1.
A direct ELISA for plasma cortisol is described which is carried out in a standard 96 well microtitre plate. In this ELISA cortisol-thyroglobulin conjugate is immobilised to the microtitre plate and competes with cortisol in the standard or plasma sample for antibody binding sites. Following washing the rabbit cortisol antibody bound to immobilised cortisol is incubated with peroxidase labelled goat antirabbit IgG. Following further washing o-phenylenediamine is added, colour developed, and the plate read at 492 nm on a standard ELISA plate reader. This ELISA shows good agreement with RIA and its sensitivity, specificity and precision allow its use in the routine steroid laboratory.  相似文献   

2.
Monoclonal antibodies to pregnanediol-3-glucuronide were produced and characterized. One of three clones investigated provided antibody suitable for a direct urinary enzyme-linked immunosorbent assay (ELISA). The ELISA uses a pregnanediol-thyroglobulin conjugate adsorbed onto the wells of a standard 96-well microtiter plate. Pregnanediol-3-glucuronide in standards or diluted urine competes with the immobilized steroid for antibody-binding sites. After washing, mouse monoclonal antibody bound to the plate is probed with antimouse immunoglobulin peroxidase. After further washing, o-phenylenediamine substrate is added and, finally, the absorbance is read at 492 nm. The ELISA shows excellent performance and agreement with the previous gas chromatographic method. The ELISA is ideal for aiding the assessment of ovarian function in the routine laboratory.  相似文献   

3.
J G Lewis  K H Yeo  P A Elder 《Steroids》1986,47(6):365-372
An enzyme-linked immunosorbent assay (ELISA) for 11-deoxycortisol is described for the first time. 11-Deoxycortisol-thyroglobulin conjugate is adsorbed onto the wells of a 96-well ELISA plate and competes with 11-deoxycortisol in the standards or plasma extract for antibody binding sites. After washing, immobilized primary antibody is probed with peroxidase-labeled goat anti-rabbit IgG. The ELISA plate is further washed and o-phenylenediamine added, color developed and the absorbance read at 492 nm. The ELISA shows good agreement with our existing 11-deoxycortisol radioimmunoassay (RIA) and has similar specificity and performance which allow its use in the routine steroid laboratory for assessing pituitary adrenal function by the metyrapone test.  相似文献   

4.
An enzyme-linked immunofiltration assay (ELIFA) and a microtitre plate enzyme-linked immunosorbent assay (ELISA) were developed and compared for their ability to detect staphylococcal enterotoxin B (SEB). The double antibody capture format was used for both assays. Factors which improved the sensitivity of the ELIFA system were (1) addition of casein and thimerosal to the antigen dilution buffer; (2) addition of polyethylene glycol (MW 6000) to the detection and conjugate antibody dilution buffers; and (3) washing with diethanolamine buffer prior to addition of the substrate/chromogen. The ELIFA system had a turnaround time of approximately 1 h and a detection limit of 1 ng/mL of purified SEB. The ELISA had a total turnaround time of 21 h, or 3 h using plates pre-coated overnight with the capture antibody. The detection limit of the ELISA for purified SEB was 0.05 ng/mL. The detection limit of SEB in cheese samples spiked with purified enterotoxin and subjected to a simple extraction procedure was 1 ng/mL and 0.1 ng/mL of extract, with the ELIFA and the ELISA, respectively.  相似文献   

5.
An enzyme-linked immunosorbent assay (ELISA) of the "sandwich-type" for sex hormone binding globulin (SHBG) has been developed. A rabbit anti-SHBG antibody (RAb) is immobilized to the microtitre plate. After incubation with standards and samples a second monospecific rabbit anti-SHBG antibody, labelled with alkaline phosphatase is added (RAb). Following further washing substrate is added, colour developed and the plate read at 405 nm wavelength on a standard ELISA plate reader. The assay is not influenced by the presence of steroids at the binding site, and shows good agreement to SHBG binding capacity assay and commercially available IRMA. Its sensitivity, specificity and precision allows its use in the routine laboratory. The SHBG ELISA has been used to measure SHBG concentrations in sera of normal men, women, pregnant women, and women receiving high-dose medroxyprogesterone acetate as a treatment of metastatic breast cancer.  相似文献   

