首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

To examine changes in hamstring muscle fatigue and central motor output during a 90-minute simulated soccer match, and the concomitant changes in hamstring maximal torque and rate of torque development.

Method

Eight amateur male soccer players performed a 90-minute simulated soccer match, with measures performed at the start of and every 15-minutes during each half. Maximal torque (Nm) and rate of torque development (RTD; Nm.s–1) were calculated from maximal isometric knee flexor contractions performed at 10° of flexion. Hamstring peripheral fatigue was assessed from changes in the size and shape of the resting twitch (RT). Hamstring central motor output was quantified from voluntary activation (%) and normalized biceps femoris (BF) and medial hamstrings (MH) electromyographic amplitudes (EMG/M).

Results

Maximal torque was reduced at 45-minutes by 7.6±9.4% (p<0.05). RTD in time intervals of 0–25, 0–50, and 0–75 ms post-contraction onset were reduced after 15-minutes in the first-half between 29.6 to 46.2% (p<0.05), and were further reduced at the end of the second-half (p<0.05). Maximal EMG/M was reduced for biceps femoris only concomitant to the time-course of reductions in maximal torque (p = 0.007). The rate of EMG rise for BF and MH was reduced in early time periods (0–75 ms) post-contraction onset (p<0.05). No changes were observed for the size and shape of the RT, indicating no hamstring peripheral fatigue.

Conclusion

Centrally mediated reductions in maximal torque and rate of torque development provide insight into factors that may explain hamstring injury risk during soccer. Of particular interest were early reductions during the first-half of hamstring rate of torque development, and the decline in maximal EMG/M of biceps femoris in the latter stages of the half. These are important findings that may help explain why the hamstrings are particularly vulnerable to strain injury during soccer.  相似文献   

2.
Electromechanical delay (EMD) is the time lag between muscle activation and force development. Using very high frame rate ultrasound, both electrochemical and mechanical processes involved in EMD can be assessed. Percutaneous electrical stimulations at submaximal intensity are often used to stimulate a specific target muscle. The aim of this study was to determine whether stimulus intensity alters the delay between stimulation and the onset of muscle fascicules motion (Dm), the onset of myotendinous junction motion (Dt), and force production (EMD). Ten participants underwent two electrically evoked contractions, with the probe maintained either the biceps brachii muscle belly or the distal myotendinous junction of the biceps brachii, for six stimulus intensities (30%, 50%, 70%, 90%, 110% and 130% of the lowest intensity inducing the maximal involuntary force production, Imax). In addition, inter-day reliability was tested in nine participants at both 70% and 90% of Imax. Dm, Dt and EMD were significantly longer (p < 0.001) at very low (30% and 50% of Imax) compared to higher intensities (70%, 90%, 110% and 130% of Imax). Inter-day reliability of EMD, Dm, and Dt was good (coefficient of variation ranged from 6.8% to 12.5%, i.e. SEM lower than 0.79 ms). These results indicate that the stimulus intensity needs to be standardized to perform longitudinal evaluation and/or to make between-subject comparisons.  相似文献   

3.
The purpose of this study was to examine the acute effects of maximal concentric vs. eccentric exercise on the isometric strength of the elbow flexor, as well as the biceps brachii muscle electromyographic (EMG) responses in resistance-trained (RT) vs. untrained (UT) men. Thirteen RT men (age: 24 ± 4 years; height: 180.2 ± 7.7 cm; body weight: 92.2 ± 16.9 kg) and twelve UT men (age: 23 ± 4 years; height: 179.2 ± 5.0 cm; body weight: 81.5 ± 8.6 kg) performed six sets of ten maximal concentric isokinetic (CON) or eccentric isokinetic (ECC) elbow flexion exercise in two separate visits. Before and after the exercise interventions, maximal voluntary contractions (MVCs) were performed for testing isometric strength. In addition, bipolar surface EMG signals were detected from the biceps brachii muscle during the strength testing. Both CON and ECC caused isometric strength to decrease, regardless of the training status. However, ECC caused greater isometric strength decline than CON did for the UT group (p = 0.006), but not for the RT group. Both EMG amplitude and mean frequency significantly decreased and increased, respectively, regardless of the training status and exercise intervention. Resistance-trained men are less susceptible to eccentric exercise-induced muscle damage, but this advantage is not likely linked to the chronic resistance training-induced neural adaptations.  相似文献   

4.

