首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 209 毫秒
1.
System for DNA sequencing with resolution of up to 600 base pairs   总被引:16,自引:0,他引:16  
A system capable of resolving about 500 bases is of interest for sequencing of longer DNA molecules. Studies on further optimization of resolution on DNA sequencing gels were carried out. The effect of physico-chemical properties of gels and buffers on resolution were tested, e.g. ionic strength and pH of buffers, different buffer systems, acrylamide concentration, crosslinker concentration, type of crosslinker, temperature of polymerization, denaturing conditions, gel length and thickness. Tested were as well different running conditions like electric field, gel temperature, dimension of sample slots. Gels 0.1-0.2 mm thick and up to 1.2 m long were cast and tested routinely. Gel lengths of 60-70 cm (for sequencing up to 350-400 bases) to about 100 cm (above 400 bases) are practicable. Little is gained in resolution by increasing the gel length from 1 to 1.2 m. Resolution was improved using 0.1 mm thick gels, at a higher pH value of 8.6-8.8, and molarity increased to 0.2 M. The sequencing pattern in the region of higher bases could be better resolved on a twice-magnified picture of that region on the autoradiogram. With the long gels (70-120 cm), it is advantageous to obtain the sequence overlap by running in parallel gels of different concentrations, without re-application of samples, all loaded at the same time. Buffer chamber for running of two of three gels and thermostating plates up to 1.2 m long were designed. In this way four to six thermostated gels can be run from a power supply with two inputs. Three 1 m long gels (concentrations: 4%, 6%, 12-16%) are loaded with several samples of DNA to be sequenced and run in parallel without re-application of the samples. With good samples, the sequence overlap from the gels could be counted up to 500 base pairs, with exceptionally good samples closer to 600 bases. At present this number seems to be near the limit of the resolving power of the polyacrylamide gels.  相似文献   

2.
We have developed a simple and efficient technique for automated parallel loading of >/=200 lanes on a 30 cm-wide gel in automated DNA sequencing, using porous filter materials and an associated manual or robotic system. The samples are loaded onto the teeth of a comb made of the porous material. The comb, with samples, is inserted directly above the straight edge of the polymerized gel. The samples are driven from the comb into the gel by the applied electrical field. A particularly advantageous aspect of this method is the elimination of the thin gel walls separating the sample wells in the standard gel loading technique. The time for sample loading is significantly reduced to a few minutes. The loading technique is applicable to horizontal or vertical systems, with standard or ultrathin gels.  相似文献   

3.
A simple system has been designed enabling ultrasensitive on-line detection of fluorescently labelled macromolecules, e.g. nucleic acids, proteins and peptides during electrophoretic separations in gels. An important application is the automated DNA sequence determination without radioactivity. Drying of gels, film exposure and handling are not necessary. A sulphydryl containing M13 sequencing primer has been synthesised and end-labelled in a reaction with fluorescein iodoacetamide. This is then used in the dideoxy reactions. In particular no moving parts or complicated software are required for data collection and analysis. Compared to our first automated device detection sensitivity has been improved by a factor of thirty to about 3 X 10(-18) mol per band. The resolution has increased to about 400 bases in 5 hours, with the possibility to read up to about 500 bases when they are properly labelled. Gels shorter than 20 cm may be used for resolution of about 300 bases. The single gel system may be upgraded for simultaneous running and reading of six or ten sequencing samples.  相似文献   