6.
A single extraction fixed antigen enzyme-linked immunosorbent assay (ELISA) that can be completed in less than 24 h is described for the measurement of medroxyprogesterone acetate (MPA) in plasma. MPA is covalently coupled to bovine thyroglobulin and passively adsorbed in guanidine hydrochloride to a standard 96-well microtitre plate where it competes with MPA in the extracted plasma sample for goat anti-MPA. Antibody binding to the solid phase is determined via binding of a horse-radish peroxidase second antibody which reacts colorimetrically with its substrate. The reaction is stopped by addition of 1.25 M H2SO4 and absorbance read at 492 nm. All steps except for sample addition and extraction can be performed on an automatic ELISA processing machine. The assay is sensitive, specific and precise, with intra- and inter-assay coefficients of variation of less than 10 and 15%, respectively. Assay sensitivity is 0.08 ng/ml. The assay follows established methodology for other assays in this laboratory which assists standardization, cost structure and sample throughput and thus is a useful alternative to radioimmunoassays for the determination of MPA in plasma.  相似文献   

7.
Cortisol mouse monoclonal antibodies were produced and characterized. Of the four clones studied, supernatant from one clone (A2), compared with other cortisol monoclonal antibodies, showed minimal cross-reactivity to other C21 steroids and was suitable for the direct determination of cortisol in plasma by enzyme-linked immunosorbent assay using a standard 96-well microtiter plate. The enzyme-linked immunosorbent assay uses the immobilized antigen approach, in which cortisol in plasma samples or standards competes with immobilized steroid for antibody-binding sites. After washing, the cortisol antibody bound to the wells of the microtiter plate is detected with antimouse immunoglobulin conjugated to horseradish peroxidase. Following further washing, o-phenylenediamine substrate is added. The enzyme-linked immunosorbent assay is robust and semiautomated. The mean +/- SD recovery from plasma was 97% +/- 6%. Precision studies on three different plasma pools showed mean coefficients of variation of 7.6% and 8.6% for within- and between-assay variation, respectively. The satisfactory performance criteria allow its use in the routine laboratory.  相似文献   

8.
New filter assay methods are presented for quantitating both cytoplasmic and nuclear forms of the estrogen receptor protein. These methods exploit the strong adsorption of this protein to glass-fiber filters, which appears to occur without loss of steroid binding affinity. A “direct assay protocol” is described that detects only unfilled (nonliganded) estrogen binding sites. In addition, a convenient “exchange assay protocol” has been developed that detects, in addition, those receptors present whose binding sites have already bound nonradioactive estradiol. For the exchange assay, an extract containing receptor is adsorbed to a filter, which is washed free of unbound steroid and then equilibrated for a prolonged period with an excess volume of buffer containing radioactive estradiol. After brief washing in steroid-free buffer, the radioactivity adsorbed to the filter is measured to determine the amount of receptor present. These assays can be used at either 4 or 23°C, over a broad range of salt concentrations. The background of nonspecific binding is extremely low, due in part to the almost negligible affinity of free estradiol for the glass-fiber support.  相似文献   

9.
Indirect competitive enzyme-linked immunosorbent assays (ELISAs) that can be used to quantify several types of small, bioactive molecules, including peptides, steroids, and cyclic nucleotides, are described. The assays require no special expertise to perform, and the sensitivities are very high, equally or exceeding what is commonly achieved in radioimmunoassay (RIA). The molecule to be assayed or a synthetic derivative is coupled to a protein carrier (= conjugate). The conjugate is adsorbed to the wells of a microtiter plate where it is bound by antibody in inverse proportion to free hapten in a sample or standard. Bound antibody is then quantified with enzyme-labeled anti-immunoglobulin and appropriate substrate. The assay of peptides is illustrated for the sulfated cholecystokinin octapeptide, in which an ED50 of 20 fmol (2 x 10(-10) M in 100 microliters assay volume) is attained. The ED50's and slopes of the dose-response curves in the steroid and cyclic nucleotide ELISAs are compared with those parameters obtained earlier by RIA using the same antisera. This comparison indicates that a steroid, ecdysone, can be quantified with no apparent participation of the bridging group of the conjugate in the competitive assay. Furthermore, the ED50's in the ecdysone assays (ecdysone 2 beta, 3 beta, 14 alpha, 22R, 25-pentahydroxy-5 beta-cholest-7-en-6-one, 7.7 fmol; 20-hydroxyecdysone, 16 fmol) are 19- to 38-fold lower for ELISA than for RIA. In the cyclic nucleotide assay, the bridge of a cAMP conjugate (homologous with the bridge of the immunogen) decreases the slope of the dose-response curve. This effect is minimized by the use of short incubations with anti-cAMP.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
J G Lewis  N J Longley  P A Elder 《Steroids》1999,64(4):259-265
Four monoclonal antibodies to human sex hormone-binding globulin were raised and characterized. Three of the four antibodies recognised different antigenic determinants on SHBG. Two of the distinct antibodies were useful for Western blotting and recognized a major 48 kDa band in human plasma as well as a 46 kDa minor component. Carbohydrate residues do not form part of the antigenic determinants of these two antibodies, although one of these showed increased signal following removal of N-linked oligosaccharides. Some of the antibodies were selected to form a basis of a same-day, non-competitive, enzyme-linked immunosorbent assay (ELISA) for SHBG in plasma. The assay employs a purified IgG2a SHBG monoclonal antibody adsorbed to the wells of a microtitre plate. After blocking any further adsorption to the plate, standards or diluted patient samples were added for a 5-h incubation at room temperature, after which the plate was washed and antibody-bound SHBG was detected with an anti-SHBG IgG1 monoclonal antibody followed by peroxidase-labeled antimouse-IgG1 and o-phenylenediamine substrate. The assay correlated well with an existing 2-day ELISA for SHBG in plasma using polyclonal antibodies and also correlated with a dihydrosterone (DHT) ligand-binding assay. The monoclonal antibody-based ELISA shows excellent performance characteristics and is unaffected by added testosterone or estradiol.  相似文献   

