首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Journal of biomechanics》2014,47(14):3524-3530
To investigate the hemodynamic performance of overlapping bare-metal stents intervention treatment to thoracic aortic aneurysms (TAA), three simplified TAA models, representing, no stent, with a single stent and 2 overlapped stents deployed in the aneurismal sac, were studied and compared in terms of flow velocity, wall shear stress (WSS) and pressure distributions by means of computational fluid dynamics. The results showed that overlapping stents intervention induced a flow field of slow velocity near the aneurismal wall. Single stent deployment in the sac reduced the jet-like flow formed prior to the proximal neck of the aneurysm, which impinged on the internal wall of the aneurysm. This jet-like flow vanished completely in the overlapping double stents case. Overlapping stents intervention led to an evident decrease in WSS; meanwhile, the pressure acting on the wall of the aneurysm was reduced slightly and presented more uniform distribution. The results therefore indicated that overlapping stents intervention may effectively isolate the thoracic aortic aneurysm, protecting it from rupture. In conclusion, overlapping bare-metal stents may serve a purpose similar to that of the multilayer aneurysm repair system (MARS) manufactured by Cardiatis SA (Isnes, Belgium).  相似文献   

2.
Previous research on the effects of intracranial stents on arterial hemodynamics has involved computational hemodynamics (CHD) simulations applied to artificially generated stent models. In this study, accurate geometric reconstructions of in-vitro (PTFE tube) and ex-vivo (canine artery) deployed stents based on ultra-high resolution MicroCT imaging were used. The primary goal was to compare the hemodynamic effects of deployment in these two different models and to identify flow perturbations due to deployment anomalies such as stent malapposition and strut prolapse, important adverse mechanics occurring in clinical practice, but not considered in studies using idealized stent models.Ultra-high resolution MicroCT data provided detailed visualization of deployment characteristics allowing for accurate in-stent flow simulation. For stent cells that are regularly and symmetrically deployed, the near wall flow velocities and wall shear stresses were similar to previously published results derived from idealized models. In-stent hemodynamics were significantly altered by misaligned or malapposed stent cells, important effects not realistically captured in previous models. This research shows the feasibility and value of an ex-vivo stent model for MicroCT based CHD studies. It validates previous in-vitro studies and further contributes to the understanding of in-stent hemodynamics associated with adverse mechanics of self-expanding intracranial stents.  相似文献   

3.
We investigated the flow modifications induced by a large panel of commercial-off-the-shelf (COTS) intracranial stents in an idealized sidewall intracranial aneurysm (IA). Flow velocities in IA silicone model were assessed with and without stent implantation using particle imaging velocimetry (PIV). The use of the recently developed multi-time-lag method has allowed for uniform and precise measurements of both high and low velocities at IA neck and dome, respectively. Flow modification analysis of both regular (RSs) and flow diverter stents (FDSs) was subsequently correlated with relevant geometrical stent parameters. Flow reduction was found to be highly sensitive to stent porosity variations for regular stents RSs and moderately sensitive for FDSs. Consequently, two distinct IA flow change trends, with velocity reductions up to 50% and 90%, were identified for high-porosity RS and low-porosity FDS, respectively. The intermediate porosity (88%) regular braided stent provided the limit at which the transition in flow change trend occurred with a flow reduction of 84%. This transition occurred with decreasing stent porosity, as the driving force in IA neck changed from shear stress to differential pressure. Therefore, these results suggest that stents with intermediate porosities could possibly provide similar flow change patterns to FDS, favourable to curative thrombogenesis in IAs.  相似文献   

4.
Sugihara-Seki M 《Biorheology》2000,37(5-6):341-359
To evaluate the fluid forces acting on cells adhered to a microvessel wall, we numerically studied the flow field around adherent cells and the distribution of the stresses on their surfaces. For simplicity, the cells were modeled as rigid particles attached to a wall of a circular cylindrical tube regularly in the flow direction, in a row or two rows. It was found that not the detailed shape of the model cells but their height from the vessel wall is a key determinant of the fluid forces and torque acting on them. In both arrangements of one row and two rows, the axial spacing between neighboring adherent cells significantly affects the distributions of the stresses on them, which results in drastic variations of the fluid forces with the axial spacing and the relative positions with respect to their neighboring cells. The drag force acting on an adherent cell in the vessel was evaluated to be larger than the value in the 2D chamber flow at the same wall shear stress, mainly due to much larger variations of the pressure distribution on the cell surface in the vessel flow.  相似文献   

