首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
P Fach  M R Popoff 《Applied microbiology》1997,63(11):4232-4236
A duplex PCR procedure was evaluated for the detection of Clostridium perfringens in food and biological samples and for the identification of enterotoxigenic strains. This method uses two sets of primers which amplify in the same reaction two different DNA fragments simultaneously: the 283-bp C. perfringens phospholipase C gene fragment and the 426-bp enterotoxin gene fragment. Internal primers within the two primer sets confirmed the specificity of the method by DNA-DNA hybridization with the PCR products. No cross-reaction was observed with other Clostridium species or with other bacteria routinely found in food. The detection level was approximately 10(5) C. perfringens cells per g of stool or food sample. When overnight enrichment culture was used, 10 C. perfringens cells per g was detected in 57 artificially contaminated food samples. The duplex PCR is a rapid, sensitive, and reliable method for the detection and identification of enterotoxigenic C. perfringens strains in food samples. A slide latex agglutination test was also evaluated as a rapid, simple technique for the detection of C. perfringens enterotoxin in stool samples.  相似文献   

2.
鼠伤寒沙门氏菌多重PCR检测方法的研究   总被引:1,自引:0,他引:1  
分别根据沙门氏菌16S rRNA、质粒毒力基因spvC、致病基因invB、fimA序列设计4对引物,对沙门氏菌株及非沙门氏株菌基因组DNA进行多重PCR检测。结果该方法能检测出6.3×102 个cfu/ml纯培养的沙门氏菌,人工染菌食品模拟检测结果显示,熟鸡肉初始含菌量为17cfu/g、全脂奶粉为11cfu/g、生牛肉为13.6cfu/g,经过8h增菌,PCR检测为阳性。该体系能鉴定产生多种毒力因子的沙门氏菌,特异性强、敏感性高,为检测和鉴定沙门氏菌株提供了一个新方法。  相似文献   

3.
A real-time PCR assay using non-patented primers and a TaqMan probe for the detection and quantification of Salmonella spp. is presented. The assay is based on an internationally validated conventional PCR system, which was suggested as a standard method for the detection of Salmonella spp. in the FOOD-PCR project. The assay was sensitive and specific. Consistent detection of 9.5 genome equivalents per PCR reaction was achieved, whereas samples containing an average of 0.95 genome equivalents per reaction were inconsistently positive. The assay performed equally well as a commercially available real-time PCR assay and allowed sensitive detection of Salmonella spp. in artificially contaminated food. After enrichment for 16 h in buffered peptone water (BPW) or universal pre-enrichment broth (UPB) 2.5 CFU/25 g salmon and minced meat, and 5 CFU/25 g chicken meat and 25 ml raw milk were detected. Enrichment in BPW yielded higher numbers of CFU/ml than UPB for all matrices tested. However, the productivity of UPB was sufficient, as all samples were positive with both real-time PCR methods, including those containing less than 300 CFU/ml enrichment broth (enrichment of 5 CFU/25 ml raw milk in UPB).  相似文献   

4.
The AG-9600 AmpliSensor Analyzer is an automated fluorescence-based system for detection of polymerase chain reaction (PCR) products. The principle of the AmpliSensor PCR assay involves amplification-mediated disruption of a fluorogenic DNA signal duplex (AmpliSensor) that is homologous to a target sequence within a 284-bp amplified fragment of the Salmonella invA gene. Since the assay is homogenous, the data can be obtained by direct measurement of fluorescence of the amplification mixture. The accumulation of the amplified product, reflected by the fluorescence index, is monitored cycle by cycle by the AG-9600 Analyzer. The detection limit of the assay was less than 2 colony-forming units (cfu) per PCR reaction using a pure culture of Salmonella typhimurium. In post-spiking experiments in which Salmonella was added to the overnight pre-enriched samples (chicken carcass rinses, ground beef, ground pork and raw milk), the detection limit of the assay was 2–6 cfu per PCR reaction. In pre-spiking experiments in which Salmonella was added to the samples prior to overnight pre-enrichment, the detection limit was less than 3 cfu per 25 g or 25 ml of food. The assay was up to 2 orders of magnitude more sensitive than detection by ethidium bromide-stained agarose gel electrophoresis. To further evaluate assay performance, 54 naturally contaminated chicken carcass rinses, 65 raw milk and six ground pork samples were tested in the study. Thirty-eight Salmonella- positive samples confirmed by the Modified Semi-solid Rappaport-Vassiliadis (MSRV) culture assay were found positive using the AmpliSensor assay. Two chicken carcass rinses found positive using the assay were MSRV-negative. In addition, relative quantification using the AmpliSensor assay was linear up to 3 logs of initial target concentration in artificially contaminated food samples.  相似文献   