Introduction

Beta-adrenoceptors (β-AR) play an important role in the neurohumoral regulation of cardiac function. Three β-AR subtypes (β1, β2, β3) have been described so far. Total deficiency of these adrenoceptors (TKO) results in cardiac hypotrophy and negative inotropy. TKO represents a unique mouse model mimicking total unselective medical β-blocker therapy in men. Electrophysiological characteristics of TKO have not yet been investigated in an animal model.

Methods

In vivo electrophysiological studies using right heart catheterisation were performed in 10 TKO mice and 10 129SV wild type control mice (WT) at the age of 15 weeks. Standard surface ECG, intracardiac and electrophysiological parameters, and arrhythmia inducibility were analyzed.

Results

The surface ECG of TKO mice revealed a reduced heart rate (359.2±20.9 bpm vs. 461.1±33.3 bpm; p<0.001), prolonged P wave (17.5±3.0 ms vs. 15.1±1.2 ms; p = 0.019) and PQ time (40.8±2.4 ms vs. 37.3±3.0 ms; p = 0.013) compared to WT. Intracardiac ECG showed a significantly prolonged infra-Hisian conductance (HV-interval: 12.9±1.4 ms vs. 6.8±1.0 ms; p<0.001). Functional testing showed prolonged atrial and ventricular refractory periods in TKO (40.5±15.5 ms vs. 21.3±5.8 ms; p = 0.004; and 41.0±9.7 ms vs. 28.3±6.6 ms; p = 0.004, respectively). In TKO both the probability of induction of atrial fibrillation (12% vs. 24%; p<0.001) and of ventricular tachycardias (0% vs. 26%; p<0.001) were significantly reduced.

Conclusion

TKO results in significant prolongations of cardiac conduction times and refractory periods. This was accompanied by a highly significant reduction of atrial and ventricular arrhythmias. Our finding confirms the importance of β-AR in arrhythmogenesis and the potential role of unspecific beta-receptor-blockade as therapeutic target.  相似文献   

5.
Antagonistic muscle pairs cannot be fully activated simultaneously, even with maximal effort, under conditions of voluntary co-contraction, and their muscular activity levels are always below those during agonist contraction with maximal voluntary effort (MVE). Whether the muscular activity level during the task has trainability remains unclear. The present study examined this issue by comparing the muscular activity level during maximal voluntary co-contraction for highly experienced bodybuilders, who frequently perform voluntary co-contraction in their training programs, with that for untrained individuals (nonathletes). The electromyograms (EMGs) of biceps brachii and triceps brachii muscles during maximal voluntary co-contraction of elbow flexors and extensors were recorded in 11 male bodybuilders and 10 nonathletes, and normalized to the values obtained during the MVE of agonist contraction for each of the corresponding muscles (% EMGMVE). The involuntary coactivation level in antagonist muscle during the MVE of agonist contraction was also calculated. In both muscles, % EMGMVE values during the co-contraction task for bodybuilders were significantly higher (P<0.01) than those for nonathletes (biceps brachii: 66±14% in bodybuilders vs. 46±13% in nonathletes, triceps brachii: 74±16% vs. 57±9%). There was a significant positive correlation between a length of bodybuilding experience and muscular activity level during the co-contraction task (r = 0.653, P = 0.03). Involuntary antagonist coactivation level during MVE of agonist contraction was not different between the two groups. The current result indicates that long-term participation in voluntary co-contraction training progressively enhances muscular activity during maximal voluntary co-contraction.  相似文献   

6.

Background

Although the assessment of diastolic dysfunction (DD) is an integral part of routine cardiologic examinations, little is known about associated electrocardiographic (ECG) changes. Our aim was to investigate a potential role of ECG indices for the recognition of patients with DD.

