共查询到20条相似文献,搜索用时 31 毫秒
1.
Roger Cai Xiang Soh Guan Heng Tay Wen Siang Lew James Cheow Lei Lee 《Reports of Practical Oncology and Radiotherapy》2018,23(5):413-424
Aim
To identifying depth dose differences between the two versions of the algorithms using AIP CT of a 4D dataset.Background
Motion due to respiration may challenge dose prediction of dose calculation algorithms during treatment planning.Materials and methods
The two versions of depth dose calculation algorithms, namely, Anisotropic Analytical Algorithm (AAA) version 10.0 (AAAv10.0), AAA version 13.6 (AAAv13.6) and Acuros XB dose calculation (AXB) algorithm version 10.0 (AXBv10.0), AXB version 13.6 (AXBv13.6), were compared against a full MC simulated 6X photon beam using QUASAR respiratory motion phantom with a moving chest wall. To simulate the moving chest wall, a 4 cm thick wax mould was attached to the lung insert of the phantom. Depth doses along the central axis were compared in the anterior and lateral beam direction for field sizes 2 × 2 cm2, 4 × 4 cm2 and 10 × 10 cm2.Results
For the lateral beam direction, the moving chest wall highlighted differences of up to 105% for AAAv10.0 and 40% for AXBv10.0 from MC calculations in the surface and buildup doses. AAAv13.6 and AXBv13.6 agrees with MC predictions to within 10% at similar depth. For anterior beam doses, dose differences predicted for both versions of AAA and AXB algorithm were within 7% and results were consistent with static heterogeneous studies.Conclusions
The presence of the moving chest wall was capable of identifying depth dose differences between the two versions of the algorithms. These differences could not be identified in the static chest wall as shown in the anterior beam depth dose calculations. 相似文献2.
Elham Hosseinzadeh Nooshin Banaee Hassan Ali Nedaie 《Reports of Practical Oncology and Radiotherapy》2018,23(1):39-46
Aim
The aim of this study is to calculate neutron contamination at the presence of circular cones irradiating by 18 MV photons using Monte Carlo code.Background
Small photon fields are one of the most useful methods in radiotherapy. One of the techniques for shaping small photon beams is applying circular cones made of lead. Using this method in high energy photon due to neutron contamination is a crucial issue.Materials and methods
Initially, Varian linac producing 18 MV photons was simulated and after validating the code, various circular cones were also simulated. Then, the number of neutrons, neutron equivalent dose and absorbed dose per Gy of photon dose were calculated along the central axis.Results
Number of neutrons per Gy of photon dose had their maximum value at depth of 2 cm and these values for 5, 10, 15, 20 and 30 mm circular cones were 9.02, 7.76, 7.61, 6.02 and 5.08 (n cm?2 Gy?1), respectively. Neutron equivalent doses per Gy of photon dose had their maximum at the surface of the phantom and these values for mentioned collimators were 1.48, 1.33, 1.31, 1.12 and 1.08 (mSv Gy?1), respectively. Neutron absorbed doses had their maximum at the surface of the phantom and these values for mentioned collimators sizes were 103.74, 99.71, 95.77, 81.46 and 78.20 (μGy/Gy), respectively.Conclusions
As the field size gets smaller, number of neutrons, equivalent and absorbed dose per Gy of photon increase. Also, neutron equivalent dose and absorbed dose are maximum at the surface of phantom and then these values will be decreased. 相似文献3.
Aim
In this study, at different fields, energies and gantry angles, treatment couch and rails dose absorption ratio and treatment couch effect on surface and build-up region doses were examined.Background
It is assumed that radiation attenuation is minimal because the carbon fiber couches have low density and it is not generally accounted for during treatment planning. Consequently, it leads to a major dosimetric mistake.Materials and methods
Solid water phantom was used for relative dose measurement. The measurements were done using a Farmer ion chamber with 0.6 cc volume and a parallel plane ion chamber starting from surface with 1 mm depth intervals at 10 × 10 cm2 field, SSD 100 cm. Measurements were taken for situations where the beams intersect the couch and couch rails.Results
Dose absorption ratio of carbon fiber couch obtained at gantry angle of 180° was 1.52%, 0.69%, 0.33% and 0.25% at different field sizes for 6 MV. For 15 MV, this ratio was 0.95%, 0.27%, 0.20% and 0.05%. The absorption ratio is between 3.4% and 1.22% when the beams intersect with couch rails. The couch effect increased surface dose from 14% to 70% for 6 MV and from 11.34% to 53.03% for 15 MV.Conclusions
The results showed that the carbon fiber couch increased surface dose during posterior irradiation. Therefore, the skin-sparing effect of the high energy beams was decreased. If the effect of couch is not considered, it may cause significant differences at dose which reaches the patient and may cause tissue problems such as erythema. 相似文献4.
