首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A validated gas chromatography-mass spectrometry (GC-MS) detection method for the quantitative analysis of sterol oxidation products (SOPs) in serum is described. After a lipid extraction procedure with chloroform-methanol, a cold saponification and purification by solid phase extraction, oxysterols were derivatized to form trimethyl-sylil-ethers which were subjected to GC-MS analysis. Calibration curves for cholesterol oxidation products showed determination coefficient (R(2)) of 1.0, with low values for the coefficient of variation of the response factors (< 1%). Detection and quantification limits were below 5 ng/mL and 10 ng/mL, respectively. Recovery data were between 77.65% and 110.29% (CV < 10% for all compounds). Good results were obtained for within- and between-day repeatability, with values below 10%. In conclusion, the method performed is suitable for the determination and quantification of SOPs in serum.  相似文献   

2.
4 h after intravenous injection of recombinant HuTNF-alpha to fed rats, an increase in heart, diaphragm, and plasma lipoprotein lipase activity was observed. At the same time, a 40-60% decrease in enzymic activity in epididymal fat pad and kidney and 40% decrease in hepatic lipase activity in liver had occurred. Similar results were obtained 20 h after injection of recombinant HuTNF-alpha into fasted rats. Pretreatment with Indomethacin did not affect the changes in tissue lipoprotein lipase activity observed following recombinant HuTNF-alpha administration. Serum triacylglycerol concentration increased by 2- and 6-fold; 4 and 20 h after recombinant HuTNF-alpha administration. Disappearance of 14C-labeled triacylglycerol from the circulation after injection of small chylomicrons, biosynthetically labeled in their triacylglycerol and cholesterol moieties, was lower in TNF-treated than in control rats. However, the clearance rate of triacylglycerol was the same or even higher in recombinant HuTNF-alpha treated rats (assuming that 14C-labeled chylomicron triacylglycerol represents the serum triacylglycerol pool). The livers of recombinant HuTNF-alpha-treated rats and controls contained similar amounts of 14C-labeled lipids, but less [3H]cholesterol, suggesting that in recombinant HuTNF-alpha-treated rats, the liver took up chylomicron remnant particles enriched with triacylglycerol. Separation of the d less than 1.04 g/ml fraction of serum obtained from control and recombinant HuTNF-alpha treated rats by zonal ultracentrifugation revealed that in recombinant HuTNF-alpha-treated rats the lipoprotein particles were less lipolyzed than in controls. The secretion rate of [3H]triacylglycerol into the serum was determined 90 min after injection of [3H]palmitate albumin complex and Triton WR 1339. In recombinant HuTNF-alpha-treated rats, the secretion of [3H]triacylglycerol into plasma was 48% higher than in controls. It is suggested that the increase in lipoprotein lipase activity of heart and diaphragm resulted from an indirect effect of TNF. It is concluded that the increase in serum triacylglycerol in the recombinant HuTNF-alpha-treated rats is due mainly to an increased secretion of triacylglycerol by the liver. Impaired lipolysis, probably due to a fall in hepatic lipase could also contribute to the rise in plasma triacylglycerol.  相似文献   

3.
An accurate capillary gas chromatographic method using different internal standards for determining free fatty acids, cholesterol, cholesteryl esters, and triacylglycerols in plasma and other biological sources is described. It is designed to give information about species composition and, consequently, more detailed information about changes in lipid metabolism of patients suffering from metabolic disorders. After plasma extraction the lipids, except phospholipids, are directly examined without any further derivatization. For free fatty acid determination the programmed temperature vaporizer (PTV) injector was heated from 40 degrees C (sample introduction) to 190 degrees C. In a second gas chromatographic run the PTV-injector system was heated from 60 degrees C (sample introduction) to 400 degrees C, enabling the determination of free cholesterol, cholesteryl esters, and triacylglycerol species, differing in the number of carbon atoms. Evaluation of the values obtained resulted in coefficients of variation (%) of 1.0-2.8, 2.0, 1.29-2.24, and 2.8, for free fatty acid standards, plasma free fatty acids, cholesterol and cholesteryl ester standards, and plasma total cholesterol, respectively. Free fatty acids, cholesterol, and cholesteryl esters were not influenced by storage of plasma at -24 degrees C up to 4 days prior to extraction. The results of the gas chromatographic method and the enzymatic methods correlated well. Determination by gas chromatography yielded higher total cholesterol and lower triacylglycerol values than those values obtained by enzymatic methods.  相似文献   