11.
The use of hydroxyapatite to absorb antibody-bound steroid and thus separate free and antibody-bound steroid during radioimmunoassay has been examined using three steroid antisera (to testosterone, to 17-hydroxyprogesterone and to estradiol-17beta). For all three antisera studied the separation was shown to be independent of length of time in contact with hydroxyapatite (up to 1h); temperature variations from 4 degrees -37 degrees and pH over the range 4.9-8.0. The presence of protein affected the absorption of antibody-bound steroid but this effect could be overcome by the addition of increasing amounts of hydroxyapatite. Further increase in the amount of hydroxyapatite added had no effect on the separation of free and bound steroid. Sodium phosphate buffers of molarity greater than 0.01M eluted antibody-bount steroid from hydroxyapatite, but Tris-HC1 buffers up to molarities of 0.1 M had no effect. Hydroxyapatite when used as a dry powder had the same effects as suspensions. No effect on the cross-reactivities of the antisera used could be demonstrated when hydroxyapatite was used and plasma testosterone assays on 22 plasma samples using hydroxyapatite gave essentially the same results as assays on the plasma using a coated-tube assay. Hydroxyapatite can also be successfully pumped along small bore plastic tubing without settling and can thus be used in automated immunoassay systems.  相似文献   

12.
In this report we describe an enzyme-linked immunosorbent assay (ELISA) for the quantitation of abscisic acid (ABA) in plant extracts. A microtitration plate is coated with an ABA-protein complex. The ABA, standard or sample, is then added to each well with a limiting quantity of rabbit anti-ABA antibodies. During the following incubation period, antibodies bind either to free or to bound ABA on the plates. After washing, bound antibodies are indirectly labelled in two steps by the means of biotinylated goat antirabbit immunoglobulin-G antibodies which act as a link between rabbit anti-ABA antibodies and an avidin-alkaline phosphatase complex. The relative enzyme activity bound is measured spectrophotometrically. The detection limit of this method is 5 pg ABA and the measuring range extends to 10 ng. Gas-liquid-chromatography controls, with an electron capture detector, show a good correlation with ELISA results obtained using extracts of Lycopersicon esculentum, Nicotiana tabacum and Pseudotsuga menziesii samples purified by high-performance liquid chromatography. This provides a good argument for the accuracy of the immunoenzymatic method. The indirect labelling of antibodies, with the avidin-biotin amplifying system, should make this technique suitable for the quantitation of other plant growth substances against which specific antibodies are available.Abbreviations ABA abscisic acid - BSA bovine serum albumin - ELISA enzyme-linked immunosorbent assay - GLC gas liquid chromatography - HPLC high-performance liquid chromatography - IgG Immunoglobulin G - PBS phosphate-buffered saline  相似文献   