Hediye Acun-Bucht Ebru Tuncay Emin Darendeliler Gönül Kemikler 《Reports of Practical Oncology and Radiotherapy》2018,23(4):242-250
Aim
This study aims at examining absolute dose verification of step-and-shoot intensity modulated radiation treatment (IMRT) of prostate and brain patients by use of ion chambers of two different volumes and thermoluminescent detectors (TLD).Background
The volume of the ion chamber (IC) is very important for absolute dose verification of IMRT plans since the IC has a volume average effect. With TLD detectors absolute dose verification can be done measuring the dose of multiple points simultaneously.Materials and methods
Ion chambers FC65-P of volume 0.65 cc and semiflex of volume 0.125 cc as well as TLDs were used to measure the central axis absolute dose of IMRT quality assurance (QA) plans. The results were compared with doses calculated by a treatment planning system (TPS). The absolute doses of off axis points located 2 cm and 4 cm away from the isocenter were measured with TLDs.Results
The measurements of the 0.125 cc ion chamber were found to be closer to TPS calculations compared to the 0.65 cc ion chamber, for both patient groups. For both groups the root mean square (RMS) differences between doses of the TPS and the TLD detectors are within 3.0% for the central axis and points 2 cm away from the isocenter of each axis. Larger deviations were found at the field edges, which have steep dose gradient.Conclusions
The 0.125 cc ion chamber measures the absolute dose of the isocenter more accurately compared to the 0.65 cc chamber. TLDs have good accuracy (within 3.0%) for absolute dose measurements of in-field points. 相似文献5.
Claudio Farías-Valenzuela Cristian Pérez-Luco Rodrigo Ramírez-Campillo Cristian Álvarez Mauricio Castro-Sepúlveda 《Revista espa?ola de geriatría y gerontología》2018,53(3):141-144
Background
Handgrip strength (HS) and peak oxygen consumption (Vo2peak) are powerful predictors of cardiovascular risk, although it is unknown which of the two variables is the better predictor.Aim
The objective of the following study was to relate HS and Vo2peak to cardiovascular risk markers in older Chilean women.Methods
Physically active adult women (n = 51; age, 69 ± 4.7 years) participated in this study. The HS and Vo2peak were evaluated and related to the anthropometric variables of body mass, body mass index (BMI), waist circumference (WC), hip circumference (HC), waist ratio (WR), and waist height ratio (WHR), as well as with the cardiovascular variables systolic (SBP) and diastolic (DBP) and cardiac recovery in one minute (RHR1). A multilinear regression model was used for the analysis of the associated variables (P < .05).Results
The cardiovascular risk markers associated (P < .05) with the handgrip strength of the dominant limb (HSDL) were body mass, BMI, WR, and WHR. The handgrip strength of the non-dominant limb (HSNDL) was associated with body mass. Vo2peak was associated with body mass, BMI, HC and RHR1. The multilinear regression model showed a value of r = 0.43 in HSDL, r = 0.39 in HSNDL and r = 0.69 in peak Vo2.Conclusion
Although HS and Vo2peak were related to cardiovascular risk markers, Vo2peak offers greater associative power with these cardiovascular risk factors. 相似文献6.
