首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Soft X-ray tomography (SXT) is an imaging technique capable of characterizing and quantifying the structural phenotype of cells. In particular, SXT is used to visualize the internal architecture of fully hydrated, intact eukaryotic and prokaryotic cells at high spatial resolution (50 nm or better). Image contrast in SXT is derived from the biochemical composition of the cell, and obtained without the need to use potentially damaging contrast-enhancing agents, such as heavy metals. The cells are simply cryopreserved prior to imaging, and are therefore imaged in a near-native state. As a complement to structural imaging by SXT, the same specimen can now be imaged by correlated cryo-light microscopy. By combining data from these two modalities specific molecules can be localized directly within the framework of a high-resolution, three-dimensional reconstruction of the cell. This combination of data types allows sophisticated analyses to be carried out on the impact of environmental and/or genetic factors on cell phenotypes.  相似文献   

2.
We present a new method for whole slide darkfield imaging. Whole Slide Imaging (WSI), also sometimes called virtual slide or virtual microscopy technology, produces images that simultaneously provide high resolution and a wide field of observation that can encompass the entire section, extending far beyond any single field of view. For example, a brain slice can be imaged so that both overall morphology and individual neuronal detail can be seen. We extended the capabilities of traditional whole slide systems and developed a prototype system for darkfield internal reflection illumination (DIRI). Our darkfield system uses an ultra-thin light-emitting diode (LED) light source to illuminate slide specimens from the edge of the slide. We used a new type of side illumination, a variation on the internal reflection method, to illuminate the specimen and create a darkfield image. This system has four main advantages over traditional darkfield: (1) no oil condenser is required for high resolution imaging (2) there is less scatter from dust and dirt on the slide specimen (3) there is less halo, providing a more natural darkfield contrast image, and (4) the motorized system produces darkfield, brightfield and fluorescence images. The WSI method sometimes allows us to image using fewer stains. For instance, diaminobenzidine (DAB) and fluorescent staining are helpful tools for observing protein localization and volume in tissues. However, these methods usually require counter-staining in order to visualize tissue structure, limiting the accuracy of localization of labeled cells within the complex multiple regions of typical neurohistological preparations. Darkfield imaging works on the basis of light scattering from refractive index mismatches in the sample. It is a label-free method of producing contrast in a sample. We propose that adapting darkfield imaging to WSI is very useful, particularly when researchers require additional structural information without the use of further staining.  相似文献   

3.
2dx--user-friendly image processing for 2D crystals   总被引:1,自引:0,他引:1  
  相似文献   

4.

Background

Despite its superb lateral resolution, flat-panel-detector (FPD) based tomosynthesis suffers from low contrast and inter-plane artifacts caused by incomplete cancellation of the projection components stemming from outside the focal plane. The incomplete cancellation of the projection components, mostly due to the limited scan angle in the conventional tomosynthesis scan geometry, often makes the image contrast too low to differentiate the malignant tissues from the background tissues with confidence.

Methods

In this paper, we propose a new method to suppress the inter-plane artifacts in FPD-based tomosynthesis. If 3D whole volume CT images are available before the tomosynthesis scan, the CT image data can be incorporated into the tomosynthesis image reconstruction to suppress the inter-plane artifacts, hence, improving the image contrast. In the proposed technique, the projection components stemming from outside the region-of-interest (ROI) are subtracted from the measured tomosynthesis projection data to suppress the inter-plane artifacts. The projection components stemming from outside the ROI are calculated from the 3D whole volume CT images which usually have lower lateral resolution than the tomosynthesis images. The tomosynthesis images are reconstructed from the subtracted projection data which account for the x-ray attenuation through the ROI. After verifying the proposed method by simulation, we have performed both CT scan and tomosynthesis scan on a phantom and a sacrificed rat using a FPD-based micro-CT.

Results

We have measured contrast-to-noise ratio (CNR) from the tomosynthesis images which is an indicator of the residual inter-plane artifacts on the focal-plane image. In both cases of the simulation and experimental imaging studies of the contrast evaluating phantom, CNRs have been significantly improved by the proposed method. In the rat imaging also, we have observed better visual contrast from the tomosynthesis images reconstructed by the proposed method.