4.
Effects of fat ingestion on high density lipoprotein profiles in human sera   总被引:2,自引:0,他引:2  
Serum concentrations of triacylglycerol, apolipoprotein A-I, apolipoprotein A-II, HDL2, and HDL3 were determined in sera of nine normolipidemic adult males, just before and 3, 5, and 8 hr after ingestion of 250 ml of cream (100 g of triacylglycerol). In all individuals a rapid hypertriglyceridemic response was observed. Triacylglycerol concentrations increased from 624 +/- 124 mg/liter of serum to 1435 +/- 350 mg/liter of serum 3 hr after cream ingestion. In most individuals the hypertriglyceridemic response was followed by a decline in serum triacylglycerol concentration to below basic levels. As a result of cream ingestion, small but statistically highly significant increases in serum cholesterol and apolipoprotein A-I concentrations were observed that persisted till the end of the observation period. In most individuals a small rise in the apolipoprotein A-II concentration in serum was also present. Marked changes were observed in serum HDL as illustrated in the HDL absorption at 280 nm and cholesterol profiles obtained by single-spin rate-zonal density gradient ultracentrifugation of the sera. Due to a prominent increase in phospholipids (up to about 18%) and a smaller increase in protein (up to about 6%), flotation rates and concentrations of HDL2 as well as HDL3 increased. These changes in HDL subclass flotation characteristics and chemical composition are best explained by uptake of surface material from chylomicrons by existing HDL2 and HDL3 particles. The data do not support a previously proposed concept in which HDL3 is converted into HDL2 by uptake of surface remnants formed during catabolism of triglyceride-rich lipoproteins.  相似文献   

5.
Serum lecithin:cholesterol acyltransferase (LCAT) was estimated by enzymatically measuring the decrease in unesterified cholesterol after incubation of serum with liposomes. A high-performance liquid chromatography (HPLC) study showed the uptake of the lipids of liposomes by serum high density lipoprotein. Of all the examined liposomes prepared from cholesterol and various synthetic phosphatidylcholines, liposomes with dimyristoylphosphatidylcholine (DMPC) were found to be the most reactive in the LCAT reaction. When serum was used as an enzyme source, addition of purified apolipoprotein A-I, which is known to be an endogenous activator of LCAT, to the assay mixture resulted in a slight decrease in enzyme activity. Using DMPC-cholesterol liposomes as the substrate, the LCAT activities in 120 human sera showed a mean value of 485.4 +/- 64.6 nmol/hr per ml (mean +/- SD), which is 4.4- to 5.4-fold higher than the values obtained by self-substrate methods. LCAT activity was a linear function of the serum sample volume up to 670 nmol/hr per ml and coefficients of variation (CV) less than 4% were obtained under the standardized conditions. Moreover, when partially purified LCAT was added to various heat-inactivated sera, the activity was efficiently recovered. These results suggest that this method is sensitive, reproducible, and not greatly influenced by serum components.  相似文献   

6.
The present study was undertaken to evaluate quantitatively the turnover of serum triacylglycerol (triglyceride) in the starved rat and to determine whether serum triacylglycerol recycled to liver contributes a significant fraction of the total hepatic triacylglycerol turnover. Serum was labelled in vitro with [3H]trioleoylglycerol (glycerol [3H]trioleate) to provide uniform labelling of all lipoprotein species. By using the curves describing disappearance of isotope from serum and its appearance in liver, rate constants for movement of triacylglycerol out of serum (0.29 min-1) and the uptake of serum triacylglycerol by liver (0.22 min-1) were calculated. The total rate of movement (flux) of triacylglycerol in these processes, the product of rate constant and serum pool size, was calculated to be 0.39 and 0.29 mg/min per 100 g body wt. respectively. A model is postulated for whole-body triacylglycerol metabolism consistent with the present data as well as most observations in the literature. From the model it can be predicted that: (1) the entire turnover of liver triacylglycerol in the starved rat can be accounted for on the basis of contributions from serum non-esterified fatty acid and serum triacylglycerol; (2) the entire turnover of the serum triacylglycerol pool can be accounted for quantitatively on the basis of contributions from intestine and liver; (3) the release rate for triacylglycerol from liver should be 0.34 to 0.35 mg/min per 100 g body wt.; (4) triacylglycerol synthesized by liver from non-esterified fatty acid of serum and by intestine can account quantitatively for the irreversible disposal rate of triacylglycerol from serum.  相似文献   