Daisuke Kawahara Shuichi Ozawa Takeo Nakashima Shintaro Tsuda Yusuke Ochi Takuro Okumura Hirokazu Masuda Kazunari Hioki Tathsuhiko Suzuki Yoshimi Ohno Tomoki Kimura Yuji Murakami Yasushi Nagata 《Reports of Practical Oncology and Radiotherapy》2018,23(2):84-90
Aim and background
IGRT based on bone matching may produce a large target positioning error in terms of the reproducibility of expiration breath-holding on SBRT for liver cancer. We evaluated the intrafractional and interfractional errors using the diaphragm position at the end of expiration by utilising Abches and analysed the factor of the interfractional error.Materials and methods
Intrafractional and interfractional errors were measured using a couple of frontal kV images, planning computed tomography (pCT) and daily cone-beam computed tomography (CBCT). Moreover, max–min diaphragm position within daily CBCT image sets with respect to pCT and the maximum value of diaphragm position difference between CBCT and pCT were calculated.Results
The mean ± SD (standard deviation) of the intra-fraction diaphragm position variation in the frontal kV images was 1.0 ± 0.7 mm in the C-C direction. The inter-fractional diaphragm changes were 0.4 ± 4.6 mm in the C-C direction, 1.4 ± 2.2 mm in the A-P direction, and ?0.6 ± 1.8 mm in the L-R direction. There were no significant differences between the maximum value of the max–min diaphragm position within daily CBCT image sets with respect to pCT and the maximum value of diaphragm position difference between CBCT and pCT.Conclusions
Residual intrafractional variability of diaphragm position is minimal, but large interfractional diaphragm changes were observed. There was a small effect in the patient condition difference between pCT and CBCT. The impact of the difference in daily breath-holds on the interfractional diaphragm position was large or the difference in daily breath-holding heavily influenced the interfractional diaphragm change. 相似文献7.
Avinash H. Udayashankar Shibina Noorjahan Nirmala Srikantia K. Ravindra Babu Sandeep Muzumder 《Reports of Practical Oncology and Radiotherapy》2018,23(4):233-241
Aim
To identify the most reproducible technique of patient positioning and immobilization during pelvic radiotherapy.Background
Radiotherapy plays an important role in the treatment of pelvic malignancies. Errors in positioning of patient are an integral component of treatment. The present study compares two methods of immobilization with no immobilization with an aim of identifying the most reproducible method.Materials and methods
65 consecutive patients receiving pelvic external beam radiotherapy were retrospectively analyzed. 30, 21 and 14 patients were treated with no-immobilization with a leg separator, whole body vacuum bag cushion (VBC) and six point aquaplast immobilization system, respectively. The systematic error, random error and the planning target volume (PTV) margins were calculated for all the three techniques and statistically analyzed.Results
The systematic errors were the highest in the VBC and random errors were the highest in the aquaplast group. Both systematic and random errors were the lowest in patients treated with no-immobilization. 3D Systematic error (mm, mean ± 1SD) was 4.31 ± 3.84, 3.39 ± 1.71 and 2.42 ± 0.97 for VBC, aquaplast and no-immobilization, respectively. 3D random error (mm, 1SD) was 2.96, 3.59 and 1.39 for VBC, aquaplast and no-immobilization, respectively. The differences were statistically significant between all the three groups. The calculated PTV margins were the smallest for the no-immobilization technique with 4.56, 4.69 and 4.59 mm, respectively, in x, y and z axes, respectively.Conclusions
Among the three techniques, no-immobilization technique with leg separator was the most reproducible technique with the smallest PTV margins. For obvious reasons, this technique is the least time consuming and most economically viable in developing countries. 相似文献8.
9.
Cristina Buiza Javier Yanguas Amaia Zulaica Iván Antón Enrique Arriola Alvaro García 《Revista espa?ola de geriatría y gerontología》2018,53(4):208-212
Introduction
Adaptation and validation to the Basque language of tests to assess advanced cognitive impairment is a not covered need for Basque-speaking people. The present work shows the validation of the Basque version of the Severe Mini Mental State Examination (SMMSE).Material and methods
A total of 109 people with advanced dementia (MEC < 15) took part in the validation study, and were classified as GDS 5-7 on the Geriatric Depression Scale (GDS). All participants were Spanish-Basque bilingual.Results
It was shown that SMMSE-eus has a high internal consistency (alpha = 0.92), a good test-retest reliability (r = 0.88; P < .01), and a high inter-rater reliability (CCI = 0.99; P < .00) for the overall score, as well as for each item.Conclusions
Both the high internal consistency and inter-rater reliability, and to a lesser extent, test-retest reliability, made the SMMSE-eus a valid test for the brief assessment of cognitive status in people with advanced dementia in Basque-speaking people. For this reason, the SMMSE-eus is a usable and reliable alternative for assessing Basque-speaking people in their mother-tongue, or preferred language. 相似文献10.