4.
A high-sensitivity, laser-excited confocal fluorescence gel scanner has been developed and applied to the detection of fluorescently labeled DNA. An argon ion laser (1-10 mW at 488 nm) is focused in the gel with a high-numerical aperture microscope objective. The laser-excited fluorescence is gathered by the objective and focused on a confocal spatial filter, followed by a spectral filter and photodetector. The gel is placed on a computer-controlled scan stage, and the scanned image of the gel fluorescence is stored and analyzed in a computer. This scanner has been used to detect DNA separated on sequencing gels, agarose mapping gels and pulsed field gels. Sanger sequencing gels were run on M13mp18 DNA using a fluoresceinated primer. The 400-microns-thick gels, loaded with 30 fmol of DNA fragments in 3-mm lanes, were scanned at 78-microns resolution. The high resolution of our scanner coupled with image processing allows us to read up to approximately 300 bases in four adjacent sequencing lanes. The minimum band size that could be detected and read was approximately 200 microns. This instrument has a limiting detection sensitivity of approximately 10 amol of fluorescein-labeled DNA in a 1 x 3-mm band. In applications to agarose mapping gels, we have exploited the fact that DNA can be prestained with ethidium homodimer, followed by electrophoresis and fluorescence detection to achieve picogram sensitivity. We have also developed methods using both ethidium homodimer and thiazole orange staining which permit two-color detection of DNA in one lane.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
DNA sequencing separations of standard DNA fragments of known sequence have been achieved in small diameter capillary gels electrophoresed and analyzed in parallel in a modified commercial DNA sequencer instrument. DNA sequencing in terms of base-calling accuracy is comparable to conventional slab gels; however, the separations in the capillary were performed somewhat faster and required less sample than those in the slab gel. Advantages of this approach vs. separations on conventional slab gels are discussed.  相似文献   

6.
Introduction The completion of the Human Genome Project has triggered large-scale screening of genomes (1) and proteomes (2) in aims to find out candidate genes related to diseases (3), perform expression analyses at the mRNA level (4) or at the protein level (5), discover new drugs (6), and analyze molecular in- teractions (7). For such purposes, technologies han- dling a tiny amount of samples should be developed, of which the importance has already been described as the ambient analyte th…  相似文献   

7.
A non-radioactive automated method for DNA sequence determination   总被引:27,自引:0,他引:27  
A method and instrument for automated DNA sequencing without radioactivity have been developed. In spite of the success with radioactive labels there are drawbacks attached to the technique, such as hazards in the handling, storage and disposal of radioactive materials, and the considerable cost of the radiolabelled nucleoside triphosphates. In addition, there is deterioration of sample quality with time. A sulphydryl containing M13 sequencing primer has been synthesised and subsequently conjugated with tetramethylrhodamine iodoacetamide. The fluorescent primer is used to generate a nested set of fluorescent DNA fragments. The fluorescent bands are excited by a laser and detected in the gel (detection limit about 0.1 fmol per band) during electrophoresis, and sequence data from the four tracks are transferred directly into a computer. Standard gels, 200 mm wide with 20 sample slots have also been used. The device contains no moving parts. At present 250-300 bases can be read in 6 h. The system is capable of single base resolution at a fragment length of at least 400 bases.  相似文献   

8.
A technique has been developed for high lane density loading of small-volume DNA samples in a horizontal agarose gel. This technique has been investigated with a simple hand-held tool that is made to couple to sample output from a new capillary-based sample automation system. The approach consists of piercing the gel with pressurized sample capillaries and relieving the pressure shortly before withdrawal. The pressurization prevents the capillary from aspirating the gel buffer and keeps the sample at the tip of the capillary, so that it may be sucked into the gel during withdrawal. This method is shown to be adequate for a wide range of DNA ladders and PCR-based screening. In addition to allowing smaller lanes and a higher lane density than is achievable with traditional well-forming techniques, it relaxes the need for well formation and the alignment of the sample loader with those wells, providing an easy, efficient means of loading agarose gels.  相似文献   

