首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In strongly acidic medium (70% HClO4) streptothricins form a fluorophore (lambda ex = 312 nm; lambda em = 381 nm) with unknown structure. A fluorimetric determination of pure or crude products and cultures, respectively, was worked out based on this reaction. Concentrations for fluorescence measurements were in the range of 10(-8) - 2 X 10(-7) moles. Interferences of the assay are discussed, a statistical evaluation of results and a comparison between microbiological and fluorimetric findings are given.  相似文献   

2.
A sensitive and specific fluorimetric assay for the determination of pyruvate is reported here. This assay is based on the oxidation of pyruvate in the presence of pyruvate oxidase. Hydrogen peroxide generated by pyruvate oxidase reacts with nonfluorescent Amplex Red at a 1:1 stoichiometry to form the fluorescent product, resorufin. The assay is optimized with respect to pH of reaction buffer, enzyme concentration, dye concentration, and the time course. The usefulness of the assay is demonstrated by the accurate measurement of intracellular and extracellular pyruvate concentrations. The limit of detection of the assay is 5 nM.  相似文献   

3.
A fluorimetric assay for monitoring depurination of the N7-alkylguanine adduct derived from the anticancer natural product leinamycin is described. This general approach could potentially provide the foundation for a high throughput assay that detects DNA-alkylating agents or a convenient continuous fluorimetric assay for base excision repair enzymes.  相似文献   

4.
A continuous fluorimetric assay for ATPase activity.   总被引:1,自引:0,他引:1       下载免费PDF全文
A new continuous coupled fluorimetric assay is described for ATPases in general. Thus phosphate released from ATP hydrolysis is coupled to the nucleoside phosphorylase reaction using 7-methylguanosine as a fluorescent substrate for the nucleoside phosphorylase reaction. The hydrolysis of 7-methylguanosine leads to 7-methylguanine, which has lower quantum yield and hence can be used to monitor ATP hydrolysis continuously. The method has the potential to be extended to GTPase and nucleotidyltransferase assays.  相似文献   

5.
Angiotensin I-converting enzyme (ACE) assays are commonly used for measuring enzymatic activity in clinical and biological samples. The fluorimetric procedure described is sensitive, rapid and involves unsophisticated procedures and inexpensive reagents. It uses the substrate hippuryl-L-histidyl-L-leucine, and the fluorescent adduct of the enzyme-catalyzed product L-histidyl-L-leucine is quantified fluorimetrically. This assay has been adapted for a 96-well plate format that produces comparable data to previously described assays and has the advantage of greater efficiency with respect to both time and reagents. The protocol can be used for routine purposes or for more detailed kinetic analyses. The apparent Km and kcat values for purified testis ACE determined from a double reciprocal plot were 3.0 mM and 195.7 s(-1), respectively. The protocol can be completed within 4 h.  相似文献   

6.
UDPglucosyltransferase and its kinetic fluorimetric assay   总被引:1,自引:0,他引:1  
A rapid, kinetic assay for UDPglucosyltransferase has been developed using 1-naphthol as substrate. It is based on the continuous fluorimetric monitoring of 1-naphthyl glucoside formation during the reaction at physiological pH. The conjugate is easily distinguished from aglycone, since their fluorimetric properties differ. Glucoside biosynthesis in vitro by microsomal preparations isolated from the gut and fat body of cockroaches Periplaneta americana and Leucophaea maderae, and from the green gland and hepatopancreas of the crayfish Astacus astacus, has been demonstrated. The effects of buffer, pH, MgCl2, UDP-glucuronic acid, UDP-N-acetylglucosamine, sodium cholate and sonication on the enzyme activity have been assessed. The kinetic parameters of 1-naphthol and UDP-glucose have also been determined.  相似文献   

7.
The respiratory burst is an important feature of the immune system. The increase in cellular oxygen uptake that marks the initiation of the respiratory burst is followed by the production of reactive oxygen species (ROS) such as superoxide anion and hydrogen peroxide which plays a role in the clearance of pathogens and tissue regeneration processes. Therefore, the respiratory burst and associated ROS constitute important indicators of fish health status. This paper compares two methods for quantitation of ROS produced during the respiratory burst in common carp: the widely used, single-point measurement based on the intracellular reduction of nitroblue tetrazolium (NBT) and a real-time luminol-enhanced assay based on the detection of native chemiluminescence. Both assays allowed for detection of dose-dependent changes in magnitude of the respiratory burst response induced by β-glucans in head kidney cells of carp. However, whereas the NBT assay was shown to detect the production of only superoxide anions, the real-time luminol-enhanced assay could detect the production of both superoxide anions and hydrogen peroxide. Only the chemiluminescence assay could reliably record the production of ROS on a real-time scale at frequent and continual time intervals for time course experiments, providing more detailed information on the respiratory burst response. The real-time chemiluminescence assay was used to measure respiratory burst activity in macrophage and neutrophilic granulocyte-enriched head kidney cell fractions and total head kidney cell suspensions and proved to be a fast, reliable, automated multiwell microplate assay to quantitate fish health status modulated by β-glucans.  相似文献   

