 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

This study exploits the speed benefits of echo-planar spectroscopic imaging (EPSI) to acquire lipid spectra of skeletal muscle. The main purpose was to develop a high-resolution EPSI technique for clinical MR scanner, to visualise the bulk magnetic susceptibility (BMS) shifts of extra-myocellular lipid (EMCL) spectral lines, and to investigate the feasibility of this method for the assessment of intra-myocellular (IMCL) lipids.

Methods

The study group consisted of six healthy volunteers. A two dimensional EPSI sequence with point-resolved spectroscopy (PRESS) spatial localization was implemented on a 3T clinical MR scanner. Measurements were performed by means of 64×64 spatial matrix and nominal voxel size 3×3×15 mm3. The total net measurement time was 3 min 12 sec for non-water-suppressed (1 acquisition) and 12 min 48 sec for water-suppressed scans (4 acquisitions).

Results

Spectra of the human calf had a very good signal-to-noise ratio and linewidths sufficient to differentiate IMCL resonances from EMCL. The use of a large spatial matrix reduces inter-voxel signal contamination of the strong EMCL signals. Small voxels enabled visualisation of the methylene EMCL spectral line splitting and their BMS shifts up to 0.5 ppm relative to the correspondent IMCL line. The mean soleus muscle IMCL content of our six volunteers was 0.30±0.10 vol% (range 0.18–0.46) or 3.6±1.2 mmol/kg wet weight (range: 2.1–5.4).

Conclusion

This study demonstrates that high-spatial resolution PRESS EPSI of the muscle lipids is feasible on standard clinical scanners.  相似文献   

2.

Introduction

The reproducibility of tractography is important to determine its sensitivity to pathological abnormalities. The reproducibility of tract morphology has not yet been systematically studied and the recently developed tractography contrast Tract Density Imaging (TDI) has not yet been assessed at the tract specific level.

Materials and Methods

Diffusion tensor imaging (DTI) and probabilistic constrained spherical deconvolution (CSD) tractography are performed twice in 9 healthy subjects. Tractography is based on common space seed and target regions and performed for several major white matter tracts. Tractograms are converted to tract segmentations and inter-session reproducibility of tract morphology is assessed using Dice similarity coefficient (DSC). The coefficient of variation (COV) and intraclass correlation coefficient (ICC) are calculated of the following tract metrics: fractional anisotropy (FA), apparent diffusion coefficient (ADC), volume, and TDI. Analyses are performed both for proximal (deep white matter) and extended (including subcortical white matter) tract segmentations.

Results

Proximal DSC values were 0.70–0.92. DSC values were 5–10% lower in extended compared to proximal segmentations. COV/ICC values of FA, ADC, volume and TDI were 1–4%/0.65–0.94, 2–4%/0.62–0.94, 3–22%/0.53–0.96 and 8–31%/0.48–0.70, respectively, with the lower COV and higher ICC values found in the proximal segmentations.

Conclusion

For all investigated metrics, reproducibility depended on the segmented tract. FA and ADC had relatively low COV and relatively high ICC, indicating clinical potential. Volume had higher COV but its moderate to high ICC values in most tracts still suggest subject-differentiating power. Tract TDI had high COV and relatively low ICC, which reflects unfavorable reproducibility.  相似文献   

3.

Background

The electronic nose (e nose) provides distinctive breath fingerprints for selected respiratory diseases. Both reproducibility and respiratory function correlates of breath fingerprint are poorly known.

Objectives

To measure reproducibility of breath fingerprints and to assess their correlates among respiratory function indexes in elderly healthy and COPD subjects.

Method

25 subjects (5 COPD patients for each GOLD stage and 5 healthy controls) over 65 years underwent e-nose study through a seven sensor system and respiratory function tests at times 0, 7, and 15 days. Reproducibility of the e nose pattern was computed. The correlation between volatile organic compound (VOC) pattern and respiratory function/clinical parameters was assessed by the Spearman''s rho.

