首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Because congestive heart failure (CHF) promotes ventricular fibrillation (VF), we compared VF in seven dogs with CHF induced by combined myocardial infarction and rapid ventricular pacing to VF in six normal dogs. A noncontact, multielectrode array balloon catheter provided full-surface real-time left ventricular (LV) endocardial electrograms and a dynamic color-coded display of endocardial activation projected onto a three-dimensional model of the LV. Fast Fourier transform (FFT) analysis of virtual electrograms showed no difference in peak or centroid frequency in CHF dogs compared with normals. The average number of simultaneous noncontiguous wavefronts present during VF was higher in normals (2.4 +/- 1.0 at 10 s of VF) than in CHF dogs (1.3 +/- 1.0, P < 0.005) and decreased in both over time. The wavefront "turnover" rate, estimated using FFT of the noncontiguous wavefront data, did not differ between normals and CHF and did not change over 5 min of VF. Thus the fundamental frequency characteristics of VF are unaltered by CHF, but dilated abnormal ventricles sustain fewer active wavefronts than do normal ventricles.  相似文献   

2.
Myocardium undergoes functional changes in the infarcted region primarily due to ischemia. Following myocyte functional alterations of the noninfarcted myocardium are caused by remodelling and hypertrophy. We have monitored and compared changes in the electrocardiographical (ECG) image after coronary artery occlusion (CAO, n=5) and intracoronary endothelin-1 (ET-1, n=3) administration during a 6-month period. In 3 dogs, the CAO was repeated 6 months after the first occlusion. Signal-averaged ECG (SA ECG) was recorded before the operation and 10 days, 1 month, 3 months and 6 months after myocardial infarction (MI). The modified Wigner distribution was used for spectrotemporal analysis of the SA ECG. Eight-hour Holter monitoring was performed in each dog before and after experimental MI. Spectrotemporal representations of the QRS complex were stabilized after the first 1-month period in the group of dogs after CAO. The same results were also observed after the repeated CAO. No arrhythmias were recorded 9 days after CAO. The spectrotemporal representations of the QRS complex after intracoronary ET-1 administration were not stabilized during the whole observed period. Very few arrhythmic events were recorded by Holter monitoring already 3 days after intracoronary ET-1 injection. Experimental MI induced by CAO caused a changed ECG image, which was stable from 1 month after MI induction till the end of the monitoring. However, the ECG image after ET-1 administration was not stable during the whole observed period. No arrhythmic events were recorded in either group 3 months postoperatively that could be caused by healthy myocardial status before the experimental MI induction. In clinical practice, however, ischemic heart disease usually precedes the MI. Arrhythmogenic substrate could thus be a consequence of combination of healthy status of the myocardium before MI and MI itself.  相似文献   

3.
The aim of the study was to establish a database for electrocardiographic parameters of Beagle dogs used for toxicological studies and to evaluate the influence of supplier, sex, heart rate (HR) and body position for electrocardiogram (ECG) recording on ECG parameters. Peripheral ECG leads were recorded from 934 female and 946 male dogs from Marshall Farms and 27 females and 30 males from Harlan, either standing on a table or restrained in a hammock. HR, RR, PQ and QT intervals, P and QRS duration and P-wave amplitude were measured. There were no major differences between sexes for ECG parameters. The axis of the heart was shifted to the left when the animals were restrained in a hammock compared to when they were standing on a table. The PQ interval was higher (about 9%) in Harlan than in Marshall dogs. HR was negatively correlated with QT (coefficient of linear correlation: r=-0.61 to -0.74), which emphasizes the need for a formula correcting QT interval for HR when interpreting changes in QT interval. HR was also negatively correlated with PQ intervals (r=-0.26 to -0.11), whereas a positive correlation was found between HR and the amplitude of the P wave (r=0.21-0.34). The level of the respiratory sinus arrhythmia (SA) was quantified by calculating the ratio of maximum to minimum RR interval measured over a 10 s period. This ratio was negatively correlated with HR (r =-0.49 to -0.33). Therefore, at high HRs, SA was less marked than at low HRs, but it did not completely disappear. Analysis of beat-to-beat variation indicated that QT and PQ intervals and the amplitude of P wave fluctuated over time and the degree of this variability was positively correlated with the level of SA. In conclusion, we have established reference values for the duration and/or amplitude of some ECG parameters both in terms of means and variability over the recording period, and we have evaluated the influence of body position, genetic strain and HR on the ECG parameters. These data can be used as baseline for the interpretation of the ECG of Beagle dogs.  相似文献   

