首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The primary stem stability is an essential factor for success of cementless hip stems. A correct choice of the stem geometry can improve the stem stability and, consequently, increase the life time of a hip implant. In this work, it is proposed a computational model for shape optimization of cementless hip stems. The optimization problem is formulated by the minimization of relative displacement and stress on bone/stem interface using a multi-criteria objective function. Also multiple loads are considered to incorporate several daily life activities. Design variables are parameters that characterize the geometry of selected cross sections, which are subject to geometric constraints to ensure a clinically admissible shape. The stem/bone set is considered a structure in equilibrium with contact conditions on interface. The contact formulation allows us to analyze different lengths of porous coating. The optimization problem is solved numerically by a steepest descent method. The interface stress and relative displacement are obtained solving the contact problem by the finite element method. Numerical examples are presented for a two-dimensional model of a hip stem, however, the formulation is general and can be applied to the three-dimensional case. The model gives indications about the relation between shape, porous coating and prosthesis stability.  相似文献   

2.
The primary stem stability is an essential factor for success of cementless hip stems. A correct choice of the stem geometry can improve the stem stability and, consequently, increase the life time of a hip implant. In this work, it is proposed a computational model for shape optimization of cementless hip stems. The optimization problem is formulated by the minimization of relative displacement and stress on bone/stem interface using a multi-criteria objective function. Also multiple loads are considered to incorporate several daily life activities. Design variables are parameters that characterize the geometry of selected cross sections, which are subject to geometric constraints to ensure a clinically admissible shape. The stem/bone set is considered a structure in equilibrium with contact conditions on interface. The contact formulation allows us to analyze different lengths of porous coating. The optimization problem is solved numerically by a steepest descent method. The interface stress and relative displacement are obtained solving the contact problem by the finite element method. Numerical examples are presented for a two-dimensional model of a hip stem, however, the formulation is general and can be applied to the three-dimensional case. The model gives indications about the relation between shape, porous coating and prosthesis stability.  相似文献   

3.
The long-term success of a cementless total hip arthroplasty depends on the implant geometry and interface bonding characteristics (fit, coating and ingrowth) and on stem stiffness. This study evaluates the influence of stem geometry and fitting conditions on the evolution and distribution of the bone–stem contact, stress and strain during and after the hip stem insertion, by means of dynamic finite element techniques. Next, the influence of the mechanical state (bone–stem contact, stress and strain) resulted from the insertion process on the stem initial resistance to subsidence is investigated. In addition, a study on the influence of bone–stem interface conditions (friction) on the insertion process and on the initial stem stability under physiological loading is performed. The results indicate that for a stem with tapered shape the contact in the proximal part of the stem was improved, but contact in the calcar region was achieved only when extra press-fit conditions were considered. Changes in stem geometry towards a more tapered shape and extra press fit and variation in the bone–stem interface conditions (contact amount and high friction) led to a raise in the total insertion force. A direct positive relationship was found between the stem resistance to subsidence and stem geometry (tapering and press fit), bone–stem interface conditions (bone–stem contact and friction interface) and the mechanical status at the end of the insertion (residual stress and strain). Therefore, further studies on evaluating the initial performance of different stem types should consider the parameters describing the bone–stem interface conditions and the mechanical state resulted from the insertion process.  相似文献   

4.
Hip resurfacing arthroplasty is an alternative to traditional hip replacement that can conserve proximal bone stock and has gained popularity but bone resorption may limit implant survival and remains a clinical concern. The goal of this study was to analyze bone remodelling patterns around an uncemented resurfacing implant and the influence of ingrowth regions on resorption. A computed tomography-derived finite element model of a proximal femur with a virtually implanted resurfacing component was simulated under peak walking loads. Bone ingrowth was simulated by six interface conditions: fully bonded; fully friction; bonded cap with friction stem; a small bonded region at the stem-cup intersection with the remaining surface friction; fully frictional, except for a bonded band along the distal end of the cap and superior half of the cap bonded with the rest frictional. Interface condition had a large influence on remodelling patterns. Bone resorption was minimized when no ingrowth occurred at the bone-implant interface. Bonding only the superior half of the cap increased bone resorption slightly but allowed for a large ingrowth region to improve secondary stability.  相似文献   

