首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Simultaneous determination of mycophenolic acid (MPA) and mycophenolic acid glucuronide (MPAG) in plasma was accomplished by isocratic HPLC with UV detection. After protein precipitation and phase separation with saturated sodium dihydrogenphosphate, chromatographic separation was achieved on a monolithic column "Chromolith Performance RP-18e", with acetonitrile/0.01 M phosphate buffer, pH 3, (25:75, v/v), as the mobile phase; flow rate 3.3 ml/min and measurement at 214 nm. Linearity was verified up to 40 mg/l for MPA and up to 400 mg/l for MPAG. Detection limits based on the analysis of 50 microl plasma were 0.05 and 0.5 mg/l for MPA and MPAG, respectively. Accuracy was 99.6-104% for MPA and 95.6-105% for MPAG and total imprecision (CV) was <7% for both compounds. Analytical recovery was >95% for MPA and MPAG. The method is simple, rapid, accurate and suitable for routine determination of MPA and MPAG in plasma.  相似文献   

2.
A method to determine total and free mycophenolic acid (MPA) and its metabolites, the phenolic (MPAG) and acyl (AcMPAG) glucuronides, using HPLC and mass spectrometry was developed. Mean recoveries in plasma and urine samples were >85%, and the lower limits of quantification for MPA, MPAG and AcMPAG were 0.05, 0.05 and 0.01 mg/L, respectively. For plasma, the assay was linear over 0.05-50 mg/L for MPA and MPAG, and from 0.01 to 10mg/L for AcMPAG. A validation study demonstrated good inter- and intra-day precision (CV相似文献   

3.
Two simple, sensitive and reproducible methods for determination of total mycophenolic acid (MPA) and its glucuronide metabolite (MPAG) as well as unbound MPA (fMPA) was developed by the use of HPLC-UV and LC-MS/MS methods, respectively. For the total MPA/MPAG method, the analytes were extracted using Isolute C(2) solid-phase extraction (SPE) cartridges and analyzed at 254 nm over a Zorbax Rx C(8) column (150 mm x 4.6 mm, 5 microm). The mobile phase was a gradient mixture of methanol and water (containing 0.1% (v/v) phosphoric acid). The total run time was 18 min and the extraction recovery was 77% for MPA and 84% for MPAG. The method was precise and accurate with a lower limit of quantification (LLOQ) of 0.5 mg/l for MPA and 5.0 mg/l for MPAG. For the fMPA method, plasma was subjected to ultrafiltration followed by SPE using C(18) cartridges. Analytical column was the same as the HPLC-UV method and the mobile phase was a gradient composition of methanol:0.05% formic acid with a flow rate of 0.6 ml/min for the first 3 min and 0.7 ml for the last 4 min. The chromatographic method separated MPA from its metabolites MPAG and Acyl-MPAG. Mass transitions in negative ionization mode for MPA and the internal standard, indomethacin were m/z: 319-->190.9 and m/z: 356-->312.2, respectively. The assay was linear in the concentration range of 1-1000 microg/l for fMPA with a LLOQ of 1 microg/l and an accuracy of >95%. The two methods reported have an adequate degree of robustness and dynamic concentration range for the measurement of MPA, MPAG and fMPA for therapeutic drug monitoring purposes or pharmacokinetics investigations.  相似文献   

4.
Simultaneous determination of mycophenolic acid (MPA) and mycophenolate phenol glucuronide (MPAG) in plasma and urine was accomplished by isocratic HPLC with UV detection. Plasma was simply deproteinated with acetonitrile and concentrated, whereas urine was diluted prior to analysis. Linearity was observed from 0.2 to 50 μg/ml for both MPA and MPAG in plasma and from 1 to 50 μg/ml of MPA and 5 to 2000 μg/ml MPAG in urine with extraction recovery from plasma greater than 70%. Detection limits using 0.25 ml plasma were 0.080 and 0.20 μg/ml for MPA and MPAG, respectively. The method is more rapid and simple than previous assays for MPA and MPAG in biological fluids from patients.  相似文献   