Methods and Results

ECG parameters correlating with echocardiographic findings of DD were retrospectively assessed in a derivation group of 172 individuals (83 controls with normal diastolic function, 89 patients with DD) and their diagnostic performance was tested in a validation group of 50 controls and 50 patients. The patient group with a DD Grade 1 and 2 showed longer QTc (422±24ms and 434±32ms vs. 409±25ms, p<0.0005) and shorter Tend–P and Tend–Q intervals, reflecting the electrical and mechanical diastole (240±78ms and 276±108ms vs. 373±110ms, p<0.0001; 409±85ms and 447±115ms vs. 526±119ms, p<0.0001). The PQ–interval was significantly longer in the patient group (169±28ms and 171±38ms vs. 153±22ms, p<0.005). After adjusting for possible confounders, a novel index (Tend–P/[PQxAge]) showed a high performance for the recognition of DD, stayed robust in the validation group (sensitivity 82%, specificity 93%, positive predictive value 93%, negative predictive value 82%, accuracy 88%) and proved a substantial added value when combined with the indexed left atrial volume (LAESVI, sensitivity 90%, specificity 92%, positive predictive value 95%, negative predictive value 86%, accuracy 91%).

Conclusions

A novel electrocardiographic index Tend–P/(PQxAge) demonstrates a high diagnostic accuracy for the diagnosis of DD and yields a substantial added value when combined with the LAESVI.  相似文献   

7.
8.

Objective

To study the mechanism of the no-reflow phenomenon using coronary angiography (CAG) and intravascular ultrasound (IVUS).

Methods

A total of 120 patients with acute myocardial infarction (AMI) who successfully underwent indwelling intracoronary stent placement by percutaneous coronary intervention (PCI). All patients underwent pre- and post-PCI CAG and pre-IVUS. No-reflow was defined as post-PCI thrombolysis in myocardial infarction (TIMI) grade 0, 1, or 2 flow in the absence of mechanical obstruction. Normal reflow was defined as TIMI grade 3 flow. The pre-operation reference vascular area, minimal luminal cross-sectional area, plaque cross-sectional area, lesion length, plaque volume and plaque traits were measured by IVUS.

Results

The no-reflow group was observed in 14 cases (11.6%) and normal blood-flow group in 106 cases (89.4%) based on CAG results. There was no statistically significant difference in the patients’ medical history, reference vascular area (no-flow vs. normal-flow; 15.5 ± 3.2 vs. 16.2 ± 3.3, p> 0.05) and lesion length (21.9 ± 5.1 vs. 19.5 ± 4.8, p> 0.05) between the two groups. No-reflow patients had a longer symptom onset to reperfusion time compared to normal blood-flow group [(6.6 ± 3.1) h vs (4.3 ± 2.7) h; p< 0.05] and higher incidence of TIMI flow grade< 3 (71.4% vs 49.0%, p< 0.05). By IVUS examination, the no-reflow group had a significantly increased coronary plaque area and plaque volume compared to normal blood-flow group [(13.7 ± 3.0) mm2 vs (10.2 ± 2.9) mm2; (285.4 ± 99.8) mm3 vs (189.7 ± 86.4) mm3; p< 0.01]. The presence of IVUS-detected soft plaque (57.1% vs. 24.0%, p< 0.01), eccentric plaque (64.2% vs. 33.7%, p< 0.05), plaque rupture (50.0% vs. 21.2%, p< 0.01), and thrombosis (42.8% vs. 15.3%) were significantly more common in no-reflow group.

Conclusion

There was no obvious relationship between the coronary risk factors and no-reflow phenomenon. The symptom onset to reperfusion time, TIMI flow grade before stent deployment, plaque area, soft plaques, eccentric plaques, plaque rupture and thrombosis may be risk factors for the no-reflow phenomenon after PCI.  相似文献   

9.

Background

Obesity is an important risk factor for atrial fibrillation (AF). Leptin is an important adipokine. However, it is not clear whether leptin directly modulates the electrophysiological characteristics of atrial myocytes.