Conclusions

The proposed tomosynthesis technique can improve image contrast with aids of 3D whole volume CT images. Even though local tomosynthesis needs extra 3D CT scanning, it may find clinical applications in special situations in which extra 3D CT scan is already available or allowed.  相似文献   

5.
Three-dimensional electron tomographic studies of thick specimens such as cellular organelles or supramolecular structures require accurate interpretations of transmission electron micrograph intensities. In addition to microscope lens aberrations, thick specimen imaging is complicated by additional distortions resulting from multiple elastic and inelastic scattering. Extensive analysis of the mechanism of image formation using electron energy-loss spectroscopy and imaging as well as exit wavefront reconstruction demonstrated that multiple scattering does not contribute to the coherent component of the exit wave (Hanet al.,1996, 1995). Although exit wavefront restored images showed enhanced contrast and resolution, that technique, which requires the collection of more than 30 images at different focus levels, is not practical for routine data collection in 3D electron tomography, where usually over 100 projection views are required for each reconstruction. Using a 0.7-μm-thick specimen imaged at 200 keV, the accuracy of reconstructions using small numbers of defocused images and a simple linear filter (Schiske, 1968) was assessed by comparison to the complete exit wave restoration. We demonstrate that only four optimal focus levels are required to effectively restore the coherent component (deviation 5.1%). By contrast, the optimal single image (zero defocus) shows a 25.5% deviation to the exit wave restoration. Two pairs of under- and over-defocus images should be taken: one pair at quite high defocus (>10 μm) to differentiate the coherent (single elastic scattering) from the incoherent (multiple elastic and inelastic scattering) components, and the second pair to optimize information content at the highest desired resolution (e.g., 5 μm for (2.5 nm)−1resolution). We also propose a new interpretation of the restored amplitude and phase components where the specimen mass-density is proportional to the logarithm of the amplitude component and linearly related to the phase component. This approach should greatly facilitate the collection of high resolution tomographic data from thick samples.  相似文献   

6.
X-ray phase-contrast computed tomography is an emerging imaging technology with powerful capabilities for three-dimensional (3D) visualization of weakly absorbing objects such as biological soft tissues. This technique is an extension of existing X-ray applications because conventional attenuation-contrast images are simultaneously acquired. The complementary information provided by both the contrast modalities suggests that enhanced material characterization is possible when performing combined data analysis. In this study, we describe how protein, lipid, and water concentrations in each 3D voxel can be quantified by vector decomposition. Experimental results of dairy products, porcine fat and rind, and different human soft tissue types are presented. The results demonstrate the potential of phase-contrast imaging as a new analysis tool. The 3D representations of protein, lipid, and water contents open up new opportunities in the fields of biology, medicine, and food science.  相似文献   

7.
X-ray imaging offers a new 3-D view into cells. With its ability to penetrate whole hydrated cells it is ideally suited for pairing fluorescence light microscopy and nanoscale X-ray tomography. In this paper, we describe the X-ray optical set-up and the design of the cryo full-field transmission X-ray microscope (TXM) at the electron storage ring BESSY II. Compared to previous TXM set-ups with zone plate condenser monochromator, the new X-ray optical layout employs an undulator source, a spherical grating monochromator and an elliptically shaped glass capillary mirror as condenser. This set-up improves the spectral resolution by an order of magnitude. Furthermore, the partially coherent object illumination improves the contrast transfer of the microscope compared to incoherent conditions. With the new TXM, cells grown on flat support grids can be tilted perpendicular to the optical axis without any geometrical restrictions by the previously required pinhole for the zone plate monochromator close to the sample plane. We also developed an incorporated fluorescence light microscope which permits to record fluorescence, bright field and DIC images of cryogenic cells inside the TXM. For TXM tomography, imaging with multi-keV X-rays is a straightforward approach to increase the depth of focus. Under these conditions phase contrast imaging is necessary. For soft X-rays with shrinking depth of focus towards 10nm spatial resolution, thin optical sections through a thick specimen might be obtained by deconvolution X-ray microscopy. As alternative 3-D X-ray imaging techniques, the confocal cryo-STXM and the dual beam cryo-FIB/STXM with photoelectron detection are proposed.  相似文献   