Measurements and Main Results

VOC patterns were highly reproducible within healthy and GOLD 4 COPD subjects, less among GOLD 1–3 patients.VOC patterns significantly correlated with expiratory flows (Spearman''s rho ranging from 0.36 for MEF25% and sensor Co-Buti-TPP, to 0.81 for FEV1% and sensor Cu-Buti-TPP p<0.001)), but not with residual volume and total lung capacity.

Conclusions

VOC patterns strictly correlated with expiratory flows. Thus, e nose might conveniently be used to assess COPD severity and, likely, to study phenotypic variability. However, the suboptimal reproducibility within GOLD 1–3 patients should stimulate further research to identify more reproducible breath print patterns.  相似文献   

4.

Objective

To investigate if magnetic resonance spectroscopy (MRS) is the best Magnetic Resonance (MR)-based method when compared to gradient-echo magnetic resonance imaging (MRI) for the detection and quantification of liver steatosis in diabetic patients in the clinical practice using liver biopsy as the reference standard, and to assess the influence of steatohepatitis and fibrosis on liver fat quantification.

Methods

Institutional approval and patient consent were obtained for this prospective study. Seventy-three patients with type 2 diabetes (60 women and 13 men; mean age, 54±9 years) underwent MRI and MRS at 3.0 T. The liver fat fraction was calculated from triple- and multi-echo gradient-echo sequences, and MRS data. Liver specimens were obtained in all patients. The accuracy for liver fat detection was estimated by receiver operator characteristic (ROC) analysis, and the correlation between fat quantification by imaging and histolopathology was analyzed by Spearman''s correlation coefficients.

Results

The prevalence of hepatic steatosis was 92%. All gradient-echo MRI and MRS findings strongly correlated with biopsy findings (triple-echo, rho = 0.819; multi-echo, rho = 0.773; MRS, rho = 0.767). Areas under the ROC curves to detect mild, moderate, and severe steatosis were: triple-echo sequences, 0.961, 0.975, and 0.962; multi-echo sequences, 0.878, 0.979, and 0.961; and MRS, 0.981, 0.980, and 0.954. The thresholds for mild, moderate, and severe steatosis were: triple-echo sequences, 4.09, 9.34, and 12.34, multi-echo sequences, 7.53, 11.75, and 15.08, and MRS, 1.71, 11.69, and 14.91. Quantification was not significantly influenced by steatohepatitis or fibrosis.

Conclusions

Liver fat quantification by MR methods strongly correlates with histopathology. Due to the wide availability and easier post-processing, gradient-echo sequences may represent the best imaging method for the detection and quantification of liver fat fraction in diabetic patients in the clinical practice.  相似文献   

5.

Introduction

Studies have shown that fat lesions follow resolution of inflammation in the spine of patients with axial spondyloarthritis (SpA). Fat lesions at vertebral corners have also been shown to predict development of new syndesmophytes. Therefore, scoring of fat lesions in the spine may constitute both an important measure of treatment efficacy as well as a surrogate marker for new bone formation. The aim of this study was to develop and validate a new scoring method for fat lesions in the spine, the Fat SpA Spine Score (FASSS), which in contrast to the existing scoring method addresses the localization and phenotypic diversity of fat lesions in patients with axial SpA.

Methods

Fat lesions at pre-specified anatomical locations at each vertebral endplate (C2 lower-S1 upper) were assessed dichotomously (present/absent) on spine MRIs. Two readers independently evaluated MRIs obtained at two time points for 58 patients (Exercise 1), followed by optimization of scoring methodology and reader calibration. Thereafter, the same readers read 135 pairs of MRI scans (Exercise 2; including the 58 pairs from exercise 1 randomly mixed with 77 new pairs).