5.
The success of a total hip arthroplasty is strongly related to the initial stability of the femoral component and to the stress shielding effect. In fact, for cementless stems, initial stability is essential to promote bone ingrowth into the stem coating. An inefficient primary stability is also a cause of thigh pain. In addition, the bone adaptation after the surgery can lead to an excessive bone loss and, consequently, can compromise the success of the implant. These factors depend on prosthesis design, namely on material, interface conditions and shape. Although, surgeons use stems with very different geometries, new computational tools using structural optimization methods have been used to achieve a better design in order to improve initial stability and therefore, the implant durability. In this work, a multi-criteria shape optimization process is developed to study the relationship between implants performance and geometry. The multi-criteria objective function takes into account the initial stability of the femoral stem and the effect of stress shielding on bone adaptation after the surgery. Then, the optimized stems are tested using a concurrent model for bone remodeling and osseointegration to evaluate long-term performance. Additionally, the sensitivity to misalignments is analyzed, since femoral stems are often placed in varus or valgus position. Results show that the different criteria are contradictory resulting in different characteristics for the hip stem. However, the multi-criteria formulation leads to compromise solutions, with a combination of the geometric characteristics obtained for each criterion separately.  相似文献   

6.
Bone ingrowth into a porous surface is one of the primary methods for fixation of orthopaedic implants. Improved understanding of bone formation and fixation of these devices should improve their performance and longevity. In this study predictions of bone ingrowth into an implant porous coating were investigated using mechano-reculatory models. The mechano-regulatory tissue differentiation algorithm proposed by Lacroix et al., and a modified version that enforces a tissue differentiation pathway by transitioning from differentiation to bone adaptation were investigated. The modified algorithm resulted in nearly the same behavior as the original algorithm when applied to a fracture-healing model. The algorithms were further compared using micromechanical finite element model of a beaded porous scaffold. Predictions of bone and fibrous tissue formation were compared between the two algorithms and to clinically observed phenomena. Under loading conditions corresponding to a press-fit hip stem, the modified algorithm predicted bone ingrowth into approximately 25% of the pore space, which is similar to that reported in experimental studies, while the original algorithm was unstable. When micromotion at the bone-implant interface was simulated, 20 mum of transverse displacement resulted in soft tissue formation at the bone-implant interface and minimal bone ingrowth. In contrast, 10 and 5 mum of micromotion resulted in bone filling 40% of the pore space and a stable interface, again consistent with clinical and experimental observations.  相似文献   

7.
A simple and efficient numerical method for predicting the remodelling of adaptive materials and structures under applied loading was presented and implemented within a finite element framework. The model uses the trajectorial architecture theory of optimisation to predict the remodelling of material microstructure and structural organisation under mechanical loading. We used the proposed model to calculate the density distribution of proximal femur in the frontal plane. The loading considered was the hip joint contact forces and muscular forces at the attachment sites of the muscles to the bone. These forces were estimated from a separate finite element calculation using a heterogeneous three-dimensional model of the proximal femur. The density distributions obtained by this procedure has a qualitative similarity with in vivo observations. Solutions displayed the characteristic high-density channels that are evident in the Dual X-ray Absorptiometry scan. There is also evidence of the intramedullary canal, as well as low-density regions in the femoral neck. Several parametric studies were carried out to highlight the advantages of the proposed method, which includes fast convergence and low-computational cost. The potential applications of the proposed method in predicting bone structural remodelling in cancer are also briefly discussed.  相似文献   

8.
One of the crucial factors for short- and long-term clinical success of total hip arthroplasty cementless implants is primary stability. Indeed, motion at the bone–implant interface above 40 μm leads to partial bone ingrowth, while motion exceeding 150 μm completely inhibits bone ingrowth. The aim of this study was to investigate the effect of two cementless femoral stem designs with different lengths on the primary stability. A finite element model of a composite Sawbones® fourth generation, implanted with five lengths of the straight prosthesis design and four lengths of the curved prosthesis design, was loaded with hip joint and abductor forces representing two physiological activities: fast walking and stair climbing. We found that reducing the straight stem length from 146 to 54 mm increased the average micromotion from 17 to 52 μm during fast walking, while the peak value increased from 42 to 104 μm. With the curved stem, reducing length from 105 to 54 mm increased the average micromotion from 10 to 29 μm, while the peak value increased from 37 to 101 μm. Similar findings are obtained for stair climbing for both stems. Although the present study showed that femoral stem length as well as stem design directly influences its primary stability, for the two femoral stems tested, length could be reduced substantially without compromising the primary stability. With the aim of minimising surgical invasiveness, newer femoral stem design and currently well performing stems might be used with a reduced length without compromising primary stability and hence, long-term survivorship.  相似文献   

