1.
A new advanced glycation end product (AGE), N(omega)-carboxymethyl-arginine (CMA), was found in acid-soluble skin collagen of a newborn bovine prepared by in vitro glycation with 1 M glucose incubation at 37 degrees C for about 30 days [ 1 ]. CMA production was increased with incubation time in parallel, and after 30 days incubation the yield was 100 times higher than that of pentosidine [ 1 ]. This result suggested the importance of CMA as a major AGE in collagen. We have detected and measured the CMA level in human serum proteins by electrospray ionization/liquid chromatography/mass spectrometry (ESI/LC/MS), using CMA standard concentration curve. In this report, we first show the existence of CMA in vivo, and its serum level is significantly elevated in diabetic serum proteins, compared to age-matched control serum proteins. These results provide strong evidence that CMA is a new diagnostic marker of glycation in diabetes.  相似文献   

2.
C H Shackleton  C Kletke  S Wudy  J H Pratt 《Steroids》1990,55(10):472-478
A thermospray high-performance liquid chromatography/mass spectrometry method for determination of serum dehydroepiandrosterone sulfate is described. The steroid was measured intact using [7,7-2H2]dehydroepiandrosterone sulfate as internal standard. The analysis was carried out in the negative ion mode by determining the peak height ratio of the molecular anions of the analyte and internal standard. The method was used to determine the steroid in serum from 15 male and female normal adults and the following values were obtained: males, 272 +/- 45 micrograms/dl (range, 197 to 331 micrograms/dl) and females, 215 +/- 67 micrograms/dl (range, 107 to 347 micrograms/dl). In addition, dehydroepiandrosterone sulfate was measured by high-performance liquid chromatography/mass spectrometry and radioimmunoassay (a commercial kit) on 25 individuals of all age groups. There was strong correlation between the values obtained, but the radioimmunoassay values were generally double those obtained by high-performance liquid chromatography/mass spectrometry. Three other steroid sulfates, androsterone sulfate, epiandrosterone sulfate, and androst-5-ene-3 beta, 17 beta-diol sulfate, were also assayed. In males, these had mean values of 112, 44, and 13 micrograms/dl and, in females, they had mean values of 84, 25, and 6 micrograms/dl, respectively. Radioimmunoassay cross-reactivity measurement for these steroids (as reference compounds) showed that they were unlikely to contribute greatly to the discrepancy between radioimmunoassay and high-performance liquid chromatography/mass spectrometry values.  相似文献   

3.
The effects of glucose on insulin biosynthesis were studied by measuring the incorporation of radiolabelled amino acids into proinsulin/insulin in isolated rat islets. The islets were pulse labelled for 15 min with [3H]leucine (present in rat insulin I and II) or [35S]methionine (unique to rat insulin II) and then incubated for a 165 min post-label (chase) period during which the majority of labelled proinsulin was converted to insulin but under conditions whereby greater than 95% of radiolabelled proinsulin or insulin was retained in the islets. The newly synthesized, labelled, insulin was analyzed by high performance liquid chromatography. Rat I and II insulin biosynthesis was stimulated by 16.7 mM glucose to the same extent.  相似文献   

4.
Uric acid is an important diagnostic marker of catabolism of the purine nucleosides, and accurate measurements of serum uric acid are necessary for proper diagnosis of gout or renal disease appearance. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) has been described. An isotopically labeled internal standard, [1,3-(15)N(2)] uric acid, was added to serum, followed by equilibration and protein removal clean up to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) analyses. (M-H)(-) ions at m/z 167 and 169 for uric acid and its labeled internal standard were monitored for LC/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for uric acid (Standard Reference Materials SRM909b) with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added uric acid. The method performed well against the established reference method of ion-exchange followed by derivatization isotope dilution (ID) gas chromatography mass spectrometry (ID-GC/MS). The results of this method for uric acid agreed well with the certified values and were within 0.10%. The amounts of uric acid recovered and added were in good agreement for the three concentrations. This method was applied to determine uric acid in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.08-0.18% and between-set CVs of 0.02-0.07% for LC/MS analyses. Liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analysis was also performed. The LC/MS and LC/MS/MS results were in very good agreement (within 0.14%). This LC/MS method, which demonstrates good accuracy and precision, and is in the speed of analysis without the need for a derivatization stage, qualifies as a candidate reference method. This method can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared.  相似文献   