5.
An high performance liquid chromatography (HPLC)-UV method for the simultaneous determination of the free forms of mycophenolic acid (MPA) and its phenol glucuronide (MPAG) in human serum samples was developed for the first time. Chromatographic separation was performed on octadecylsilane based stationary phase in combination with a mobile phase of methanol/buffered tetrabutylammonium (TBA) salt mixture. Sample pretreatment consisted of an ultrafiltration step followed by clean-up/enrichment on a C(18) solid-phase extraction (SPE) cartridge. Average recoveries of (99.7 +/- 0.2)% and (64.1 +/- 6.9)% for free MPA and MPAG, respectively, were estimated in the concentration range from 0.5 to 10 microg/ml. The within-day and between-days coefficients of variation were 0.4 and 0.8% for free MPA (0.1 microg/ml spiking level) and 0.8 and 1.6% for free MPAG (5 microg/ml spiking level), respectively. The linear ranges for free MPA and MPAG were 0.06-1 and 0.2-10microg/ml, respectively. Detection limits of 4 and 17 ng/ml for free MPA and MPAG were estimated in spiked serum. The same HPLC method was also capable of a simultaneous determination of the total concentration of MPA and MPAG when coupled to a proper sample pretreatment step. The potential of the method is demonstrated by excretion kinetics measurement in serum of patients receiving MMF therapy.  相似文献   

6.
The immunosuppressant drug mycophenolic acid (MPA) and its major metabolite, mycophenolic acid glucuronide (MPAG), are highly bound to albumin. An HPLC-tandem-MS (HPLC/MS/MS) and an HPLC-UV assay were developed to measure free (unbound) concentrations of MPA and MPAG, respectively. Ultrafiltrate was prepared from plasma (500 microl) by ultrafiltration at 3000 x g for 20 min (20 degrees C). Both MPA and MPAG were isolated from ultrafiltrate (100 microl) by acidification and C18 solid-phase extraction. Free MPA was measured by electrospray tandem mass spectrometry using selected reactant monitoring (MPA: m/z 338.2--> 206.9) in positive ionisation mode. Chromatography was performed on a PFPP column (50 mm x 2 mm, 5 microm). Total analysis time was 7 min. The assay was linear over the range 1-200 microg/l with a limit of quantification of 1 microg/l. The inter-day accuracy and imprecision of quality controls (7.5, 40, 150 microg/l) were 94-99% and < 7%, respectively. Free MPAG was chromatographed on a C18 Nova-Pak column (150 mm x 3.9 mm, 5 microm) using a binary gradient over 20 min. The eluent was monitored at 254 nm. The assay was linear over the range 1-50 mg/l with the limit of quantification at 2.5 mg/l. The inter-day accuracy and imprecision of quality controls (5, 20, 45 mg/l) was 101-107% and < 8% (n = 4), respectively. For both methods no interfering substances were found in ultrafiltrate from patients not receiving MPA. The methods described have a suitable dynamic linear range to facilitate the investigation of free MPA and MPAG pharmacokinetics in transplant patients. Further, this is the first reported HPLC-UV method to determine free MPAG concentrations.  相似文献   

7.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of mycophenolic acid (MPA) and its glucuronide conjugate (MPAG) in human plasma. The method involves protein precipitation with acetonitrile, followed by ion-pair reversed-phase chromatography on C18 column, with a 40 mM tetrabutyl ammonium bromide (TBA)–acetonitrile (65:35, v/v) mobile phase. A 20-μl volume of clear supernatant was injected after centrifugation, and the eluent was monitored at 304 nm. No interference was found either with endogenous substances or with many concurrently used drugs, indicating a good selectivity for the procedure. Calibration curves were linear over a concentration range of 0.5–20.0 μg/ml for MPA and 5–200 μg/ml for MPAG. The accuracy of the method is good, that is, the relative error is below 5%. The intra- and inter-day reproducibility of the analytical method is adequate with relative statistical deviations of 6% or below. The limits of quantification for MPA and MPAG were lower than 0.5 and 5.0 μg/ml, respectively, using 50 μl of plasma. The method was used to determine the pharmacokinetic parameters of MPA and MPAG following oral administration in a patient with renal transplantation.  相似文献   