9.
MeltMADGE reconfigures the mutation scanning process of denaturing gradient gel electrophoresis so that the independent variable is time rather than space and the dependent (denaturing) variable is temperature rather than concentration of chemical denaturant. Use of a thermal ramp enables the use of a homogeneous gel and therefore of high-density arrays of wells such as those of microplate array diagonal gel electrophoresis (MADGE). In this configuration, electrophoresis of products on 10-12 96-well meltMADGE gels can be conducted in a 1- to 2-liter tank in a 1- to 2-h run, enabling the scanning of a target amplicon in over 1,000 subjects simultaneously. Gels are read by imaging the fluorescence of UV-excited ethidium bromide, giving a simple, economical system for identifying rarer sequence variants in target genes; it is suitable for large-scale case-control or population studies and other comparable applications. Different amplicons with similar melting characteristics can also be combined in the same run.  相似文献   

10.
O'Dell SD  Gaunt TR  Day IN 《BioTechniques》2000,29(3):500-4, 505-6
A new modification of the microplate array diagonal gel electrophoresis (MADGE) system accommodates the dual amplification refractory mutation system (ARMS) products of 96 samples on one 192-well gel. Simultaneous electrophoresis of a number of horizontal ARMS-MADGE gels achieves high throughput. Gels are imaged digitally, here using the FluorImager 595 fluorescent scanning system. Customized software by Phoretix enables rapid computerized calling of band patterns in ARMS-MADGE arrays, in which the two wells receiving a pair of allele-specific assays for a single template are juxtaposed to form one virtual track, with genotype data exported directly into Microsoft Excel for statistical analysis. An ARMS assay of the A/T base change at the -23/HphI RFLP in the insulin gene promoter, which initiates from 2.5 ng template DNA, was used here to demonstrate this improved general approach for population SNP analyses.  相似文献   

11.
We report a safe, rapid, and economical method for polymerase chain reaction (PCR)-based genotype analysis using a microsatellite marker specific for the human chromosome 18 locus, D18S53. This method does not involve radioisotopes and makes use of ethidium bromide fluorescence to detect PCR products. Our method enables direct analysis and easy detection of PCR products on nondenaturing polyacrylamide gels. The genotyping using this method can be scaled up to 100 samples at one time by adding a step of “double loading” of samples in a single sequencing size gel. We could resolve PCR products and DNA fragments, differing in size by only 2 bp, in the range of 150–200 bp by a 7% nondenaturing polyacrylamide gel. This technique can be applied for population-based genomic screening and linkage analysis.  相似文献   

12.
We describe herein a modified differential gene display (DGD) technique that can be rapidly and simply performed and that eliminates the need for radioactivity by fluorescent visualization of complementary deoxyribonucleic acid (cDNA) bands with SYBR gold nucleic acid gel stain. To streamline the DGD procedure, a number of modifications were employed. Ribonucleic acid isolated from differentially treated populations of human trabecular bone-derived mesenchymal progenitor cells was reverse-transcribed into cDNA using oligo-dT primer, and subsequent amplification of differentially expressed cDNAs was done using arbitrary 25-mer primers and oligo-dT9 30-mer primers. Moderate-sized nondenaturing 6% polyacrylamide gels (30 × 20 cm) of 1.5-mm thickness were used for easier handling and increased sample loading capacity. Gels were subjected to electrophoresis overnight, stained with SYBR gold, and visualized and photographed using a commercially available gel imager. DNA bands ranging in size from 100 to 400 bp were visualized directly on an ultraviolet transilluminator, excised from the gel, and reamplified. The cDNA amplicons were subcloned, sequenced, and gene sequences were identified by a Basic Local Alignment Search Tool of genomic databases. Overall, this rapid and functional method proved quite effective for identification of novel genes that may be of interest in studies of cartilage and bone differentiation.  相似文献   