4.
The study aimed at defining reference values for electrocardiographic (ECG) and echocardiographic parameters as well as macroscopic dimensions of the heart and microscopic dimensions of cardiomyocytes in the European brown hare. The studies were conducted on 30 adult, clinically healthy hares of either sex caught in Poland. ECG and echocardiography were performed supravitally on anaesthetized hares. After euthanasia, gross and microscopic myocardial and cardiomyocyte dimensions were determined. Heart rate amounted to 140 ± 37.5 beats/min, the leading rhythm involved the sinus rhythm. P wave time was 26 ± 5 ms, PQ time was 80 ms, QRS time was 29 ± 3.5 ms, and ST was 97.5 ± 7 ms. Echocardiography determined a left ventricular wall end-diastolic diameter of 8.6 ± 2.0 mm and an intraventricular septum end-diastolic diameter of 5.75 ± 1.0 mm. The thickness of the interventricular septum corresponded to that of the free wall of the left ventricle, a finding consistent with physiological hypertrophy. Preliminary reference values were established for echocardiography. The findings were similar to those obtained at necropsy. The ECG and echocardiographic studies represent the first supravital examination of cardiac function in the hare. The obtained results illustrate adaptation of hare's myocardium to its mode of life. The cardiac findings resemble the athlete's heart syndrome described in humans. The findings may prove useful in further studies on the physiology of the cardio-vascular system in the hare.  相似文献   

5.
The following haemodynamic values were determined in anaesthetized mongrel dogs: heart rate, systolic blood pressure in the ascending aorta, left ventricular pressure at the peak dp/dt, left ventricular end-diastolic pressure, time interval from Q in ECG to the onset of the systolic wave of dp/dt, time interval from Q in ECG to peak dp/dt, maximum rate of left ventricular pressure rise, femoral arterial flow, and certain indices of left ventricular contractility. It was concluded from the results of these experiments that infusion of a modified gelatin solution Fluigel prevented haemodynamic and metabolic changes produced by experimental hypovolaemia more effectively than infusion of Plasmagel.  相似文献   

6.
除草剂草甘膦异丙胺盐水剂对中华大蟾蜍心电活动的影响   总被引:1,自引:0,他引:1  
采用生物信号采集处理系统对草甘膦异丙胺盐胁迫条件下中华大蟾蜍(BufogargarizansCantor)的心率和心电活动的相关指标进行了测定和分析。不同浓度的草甘膦异丙胺盐溶液被喷施到中华大蟾蜍的体表,由皮肤进入体内而作用于心脏。试验结果表明:随着草甘膦异丙胺盐处理浓度的增大,中华大蟾蜍的心率减慢,心电图中P波、R波和T波的电压峰值降低,而P-R间期、QRS期和Q-T间期的时值延长。草甘膦异丙胺盐胁迫条件下,蟾蜍心率与心电图的各项指标有显著相关性,可用多元线性回归模型分别对蟾蜍心率与心电图中P、R、T波和P-R、QRS、Q-T间期的相关关系进行拟合。多元回归分析结果表明,蟾蜍心电图中Q-T间期值对心率的影响最大,可以推断草甘膦异丙胺盐主要是通过延长蟾蜍心电活动周期中Q-T间期时值即心室收缩期而延长心动周期,导致蟾蜍心率减慢。由此可见草甘膦异丙胺盐水剂的喷施对中华大蟾蜍心脏的电活动周期和机械活动周期均造成了一定影响。  相似文献   

7.
The purpose of this study was to characterize time-frequency behavior using the Continuous Wavelet Transform (CWT) and Fast Fourier Transform (FFT) to analyze ventricular and arterial pressure signals from anesthetized mongrel dogs. Both ventricular and arterial pressure pulsations were recorded using catheter-tip manometers and the CWT was applied to these signals to obtain module coefficients, associated contours, and the 3-D representation of these modules. FFT was applied to obtain the Fourier spectrum. The mathematical analysis of the cardiovascular pressure pulsations permitted the identification of the evolution of the frequency components for the aortic and pulmonary valve functions as well as the intra-ventricular and respiratory influences on the cardiovascular dynamics. The CWT is a very sensitive and reliable procedure for determining the three-dimensional (time-frequency-amplitude) of the oscillatory phenomena during each cardiac cycle, providing more, although complementary, information than the spectral analysis obtained with the FFT. Thanks to the FFT, exact values in Hz could be found for the different events produced in each cycle, and thus the information provided by CWT could be related to the information provided by FFT. The combination of both mathematical methodologies permitted identification of each component of the analyzed signals. The 3D representation allowed an easy comparison of the relative importance of the complex magnitudes in frequency for the different components of the pulsatile waves.  相似文献   

