首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
A method is described for the quantitative confirmation of halofuginone (HFG) residues in chicken liver and eggs. This method is based on LC coupled to positive ion electrospray MS-MS of the tissue extracts, prepared by trypsin digestion of the tissues followed by liquid-liquid extraction and final clean-up using Solid Phase Extraction (SPE). The [M+H](+) ion at m/z 416 is monitored along with four transitions at m/z 398, 138, 120 and 100. The method has been validated according to the draft EU criteria for the analysis of veterinary drug residues at 15, 30 and 45 microg kg(-1) in liver and 5, 15 and 50 microg kg(-1) in eggs. The new analytical limits, CCalpha and CCbeta were calculated for liver and were 35.4 and 43.6 microg kg(-1), respectively.  相似文献   

2.
Cyadox (CYX) is an antimicrobial growth-promoter of the quinoxalines. It is highly effective on improving growth and feed conversion of chicken with little toxicity. For food safety concerns, HPLC-UV methods were developed for the sequential determination of CYX and its major metabolites, 1,4-bisdesoxycyadox (BDCYX) and quinoxaline-2-carboxylic acid (QCA), in plasma, muscle, liver, kidney and fat of chicken. For CYX and BDCYX, samples were subjected to a deproteinisation, a degrease and a liquid-liquid extraction. For QCA, samples were subjected to an alkali hydrolysis, a liquid-liquid extraction and a cation exchange column (AG MP-50 resin) clean-up. Analysis was performed on a RP-C18 column by UV detection with a gradient program of wavelength. Gradient elution was performed at a flow of 1mL/min. The limits of quantification for CYX, BDCYX and QCA in plasma and tissues were 0.025microg/g, and 0.002microg/g for QCA in muscle. The recoveries of three compounds in plasma and tissues were 70-87% with inter-day relative standard deviation (R.S.D.) less than 10%. An animal experiment was performed to show the applicability of the present methods in real biological samples, which demonstrated a satisfactory applicability since all compounds could be detected nearly in all tissues. The present methods were highly sensitive and accurate, and could therefore be useful in pharmacokinetic and residue studies for cyadox in chicken. The developed methods will be further applied in the residue screening of cyadox and its metabolites in chicken.  相似文献   

3.
A liquid chromatography/electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the first time for the determination of ibogaine and noribogaine in human plasma and whole blood. The method involved solid phase extraction of the compounds and the internal standard (fluorescein) from the two matrices using OasisHLB columns. LC separation was performed on a Zorbax eclipse XD8 C8 column (5 microm) with a mobile phase of acetonitrile containing 0.02% (v/v) trimethylamine and 2mM ammonium formate buffer. MS data were acquired in single ion monitoring mode at m/z 311.2, 297.2 and 332.5 for ibogaine, noribogaine and fluorescein, respectively. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (0.89-179 microg/l for ibogaine; 1-200 microg/l for noribogaine) and to whole blood concentrations (1.78-358 microg/kg for ibogaine; 2-400 microg/kg for noribogaine). Precision ranged from 4.5 to 13% and accuracy was 89-102%. Dilution of the samples had no influence on the performance of the method. Extraction recoveries were > or =94% in plasma and > or =57% in whole blood. The lower limits of quantitation were 0.89 microg/l for ibogaine and 1 microg/l for noribogaine in plasma, and 1.78 microg/kg for ibogaine and 2 microg/kg for noribogaine in whole blood. In frozen plasma samples, the two drugs were stable for at least 1 year. In blood, ibogaine and noribogaine were stable for 4h at 4 degrees C and 20 degrees C and 2 months at -20 degrees C. The method was successfully used for the analysis of a poisoning involving Tabernanthe iboga root.  相似文献   

4.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for simultaneous quantitation of dexamethasone palmitate and dexamethasone in human plasma was developed. After sample preparation by protein precipitation and liquid-liquid extraction, the analytes and internal standard (IS) were separated on a Venusil XBP-C8 column using gradient elution. Multiple reaction monitoring of dexamethasone palmitate, dexamethasone and IS used the precursor to product ion transitions at m/z 631.8-->373.1, m/z 393.2-->147.1 and m/z 264.2-->58.1, respectively. The method was linear over the ranges 1.5-1000ng/mL for dexamethasone palmitate and 2.5-250ng/mL for dexamethasone with intra- and inter-day precisions of <10% and accuracies of 100+/-7%. The assay was applied to a clinical pharmacokinetic study involving the injection of dexamethasone palmitate to healthy volunteers.  相似文献   

