1.
An isocratic high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantification of clozapine (8-chloro-11-(4′-methyl)piperazino-5H-dibenzo[b,e]-1,4-diazepine) and its two major metabolites in plasma and red blood cells (RBCs). The method involves sample clean-up by liquid-liquid extraction with ethyl acetate. The organic phase was back-extracted with 0.1 M hydrochloric acid. Loxapine served as the internal standard. The analytes were separated by HPLC on a Kromasil Ultrabas C18 analytical column (5 μm particle size; 250×4.6 mm I.D.) using acetonitrile-phosphate buffer pH 7.0 (48:52, v/v) as eluent and were measured by UV absorbance detection at 254 nm. The limits of quantification were 20 ng/ml for clozapine and N-desmethylclozapine and 30 ng/ml for clozapine N-oxide. Recovery from plasma or RBCs proved to be higher than 62%. Precision, expressed as % C.V., was in the range 0.6–15%. Accuracy ranged from 96 to 105%. The method's ability to quantify clozapine and two major metabolites simultaneously with precision, accuracy and sensitivity makes it useful in therapeutic drug monitoring.  相似文献   

2.
Clozapine and its two major metabolites, N-desmethylclozapine and clozapine N-oxide were quantified using a high-performance liquid chromatographic method with UV detection in dog plasma following a single dose of clozapine. The analysis was performed on a 5-micrometer Hypersil CN (CPS-1; 250x4.6 mm) column. The mobile phase consisted of acetonitrile-water-1 M ammonium acetate (50:49:1, v/v/v), which was adjusted to pH 5.0 with acetic acid. The detection wavelength was 254 nm. A liquid-liquid extraction technique was used to extract clozapine and its metabolites from dog plasma. The recovery rates for clozapine, N-desmethylclozapine, and the internal standard (I.S.) were close to 100% using this method. The recovery rate for clozapine N-oxide (62-66%) was lower as expected because it is more polar. The quantitation limits for clozapine, clozapine N-oxide, and N-desmethylclozapine were 0.11, 0.05 and 0.05 microM, respectively. Intra-day reproducibility for concentrations of 0.1, 1.0 and 5.0 microM were 10.0, 4.4 and 4.2%, respectively, for N-oxide; 11.2, 4.3 and 4.9%, respectively, for N-desmethylclozapine; and 10.8, 2.2 and 4.9%, respectively, for clozapine. Inter-day reproducibility was <15% for clozapine N-oxide, <8% for N-desmethylclozapine and <19% for clozapine. This simple method was applied to determine the plasma concentration profiles of clozapine, N-desmethylclozapine and clozapine N-oxide in dog following administration of a 10 mg/kg oral dose of clozapine.  相似文献   

3.
A single solvent extraction step high-performance liquid chromatographic method is described for quantitating clozapine and its metabolite, N-desmethylclozapine, in rat serum microsamples (50 μl). The separation used a 2.1-mm I.D. reversed-phase Symmetry C18 column with an isocratic mobile phase consisting of methanol–acetonitrile–28.6 mM sodium acetate buffer, pH 2.6 (10:20:70, v/v/v). The detection limit was 2.5 ng/ml for all the compounds using an ultraviolet detector operated at 230 nm. The method was used to study the pharmacokinetics of clozapine after an intravenous bolus dose (2.5 mg/kg).  相似文献   

4.
A simultaneous assay for moricizine, its two sulphoxidation metabolites, morizine sulphoxide and moricizine sulphone, using high-performance liquid chromatography (HPLC) is described. The drug and metabolites and clozapine (internal standard) in biological fluids were extracted using pentanesulphonic acid into diethyl ether. The ethereal extract was evaporated to dryness and the residue was redissolved in the mobile phase (methanol-water-triethylamine, 65:35:0.5, v/v). The analyses were performed on a μBondapak reversed-phase C18 column housed in a Waters Z-module, linked to a C18 pre-column, with a run-time of 12 min. The retention times were 2.7, 3.5, 6.2 and 9.7 min for moricizine sulphone, moricizine sulphoxide, moricizine and clozapine, respectively. The recovery of the compounds from plasma ranged from 89.9% for the sulphoxide to 98.1% for clozapine. The limits of detection of the assay for moricizine, moricizine sulphoxide and moricizine sulphone were 20, 10 and 5 ng/ml, respectively.  相似文献   