Results

In Exercise 2, the mean (SD) baseline FASSS score for the two readers was 22.5(29.6) and 21.1(28.0), respectively, and the FASSS change score was 4.2(10.6) and 6.0(12.2). Inter-reader reliability assessed as intra-class correlation coefficients (ICCs) for status and change scores were excellent (0.96 (95% CI (0.94 to 0.97)) and very good (0.86 (0.80 to 0.90)), respectively. The smallest detectable change (SDC) was 3.7 for the 135 patients. Good reliability of change scores was also observed for MRI scans conducted one year apart (ICC 0.74 (95% CI 0.44 to 0.89) and SDC 4.5). For the 58 MRI-pairs assessed in both exercises, inter-reader reproducibility for the total FASSS status score improved from very good (ICCs: 0.89 (95% CI: 0.81 to 0.93) in exercise 1 to excellent in exercise 2 (0.96 (0.93 to 0.98)), and improved substantially for the total change score (from 0.67 (0.51 to 0.80) to 0.83 (0.73 to 0.90).

Conclusions

FASSS meets essential validation criteria for quantification of a common structural abnormality in clinical trials of axial spondyloarthritis.  相似文献   

6.

Objective

Ultrasonographic studies have demonstrated transient reduction in spleen volume in relation to apnea diving. We measured spleen volume under various respiratory conditions by MR imaging to accurately determine the influence of ordinary breath holding on spleen volumetry.

Materials and Methods

Twelve healthy adult volunteers were examined. Contiguous MR images of the spleen were acquired during free breathing and during respiratory manipulations, including breath holding at the end of normal expiration, breath holding at deep inspiration, and the valsalva maneuver, and spleen volume was measured from each image set based on the sum-of-areas method. Acquisition during free breathing was performed with respiratory triggering. The duration of each respiratory manipulation was 30 s, and five sets of MR images were acquired serially during each manipulation.

Results

Baseline spleen volume before respiratory manipulation was 173.0 ± 79.7 mL, and the coefficient of variance for two baseline measures was 1.4% ± 1.6%, suggesting excellent repeatability. Spleen volume decreased significantly just after the commencement of respiratory manipulation, remained constant during the manipulation, and returned to the control value 2 min after the cessation of the manipulation, irrespective of manipulation type. The percentages of volume reduction were 10.2% ± 2.9%, 10.2% ± 3.5%, and 13.3% ± 5.7% during expiration breath holding, deep-inspiration breath holding, and the valsalva maneuver, respectively, and these values did not differ significantly.

Conclusions

Spleen volume is reduced during short breath-hold apnea in healthy adults. Physiological responses of the spleen to respiratory manipulations should be considered in the measurement and interpretation of spleen volume.  相似文献   

7.

Objective

The purpose of this study was to determine the accuracy and reliability of Frankfort horizontal plane identification using displays of multi-planar reconstructed MRI images, and propose it as a sufficiently stable and standardized reference plane for craniofacial structures.

Materials and Methods

MRI images of 43 subjects were obtained from the longitudinal population based cohort study SHIP-2 using a T1-weighted 3D sequence. Five examiners independently identified the three landmarks that form FH plane. Intra-examiner reproducibility and inter-examiner reliability, correlation coefficients (ICC), coefficient of variability and Bland-Altman plots were obtained for all landmarks coordinates to assess reproducibility. Intra-examiner reproducibility and inter-examiner reliability in terms of location and plane angulation were also assessed.

Results

Intra- and inter-examiner reliabilities for X, Y and Z coordinates of all three landmarks were excellent with ICC values ranging from 0.914 to 0.998. Differences among examiners were more in X and Z than in Y dimensions. The Bland–Altman analysis demonstrated excellent intra- as well as inter-examiner agreement between examiners in all coordinates for all landmarks. Intra-examiner reproducibility and inter-examiner reliability of the three landmarks in terms of distance showed mean differences between 1.3 to 2.9 mm, Mean differences in plane angulation were between 1.0° to 1.5° among examiners.

Conclusion

This study revealed excellent intra-examiner reproducibility and inter-examiner reliability of Frankfort Horizontal plane through 3D landmark identification in MRI. Sufficiently stable landmark-based reference plane could be used for different treatments and studies.  相似文献   

8.
Li M  Song Y  Cho N  Chang JM  Koo HR  Yi A  Kim H  Park S  Moon WK 《PloS one》2011,6(10):e25563

Background

Much research has been devoted to the development of new breast cancer diagnostic measures, including those involving high-resolution magic angle spinning (HR-MAS) magnetic resonance (MR) spectroscopic techniques. Previous HR-MAS MR results have been obtained from post-surgery samples, which limits their direct clinical applicability.