8.
A preliminary study to approach the problem of reliably detecting life threatening ventricular arrhythmias in real time is described. An algorithm (DIAGNOSIS) has been developed in order to classify ECG signal records on the basis of the computation of four simple parameters calculated from a representation in the frequency domain. This algorithm uses a set or rules constituting an operative classification scheme based on the comparison of the parameters with a set of pre-established thresholds. This allows us to differentiate four general categories: ventricular fibrillation-flutter, ventricular rhythms, imitative artefacts and predominant sinus rhythm.  相似文献   

9.
We examined the developmental change by which autonomic neural activity associated respiration modulates spontaneous firing rate of sinus (SA) node and atrioventricular (AV) conduction in premature infants born with low birth weight (LBWI). The purpose of this study was to clarify whether variation of PR is correlated with that of PP or those are independent in LBWI with immature autonomic nervous system. We investigated, therefore, whether there are spontaneous functional differences in the innervation of SA and AV nodes. Further, we evaluated the maturation of autonomic nervous system progressing in the period, on the day of birth (Day 0) to approximately one month after the birth (Month 1). This study was performed in thirteen LBWI during deep sleep. EEG, EOG, ECG, respiratory waves were digitized on line, spontaneous firing cycle of SA node (PP), and AV nodal conduction time (PR) that were recorded on Day 0 and Month 1. Then, the data were analyzed as follows: 1) correlations among the means and standard deviations (SD) of PP, PR and RR, 2) variance evaluation of PP and PR intervals by Lorenz plot analysis method, 3) correlation analysis among PP, PR and RR intervals by linear regression method and 4) frequency analysis for PP and PR intervals by high-speed Fourier transform method (FFT) and determination of frequency density. The PP interval decreased as growing in the period. Contrary PR interval increased. In LBWI, the automatic nervous activities including parasympathetic nerve activity for spontaneous firing cycle of SA node and ventricular excitation cycle on Month 1 were higher than Day 0. It was assumed that the vagal nerve activity for the AV conduction was enhanced. However, there was no significant change in linear regression slope for the spontaneous firing cycle of SA node and the AV conduction time. Postnatal LF/HF changes for PP and PR obtained by frequency analysis, were opposite. Therefore, it was suggested that the maturity of autonomic nervous system progresses in the period, Day 0 to approximately Month 1, but the variations in PP and PR are independent each other.  相似文献   

10.
11.
Both cardiotrophin-1 (CT-1) and B-type or brain natriuretic peptide (BNP) are activated by cardiomyocyte stretch, and gene expression of CT-1 and BNP are augmented in the heart in experimental and human congestive heart failure (CHF). The goal of this study was to define cardiac gene expression of CT-1 and BNP by Northern blot analysis in normal (n=5), early left ventricular dysfunction (ELVD, n=5) and overt CHF dogs (n=5), in which ventricular function is progressively decreased. CT-1 mRNA was detected in both atria and ventricles in normal dogs. Ventricular CT-1 mRNA production increased in ELVD, and it further increased in overt CHF. Ventricular BNP mRNA remained below or at the limit of detection in normal and ELVD models, and it markedly increased in overt CHF. This study reports differential regulation of gene expression of CT-1 and BNP in the heart during the progression of CHF, and demonstrates that ventricular CT-1 gene activation precedes ventricular BNP gene activation.  相似文献   