5.
An isocratic high-performance liquid chromatography (HPLC) method with ultraviolet detection for the simultaneous determination of clozapine and its two major metabolites in human plasma is described. Analytes are concentrated from alkaline plasma by liquid–liquid extraction with n-hexane–isoamyl alcohol (75:25, v/v). The organic phase is back-extracted with 150 μl of 0.1 M dibasic phosphate (pH 2.2 with 25% H3PO4). Triprolidine is used as internal standard. For the chromatographic separation the mobile phase consisted of acetonitrile–0.06 M phosphate buffer, pH 2.7 with 25% phosphoric acid (48:52, v/v). Analytes are eluted at a flow-rate of 1.0 ml/min, separated on a 250×4.60 mm I.D. analytical column packed with 5 μm C6 silica particles, and measured by UV absorbance detection at 254 nm. The separation requires 7 min. Calibration curves for the three analytes are linear within the clinical concentration range. Mean recoveries were 92.7% for clozapine, 82.0% for desmethylclozapine and 70.4% for clozapine N-oxide. C.V. values for intra- and inter-day variabilities were ≤13.8% at concentrations between 50 and 1000 ng/ml. Accuracy, expressed as percentage error, ranged from −19.8 to 2.8%. The method was specific and sensitive with quantitation limits of 2 ng/ml for both clozapine and desmethylclozapine and 5 ng/ml for clozapine N-oxide. Among various psychotropic drugs and their metabolites, only 2-hydroxydesipramine caused significant interference. The method is applicable to pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

6.
A HPLC method with UV detection has been developed for the simultaneous determination of levomepromazine, clozapine and their main metabolites: N-desmethyl-levomepromazine, levomepromazine sulphoxide, O-desmethyl-levomepromazine, N-desmethylclozapine and clozapine N-oxide. The analytes were separated on a C8 reversed-phase column using a mobile phase composed of acetonitrile and a pH 2.0, 34 mM phosphate buffer containing 0.3% triethylamine (29:71, v/v). Loxapine was used as the internal standard. A reliable biological sample pre-treatment procedure by means of solid-phase extraction on C1 cartridges was implemented, which allows to obtain good extraction yields (>91%) for all analytes and appropriate sample purification from endogenous interference. The method was validated in terms of extraction yield, precision and accuracy. These assays gave RSD% values for precision always lower than 4.9% and mean accuracy values higher than 92%. The method is suitable for the therapeutic drug monitoring (TDM) of patients undergoing polypharmacy with levomepromazine and clozapine.  相似文献   

7.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed and validated for the measurement of (−)-2′-deoxy-3′-thiacytidine (3TC) in human serum. The method included precipitation of serum proteins by trichloroacetic acid (20%, w/v) treatment followed by centrifugation. The resulting supernatant was directly injected and 3TC was isocratically chromatographed on a reversed-phase C18 column using a mixture of phosphate buffer and methanol (88.3:11.7, v/v) and monitored at 280 nm. The limit of quantitation was 20 ng/ml using 100 μl of serum. The standard curve was linear within the range of 20–10 000 ng/ml. Replicate analysis of three quality control samples (40–1500 ng/ml) led to satisfactory intra- and itner-assay precision (coefficient of variation from 3.0 to 12.9%) and accuracy (deviation from −6.3 to 9.7%). Moreover, sample treatment processes including human immunodeficiency virus (HIV) heat-inactivation, exposure at room temperature and freezing-thawing cycles did not influence the stability of the analyte. This assay was successfully applied to the determination of 3TC serum levels in HIV-infected patients. In addition, preliminary results indicated that this procedure may also be extended to the measurement of 3TC in human plasma and urine.  相似文献   