9.
Bone remodeling simulation is an effective tool for the prediction of long-term effect of implant on the bone tissue, as well as the selection of an appropriate implant in terms of architecture and material. In this paper, a finite element model of proximal femur was developed to simulate the structures of internal trabecular and cortical bones by incorporating quantitative bone functional adaptation theory with finite element analysis. Cementless stems made of titanium, two types of Functionally Graded Material (FGM) and flexible ‘iso-elastic’ material as comparison were implanted in the structure of proximal femur respectively to simulate the bone remodeling behaviors of host bone. The distributions of bone density, von Mises stress, and interface shear stress were obtained. All the prosthetic stems had effects on the bone remodeling behaviors of proximal femur, but the degrees of stress shielding were different. The amount of bone loss caused by titanium implant was in agreement with the clinical observation. The FGM stems caused less bone loss than that of the titanium stem, in which FGM I stem (titanium richer at the top to more HAP/Col towards the bottom) could relieve stress shielding effectively, and the interface shear stresses were more evenly distributed in the model with FGM I stem in comparison with those in the models with FGM II (titanium and bioglass) and titanium stems. The numerical simulations in the present study provided theoretical basis for FGM as an appropriate material of femoral implant from a biomechanical point of view. The next steps are to fabricate FGM stem and to conduct animal experiments to investigate the effects of FGM stem on the remodeling behaviors using animal model.  相似文献   

10.
A computational framework was developed to simulate the bone remodelling process as a structural topology optimisation problem. The mathematical formulation of the Level Set technique was extended and then implemented into a coronal plane model of the proximal femur to simulate the remodelling of internal structure and external geometry of bone into the optimal state. Results indicated that the proposed approach could reasonably mimic the major geometrical and material features of the natural bone. Simulation of the internal bone remodelling on the typical gross shape of the proximal femur, resulted in a density distribution pattern with good consistency with that of the natural bone. When both external and internal bone remodelling were simulated simultaneously, the initial rectangular design domain with a regularly distributed mass reduced gradually to an optimal state with external shape and internal structure similar to those of the natural proximal femur.  相似文献   

11.
The optimality of bone's internal architecture and its remodelling is investigated by applying topological optimisation. The os-calcis (heel bone) which is subject to a relatively simple loading environment was used as the test problem. The solution is compared with X-ray and CT images of the os-calcis and is demonstrated to agree favourably with the bone's typical trabecular orientation in the coronal plane. The optimality of bone remodelling is further investigated by applying a perturbation during optimisation which leads to a different optimum topology. This is compared with in-vivo experimental results from a model in which the same perturbation was applied. The findings indicate that there may exist more than one optimum state for the same mechanical condition and that structural optimisation is able to find these multiple states. It is therefore suggested that structural optimisation can be used to investigate the mechanisms of bone remodelling.  相似文献   

12.
Hip resurfacing demonstrates good survivorship as a treatment for young patients with osteoarthritis, but occasional implant loosening failures occur. On the femoral side there is radiographic evidence suggesting that the implant stem bears load, which is thought to lead to proximal stress shielding and adaptive bone remodelling. Previous attempts aimed at reproducing clinically observed bone adaptations in response to the implant have not recreated the full set of common radiographic changes, so a modified bone adaptation algorithm was developed in an attempt to replicate more closely the effects of the prosthesis on the host bone. The algorithm features combined implant–bone interface healing and continuum bone remodelling. It was observed that remodelling simulations that accounted for progressive gap filling at the implant–bone interface predicted the closest periprosthetic bone density changes to clinical X-rays and DEXA data. This model may contribute to improved understanding of clinical failure mechanisms with traditional hip resurfacing designs and enable more detailed pre-clinical analysis of new designs.  相似文献   