Sandeep Kumar Vishwakarma Avinash Bardia L. Chandrakala Sana Arshiya Syed Ameer Basha Paspala Vishnupriya Satti Aleem Ahmed Khan 《Tissue & cell》2017,49(6):638-647
Introduction
Progress in understanding pathophysiological mechanisms and the development of targeted regenerative strategies have been hampered by the lack of predictive disease models, specifically for the conditions to which affected cell types are inaccessible. The present study has aimed to unearth the role of valproic acid (VPA) and mild hypothermia (MH) as promising strategy to enhance the neuroprotective mechanisms in undifferentiated and differentiated human neural precursor cells (hNPCs) against ethanol-induced damage.Methods
5 mM VPA alone or in combination with MH (33 °C) was used to prevent the damage in proliferating and differentiating hNPCs. CD133 + ve enriched hNPCs were cultured in vitro and exposed to 1 M chronic ethanol concentration for 72 h and followed by VPA and MH treatment for 24 h. Morphometric analysis was performed to identify changes in neurospheres development and neuronal cell phenotypes. Flow cytometry and RT-qPCR analysis was performed to investigate alterations in key molecular pathways involved in cell survival and signaling.Results
Combination of VPA with MH displayed higher proportion of neuronal cell viability as compared to single treatment. Combination treatment was most effective in reducing apoptosis and reactive oxygen species levels in both the undifferentiated and differentiated hNPCs. VPA with MH significantly improved neuronal cell phenotype, active chromatin modeling, chaperon and multi-drug resistant pumps activity and expression of neuronal signaling molecules.Conclusion
The study provided an efficient and disease specific in vitro model and demonstrated that combined treatment with VPA and MH activates several neuroprotective mechanisms and provides enhanced protection against ethanol-induced damage in cultured undifferentiated and differentiated hNPCs. 相似文献11.
Oriol Turró Garriga Sílvia Farrés Costa Albert Pérez Terré Pau Batlle Amat 《Revista espa?ola de geriatría y gerontología》2018,53(4):196-201
Introduction
The care of dependent persons is arduous, and requires time, energy, and physical effort on the part of caregivers. Personal characteristics, such as the sense of coherence (SOC), can influence the perceived burden and care giving.Objective
To determine the impact of SOC on the perceived burden and to determine if these characteristics are associated with adherence to a psycho-educational program for informal caregivers.Material and method
Prospective observational study of caregivers of dependent persons participating in the ‘School of Caregivers’, a psycho-educational program for family and paid caregivers. An analysis was made of the SOC-13 items and the results of the Zarit Burden Interview. The relationship between the SOC and the adherence to the program (≥ 50% sessions) was also analysed.Results
The study included 96 participants, with 71.9% family carers. The higher burden was associated with a lower SOC meaningfulness factor (β = –0.388; P = .002), and to be a relative vs. paid carer (β = –0.300; P = .010). Just over half (52.1%) of carers completed 50% or more sessions, and in the case of the relatives, this adherence increased by higher SOC (OR: 1.1, P = .034), and lower burden (OR: 0.95, P = .032). The lack of adherence of paid caregivers was not associated with any of the analysed variables.Conclusions
The sense of coherence and mainly the meaning, is a characteristic to take into account for the adaptation of interventions in caregivers and provide them with greater equity working more on the people who need it the most (lower SOC and greater burden). 相似文献12.
Naoki Kinoshita Hiroshi Oguchi Toshiki Adachi Hiroki Shioura Hirohiko Kimura 《Reports of Practical Oncology and Radiotherapy》2018,23(3):199-206
Background
Uncertainty in the calibration of high-energy radiation sources is dependent on user and equipment type.Aim
We evaluated the uncertainty in the positioning of a cylindrical chamber at a reference depth for reference dosimetry of high-energy photon beams and the resulting uncertainty in the chamber readings for 6- and 10-MV photon beams. The aim was to investigate major contributions to the positioning uncertainty to reduce the uncertainty in calibration for external photon beam radiotherapy.Materials and methods
The following phantoms were used: DoseView 1D, WP1D, 1D SCANNER, and QWP-07 as one-dimensional (1D) phantoms for a vertical-beam geometry; GRI-7632 as a phantom for a fixed waterproofing sleeve; and PTW type 41023 and QWP-04 as 1D phantoms for a horizontal-beam geometry. The uncertainties were analyzed as per the Guide to the Expression of Uncertainty in Measurement.Results
The positioning and resultant uncertainties in chamber readings ranged from 0.22 to 0.35 mm and 0.12–0.25%, respectively, among the phantoms (using a coverage factor k = 1 in both cases). The major contributions to positioning uncertainty are: definition of the origin for phantoms among users for the 1D phantoms for a vertical-beam geometry, water level adjustment among users for the phantom for a fixed waterproofing sleeve, phantom window deformation, and non-water material of the window for the 1D phantoms for a horizontal-beam geometry.Conclusion
The positioning and resultant uncertainties in chamber readings exhibited minor differences among the seven phantoms. The major components of these uncertainties differed among the phantom types investigated. 相似文献13.