8.
A simple and sensitive HPLC method for the simultaneous analysis of free MPA and free MPAG was developed. Separation was achieved on a X-Terra RP18 column with acetonitrile-40 mM orthophosphoric acid as eluents using a gradient elution mode over 35 min at a flow rate of 1.5 ml/min. The assay was linear in the range 0.005 mg/L (LOQ) to 5mg/L for free MPA and 0.05 mg/L (LOQ) to 200 mg/L for free MPAG. Isolation of free MPA and free MPAG was done by ultrafiltration and the ultrafiltrate was directly injected. A positive correlation between MPA free fractions and free MPAG concentrations was found. Likewise, free MPAG was related to total MPAG concentrations in the seven heart transplant patients.  相似文献   

9.
A manual and an automated (Zymark PyTechnology robot) HPLC method for simultaneous determination of plasma mycophenolic acid (MPA) and its glucuronide conjugate (MPAG) are described here. Both methods are reproducible and accurate, and both are equivalent in all respects, including quantification limits (MPA, 0.100 μg/ml; MPAG, 4.00 μg/ml), range (using 0.05–0.5 ml of plasma: MPA, 0.0500–20.0 μg/aliquot; MPAG, 2.00–200 μg/aliquot), precision, and accuracy. MPA and MPAG were stable under the conditions used with both methods. Results from aliquots of paired control samples, analyzed by the manual method over three years at six analytical laboratories, showed excellent agreement in precision and accuracy.  相似文献   

10.
A micro method for determination of indomethacin in plasma was developed. Following deproteinization of plasma with acetonitrile containing internal standard (mefenamic acid), the separation of indomethacin and internal standard was achieved by high-performance liquid chromatography using a 7 μm LiChrosorb-RP18 column (250×4 mm I.D.) at 50°C. The mobile phase was 6 mM phosphoric acid–acetonitrile (50:50). The flow-rate was kept at 2.0 ml/min and the column effluent was monitored at 205 nm. The coefficients of variation of the method estimated at 0.2 and 1.0 μg/ml were 4.2 and 2.3%, and the detection limit of the drug was about 0.05 μg/ml (S/N=5). The method requires minimum pretreatment of the plasma with a small sample volume (25 μl), and is very suitable for therapeutic drug monitoring of indomethacin in premature infants with symptomatic patent ductus arteriosus.  相似文献   

11.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 microg/ml for iohexol and iothalamate, 5 to 40 microg/ml for PAH and 2.5 to 40 microg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.  相似文献   

12.
A simple, sensitive and reliable HPLC ion-pairing method with fluorescence detection, was developed for penciclovir determination in plasma and aqueous humor, with a Zorbax SB-aq C18 (100 mmx2.1 mm) column. Plasma samples were treated by solid-phase extraction with Oasis MCX (30 mg) cartridges. Ganciclovir, an antiviral drug structurally related to penciclovir, was used as internal standard (I.S.). Aqueous humor samples were directly injected into the chromatographic system. Separation was performed by a gradient elution with a mobile phase consisting of a mixture of acetonitrile and phosphate buffer 50mM containing 5mM of sodium octanesulfonate, pH 2.0, at a flow rate of 0.3 ml/min. The method was validated and showed good performances in terms of linearity, sensitivity, precision and trueness. Quantification limit was obtained at 0.05 microg/ml for aqueous humor and at 0.1 microg/ml for plasma. Finally, the proposed analytical method was used to measure penciclovir in clinical samples for a pharmacokinetic study, after oral administration of famciclovir.  相似文献   