5.
To measure myoglobin, a marker for myocardial infarction, directly in human serum, two-dimensional liquid chromatography in combination with electrospray ionization mass spectrometry was applied as an analytical method. High-abundant serum proteins were depleted by strong anion-exchange chromatography. The myoglobin fraction was digested and injected onto a 60 mm x 0.2 mm i.d. monolithic capillary column for quantitation of selected peptides upon mass spectrometric detection. The addition of known amounts of myoglobin to the serum sample was utilized for calibration, and horse myoglobin was added as an internal standard to improve reproducibility. Calibration graphs were linear and facilitated the reproducible and accurate determination of the myoglobin amount present in serum. Manual data evaluation using integrated peak areas and an automated multistage algorithm fitting two-dimensional models of peptide elution profiles and isotope patterns to the mass spectrometric raw data were compared. When the automated method was applied, a myoglobin concentration of 460 pg/microL serum was determined with a maximum relative deviation from the theoretical value of 10.1% and a maximum relative standard deviation of 13.4%.  相似文献   

6.
High-performance liquid chromatography with electrospray mass spectrometry (LC–MS) was used for analysis of the drug flecainide in serum. The clean-up was performed by solid-phase extraction, and an aromatic ring positional isomer was used as internal standard. Results from method validation on spiked serum samples showed excellent reproducibility; intra- and inter-assay variations (C.V.% and %Bias) were less than 6% within the therapeutic concentration range of the drug (0.2–1.0 μg/ml). Linearity was demonstrated from 0.05 to 2.0 μg/ml. The limit of detection and quantification was 0.025 and 0.05 μg/ml, respectively. Due to the high selectivity of the mass spectrometric detection, no interferences were observed. Results from clinical samples (n=18) from patients in treatment with Tambocor (flecainide acetate) showed excellent correlation with parallel data obtained from a method based on high-performance liquid chromatography (HPLC) with fluorescence detection after liquid/liquid extraction. The chromatographic separation of flecainide and internal standard was improved compared to earlier HPLC methods. The methodology is simple, accurate and requires only 0.25 ml of sample. It is a well suited method for routine therapeutic drug monitoring in a hospital or clinical chemistry laboratory.  相似文献   

7.
A method has been developed for the blood level determination of the antihypertensive agent tiamenidine hydrochloride. The serum samples are mixed with deuterium labelled tiamenidine hydrochloride as an internal standard and extracted with methylene chloride. The extracts are derivatized with heptafluorobutyric acid anhydride and analysed by means of gas chromatography mass spectrometry using the selected ion monitoring technique to measure the molecular ion intensities of the bis-heptafluorobutyryl derivatives of tiamenidine hydrochloride and of the internal standard. Using 5 ml serum, the limit of detection is 0.2 ng ml-1 with an accuracy of +/- 0.17 ng (Syx of the calibration curve).  相似文献   

8.
Here we present evidence that a fibroblast heparan sulphate proteoglycan of approx. 300 kDa and with a core protein of apparent molecular mass 70 kDa is covalently linked to the plasma membranevia a linkage structure involving phosphatidylinositol. Phosphatidylinositol-specific phospholipase C releases such a heparan sulphate proteoglycan only from cells labelled with [35S]sulphate in the absence of serum. Cell cultures labelled with [3H]myo-inositol in the absence or presence of serum produce a radiolabelled heparan sulphate proteoglycan which was purified by gel-permeation chromatography and ion-exchange chromatography on MonoQ. Digestion with heparan sulphate lyase and analysis by gel-permeation chromatography and sodium dodecylsulphate-polyacrylamide gel-electrophoresis revealed that the3H-label is associated with a core protein of apparent mass 70 kDa.  相似文献   

9.
A liquid chromatographic-mass spectrometric (LC-MS) method with rapid automated sample preparation was developed and validated for determination of glybenclamide in human serum. Glybenclamide and its deuterated labelled internal standard were extracted from human serum samples by automated solid-phase extraction. The extract was injected into the LC-MS system for analysis. Glybenclamide and its internal standard were measured in multiple ion monitoring mode. The method was validated over a range of 10-1000 ng/ml with good accuracy and precision and was applicable for pharmacokinetic studies.  相似文献   

10.
Rabbit mammary fatty acid synthase was labelled in the acyl transferase domain(s) by the formation of the O-ester intermediates after incubation with [14C]acetyl- or malonyl-CoA. Elastase peptides containing the labelled acyl groups were isolated using high performance liquid chromatography and sequenced by fast atom bombardment mass spectrometry. An identical peptide (acyl-Ser---Leu---Gly---Glu---Val---Ala) was obtained after labelling with acetyl- or malonyl-CoA. This confirms the hypothesis that, unlike Escherichia coli or yeast, a single transferase catalyses the transfer of both acetyl- and malonyl-groups in the mammalian complex. The sequence at this site is compared with that around the active serine in other acyl transferases and hydrolases.  相似文献   

