首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
    
BackgroundSeveral authors investigated a dosimetric impact of leaf width on radiotherapy plan quality subjectively, and concluded that thinner leaf-width multileaf collimators (MLC) are beneficial because of their better coverage of clinically relevant structures. Study aimed to investigate the dosimetric effect of MLC leaf width on volumetric modulated arc therapy plan quality by objective approach.Materials and methodsTwelve of each prostate and head-and-neck patients were planned for volumetric modulated arc therapy (VMAT) treatments for MLC leaf widths of 4 mm and 10 mm. Three different VMAT schemes single-arc, dual-arc and two combined independent single-arcs were optimized. Dose volume histogram and Isodose distribution were used for quantitative and qualitative comparison of the treatment plan, respectively. Dose-volume-indices of the planning target volume, organs at risk and number of delivered monitor units were compared. The 4 mm leaf width being reference over 10 mm and results were noted as statistically significant if p ≤ 0.05 using student t-test.ResultsAll VMAT schemes for both tumor sites showed a gain in target coverage, similar organs at risk doses and higher monitor units to be delivered, when changing leaf width from 10 mm to 4 mm. The p-values were significant for majority of head-and-neck dose indices.ConclusionThe thinner-leaf MLCs, owing to their better spatial resolution, result in an overall gain for target coverage, while maintaining permissible doses to the organs at risk.  相似文献   

2.
    
PurposeTo investigate different volumetric modulated arc therapy (VMAT) field designs for lymph node positive breast cancer patients when compared to conventional static fields and standard VMAT designs.MethodsNineteen breast cancer patients with lymph node involvement (eleven left and eight right sided) were retrospectively analyzed with different arc designs. Proposed split arc designs with total rotations of 2 × 190° and 2 × 240° were compared to conventional field in field (FinF) and previously published non-split arc techniques with the same amount of total rotations.ResultsAll VMAT plans were superior in dose conformity, when compared to the FinF plans. Split arc design decreased significantly ipsilateral lung dose and heart V5Gy for both left and right sided cases, when compared to non-split VMAT designs. For left sided cases no significant differences were seen in contralateral lung mean dose or V5Gy between different VMAT designs. For right sided cases the contralateral lung dose V5Gy was significantly higher in split VMAT group, when compared to non-split VMAT designs. The contralateral breast dose V5Gy increased significantly for split VMAT plans for both sides, when compared to non-split VMAT designs or FinF plans.ConclusionsThe proposed split VMAT technique was shown to be superior to previously published non-split VMAT and conventional FinF techniques significantly reducing dose to the ipsilateral lung and heart. However, this came with the expense of an increase in the dose to the contralateral breast and for right-sided cases to the contralateral lung.  相似文献   

3.
PurposeDynamic treatment planning algorithms use a dosimetric leaf separation (DLS) parameter to model the multi-leaf collimator (MLC) characteristics. Here, we quantify the dosimetric impact of an incorrect DLS parameter and investigate whether common pretreatment quality assurance (QA) methods can detect this effect.Methods16 treatment plans with intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) technique for multiple treatment sites were calculated with a correct and incorrect setting of the DLS, corresponding to a MLC gap difference of 0.5 mm. Pretreatment verification QA was performed with a bi-planar diode array phantom and the electronic portal imaging device (EPID). Measurements were compared to the correct and incorrect planned doses using gamma evaluation with both global (G) and local (L) normalization. Correlation, specificity and sensitivity between the dose volume histogram (DVH) points for the planning target volume (PTV) and the gamma passing rates were calculated.ResultsThe change in PTV and organs at risk DVH parameters were 0.4–4.1%. Good correlation (>0.83) between the PTVmean dose deviation and measured gamma passing rates was observed. Optimal gamma settings with 3%L/3 mm (per beam and composite plan) and 3%G/2 mm (composite plan) for the diode array phantom and 2%G/2 mm (composite plan) for the EPID system were found. Global normalization and per beam ROC analysis of the diode array phantom showed an area under the curve <0.6.ConclusionsA DLS error can worsen pretreatment QA using gamma analysis with reasonable credibility for the composite plan. A low detectability was demonstrated for a 3%G/3 mm per beam gamma setting.  相似文献   

4.