Methodology/Principal Findings

In the present study, we performed HR-MAS MR spectroscopic studies on 31 breast tissue samples (13 cancer and 18 non-cancer) obtained by percutaneous core needle biopsy. We showed that cancer and non-cancer samples can be discriminated very well with Orthogonal Projections to Latent Structure-Discriminant Analysis (OPLS-DA) multivariate model on the MR spectra. A subsequent blind test showed 69% sensitivity and 94% specificity in the prediction of the cancer status. A spectral analysis showed that in cancer cells, taurine- and choline-containing compounds are elevated. Our approach, additionally, could predict the progesterone receptor statuses of the cancer patients.

Conclusions/Significance

HR-MAS MR metabolomics on intact breast tissues obtained by core needle biopsy may have a potential to be used as a complement to the current diagnostic and prognostic measures for breast cancers.  相似文献   

9.

Background

Quantitative PCR (qPCR) is a workhorse laboratory technique for measuring the concentration of a target DNA sequence with high accuracy over a wide dynamic range. The gold standard method for estimating DNA concentrations via qPCR is quantification cycle () standard curve quantification, which requires the time- and labor-intensive construction of a standard curve. In theory, the shape of a qPCR data curve can be used to directly quantify DNA concentration by fitting a model to data; however, current empirical model-based quantification methods are not as reliable as standard curve quantification.

Principal Findings

We have developed a two-parameter mass action kinetic model of PCR (MAK2) that can be fitted to qPCR data in order to quantify target concentration from a single qPCR assay. To compare the accuracy of MAK2-fitting to other qPCR quantification methods, we have applied quantification methods to qPCR dilution series data generated in three independent laboratories using different target sequences. Quantification accuracy was assessed by analyzing the reliability of concentration predictions for targets at known concentrations. Our results indicate that quantification by MAK2-fitting is as reliable as standard curve quantification for a variety of DNA targets and a wide range of concentrations.

Significance

We anticipate that MAK2 quantification will have a profound effect on the way qPCR experiments are designed and analyzed. In particular, MAK2 enables accurate quantification of portable qPCR assays with limited sample throughput, where construction of a standard curve is impractical.  相似文献   

10.

Objective

The objective of this study was to evaluate the intra-examiner and inter-examiner reproducibility of paraspinal thermography using an infrared scanner.

Materials and Methods

The thermal functions of a commercially available infrared scanner (Insight Subluxation Station®) were evaluated for clinical reliability. Two practicing clinicians conducted the measures on 100 subjects. Intra class correlation coefficients (ICCs) and concordance correlation coefficients (CCCs) were calculated from the collected data.

Results

Mean bilateral paraspinal skin temperature was 89.78° F and ranged from 88.77° F to 91.43° F. Intra class correlation coefficients (ICCs) for agreement and consistency ranged from 0.959 to 0.976. Concordance correlation coefficients (CCCs) ranged from 0.783 to 0.859 with tight confidence intervals indicating robust estimates of these quantities.

Conclusion

This study revealed excellent intra-examiner and inter-examiner reproducibility of paraspinal thermography using a commercially available unit.  相似文献   

11.

Background

The brain biochemical changes of social anxiety have not been clarified although there have been a limited number of MR spectroscopic studies which utilized metabolite/creatine ratios. Present study aimed to explore the alteration of absolute metabolite concentration in social anxiety disorder using quantitative MR spectroscopy.

Materials and Methods

With a 3.0T MR scanner, single voxel MR spectroscopy (stimulated echo acquisition mode, TR/TE/TM = 2000/20/16 ms) was performed in the left dorsolateral prefrontal cortex and related regions of nine medication-free patients with social anxiety disorder and nine controls. Absolute metabolite concentration was calculated using tissue water as the internal reference and corrected for the partial volume of cerebrospinal fluid.