5.
We have developed and validated a new, reliable and very sensitive method for the determination of the urinary metabolites of the most common pyrethroids in one analytical run. After acidic hydrolysis for the cleavage of conjugates, the analytes cis-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (cis-Cl(2)CA), trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (trans-Cl(2)CA), cis-3-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid (Br(2)CA), 4-fluoro-3-phenoxybenzoic acid (F-PBA) and 3-phenoxybenzoic acid (3-PBA) were extracted from the matrix with a liquid-liquid extraction procedure using n-hexane under acidic conditions. For further clean-up, NaOH was added to the organic phase and the carboxylic acids were re-extracted into the aqueous phase. After acidification and extraction into n-hexane again, the metabolites were then derivatised to volatile esters using N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamid (MTBSTFA). Separation and detection were carried out using capillary gas chromatography with mass-selective detection (GC-MS). 2-Phenoxybenzoic acid (2-PBA) served as internal standard for the quantification of the pyrethroid metabolites. The limit of detection for all analytes was 0.05 microg/l urine. The RSD of the within-series imprecision was between 2.0 and 5.4% at a spiked concentration of 0.4 microg/l and the relative recovery was between 79.3 and 93.4%, depending on the analyte. This method was used for the analysis of urine samples of 46 persons from the general population without known exposure to pyrethroids. The metabolites cis-Cl(2)CA, trans-Cl(2)CA and 3-PBA could be found in 52, 72 and 70% of all samples with median values of 0.06, 0.11 and 0.16 microg/l, respectively. Br(2)CA and F-PBA could also be detected in 13 and 4% of the urine samples.  相似文献   

6.
We report here a quantitative method for the analysis of ABT-578 in human whole blood samples. Sample preparation was achieved by a semi-automated 96-well format liquid-liquid extraction (LLE) method. Aluminum/polypropylene heat seal foil was used to enclose each well of the 96-well plate for the liquid-liquid extraction. A liquid chromatography combined with tandem mass spectrometry (LC-MS/MS) method with pre-column regeneration was developed for the analysis of sample extracts. Selective reaction monitoring (SRM) of the mass transitions m/z 983-935 and m/z 931-883 was employed for the detection of ABT-578 and internal standard, respectively. The ammonium adduct ions [M + NH(4)](+) generated from electrospray ionization were monitored as the precursor ions. The assay was validated for a linear dynamic range of 0.20-200.75ng/ml. The correlation coefficient (r) was between 0.9959 and 0.9971. The intra-assay CV (%) was between 1.9 and 13.5% and the inter-assay CV (%) was between 4.7 and 11.3%. The inter-assay mean accuracy was between 86.4 and 102.5% of the theoretical concentrations.  相似文献   

7.
A sensitive method for the determination of Delta(9)-tetrahydrocannabinol and its metabolites, 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid and 11-hydroxy-Delta(9)-tetrahydrocannabinol, in rat and guinea pig plasma was developed using high-performance liquid chromatographic separation with electrospray ionization mass spectrometry detection and a simple liquid-liquid extraction technique. The mean recoveries for Delta(9)-tetrahydrocannabinol, 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid, and 11-hydroxy-Delta(9)-tetrahydrocannabinol were 96, 92, and 85%, respectively. The lower limit of quantification (LLOQ) for all three compounds was 5 ng/ml and the limit of detection (LOD) was 2 ng/ml. This assay method utilizes the increased sensitivity and selectivity of mass spectrometric (MS) detection and a simple extraction step for the determination of Delta(9)-tetrahydrocannabinol and its metabolites in plasma, and thus yields a more efficient pharmacokinetic analysis method than has previously been described.  相似文献   