Results

Whole cell patch clamp and indo-1 fluorescence were used to record the action potentials (APs) and ionic currents in isolated rabbit left atrial (LA) myocytes incubated with and without (control) leptin (100 nM) for 1 h to investigate the role of leptin on atrial electrophysiology. Leptin-treated LA myocytes (n = 19) had longer 20% of AP duration (28 ± 3 vs. 21 ± 2 ms, p < 0.05), but similar 50% of AP duration (51 ± 4 vs. 50 ± 3 ms, p > 0.05), and 90% of AP duration (89 ± 5 vs. 94 ± 4 ms, p > 0.05), as compared to the control (n = 22). In the presence of isoproterenol (10 nM), leptin-treated LA myocytes (n = 21) showed a lower incidence (19% vs. 54.2%, p < 0.05) of delayed afterdepolarization (DAD) than the control (n = 24). Leptin-treated LA myocytes showed a larger sodium current, but a smaller ultra-rapid delayed rectifier potassium current, and sodium-calcium exchanger current than the control. Leptin-treated and control LA myocytes exhibited a similar late sodium current, inward rectifier potassium current, transient outward current and L-type calcium current. In addition, the leptin-treated LA myocytes (n = 38) exhibited a smaller intracellular Ca2+ transient (0.21 ± 0.01 vs. 0.26 ± 0.01 R410/485, p < 0.05) and sarcoplasmic reticulum Ca2+ content (0.35 ± 0.02 vs. 0.43 ± 0.03 R410/485, p < 0.05) than the control LA myocytes (n = 42).

Conclusions

Leptin regulates the LA electrophysiological characteristics and attenuates isoproterenol-induced arrhythmogenesis.  相似文献   

10.

Purpose

To analyze if tumor vessels can be visualized, segmented and quantified in glioblastoma patients with time of flight (ToF) angiography at 7 Tesla and multiscale vessel enhancement filtering.

Materials and Methods

Twelve patients with newly diagnosed glioblastoma were examined with ToF angiography (TR = 15 ms, TE = 4.8 ms, flip angle = 15°, FOV = 160×210 mm2, voxel size: 0.31×0.31×0.40 mm3) on a whole-body 7 T MR system. A volume of interest (VOI) was placed within the border of the contrast enhancing part on T1-weighted images of the glioblastoma and a reference VOI was placed in the non-affected contralateral white matter. Automated segmentation and quantification of vessels within the two VOIs was achieved using multiscale vessel enhancement filtering in ImageJ.

Results

Tumor vessels were clearly visible in all patients. When comparing tumor and the reference VOI, total vessel surface (45.3±13.9 mm2 vs. 29.0±21.0 mm2 (p<0.035)) and number of branches (3.5±1.8 vs. 1.0±0.6 (p<0.001) per cubic centimeter were significantly higher, while mean vessel branch length was significantly lower (3.8±1.5 mm vs 7.2±2.8 mm (p<0.001)) in the tumor.

Discussion

ToF angiography at 7-Tesla MRI enables characterization and quantification of the internal vascular morphology of glioblastoma and may be used for the evaluation of therapy response within future studies.  相似文献   

11.

Objective

To investigate whether fatigue induced by an intermittent motor task in patients with cancer-related fatigue (CRF) is more central or peripheral.

Methods

Ten patients with CRF who were off chemo and radiation therapies and 14 age-matched healthy controls were enrolled. Participants completed a Brief Fatigue Inventory (BFI) and performed a fatigue task consisting of intermittent elbow-flexion contractions at submaximal (40% maximal voluntary contraction) intensity till self-perceived exhaustion. Twitch force was elicited by an electrical stimulation applied to the biceps brachii muscle. The relative degree of peripheral (muscle) vs. central contribution to fatigue induced by the intermittent motor task (IMT) was assessed using twitch force ratio (TFratio) defined as post IMT twitch force to pre IMT twitch force. The total number of trials (intermittent contractions) and total duration of all trials performed by each subject were also quantified.

Results

BFI scores were higher (p<0.001) in CRF than controls, indicating greater feeling of fatigue in CRF patients than controls. A significantly smaller number of trials and shorter total duration of the trials (p<0.05) were observed in CRF than control participants. The TFratio (0.81±0.05) in CRF was higher (p<0.05) compared with that of controls (0.62±0.05), suggesting CRF patients experienced a significantly lower degree of muscle (peripheral) fatigue at the time of perceived exhaustion.