Aim

To study the use of RapidArc techniques in the treatment of prostate cancer patients with hip prosthesis.

Background

An important aspect of treatment planning is to achieve dose homogeneity inside the planning target volume (PTV). Especially for those patients presenting with hip prosthesis, it becomes a challenging task to achieve dose uniformity inside the PTV.

Materials and methods

Five prostate patients presenting with hip prosthesis who had undergone radical radiotherapy were selected for this study. Depending on the composition of prosthesis, a predefined set of Hounsfield values were assigned to each study set. RapidArc plans were generated on an Eclipse treatment planning system. Two arcs that include clockwise and counter-clockwise arcs were used in all these cases. To avoid beams passing through the prosthesis, a simple structure was defined around it with 1 cm margin and a strict dose constraint applied to the block during VMAT optimization.

Results

The mean D2/D98 ratio of PTV for all the patients was 1.06 ± 0.01. The mean percentage rectum volume receiving 50 Gy, 60 Gy, 70 Gy and 75 Gy for all the patients were 33.1 ± 5.9, 21.7 ± 5.5, 13.8 ± 4.4 and 9.5 ± 3.0, respectively.

Conclusions

This study shows that using a double arc RapidArc technique is a simple and effective treatment method of treating prostate cancer in patients presenting with a hip prosthesis. The definition of a beam avoidance structure encompassing the prosthesis and applying strict dose constraints to it reduces the beam contribution to the prosthesis  相似文献   

5.
    
PurposeTo quantify the impact of simulated errors for nasopharynx radiotherapy across multiple institutions and planning techniques (auto-plan generated Volumetric Modulated Arc Therapy (ap-VMAT), manually planned VMAT (mp-VMAT) and manually planned step and shoot Intensity Modulated Radiation Therapy (mp-ssIMRT)).MethodsTen patients were retrospectively planned with VMAT according to three institution’s protocols. Within one institution two further treatment plans were generated using differing treatment planning techniques. This resulted in mp-ssIMRT, mp-VMAT, and ap-VMAT plans. Introduced treatment errors included Multi Leaf Collimator (MLC) shifts, MLC field size (MLCfs), gantry and collimator errors. A change of more than 5% in most selected dose metrics was considered to have potential clinical impact. The original patient plan total Monitor Units (MUs) were correlated to the total number of dose metrics exceeded.ResultsThe impact of different errors was consistent, with ap-VMAT plans (two institutions) showing larger dose deviations than mp-VMAT created plans (one institution). Across all institutions’ VMAT plans the significant errors included; ±5° for the collimator angle, ±5 mm for the MLC shift and +1, ±2 and ±5 mm for the MLC field size. The total number of dose metrics exceeding tolerance was positively correlated to the VMAT total plan MUs (r = 0.51, p < 0.001), across all institutions and techniques.ConclusionsDifferences in VMAT robustness to simulated errors across institutions occurred due to planning method differences. Whilst ap-VMAT was most sensitive to MLC errors, it also produced the best quality treatment plans. Mp-ssIMRT was most robust to errors. Higher VMAT treatment plan complexity led to less robust plans.  相似文献   

6.
    
PurposeTo investigate the use of dual isocenters for VMAT planning in patients with lymph node positive synchronous bilateral breast cancer (BBC) compared to a single isocenter option.MethodsTreatment plans of 11 patients with lymph node positive BBC were retrospectively analyzed using two different VMAT planning techniques: dual-isocenter split-arc VMAT plans (Iso2) were compared with mono-isocenter VMAT plans (Iso1). For Iso2 plans, PTV dose was investigated after introducing ±2 and ±5 mm couch shift errors between the two isocenters in the lateral, longitudinal and vertical direction.ResultsFor both techniques the planning aims for PTV coverage and OARs were met. The mean dose for the bilateral lungs and heart was reduced from 11.3 Gy and 3.8 Gy to 10.9 Gy (p < .05) and 3.6 Gy (p < .05), respectively, for Iso2 plans when compared to Iso1 plans. Positive statistically significant correlation (rho = 0.76, p = .006) was found between PTV volume and D2ccPTV for Iso1 plans. No clinically significant change was seen in the D98CTV or D2ccPTV after the 2 and 5 mm errors were introduced between isocenters for Iso2 plans.ConclusionsThe split arc method was shown to be a feasible treatment technique in the case of synchronous BBC for both mono and dual isocenter techniques. The dose parameters were slightly favoring dual-isocenter option instead of mono-isocenter. The dual-isocenter method was shown to be a robust treatment option in the presence of ≤5 mm errors in the shifts between the two isocenters.  相似文献   

7.
    