5.
Endovascular stents are being commonly used to treat cerebral wide-necked aneurysms recently. The effect of a stent placed in the parent artery is not only to protect the parent artery from occlusion, due to extension of coils and thrombosis, but also to act as flow diverter to vary the haemodynamics in the aneurysm. In this article, two idealised cerebral wide-necked aneurysms were created, one was sidewall aneurysm with curved parent vessel and the other was terminal aneurysm with the bifurcated parent vessel. The plexiglass models of the two aneurysms were 'treated' with commercial porous intravascular stents. The stented physical models were scanned by Micro-CT and the numerical models of the two idealised cerebral wide-necked aneurysms after stent placement were constructed from the scanned image files. The pulsatile flow of non-Newtonian fluid inside the models was simulated by using computational fluid dynamics package. From the simulated flow dynamics, various haemodynamic characteristics such as velocity contours, wall shear stress and oscillatory shear index (OSI) were computed. The velocity of the jet entering the sacs reduced after stent was deployed across the necks of both sidewall and terminal aneurysms; the wall shear stress on the distal neck of sidewall aneurysm reduced, the wall shear stress on the dome of the terminal aneurysm increased and the OSI on the dome of the terminal aneurysm reduced. Therefore, stent placement not only promotes thrombus formation in both aneurysm models but also reduces the regrowth risk of the sidewall aneurysm and the rupture risk of the terminal aneurysm.  相似文献   

6.
There is still a considerable lack of quantitative information concerning the effects of stent structures on blood flow in an aneurismal cavity. In this paper, five virtual stents with different structures and wire cross-sections were designed for incorporation into the same patient-specific aneurysm model. Computational fluid dynamics simulations were performed so as to study how these five types of stents modified hemodynamic parameters. Numerical results demonstrated that the mean flow rate in the aneurismal cavity decreased the most in the model that used a stent with a rectangular wire cross-section, and that the wall shear stresses at the dome and neck of the aneurysm decreased more in models that used a stent with a circular wire cross-section or a spiral stent with a rectangular wire cross-section compared to other models. In addition, the wall pressure on the aneurysm increased slightly after implantation of the stent in all five models. This result differs from that previously published, and may help guide the design and assist clinicians in selecting an appropriate stent for treating cerebral aneurysms.  相似文献   

7.
Endovascular stents are being commonly used to treat cerebral wide-necked aneurysms recently. The effect of a stent placed in the parent artery is not only to protect the parent artery from occlusion, due to extension of coils and thrombosis, but also to act as flow diverter to vary the haemodynamics in the aneurysm. In this article, two idealised cerebral wide-necked aneurysms were created, one was sidewall aneurysm with curved parent vessel and the other was terminal aneurysm with the bifurcated parent vessel. The plexiglass models of the two aneurysms were ‘treated’ with commercial porous intravascular stents. The stented physical models were scanned by Micro-CT and the numerical models of the two idealised cerebral wide-necked aneurysms after stent placement were constructed from the scanned image files. The pulsatile flow of non-Newtonian fluid inside the models was simulated by using computational fluid dynamics package. From the simulated flow dynamics, various haemodynamic characteristics such as velocity contours, wall shear stress and oscillatory shear index (OSI) were computed. The velocity of the jet entering the sacs reduced after stent was deployed across the necks of both sidewall and terminal aneurysms; the wall shear stress on the distal neck of sidewall aneurysm reduced, the wall shear stress on the dome of the terminal aneurysm increased and the OSI on the dome of the terminal aneurysm reduced. Therefore, stent placement not only promotes thrombus formation in both aneurysm models but also reduces the regrowth risk of the sidewall aneurysm and the rupture risk of the terminal aneurysm.  相似文献   

8.
Drug-eluting stents (DES), which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours) or very slowly (over periods of several months up to one year) at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.  相似文献   