13.
A computational framework was developed to simulate the bone remodelling process as a structural topology optimisation problem. The mathematical formulation of the Level Set technique was extended and then implemented into a coronal plane model of the proximal femur to simulate the remodelling of internal structure and external geometry of bone into the optimal state. Results indicated that the proposed approach could reasonably mimic the major geometrical and material features of the natural bone. Simulation of the internal bone remodelling on the typical gross shape of the proximal femur, resulted in a density distribution pattern with good consistency with that of the natural bone. When both external and internal bone remodelling were simulated simultaneously, the initial rectangular design domain with a regularly distributed mass reduced gradually to an optimal state with external shape and internal structure similar to those of the natural proximal femur.  相似文献   

14.
The objective of this paper is to identify the effects of materials of cementless femoral stem on the functional adaptive behaviors of bone.The remodeling behaviors of a two-dimensional simplified model of cementless hip prosthesis with stiff stem,flexible 'iso-elastic' stem,one-dimensional Functionally Graded Material (FGM) stem and two-dimensional FGM stem for the period of four years after prosthesis replacement were quantified by incorporating the bone remodeling algorithm with finite element analysis.The distributions of bone density,von Mises stress,and interface shear stress were obtained.The results show that two-dimensional FGM stem may produce more mechanical stimuli and more uniform interface shear stress compared with the stems made of other materials,thus the host bone is well preserved.Accordingly,the two-dimensional FGM stem is an appropriate femoral implant from a biomechanical point of view.The numerical simulation in this paper can provide a quantitative computational paradigm for the changes of bone morphology caused by implants,which can help to improve the design of implant to reduce stress shielding and the risk of bone-prosthesis interface failure.  相似文献   

15.
Hip resurfacing demonstrates good survivorship as a treatment for young patients with osteoarthritis, but occasional implant loosening failures occur. On the femoral side there is radiographic evidence suggesting that the implant stem bears load, which is thought to lead to proximal stress shielding and adaptive bone remodelling. Previous attempts aimed at reproducing clinically observed bone adaptations in response to the implant have not recreated the full set of common radiographic changes, so a modified bone adaptation algorithm was developed in an attempt to replicate more closely the effects of the prosthesis on the host bone. The algorithm features combined implant-bone interface healing and continuum bone remodelling. It was observed that remodelling simulations that accounted for progressive gap filling at the implant-bone interface predicted the closest periprosthetic bone density changes to clinical X-rays and DEXA data. This model may contribute to improved understanding of clinical failure mechanisms with traditional hip resurfacing designs and enable more detailed pre-clinical analysis of new designs.  相似文献   

16.
After an initial phase of growth and development, bone undergoes a continuous cycle of repair, renewal and optimisation by a process called remodelling. This paper describes a novel mathematical model of the trabecular bone remodelling cycle. It is essentially formulated to simulate a remodelling event at a fixed position in the bone, integrating bone removal by osteoclasts and formation by osteoblasts. The model is developed to construct the variation in bone thickness at a particular point during the remodelling event, derived from standard bone histomorphometric analyses. The novelties of the approach are the adoption of a predator-prey model to describe the dynamic interaction between osteoclasts and osteoblasts, using a genetic algorithm-based solution; quantitative reconstruction of the bone remodelling cycle; and the introduction of a feedback mechanism in the bone formation activity to co-regulate bone thickness. The application of the model is first demonstrated by using experimental data recorded for normal (healthy) bone remodelling to predict the temporal variation in the number of osteoblasts and osteoclasts. The simulated histomorphometric data and remodelling cycle characteristics compare well with the specified input data. Sensitivity studies then reveal how variations in the model's parameters affect its output; it is hoped that these parameters can be linked to specific biochemical factors in the future. Two sample pathological conditions, hypothyroidism and primary hyperparathyroidism, are examined to demonstrate how the model could be applied more broadly, and, for the first time, the osteoblast and osteoclast populations are predicted for these conditions. Further data are required to fully validate the model's predictive capacity, but this work shows it has potential, especially in the modelling of pathological conditions and the optimisation of the treatment of those conditions.  相似文献   