12.
Bai R  Pu J  Liu N  Lu JG  Zhou Q  Ruan YF  Niu HY  Wang L 《生理学报》2003,55(6):722-730
实验以正常犬和扩张型心肌病心力衰竭犬(dilated cardiomyopathy congestive heart failure,DCM-CHF)模型为对象、以心肌跨室壁复极离散的相关参数为指标,研究左心室心外膜起搏、双心室起搏(模拟临床上心室再同步治疗的方法)后的心肌电生理特性变化。实验以快速右心室起搏的方法制备DCM-CHF犬模型;正常犬和DCM-CHF犬均经射频消融希氏束制备三度房室传导阻滞模型;采用同步记录犬体表心电图和内膜下、中层、外膜下三层心肌单相动作电位(monophasic action potentials,MAP)的方法,测定不同部位起搏时的QT间期、Tpeak-Tend(Tp-Te)间期和三层心肌的单相动作电位时程(MAP duration,MAPD)、跨室壁复极离散度(transmural dispersion of repolaization,TDR)。结果显示:在正常犬,左室心外膜与双心室起搏后三层心肌的MAPD均延长,同时TDR增大(左室心外膜起搏47.16 ms、双心室起搏37.54 ms、右室心内膜起搏26.75 ms,P<0.001),体表心电图Tp-Te间期的变化与之平行;在DCM-CHF犬较正常犬已表现出中层心肌MAPD延长(276.30 ms vs 257.35 ms,P<0.0001)和TDR(33.8 ms vs 27.58 ms,P=0.002)增大的基础上,左室心外膜参与起搏后仍进一步使三层心肌的MAPD延长和TDR增大。研究结果提示,左室心外膜起搏和双心室起搏后使内膜下、中层  相似文献   

13.
目的:探讨心电图左心室劳损(LV)和左心室肥厚(LVH)对无症状主动脉瓣狭窄患者预后的影响。方法:到我院治疗的主动脉瓣狭窄患者766例,心电图左心室劳损和左心室肥厚的预测值用Sokolow-Lyon(SL)电压标准和Cornell电压-时间(CVDP)标准评估,通过对其他预后协变量调整并进行评价。结果:心电图左心室劳损患者的心肌梗死的累计发生率显著高于非心电图劳损的患者(HR=2.7,95%CI:1.4-5.3,P=0.006)。与非心电图左心室肥厚的患者比较,SL标准与CVDP标准联用诊断的左心室肥厚患者心力衰竭的风险显著增加(95%CI:4.7-26.4,P0.001);行主动脉瓣置换术风险显著增加(95%CI:1.6-3.2,P0.001);非致死性梗死、心力衰竭或心血管死亡的复合终点风险也显著增加(95%CI:1.2-3.7,P0.05)。结论:心电图LV和LVH是无症状主动脉瓣狭窄患者预后不良的独立预测因子。  相似文献   

14.
《IRBM》2019,40(3):145-156
ObjectiveElectrocardiogram (ECG) is a diagnostic tool for recording electrical activities of the human heart non-invasively. It is detected by electrodes placed on the surface of the skin in a conductive medium. In medical applications, ECG is used by cardiologists to observe heart anomalies (cardiovascular diseases) such as abnormal heart rhythms, heart attacks, effects of drug dosage on subject's heart and knowledge of previous heart attacks. Recorded ECG signal is generally corrupted by various types of noise/distortion such as cardiac (isoelectric interval, prolonged depolarization and atrial flutter) or extra cardiac (respiration, changes in electrode position, muscle contraction and power line noise). These factors hide the useful information and alter the signal characteristic due to low Signal-to-Noise Ratio (SNR). In such situations, any failure to judge the ECG signal correctly may result in a delay in the treatment and harm a subject (patient) health. Therefore, appropriate pre-processing technique is necessary to improve SNR to facilitate better treatment to the subject. Effects of different pre-processing techniques on ECG signal analysis (based on R-peaks detection) are compared using various Figures of Merit (FoM) such as sensitivity (Se), accuracy (Acc) and detection error rate (DER) along with SNR.MethodsIn this research article, a new fractional wavelet transform (FrWT) has been proposed as a pre-processing technique in order to overcome the disadvantages of other existing commonly used techniques viz. wavelet transform (WT) and the fractional Fourier transform (FrFT). The proposed FrWT technique possesses the properties of multiresolution analysis and represents signal in the fractional domain which consists of representation in terms of rotation of signals in the time–frequency plane. In the literature, ECG signal analysis has been improvised using statistical pre-processing techniques such as principal component analysis (PCA), and independent component analysis (ICA). However, both PCA and ICA are prone to suffer from slight alterations in either signal or noise, unless the basis functions are prepared with a worldwide set of ECG. Independent Principal Component Analysis (IPCA) has been used to overcome this shortcoming of PCA and ICA. Therefore, in this paper three techniques viz. FrFT, FrWT and IPCA are selected for comparison in pre-processing of ECG signals.ResultsThe selected methods have been evaluated on the basis of SNR, Se, Acc and DER of the detected ECG beats. FrWT yields the best results among all the methods considered in this paper; 34.37dB output SNR, 99.98% Se, 99.96% Acc, and 0.036% DER. These results indicate the quality of biology-related information retained from the pre-processed ECG signals for identifying different heart abnormalities.ConclusionCorrect analysis of the acquired ECG signal is the main challenge for cardiologist due to involvement of various types of noises (high and low frequency). Twenty two real time ECG records have been evaluated based on various FoM such as SNR, Se, Acc and DER for the proposed FrWT and existing FrFT and IPCA preprocessing techniques. Acquired real-time ECG database in normal and disease situations is used for the purpose. The values of FoMs indicate high SNR and better detection of R-peaks in a ECG signal which is important for the diagnosis of cardiovascular disease. The proposed FrWT outperforms all other techniques and holds both analytical attributes of the actual ECG signal and alterations in the amplitudes of various ECG waveforms adequately. It also provides signal portrayals in the time-fractional-frequency plane with low computational complexity enabling their use practically for versatile applications.  相似文献   