13.
Multiwavelength detection of laser induced fluorescence for dideoxynucleotide DNA sequencing with four different fluorophores and separation by capillary gel electrophoresis is described. A cryogenically cooled, low readout noise, 2-dimensional charge-coupled device is used as a detector for the on-line, on-column recording of emission spectra. The detection system has no moving parts and provides wavelength selectivity on a single detector device. The detection limit of fluorescently labeled oligonucleotides meets the high sensitivity requirements for capillary DNA sequencing largely due to the efficient operation of the CCD detector with a 94% duty cycle. Using the condition number as a selectivity criterion, multiwavelength detection provides better analytical selectivity than detection with four bandpass filters. Monte Carlo studies and analytical estimates show that base assignment errors are reduced with peak identification based on entire emission spectra. High-speed separation of sequencing samples and the treatment of the 2-dimensional electropherogram data is presented. Comparing the DNA sequence of a sample separated by slab gel electrophoresis with sequence from capillary gel electrophoresis and multiwavelength detection we find no significant difference in the amount of error attributable to the instrumentation.  相似文献   

14.
Urea PAGE or denaturing urea polyacrylamide gel electrophoresis employs 6-8 M urea, which denatures secondary DNA or RNA structures and is used for their separation in a polyacrylamide gel matrix based on the molecular weight. Fragments between 2 to 500 bases, with length differences as small as a single nucleotide, can be separated using this method1. The migration of the sample is dependent on the chosen acrylamide concentration. A higher percentage of polyacrylamide resolves lower molecular weight fragments. The combination of urea and temperatures of 45-55 °C during the gel run allows for the separation of unstructured DNA or RNA molecules.In general this method is required to analyze or purify single stranded DNA or RNA fragments, such as synthesized or labeled oligonucleotides or products from enzymatic cleavage reactions.In this video article we show how to prepare and run the denaturing urea polyacrylamide gels. Technical tips are included, in addition to the original protocol 1,2.  相似文献   

15.
从琼脂糖凝胶中高效回收DNA技术的探讨   总被引:1,自引:0,他引:1  
用两只离心管制成的凝胶过滤装置,从电泳后的琼脂糖凝胶中回收DNA片段的简易方法。它依次包括以下步骤:凝胶过滤装置的制作、凝胶切割、凝胶低温冷冻、低温高速离心、ddH20洗胶、DNA纯化和回收效果检测等。用此方法回收的DNA片段产率高、质量纯,可直接用于分子生物学实验的后续操作,如载体连接、PCR模板获得、DNA探针制备、基因测序等。其优点是:DNA片段的回收率高(90%以上),质量好;操作简便,耗时短;回收装置简单,成本低廉,可进行商品化开发。  相似文献   

16.
Scott GB  Steffen DL  Edgar D  Warren JT  Kovár CL  Scherer SE  Havlak PH  Gibbs RA 《BioTechniques》2002,32(6):1366, 1368, 1370-1366, 1368, 1371
Here we describe the development of a novel software tool entitled Loader Lite that generates plate records or sample sheetsfor the ABI PRISMs 3700 DNA sequencer. The major advantage of this program is that it enables the ongoing operation of sequencing instruments without reference to external network(s). The autonomous operation of sequencing instruments is critical if sample throughput is to be maintained during periods of network outage. Loader Lite employs a deliberate strategy of inputting anonymous tray barcodes at run time. After sequencing, the barcodes are reconciled with relevant project details by reference to a database. This software takes advantage of barcode scanning technology by creating plate records directly on the local computer, serving an individual sequencer, immediately before importing and linking. This real-time synthesis of the plate records at the point of loading all but eliminates loading errors. Loader Lite is user-friendly, fully configurable, and permits the running of partial or full 384-well sample trays, using any standard combinations of run modules, dye sets, mobility files, analysis modules, etc. The 96-well format is not supported; however, this capability will appear in subsequent versions that are currently under development. This application is designed as an added value, adjunct program to the regular ABI PRISM 3700 Data Collection software. We have successfully used Loader Lite over the past six months to load approximately 7 million sequencing reactions and believe its utility and functionality will prove to be attractive to the wider sequencing community.  相似文献   