PurposeMeasurement-based pre-treatment verification with phantoms frequently uses gamma analysis to assess acceptable delivery accuracy. This study evaluates the sensitivity of a commercial system to simulated machine errors for three different institutions’ Volumetric Modulated Arc Therapy (VMAT) planning approaches.MethodsVMAT plans were generated for ten patients at three institutions using each institution’s own protocol (manually-planned at institution 1; auto-planned at institutions 2 and 3). Errors in Multi-Leaf Collimator (MLC) field size (FS), MLC shift (S), and collimator angle (C) of −5, −2, −1, 1, 2 and 5 mm or degrees were introduced.Dose metric constraints discriminated which error magnitudes were considered unacceptable. The smallest magnitude error treatment plans deemed clinically unacceptable (typically for a 5% dose change) were delivered to the ArcCHECK for all institutions, and with a high-dose point ion chamber measurement in 2 institutions. Error detection for different gamma analysis criteria was compared.ResultsNot all deliberately introduced VMAT plan errors were detected using a typical 3D 3%/3 mm global gamma pass rate of 95%. Considering all institutions, gamma analysis was least sensitive to negative FS errors. The most sensitive was a 2%/2 mm global analysis for institution 1, whilst for institution 2 it was 3%/3 mm global analysis. The majority of errors (58/59 for institution 1, 54/60 for institution 3) were detected using ArcCHECK and ion chamber measurements combined.ConclusionsNot all clinically unacceptable errors are detected. Combining ion chamber measurements with gamma analysis improved sensitivity and is recommended. Optimum gamma settings varied across institutions.  相似文献   

8.
    
In this study, we verified volumetric modulated arc therapy (VMAT) plans in an Elekta Synergy system with an integrated Agility 160-leaf multileaf collimator (MLC) by comparing them with Monte Carlo (MC)-calculated dose distributions using the AAPM TG-119 structure sets. The head configuration of the linear accelerator with the integrated MLC was simulated with the EGSnrc/BEAMnrc code. Firstly, the dosimetric properties of the MLC were evaluated with the MC technique and film measurements. Next, VMAT plans were created with the Pinnacle3 treatment planning system (TPS) for four regions in the AAPM TG-119 structures. They were then verified by comparing them with MC-calculated dose distributions using dose volume histograms (DVHs) and three-dimensional (3D) gamma analysis. The MC simulations for the Agility MLC dosimetric properties were in acceptable agreement with measurements. TPS-VMAT plans using TG-119 structure sets agreed with MC dose distributions within 2% in the comparison of D95 in planning target volumes (PTVs) evaluated from DVHs. In contrast, higher dose regions such as D20, D10, and D5 in PTVs for TPS tended to be smaller than MC values. This tendency was particularly noticeable for mock head and neck with complicated structures. In 3D gamma analysis, the passing rates with 3%/3mm criteria in PTVs were ≥99%, except for mock head and neck (89.5%). All passing rates for organs at risk (OARs) were in acceptable agreement of >96%. It is useful to verify dose distributions of PTVs and OARs in TPS-VMAT plans by using MC dose calculations and 3D gamma analysis.  相似文献   

9.
    
PurposeThis study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer.MethodsWe used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D95%, and D2% to planning target volume (PTV), mean dose, V50Gy, V70Gy, V75Gy, and V78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity.ResultsRP and CMO values for PTV D95%, PTV D2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V50Gy, and V70Gy to rectum were superior or comparable to CMO values; RP V75Gy and V78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 ± 55 MU and CMO: 580 ± 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 ± 0.02 and CMO: 0.35 ± 0.03 (p < 0.05).ConclusionsRP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner’s skill and knowledge.  相似文献   

10.
    