7.
Flow-injection enzymatic analysis for glycerol and triacylglycerol   总被引:2,自引:0,他引:2  
A flow-injection enzymatic analytical system was developed for determination of glycerol and triacylglycerol based on enzymatic reactions in capillary followed by electrochemical detection. The hydrogen peroxide produced from the enzyme reaction was monitored by a platinum-based electrochemical probe. Different immobilization strategies on silica support were studied. The best and most effective configuration found for the measurement of glycerol and triacylglycerols in this system was the tandem connection of a lipase column and a silica-fused capillary column coimmobilized with glycerokinase (GK) and glycerol-3-phosphate oxidase (GPO). Lipase helps the breakdown of triacylglycerol to yield free fatty acids and glycerol, while glycerokinase catalyzes the adenosine-5-triphosphate-dependent phosphorylation of glycerol to yield alpha-glycerol phosphate, which can subsequently be oxidized by 3-glycerol phosphate oxidase to produce hydrogen peroxide. Response-surface methodology (RSM) was applied to optimize the proposed system for glycerol. Experiment settings were designed by central composite design to investigate the combined effects of pH, flow rate, reaction temperature, and ATP concentration on collected signals. The fitted model, per RSM, showed that the optimum conditions of the system are 2 mM ATP in 0.1 M carbonate buffer (pH 11.0), flow rate of 0.18 mL/min, temperature of 35 degrees C, 20 microL of sample injection, and applied voltage of 0.650 V. The proposed biosensing system using lipase, GK, and GPO exhibited a flow-injection analysis peak response of 2.5 min and a detection limit of 5 x 10(-5) M glycerol (S/N = 3) with acceptable reproducibility (CV < 4.30%). It also had linear working ranges from 10(-4) to 10(-2) M for glycerol and from 10(-3) to 10(-2) M for triacylglycerol. The capillary enzyme reactor was stable up to 2 months in continuous operation, and it was possible to analyze up to 15 samples per hour. The present biosensing system holds promise for on-line detection of triacylglycerol in serum and glycerol content in fermented products.  相似文献   

8.
The study included 69 women taking a desogestrel (n = 30)- or gestodene (n = 39)-containing low-dose combined oral contraceptive for at least 3 months. Group size was calculated to detect a difference in mean values of 80% of 1 standard deviation (alpha = 0.05, beta = 0.1). Seven serum samples were obtained up to 4 h, and 1 sample 24 h, after drug intake on 1 day between the 10th and the 21st day of the cycle. The concentrations of sex-hormone-binding globulin (SHBG), corticoid-binding globulin (CBG) and cortisol were measured in a 0- to 4-hour serum pool by radioimmunoassay. Ethinyl estradiol (EE2) levels were analyzed in single and pooled samples using anti-EE2-6 beta-carboxymethyloxime-bovine serum albumin antiserum. The area under the curves (AUC) up to 4 and 24 h and Cmax and tmax were evaluated. Statistical analysis (analysis of covariance) did not reveal a dependence of values on duration of treatment or day of cycle. Both treatments resulted in almost identical values for all parameters evaluated. The mean levels of SHBG, CBG and cortisol were in the range of 186-226 nmol/l, 89-93 mg/l and 280-281 micrograms/l, respectively. Mean maximum EE2 levels of 106-129 pg/ml were found 1.6-1.8 h after pill intake and AUC0-4 h accounted for 329-374 pg.h.ml-1. The recently reported differences in serum EE2 and CBG levels between two groups of 11 women each treated with desogestrel- and gestodene-containing pills, respectively, could not be confirmed.  相似文献   