15.
A large heart rate (HR) increase at the onset of exercise has been linked to an increased risk for adverse cardiovascular events, including cardiac death. However, the relationship between changes in cardiac autonomic regulation induced by exercise onset and the confirmed susceptibility to ventricular fibrillation (VF) has not been established. Therefore, a retrospective analysis of the HR response to exercise onset was made in mongrel dogs with healed myocardial infarctions that were either susceptible (S, n = 131) or resistant (R, n = 114) to VF (induced by a 2-min occlusion of the left circumflex artery during the last minute of exercise). The ECG was recorded, and time series analysis of HR variability (vagal activity index, the 0.24-1.04-Hz frequency component of R-R interval variability) was measured before and 30, 60, and 120 s after the onset of exercise (treadmill running). Exercise elicited significantly (ANOVA, P < 0.0001) greater increases in HR in susceptible dogs at all three times (e.g., at 60 s: R, 46.8 +/- 2.3 vs. S, 57.1 +/- 2.2 beats/min). However, the vagal activity index decreased to a similar extent in both groups of dogs (at 60 s: R, -2.8 +/- 0.1 vs. S, -3.0 +/- 0.2 ln ms2). Beta-adrenoceptor blockade (BB, propranolol 1.0 mg/kg iv) reduced the HR increase and eliminated the differences noted between the groups [at 60 s: R (n = 26), 40.4 +/- 3.2 vs. S (n = 31), 37.5 +/- 2.4 beats/min]. After BB, exercise once again elicited similar declines in vagal activity in both groups (at 60 s: R, -3.6 +/- 0.5 vs. S, -3.2 +/- 0.4 ln ms2). When considered together, these data suggest that at the onset of exercise HR increases to a greater extent in animals prone to VF compared with dogs resistant to this malignant arrhythmia due to an enhanced cardiac sympathetic activation in the susceptible dogs.  相似文献   

16.
The objective of this study was to find out the implication of QRS duration in dogs with rapid pacing-induced heart failure. Sixteen Beagle dogs were implanted with transvenous cardiac pacemakers and underwent rapid right ventricular pacing for 3 weeks at 260 bpm to induce heart failure. Dogs were divided into two groups according to the QRS duration: 9 with normal QRS duration (<100 ms) and 7 with prolonged QRS duration (≥100 ms). Cardiac systolic function and size was analyzed by real time 3-dimensional echocardiography and left ventricular dyssynchrony was assessed by speckle tracking strain imaging. Congestive heart failure developed 3 weeks after rapid right ventricular pacing. Dogs with prolonged QRS duration showed more extensive radial strain and circumferential strain dyssynchrony than dogs with normal QRS duration. At the end of 4-week recovery, greater improvement of left ventricular ejection fraction and left ventricular end-systolic volume was detected in dogs with normal QRS duration. The findings suggested that left ventricular dyssynchrony, indicated by a prolonged QRS duration, predicted an unsatisfying recovery in dogs with rapid pacing-induced heart failure. QRS duration had the potential to be a prognostic indicator for dogs with heart failure.  相似文献   

17.
《IRBM》2014,35(6):351-361
Nowadays, doctors use electrocardiogram (ECG) to diagnose heart diseases commonly. However, some nonideal effects are often distributed in ECG. Discrete wavelet transform (DWT) is efficient for nonstationary signal analysis. In this paper, the Symlets sym5 is chosen as the wavelet function to decompose recorded ECG signals for noise removal. Soft-thresholding method is then applied for feature detection. To detect ECG features, R peak of each heart beat is first detected, and the onset and offset of the QRS complex are then detected. Finally, the signal is reconstructed to remove high frequency interferences and applied with adaptive searching window and threshold to detect P and T waves. We use the MIT-BIH arrhythmia database for algorithm verification. For noise reduction, the SNR improvement is achieved at least 10 dB at SNR 5 dB, and most of the improvement SNR are better than other methods at least 1 dB at different SNR. When applying to the real portable ECG device, all R peaks can be detected when patients walk, run, or move at the speed below 9 km/h. The performance of delineation on database shows in our algorithm can achieve high sensitivity in detecting ECG features. The QRS detector attains a sensitivity over 99.94%, while detectors of P and T waves achieve 99.75% and 99.7%, respectively.  相似文献   

