1.
We present an optimized and validated liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for the simultaneous measurement of concentrations of different ceramide species in biological samples. The method of analysis of tissue samples is based on Bligh and Dyer extraction, reverse-phase high-performance liquid chromatography separation, and multiple reaction monitoring of ceramides. Preparation of plasma samples also requires isolation of sphingolipids by silica gel column chromatography prior to LC-ESI-MS/MS analysis. The limits of quantification were in a range of 0.01-0.50 ng/ml for distinct ceramides. The method was reliable for inter- and intraassay precision, accuracy, and linearity. Recoveries of ceramide subspecies from human plasma, rat liver, and muscle tissue were 78 to 91%, 70 to 99%, and 71 to 95%, respectively. The separation and quantification of several endogenous long-chain and very-long-chain ceramides using two nonphysiological odd chain ceramide (C17 and C25) internal standards was achieved within a single 21-min chromatographic run. The technique was applied to quantify distinct ceramide species in different rat tissues (muscle, liver, and heart) and in human plasma. Using this analytical technique, we demonstrated that a clinical exercise training intervention reduces the levels of ceramides in plasma of obese adults. This technique could be extended for quantification of other ceramides and sphingolipids with no significant modification.  相似文献   

2.
5-Azacytidine (5AC), a nucleoside analogue and hypomethylating agent, has anticancer properties and has been utilized in the treatment of various malignancies. 5AC is unstable and rapidly hydrolyzed to several by-products, including 5-azacytosine and 5-azauracil. A sensitive, reliable method was developed to quantitate 5AC using LC/MS/MS to perform pharmacokinetic and pharmacodynamic studies on 5AC combination therapy trials. Blood samples were collected in a heparinized tube and immediately processed for storage. To increase the stability of 5AC in plasma, 25 ng/mL tetrahydrouridine was added to the plasma and snap frozen. Plasma samples were extracted using acetonitrile then cleaned up by Oasis MCX ion exchange solid-phase extraction cartridges. 5AC was separated on an YMC Jsphr M80 C(18) column with gradient elution of ammonium acetate (2 mM) with 0.1% formic acid and methanol mobile phase. 5AC elutes at 5.0 +/- 0.2 min with a total run time of 30 min. Identification was through positive-ion mode and multiple reaction monitoring mode at m/z+ 244.9-->113.0 for 5AC and m/z+ 242.0-->126.0 for 5-methyl-2'-deoxycytidine, the internal standard. The lower limit of quantitation of 5AC was 5 ng/mL in human plasma, and linearity was observed from 5 to 500 ng/mL fitted by linear regression with 1/x weight. This method is 50 times more sensitive than previously published assays and successfully allows studies to characterize the pharmacokinetics and pharmacodynamics of 5AC.  相似文献   

3.
The sulfur amino acids, methionine and cysteine play crucial roles in cells as a substrate for protein synthesis, as a methyl donor, and for the synthesis of sulfur-containing compounds, including the key intracellular tripeptide, glutathione. Homocysteine is an intermediary metabolite formed during the metabolism of methionine to cysteine. Dysregulation of homocysteine metabolism is implicated in adverse clinical outcomes such as increased risk of cardiovascular disease, stroke, Alzheimer's disease dementia and osteoporosis. While hyperhomocysteinemia is commonly observed in those conditions, the impact on other related metabolites is condition-specific. Therefore, there exists a need to establish precise and sensitive analytical techniques that allow for the simultaneous measurement of homocysteine and related metabolites in biological samples. The current review outlines the development and use of liquid chromatography electrospray tandem mass spectrometry (LC–MS/MS) to simultaneously measure metabolites involved in sulfur amino acid metabolism. Additionally, extensions of the technique in relation to the measurement of sulfur amino acid and one-carbon kinetics in vivo are discussed. The LC–MS/MS technique has the capacity for unambiguous analyte identification and confirmation, due to its high specificity and sensitivity. It has the greatest potential of being accepted and utilized as a dedicated homocysteine and its related metabolite Standard reference method (SRM).  相似文献   