8.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

9.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

10.
A modified specific, sensitive and reproducible chiral gas chromatographic (GC) method for the resolution and quantification of ethosuximide enantiomers in urine and plasma was developed. The samples were extracted by liquid-liquid extraction, using diethylether and the enantiomers were separated and quantified on a chiral gas chromatographic column (25QC2 / CYDEX- beta 0.25). The method involved the use of GC/MS instrumentation for the acquisition of data in the electron impact selective-ion monitoring mode, collecting ions characteristic of both ethosuximide and alpha, alpha - dimethyl - beta - methylsuccinimide, the internal standard and of mass-to-charge ratio (m/z) exactly equal to 55 and 70 units. The limit of quantitation of the method was 2.5 microg/ml for both urine and plasma with both enantiomers. The method proved to be linear, precise and reproducible in the 5-300 microg/ml concentration range for urine samples and in the 10-250 microg/ml concentration range for plasma samples. Future research work envisaged the application of this method in pharmacokinetic and pharmacodynamic studies.  相似文献   

11.
A liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantification of major chlorpyrifos (CP) metabolites, i.e. diethyl thiophosphate (DETP), diethyl phosphate (DEP), and 3,5,6-trichloro-2-pyridinol (TCP), in human urine was developed. Simultaneous separation of the parent compound and its primary biotransformation products was achieved within 20 min in gradient elution mode employing a mixed-mode reversed-phase/weak anion exchange (RP/WAX) separation principle. The analytical method was developed for a toxicokinetic study of an acute poisoning incidence with a CP containing pesticide formulation. An initial mass spectrometric screening performed with unprocessed urine samples revealed that CP is not excreted unchanged by the kidney. Hence, the quantitative assay was validated for DETP (quantifier transition: m/z 169-->95, qualifier transition: m/z 169-->141), DEP (m/z 153-->79, 153-->125), and TCP (m/z 196-->35, 198-->35) taking dibutyl phosphate (DBP) (m/z 209-->79, 209-->153) as internal standard. Clean-up of urine samples prior to LC-ESI-MS/MS analysis was carried out by a liquid-liquid extraction step with a mixture of ethylacetate and acetonitrile (70:30; v/v). Linearity was observed between 0.25 and 75 mgL(-1), and the signal-to-noise ratio at 0.25 mgL(-1) was better than six for the individual analytes. Recoveries, precision, and accuracies were all adequate across the validated range of 1-75 mgL(-1) for the present toxicological case study.  相似文献   

12.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration.  相似文献   

13.
A simple method using a one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether (MTBE) followed by high-performance liquid chromatography (HPLC) with negative-ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of cilnidipine in human plasma using benidipine as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 491.1>121.8 for cilnidipine and m/z 504.2>122.1 for IS, respectively. Analytes were chromatographed on a CN column by isocratic elution using 10mM ammonium acetate buffer-methanol (30:70, v/v; adjusted with acetic acid to pH 5.0). Results were linear (r2=0.99998) over the studied range (0.1-20ng/ml) with a total LC-MS/MS analysis time per run of 3min. The developed method was validated and successfully applied to a cilnidipine bioequivalence study in 24 healthy male volunteers.  相似文献   

14.
The validation of a LC/MS/MS method for the determination of 8-methoxypsoralen (8-MOP) in human plasma and microdialysates after topical application is described. Plasma samples were extracted by liquid-liquid extraction with diisopropylether using 4,5',8-trimethylpsoralen (TMP) as internal standard. Chromatographic separation of plasma sample extracts was carried out using a short narrow-bore Nucleosil C18 column (30 mm x 2.0 mm i.d.) with acetonitrile/(2 mM ammonium acetate buffer, 2 mM acetic acid) (80:20, v/v). For mass spectrometric analysis an API 3000 triple quadrupole mass spectrometer was employed. The mass transitions used were m/z 217.2-->174.0 for 8-MOP and m/z 229.1-->142.1 for TMP. Microdialysis samples diluted with an equal amount of acetonitrile did not require any extraction and were analyzed directly on a narrow-bore Nucleosil C18 column (70 mm x 2.0mm i.d.) with acetonitrile/(2 mM ammonium acetate buffer, 2 mM acetic acid) (50:50, v/v) with the mass transition m/z 217.2-->174.0. The assays were validated over the concentration ranges of 0.5-50 ng/ml for plasma samples and 0.25-50 ng/ml for microdialysates, respectively.  相似文献   