9.
Rats treated with ethynyloestradiol have marked hypolipidaemia: serum cholesterol is decreased to 5%, triacylglycerol to 10% and phospholipid to 70% of control concentrations. Loss of serum cholesterol follows an exponential decay, with a half-life of 1.13±0.09 days. After 4 days of treatment, serum cholesterol concentrations remain relatively constant (ranging from 1 to 20mg/100ml) for at least 30 days. There is a concomitant 20-fold decrease in the d<1.21 fraction of serum proteins and a similar decrease in serum apolipoproteins as measured by sodium dodecyl sulphate/10%-polyacrylamide-gel electrophoresis. The activity of hepatic microsomal acyl-CoA–cholesterol O-acetyltransferase (EC 2.3.1.26) was significantly increased by ethynyloestradiol treatment (P<0.05). This activation caused hepatic cholesteryl esters containing mainly C18:1 fatty acids to increase linearly as serum cholesterol concentrations decreased (r=0.9675, P<0.001). Triton WR-1339, a non-ionic detergent that inhibits lipoprotein catabolism, was used to estimate hepatic lipid secretion by measuring the increment in serum lipids after its administration. At 15h after Triton WR-1339 administration, serum cholesterol concentrations were increased equally in both control and ethynyloestradiol-treated rats. In contrast, the increment of serum triacylglycerol of treated rats was 40% of that found in control rats, indicating that ethynyloestradiol inhibits hepatic triacylglycerol secretion. Triton WR-1339 inhibited the oestrogen activation of hepatic microsomal acyl-CoA–cholesterol O-acyltransferase and restored hepatic cholesteryl ester concentrations to normal values. These data suggest that ethynyloestradiol and its pharmacological `antagonist' Triton WR-1339 alter hepatic triacylglycerol secretion via a mechanism associated with changes in hepatic cholesterol esterification.  相似文献   

10.
11.
A method for plant tissue digestion and triacylglycerol (TAG) extraction followed by transmethylation of TAGs to produce the fatty acid methyl esters (FAMEs) from small storage tissue samples is presented. The method allows the analysis of both TAGs and FAMEs from the same sample. Several reagent mixtures and different experimental conditions were tested on sliced sunflower seeds. The best results were obtained using a mixture that was 33.3% a solution of NaCl (0.17 M) in methanol and 66.6% heptane by volume. The TAGs in the heptane solution were transmethylated with a mixture containing methanol:toluene:dimethoxypropane:H(4)SO(2) (39:20:5:2, by vol). The method was also tested on other oil seed storage tissue (soybean) and fruit tissues from olive and acorn. In all cases, sunflower, soybean, olive, and acorn, the TAGs and FAMEs composition data obtained by this method were quite similar to data from a standard analysis method. In samples with high protein content, such as soybean and sunflower seeds, the TAG extraction was incomplete. The water content of fruit samples did not interfere with TAG extraction obtained by this method.  相似文献   

12.
A direct method has been described which makes possible a specific assay of progesterone in rat serum without extraction. Anti-progesterone serum was prepared in our laboratory by the immunization of three rabbits with 4-pregnen-3, 20-dione-3 CMO:BSA. This antiserum (Gunma OGP#1) displayed little or no cross reaction with 20 alpha-dihydroprogesterone (0.38%), pregnenolone (0.44%), 17 alpha hydroxypregnenolone (less than 0.1%), 20 beta hydroxyprogesterone (2.4%), 17 alpha hydroxyprogesterone (2.88%) or deoxycorticosterone (2.19%). The nonspecific inhibitory effect of serum was compensated for by adding progesterone-free serum to the standard curve tubes. The sensitivity of this assay was 1.1 pg/tube and serum progesterone could be measured by using as little as 1 microliter of serum. The working range of the standard curve was 1.25-2560 ng/ml. Under the conditions of this assay (1 microliter of serum per tube), interference from steroid binding proteins did not affect the sensitivity, precision or reliability of the assay. The intra-assay and inter-assay coefficients of variation were 5.5% and 8.7%, respectively, and the assay values correlated well with those obtained by the extraction method (R = 0.997, P less than 0.001). Analytical recovery indicates a close correlation between added and recovered progesterone concentrations (R = 0.992, P less than 0.001), and the recovery rate averaged 96%. Compared with the extraction method, the direct progesterone assay has the advantage of speed, precision and simplicity. The method described is particularly suitable for routine assays of progesterone in rat serum.  相似文献   

13.
Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45°C, and a restrictor temperature of 60°C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n=3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n=3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n=3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.  相似文献   