Results

In the left dorsolateral prefrontal cortex, the N-acetyl aspartate/creatine ratio of patients was significantly higher than that of controls, and this was due to the decrease of creatine concentration instead of the increase of N-acetyl aspartate concentration. Furthermore, the creatine concentration of the left dorsolateral prefrontal cortex was negatively correlated with the scores of Liebowitz social anxiety scale.

Conclusions

The alteration of creatine level in the left dorsolateral prefrontal cortex suggests abnormal energy metabolism and correlates with symptom severity in social anxiety disorder. And metabolite concentration is preferable to metabolite/creatine ratio for the investigation of individual, absolute metabolite changes in this region of social anxiety disorder.  相似文献   

12.

Background

Head and neck Magnetic Resonance (MR) Images are vulnerable to the arterial blood in-flow effect. To compensate for this effect and enhance accuracy and reproducibility, dynamic tracer concentration in veins was proposed and investigated for quantitative dynamic contrast-enhanced (DCE) MRI analysis in head and neck.

Methodology

21 patients with head and neck tumors underwent DCE-MRI at 3T. An automated method was developed for blood vessel selection and separation. Dynamic concentration-time-curves (CTCs) in arteries and veins were used for the Tofts model parameter estimations. The estimation differences by using CTCs in arteries and veins were compared. Artery and vein voxels were accurately separated by the automated method. Remarkable inter-slice tracer concentration differences were found in arteries while the inter-slice concentration differences in veins were moderate. Tofts model fitting by using the CTCs in arteries and veins produced significantly different parameter estimations. The individual artery CTCs resulted in large (>50% generally) inter-slice parameter estimation variations. Better inter-slice consistency was achieved by using the vein CTCs.

Conclusions

The use of vein CTCs helps to compensate for arterial in-flow effect and reduce kinetic parameter estimation error and inconsistency for head and neck DCE-MRI.  相似文献   

13.

Background

Current quantification methods for mass spectrometry (MS)-based proteomics either do not provide sufficient control of variability or are difficult to implement for routine clinical testing.

Results

We present here an integrated quantification (InteQuan) method that better controls pre-analytical and analytical variability than the popular quantification method using stable isotope-labeled standard peptides (SISQuan). We quantified 16 lung cancer biomarker candidates in human plasma samples in three assessment studies, using immunoaffinity depletion coupled with multiple reaction monitoring (MRM) MS. InteQuan outperformed SISQuan in precision in all three studies and tolerated a two-fold difference in sample loading. The three studies lasted over six months and encountered major changes in experimental settings. Nevertheless, plasma proteins in low ng/ml to low μg/ml concentrations were measured with a median technical coefficient of variation (CV) of 11.9% using InteQuan. The corresponding median CV using SISQuan was 15.3% after linear fitting. Furthermore, InteQuan surpassed SISQuan in measuring biological difference among clinical samples and in distinguishing benign versus cancer plasma samples.

Conclusions

We demonstrated that InteQuan is a simple yet robust quantification method for MS-based quantitative proteomics, especially for applications in biomarker research and in routine clinical testing.

Electronic supplementary material

The online version of this article (doi:10.1186/1559-0275-12-3) contains supplementary material, which is available to authorized users.  相似文献   

14.

Background

amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease that leads to death within a few years after diagnosis. Malnutrition and weight loss are frequent and are indexes of poor prognosis. Total body fat and fat distribution have not been studied in ALS patients.

Objectives

Our aim was to describe adipose tissue content and distribution in ALS patients.

Design

We performed a cross-sectional study in a group of ALS patients (n = 62, mean disease duration 22 months) along with age and gender matched healthy controls (n = 62) using a MRI-based method to study quantitatively the fat distribution.

Results

Total body fat of ALS patients was not changed as compared with controls. However, ALS patients displayed increased visceral fat and an increased ratio of visceral to subcutaneous fat. Visceral fat was not correlated with clinical severity as judged using the ALS functional rating scale (ALS-FRS-R), while subcutaneous fat in ALS patients correlated positively with ALS-FRS-R and disease progression. Multiple regression analysis showed that gender and ALS-FRS-R, but not site of onset, were significant predictors of total and subcutaneous fat. Increased subcutaneous fat predicted survival in male patients but not in female patients (p<0.05).