ObjectiveTo investigate the potential of Particle Swarm Optimization (PSO) for fully automatic VMAT radiotherapy (RT) treatment planning.Material and MethodsIn PSO a solution space of planning constraints is searched for the best possible RT plan in an iterative, statistical method, optimizing a population of candidate solutions. To identify the best candidate solution and for final evaluation a plan quality score (PQS), based on dose volume histogram (DVH) parameters, was introduced.Automatic PSO-based RT planning was used for N = 10 postoperative prostate cancer cases, retrospectively taken from our clinical database, with a prescribed dose of EUD = 66 Gy in addition to two constraints for rectum and one for bladder. Resulting PSO-based plans were compared dosimetrically to manually generated VMAT plans.ResultsPSO successfully proposed treatment plans comparable to manually optimized ones in 9/10 cases. The median (range) PTV EUD was 65.4 Gy (64.7–66.0) for manual and 65.3 Gy (62.5–65.5) for PSO plans, respectively. However PSO plans achieved significantly lower doses in rectum D2% 67.0 Gy (66.5–67.5) vs. 66.1 Gy (64.7–66.5, p = 0.016). All other evaluated parameters (PTV D98% and D2%, rectum V40Gy and V60Gy, bladder D2% and V60Gy) were comparable in both plans. Manual plans had lower PQS compared to PSO plans with −0.82 (−16.43–1.08) vs. 0.91 (−5.98–6.25).ConclusionPSO allows for fully automatic generation of VMAT plans with plan quality comparable to manually optimized plans. However, before clinical implementation further research is needed concerning further adaptation of PSO-specific parameters and the refinement of the PQS.  相似文献   

11.
    
PurposeThis study measured to which extent RapidPlan can drive a reduction of the human-caused variability in prostate cancer treatment planning.MethodsSeventy clinical prostate plans were used to train a RapidPlan model. Seven planners, with different levels of planning experience, were asked to plan a VMAT treatment for fifteen prostate cancer patients with and without RapidPlan assistance. The plans were compared on the basis of target coverage, conformance and OAR sparing. Inter-planner and intra-planner variability were assessed on the basis of the Plan Quality Metric formalism. Differences in mean values and InterQuartile Ranges between patients and operators were assessed.ResultsRapidPlan-assisted plans matched manual planning in terms of target coverage, homogeneity, conformance and bladder sparing but outperformed it for rectum and femoral heads sparing. 8 out of 15 patients showed a statistically significant increase in overall quality. Inter-planner variability is reduced in RapidPlan-assisted planning for rectum and femoral heads while bladder variability was constant. The inter-planner variability of the overall plan quality, IQR of PQM%, was approximately halved for all patients. RapidPlan assistance induced a larger increase in plan quality for less experienced planners. At the same time, a reduction in intra-planner variability is measured with a significant overall reduction.ConclusionsThe assistance of RapidPlan during the optimization of treatments for prostate cancer induces a significant increase of plan quality and a contextual reduction of plan variability. RapidPlan is proven to be a valuable tool to leverage the planning skills of less experienced planners ensuring a better homogeneity of treatment plan quality.  相似文献   

12.

Aim/background

To evaluate how the use of volumetric-modulated arc therapy (VMAT) with RapidArc® can improve treatment delivery efficiency based on the analysis of the beam-on times and monitor units (MU) needed to deliver therapy for multiple clinical applications in a large patient population.

Materials and methods

A total of 898 treatment courses were delivered in 745 patients treated from October 2008 to March 2013 using RapidArc® treatment plans generated in Eclipse™ TPS. All patients were treated with curative or palliative intent using different techniques including conventional fractionation (83%) and radiosurgery or SBRT (17%), depending on the clinical indications. Treatment delivery was evaluated based on measured beam-on time and recorded MU values delivered on a Varian Trilogy™ linear accelerator.

Results

For conventional fractionation treatments using RapidArc®, the delivery times ranged from 38 s to 4 min and 40 s (average 2 min and 6 s). For radiosurgical treatments the delivery times ranged from 1 min and 42 s to 9 min and 22 s (average 4 min and 4 s). The average number of MU per Gy was 301 for the entire group, with 285 for the conventional group and 317 for the radiosurgical group.

Conclusions

In this study with a large heterogeneous population, treatments using RapidArc® were delivered with substantially less beam-on time and fewer MUs than conventional fractionation. This was highly advantageous, increasing flexibility of the scheduling allowing treatment of radiosurgery patients during the regular daily work schedule. Additionally, reduction of leakage radiation dose was achieved.  相似文献   

13.
14.
    