5.
A rapid and sensitive PCR-hybridization procedure for detection of Salmonella serovars in food samples was developed. This method is based on three subsequent steps: (1) extraction of nucleic acids from a 2 ml aliquot of the pre-enrichment medium used for the conventional culture method after 6 h of incubation at 37 degrees C; (2) amplification with primers selected from the sequences of invE and invA genes; (3) Southern blot and hybridization with a biotin labeled oligonucleotide probe. The entire procedure requires 30 h. The PCR-hybridization assay was able to detect as little as 50 fg of purified chromosomal DNA of S. typhimurium and 0.2 cfu g-1 of an artificially contaminated food sample. Of 245 food samples analyzed by culture and PCR-hybridization, 20 were positive by both methods and 16 were positive by PCR-hybridization only. None of the 209 PCR-negative samples tested positive by culture. The sensitivity, specificity, alpha and beta error values of the results of the PCR-hybridization procedure, compared with those of culture, were 100, 92.9, 0 and 7.1%, respectively. These results indicate that a short pre-enrichment and PCR-hybridization could be used as a screening test for the detection of Salmonella in food samples.  相似文献   

6.
A multiplex PCR assay was devised and compared with standard conventional methods for quality evaluation of pharmaceutical raw materials and finished products with low levels of microbial contamination. Samples which were artificially contaminated with <10 colony forming units of Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Salmonella species and possibly contaminated samples were incubated for 16 h with different enrichment media. Primers that deduce 559 bp fragment of the 16S rRNA gene was employed in amplifying E. coli species, similarly invasion protein gene with 275 bp fragment size was used as target for detecting Salmonella spp., in case of S. aureus a 461 bp amplicon from m-RNA nuclease gene, and an 709 bp fragment from oprL gene was used for amplifying P. aeruginosa. The detection limits for artificially contaminants by multiplex PCR was 1 CFU/g, where as in case of conventional method the detection limit was >2 CFU/g. Similarly, when tested with possibly contaminated samples, 35% were detected for E. coli, Salmonella spp., S. aureus and P. aeruginosa species with multiplex PCR, while only 21% were detected with standard conventional microbial methods. Multiplex PCR assay provides sensitive and reliable results and allows for the cost-effective detection of all four bacterial pathogens in single reaction tube.  相似文献   

7.
Direct quantification of mRNA from Salmonella sp. seeded for 1 h to soil and chicken manure was accomplished using magnetic capture hybridization as a purification technique. This detection strategy targeted the invA gene present in Salmonella sp. After cell lysis, phenol/chloroform purification and isopropanol precipitation, the RNA extract was combined with the hybridization probe conjugated to paramagnetic beads. After hybridization, the captured nucleic acids were released by denaturation and purified of contaminating DNA using DNase. The resulting RNA was of high purity and there was no need for dilution of the samples prior to RT-PCR. The developed procedure was reproducibly used to quantify Salmonella sp. in high organic agricultural soil. The detection limit for mRNA using ordinary quantitative PCR (employing SYBRgreen-based detection) was 5 x 10(4)Salmonella sp. cells per gram of soil. Chicken manure amended into soil (1:4 w/w) did not reduce the ability to quantify Salmonella sp. mRNA in soil. Pasteurization (65 degrees C, 30 min) of chicken manure containing Salmonella sp. dramatically reduced the detection of invA mRNA (requiring 42 qPCR cycles for detection versus 26 cycles in unpasteurized manure), presumably due to degradation of the invA mRNA in Salmonella sp. cells killed by pasteurization. By contrast, DNA-based qPCR still detected Salmonella sp. in the pasteurized manure. Thus, in this case using samples seeded with fresh Salmonella sp. the mRNA-based detection appears to be superior to minimizing false-positive detection which was prevalent with DNA-based qPCR.  相似文献   