8.
MITICS is a new software developed for MALDI imaging. We tried to render this software compatible with all types of instruments. MITICS is divided in two parts: MITICS control for data acquisition and MITICS Image for data processing and images reconstruction. MITICS control is available for Applied BioSystems MALDI-TOF instruments and MITICS Image for both Applied BioSystems and Bruker Daltonics ones. MITICS Control provides an interface to the user for setting the acquisition parameters for the imaging sequence, namely set instruments acquisition parameters, create the raster of acquisition and control post-acquisition data processing, and provide this settings to the automatic acquisition software of the MALDI instrument. MITICS Image ensures image reconstruction, files are first converted to XML files before being loaded in a database. In MITICS image we have chosen to implement different data representations and calculations for image reconstruction. MITICS Image uses three different representations that have shown to ease extraction of information from the whole data set. It also offers image reconstruction base either on the maximum peak intensity or the peak area. Image reconstruction is possible for single ions but also by summing signals of different ions. MITICS was validated on biological cases.  相似文献   

9.
This paper describes an X-ray phase contrast imaging technique using analyzer-based optics called X-ray Dark-Field Imaging that has been under development for the past 10 years. We describe the theory behind XDFI, the X-ray optics required for implementing it in practice, and algorithms used for 2D, 2.5D, and 3D image reconstruction. The XDFI optical chain consists of an asymmetrically cut, Bragg-type monochromator-collimator that provides a planar monochromatic X-ray beam, a positioning stage for the specimens, a Laue-case angle analyzer, and one or two cameras to capture the dark and bright field images. We demonstrate the soft-tissue discrimination capabilities of XDFI by reconstructing images with absorption and phase contrast. By using a variety of specimens such as breast tissue with cancer, joints with articular cartilage, ex-vivo human eye specimen, and others, we show that refraction-based contrast derived from XDFI is more effective in characterizing anatomical features, articular pathology, and neoplastic disease than conventional absorption-based images. For example, XDFI of breast tissue can discriminate between the normal and diseased terminal duct lobular unit, and between invasive and in-situ cancer. The final section of this paper is devoted to potential future developments to enable clinical and histo-pathological applications of this technique.  相似文献   

10.
In the context of cell biology, the term mesoscale describes length scales ranging from that of an individual cell, down to the size of the molecular machines. In this spatial regime, small building blocks self‐organise to form large, functional structures. A comprehensive set of rules governing mesoscale self‐organisation has not been established, making the prediction of many cell behaviours difficult, if not impossible. Our knowledge of mesoscale biology comes from experimental data, in particular, imaging. Here, we explore the application of soft X‐ray tomography (SXT) to imaging the mesoscale, and describe the structural insights this technology can generate. We also discuss how SXT imaging is complemented by the addition of correlative fluorescence data measured from the same cell. This combination of two discrete imaging modalities produces a 3D view of the cell that blends high‐resolution structural information with precise molecular localisation data.  相似文献   

11.
本研究以云南寒武纪澄江生物群节肢动物周小姐虫(Misszhouia longicaudata)为例,使用显微CT(Computed Tomography,计算机断层扫描的简写)技术对其保存在化石围岩内部的结构信息进行提取。通过Drishti软件对CT数据进行处理后,研究者可以在不破坏标本的前提下复原该动物腿肢较为完整的三维细节。此研究方法一方面对传统研究方法进行了重要补充,另一方面在研究中也对保存精美的澄江生物群化石起到保护作用,对这类标本的研究和保护具有重要意义。  相似文献   

12.
  1. Photogrammetric studies of free-ranging animals are limited to mammals and birds. Recent advances in insect photogrammetry, including 3D imaging, are entirely associated with museum specimens.
  2. We present a rapid, simple, accurate, and inexpensive morphometric method targeting thousands of free-ranging insects attracted to light screens using images taken without collecting a specimen or even constraining the individual in any manner. A reference grid printed on the screen is used to calibrate the images for shape and size without prior knowledge of the camera-subject configuration. The method requires only inexpensive, off-the-shelf, consumer equipment, and freely available programming (R statistical language) and image processing (ImageMagick) tools.
  3. We demonstrate the efficacy of the method using a dataset of 3675 images of free-ranging hawkmoths (Lepidoptera:Sphingidae) imaged in natural repose on a screen. We show that this method introduces no bias and has a high degree of correspondence with traditional morphometry using collected specimens. We also propose error metrics, which quantify the calibration quality and identify images with poor data.
  4. Although this method is particularly suited for the hyperdiverse moth community, which dominates the dynamics of many terrestrial ecosystems, it can be used for other phototropic taxa identifiable on an image to (morpho)-species. It will help in accumulating reliable trait data from hundreds of thousands of individual insects without any expenditure on specimen collection. It is particularly suited for studies which require multi-epoch, multi-locate sampling like investigations into ecosystem stability, climate change, and community assembly.
  相似文献   