Aim

This study compared the dosimetric impact between prostate IMRT and VMAT due to patient''s weight loss.

Background

Dosimetric variation due to change of patient''s body contour is difficult to predict in prostate IMRT and VMAT, since a large number of small and irregular segmental fields is used in the delivery.

Materials and methods

Five patients with prostate volumes ranging from 32.0 to 86.5 cm3 and a heterogeneous pelvis phantom were used for prostate IMRT and VMAT plans using the same set of dose–volume constraints. Doses in IMRT and VMAT plans were recalculated with the patient''s and phantom''s body contour reduced by 0.5–2 cm to mimic size reduction. Dose coverage/criteria of the PTV and CTV and critical organs (rectum, bladder and femoral heads) were compared between IMRT and VMAT.

Results

In IMRT plans, increases of the D99% for the PTV and CTV were equal to 4.0 ± 0.1% per cm of reduced depth, which were higher than those in VMAT plans (2.7 ± 0.24% per cm). Moreover, increases of the D30% of the rectum and bladder per reduced depth in IMRT plans (4.0 ± 0.2% per cm and 3.5 ± 0.5% per cm) were higher than those of VMAT (2.2 ± 0.2% per cm and 2.0 ± 0.6% per cm). This was also true for the increase of the D5% for the right femoral head in a patient or phantom with size reduction due to weight loss.

Conclusions

VMAT would be preferred to IMRT in prostate radiotherapy, when a patient has potential to suffer from weight loss during the treatment.  相似文献   

15.
    
PurposeTo analyse the impact of different optimization strategies on the compatibility between planned and delivered doses during radiotherapy of cervical cancer.Material/methodsFour treatment plans differing in optimisation strategies were prepared for ten cervical cancer cases. These were: volumetric modulated arc therapy with (_OPT) and without optimization of the doses in the bone marrow and for two sets of margins applied to the clinical target volume that arose from image guidance based on the bones (IG(B)) and soft tissues (IG(ST)). The plans were subjected to dosimetric verification by using the ArcCHECK system and 3DVH software. The planned dose distributions were compared with the corresponding measured dose distributions in the light of complexity of the plans and its deliverability.ResultsThe clinically significant impact of the plans complexity on their deliverability is visible only for the gamma passing rates analysis performed in a local mode and directly in the organs. While more general analyses show statistically significant differences, the clinical relevance of them has not been confirmed. The analysis showed that IG(ST)_OPT and IG(B)_OPT significantly differ from IG(ST) and IG(B). The clinical acceptance of IG(ST)_OPT obtained for hard combinations of gamma acceptance criteria (2%/2 mm) confirm its satisfactory deliverability. In turn, for IG(B)_OPT in the case of the rectum, the combination of 2%/2 mm did not meet the criteria of acceptance.ConclusionDespite the complexity of the IG(ST)_OPT, the results of analysis confirm the acceptance of its deliverability when 2%/2 mm gamma acceptance criteria are used during the analysis.  相似文献   

16.
X线机设备结构复杂,控制繁琐,导致可靠性较差;而控制器局域网络(Controller Area Network,CAN)具有实时性强、可靠性高、通信速率快、结构简单,总线协议具有完善的错误处理机制、灵活性高等特点。由此本文提出一种基于CAN总线结构的X线机设计方案,并实现了基于CAN的束光器控制器的设计。基于CAN总线结构的X线机不仅减少了硬件的接口和通信线,而且能提高设备模块之间的数据交换能力和设备的抗干扰能力,并改善设备的性能。  相似文献   

17.
赵金早  庄永志 《生物磁学》2009,(15):2910-2912
目的:医用直线加速器矩形野散射因子计算方法加以改进。方法:(1)实际测量矩形野的散射因子;(2)利用Kim的经验公式和面积-周长比公式分别计算理论上的矩形野的散射因子,并与矩形野的测量结果进行比较。结果:采用该方法计算医用加速器散射因子的最大误差在0.5%以下,而采用面积-周长比原理确定的等效方边长,最大误差达到3%左右。结论:采用Kim计算方法算出的等效边长,然后再根据矩形野测量出的数据计算等效射野的Scp结果比传统的面积周长比算法更能减小计算误差,并且精度也比较高。  相似文献   

