mycelial growth and conidial production was 25°C. No mycelial growth occurred at 5 or 30°C, but D. mali survived at these temperatures. Active mycelial growth occurred at pH 5–7, and pH 5–8 was favourable for sporulation. Conclusions: PCDB and PCSB incubated at 25°C for 14 day are recommended for mycelial growth and conidial production of D. mali. Significance and Impact of the Study: The information generated in this study will facilitate mycological and pathological research on D. mali and Marssonina leaf blotch of apple caused by D. mali.  相似文献   

20.
Aims: This study was designed to define the extent of water contamination by Legionella pneumophila of certain Italian hotels and to compare quantitative real‐time PCR with the conventional culture method. Methods and Results: Nineteen Italian hotels of different sizes were investigated. In each hotel three hot water samples (boiler, room showers, recycling) and one cold water sample (inlet) were collected. Physico‐chemical parameters were also analysed. Legionella pneumophila was detected in 42% and 74% of the hotels investigated by the culture method and by real‐time PCR, respectively. In 21% of samples analysed by the culture method, a concentration of >104 CFU l?1 was found, and Leg. pneumophila serogroup 1 was isolated from 10·5% of the hotels. The presence of Leg. pneumophila was significantly influenced by water sample temperature, while no association with water hardness or residual‐free chlorine was found. Conclusions: This study showed a high percentage of buildings colonized by Leg. pneumophila. Moreover, real‐time PCR proved to be sensitive enough to detect lower levels of contamination than the culture method. Significance and Impact of the Study: This study indicates that the Italian hotels represent a possible source of risk for Legionnaires’ disease and confirms the sensitivity of the molecular method. To our knowledge, this is the first report to demonstrate Legionella contamination in Italian hotels using real‐time PCR and culture methods.  相似文献   