17.
The ABI Sequencing Analysis application is designed specifically for the analysis of data produced by the ABI DNA Sequencer. The ABI sequencer is a laser-based instrument that utilizes fluorescent labels to analyze the products of a sequencing reaction as they migrate through a gel. After the data are collected from a sequencing run, the Analysis program identifies and tracks the sample lanes of the gel and subsequently normalizes and integrates the raw data into a chromatogram of the final sequence. For the use, there are basically two types of files that can be manipulated to potentially improve the analysis results. The Gel File consists of a computer generated image of the sequencing gel with the fluorescent DNA banding patterns. This image allows the user to view and edit the tracking lines generated and used by Analysis to collect data points for each sample. Individual Sample Files are stored for each of the samples analyzed and include the chromatogram, raw data, and annotations and information regarding the sample and sequence run. Generally, the products of a sequencing reaction are easily resolved and the Analysis software interprets the correct nucleotide sequence. Ambiguous base calls tend to occur near the end of the sequence and may be either edited or deleted by the user before exporting the data for further comparisons or alignments. Occasionally the tracking lines within the gel image may need to be adjusted or moved. The sample data are then reextracted from the Gel File and analyzed again. This review explains the general operation of Analysis in terms of viewing and editing a chromatogram, retracking the lanes of a Gel File, and analyzing the final sample data. The three versions 1.2.1, 2.1.2, and 3.3 are discussed.  相似文献   

18.
Electrophoresis on slab gels containing a linear gradient of polyacrylamide concentration has been used to separate DNA fragments obtained by restriction of viral DNAs. A simple method of preparing gradient gels using a sucrose density-gradient mixer and preexisting slab gel apparatus is described. DNA fragments of molecular weights 7 × 104–14 × 106 have been fractionated on gels of 3.5–7.5% and 2.5–7.5% acrylamide concentration. In addition to the wide range of fragment sizes which may be run on a single gel, a further advantage of the system is that much sharper bands are obtained compared to conventional constant concentration gels, thus improving resolution.In the molecular-weight range below 5 × 106, for bands whose terminal velocities in the polyacrylamide concentration gradient approach zero, an approximately linear relationship holds between the logarithms of the molecular weights of the fragments and the logarithms of the distances they have migrated in the gel. Thus, by choosing a suitable upper limit to the concentration gradient, the gel system provides a method for estimating approximate molecular weights of unknown DNA fragments, by comparing their mobilities to known standards.  相似文献   

19.
The comparison of two-dimensional (2-D) gel images from different samples is an established method used to study differences in protein expression. Conventional methods rely on comparing images from at least 2 different gels. Due to the high variation between gels, detection and quantification of protein differences can be problematic. Two-dimensional difference gel electrophoresis (Ettan trade mark DIGE) is an emerging technique for comparative proteomics, which improves the reproducibility and reliability of differential protein expression analysis between samples. In the application of DIGE different samples are labelled with mass and charge matched spectrally resolvable fluorescent dyes and are then separated on the same 2-D gel. Using an Escherichia coli lysate "spiked" with varying amounts of four different known proteins, we have tested a novel experimental design that exploits the sample multiplexing capabilities of DIGE, by including a standard sample in each gel. The standard sample comprises equal amounts of each sample to be compared and was found to improve the accuracy of protein quantification between samples from different gels allowing accurate detection of small differences in protein levels between samples.  相似文献   

20.
A method is described whereby a large number of chromatographic fractions containing protein or enzyme components may be run on a single-starch gel. A multiple punch for making the sample holes, gel slab support, and a gel slicer used to cut several slices from the one gel for staining for the various enzyme or protien constituents are described. An example is given of a run using fractions obtained from a Sephadex G-200 column chromatography run of a herring muscle extract. Densitometry may be used to assay the stained gels. In another example a commercially obtained muscle lactate dehydrogenase preparation was chromatographed on a Sephadex G-200 column. The electrophoretic run of the fractions revealed the presence of both heart-type A and muscle-type B lactate dehydrogenase subunits and showed that the column run had effected a partial separation of the various tetramers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号