9.
BackgroundMultiple overlapping uncovered stents (MOUS) system has shown potentials in managing complex aortic aneurysms with side branches involvement. It promotes the development of thrombus by modulating local flow pattern that reduces the wall tension, while maintaining patency of side branches. However the modulation of local hemodynamic parameters depends on various factors that have not been assessed comprehensively.MethodsAneurysm 3D geometry was reconstructed based on CT images. One-way fluid-structure interaction analysis was performed to quantify structural stress concentration in the wall, and changes of blood velocity, wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT) and pressure in the sac due to the stent deployment.ResultsHigh structural stress concentration due to stent deployment was found in the landing zone and it increased linearly with the number of stents deployed. The wall tension in the sac was unaffected by the stent deployment. Stress within the wall was insensitive to the different overlapping pattern. After one stent was deployed, the mean flow velocity in the sac reduced by 36.4%. The deployment of the 2nd stent further reduced the mean sac velocity by 10%. WSS decreased while both OSI and RRT increased after stent deployment, however pressure in the sac remained nearly unchanged. Except for the cases with complete stents struts alignment, different overlapping pattern had little effect on flow parameters.ConclusionsMechanical parameters modulated by the MOUS are insensitive to different overlapping pattern suggesting that endovascular procedure can be performed with less attention to the overlapping pattern.  相似文献   

10.
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of WSS were determined using three-dimensional computational fluid dynamics. Vascular histology was unchanged proximal and distal to the stent. Time-dependent NH was localized within the stented region and was greatest in regions exposed to low WSS and acute elevations in spatial WSS gradients. The lowest values of WSS spatially localized to the stented area of a theoretical artery progressively increased after 14 and 21 days as NH occurred within these regions. This NH abolished spatial disparity in distributions of WSS. The results suggest that stents may introduce spatial alterations in WSS that modulate NH in vivo.  相似文献   

11.
This theoretical/numerical study aims at assessing the haemodynamic changes induced by endovascular stenting. By using the classical one-dimensional linear pressure waves theory in elastic vessels, we first show that the modulus of the reflection coefficient induced by an endovascular prosthesis is most likely small since it is proportional to the stent-to-wavelength ratio. As a direct consequence, the wall motion of the elastic (stented) artery can be prescribed a priori and the coupled fluid-structure problem does not have to be solved for assessing the haemodynamic changes due to stenting. Several 2D axisymetric calculations are performed to solve the unsteady incompressible Navier-Stokes equations on moving meshes for different types of (stented) arteries. The numerical results suggest that endovascular stenting increases the systo-diastolic variations of the wall shear stress (by 35% at the middle of the stent, by almost 50% in the proximal transition region). Additional calculations show that over-dilated stents produce less haemodynamic perturbations. Indeed, the increase of the amplitude of the wall shear stress variations over the cardiac cycle is only 10% when the stent radius is equal to the radius of the elastic artery at systole (instead of being equal to the mean artery radius).  相似文献   

12.
Shear rates measured at sites along the walls of ten casts of human aortic bifurcations are presented to provide an indication of the variability in the shear rate distribution that can occur among individuals. The geometric characteristics and flow parameters for each of the casts are also given. Much of the variability in wall shear distribution seen here results from variations in arterial geometry; variations in flow parameters can widen further the normal range of shear distributions.  相似文献   

13.
Our paper builds on existing research into conventional bare metal stents in order to assess new devices specifically designed for coronary bifurcation angioplasty. The first aim is to validate the numerical model against data from in vitro experiments on stented coronary phantoms. A surface mesh was built in accordance with micro-computed tomography images obtained from coronary stents implanted in silicone models and used for numerical analysis. Computational simulations for steady and unsteady cases generally agreed with their experimental counterparts. A second objective is to compare the hemodynamic performance of one of these new devices (Stentys) to that of conventional devices and stenting techniques in a simplified coronary bifurcation model. Four different coronary bifurcation stenting techniques were analyzed. We have focused on factors contributing to restenosis, such as wall shear stress (WSS), oscillatory shear index (OSI), pressure loss, and local normalized helicity (LNH). It was found that bifurcation-specific stents implanted in the side branch led to increased malapposition. This effect has proved to be more important than stent specific design characteristics such as strut size (different for conventional and Stentys stent). This conclusion is confirmed by means of drop in pressure and mechanical energy loss rate calculation; for the latter, the increase ranged from 9% to 17%, depending on the stenting technique, when dedicated stents were implanted in the side branch. The behavior patterns presented in this study should be double-checked against those obtained in more realistic geometries.  相似文献   