4.
An off-line solid-phase extraction (SPE) and ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for determining procyanidins, catechin, epicatechin, dimer, and trimer in plasma samples. In the validation procedure of the analytical method, linearity, precision, accuracy, detection limits (LODs), quantification limits (LOQs), and the matrix effect were studied. Recoveries of the procyanidins were higher than 84%, except for the trimer, which was 65%. The LODs and LOQs were lower than 0.003 and 0.01 μM, respectively, for all the procyanidins studied, except for the trimers, which were 0.8 and 0.98 μM, respectively. This methodology was then applied for the analysis of rat plasma obtained 2 h after ingestion of grape seed phenolic extract. Monomers (catechin and epicatechin), dimer and trimer in their native form were detected and quantified in plasma samples, and their concentration ranged from 0.85 to 8.55 μM. Moreover, several metabolites, such as catechin and epicatechin glucuronide, catechin and epicatechin methyl glucuronide, and catechin and epicatechin methyl-sulphate were identified. These conjugated forms were quantified, in reference to the respective unconjugated form, showing concentrations between 0.06 and 23.90 μM.  相似文献   

5.
Methods for the determination of celecoxib in human plasma and rat microdialysis samples using liquid chromatography tandem mass spectrometry are described. Celecoxib and an internal standard were extracted from plasma by solid-phase extraction with C18 cartridges. Thereafter compounds were separated on a short narrow bore RP C18 column (30×2 mm). Microdialysis samples did not require extraction and were injected directly using a narrow bore RP C18 column (70×2 mm). The detection was by a PE Sciex API 3000 mass spectrometer equipped with a turbo ion spray interface. The compounds were detected in the negative ion mode using the mass transitions m/z 380→316 and m/z 366→302 for celecoxib and internal standard, respectively. The assay was validated for human plasma over a concentration range of 0.25–250 ng/ml using 0.2 ml of sample. The assay for microdialysis samples (50 μl) was validated over a concentration range of 0.5–20 ng/ml. The method was utilised to determine pharmacokinetics of celecoxib in human plasma and in rat spinal cord perfusate.  相似文献   

6.
There is considerable evidence that stilbenes provide health benefits. Trans-piceid is one of the major stilbenoid compounds in red wine and other plants. The purpose of this study is to investigate the metabolism of piceid in rats, including its conversion product by intestinal microflora in vitro and urinary metabolites. A HPLC-MS/MS method with electrospray ionization (ESI), negative ion mode and collision induced dissociation (CID), was used to elucidate the structures of the major metabolites of piceid. Three metabolites resveratrol, dihydropiceid and dihydroresveratrol were detected after incubating with gut microbiota for 5h. Four urinary metabolites of piceid were identified as resveratrol, dihydroresveratrol monosulfate, piceid monosulfate and piceid monoglucuronide.  相似文献   

7.
Prostanoids are bioactive substances that contribute to various biological and pathological processes. To evaluate both extracellular and intracellular levels of prostanoids at the same time, we developed methods for quantification of extracellular and intracellular levels of prostanoids, including prostaglandin E(2) (PGE(2)), PGD(2), PGF(2α), 6-keto PGF(1α), and TXB(2), in cultured cells using liquid chromatography/tandem mass spectrometry (LC/MS/MS), and we validated the LC/MS/MS methods. A solid-phase extraction cartridge was used for extraction of prostanoids. The prostanoids were separated by a C(18) column with an isocratic flow of acetonitrile/water/acetic acid (40:60:0.1, v/v/v). Calibration curves of extracellular measurement for the prostanoids were linear in the range from 0.1 to 100 ng/mL (r(2)>0.999), and those of intracellular measurement were linear in the range from 0.05 to 50 ng (r(2)>0.999). Validation assessment showed that both methods of extracellular and intracellular measurements were highly reliable with good accuracy and precision. We also applied the methods to human airway epithelial Calu-3 cells and human lung adenocarcinoma epithelial A549 cells.  相似文献   

8.
A sensitive and specific method using a one-step liquid-liquid extraction (LLE) with ethyl acetate followed by high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed and validated for the determination of roxatidine in human plasma using famotidine as an internal standard (IS). Data acquisition was carried out in multiple reaction monitoring (MRM) mode, by monitoring the transitions m/z 307.3-->107.1 for roxatidine and m/z 338.4-->189.1 for famotidine. Chromatographic separation was performed on a reverse phase Hydrosphere C(18) column at 0.2 mL min(-1) using a mixture of methanol-ammonium formate buffer as mobile phase (20:80, v/v; adjusted to pH 3.9 with formic acid). The achieved lower limit of quantification (LLOQ) was 1.0 ng mL(-1) and the standard calibration curve for roxatidine was linear (r(2)=0.998) over the studied range (1-1000 ng mL(-1)) with acceptable accuracy and precision. Roxatidine was found to be stable in human plasma samples under short-, long-term storage and processing conditions. The developed method was validated and successfully applied to the bioequivalence study of roxatidine administrated as a single oral dose (75 mg as roxatidine acetate hydrochloride) to healthy female Korean volunteers.  相似文献   