13.
Current immunoassays for the measurement of leukotriene B(4) (LTB(4)) typically utilize an enzyme-linked immunosorbent assay (ELISA) format that requires multiple incubations and washing steps and often expensive immunoassay kits. We have developed a bead-based, mix and read, indirect fluorescence-linked immunosorbent assay utilizing fluorometric microvolume assay technology (FMAT). The assay employs a monoclonal anti-LTB(4) antibody-coated onto goat antimouse antibody coupled polystyrene beads and an AlexaFluor-647-coupled LTB(4) ligand. Because the FMAT measurement is made only in the portion of the well volume containing the settled beads coated with AF647-LTB(4), the free label in the solution is not measured. Similarly, substances present in plasma that interfere with other immunoassays are largely ignored. The assay is robust (Z=0.8; S/N=250) and can be measured in the presence of relatively high concentrations of dimethyl sulfoxide or serum. It is inexpensive (<0.10 dollars/assay) and amenable to robotics and has a sensitivity comparable to that of the most sensitive ELISA assays; the concentration of LTB(4) giving 50% inhibition (IC(50)) was ca. 55pg/ml. Cross-reactivity in the FMAT assay was comparable to that of the ELISA assay with significant cross-reactivity found only with 20-hydroxy LTB(4) and 12-epi LTB(4). Measurements of LTB(4) determined by FMAT were equivalent to those measured by standard ELISA in samples of ionophore-stimulated human neutrophils or whole blood.  相似文献   

14.
An enzyme-linked lectin assay (ELLA) has been developed to detect specific carbohydrate units on the surface of unfixed cells. The assay may be read in standard ELISA plate readers, since the cell-bound enzyme-lectin conjugate is specifically eluted from the cells prior to development of the conjugate. ELLA, when read in an enzyme-linked immunosorbent assay (ELISA) plate reader, allows better detection and relative quantitation of specific surface carbohydrate units than is possible by standard immunofluorescence with fluorescein-conjugated lectins.  相似文献   

15.
Three easy and rapid microtiter plate assays for determining phage sensitivity of lactococci and enterococci have been developed. In the microlysis assay, the degree of sensitivity was measured on the basis of the ability of the bacterial cells to grow in the presence of various concentrations of phage and to effect a color change of an acid-base indicator as a result of acid production. Two assays that specifically measure phage adsorption to bacterial cells have been developed on the basis of the enzyme-linked immunosorbent assay (ELISA) technique. In the direct phage adsorption ELISA, adsorption of phage particles to cells immobilized onto microtiter plate wells was measured using specific anti-phage antibody. In the competitive phage adsorption ELISA, phage adsorption was assayed by allowing phage to compete with specific antibody binding to the bacterial cell surface. All three assays were quantifiable photometrically.  相似文献   

16.
Immuno-polymerase chain reaction (immuno-PCR) combines the specificity of antibodies with the amplification power of PCR to detect low levels of proteins. Here, we describe the development of a 384-well immuno-PCR method that uses streptavidin coated on a PCR plate to capture complexes of biotinylated capture antibody, antigen, and DNA-labeled detection antibody. Unbound molecules are removed by a wash step using a standard plate washer. Antibody–DNA molecules in bound complexes are then detected directly on the plate using real-time PCR. Circulating human vascular endothelial growth factor concentrations measured by this method correlated with measurements obtained from enzyme-linked immunosorbent assay (ELISA). Using this method, we developed an assay for human epidermal growth factor-like domain 7 (EGFL7), an extracellular matrix-bound angiogenic factor. EGFL7 is expressed at a higher level in certain cancers, although endogenous EGFL7 concentrations have not been reported. Our 384-well EGFL7 immuno-PCR assay can detect 0.51 pM EGFL7 in plasma, approximately 16-fold more sensitive than the ELISA, utilizing the same antibodies. This assay detected EGFL7 in lysates of non-small-cell lung cancer and hepatocellular carcinoma cell lines and also hepatocellular carcinoma, breast cancer, and ovarian cancer tissues. This 384-well immuno-PCR method can be used to develop high-throughput biomarker assays.  相似文献   

17.
Glutathione S-transferase genetically fused with an affinity peptide tag, PS19 (RAFIASRRIKRP) having a specific affinity for a hydrophilic polystyrene (PS) surface, was preferentially immobilized on a hydrophilic PS (phi-PS) plate without suffering from interference by coexisting protein molecules. Furthermore, rabbit IgG chemically conjugated with a peptide, KPS19R10, in which (10)Lys in PS19 was replaced with Arg and one Lys residue was added at the N-terminus as a coupling site for glutaraldehyde, showed a higher immobilization affinity to the phi-PS plate than that conjugated with the PS19 peptide. On the basis of these findings, the use of a phi-PS plate and peptide tag-linked ligand proteins permitted a one-step or two-step enzyme-linked immunosorbent assay (ELISA) to be achieved, resulting in a substantial reduction in operational time compared with the conventional ELISA method using a hydrophobic PS (pho-PS) plate, while maintaining a high sensitivity. Furthermore, the sensitivity was increased to a greater extent compared to the conventional ELISA meihod when the one-step ELISA was applied to the detection of bovine insulin in a sandwich mode, due to the reduced number of washing and incubation steps. The method proposed here would be a versatile method for use in various ELISA techniques such as sandwich and competitive ELISAs using an antigen, an antibody and streptavidin that are genetically fused or chemically conjugated with the PS-specific affinity peptide as the ligand protein.  相似文献   