11.
Mild hyperhomocysteinemia has been established as a new independent risk factor for atherosclerosis and thrombosis. The metabolic syndrome of insulin resistance is associated with a high risk of coronary heart disease. Our objective was to determine if any relationship exists between the metabolic syndrome of insulin resistance in non-diabetic subjects and total serum homocysteine levels. Sixty-six healthy volunteers (33 males and 33 females) were selected from the population of Pilsen. Insulin resistance was measured by the Insulin Suppression Test using Octreotide. Steady-state plasma glucose concentrations at the end of the test period provided a quantitative measure of insulin resistance. Serum homocysteine level was estimated by high-pressure liquid chromatography. Serum folate and vitamin B12 were estimated using commercial kits on an Abbott IMx analyzer. All other laboratory tests were performed by standard methods in a routine biochemical laboratory. Subjects with the highest tertile of steady-state plasma glucose showed a significantly higher body mass index, blood pressure, fasting plasma triglyceride levels, plasminogen activator inhibitor-1 and lower HDL-cholesterol, i.e. an insulin resistance pattern. These subjects had significantly lower serum homocysteine levels compared with non-insulin resistant subjects. The negative association of insulin resistance and serum homocysteine was unexpected. The contribution of plasma folate levels to serum homocysteine levels and serum creatinine was significantly negative and positive, respectively.  相似文献   

12.
A high-pressure liquid chromatographic (hplc) procedure was developed for the determination of 25-hydroxycholecalciferol (25-OH-D3) in cow plasma or serum. The procedure involved extraction with an ethanol-ethyl ether mixture, separation of the aqueous phase, solvent partitions, column chromatography on silica gel, and, finally, determination by reversed phase hplc on a C18-bonded microparticulate silica column. The identity of the drug in the extract was confirmed by comparison with a standard by liquid, thin-layer, and gas-liquid chromatography as the free steroid and the heptafluorobutyrate and by the uv spectra and also from the mass spectrum of the heptafluorobutyrate. Twenty-four samples from cows on normal diet (dry, lactating, and pregnant) were analyzed. The normal circulating levels of 25-OH-D3 ranged from 40 to 58 ng/g; mean 48 ± 5.0 ng/g. The procedure was used to analyze a limited number of human and hog samples. Human serum contained 10–20 ng/g which was in agreement with literature values. Hog serum contained 18 ng/g.  相似文献   

13.
This report describes the use of FRIT fast atom bombardment (FAB) liquid chromatography/mass spectrometry for the analysis of acetylcholine in rat brain regions. Direct assessment of acetylcholine levels is possible without the need for either derivatization or extensive sample preparation. Quantification is accomplished by monitoring intact molecular cations of acetylcholine and a deuterated internal standard. The results are compared with those obtained by conventional pyrolysis gas chromatography/mass spectrometry and by liquid chromatography with electrochemical detection.  相似文献   

14.
In this study, we measured proinsulin in human pancreatic juice by radioimmunoassay (RIA). Affinity chromatography was used to separate proinsulin and insulin from C-peptide; and high-performance liquid chromatography, to separate proinsulin from insulin. In the RIA procedure for proinsulin we used porcine insulin antiserum as the antibody and porcine proinsulin as the standard and labelled antigen. The concentrations of proinsulin in human pancreatic juice obtained 5, 10, 15 and 20 minutes after intravenous injection of secretin were 29 +/- 6, 41 +/- 4, 35 +/- 14 and 37 +/- 17 (pmol/l +/- SD, means of 7 subjects), respectively. These values were higher than those in serum from fasted subjects, 12 +/- 4 pmol +/- SD. This work shows that proinsulin is present in human pancreatic juice.  相似文献   

15.
Reversed-phase liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) allows analysis of very complex peptide mixtures at great sensitivity, but it can be very time-consuming, typically using 60 min, or more, per sample analysis. We recently introduced the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation (~8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer for efficient analysis of peptide samples in proteomics research. The system performance of SPE-LC-MS/MS was evaluated in terms of sensitivity and efficiency for the analysis of tryptic peptide digests obtained from samples consisting of up to 12 standard proteins. The practical utility of the analytical setup was demonstrated by the analysis of <15 microg depleted human serum proteome by a combination of SDS-PAGE and SPE-LC-MS/MS. A total of 88 unique gene products spanning 3 orders of magnitude in serum protein concentration were identified using stringent database search criteria.  相似文献   