14.
The aim of the study was to develop and validate a feline urinary collection system for accurate 24 h urine output measurement and glomerular filtration rate (GFR) evaluation. We hypothesized that precise identification of urination time improves the accuracy of the collection system. In a group of nine cats, urinary volume and micturition times were repeatedly recorded for up to 48 h using purpose-built collection trays containing a temperature data logger. Collection time was determined both with and without using the data loggers on 22 occasions and agreement between estimated 24 h urine outputs obtained with the two calculation methods was evaluated. GFR was repeatedly measured by endogenous urinary creatinine clearance on three occasions. Twenty-four-hour urine output was measured in 98.5% of the attempted collections (300 cat-sampling days). Sensitivity and specificity of the detection system were 97.8% and 100%, respectively. Mean 24 h urine output was 12.4 ± 4.94 mL/kg/day and mean intra-cat between-days coefficient of variation (CV) was 16.6 ± 5.6% when data loggers were used. The absolute relative volume error between the two calculation methods ranged from 0% to 131%. Median absolute relative [interquartile range] error was 9.1% [3.25-19.8]. Bias was -1.3% and lower and upper limits of agreement were -39.7% and 35.2%, respectively. Mean estimated GFR was lower than previously reported with comparable urinary clearance methods (1.92 ± 0.37 mL/min/kg) and mean within-cat CV was 12 ± 6.9%. The system was simple in design, readily affordable, allowed normal micturition behaviour and reduced intra-animal variability in 24 h feline urine collection.  相似文献   

15.
Though surface electromyography (EMG) has been widely used in studies of occupational exposure, its precision in terms of the variance between-days and between-subjects has seldom been evaluated. This study aimed at such an evaluation. Six women performed three different work tasks: 'materials picking', 'light assembly', and 'heavy assembly', repeated on 3 different days. EMG was recorded from m. trapezius, m. infraspinatus and the forearm extensors. Normalisation was made to a maximal (MVE), and a submaximal (RVE), reference contraction. Variance components between days (within subjects) and between subjects were derived for the 10th, 50th and 90th percentiles, as well as for muscular rest parameters. For the task 'heavy assembly', the coefficient of variation between days (CV(BD)) was 8% for m. trapezius (right side, 50th percentile, MVE normalised values). Larger variabilities were found for m. infraspinatus (CV(BD) 15%), and the forearm extensors (CV(BD) 33%). Between-subjects variability (CV(BS)) was greater, 16% for m. trapezius and 57% for m. infraspinatus, 29% for the forearm extensors. RVE normalisation resulted in larger CV(BD), while reducing CV(BS). The between-days and between-subjects variability may be used to optimise sampling strategy, and to assess the bias in epidemiological studies. The bias caused by measurement procedures per se is acceptable.  相似文献   

16.
A solid-phase extraction method using Drug Test-1 column containing chemically modified silica as a solid support for sample clean up and reversed phase ion-paired high-pressure liquid chromatography method have been developed for the simultaneous determination of nicotine and its metabolite cotinine from the urine samples. Mobile phase was consisted of acetate buffer (containing 0.03 M sodium acetate and 0.1 M acetic acid) pH 3.1 and acetonitrile (78:22% (v/v)) containing 0.02 M sodium octanosulfonate as an ion pair agent. pH of the mobile phase was adjusted to 3.6 with triethylamine for better resolution and to prevent peak tailing. The linearity was obtained in the range of 0.5-10 microg/ml concentrations of nicotine and cotinine standards. The correlation coefficients were 0.998 for cotinine and 0.999 for nicotine. The recoveries were obtained in the range of 79-97% with average value of 85% for nicotine and in the range of 82-98% with average value of 88% for cotinine. The limit of detection was 2 ng/ml for cotinine and 5 ng/ml for nicotine with 2 ml urine for extraction, calculated by taking signal to noise ratio 10:3. The intra-day co-efficient of variation (CV) were <4 and 7% and inter-day CV were <9 and 7% for nicotine and cotinine, respectively. The method was applied to the urine samples of tobacco harvesters, who suffer from green tobacco sickness (GTS) to check the absorption of nicotine through dermal route during the various processes of tobacco cultivation due to its good reproducibility and sensitivity.  相似文献   