15.
Liquid chromatography-electrospray ionization mass spectrometry methods are described for the simultaneous quantification of a bis-thiazolium compound (T3), its related prodrug (TE3) and an intermediate compound (mTE3) that appeared during the prodrug/drug conversion process, in human plasma, whole blood and red blood cells (RBCs). The methods involve solid phase extraction (SPE) of the compounds and the internal standard (verapamil) from the three different matrices using OasisHLB columns with an elution solvent of 2x1 ml of acetonitrile containing 1 ml/l trifluoroacetic acid (TFA). HPLC separation was performed on a C18 encapped Xterra column packed with 3.5 microm particles. The mobile phase used a 8 min gradient, from water containing 1 ml/l TFA to acetonitrile containing 1 ml/l TFA, at a flow rate of 400 microl/min. Verapamil and the TE3 compound were characterized by the protonated molecules at m/z 455 and m/z 541, respectively. The mTE3 species was detected through the (M)+ ion at m/z 497. The T3 compound was detected by use of two ions, the quaternary ammonium salt (M2+/2) at m/z 227.3 and by the adduct with TFA (M+TFA)+ at m/z 567.3. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (or whole blood) concentrations in the tested range of 6.4-1282 microg/l (12.8-2564 microg/kg) for T3, 20-2000 microg/l (40-4000 microg/kg) for mTE3 and 10-2000 microg/l (40-4000 microg/kg) for TE3, and to T3 concentrations in RBCs ranging from 12.8 to 2564 microg/kg. Inter-assay precision (in terms of R.S.D.) was below 13.5% and accuracy ranged from 95.4 to 107%. The dilution of the samples (plasma or whole blood) has no influence on the performance of the methods. The extraction recoveries averaged 87% for T3, 53% for mTE3 and 79% for TE3 in plasma; 79% for T3, 57% for mTE3 and 65% for TE3 in blood; and 93% for T3 in RBCs, and was constant across the calibration range. The lower limits of quantitation were 6.4 microg/l for T3, 20 microg/l for mTE3 and 10 microg/l for TE3 in plasma; 12.8 microg/kg for T3 and 40 microg/kg for mTE3 and TE3 in blood; and 12.8 microg/kg for T3 in RBCs. Stability tests under various conditions were also investigated. The three-step SPE procedure (loading, clean-up, and elution) described in this paper to quantify these new anti-malarial compounds in plasma, whole blood and RBCs, can easily be automated by using either robotisation or an automated sample preparation system.  相似文献   

16.
Tacrolimus (FK506) is a potent immunosuppressant widely used for organ transplantation patients while diltiazem (DTZ), a calcium-channel inhibitor, is often used in renal transplantation patients to prevent post-transplant hypertension. However, DTZ has a significant pharmacokinetic interaction with FK506. In this study, a rapid and sensitive ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the simultaneous determination of FK506 and DTZ in human whole blood using ascomycin as the internal standard (IS). After extraction of the whole blood samples by ethyl acetate, FK506, DTZ and the IS were subjected to LC/MS/MS analysis using electro-spray positive-ion mode ionization (ESI(+)). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The MS/MS detection was conducted by monitoring the fragmentation of 821.7-->768.9 (m/z) for FK506, 415.5-->310.3 (m/z) for DTZ and 809.8-->757.0 (m/z) for IS. The method had a chromatographic running time of approximately 2 min and linear calibration curves over the concentrations of 0.5-200 ng/mL for FK506 and 2-250 ng/mL for DTZ. The recoveries of liquid-liquid extraction method were 58.3-62.6% for FK506 and 50.4-58.8% for DTZ. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for FK506 and 2 ng/mL for DTZ. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL for FK506 and 5, 25, and 100 ng/mL for DTZ. The validated LC/MS/MS method has been successfully used to analyze the concentrations of FK506 and DTZ in whole blood samples from pharmacokinetic studies in renal transplanted patients.  相似文献   