8.
The effect of cyclosporine on PMA-stimulated superoxide production has been studied on human alveolar macrophages, human neutrophils, cytoplasts and Epstein-Barr-virus-transformed B lymphocytes. Cyclosporine inhibits superoxide production in alveolar macrophages but not in neutrophils and cytoplasts. The respiratory burst of B-lymphocytes was scarcely inhibited by cyclosporine. The activity of NADPH oxidase from macrophages and neutrophils was not directly affected by cyclosporine. These data are considered in relation with the proposed mechanism for cyclosporine action and the stimulation of the respiratory burst.  相似文献   

9.
A fluorimetric microassay that uses a redox dye to determine the viability of the flagellate Trichomonas vaginalis has been optimised to provide a more sensitive method to evaluate potential trichomonacidal compounds. Resazurin has been used in recent years to test drugs against different parasites, including trichomonadid protozoa; however, the reproducibility of these resazurin-based methods in our laboratory has been limited because the flagellate culture medium spontaneously reduces the resazurin. The objective of this work was to refine the fluorimetric microassay method previously developed by other research groups to reduce the fluorescence background generated by the media and increase the sensitivity of the screening assay. The experimental conditions, time of incubation, resazurin concentration and media used in the microtitre plates were adjusted. Different drug sensitivity studies against T. vaginalis were developed using the 5-nitroimidazole reference drugs, new 5-nitroindazolinones and 5-nitroindazole synthetic derivatives. Haemocytometer count results were compared with the resazurin assay using a 10% solution of 3 mM resazurin dissolved in phosphate buffered saline with glucose (1 mg/mL). The fluorimetric assay and the haemocytometer counts resulted in similar percentages of trichomonacidal activity in all the experiments, demonstrating that the fluorimetric microtitre assay has the necessary accuracy for high-throughput screening of new drugs against T. vaginalis.  相似文献   

10.
The correlation between automated fluorimetric methods and high-performance liquid chromatography is described for the determination of homovanillic acid and 5-hydroxyindoleacetic acid in cerebrospinal fluid, and for dopamine, 3, 4-dihydroxyphenylacetic acid and homovanillic acid in striata of rat brain. The automated fluorimetric methods for 3, 4-dihydroxyphenylacetic acid and homovanillic acid showed a good correlation with the high-performance liquid chromatographic methodology. The fluorimetric determination for dopamine was somewhat less reliable than the high-performance liquid chromatographic assay. The fluorimetric assay for 5-hydroxyindoleacetic acid correlated poorly with the chromatographic method.  相似文献   

11.
A dimeric derivative of ethidium is used for fluorimetric assay of nucleic acids. Due to the very high binding affinity of this derivative for DNA and RNA, a significant increase of sensitivity of the ethidium fluorimetric technique for nucleic acids determination is obtained. Using a commercially available instrument, DNA concentrations in the nanogram per milliliter range are determined. In addition, we have found that an acridine ethidium dimer can also be used for a sensitive fluorimetric assay of DNA concentration, while simultaneously providing a determination of the DNA base composition.  相似文献   

12.
A purification technique for a large scale production of crystalline Mo-Fe protein of nitrogenase from Azotobacter vinelandii and of its fragment, Fe-Mo-cofactor (Fe-Mo-co) in argon atmosphere has been elaborated. The novel fluorimetric method of thiol compounds analysis has been proposed for identification of Fe-Mo-co thiol ligands; this procedure allows the determination of concentration and class of thiol compounds and of the distance between sulphur atoms in the case of dithiols. The use of this method for an analysis of Fe-Mo-co has demonstrated that it contains a thiomolybdate fragment and two atoms of inorganic sulphur. Organic thiol as a Fe ligand has not been revealed.  相似文献   

13.
A rapid and sensitive fluorimetric assay for inosine and adenosine is described in which either or both metabolites are enzymically converted to hypoxanthine, which is then estimated by the rate of appearance of hydrogen peroxide after the addition of xanthine oxidase. The method has been used to assay solutions over the range 0.2 to 30 μmol/liter although this is not the ultimate sensitivity possible. Uranyl acetate as protein precipitant gave good recovery of inosine and adenosine from blood and was compatible with the assay.  相似文献   

14.
The respiratory burst is an NADPH oxidase-driven reduction of molecular oxygen to superoxide, which can occur in phagocytic cells as part of an antimicrobial defence, and is well documented among the vertebrates. This paper describes a process resembling the respiratory burst, which occurs in the haemolymph and haemocytes of the cockroach, Blaberus discoidalis. The in vitro reduction of nitroblue tetrazolium by superoxide to formazan was measured spectrophotometrically in B. discoidalis haemolymph in response to various immune elicitors. Nitroblue tetrazolium reduction was partly impeded in the presence of superoxide dismutase, a specific antioxidant which converts superoxide to hydrogen peroxide, as well as by chemicals known to inhibit the respiratory burst in vertebrates (trifluoperazine, diphenylene iodonium, and N-ethylmaleimide). This suggests the generation of superoxide anions by haemolymph as part of an immune response. Furthermore, formazan staining of elicitor-treated haemocytes was observed microscopically, with less intense staining in the presence of superoxide dismutase. Finally, respiratory burst inhibitors and superoxide dismutase enhanced the growth of E. coli incubated in whole haemolymph, implying a role for haemolymph-derived superoxide in antibacterial defence.  相似文献   