Sureyya Sarıhan Ahmet Sami Bayram Cengiz Gebitekin Omer Yerci Deniz Sıgırlı 《Reports of Practical Oncology and Radiotherapy》2018,23(2):97-104
Aim
The aim of this study was to evaluate thymic epithelial tumors (TETs) for treatment outcomes and prognostic factors on survival.Background
TETs are very rare neoplasms and multidisciplinary approach is recommended according to prognostic factors.Materials and methods
Between 1995 and 2013, 31 patients were treated with median 5400 cGy (range: 1620–6596 cGy) radiotherapy (RT). Eleven patients received adjuvant or concurrent chemotherapy. There were 25 thymomas, 4 thymic carcinomas and 2 thymic neuroendocrin carcinomas. According to Masaoka, staging and WHO classification, cases were divided to good (n: 10), moderate (n: 9) and poor (n: 12) prognostic risk groups. Survival was calculated from diagnosis.Results
In January 2016, 22 cases were alive with median 51.5 months (range: 2–170.5) follow-up. Recurrences were observed in 29% of patients in median 29.5 months (range: 6.5–105). Local control, mean overall (OS) and disease-free survival (DFS) rates were 86%, 119 and 116 months, respectively. There was a significant difference for R0 vs. R+ resection (81% vs. 43%, p = 0.06, and 69% vs. 46%, p = 0.05), Masaoka stage I–II vs. III–IV (75% vs. 52%, p = 0.001, and 75% vs. 37%, p < 0.001), and also prognostic risk groups (100% vs. 89% vs. 48%, p = 0.003, and 100% vs. 87% vs. 27%, p = 0.004) in terms of 5-year OS and DFS, respectively.Conclusion
In our study, prognostic risk stratification was shown to be a significant predictor of survival. There is a need to investigate subgroups that may or may not benefit from adjuvant RT. 相似文献14.
Objective
Gentamicin (GM) is an effective antibiotic against severe infection but has limitations related to nephrotoxicity. In this study, we investigated whether benfotiamine (BFT) and coenzyme Q10 (CoQ10), could ameliorate the nephrotoxic effect of GM in rats.Methods
Rats were divided into five groups. Group 1 and 2 served as control and sham respectively, Group 3 as GM group, Group 4 as GM + CoQ10 and Group 5 as GM + BFT for 8 days. At the end of the study, all rats were euthanized by cervical decapitation and then blood samples and kidneys were collected for further analysis. Serum urea, creatinine, cytokine TNF-a, oxidant and antioxidant parameters, as well as histopathological examination of kidney tissues were assessed.Results
Gentamicin administration caused a severe nephrotoxicity which was evidenced by an elevated serum creatinine, urea and KIM-1 level as compared with the controls. Moreover, a significant increase in serum malondialdehyde, reduced glutathione. Histopathological examination of renal tissue in gentamisin administered group, there were extremly pronounced necrotic tubules in the renal cortex and hyalen cast accumulation in the medullar tubuli. BFT given to GM rats reduced these nephrotoxicity parameters. Serum creatinine, urea, and KIM-1 were almost normalized in the GM + BFT group. Benfotiamin treatment was significantly decreased necrotic tubuli and hyalen deposition in gentamisin plus benfotiamin group. CoQ10 given to GM rats did not cause any statistically significant alterations in these nephrotoxicity parameters when compared with GM group but histopathological examination of renal tissue in GM + CoQ10 administered group, CoQ10 treatment was decreased necrotic tubuli rate and hyalen accumulation in tubuli.Conclusion
The results from our study indicate that BFT supplement attenuates gentamicin-induced renal injury via the amelioration of oxidative stress and inflammation of renal tubular cells. 相似文献15.