13.
A GLP-validated, sensitive and specific LC-MS-MS method for the quantification of paclitaxel and its 6-alpha- and 3'-p-hydroxy metabolites is presented. A 0.400 ml plasma aliquot is spiked with a (13)C(6)-labeled paclitaxel internal standard and extracted with 1 ml methyl-tert.-butyl ether. The ether is evaporated and the residue is reconstituted in 130 microl of 30% aqueous acetonitrile (ACN) containing 0.1% trifluoroacetic acid. Isocratic HPLC analysis is performed by injecting 50 microl of the reconstituted material onto a 50x2.1 mm C(18) column with an ACN-water-acetic acid (50:50:0.1) mobile phase at 200 microl/min flow. Detection is by positive ion electrospray followed by multiple reaction monitoring of the following transitions: paclitaxel (854>509 u), 6-alpha-hydroxy paclitaxel (870>525 u), 3'-p-hydroxy paclitaxel (870>509 u) and internal standard (860>509 u). Quantification is by peak area ratio against the 13C(6) internal standard. The method range is 0.117-117 nM (0.1-100 ng/ml) for paclitaxel and both metabolites using a 0.400 ml human or dog plasma sample. Analysis time per sample is less than 5 min.  相似文献   

14.
An HPLC method was developed for the determination of a new oxazolidinone, DA-7867 (I), in human plasma and urine and in rat tissue homogenates. To 100 microl of biological sample, 300 microl acetonitrile and 50 microl methanol containing 10 microg/ml DA-7858 (the internal standard) were added. After vortex-mixing and centrifugation, the supernatant was evaporated under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of the mobile phase and a 50-microl aliquot was injected directly onto the reversed-phase (C(18)) column. The mobile phase, 20 mM KH2PO4:acetonitrile (75:25, v/v) was run at a flow rate of 1.5 ml/min and the column effluent was monitored by a UV detector set at 300 nm. The retention times of I and DA-7858 were approximately 6.5 and 8.7 min, respectively. The detection limits of I in human plasma and urine and in rat tissue homogenates were 20, 20, and 50 ng/ml, respectively.  相似文献   

15.
A method for the simultaneous direct determination of salicylate (SA), its labile, reactive metabolite, salicyl acyl glucuronide (SAG), and two other major metabolites, salicyluric acid and gentisic acid in plasma and urine is described. Isocratic reversed-phase high performance liquid chromatography (HPLC) employed a 15-cm C18 column using methanol-acetonitrile-25 mM acetic acid as the mobile phase, resulting in HPLC analysis time of less than 20 min. Ultraviolet detection at 310 nm permitted analysis of SAG in plasma, but did not provide sensitivity for measurement of salicyl phenol glucuronide. Plasma or urine samples are stabilized immediately upon collection by adjustment of pH to 3–4 to prevent degradation of the labile acyl glucuronide metabolite. Plasma is then deproteinated with acetonitrile, dried and reconstituted for injection, whereas urine samples are simply diluted prior to injection on HPLC. m-Hydroxybenzoic acid served as the internal standard. Recoveries from plasma were greater than 85% for all four compounds over a range of 0.2–20 μg/ml and linearity was observed from 0.1–200 μg/ml and 5–2000 μg/ml for SA in plasma and urine, respectively. The method was validated to 0.2 μg/ml, thus allowing accurate measurement of SA, and three major metabolites in plasma and urine of subjects and small animals administered salicylates. The method is unique by allowing quantitation of reactive SAG in plasma at levels well below 1% that of the parent compound, SA, as is observed in patients administered salicylates.  相似文献   

16.
An improved method suitable for the determination of 8-methoxypsoralen in the range 50–1500 ng/ml in the plasma of psoriatic patients undergoing PUVA (psoralens and long-wave ultraviolet light) therapy is proposed. A 5-ml aliquot of plasma containing sodium citrate as anticoagulant was centrifuged, griseofulvin was added as internal standard and the sample was denatured with acetonitrile. The supernatant was applied to C18 cartridges and 8-methoxypsoralen was eluted with methanol. The evaporated eluate was reconstituted in the mobile phase for high-performance liquid chromatography (HPLC) and applied to the HPLC column: mobile phase, acetonitrile—0.01 M phosphoric acid (34:66); flow-rate, 1 ml/min; temperature, 40°C; column, Spherisorb 5 ODS, 100 mm × 4.6 mm I.D., 5 μm particle size; UV detection at 248 nm; detection limit, 15 ng/ml of plasma.  相似文献   