17.
A liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) for the determination of ulifloxacin, the active metabolite of prulifloxacin, in human plasma is described. After sample preparation by protein precipitation with methanol, ulifloxacin and ofloxacin (internal standard) were chromatographically separated on a C(18) column using a mobile phase consisting of methanol, water and formic acid (70:30:0.2, v/v/v) at a flow rate of 0.5 ml/min and then were detected using MS/MS by monitoring their precursor-to-product ion transitions, m/z 350-->m/z 248 for ulifloxacin and m/z 362-->m/z 261 for ofloxacin, in selected reaction monitoring (SRM) mode. Positive electrospray ionization was used for the ionization process. The linear range was 0.025-5.0 microg/ml for ulifloxacin with a lower limit of quantitation of 0.025 microg/ml. Within- and between-run precision was less than 6.6 and 7.8%, respectively, and accuracy was within 2.0%. The recovery ranged from 92.1 to 98.2% at the concentrations of 0.025, 0.50 and 5.0 microg/ml. Compared with the reported LC method, the present LC-MS/MS method can directly determine the ulifloxacin in human plasma without any need of derivatization. The present method has been successfully used for the pharmacokinetic studies of a prulifloxacin formulation product after oral administration to healthy volunteers.  相似文献   

18.
A simple and specific method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of etodolac in human plasma, using indomethacin as an internal standard (IS). Chromatographic separation was performed isocratically using a Capcellpak MGII C(18) column with 65% acetonitrile and 35% water containing 10mM ammonium formate (adjusted to pH 3.5 with formic acid). Acquisition was performed in multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 287.99>172.23 for etodolac and m/z 357.92>139.01 for IS. The method was validated to determine its selectivity, linearity, sensitivity, precision, accuracy, recovery and stability. The limit of quantitation (LLOQ) was 0.1microg/mL with a relative standard deviation of less than 15%. The devised method provides an accurate, precise and sensitive tool for determining etodolac levels in plasma.  相似文献   

19.
The dimeric pyrrolobenzodiazepine SJG-136 (NSC 694501) has potent in vitro cytotoxicity and in vivo antitumor activity. SJG-136 binds in the minor groove of DNA and produces G-G interstrand cross-links via reactive N(10)-C(11)/N(10')-C(ll') imine/carbinolamine moieties. We have developed a sensitive, specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method for the quantitative determination of SJG-136 in plasma. SJG-136 was isolated by solid phase extraction through a C8 column, reverse-phase HPLC separation was accomplished on a C18 column with isocratic elution and MS/MS detection, monitoring the m/z 557-m/z 476 transition after electrospray ionization. The linear range and lower limit of quantitation from plasma standard curves were 2.8-1800 nM, and 5 nM, respectively. SJG-136 plasma protein binding was species-dependent. Values of the unbound fraction in human, rat and mouse were 25%, 16.2% and <1%, respectively. Protein binding was saturable in dog plasma where the unbound fraction increased from 10.8% to 22.3% over a 22-720 nM concentration range. SJG-136 pharmacokinetics after a single intravenous dose were best fit to a two-compartment open model with elimination half-life and plasma clearance values of 97 min and 6.1 mL/min/kg, respectively. SJG-136 did not accumulate in plasma following intravenous administration of 1.0 microg/kg doses for five consecutive days.  相似文献   

20.
A fast analysis method using liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry was developed for the simultaneous determination of the 1-hydroxypyrene (1-OHP) and 3-hydroxybenzo[a]pyrene (3-OHBaP) in urine. Mass transitions were monitored at m/z 219.3-200.0 for 1-OHP and m/z 269.2-252.2 for 3-OHBaP. Only 10 min was needed for the analysis. The recovery was 60% for 3-OHBaP and 91% for 1-OHP, respectively. And the method detection limits were 0.49 microg/L for 1-OHP and 1.03 microg/L for 3-OHBaP. The inter- and intra-day relative standard deviations were in the range of 2.8-8.9% for 1-OHP and 9.7-20.8% for 3-OHBaP, respectively. The developed method was successfully used to measure urinary PAH metabolites of student volunteers in a high school.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号