9.
A selective, rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantitative determination of mitiglinide in human plasma. With nateglinide as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.2 mL plasma. The separation was performed on an ACQUITY UPLCtrade mark BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with the mobile phase consisting of methanol and 10 mmol/L ammonium acetate (65:35, v/v) at a flow rate of 0.25 mL/min. The detection was carried out by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 1.080-5400 ng/mL, with a lower limit of quantification of 1.080 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was from -3.5% to 7.3% at all QC levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of mitiglinide in 10 healthy volunteers following oral administration.  相似文献   

10.
Promoter hypermethylation-associated tumor suppressor gene (TSG) silencing has been explored as a therapeutic target for hypomethylating agents. Promoter methylation change may serve as a pharmacodynamic endpoint for evaluation of the efficacy of these agents and predict the patient’s clinical response. Here a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been developed for quantitative regional DNA methylation analysis using the molar ratio of 5-methyl-2′-deoxycytidine (5mdC) to 2′-deoxycytidine (2dC) in the enzymatic hydrolysate of fully methylated bisulfite-converted polymerase chain reaction (PCR) amplicons as the methylation indicator. The assay can differentiate 5% of promoter methylation level with an intraday precision ranging from 3 to 16% using two TSGs: HIN-1 and RASSF1A. This method was applied to characterize decitabine-induced promoter DNA methylation changes of these two TSGs in a breast cancer MCF-7 cell line. Promoter methylation of these TSGs was found to decrease in a dose-dependent manner. Correspondingly, the expression of these TSGs was enhanced. The sensitivity and reproducibility of the method make it a valuable tool for specific gene methylation analysis that could aid characterization of hypomethylating activity on specific genes by hypomethylating agents in a clinical setting.  相似文献   

11.
A rapid, sensitive and specific method to quantify carvedilol in human plasma using metoprolol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a diethyl-ether solvent. After removed and dried the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile-water (50/50; v/v). The extracts were analyzed by a high performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed isocratically on Alltech Prevail C18 5 microm analytical column, (150 mm x 4.6 mm i.d.). The method had a chromatographic run time of 3.5 min and a linear calibration curve over the range 0.1-200 ng ml(-1) (r2>0.997992). The limit of quantification was 0.1 ng ml(-1). This HPLC-MS/MS procedure was used to assess the bioequivalence of two carvedilol 25 mg tablet formulations (carvedilol test formulation from Laboratórios Biosintética Ltda and Coreg from Roche Químicos e Farmacêuticos S.A standard reference formulation). A single 25 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2-week wash-out interval. Since the 90% CI for C(max) and AUCs ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration Agency, it was concluded that carvedilol formulation elaborated by Laboratórios Biosintética Ltda is bioequivalent to Coreg formulation for both the rate and the extent of absorption.  相似文献   

12.
The F2-isoprostanes (F2-IsoP) are a series of prostaglandin (PG)-F2-like compounds that are produced by free-radical-mediated oxidation of arachidonic acid. One F2-IsoP with potent biological activity is 15-F2t-IsoP and increased levels of 15-F(2t)-IsoP have been measured in several diseases. The major urinary metabolite of 15-F2t-IsoP (8-iso-PGF(2alpha)) is 2,3-dinor-5,6-dihydro-15-F2t-IsoP (15-F2t-IsoP-M). Previously, we developed a stable isotope dilution gas chromatography/negative chemical ionization/mass spectrometry (MS) assay for 15-F2t-IsoP-M, which, while highly sensitive, required time-consuming derivatization and thin-layer chromatography purification. We now report the development of a more rapid high-performance liquid chromatography method coupled to electrospray ionization-tandem mass spectrometry (LC/MS/MS) to analyze all of the dinor,dihydro metabolites of the F2-IsoP isomers (F2-IsoP-M). The precision of this assay was +/-5.0% and the accuracy 80%. The assay remained linear over a range of 1-100 ng injected onto the LC column. Levels of F2-IsoP-M determined by the LC/MS/MS assay method significantly correlated with levels of 15-F2t-IsoP-M determined by the GC/MS assay (R = 0.77y = 67.2x-0.5). The levels of F2-IsoP-M detected in spot urines from 40 normal subjects were 38.1+/-19.1 ng/mg creatinine (mean+/-SD). This method provides an accurate and rapid assay to assess oxidative status in vivo.  相似文献   