13.
The usefulness of the 3D Portable Document Format (PDF) for clinical, educational, and research purposes has recently been shown. However, the lack of a simple tool for converting biomedical data into the model data in the necessary Universal 3D (U3D) file format is a drawback for the broad acceptance of this new technology. A new module for the image processing and rapid prototyping framework MeVisLab does not only provide a platform-independent possibility to create surface meshes out of biomedical/DICOM and other data and to export them into U3D – it also lets the user add meta data to these meshes to predefine colors and names that can be processed by a PDF authoring software while generating 3D PDF files. Furthermore, the source code of the respective module is available and well documented so that it can easily be modified for own purposes.  相似文献   

14.
X-rays and CT have been used to examine specimens such as human remains, mummies and formalin-fixed specimens. However, CT has not been used to study formalin-fixed wet specimens within their containers. The purpose of our study is firstly to demonstrate the role of CT as a non-destructive imaging method for the study of wet pathological specimens and secondly to use the CT data as a method for teaching pathological and radiological correlation. CT scanning of 31 musculoskeletal specimens from a pathology museum was carried out. Images were reconstructed using both soft-tissue and bone algorithms. Further processing of the data produced coronal and sagittal reformats of each specimen. The container and storage solution were manually removed using Volume Viewer Voxtool software to produce a 3D reconstruction of each specimen. Photographs of each specimen (container and close-up) were displayed alongside selected coronal, sagittal, 3D reconstructions and cine sequences in a specially designed computer program. CT is a non-destructive imaging modality for building didactic materials from wet specimens in a Pathology Museum, for teaching radiological and pathological correlation.  相似文献   

15.
A major part of histologic studies is the use of high resolution imaging for data collection and analysis. ImageJ, a freely available software from the NIH designed for image analysis, has many features that are not well-known among bone histologists and can be incredibly beneficial in terms of stream-lining data collection and maximizing limited resources. The aims of this technical note are twofold: (a) to describe methods for image annotation and measurement using region of interest overlays in ImageJ, and (b) to present a new code for a semi-automated method of measuring cortical bone areas from high resolution cross-sectional images also using ImageJ.  相似文献   

16.
Soft x-ray tomography (SXT) is increasingly being recognized as a valuable method for visualizing and quantifying the ultrastructure of cryopreserved cells. Here, we describe the combination of SXT with cryogenic confocal fluorescence tomography (CFT). This correlative approach allows the incorporation of molecular localization data, with isotropic precision, into high-resolution three-dimensional (3-D) SXT reconstructions of the cell. CFT data are acquired first using a cryogenically adapted confocal light microscope in which the specimen is coupled to a high numerical aperture objective lens by an immersion fluid. The specimen is then cryo-transferred to a soft x-ray microscope (SXM) for SXT data acquisition. Fiducial markers visible in both types of data act as common landmarks, enabling accurate coalignment of the two complementary tomographic reconstructions. We used this method to identify the inactive X chromosome (Xi) in female v-abl transformed thymic lymphoma cells by localizing enhanced green fluorescent protein-labeled macroH2A with CFT. The molecular localization data were used to guide segmentation of Xi in the SXT reconstructions, allowing characterization of the Xi topological arrangement in near-native state cells. Xi was seen to adopt a number of different topologies with no particular arrangement being dominant.  相似文献   