18.
Plateau and pacemaker currents from tissue cultured clusters of embryonic chick heart cells were studied in the time domain, using voltage-clamp steps, and in the frequency domain, using a wide-band noise input superimposed on a steady holding voltage. In the presence of tetrodotoxin to block the sodium channel, a depolarizing voltage step into the plateau range elicited: (a) a rapid (approximately equal to 2 ms) activation of the slow inward current; (b) a subsequent slower (approximately equal to 25 ms) decline in the slow inward current; and (c) activation of a very slow (5 to 10 s) outward current. Impedance studies in this voltage range could clearly resolve two voltage-dependent processes, which appeared to correspond to points b and c above because of their voltage dependence, pharmacology, and time constants. A correlate of point a was also probably present but difficult to resolve owing to the fast time constant of activation for the slow inward channel. At voltages negative to -50 mV a new voltage-dependent process could be resolved, which, because of its voltage dependence and time constant, appeared to represent the pacemaker channel (also termed If or IK2). In the Appendix, linear models of voltage-dependent channels and ion accumulation/depletion are derived and these are compared with our data. Most of the above-mentioned processes could be attributed to voltage-dependent channels with kinetics similar to those observed in time domain, voltage-clamp studies. However, the frequency domain correlate of the decline of the slow inward current was incompatible with channel gating, rather, it appears accumulation/depletion of calcium may dominate the decline in this preparation.  相似文献   

19.
Heart rate recovery after exercise, thought to be related to cardiac parasympathetic tone, has been shown to be a prognostic tool for all-cause mortality. However, the relationship between this variable and confirmed susceptibility to ventricular fibrillation (VF) has not been established. Therefore, myocardial ischemia was induced with a 2-min occlusion of the left circumflex artery during the last minute of exercise in mongrel dogs with myocardial infarction (n = 105 dogs). VF was induced in 66 animals (susceptible), whereas the remaining 39 dogs had no arrhythmias (resistant). On a previous day, ECG was recorded and a time-series analysis of heart rate variability was measured 30, 60, and 120 s after submaximal exercise (treadmill running). The heart rate recovery was significantly greater in resistant dogs than in susceptible dogs at all three times, with the most dramatic difference at the 30-s mark (change from maximum: 48.1 +/- 3.6 beats/min, resistant dogs; 31.0 +/- 2.2 beats/min, susceptible dogs). Correspondingly, indexes of parasympathetic tone increased to a significantly greater extent in resistant dogs at 30 and 60 s after exercise. These differences were eliminated by atropine pretreatment. When considered together, these data suggest that resistant animals exhibit a more rapid recovery of vagal activity after exercise than those susceptible to VF. As such, postexercise heart rate recovery may help identify patients with a high risk for VF following myocardial infarction.  相似文献   

20.
Sodium channels have four homologous domains (D1-D4) each with six putative transmembrane segments (S1-S6). The highly charged S4 segments in each domain are postulated voltage sensors for gating. We made 15 charge-neutralizing or -reversing substitutions in the first or third basic residues (arginine or lysine) by replacement with histidine, glutamine, or glutamate in S4 segments of each domain of the human heart Na+ channel. Nine of the mutations cause shifts in the conductance-voltage (G-V) midpoints, and all but two significantly decrease the voltage dependence of peak Na+ current, consistent with a role of S4 segments in activation. The decreases in voltage dependence of activation were equivalent to a decrease in apparent gating charge of 0.5-2.1 elementary charges (eo) per channel for single charge- neutralizing mutations. Three charge-reversing mutations gave decreases of 1.2-1.9 eo per channel in voltage dependence of activation. The steady-state inactivation (h infinity) curves were fit by single- component Boltzmann functions and show significant decreases in slope for 9 of the 15 mutants and shifts of midpoints in 9 mutants. The voltage dependence of inactivation time constants is markedly decreased by mutations only in S4D4, providing further evidence that this segment plays a unique role in activation-inactivation coupling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号