Conclusions

Fat distribution is altered in ALS patients, with increased visceral fat as compared with healthy controls. Subcutaneous fat content is a predictor of survival of ALS patients.  相似文献   

15.

Introduction

Low muscle mass secondary to disease and ageing is an important cause of excess mortality and morbidity. Many studies include a MR brain scan but no peripheral measure of muscle mass. We developed a technique to measure posterior neck muscle cross-sectional area (CSA) on volumetric MR brain scans enabling brain and muscle size to be measured simultaneously.

Methods

We performed four studies to develop and test: feasibility, inter-rater reliability, repeatability and external validity. We used T1-weighted MR brain imaging from young and older subjects, obtained on different scanners, and collected mid-thigh MR data.

Results

After developing the technique and demonstrating feasibility, we tested it for inter-rater reliability in 40 subjects. Intraclass correlation coefficients (ICC) between raters were 0.99 (95% confidence intervals (CI) 0.98–1.00) for the combined group (trapezius, splenius and semispinalis), 0.92 (CI 0.85–0.96) for obliquus and 0.92 (CI 0.85–0.96) for sternocleidomastoid. The first unrotated principal component explained 72.2% of total neck muscle CSA variance and correlated positively with both right (r = 0.52, p = .001) and left (r = 0.50, p = .002) grip strength. The 14 subjects in the repeatability study had had two MR brain scans on three different scanners. The ICC for between scanner variation for total neck muscle CSA was high at 0.94 (CI 0.86–0.98). The ICCs for within scanner variations were also high, with values of 0.95 (CI 0.86–0.98), 0.97 (CI 0.92–0.99) and 0.96 (CI 0.86–0.99) for the three scanners. The external validity study found a correlation coefficient for total thigh CSA and total neck CSA of 0.88.

Discussion

We present a feasible, valid and reliable method for measuring neck muscle CSA on T1-weighted MR brain scans. Larger studies are needed to validate and apply our technique with subjects differing in age, ethnicity and geographical location.  相似文献   

16.

Objective

The objectives of this study were to forecast epidemic peaks of typhoid and paratyphoid fever in China using the grey disaster model, to evaluate its feasibility of predicting the epidemic tendency of notifiable diseases.

Methods

According to epidemiological features, the GM(1,1) model and DGM model were used to build the grey disaster model based on the incidence data of typhoid and paratyphoid fever collected from the China Health Statistical Yearbook. Model fitting accuracy test was used to evaluate the performance of these two models. Then, the next catastrophe date was predicted by the better model.

Results

The simulation results showed that DGM model was better than GM(1,1) model in our data set. Using the DGM model, we predicted the next epidemic peak time will occur between 2023 to 2025.

Conclusion

The grey disaster model can predict the typhoid and paratyphoid fever epidemic time precisely, which may provide valuable information for disease prevention and control.  相似文献   

17.

Context

Hepatic steatosis, defined as increased hepatocellular lipid content (HCL), associates with visceral obesity and glucose intolerance. As exact HCL quantification by 1H-magnetic resonance spectroscopy (1H-MRS) is not generally available, various clinical indices are increasingly used to predict steatosis.

Objective

The purpose of this study was to test the accuracy of NAFLD liver fat score (NAFLD-LFS), hepatic steatosis index (HSI) and fatty liver index (FLI) against 1H-MRS and their relationships with insulin sensitivity and secretion.

Design, Setting and Participants

Ninety-two non-diabetic, predominantly non-obese humans underwent clinical examination, 1H-MRS and an oral glucose tolerance test (OGTT) to calculate insulin sensitivity and β-cell function. Accuracy of indices was assessed from the area under the receiver operating characteristic curve (AROC).