18.
In typical treatment planning of 3D IMRT, the incident energy fluence is optimized to achieve a homogeneous dose distribution to the PTV. The PTV includes the tumour but also healthy tissues that may have a different dose response for the same incident energy fluence, like bony structures included in the PTV (mandibles in head and neck tumours or femoral bones in sarcomas). Dose to medium optimization compensates for this heterogeneous response, leading to a non-homogeneous energy fluence in the PTV and a non-homogeneous dose in the CTV in the presence of geometric errors. We illustrate qualitatively this statement in a cylindrical geometry where the PTV includes a CTV (7 cm diameter) made of water surrounded by ICRU compact bone (1.2 cm thickness); such configuration was chosen to exaggerate the aforementioned effect. Optimization was performed assuming dose equals photon energy fluence times mass energy absorption coefficient. Bone has a 4% lower dose response in a 6 MV flattening filter free spectrum. After optimization either in medium or assuming everything as water composition, the geometry was shifted by 1.2 cm and dose recomputed. As expected, compensating for the under-response of the bone material during optimization in medium leads to an overdosage of the CTV when patient geometric errors are taken into account. Optimization in dose assuming everything as water composition leads to a uniform coverage. Robust optimization or forcing a uniform atomic composition in the PTV margin may resolve this incompatibility between the PTV concept and dose to medium optimization.  相似文献   

19.

Aim

To report outcomes for patients with para-aortic lymph node positive cervical cancer treated with a dynamic field-matching technique.

Background

PET staging of cervical cancer has increased identification of patients with para-aortic lymph node metastasis. IMRT enables dose escalation in this area, but matching IMRT fields with traditional whole pelvis fields presents a challenge.

Materials and methods

From 2003 to 2012, 20 patients with cervical cancer and para-aortic lymph node metastasis were treated utilizing the dynamic field-matching technique. As opposed to single-isocenter half-beam junction techniques, this technique employs wedge-shaped dose junctions for the abutment of fields. We reviewed the records of all patients who completed treatment with the technique and abstracted treatment, toxicity, and disease-related outcome data for analysis.

Results

Median prescribed dose to the whole pelvis field was 45 Gy and para-aortic IMRT field 50.4 Gy. All but 3 patients underwent HDR (13 pts) or LDR (4 pts) brachytherapy. All patients developed lower GI toxicity; 10 grade 1, 9 grade 2, and 1 grade 4 (enterovaginal fistula). Median DFS was 12.4 months with 1 and 2-year DFS 60.0% and 38.1%. One-year OS was 83.7% and 2-year OS, 64.4%. A total of 10 patients developed recurrence; none occurred at the matched junction.

Conclusions

The dynamic field-matching technique provides a means for joining conventional whole pelvis fields and para-aortic IMRT fields that substantially reduces dose deviations at the junction due to field mismatch. Treatment with the dynamic matching technique is simple, effective, and tolerated with no apparent increase in toxicity.  相似文献   

20.

Background and aim

This study proposed a method to estimate the beam-on time for prostate cancer patients treated on Tomotherapy when FW (field width), PF (pitch factor), modulation factor (MF) and treatment length (TL) were given.

Material and methods

The study was divided into two parts: building and verifying the model. To build a model, 160 treatment plans were created for 10 patients. The plans differed in combination of FW, PF and MF. For all plans a graph of beam-on time as a function of TL was created and a linear trend function was fitted. Equation for each trend line was determined and used in a correlation model. Finally, 62 plans verified the treatment time computation model – the real execution time was compared with our estimation and irradiation time calculated based on the equation provided by the manufacturer.

Results

A linear trend function was drawn and the coefficient of determination R2 and the Pearson correlation coefficient r were calculated for each of the 8 trend lines corresponding to the adequate treatment plan. An equation to correct the model was determined to estimate more accurately the beam-on time for different MFs. From 62 verification treatment plans, only 5 disagreed by more than 60 s with the real time from the HT software. Whereas, for the equation provided by the manufacturer the discrepancy was observed in 16 cases.

Conclusions

Our study showed that the model can well predict the treatment time for a given TL, MF, FW and it can be used in clinical practice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号