17.
Previous investigations into the optimisation of internal plates have mostly focused on the material properties of the implant. In this work, we optimise the shape, size and placement of the plate for successfully minimising bone remodelling around the implant. A design optimisation algorithm based on strain energy density criterion, combined with the finite element analysis, has been used in this study. The main optimisation goal was to reduce this change and keep it close to the conditions of an intact femur. The results suggest that the anterolateral side of the bone would be the optimum location for the plate, as for the geometry, the optimum moves towards having a thick, wide and short plate. These important results could be directly applicable to orthopaedic surgeons treating a femur fracture with internal plates. Since the optimisation algorithm remains the same for any patient, this advancement provides the surgeon with a tool to minimise the post surgery remodelling by trying to maintain the natural structure of the bone.  相似文献   

18.
The clinical success of polished tapered stems has been widely reported in numerous long term studies. The mechanical environment that exists for polished tapered stems, however, is not fully understood. In this investigation, a collarless, tapered femoral total hip stem with an unsupported distal tip was evaluated using a 'physiological' three-dimensional (3D) finite element analysis. It was hypothesized that stem-cement interface friction, which alters the magnitude and orientation of the cement mantle stress, would subsequently influence stem 'taper-lock' and viscoelastic relaxation of bone cement stresses. The hypothesis that creep-induced subsidence would result in increases to stem-cement normal (radial) interface stresses was also examined. Utilizing a viscoelastic material model for the bone cement in the analysis, three different stem-cement interface conditions were considered: debonded stem with zero friction coefficient (mu=0) (frictionless), debonded stem with stem-cement interface friction (mu=0.22) ('smooth' or polished) and a completely bonded stem ('rough'). Stem roughness had a profound influence on cement mantle stress, stem subsidence and cement mantle stress relaxation over the 24-h test period. The frictionless and smooth tapered stems generated compressive normal stress at the stem-cement interface creating a mechanical environment indicative of 'taper-lock'. The normal stress increased with decreasing stem-cement interface friction but decreased proximally with time and stem subsidence. Stem subsidence also increased with decreasing stem-cement interface friction. We conclude that polished stems have a greater potential to develop 'taper-lock' fixation than do rough stems. However, subsidence is not an important determinant of the maintenance of 'taper-lock'. Rather subsidence is a function of stem-cement interface friction and bone cement creep.  相似文献   

19.
Bone ingrowth simulation for a concept glenoid component design   总被引:5,自引:0,他引:5  
Glenoid component loosening is the major problem of total shoulder arthroplasty. It is possible that uncemented component may be able to achieve superior fixation relative to cemented component. One option for uncemented glenoid is to use porous tantalum backing. Bone ingrowth into the porous backing requires a degree of stability to be achieved directly post-operatively. This paper investigates the feasibility of bone ingrowth with respect to the influence of primary fixation, elastic properties of the backing and friction at the bone prosthesis interface. Finite element models of three glenoid components with different primary fixation configurations are created. Bone ingrowth into the porous backing is modelled based on the magnitude of the relative interface micromotions and mechanoregulation of the mesenchymal stem cells that migrated via the bonded part of the interface. Primary fixation had the most influence on bone ingrowth. The simulation showed that its major role was not to firmly interlock the prosthesis, but rather provide such a distribution of load, that would result in reduction of the peak interface micromotions. Should primary fixation be provided, friction has a secondary importance with respect to bone ingrowth while the influence of stiffness was counter intuitive: a less stiff backing material inhibits bone ingrowth by higher interface micromotions and stimulation of fibrous tissue formation within the backing.  相似文献   

20.
The aim of this study was to demonstrate that external loading due to daily activities, including mastication, speech and involuntary open–close cycles of the jaw contributes to the internal architecture of the mandible. A bone remodelling algorithm that regulates the bone density as a function of stress and loading cycles is incorporated into finite element analysis. A three-dimensional computational model is constructed on the basis of computerised tomography (CT) images of a human mandible. Masticatory muscle activation involved during clenching is modelled by static analysis using linear optimisation. Other loading conditions are approximated by imposing mandibular flexure. The simulations predict that mandibular bone density distribution results in a tubular structure similar to what is observed in the CT images. Such bone architecture is known to provide the bone optimum strength to resist bending and torsion during mastication while reducing the bone mass. The remodelling algorithm is used to simulate the influence of edentulism on mandibular bone loss. It is shown that depending on the location and number of missing teeth, up to one-third of the mandibular bone mass can be lost due to lack of adequate mechanical stimulation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号