Ryszard Dąbrowski Izabela Drozdyk Paweł Kukołowicz 《Reports of Practical Oncology and Radiotherapy》2018,23(2):114-120
Aim
To investigate the influence of several factors on the accuracy of dose measurements and feasibility of application of small Gafchromic detectors for postal audit.Background
Our experience showed that precision of dose measurements with small pieces of Gafchromic films may be significantly improved.Materials and methods
Gafchromic films with dimensions of 1 × 1, 2 × 2 and 3 × 3 cm2 were exposed to 6 MV X-rays at dose levels of 50 cGy-210 cGy. The single- and multichannel methods (MM) were used for dose measurements. Detectors were scanned with an Epson V750PRO flatbed colour scanner. For 1 × 1 and larger detector sizes, separate calibration curves were established. The influence of the following factors was investigated: the heterogeneity of Gafchromic detectors group for single- and MM, ambient thermal detector conditions, the dose delivered on the measurement accuracy, application of two separate calibration curves for the smallest and larger pieces of films.Results
The MM improves significantly the precision of dose measurement. The uncertainty attributed to detector active layer differences and scanner instabilities was about 1 cGy (1 StDev) regardless of dose and detector size. The ambient temperature of the environment in which films were stored after irradiation influenced the dose reading. Significant difference of transmission for detectors sized 1 × 1 and 2 × 2cm2 was observed. The maximal difference between applied dose and dose reading performed was 1.1%.Conclusions
The MM with a scaling protocol leads to a very high precision of dose measurements. The ambient thermal detector environment causes significant changes of measured signal. The detector size has relevant impact on dose reading. 相似文献16.
Hamid Shafaei Douk Mahmoud Reza Aghamiri Mahdi Ghorbani Bagher Farhood Mohsen Bakhshandeh Hamid Reza Hemmati 《Reports of Practical Oncology and Radiotherapy》2018,23(2):105-113
Aim
The aim of this study is to evaluate the accuracy of the inverse square law (ISL) method for determining location of virtual electron source (SVir) in Siemens Primus linac.Background
So far, different experimental methods have presented for determining virtual and effective electron source location such as Full Width at Half Maximum (FWHM), Multiple Coulomb Scattering (MCS), and Multi Pinhole Camera (MPC) and Inverse Square Law (ISL) methods. Among these methods, Inverse Square Law is the most common used method.Materials and methods
Firstly, Siemens Primus linac was simulated using MCNPX Monte Carlo code. Then, by using dose profiles obtained from the Monte Carlo simulations, the location of SVir was calculated for 5, 7, 8, 10, 12 and 14 MeV electron energies and 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm and 25 cm × 25 cm field sizes. Additionally, the location of SVir was obtained by the ISL method for the mentioned electron energies and field sizes. Finally, the values obtained by the ISL method were compared to the values resulted from Monte Carlo simulation.Results
The findings indicate that the calculated SVir values depend on beam energy and field size. For a specific energy, with increase of field size, the distance of SVir increases for most cases. Furthermore, for a special applicator, with increase of electron energy, the distance of SVir increases for most cases. The variation of SVir values versus change of field size in a certain energy is more than the variation of SVir values versus change of electron energy in a certain field size.Conclusion
According to the results, it is concluded that the ISL method can be considered as a good method for calculation of SVir location in higher electron energies (14 MeV). 相似文献17.