Conclusion

Consistent with prior findings for fatigue under submaximal sustained contraction, our results indicate that motor fatigue in CRF is more of central than peripheral origin during IMT. Significant central fatigue in CRF patients limits their ability to prolong motor performance.  相似文献   

12.

Background

To assess regional systolic function and global contractile function in patients with WPW Syndrome.

Method

Eleven cases with manifest Wolff-Parkinson-White (WPW) syndrome in sinus rhythm were compared to 11 age matched controls. 2D strain analysis was performed and peak segmental radial strain (pRS) values obtained from basal ventricular parasternal short-axis images (70 ± 5 frames/sec) using a dedicated software package. Heterogeneity of radial strain pattern in six circumferential basal left ventricular segments was measured in terms of standard deviations of peak RS (SDpRS) or range (difference between maximum and minimum peak RS i.e. RangepRS). Spectral Doppler (continuous wave) measurements were acquired through the left ventricular outflow tract to determine Pre Ejection Period (PEP), Left Ventricular Ejection Time (LVET) and measures of left ventricular systolic performance.

Results

LV segmental radial strain was profoundly heterogeneous in WPW cases in contrast to fairly homogenous strain pattern in normal subjects. Wide SDpRS values 17.5 ± 8.9 vs 3.3 ± 1.4, p<0.001 and RangepRS 42.7 ± 20.8 vs.8.5 ± 3.6 , p<0.001 were observed among WPW and healthy subjects respectively. PEP (132.4 ± 14.7 vs 4.7 ± 0.5ms, p<0.001) and corrected PEP (76.1 ± 8.0 vs 2.7 ± 0.4ms, p<0.001) were significantly longer in WPW patients compared to controls. The PEP/LVET ratio was also significantly greater in WPW cohort (0.49 ± 0.04 vs. 0.28 ± 0.05, p <0.001) suggesting global systolic dysfunction.

Conclusions

Patients with manifest preexcitation (predominantly those with right-sided pathways) have regional and global contractile dysfunction resulting from aberrant impulse propagation inherent to the preexcited state.  相似文献   

13.

Background

Biventricular (BiV) is extensively used in the treatment of congestive heart failure but so far no recommendations for optimized programming of atrioventricular-delay (AVD) settings have been proposed. Can AVD optimization be performed using a simple formula based on non-invasive doppler-echocardiography?

Methods

25 patients (ejection fraction 30±8%) received BiV ICDs. Doppler-echocardiographic evaluation of diastolic and systolic flow was performed for different AVDs (30ms to 150ms) and different stimulation sites (left ventricular (LV), right ventricular and BiV). The optimal atrioventricular delay was calculated applying a simple formula based on systolic and diastolic mechanical delays determined during doppler-echocardiography.

Results

The mean optimal AVD was calculated to be 112±29ms (50 to 180ms) for BiV, 95±30ms (65 to 150ms) for LV and 75±28ms (40 to 125ms) for right ventricular pacing with wide interindividual variations. Compared to suboptimal AVDs diastolic optimization improved preejection and ejection intervals independent to pacing site. Optimization of the AVD significantly increased ejection time during BiV pacing (279ms versus 266ms; p<0.05). Compared to LV or right ventricular pacing BiV pacing produced the shortest mean pre-ejection and longest ejection intervals as parameters of improved systolic ventricular contractile synchrony. Diastolic filling times were longest during BiV pacing compared to LV or RV pacing.

Conclusions

Individual programming of BiV pacing devices increases hemodynamic benefit when implementing the inter-individually widely varying electromechanical delays. Optimization applying a simple formula not only improves diastolic ventricular filling but also increases systolic functional parameters.  相似文献   

14.

Background

Telomeres are potential markers of mitotic cellular age and are associated with physical ageing process. Long-term endurance training and higher aerobic exercise capacity (VO2max) are associated with improved survival, and dynamic effects of exercise are evident with ageing. However, the association of telomere length with exercise training and VO2max has so far been inconsistent. Our aim was to assess whether muscle telomere length is associated with endurance exercise training and VO2max in younger and older people.