8.
A high-performance liquid chromatographic screening method (HPLC) is described for the determination of seven selective serotonin reuptake inhibitors (SSRIs) (fluvoxamine, milnacipran, paroxetine, sertraline, fluoxetine, citalopram, venlafaxine) and for three pharmacologically active N-demethylated metabolites (desmethylcitalopram, didesmethylcitalopram and norfluoxetine). A tricyclic antidepressant, clomipramine, was used as an internal standard. The method consists of liquid extraction of serum after alcalinisation at pH 9.50, followed by chromatography on a Beckman C18 reversed-phase column. Compounds were detected at 200.4 nm. The standard curves were linear over a working range of 50–1000 ng/ml for fluvoxamine, 15–1000 ng/ml for fluoxetine, 25–500 ng/ml for norfluoxetine, 50–500 ng/ml for sertraline, 20–500 ng/ml for paroxetine, 25–550 ng/ml for citalopram, 25–750 ng/ml for desmethylcitalopram, 25–800 ng/ml for didesmethylcitalopram, 25–650 ng/ml for milnacipran, and 25–500 ng/ml for venlafaxine. The quantitation limits of the method were 15 ng/ml for fluoxetine, 20 ng/ml for paroxetine, 25 ng/ml for venlafaxine, norfluoxetine and citalopram, and its metabolites, 40 ng/ml for sertraline and 50 ng/ml for fluvoxamine. No interferences were noted with this sensitive and specific method which can be used for therapeutic drug monitoring.  相似文献   

9.
A simple and reliable method for analyzing the concentrations of clozapine and its biologically active metabolite, norclozapine, in human serum or plasma has been developed. This method is based on reversed-phase high-performance liquid chromatography (HPLC) with automated solid-phase extraction (SPE). For HPLC analysis, samples and standards are prepared with an ASPEC automatic sample preparator using 100 mg Bond-Elut C18 SPE columns. The HPLC assay is an isocratic method with a mobile phase of acetonitrile-methanol-10 mM dipotassium hydrogenphosphate, pH 3.7 (30:2:100, v/v/v) at a flow-rate of 1.5 ml/min with a C18 reversed-phase column. Detection is performed with a diode array detector set at 220 nm and with peak purity analyses at 210–365 nm. The absolute recovery varied from 85 and 95%. The intra-assay coefficients of variation (C.V.s) were from 4.2 and 8.0% and the inter-assay C.V.s were from 1.1. to 9.3% at therapeutic drug concentrations. The detection limit is 15 nmol/l. The method has been developed for use in a clinical laboratory for therapeutic drug monitoring.  相似文献   

10.
This paper describes a relatively simple and sensitive high-performance liquid chromatographic assay (HPLC) with ultraviolet absorbance detection for 5-fluorouracil (5-FUra) and its two main metabolites, 5-fluorouridine (5-FUrd) and 5-fluoro-2′-deoxyuridine (5-FdUrd), in plasma. In this study, two plasma clean-up procedures involving addition of internal standard, solid-phase and liquid-liquid extractions have been developed. A reversed-phase Kromasil C18 column was used. The detection was performed at 268 nm for 5-FUra and at 275 nm for the two metabolites. Linear detection responses were obtained for concentrations ranging from 25 to 1000 ng/ml. The average recovery from plasma was 35, 42 and 48% for 5-FUra, 5-FUrd and 5-FdUrd, respectively. Precision, expressed as C.V., ranged from 2.7 to 13% and the mean recovery from 94 to 105%. The limits of quantitation and detection of the three analytes were 20 and 10 ng/ml, respectively. The method was used to monitor the pharmacokinetic profile of 5-FUra and its two metabolites in patients with metastatic colorectal cancer.  相似文献   