Results

Median HCL was 2.49% (0.62;4.23) and correlated with parameters of glycemia across all subjects. NAFLD-LFS, FLI and HSI yielded AROCs of 0.70, 0.72, and 0.79, respectively, and related positively to HCL, insulin resistance, fasting and post-load β-cell function normalized for insulin resistance. Upon adjustment for age, sex and HCL, regression analysis revealed that NAFLD-LFS, FLI and HSI still independently associated with both insulin sensitivity and β-cell function.

Conclusion

The tested indices offer modest efficacy to detect steatosis and cannot substitute for fat quantification by 1H-MRS. However, all indices might serve as surrogate parameters for liver fat content and also as rough clinical estimates of abnormal insulin sensitivity and secretion. Further validation in larger collectives such as epidemiological studies is needed.  相似文献   

18.

Purpose

To compare the reproducibilities of manual and semiautomatic segmentation method for the measurement of normalized cerebral blood volume (nCBV) using dynamic susceptibility contrast-enhanced (DSC) perfusion MR imaging in glioblastomas.

Materials and Methods

Twenty-two patients (11 male, 11 female; 27 tumors) with histologically confirmed glioblastoma (WHO grade IV) were examined with conventional MR imaging and DSC imaging at 3T before surgery or biopsy. Then nCBV (means and standard deviations) in each mass was measured using two DSC MR perfusion analysis methods including manual and semiautomatic segmentation method, in which contrast-enhanced (CE)-T1WI and T2WI were used as structural imaging. Intraobserver and interobserver reproducibility were assessed according to each perfusion analysis method or each structural imaging. Interclass correlation coefficient (ICC), Bland-Altman plot, and coefficient of variation (CV) were used to evaluate reproducibility.

Results

Intraobserver reproducibilities on CE-T1WI and T2WI were ICC of 0.74–0.89 and CV of 20.39–36.83% in manual segmentation method, and ICC of 0.95–0.99 and CV of 8.53–16.19% in semiautomatic segmentation method, repectively. Interobserver reproducibilites on CE-T1WI and T2WI were ICC of 0.86–0.94 and CV of 19.67–35.15% in manual segmentation method, and ICC of 0.74–1.0 and CV of 5.48–49.38% in semiautomatic segmentation method, respectively. Bland-Altman plots showed a good correlation with ICC or CV in each method. The semiautomatic segmentation method showed higher intraobserver and interobserver reproducibilities at CE-T1WI-based study than other methods.

Conclusion

The best reproducibility was found using the semiautomatic segmentation method based on CE-T1WI for structural imaging in the measurement of the nCBV of glioblastomas.  相似文献   

19.

Background

Analysis of exhaled breath condensate (EBC) is a non-invasive method for studying the acidity (pH) of airway secretions in patients with inflammatory lung diseases.

Aim

To assess the reproducibility of EBC pH for two commercially available devices (portable RTube and non-portable ECoScreen) in healthy controls, patients with asthma or COPD, and subjects suffering from an acute cold with lower-airway symptoms. In addition, we assessed the repeatability in healthy controls.

Methods

EBC was collected from 40 subjects (n = 10 in each of the above groups) using RTube and ECoScreen. EBC was collected from controls on two separate occasions within 5 days. pH in EBC was assessed after degasification with argon for 20 min.

Results

In controls, pH-measurements in EBC collected by RTube or ECoScreen showed no significant difference between devices (p = 0.754) or between days (repeatability coefficient RTube: 0.47; ECoScreen: 0.42) of collection. A comparison between EBC pH collected by the two devices in asthma, COPD and cold patients also showed good reproducibility. No differences in pH values were observed between controls (mean pH 8.27; RTube) and patients with COPD (pH 7.97) or asthma (pH 8.20), but lower values were found using both devices in patients with a cold (pH 7.56; RTube, p < 0.01; ECoScreen, p < 0.05).

Conclusion

We conclude that pH measurements in EBC collected by RTube and ECoScreen are repeatable and reproducible in healthy controls, and are reproducible and comparable in healthy controls, COPD and asthma patients, and subjects with a common cold.  相似文献   

20.