Methods

Twenty men; 10 young (22–27 years) and 10 old (66–77 years), were studied in this cross-sectional study. Five out of 10 young adults and 5 out of 10 older were endurance athletes, while other halves were exercising at a medium level of activity. Mean telomere length was measured as telomere/single copy gene-ratio (T/S-ratio) using quantitative real time polymerase chain reaction. VO2max was measured directly running on a treadmill.

Results

Older endurance trained athletes had longer telomere length compared with older people with medium activity levels (T/S ratio 1.12±0.1 vs. 0.92±0.2, p = 0.04). Telomere length of young endurance trained athletes was not different than young non-athletes (1.47±0.2 vs. 1.33±0.1, p = 0.12). Overall, there was a positive association between T/S ratio and VO2max (r = 0.70, p = 0.001). Among endurance trained athletes, we found a strong correlation between VO2max and T/S ratio (r = 0.78, p = 0.02). However, corresponding association among non-athlete participants was relatively weak (r = 0.58, p = 0.09).

Conclusion

Our data suggest that VO2max is positively associated with telomere length, and we found that long-term endurance exercise training may provide a protective effect on muscle telomere length in older people.  相似文献   

15.

Introduction

Surface electromyography (sEMG) is the measurement of the electrical activity of the skeletal muscle tissue detected at the skin’s surface. Typically, a bipolar electrode configuration is used. Most muscles have pennate and/or curved fibres, meaning it is not always feasible to align the bipolar electrodes along the fibres direction. Hence, there is a need to explore how different electrode designs can affect sEMG measurements.

Method

A three layer finite element (skin, fat, muscle) muscle model was used to explore different electrode designs. The implemented model used as source signal an experimentally recorded intramuscular EMG taken from the biceps brachii muscle of one healthy male. A wavelet based intensity analysis of the simulated sEMG signal was performed to analyze the power of the signal in the time and frequency domain.

Results

The model showed muscle tissue causing a bandwidth reduction (to 20-92- Hz). The inter-electrode distance (IED) and the electrode orientation relative to the fibres affected the total power but not the frequency filtering response. The effect of significant misalignment between the electrodes and the fibres (60°- 90°) could be reduced by increasing the IED (25–30 mm), which attenuates signal cancellation. When modelling pennated fibres, the muscle tissue started to act as a low pass filter. The effect of different IED seems to be enhanced in the pennated model, while the filtering response is changed considerably only when the electrodes are close to the signal termination within the model. For pennation angle greater than 20°, more than 50% of the source signal was attenuated, which can be compensated by increasing the IED to 25 mm.

Conclusion

Differences in tissue filtering properties, shown in our model, indicates that different electrode designs should be considered for muscle with different geometric properties (i.e. pennated muscles).  相似文献   

16.

Purpose

To investigate corneal sensitivity to selective mechanical, chemical, and thermal stimulation and to evaluate their relation to dry eye symptoms in patients with keratoconus.

Methods

Corneal sensitivity to mechanical, chemical, and thermal thresholds were determined using a gas esthesiometer in 19 patients with keratoconus (KC group) and in 20 age-matched healthy subjects (control group). Tear film dynamics was assessed by Schirmer I test and by the non-invasive tear film breakup time (NI-BUT). All eyes were examined with a rotating Scheimpflug camera to assess keratoconus severity.

Results

KC patients had significatly decreased tear secretion and significantly higher ocular surface disease index (OSDI) scores compared to controls (5.3±2.2 vs. 13.2±2.0 mm and 26.8±15.8 vs. 8.1±2.3; p<0.001). There was no significant difference in NI-BUT between the two groups (KC: 9.8±4.8 vs. control: 10.7±3.8; p>0.05). The mean threshold for selective mechanical (KC: 139.2±25.8 vs. control: 109.1±24.0 ml/min), chemical (KC: 39.4±3.9 vs. control: 35.2±1.9%CO2), heat (KC: 0.91±0.32 vs. control: 0.54±0.26 Δ°C) and cold (KC: 1.28±0.27 vs. control: 0.98±0.25 Δ°C) stimulation in the KC patients were significantly higher than in the control subjects (p<0.001, for all parameters). No correlation was found between age and mechanical, chemical, heat or cold thresholds in the patients with KC (p>0.05), whereas in the control subjects both mechanical (r = 0.52, p = 0.02), chemical (r = 0.47, p = 0.04), heat (r = 0.26, p = 0.04) and cold threshold (r = 0.40, p = 0.03) increased with age. In the KC group, neither corneal thickness nor tear flow, NI-BUT or OSDI correlated significantly with mechanical, chemical, heat or cold thresholds (p>0.05 for all variables).