13.
A sensitive, selective and quantitative method for the simultaneous determination of casopitant, a potent and selective antagonist of the human Neurokinin 1 (NK-1) receptor, and its three major metabolites M12, M13 and M31 was developed and validated in dog and rat plasma. Acetonitrile containing stable labeled internal standards for the four analytes was used to precipitate proteins in plasma. Chromatographic separation was obtained using a reversed phase column with multiple reaction monitoring turboionspray positive ion detection. The lower and upper limits of quantification for casopitant and its metabolites were 15 and 15,000 ng/mL, using a 50 μL of dog or rat plasma aliquot, respectively. The inter-day precision (relative standard deviation) and accuracy (relative error) in dog plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 4.1% to 10.0% and −10.8% to 8.7%, respectively, for casopitant and its 3 major metabolites. The intra-day precision (relative standard deviation) and accuracy (relative error) in rat plasma, derived from the analysis of validation samples at 5 concentrations, ranged from 3.9% to 6.6% and −9.6% to 8.3%, respectively, for casopitant and its three metabolites. All analytes were found to be stable in analytical solutions for at least 43 days at 4 °C, in dog and rat plasma at room temperature for at least 24 h, at the storage temperature of −20 °C for at least 6 months, and following the action of three freeze–thaw cycles from −20 °C to room temperature. All analytes were also found to be stable in processed extracts at 4 °C for at least 72 h. This assay proved to be accurate, precise, fast and was used to support long-term toxicology studies in dog and rat.  相似文献   

14.
A method for the quantification of salidroside, a major biologically active compound in Rhodiola, in rat plasma by on-line SPE LC/MS/MS in negative electrospray mode was developed and validated. A column-switching instrument and two HPLC pumping systems were employed, and salicin was used as the internal standard. A Waters Oasis HLB extraction column and an Agilent TC-C(18) analytical column in a column-switching set-up with gradient elution were utilized. The MS/MS ion transitions monitored were m/z 299.0/119.0 and 285.1/122.9 for salidroside and salicin, respectively. The standard curves were linear within a range of 50-5000 ng/mL using weighted linear regression analysis (1/x). The intra- and inter-day coefficients of variance ranged from 1% to 9%. The recovery was above 90%. The freeze/thaw and long-term stability were validated. This method was subsequently applied to a pharmacokinetic study of salidroside in rats.  相似文献   

15.
Rapid and sensitive analytical methods using liquid chromatography with tandem mass spectrometry (LC/MS/MS) were developed for the determination of ticagrelor, the first reversible oral platelet P2Y12 receptor inhibitor, and its metabolites AR-C124910XX and AR-C133913XX in human plasma. Ticagrelor and its metabolites were extracted using protein precipitation with acetonitrile. Chromatographic separations were performed on reversed phase columns and detection using atmospheric pressure chemical ionization (APCI). Ticagrelor and AR-C124910XX were analyzed in the same assay, with the internal standard, d7-ZD6140, on a C18 column using negative ionization; AR-C133913XX analyzed separately on a phenyl column using positive ionization. Full validation of the methods was performed including selectivity, lower limit of quantification, accuracy, precision stability and incurred sample reproducibility and incurred sample stability. Total analytical run time was short (2 min). Calibration curves were established in the range 5–5000 ng/mL for ticagrelor, 2.5–2500 ng/mL for AR-C124910XX and 2–1000 ng/mL for AR-C133913XX. Lower limits of quantification for ticagrelor, AR-C124910XX and AR-C133913XX were determined to be 5, 2.5 and 2.0 ng/mL, respectively from 100 μL of human plasma. For ticagrelor, AR-C124910XX and AR-C133913XX, mean intra-batch accuracy was 91.9–109.0%, 86.8–109.2% and 100.5–112.0%, respectively; intra-batch precision was 4.0–8.4%, 5.2–16.9% and 3.9–12.3%, respectively. The methods were also applied to quantification of ticagrelor, AR-C124910XX and AR-C133913XX in rabbit, rat, mouse and marmoset, using 25 μL of animal plasma. A modified methodology was developed to quantify ticagrelor and AR-C124910XX in plasma from dog and cynomolgus monkey. Human incurred samples were found to generate consistent reproducibility and stability results. This method was successfully applied to determine plasma concentrations following administration of ticagrelor in human volunteers and patients, and animal safety evaluation studies. This validated methods has the advantages of being straightforward, robust and allows a fast throughput of samples.  相似文献   