16.
Resveratrol is a natural polyphenol that exerts potent effects to suppress atherosclerosis. However, its low concentration in plasma has placed this role in doubt. Thus, resveratrol effects might be dependent on its transport into vascular endothelium, a question not previously addressed in spite of its obvious and fundamental importance. Via high-performance liquid chromatography and liquid chromatography/mass spectrometry, we found that resveratrol was absorbed by human umbilical vein endothelial cells in a temperature-, concentration- and time-dependent manner, suggesting the involvement of passive diffusion and active transport. As determined by confocal laser scanning microscopy, resveratrol primarily distributed throughout the cytoplasm. Furthermore, resveratrol absorption was modulated by serum proteins and sodium-dependent glucose transporter 1 (SGLT1) yet inhibited by glucose (an SGLT1 substrate) and phlorizin (an SGLT1 selective inhibitor), as well as SGLT1 siRNA transfection. Additionally, Sprague–Dawley rats were intragastrically administrated with 100 mg/kg of resveratrol and the concentration of resveratrol in blood vessels declined more slowly up to 24 h compared to that in the blood. Our results suggested that resveratrol uptake by vascular endothelial cells involved both passive diffusion and an SGLT1-mediated process, at least partially. Moreover, the intracellular resveratrol pool may be more important than the serum level in vivo. These provide new insights into the cardiovascular benefits of resveratrol.  相似文献   

17.
A highly sensitive radioimmunoassay for delta sleep-inducing peptide (DSIP) has been developed. A p-hydroxyphenylpropionic acid conjugate of DSIP was used for radioiodination. Using reversed-phase high performance liquid chromatography the labelled DSIP derivative was isolated in a high yield and with a high specific activity. The assay allows measurement of DSIP-like material in body fluids with a minimum detectable concentration of 0.1 ng/ml standard DSIP (10 pg/tube).  相似文献   

18.
DNA damage caused by lipid peroxidation products   总被引:5,自引:0,他引:5  
Lipid peroxidation is a process involving the oxidation of polyunsaturated fatty acids (PUFAs), which are basic components of biological membranes. Reactive electrophilic compounds are formed during lipid peroxidation, mainly alpha, beta-unsaturated aldehydes. These compounds yield a number of adducts with DNA. Among them, propeno and substituted propano adducts of deoxyguanosine with malondialdehyde (MDA), acrolein, crotonaldehyde and etheno adducts, resulting from the reactions of DNA bases with epoxy aldehydes, are a very important group of adducts. The epoxy aldehydes are more reactive towards DNA than the parent unsaturated aldehydes. The compounds resulting from lipid peroxidation mostly react with DNA showing both genotoxic and mutagenic action; among them, 4-hydroxynonenal is the most genotoxic, while MDA is the most mutagenic. DNA damage caused by the adducts of lipid peroxidation products with DNA can be removed by the repairing action of glycosylases. The formed adducts have been hitherto analyzed using the IPPA (Imunopurification-(32)P-postlabelling assay) method and via gas chromatography/electron capture negtive chemical ionization/mass spectrometry (GC/EC NCI/MS). A combination of liquid chromatography with electrospray tandem mass spectrometry (LC/ES-MSMS) with labelled inner standard has mainly been used in recent years.  相似文献   

19.
An analytical method was developed and validated to determine Formoterol in human serum in the range from 0.40 to 100.24 pg/mL by high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) due to the lack of efficient methods to determine very low levels of Formoterol in serum and plasma. Serum was diluted by water and mixed with the internal standard (d6-Formoterol). Formoterol and internal standard were extracted using a cation-exchange solid phase column (SCX-3). After eliminating endogenous serum constituents through washing steps with water and methanol, elution took place using methanol/ammonia. After evaporation of the elution liquid the residue was redissolved and analyzed by HPLC-MS/MS with electrospray ionisation (ESI) in positive mode. A gradient between 10 mM ammonium formate and acetonitrile was used. The inter-batch precision of the calibration standards ranged from 1.55% to 9.01%. The inter-batch accuracy of the calibration standards ranged from 93.37% to 107.30%. The lower limit of quantitation (LLOQ, 0.40 pg/mL) had a precision of 19.67% and an accuracy of 96.78%. Comparable results were obtained for quality control samples. Stability in human serum was given over three freeze/thaw cycles and 2h at room temperature. Formoterol in human serum was stable for at least 6 months below -20 degrees C. This method has been used widely for quantifying Formoterol after inhalation of 9-36 microg of the drug by volunteers. A cross validation with human plasma versus serum was performed after this method was successfully validated in human serum.  相似文献   

20.
A high throughput analytical method using a column switching high-performance liquid chromatography combined with isotope dilution tandem mass spectrometry (column switching-HPLC–MS/MS) was developed to simultaneously quantitate the concentrations of 7 perfluoroalkyl acids (PFAAs) in serum and 3 PFAAs in breast milk samples. The sample preparation includes addition of the isotope-labelled internal standard solution to breast milk and serum, enzymatic hydrolysis and filtration of milk samples, precipitation of proteins and analysis by column switching-HPLC–MS/MS. The limits of quantitation ranged from 0.1 to 0.4 μg/l for serum and 0.02 to 0.15 μg/l for breast milk samples. The method accuracies ranged between 73.2% and 100.2% for the different analytes at two concentrations in PFAAs spiked samples. The validity of the method was confirmed by analysing 20 serum and 20 breast milk samples.  相似文献   