14.
Blood flow dynamics in saccular aneurysm models of the basilar artery   总被引:1,自引:0,他引:1  
Blood flow dynamics under physiologically realistic pulsatile conditions plays an important role in the growth, rupture, and surgical treatment of intracranial aneurysms. The temporal and spatial variations of wall pressure and wall shear stress in the aneurysm are hypothesized to be correlated with its continuous expansion and eventual rupture. In addition, the assessment of the velocity field in the aneurysm dome and neck is important for the correct placement of endovascular coils. This paper describes the flow dynamics in two representative models of a terminal aneurysm of the basilar artery under Newtonian and non-Newtonian fluid assumptions, and compares their hemodynamics with that of a healthy basilar artery. Virtual aneurysm models are investigated numerically, with geometric features defined by beta = 0 deg and beta = 23.2 deg, where beta is the tilt angle of the aneurysm dome with respect to the basilar artery. The intra-aneurysmal pulsatile flow shows complex ring vortex structures for beta = 0 deg and single recirculation regions for beta = 23.2 deg during both systole and diastole. The pressure and shear stress on the aneurysm wall exhibit large temporal and spatial variations for both models. When compared to a non-Newtonian fluid, the symmetric aneurysm model (beta = 0 deg) exhibits a more unstable Newtonian flow dynamics, although with a lower peak wall shear stress than the asymmetric model (beta = 23.2 deg). The non-Newtonian fluid assumption yields more stable flows than a Newtonian fluid, for the same inlet flow rate. Both fluid modeling assumptions, however, lead to asymmetric oscillatory flows inside the aneurysm dome.  相似文献   

15.
Pulsatile flow fields in a cerebrovascular side-wall aneurysm model with a wide ostium after stenting are presented in terms of particle tracking velocimetry measurements and flow visualization. Among the stent parameters the shape, helix versus mesh, was selected to study its effect on the changes of intraaneurysmal hemodynamics for the reference of minimally invasive endovascular aneurysm treatment. The blocking ratio of the stents was fixed at 30%. The Womersley number was 3.9 and the mean, peak, and minimal Reynolds numbers based on the bulk average velocity and diameter of the parent vessel were 600, 850, and 300, respectively. Four consecutive flow-rate phases were selected to characterize the intra-aneurysmal flow. The results are characterized in terms of velocity vector field, regional average velocity, and intra-aneurysmal vorticity/circulation/wall shear stress. It is found that the hemodynamic features inside the aneurysm alter markedly with the shape of the stent and the size of the orifice. Both stents investigated induce favorable changes in the intra-aneurysmal flow stasis as well as direction and undulation of wall shear stresses. A comparison of the results of the helix to mesh stent shows that the former is more favorable for endovascular treatment.  相似文献   

16.
The transport of macromolecules, such as low density lipoproteins (LDLs), across the artery wall and their accumulation in the wall is a key step in atherogenesis. Our objective was to model fluid flow within both the lumen and wall of a constricted, axisymmetric tube simulating a stenosed artery, and to then use this flow pattern to study LDL mass transport from the blood to the artery wall. Coupled analysis of lumenal blood flow and transmural fluid flow was achieved through the solution of Brinkman's model, which is an extension of the Navier-Stokes equations for porous media. This coupled approach offers advantages over traditional analyses of this problem, which have used possibly unrealistic boundary conditions at the blood-wall interface; instead, we prescribe a more natural pressure boundary condition at the adventitial vasa vasorum, and allow variations in wall permeability due to the occurrence of plaque. Numerical complications due to the convection dominated mass transport process (low LDL diffusivity) are handled by the streamline upwind/Petrov-Galerkin (SUPG) finite element method. This new fluid-plus-porous-wall method was implemented for conditions typical of LDL transport in a stenosed artery with a 75 percent area reduction (Peclet number=2 x 10(8)). The results show an elevated LDL concentration at the downstream side of the stenosis. For the higher Darcian wall permeability thought to occur in regions containing atheromatous lesions, this leads to an increased transendothelial LDL flux downstream of the stenosis. Increased transmural filtration in such regions, when coupled with a concentration-dependent endothelial permeability to LDL, could be an important contributor to LDL infiltration into the arterial wall. Experimental work is needed to confirm these results.  相似文献   