17.
A simple and sensitive high-performance liquid chromatographic method was developed for the simultaneous determination of dihydromyricetin (1) and myricetin (2) in rat plasma after orally administrating the decoction of Ampelopsis grossedentata. Plasma samples were acidified with 0.375% phosphoric acid and extracted with ethyl acetate. Analysis of the extract was performed on reversed-phase C(18) column with a gradient eluent composed of acetonitrile and 0.04% phosphoric acid. The flow rate was kept at 1 ml/min and the detection wavelength was set at 290 and 370 nm for 1 and 2, respectively. The calibration curves were linear in the range of 0.247-4.114 microg/ml and 0.150-2.501 microg/ml for 1 and 2, respectively. The intra-day and inter-day precisions were better than 4.9 and 6.2%, respectively. The limits of detection (LOD) for 1 and 2 in plasma were 21.600 and 52.530 ng/ml, and the limits of quantification (LOQ) were 0.247 and 0.150 microg/ml, respectively. The mean recoveries for 1 and 2 were 92.0 and 93.3%, respectively. The accuracy and precision were well within the acceptable range and R.S.D. of measured rat samples was less than 7.5%. This validated method has been successfully applied in the pharmacokinetics study of dihydromyricetin and myricetin in vivo after orally administrating the decoction of A. grossedentata to rats.  相似文献   

18.
Mitoguazone is an antiproliferative agent used in chemotherapy. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of mitoguazone in 100 microl of plasma. Samples were deproteinized with 100 microl of a solution of internal standard (amiloride, 10 microg/ml) in acetonitrile. An aliquot of the supernatant was injected onto the column. HPLC separation was achieved on a silica column with the mobile phase of methanol-50 mM potassium phosphate buffer (pH 3)-triethylamine (80:20:0.3, v/v), at a flow-rate of 1 ml/min. The eluent was detected at 320 nm. The retention time was about 5.5 min for amiloride and 12 min for mitoguazone. No endogenous substances were found to interfere. Calibration curves were linear from 0.25 to 50 microg/ml. The absolute recoveries of mitoguazone and amiloride were both greater than 84%. The limit of quantitation was 0.25 microg/ml. The intra- and inter-day precision (expressed as RSD) was 5.8%, or less, and the accuracy was 94.7% of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring mitoguazone concentration.  相似文献   

19.
A simple and reproducible reversed-phase ion-pair high-performance liquid chromatographic (HPLC) method using isocratic elution with UV absorbance detection is presented for the simultaneous quantitation of mycophenolic acid (MPA) and MPA-glucuronide (MPAG) in human plasma and urine. The sample preparation procedures involved simple protein precipitation for plasma and 10-fold dilution for urine. Each analytical run was completed within 15min, with MPAG and MPA being eluted at 3.8 and 11.4min, respectively. The optimized method showed good performance in terms of specificity, linearity, detection and quantitation limits, precision and accuracy. This assay was demonstrated to be applicable for clinical pharmacokinetic studies.  相似文献   

20.
Lamotrigine is a broad-spectrum antiepileptic agent. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of lamotrigine in 50 microl of plasma. Lamotrigine and the internal standard guanabenz were extracted with 1.2 ml of diethyl ether, after the samples alkalinized with 10 microl of sodium hydroxide solution (1N). Chromatographic separation was achieved on a silica column with the mobile phase of acetonitrile-water containing 0.2% phosphoric acid and 0.3% triethylamine (pH 2.7) (84:16, v/v), at a flow-rate of 1 ml/min. The eluant was detected at 225 nm. The retention time was about 6 min for lamotrigine and 7 min for guanabenz. No endogenous substances and concomitant anticonvulsants were found to interfere. Calibration curves were linear from 0.1 to 5 microg/ml. The relative recovery of lamotrigine averaged about 80%. The limit of quantitation was 0.1 microg/ml. The intra- and inter-day precision (expressed as coefficient of variation, CV) was 8.1%, or less, and the accuracy was within 11.5% deviation of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring lamotrigine concentration.  相似文献   