Daisuke Kawahara Shuichi Ozawa Akito Saito Tomoki Kimura Tatsuhiko Suzuki Masato Tsuneda Sodai Tanaka Kazunari Hioki Takeo Nakashima Yoshimi Ohno Yuji Murakami Yasushi Nagata 《Reports of Practical Oncology and Radiotherapy》2018,23(1):50-56
Aim
Lipiodol was used for stereotactic body radiotherapy combining trans arterial chemoembolization. Lipiodol used for tumour seeking in trans arterial chemoembolization remains in stereotactic body radiation therapy. In our previous study, we reported the dose enhancement effect in Lipiodol with 10× flattening-filter-free (FFF). The objective of our study was to evaluate the dose enhancement and energy spectrum of photons and electrons due to the Lipiodol depth with flattened (FF) and FFF beams.Methods
FF and FFF for 6 MV beams from TrueBeam were used in this study. The Lipiodol (3 × 3 × 3 cm3) was located at depths of 1, 3, 5, 10, 20, and 30 cm in water. The dose enhancement factor (DEF) and the energy fluence were obtained by Monte Carlo calculations of the particle and heavy ion transport code system (PHITS).Results
The DEFs at the centre of Lipiodol with the FF beam were 6.8, 7.3, 7.6, 7.2, 6.1, and 5.7% and those with the FFF beam were 20.6, 22.0, 21.9, 20.0, 12.3, and 12.1% at depths of 1, 3, 5, 10, 20, and 30 cm, respectively, where Lipiodol was located in water. Moreover, spectrum results showed that more low-energy photons and electrons were present at shallow depth where Lipiodol was located in water. The variation in the low-energy spectrum due to the depth of the Lipiodol position was more explicit with the FFF beam than that with the FF beam.Conclusions
The current study revealed variations in the DEF and energy spectrum due to the depth of the Lipiodol position with the FF and FFF beams. Although the FF beam could reduce the effect of energy dependence due to the depth of the Lipiodol position, the dose enhancement was overall small. To cause a large dose enhancement, the FFF beam with the distance of the patient surface to Lipiodol within 10 cm should be used. 相似文献18.
Marta Kruszyna-Mochalska 《Reports of Practical Oncology and Radiotherapy》2018,23(5):309-314
Aim
The aim of the work was to catch potential errors with daily EPID measurements of repeatability of the dose distribution during irradiation of IMRT patients.Materials and methods
In the first stage, measurements were made using an anthropomorphic phantom in which the method of collecting data with an EPID device and the possibility of detecting errors in positioning were developed. Next, for 23 patients, the pelvis (P) and head and neck (H&N) regions, images were collected with an EPID device for each IMRT subfield daily and compared to reference images using the gamma method (DTA 3 mm, DD 3%). Finally, the dependencies between treatment plan parameters, pre-verification results and repeatability of collected images were evaluated.Results
The anthropomorphic phantom study has shown what kind of effects we can expect with EPID measured at potential shifts during radiotherapy. For the clinical case, score results were obtained for individual tumor regions as below: (P) 0.786 ± 1.046, (H&N) 0.720 ± 1.552. For most evaluated cases, score values were below 1%: (P) 75.5% and (H&N) 83.9% of analyzed fields. 95% of all evaluated data was with the score below: (P) 2.86% and (H&N) 3.40%. The relationship between the results of the analysis of daily collected images and the results of pre-verification, field size and irradiation time was shown.Conclusions
The EPID-based daily verification can provide extra information about day-to-day repeatability of treatment, without additional dose. 相似文献19.
Francieli Chassot Tarcieli Pozzebon Venturini Fernanda Baldissera Piasentin Janio Morais Santurio Terezinha Inez Estivalet Svidzinski Sydney Hartz Alves 《Revista iberoamericana de micología》2019,36(1):44-47
Background
Candida parapsilosis may acquire resistance to echinocandins, a fact that prompts the search for new therapeutic options.Aims
The present study aimed to evaluate the in vitro activity of antifungal agents, alone and in combination, against four groups of C. parapsilosis strains: (1) echinocandin-susceptible (ES) clinical isolates (MIC ≤ 2 μg/ml), (2) anidulafungin-resistant strains (MIC ≥ 8 μg/ml), (3) caspofungin-resistant strains (MIC ≥ 8 μg/ml), and (4) micafungin-resistant strains (MIC ≥ 8 μg/ml).Methods
Antifungal interactions were evaluated by a checkerboard micro-dilution method. The determination of the MIC to each drug for every isolate according to the Clinical and Laboratory Standards Institute documents M27 (2017) and M60 (2017) was also done.Results
The echinocandins-resistant (ER) strains showed higher MICs to the tested antifungals than the ES strains, except for amphotericin B, for which the ER groups remained susceptible.Conclusions
Most combinations showed indifferent interactions. The use of monotherapy still seems to be the best option. As resistance to echinocandins is an emergent phenomenon, further studies are required to provide clearer information on the susceptibility differences between strains to these antifungal agents. 相似文献20.
Sweta Bandanatham Janaki Manur Gururajachar Mohan Kumar Somashekar 《Reports of Practical Oncology and Radiotherapy》2018,23(2):69-74