17.
Fluorescent confocal laser scanning microscopy allows an improved imaging of microscopic objects in three dimensions. However, the resolution along the axial direction is three times worse than the resolution in lateral directions. A method to overcome this axial limitation is tilting the object under the microscope, in a way that the direction of the optical axis points into different directions relative to the sample. A new technique for a simultaneous reconstruction from a number of such axial tomographic confocal data sets was developed and used for high resolution reconstruction of 3D-data both from experimental and virtual microscopic data sets. The reconstructed images have a highly improved 3D resolution, which is comparable to the lateral resolution of a single deconvolved data set. Axial tomographic imaging in combination with simultaneous data reconstruction also opens the possibility for a more precise quantification of 3D data. The color images of this publication can be accessed from http://www.esacp.org/acp/2000/20-1/heintzmann.++ +htm. At this web address an interactive 3D viewer is additionally provided for browsing the 3D data. This java applet displays three orthogonal slices of the data set which are dynamically updated by user mouse clicks or keystrokes.  相似文献   

18.
Soft x-ray tomography (SXT) is increasingly being recognized as a valuable method for visualizing and quantifying the ultrastructure of cryopreserved cells. Here, we describe the combination of SXT with cryogenic confocal fluorescence tomography (CFT). This correlative approach allows the incorporation of molecular localization data, with isotropic precision, into high-resolution three-dimensional (3-D) SXT reconstructions of the cell. CFT data are acquired first using a cryogenically adapted confocal light microscope in which the specimen is coupled to a high numerical aperture objective lens by an immersion fluid. The specimen is then cryo-transferred to a soft x-ray microscope (SXM) for SXT data acquisition. Fiducial markers visible in both types of data act as common landmarks, enabling accurate coalignment of the two complementary tomographic reconstructions. We used this method to identify the inactive X chromosome (Xi) in female v-abl transformed thymic lymphoma cells by localizing enhanced green fluorescent protein-labeled macroH2A with CFT. The molecular localization data were used to guide segmentation of Xi in the SXT reconstructions, allowing characterization of the Xi topological arrangement in near-native state cells. Xi was seen to adopt a number of different topologies with no particular arrangement being dominant.  相似文献   

19.
Tissue clearing and subsequent imaging of transparent organs is a powerful method to analyze fluorescently labeled cells and molecules in 3D, in intact organs. Unlike traditional histological methods, where the tissue of interest is sectioned for fluorescent imaging, 3D imaging of cleared tissue allows examination of labeled cells and molecules in the entire specimen. To this end, optically opaque tissues should be rendered transparent by matching the refractory indices throughout the tissue. Subsequently, the tissue can be imaged at once using laser-scanning microscopes to obtain a complete high-resolution 3D image of the specimen. A growing list of tissue clearing protocols including 3DISCO, CLARITY, Sca/e, ClearT2, and SeeDB provide new ways for researchers to image their tissue of interest as a whole. Among them, 3DISCO is a highly reproducible and straightforward method, which can clear different types of tissues and can be utilized with various microscopy techniques. This protocol describes this straightforward procedure and presents its various applications. It also discusses the limitations and possible difficulties and how to overcome them.  相似文献   

20.
Phenotypic assays are crucial in genetics; however, traditional methods that rely on human observation are unsuitable for quantitative, large-scale experiments. Furthermore, there is an increasing need for comprehensive analyses of multiple phenotypes to provide multidimensional information. Here we developed an automated, high-throughput computer imaging system for quantifying multiple Caenorhabditis elegans phenotypes. Our imaging system is composed of a microscope equipped with a digital camera and a motorized stage connected to a computer running the QuantWorm software package. Currently, the software package contains one data acquisition module and four image analysis programs: WormLifespan, WormLocomotion, WormLength, and WormEgg. The data acquisition module collects images and videos. The WormLifespan software counts the number of moving worms by using two time-lapse images; the WormLocomotion software computes the velocity of moving worms; the WormLength software measures worm body size; and the WormEgg software counts the number of eggs. To evaluate the performance of our software, we compared the results of our software with manual measurements. We then demonstrated the application of the QuantWorm software in a drug assay and a genetic assay. Overall, the QuantWorm software provided accurate measurements at a high speed. Software source code, executable programs, and sample images are available at www.quantworm.org. Our software package has several advantages over current imaging systems for C. elegans. It is an all-in-one package for quantifying multiple phenotypes. The QuantWorm software is written in Java and its source code is freely available, so it does not require use of commercial software or libraries. It can be run on multiple platforms and easily customized to cope with new methods and requirements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号