11.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

12.
A sensitive and specific high-performance liquid chromatographic (HPLC) method with UV detection was developed for the determination of minocycline in human plasma and parotid saliva samples. Samples were extracted using an Oasis™ HLB cartridge and were injected into a C8 Nucleosil column. The HPLC eluent contained acetonitrile–methanol–distilled water–0.1% trifluoroacetic acid (25:2:72.9:0.1, v/v). Demeclocycline was used as internal standard. The assay showed linearity in the tested range of 0.1–25 μg/ml. The limit of quantitation was 100 ng/ml. Recovery from plasma or parotid saliva averaged 95%. Precision expressed as %CV was in the range 0.2–17% (limit of quantitation). Accuracy ranged from 93 to 111%. In the two matrices studied at 20 and 4°C, rapid degradation of the drug occurred. Frozen at −30°C, this drug was stable for at least 2 months, the percent recovery averaged 90%. The method’s ability to quantify minocycline with precision, accuracy and sensitivity makes it useful in pharmacokinetic studies.  相似文献   

13.
An optimized method for the determination of flecainide in serum is presented. Extraction using a solid-phase C18 column and chromatography on a stabilized fluorocarbon-bonded silica gel column effectively separate flecainide from an internal standard (a positional isomer of flecainide). The HPLC apparatus and conditions were as follows: analytical column, Fluofix 120N; sample solvent, 20 μl; column temperature, 40°C; detector, Shimadzu RF-5000 fluorescence spectrophotometer (excitation wavelength=300 nm, emission wavelength=370 nm); mobile phase, 0.06% phosphoric acid containing 0.1% tetra-n-butyl ammonium bromide–acetonitrile (75:25, v/v); flow-rate, 1.0 ml/min. The standard curves for flecainide were linear in the concentration range examined (10–2000 ng/ml). The regression equation was y=0.08+0.0078x (r=0.9998). The minimum detectable amount of flecainide was approximately 5 ng/ml. In the within-day study, the precision coefficients of variation were 2.66, 2.18, 2.54, 2.72, 2.88, 2.24, and 3.29% for the 10, 50, 100, 200, 500, 1000, and 1500 ng/ml standards, respectively. The absolute recovery rates of flecainide at each concentrations were 94–100%. The method described provides analytical sensitivity, specificity and reproducibility suitable for both biomedical research and therapeutic drug monitoring.  相似文献   

14.
Tamoxifen (TAM) is a triphenylethylene anti-oestrogen, commonly used in the treatment of breast cancer. Patients receiving tamoxifen therapy may experience both de novo and acquired resistance. As one of the mechanisms for this may be extensive peripheral bio-transformation of tamoxifen, there has been considerable interest in the pharmacokinetics and metabolism of tamoxifen. A reversed-phase high-performance liquid chromatography separation has been developed to determine the levels of tamoxifen and its major metabolites in human plasma. The method is highly sensitive (2 ng/ml) and selective for tamoxifen, cis-tamoxifen (CIS), 4-hydroxytamoxifen (4-OH) and desmethyltamoxifen (DMT). A μBondapak C18 10 μm column (30 cm × 3.9 mm I.D.) was used, with a mobile phase of methanol-1% triethylamine at pH 8 (89:11, v/v). Sample preparation was carried out using a C2 (500 mg sorbent, 3 ml reservoirs) solid phase extraction method, and extraction efficiencies were approximately 60% for TAM and its metabolites. Accuracy and precision, as determined by spiking plasma samples with a mixture of tamoxifen and its metabolites, ranged from 85–110% (± 5–10%) at 1 μg/ml, 101–118% (± 8–20%) at 0.1 μg/ml and 111–168% (± 43–63%) at 0.01 μg/ml. Results from 59 patients show mean values of 54 ng/ml for 4-OH; 190 ng/ml for DMT; 93 ng/ml for TAM and 30 ng/ml for CIS (detected in three patients only). This methodology can be applied routinely to the determination of TAM and its metabolites in plasma from patients undergoing therapy.  相似文献   