17.
Coronary artery stenosis is commonly treated by stent placement via percutaneous intervention, at times requiring multiple stents that may overlap. Stent overlap is associated with increased risk of adverse clinical outcome. While changes in local blood flow are suspected to play a role therein, hemodynamics in arteries with overlapping stents remain poorly understood. In this study we analyzed six cases of partially overlapping stents, placed ex vivo in porcine left coronary arteries and compared them to five cases with two non-overlapping stents. The stented vessel geometries were obtained by micro-computed tomography of corrosion casts. Flow and shear stress distribution were calculated using computational fluid dynamics. We observed a significant increase in the relative area exposed to low wall shear stress (WSS<0.5 Pa) in the overlapping stent segments compared both to areas without overlap in the same samples, as well as to non-overlapping stents. We further observed that the configuration of the overlapping stent struts relative to each other influenced the size of the low WSS area: positioning of the struts in the same axial location led to larger areas of low WSS compared to alternating struts. Our results indicate that the overlap geometry is by itself sufficient to cause unfavorable flow conditions that may worsen clinical outcome. While stent overlap cannot always be avoided, improved deployment strategies or stent designs could reduce the low WSS burden.  相似文献   

18.
Studies in adults have shown marked changes in geometry and relative positions of the carotid arteries when rotating the head. The aim of this study was to quantify the change in geometry and analyze its effect on carotid hemodynamics as a result of head rotation. The right carotid arteries of nine young adult subjects were investigated in supine position with straight and left turned head positions, respectively. The three-dimensional (3D) carotid geometry was reconstructed by using 3D ultrasound (3D US), and the carotid hemodynamics were calculated by combining 3D US with computational fluid dynamics. It was observed that cross-sectional areas and shapes did not change markedly with head rotation, but carotid vessel center lines altered with planarification of the common carotid artery as a main feature (P < 0.05). Measured common carotid flow rates changed significantly at the individual level when the head was turned, but on the average, the change in mean common carotid flow rate was relatively small (0.37 +/- 1.11 ml/s). The effect of the altered center lines and flow rates on the atherogenic nature of the carotid bifurcation was evaluated by using calculated hemodynamic wall parameters, such as wall shear stress (WSS) and oscillatory shear index (OSI). It was found that WSS and OSI patterns changed significantly with head rotation, but the variations were very subject dependent and could not have been predicted without assessing the altered geometry and flow of the carotid bifurcation for individual cases. This study suggests that there is a need for standardization of the choice of head position in the 3D US scan protocol, and that carotid stents and emboli diverters should be studied in different head positions.  相似文献   

19.
Vascular stents influence the post-procedural hemodynamic environment in ways that may encourage restenosis. Understanding how stents influence flow patterns may lead to more hemodynamically compatible stent designs that alleviate thrombus formation and promote endothelialization. This study employed time-resolved Digital Particle Image Velocimetry (DPIV) to compare the hemodynamic performance of two stents in a compliant vessel. The first stent was a rigid insert, representing an extreme compliance mismatch. The second stent was a commercially available nitinol stent with some flexural characteristics. DPIV showed that compliance mismatch promotes the formation of a ring vortex in the vicinity of the stent. Larger compliance mismatch increased both the size and residence time of the ring vortex, and introduced in-flow stagnation points. These results provide detailed quantitative evidence of the hemodynamic effect of stent mechanical properties. Better understanding of these characteristics will provide valuable information for modifying stent design in order to promote long-term patency.  相似文献   

20.
Clinical studies suggest that stent design and surface texture are responsible for differences in biocompatibility of metallic endovascular stents. A simple in vitro experimental setup was established to test stent-induced degree of platelet and leukocyte activation and platelet-leukocyte aggregation by flow cytometry. Heparin-coated tantalum stents and gold-coated and uncoated stainless steel stents were tested. Stents were implanted into silicone tubes and exposed to blood from healthy volunteers. Platelet and leukocyte activation and percentage of leukocyte-platelet aggregates were determined in a whole-blood assay by subsequent staining for activation-associated antigens (CD41a, CD42b, CD62p, and fibrinogen binding) and leukocyte antigens (CD14 and CD45) and flow cytometric analysis. Blood taken directly after venous puncture or exposed to the silicone tube alone was used as negative controls. Positive control was in vitro stimulation with thrombin receptor activating peptide (TRAP-6). Low degree of platelet activation and significant increase in monocyte- and neutrophil-platelet aggregation were observed in blood exposed to stents (P < 0.05). In addition, leukocyte activation was induced as measured by increased CD45 and CD14 expression. Heparin coated stents continuously induced less platelet activation and leukocyte-platelet aggregation than uncoated stainless steel stents of the same length and shorter stents of the same structure. Stent surface coating and texture plays a role in platelet and leukocyte activation and leukocyte-platelet aggregation. Using this simple in vitro assay and whole blood and flow cytometry, it seems possible to differentiate stents by their potency to activate platelets and/or leukocytes. This assay could be applied for improving the biocompatibility of coronary stents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号