Conclusions

Corneal sensitivity to different types of stimuli is decreased in patients with keratoconus independently of age and disease severity. The reduction of the sensory input from corneal nerves may contribute to the onset of unpleasant sensations in these patients and might lead to the impaired tear film dynamics.  相似文献   

17.
The present work aimed at investigating the effects of mechanically amplified tremor on cortico-muscular coherence (CMC) in the alpha band. The study of CMC in this specific band is of particular interest because this coherence is usually absent in healthy individuals and it is an aberrant feature in patients affected by pathological tremors; understanding its mechanisms is therefore important. Thirteen healthy volunteers (23±4 years) performed elbow flexor sustained contractions both against a spring load and in isometric conditions at 20% of maximal voluntary isometric contraction (MVC). Spring stiffness was selected to induce instability in the stretch reflex servo loop. 64 EEG channels, surface EMG from the biceps brachii muscle and force were simultaneously recorded. Contractions against the spring resulted in greater fluctuations of the force signal and EMG amplitude compared to isometric conditions (p<.05). During isometric contractions CMC was systematically found in the beta band and sporadically observed in the alpha band. However, during the contractions against the spring load, CMC in the alpha band was observed in 12 out of 13 volunteers. Partial directed coherence (PDC) revealed an increased information flow in the EMG to EEG direction in the alpha band (p<.05). Therefore, coherence in the alpha band between the sensory-motor cortex and the biceps brachii muscle can be systematically induced in healthy individuals by mechanically amplifying tremor. The increased information flow in the EMG to EEG direction may reflect enhanced afferent activity from the muscle spindles. These results may contribute to the understanding of the presence of alpha band CMC in tremor related pathologies by suggesting that the origin of this phenomenon may not only be at cortical level but may also be affected by spinal circuit loops.  相似文献   

18.

Introduction

Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an ablation catheter with enhanced tip irrigation.

Methods

A total of 59 patients were included in the analysis. In 30 patients circumferential PVI was performed using the Thermocool Smarttouch® ablation catheter (ST) whereas in 29 patients circumferential PVI using the Thermocool Surround Flow SF® ablation catheter (SF) was performed. Patients were compared in regard to procedure time, fluoroscopy time/dose as well as RF-application duration and completeness of PVI. Adverse events (pericardial effusion, PV stenosis, stroke, death) were evaluated. The presence of sinus rhythm off antiarrhythmic medication was assessed during 6 months follow-up using multiple 7 day Holter-ECGs.

Results

In both groups, all PVs were isolated without serious adverse events. Procedure time was 2.15 ± 0.5 h (ST) vs. 2.37 ± 1.13 h (SF) (p = 0.19). Duration of RF-applications was 46.6 ± 18 min (ST) and 49.8 ± 19 min (SF) (p = 0.52). Fluoroscopy time was 25.2 ± 13 min (ST) vs. 29 ± 18 min (SF), fluoroscopy dose 2675.6 ± 1658 versus 3038.3 ± 1997 cGym2 (p = 0.36 and 0.46 respectively). Sinus rhythm off antiarrhythmic medication validated with 7 day Holter ECGs was present in both groups in 72% of patients after 6 months of follow up.

Conclusion

PVI using the new contact force catheter is safe and effective in patients with paroxysmal AF.  相似文献   

19.

Aims

The concealed phase of arrhythmogenic right ventricular cardiomyopathy (ARVC) may initially manifest electrophysiologically. No studies have examined dynamic conduction/repolarization kinetics to distinguish benign right ventricular outflow tract ectopy (RVOT ectopy) from ARVC''s early phase. We investigated dynamic endocardial electrophysiological changes that differentiate early ARVC disease expression from RVOT ectopy.