8.
AIMS: To compare procedures for recovering template DNA from ground beef or chicken for polymerase chain reaction (PCR)-based detection of Salmonella. METHODS AND RESULTS: The primer set of ST11 and ST15 was utilized to amplify a 429-bp product from Salmonella serotype Typhimurium. Boiling and three commercial kits were evaluated for extracting DNA from pure suspensions and artificially contaminated ground beef and chicken. The detection sensitivity of the PCR assay for pure cultures was independent of the template preparation method (P=0.946). Boiling and GeneReleaser failed to detect Salm. Typhimurium at 4 x 106 cfu g(-1) in ground chicken. PrepMan Ultra and the high pure PCR template preparation kit facilitated reliable and sensitive detection of Salm. Typhimurium in two types of food. The sensitivities were approx. 4 x 103 cfu g(-1). When spiked samples were enriched in peptone water for 6 h, an initial inoculum of 1 cfu g(-1) was detectable. CONCLUSIONS: Four template DNA preparation methods differed in performance with respect to the type of samples tested. SIGNIFICANCE AND IMPACT OF THE STUDY: Template DNA for the PCR detection of pathogenic bacteria, such as Salmonella in meat and poultry, could be effectively obtained using a simple rapid method such as the commercially available PrepMan Ultra kit.  相似文献   

9.
A slot blot enzyme-linked immunosorbent assay, using monoclonal antibodies specific only for Salmonella paratyphi A, to detect S. paratyphi A contamination in raw prawns has been established. When artificially contaminated prawn samples were tested. S. paratyphi A contamination could be identified correctly within 20 h. No false positives from samples artificially contaminated by other microorganisms were obtained. The sensitivity was such that as few as 1 S. paratyphi A organism per g of raw prawn could be detected. Therefore, the assay constituted a promising test for the rapid and specific detection of S. paratyphi A in prawns.  相似文献   

10.
AIMS: Evaluation of iQ-Check PCR Salmonella for Salmonella detection in artificially and naturally contaminated food and environmental field samples. METHODS AND RESULTS: Artificially contaminated samples (poultry meat and ground red meat) subjected to cold- and freeze-stress, and 120 naturally contaminated samples (swabs and meat) were tested for Salmonella using the diagnostic semi-solid Salmonella medium (DIASALM) method, the Vidas assay and the iQ-Check PCR assay after 24 h enrichment in buffered peptone water. CONCLUSIONS: Both the iQ-Check PCR and the Vidas assay provide a rapid and user friendly screening method for detection of Salmonella. False negative samples were obtained for the inoculated samples using both the iQ-Check PCR assay and the Vidas method when Salmonella cells were severely stressed. In total 45 of 120 naturally contaminated field samples showed Salmonella positive using the DIASALM method. The agreement percentage with the DIASALM method was respectively 92% for the iQ-Check PCR and 95% for the Vidas method. SIGNIFICANCE AND IMPACT OF THE STUDY: False-negative samples were obtained for the inoculated samples using both the iQ-Check PCR assay and the Vidas method when Salmonella cells were severely stressed, e.g. freezing at -18 degrees C for 7 days. Of the 120 naturally contaminated field samples 45 showed Salmonella positive using the DIASALM method. The agreement percentage with the DIASALM method was 92% for the iQ-Check PCR and 95% for the Vidas method respectively.  相似文献   

11.
A robust duplex 5' nuclease (TaqMan) real-time PCR was developed and in-house validated for the specific detection of Salmonella enterica subspecies enterica serovar Enteritidis in whole chicken carcass rinses and consumption eggs. The assay uses specifically designed primers and a TaqMan probe to target the Prot6e gene located on the S. Enteritidis specific 60-kb virulence plasmid. As an internal amplification control to monitor Salmonella DNA in the sample, a second primer/TaqMan probe set detects simultaneously the Salmonella specific invA gene. The assay identified correctly 95% of the 79 Salmonella Enteritidis strains tested comprising 19 different phage types. None of the 119 non-Enteritidis strains comprising 54 serovars was positive for the Prot6e gene. The assay detection probability was for 10(2) or more genome equivalents 100% and for 10 equivalents 83%. A pre-PCR sample preparation protocol including a pre-enrichment step in buffered peptone water, followed by DNA extraction was applied on low levels of artificially contaminated whole chicken carcass rinses and eggs from hens as well as 25 potentially naturally contaminated chickens. The detection limit was less than three CFU per 50 ml carcass rinse or 10 ml egg. The sensitivity and specificity compared to the traditional culture-based detection method and serotyping were both 100%. Twenty-five potentially naturally contaminated chickens were compared by the real-time PCR and the traditional cultural isolation method resulting in four Salmonella positive samples of which two were positive for the Prot6e gene and serotyped as S. Enteritidis. We show also that Salmonella isolates which have a rough lipopolysaccharide structure could be assigned to the serovar Enteritidis by the real-time PCR. This methodology can contribute to meet the need of fast identification and detection methods for use in monitoring and control measures programmes.  相似文献   