16.
A simple and highly sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed to compare endogenous cannabinoid levels in nematodes and in brains of rats and humans, with and without prior exposure to ethanol. After liquid-liquid extraction of the lipid fraction from homogenized samples, a reversed-phase sub 2 μm column was used for separating analytes with an isocratic mobile phase. Deuterated internal standards were used in the analysis, and detection was made by triple quadrupole mass spectrometer with multiple reaction monitoring (MRM). Ionization was performed with positive electrospray ionization (ESI). The nematode Caenorhabditis elegans fat-3 mutant, that lacks the necessary enzyme to produce arachidonic acid, the biologic precursor to 2-arachidonoyl glycerol and anandamide, was used as an analyte-free surrogate material for selectivity and calibration studies. The matrix effect was further investigated by in-source multiple reaction monitoring (IS-MRM) and standard addition studies. Selectivity studies demonstrated that the method was free from matrix effects. Good accuracy and precision were obtained for concentrations within the calibration range of 0.4-70 nM and 40-11,000 nM for monitored N-acylethanolamides (NAEs) and acyl glycerols, respectively.  相似文献   

17.
Astragaloside IV (AGS-IV) is an active constituent of Radix Astragali used in many Traditional Chinese Medicines. This paper describes a sensitive and specific assay for the quantitation of AGS-IV in rat plasma. After solid phase extraction (SPE), samples were analyzed by liquid chromatography electrospray ionization mass spectrometry using a reversed-phase C18 column. The assay was linear in the range 1-500 ng/ml with a limit of detection of 0.5 ng/ml. The recovery was 92.5% and within-day and between-day precision were 3.7-6.0 and 2.8-9.8%, respectively. The assay was applied to a pharmacokinetic study in rat after a single oral dose. The drug was rapidly absorbed and subsequently eliminated according to a biphasic concentration-time curve.  相似文献   

18.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been validated for the quantitative determination of the three major paclitaxel metabolites (6α-hydroxypaclitaxel, 3′-p-hydroxypaclitaxel, 6α,3′-p-dihydroxypaclitaxel) in human plasma. The HPLC system consists of an APEX-octyl analytical column and acetonitrile-methanol-0.02 M ammonium acetate buffer pH 5 (AMW; 4:1:5, v/v/v) as the mobile phase. Detection is performed by UV absorbance measurement at 227 nm. The sample pretreatment of the plasma samples involves solid-phase extraction (SPE) on Cyano Bond Elut columns.The concentrations of the metabolic products could be determined by using the paclitaxel standard curve with a correction factor of 1.14 for 6α,3′-p-dihydroxypaxlitaxel. The recoveries of paclitaxel and the metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in human plasma were 89, 78, 91 and 89%, respectively. The accuracy of the assay for the determination of paclitaxel and its metabolites varied between 95 and 97%, at a 50 ng/ml analyte concentration. The lower limit of quantitation was 10 ng/ml for both the parent drug and its metabolites.  相似文献   

19.
PM01218 is a novel marine-derived alkaloid and has shown potent growth inhibitory activity against several human cancer cell lines. A rapid and sensitive high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method was developed and validated to quantify PM01218 in mouse and rat plasma. The lower limit of quantitation (LLOQ) was 0.05 ng/mL. The calibration curve was linear from 0.05 to 100 ng/mL (R(2)>0.999). The assay was specifically based on the multiple reaction monitoring (MRM) transitions at m/z 278.4-->184.2, no endogenous material interfaced with the analysis of PM01218 and its internal standard from blank mouse and rat plasma. The mean intra- and inter-day assay accuracy remained below 15 and 8%, respectively, for all calibration standards and QC samples. The intra- and inter-day assay precision was less than 12.8 and 8.5% for all QC levels, respectively. The utility of the assay was demonstrated by pharmacokinetics studies of i.v. (bolus) PM01218 on SD rats.  相似文献   

20.
The apolipoprotein A-I mimetic peptide D-4F is a potential therapeutical agent effective in maintaining cardiovascular health. A bioanalytical assay based on high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC/MS/MS) to quantitate the D-4F amount in rabbit plasma was developed and validated. A compound with a close structure similarity to the D-4F (only one amino acid A–V altered) was used as an internal standard. Both D-4F and the internal standard were extracted by protein precipitation using acetonitrile/0.2% Triton XL 80N. The correlation coefficient of the calibration curve was 0.9991 in the range 20–40,000 ng/mL. This assay can be used for pharmacokinetic studies of the drug. Also, it may be adjusted for the quantification of other members of apolipoprotein A-I mimetic peptide family.  相似文献   