15.
Zolmitriptan, N-desmethylzolmitriptan, zolmitriptan N-oxide and an internal standard (an analogue of zolmitriptan) were extracted from plasma by a solid-phase extraction (SPE). Chromatography was performed using isocratic reversed-phase high-performance liquid chromatography (HPLC) with coulometric end-point detection. The standard curves were linear over the range 2-20 ng/ml for zolmitriptan and its metabolites in plasma. The mean inter- and intra-assay coefficients of variation over the range of the standard curves were less than 11%. The absolute recovery averaged 87, 58 and 77% for zolmitriptan. N-desmethylzolmitriptan and zolmitriptan N-oxide, respectively. The assay sensitivity was 0.5 ng for each analyte.  相似文献   

16.
An automated HPLC method with column switching is described for the determination of quetiapine, clozapine, perazine, olanzapine and metabolites in blood serum. After clean-up on silica C8 material (20 microm particle size) drugs were separated on ODS Hypersil C18 material (5 microm; column size 250 mm x 4.6 mm i.d.) within 25 min and quantified by ultraviolet (UV) detection at 254 nm. The limit of quantification ranged between 10 and 50 ng/ml. At therapeutic concentrations of the drugs, the inter-assay reproducibility was below 10%. Analyses of drug concentrations in serum of 75-295 patients treated with therapeutic doses of the antipsychotic drugs revealed mean+/-S.D. steady state concentrations of 139+/-136 ng/ml for quetiapine, 328+/-195 ng/ml for clozapine, 48+/-27 ng/ml for olanzapine and 71+/-52 ng/ml for perazine. The method was thus suitable for routine therapeutic drug monitoring and may be extended to other drugs.  相似文献   

17.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

18.
A simple procedure for the simultaneous determination of modafinil, its acid and sulfone metabolites in plasma is described. The assay involved an extraction of the drug, metabolites and internal standard from plasma with a solid-phase extraction using C18 cartridges. These compounds were eluted by methanol. The extract was evaporated to dryness at 40°C under a gentle stream of nitrogen. The residue was redissolved in 250 μl of mobile-phase and a 30 μl aliquot was injected via an automatic sampler into the liquid chromatograph and eluted with the mobile-phase (26%, v/v acetonitrile in 0.05 M orthophosphoric acid buffer adjusted to pH 2.6) at a flow-rate of 1.1 ml/min on a C8 Symmetry cartridge column (5 μm, 150 mm×3.9 mm, Waters) at 25°C. The eluate was detected at 225 nm. Intra-day coefficients of variation ranged from 1.0 to 2.9% and inter-day coefficients from 0.9 to 6.1%. The limits of detection and quantitation of the assay were 0.01 μg/ml and 0.10 μg/ml respectively.  相似文献   

19.
The simultaneous isolation and determination of mitoxantrone (Novantrone ®) and its two known metabolites (the mono- and dicarboxylic metabolites) were carried out using a high-performance liquid chromatographic (HPLC) system equipped with an automatic pre-column-switching system that permits drug analysis by direct injection of biological samples. Plasma or urine samples were injected directly on to an enrichment pre-column flushed with methanol-water (5:95, v/v) as the mobile phase. The maximum amount of endogenous water-soluble components was removed from biological samples within 9 min. Drugs specifically adsorbed on the pre-column were back-flushed on to an analytical column (Nucleosil C18, 250x4.6 mm I.D.) with 1.6 M ammonium formate buffer (pH 4.0) (2.5% formic acid) containing 20% acetonitrile. Detection was effected at 655 nm. Chromatographic analysis was performed within 12 min. The detection limit of the method was about 4 ng/ml for urine and 10 ng/ml for plasma samples. The precision ranged from 3 to 11% depending on the amount of compound studied. This technique was applied to the monitoring of mitoxantrone in plasma and to the quantification of the unchanged compound and its two metabolites in urine from patients receiving 14 mg/m2 of mitoxantrone by intravenous infusion for 10 min.  相似文献   

20.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   