15.
The induction of the respiratory burst in human neutrophils by combinations of fMLP and either PAF or LTB4 was studied. Pretreatment with PAF (0.0001 to 10 uM), which by itself did not elicit the burst, greatly enhanced the rate and extent of fMLP-induced superoxide production. A synergism of a different kind was observed with the reversed stimulus sequence: Pretreatment with fMLP made the neutrophils capable to respond to PAF with superoxide production. A moderate enhancement of the fMLP response was also obtained following pretreatment with LTB4. The response of the cells to LTB4, however, was not influenced by fMLP, and no synergism was observed between the two neutrophil products PAF and LTB4. The results of this study demonstrate a marked synergism between fMLP and PAF and suggest that PAF may function as an amplifier of the respiratory burst response of stimulated neutrophils.  相似文献   

16.
In this paper we describe a fluorimetric assay for the measurement of long-chain acyl-CoA synthetase activity in rat liver postnuclear supernatants. The method is based upon the use of acyl-CoA oxidase which catalyzes the dehydrogenation of acyl-CoA esters to yield enoyl-CoA esters and H2O2. H2O2 subsequently reacts with homovanillic acid in a horseradish peroxidase-catalyzed reaction to form a highly fluorescent dimer (see G. G. Guilbault, P. J. Brignac, and M. Zimmer (1968) Anal. Chem. 40, 190-196). The increase in fluorescence can be followed either continuously or discontinuously. The method described is able to detect acyl-CoA synthetase activities as low as 20 microU/ml which is almost as sensitive as the standard isotopic assay used in most laboratories. The method is applicable to measure the activation of a variety of fatty acids. Finally, the method provides a simple means of carrying out kinetic studies.  相似文献   

17.
A fluorimetric Morgan-Elson assay method for hyaluronidase activity   总被引:1,自引:0,他引:1  
Despite their physiological importance, hyaluronidases (HAases) have long been "neglected enzymes," due, presumably, in part to the lack of rapid, sensitive assays. Currently, the colorimetric Morgan-Elson assay method, which is based upon the generation of a new reducing N-acetyl-D-glucosamine terminus with each cleavage reaction, is most widely employed but is yet insensitive. We, therefore, reinvestigated the colorimetric method and established the fluorimetric Morgan-Elson assay for HAase activity, with the optimized tetraborate reagent. The fluorimetric assay, requiring neither specialized reagents nor a long time to perform, provided high sensitivity, nearly comparable to that of enzyme-linked immunosorbent assay (ELISA)-like assays, with a detection limit of 5 x 10(-3)NFU/ml of bovine testicular HAase after 1-h incubation. The increased sensitivity permitted rapid measurement of low HAase activity in biological samples such as human and rabbit serum HAases, the latter of which has not been detected either by an ELISA-like assay or by zymography. Human serum HAase was easily characterized it along with its optimum pH and kinetic parameters.  相似文献   

18.
The previously reported method for the estimation of biotinidase (EC 3.5.1.12) is an endpoint colorimetric assay based on the hydrolysis of biotinyl-4-aminobenzoate, followed by diazotization, and is not suitable for our studies of biotinidase. A fluorimetric rate assay of biotinidase which uses a newly synthesized derivative biotinyl-6-aminoquinoline is described here.  相似文献   

19.
A fluorimetric assay was developed to measure halide release from halogenated compounds being degraded by microbes. The method relies on the property of halides to quench the fluorescence of 6-methoxy-N-(3-sulfopropyl)quinolinium (SPQ) by collision quenching. The assay shows a wide response to halide concentration (1-500 mM) and tolerates a wide pH range. Furthermore, it is simple to use, has the potential for automation and uses an inexpensive non-toxic reagent.  相似文献   

20.
A simple and highly sensitive normal-phase HPLC method is described for determining sertindole concentrations in human plasma using fluorimetric detection. A short C8 column was used to extract sertindole and the internal standard from plasma; the column was rinsed with acetonitrile, and the analytes were recovered by elution with methanol. This uncommon selectivity between the two solvents allowed clean extraction and near- quantitative recovery of the analytes (> 89%). Separation was done on a 5-μm silica-gel column and detection was performed by fluorimetry, with emission at 340 nm and excitation at 260 nm. The detection and lower quantifiable limits were 0.01 and 0.025 ng/ml, respectively, with no interference from plasma or potential metabolites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号