12.
A micro-enzyme-linked immunosorbent assay (micro-ELISA) using the Salmonella-TEK screen kit was tested for the detection of Salmonella spp. in pure cultures as well as in 30 artificially contaminated food samples and in 45 naturally contaminated food samples. Different raw, fleshy foods and processed foods were used as test products. The artificially contaminated minced meat samples were preenriched in buffered peptone water, and after incubation, different selective enrichment broths were tested. The micro-ELISA optical density values after enrichment and isolation of the different broths were very analogous. The quickest method to detect Salmonella spp. in different foods is to enrich them with Salmosyst broth, which reduces the total analysis time to 31 h. The Salmonella-TEK kit for Salmonella spp. provides a promising test for the detection of Salmonella antigens in food even when they are present at a low concentration (1 to 5 CFU/25 g). The cross-reaction of the anti-Salmonella antibodies, especially to other gram-negative bacteria, is nil.  相似文献   

13.
Salmonella-TEK, a rapid screening method for Salmonella species in food   总被引:3,自引:0,他引:3  
A micro-enzyme-linked immunosorbent assay (micro-ELISA) using the Salmonella-TEK screen kit was tested for the detection of Salmonella spp. in pure cultures as well as in 30 artificially contaminated food samples and in 45 naturally contaminated food samples. Different raw, fleshy foods and processed foods were used as test products. The artificially contaminated minced meat samples were preenriched in buffered peptone water, and after incubation, different selective enrichment broths were tested. The micro-ELISA optical density values after enrichment and isolation of the different broths were very analogous. The quickest method to detect Salmonella spp. in different foods is to enrich them with Salmosyst broth, which reduces the total analysis time to 31 h. The Salmonella-TEK kit for Salmonella spp. provides a promising test for the detection of Salmonella antigens in food even when they are present at a low concentration (1 to 5 CFU/25 g). The cross-reaction of the anti-Salmonella antibodies, especially to other gram-negative bacteria, is nil.  相似文献   

14.
The use of latex agglutination tests for determining Campylobacter species   总被引:1,自引:0,他引:1  
A comparison was made between three commercially available latex agglutination tests for the detection of Campylobacter. All tests showed clear agglutination with pure cultures of several Campylobacter strains in both the spiral and coccoid form. The Microscreen test was able to detect 10 times less cells than the Campyslide and Meritec tests. The latex tests were also applied to enrichment broth cultures of chicken products. Sixty-nine per cent of the Campylobacter positive enrichment broth cultures were positive with the Microscreen test. The Meritec test detected 63% of the positive samples. The Campyslide test detected only 15% of the positive samples and often showed non-specific agglutination.  相似文献   

15.
The aim of this study was to examine the usefulness of latex test for detection of Salmonella in raw ground meat . Five hundred and fifty samples of meat were examined, including 368 samples artificially contaminated with S. enteritidis and S. typhimurium. Samples for latex test were also derived from classical microbiological culture (2 ml) which was run in parallel. Coincidence of positive results obtained in latex test with positive results in microbiological method was 7.6% to 15.3% (after introductory multiplication) and from 38.2% to 73.9% (after selective multiplication). There was no bacteriological confirmation for 7 samples (3.9%) positive in latex test. Ground meat environment and its bacterial flora have no qualitative influence on a result of latex test; the detection of Salmonella takes place if there is a sufficient concentration of somatic antigens of these microorganisms in a tested sample. However, these factors as well as a method od preparation of bacterial culture have influence on the sensitivity of latex test. In the light of this study it seems possible to use latex test for selection of samples. Positive samples could be eliminated from further bacteriological examination. The further studies are necessary involving other types of food products and studies on optimalisation of preparation of samples for latex test are also required.  相似文献   

16.
AIMS: To compare different analytical methods for detecting Salmonella in Dermanyssus gallinae. METHODS AND RESULTS: The detection limit of three Salmonella detection methods [Vitek immunodiagnostic assay (VIDAS) Salmonella immuno-concentration/immunoassay, FTA filter-based PCR, and Salmonella detection and identification medium (SM ID) preceded by a pre-enrichment step] was evaluated by crushing mites in serial dilutions of pure cultures of Salmonella enterica ssp. Enterica serotype Enteritidis. Each method was then compared for its ability to detect Salmonella in artificially contaminated mites. In 105 mites artificially engorged with Salm. Enteritidis-contaminated blood, Salmonella was isolated from 68 samples of the samples cultured on SM ID and tests were positive for Salmonella using FTA filter-based PCR and VIDAS in 77 and 65 samples, respectively. Using SM ID as our reference method, specificities and sensitivities were 97% and 94% and 73% and 98.5% for VIDAS and PCR, respectively. CONCLUSIONS: Each method allowed the detection of Salmonella in contaminated mites and is usable for screening mites. PCR is more sensitive but less specific than VIDAS for detecting Salmonella. SIGNIFICANCE AND IMPACT OF THE STUDY: This is the first time that the VIDAS has been used to detect pathogens in vectors. The development of analytical methods for Salmonella detection in mites is a necessary step in the study of the role of D. gallinae as a vector of salmonellae and to check the contamination of D. gallinae in poultry facilities.  相似文献   