17.
A total of 25 apparently healthy adults (13 men and 12 women), 29.5 years (SD = 3.6 years) of age, served as subjects in a 24-h study conducted in Barcelona, Spain, in the spring of 1990. The group had a homogeneous pattern of meals, activity, and behavior. Six blood samples were collected at 4-h intervals over a single 24-h period beginning at 10:00 h. The oral temperature was measured at 2-h intervals to facilitate an independent biological time reference for the local population being studied. The serum concentration of 12 enzymes of clinical interest were measured in each sample: creatine kinase, creatine kinase 2, alanine aminotransferase, aspartate aminotransferase, γ-glutamyltransferase, alkaline phosphatase, cholinesterase, lactate dehydrogenase, lactate dehydrogenase 1, 5′-nucleotidase, pancreatic α-amylase, and triacylglycerol lipase. We supposed that all experimental data obtained for a quantity came from a single “hypothetical subject” that represented the central tendency of the population and then these data were analyzed for circadian rhythm by single cosinor. A statistically significant circadian rhythm was detected in all quantities studied (p ≤ 0.05) except for serum concentrations of pancreatic α-amylase and triacylglycerol lipase. The maximum daily rhythmic variation was ~ 10% (interval, 6–14%) for all quantities studied except pancreatic α-amylase (2.6%). This rhythmic variation is greater than the analytical variation except for 5′-nucleotidase and pancreatic α-amylase. The acrophases for the quantities studied (except that of triacylglycerol lipase) coincide with times near those of the oral temperature acrophase (18:01 local time). The results of this study will doubtless contribute to further documentation of the structure of the human circadian timing system and to establishment of time-qualified reference intervals for a defined group of subjects.  相似文献   

18.
Summary The applicability of the Electro-Ultra-Filtration (EUF) method in soil analyses was studied. The reproducibilities of the amounts of soil extracts, of ion concentrations in the extracts and of the distribution of cations and anions over the cathode and anode extracts by use of fully automatic EUF equipment were tested. The degree of variability among replicates was expressed as coefficient of variation (CV) and as the highest percentual divergence of an individual analytical measurement from the mean (L). The extraction volumes of five replicates of six different soils were found to vary between 1.1–7.1% with an average of 3.8%, as CV and between 1.5–11.3% as L. The reproducibility of desorbed P in the anode extract varied between 2.7–31.7% with an average of 8.7%, as CV and between 3.2–37.9% as L. Corresponding values for CV and L of K desorbed varied between 1.3–13.9% and 1.6–23.8%, respectively. Variations among replicates of desorbed P were especially high in the first 1–2 sub-fractions of a total of seven fractions in a single extraction run. Low K concentrations in the extract had a slightly negative influence on the reproducibility of K desorption. Furthermore, it was found that a portion of the cations is collected in the anode extract and a portion of the anions in the cathode extract, especially at the beginning of an extraction run. Pooling of anode and cathode extracts before analysis is therefore recommended.  相似文献   

19.
Some parameters of hepatic function and morphology were studied to compare germfree (GF) and conventional (CV) BALB/c mice. The levels of lipid peroxide (LPO) and aniline-hydroxylase (AH) activity in the livers and the serum total cholesterol (TC), triglyceride (TG) and phospholipid (PL) were significantly lower in GF than in CV 8-week-old mice. There were no significant differences in the histology and lectin-histochemistry of the livers in the GF and CV mice. On the other hand, in ex-GF mice which were induced by housing 4-week-old GF mice together with age-matched CV mice, the levels of LPO and AH activity in the liver and the serum TC, TG and PL contents increased rapidly within the first week and then approached values almost identical to those in CV mice 4 weeks later (i.e. at 8 weeks of age). The histologic picture of the liver was similar among the GF, CV and ex-GF mice.  相似文献   

20.
This paper reports the development and validation of a methodology for the low-level quantification of melamine and cyanuric acid in limited samples of rat serum. The methodology, based upon ion-exchange solid phase extraction (SPE) and ultra-performance liquid chromatography (UPLC) coupled with electrospray tandem mass spectrometry (MS/MS) in multiple reaction monitoring (MRM) mode, relies on the use of stable isotope-labeled internal standards and requires only 15 μL samples of serum. The method provides a recovery of 80-110% of melamine with a signal suppression of ca. 55%, and a recovery of 50-90% of cyanuric acid with a signal suppression ca. 40-60%, affording lower limits of quantification (LLOQ) for melamine or cyanuric acid of, respectively, 5 ppb (mean accuracy 109%; CV=4.9%) and 10 ppb (mean accuracy 96%; CV=8.6%). The small sample requirements, excellent sensitivity, accuracy and precision, and high-throughput (5 min of instrument run time) make this methodology optimal for toxicokinetic or exposure assessments studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号