Methods

22 ARVC (12 definite based upon family history and mutation carrier status, 10 probable) patients without right ventricular structural anomalies underwent high-density non-contact mapping of the right ventricle. These were compared to data from 14 RVOT ectopy and 12 patients with supraventricular tachycardias and normal hearts. Endocardial & surface ECG conduction and repolarization parameters were assessed during a standard S1-S2 restitution protocol.

Results

Definite ARVC without RV structural disease could not be clearly distinguished from RVOT ectopy during sinus rhythm or during steady state pacing. Delay in Activation Times at coupling intervals just above the ventricular effective refractory period (VERP) increased in definite ARVC (43±20 ms) more than RVOT ectopy patients (36±14 ms, p = 0.03) or Normals (25±16 ms, p = 0.008) and a progressive separation of the repolarisation time curves between groups existed. Repolarization time increases in the RVOT were also greatest in ARVC (definite ARVC: 18±20 ms; RVOT ectopy: 5±14, Normal: 1±18, p<0.05). Surface ECG correlates of these intracardiac measurements demonstrated an increase of greater than 48 ms in stimulus to surface ECG J-point pre-ERP versus steady state, with an 88% specificity and 68% sensitivity in distinguishing definite ARVC from the other groups. This technique could not distinguish patients with genetic predisposition to ARVC only (probable ARVC) from controls.

Conclusions

Significant changes in dynamic conduction and repolarization are apparent in early ARVC before detectable RV structural abnormalities, and were present to a lesser degree in probable ARVC patients. Investigation of dynamic electrophysiological parameters may be useful to identify concealed ARVC in patients without disease pedigrees by using endocardial electrogram or paced ECG parameters.  相似文献   

20.

Background

Vitamin D has effects on the innate and adaptive immune system. In asthmatic children low vitamin D levels are associated with poor asthma control, reduced lung function, increased medication intake, and exacerbations. Little is known about vitamin D in adult asthma patients or its association with asthma severity and control.

Methods

Clinical parameters of asthma control and 25-hydroxyvitamin D (25(OH)D) serum concentrations were evaluated in 280 adult asthma patients (mean ± SD: 45.0 ± 13.8 yrs., 40% male, FEV1 74.9 ± 23.4%, 55% severe, 51% uncontrolled).

Results

25(OH)D concentrations in adult asthmatics were low (25.6 ±11.8 ng/ml) and vitamin D insufficiency or deficiency (vitamin D <30 ng/ml) was common (67%). 25(OH)D levels were related to asthma severity (intermittent: 31.1 ± 13.0 ng/ml, mild: 27.3 ± 11.9 ng/ml, moderate: 26.5 ± 12.0 ng/ml, severe: 24.0 ± 11.8 ng/ml, p = 0.046) and control (controlled: 29.5 ± 12.5 ng/ml, partly controlled 25.9 ± 10.8 ng/ml, uncontrolled: 24.2 ± 11.8 ng/ml, p = 0.030). The frequency of vitamin D insufficiency or deficiency was significantly higher in patients with severe or uncontrolled asthma and was associated with a lower FEV1 (vitamin D <30 vs. ≥30 ng/ml 2.3 ± 0.9 L vs. 2.7 ± 1.0 L, p = 0.006), higher levels of exhaled NO (45 ± 46 ppb vs. 31 ± 37 ppb, p = 0.023), a higher BMI (28.3 ± 6.2 vs. 25.1 ± 3.9, p < 0.001), and sputum eosinophilia (5.1 ± 11.8% vs. 0.5 ± 1.0%, p = 0.005). The use of oral corticosteroids or sputum eosinophilia was associated with a 20% or 40% higher risk of vitamin D insufficiency or deficiency.

Conclusions

25(OH)D levels below 30 ng/ml are common in adult asthma and most pronounced in patients with severe and/or uncontrolled asthma, supporting the hypothesis that improving suboptimal vitamin D status might be effective in prevention and treatment of asthma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号