17.
A polymerase chain reaction (PCR) was developed for the detection of Clostridium botulinum type A, a cause of human botulism. A two primer set and an oligonucleotide detection probe were used to specifically detect Cl. botulinum type A neurotoxin gene (BoNT/A). After 40 cycles of amplification, detection of a 798 bp amplified DNA fragment was carried out by agarose gel electrophoresis and Southern blot hybridization. This assay was able to detect 12.5 fg of purified target DNA or five bacteria per reaction. The sensitivity in artificially contaminated food samples after an 18 h enrichment step ranges from 10 to 103 bacteria per g according to the type of food samples. No cross-reactions were observed with the other Cl. botulinum toxinotypes and other bacteria found routinely in food. This PCR method may provide a suitable and rapid alternative to standard techniques for detection of Cl. botulinum type A in food samples.  相似文献   

18.
A 16S DNA targeted polymerase chain reaction (PCR) method specific for the detection of Salmonella isolates with various serotypes was developed. The primers used for such a PCR method were 16SF1 and 16SIII. 16SF1 is the reverse and complementary strand of 16SI which has been shown to be able to hybridize with Salmonella and Citrobacter spp. 16III on the other hand, is able to hybridize with Klebsiella and Serratia spp. in addition to Salmonella. Although 16SF1 and 16SIII were not specific to Salmonella only, when they were used as PCR primers, only the Salmonella isolates could be specifically detected. The interference from Citrobacter, Klebsiella and Serratia spp. could be prevented. None of the other non- Salmonella isolates including strains of the family of Enterobacteriaceae closely related to Salmonella would generate the false-positive reaction. When this PCR system was used for the detection of Salmonella cells artificially contaminated in food samples, results obtained were satisfactory. A detection limit of N × 100 cells per assay could be obtained.  相似文献   

19.
Here, hybridization assay of amplified products is described which detect Salmonella sp. from chicken fillets and other food homogenates within 24 h. This technique is composed of four steps : (1) sample is pre-enriched overnight in phosphate buffered peptone water ; (2) total DNA is extracted ; (3) a Salmonella spp. specific DNA target sequence is amplified by polymerase chain reaction ; (4) amplified products are captured by a probe covalently bound onto NH-CovalinkTM (Nunc, Danemark) microwells and detected by a chemiluminescent enzymatic reaction. This hybridization of amplified products was demonstrated as sensitive as their analysis on agarose gel. Compared to a bacteriological method for Salmonella spp. detection, its specificity was estimated at 100% and its sensitivity was 93·2% from analysis of 207 naturally contaminated chicken fillets samples.  相似文献   

20.
食品中沙门氏菌分子检测靶点的筛选与评价   总被引:2,自引:1,他引:2  
[目的]发掘新的沙门氏菌分子检测靶点,筛选检测性能优秀的引物.[方法]利用BLAST程序比较沙门氏菌属内基因组DNA序列的同源性以及沙门氏菌与非沙门氏菌基因组DNA序列之间的特异性,发掘出100多个检测沙门氏菌属的特异性片段,并从中随机挑选出15个片段作为候选靶点,一共设计了27对引物(FS1~FS27),对它们的特异性、灵敏度加以评价,从中筛选检测性能最好的引物.[结果]在27对引物中,检测性能最优的引物为FS23,采用该引物对供试菌株的相应检测靶点进行PCR扩增,44株沙门氏菌都能扩增到一条492 bp特异性片段,而22株非沙门氏菌则不能扩增出这一特异性片段.以FS23为引物建立PCR方法检测猪霍乱沙门氏菌基因组DNA的灵敏度为11.9 fg/μL,细菌纯培养物灵敏度为4.9×102cfu/mL;用猪霍乱沙门氏菌人工污染牛奶样品,如果接种起始菌量为100 cfu/25 mL时,只需要增菌5 h,采用上述方法即能检测出沙门氏菌.[结论]引物FS23对应的基因序列是一个性能优良的新分子检测靶点,具备很高的特异性和灵敏性,能够广泛应用于食品中沙门氏菌的快速检测.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号