18.
In this paper we report on the evaluation of several procedures that allow for the repeated use of an antigen-coated, enzyme-linked immunosorbent assay (ELISA) plate for enzyme immunoassay (EIA). We have shown that antigen-coated ELISA plates that were incubated once with an aqueous solution containing 8 M urea, 2% sodium dodecyl sulfate and 2% mercaptoethanol, after an EIA, can be reused again for EIA without loss of antigenic capacity. Thus, in this procedure, after an EIA, the ELISA plates were washed once with the above solution and then in a buffer containing 20 mM Tris-HCl, pH 7.5, 0.1% Tween 20 and 500 mM NaCl. This washing protocol was shown to remove the primary antibody, enzyme-conjugated secondary antibody and substrate without removing the antigen from the ELISA plate microwells. Thus, an antigen-coated ELISA plate previously used for an assay could be reused. We tested this repeat ELISA (R-ELISA) procedure on high antigen-binding ELISA plates coated with two different plant virus proteins, a synthetic peptide, the p25/24 gag and the gp120 proteins of the human immuno-deficiency virus, or the staphylococcus enterotoxin protein. In each case tested, the procedure allowed for the repeated use of the same antigen-coated plates for EIA of the respective antibodies. This procedure should prove to be particularly valuable for mass screening of samples tested for HIV and other disease-causing agents.  相似文献   

19.
Noninvasive hormone assays provide a way to determine an animal's health or reproductive status without the need for physical or chemical restraint, both of which create unnecessary stress for the animal, and can potentially alter the hormones being measured. Because hormone metabolism is highly species‐specific, each assay must be validated for use in the species of interest. Validation of noninvasive steroid hormone assays has traditionally required the administration of relatively high doses of radiolabelled compounds (100 µCi or more of 14C labeled hormone) to permit subsequent detection of the excreted metabolites in the urine and feces. Accelerator mass spectrometry (AMS) is sensitive to extremely low levels of rare isotopes such as 14C, and provides a way to validate hormone assays using much lower levels of radioactivity than those traditionally employed. A captive Asian bull elephant was given 1 µCi of 14C‐testosterone intravenously, and an opportunistic urine sample was collected 2 hr after the injection. The sample was separated by HPLC and the 14C in the fractions was detected by AMS to characterize the metabolites present in the urine. A previously established HPLC protocol was used, which permitted the identification of fractions into which testosterone sulfate, testosterone glucuronide, and the parent compound testosterone elute. Results from this study indicate that the majority of testosterone excreted in the urine of the Asian bull elephant is in the form of testosterone sulfate. A small amount of testosterone glucuronide is also excreted, but there is no parent compound present in the urine at all. These results underscore the need for enzymatic hydrolysis to prepare urine samples for hormone assay measurement. Furthermore, they highlight the importance of proper hormone assay validation in order to ensure accurate measurement of the desired hormone. Although this study demonstrated the utility of AMS for safer validation of noninvasive hormone assays in nondomestic species, this methodology could also be applied to studies of nutrient metabolism and drug pharmakokinetics, both areas in great need of further study in wildlife species. Zoo Biol 29:760–766, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

20.
Application of theoretical considerations to the analysis of ELISA data   总被引:4,自引:0,他引:4  
Solid-phase immunoassays such as the ELISA are in routine use in many areas of biological research. Data from these assays are analyzed in a variety of ways, frequently without taking into account the immunochemical principles of the assay. The Reference Standard Method is often used and is suitable and convenient for obtaining concentration (or activity) values from the antigen-specific ELISA or spRIA, sandwich assays, and inhibition assays. The standard curve required for this method may be obtained by simple linear regression analysis of logarithmic or logitlogarithmic transformed data obtained from titration of the reference standard. The shape of the logarithmic plot of the reference standard provides information on the performance of the assay. Examining data from multiple dilutions of the samples is essential to assure that each titrates with the same slope as does the reference standard; the analysis routine must permit this comparison to be made. ELISANALYSIS is a program for the IBM PC which was developed to perform such analyses. It is presented here as a model, with sufficient information provided for the development of similar analytical routines by interested users. This approach to ELISA data analysis is presented as an alternative to complicated empirical curve-fitting systems and simple endpoint methods, which can be immunochemically misleading or, in some cases, even invalid. The consistent use of the described routines would encourage greater uniformity in the means of data interpretation and thereby enhance our understanding of immunobiology.  相似文献   