首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Evaluation of Disinfectants for Hospital Housekeeping Use   总被引:3,自引:1,他引:2       下载免费PDF全文
A use-dilution procedure and screening method are proposed to aid the hospital bacteriologist in selecting the most effective disinfectants. Sixteen disinfectants were tested with and without organic material on six different organisms. Sporadic results usually obtained with quaternaries tested by the procedure of the Association of Official Agricultural Chemists (AOAC) were eliminated by the methods of this study. The use-dilution procedure employs the material upon which the disinfectant is to be used, rather than stainless steel, as in the AOAC use-dilution test. The importance of testing each disinfectant against several organisms and in the presence of organic material is discussed.  相似文献   

2.
The effect of a phenolic disinfectant ( o -phenylphenol 45% w/w) with linseed oil soap or with soya oil soap on Mycobacterium tuberculosis was determined by three methods. Neither the geometrical dilution test nor the modified capacity use-dilution test revealed any differences between the two disinfectants. However, paradoxically both methods proved that the highest concentration of the disinfectants tested (3·5% v/v) exhibited a very low germicidal effect on M. tuberculosis , whereas lower concentrations showed a much better effect. When determining the tuberculocidal effects of various concentrations of the two disinfectants at different exposure times, the higher concentrations showed very low effects, even after the longest exposure time. At concentrations of 2·0 and 1·0% (v/v), the disinfectants displayed the most rapid effects. In the present investigation the disinfectant with the linseed oil soap seemed to destroy the cells more quickly than that with the soya oil soap. The third disinfectant containing p -chloro- m -cresol and o -benzyl- p -chlorophenol with a total of 9·2% (w/w) phenols in a detergent system, did not display, when employing the capacity use-dilution test, the same phenomenon in the concentrations used, but the experiment showed that the recommended use-dilution concentration ought to be doubled.  相似文献   

3.
Use-Dilution Test and Newcastle Disease Virus   总被引:2,自引:2,他引:0       下载免费PDF全文
The use-dilution test for evaluating the effectiveness of disinfectants against bacteria was modified to determine the effectiveness of disinfectants against a group of viruses. Modifications were kept to a minimum to retain the general principles of the test and thereby retain the test's familiarity among testing laboratory personnel. Modifications included the use of a standard allantoic fluid suspension of Newcastle disease virus instead of a standard bacterial culture. The only other modification was the inoculation of six embryonated chicken eggs (10 to 12 days old) with 0.1 ml of nutrient broth into which a carrier ring was transferred after a standard period in diluted disinfectant. The death or survival of 60 embryos, then, is the criterion by which a disinfectant can be judged effective at use-dilution. Experiments are described which establish the validity of the modified test procedure. The effectiveness of nine common disinfectants against Newcastle disease virus as judged by this test procedure is reported.  相似文献   

4.
In-use testing of disinfectants is necessary to ensure efficacy over time. The current official procedure for testing disinfectants, the Association of Official Analytical Chemists (AOAC) use-dilution method, cannot be adapted to repeated sampling techniques of use-life testing. It is therefore necessary to use an alternative method when evaluating the activity of a disinfectant under actual use. The Clinical Research Associates (CRA) suspension method was developed to fill this need. It consists of adding 0.5 ml of a standard culture to 5.0 ml of test disinfectant and sampling the mixture after 10 min for surviving bacteria. When this test was compared with the AOAC use-dilution method under a simulated use situation, the two methods were generally equivalent in identifying disinfectant inactivation. In addition, the CRA method was less time consuming, easier to perform, and less variable than the AOAC method. Use of the CRA method in a clinical study demonstrated the need for reuse claims to be based on clinical use studies rather than on laboratory testing only.  相似文献   

5.
In-use testing of disinfectants is necessary to ensure efficacy over time. The current official procedure for testing disinfectants, the Association of Official Analytical Chemists (AOAC) use-dilution method, cannot be adapted to repeated sampling techniques of use-life testing. It is therefore necessary to use an alternative method when evaluating the activity of a disinfectant under actual use. The Clinical Research Associates (CRA) suspension method was developed to fill this need. It consists of adding 0.5 ml of a standard culture to 5.0 ml of test disinfectant and sampling the mixture after 10 min for surviving bacteria. When this test was compared with the AOAC use-dilution method under a simulated use situation, the two methods were generally equivalent in identifying disinfectant inactivation. In addition, the CRA method was less time consuming, easier to perform, and less variable than the AOAC method. Use of the CRA method in a clinical study demonstrated the need for reuse claims to be based on clinical use studies rather than on laboratory testing only.  相似文献   

6.
The Association of Official Analytical Chemists bacterial use-dilution test for evaluating liquid surface disinfectants was modified to determine the efficacy of three common environmental germicide compounds against representatives of four virus groups. Modifications were made to conform to the Environmental Protection Agency guidelines on virucidal testing procedures. Alterations included: the use of a concentrated tissue culture preparation of virus instead of a standard bacterial culture; HEp-2 tissue culture cells as a visible test system in place of standard nutrient broth; and controls to measure the virus titer end point and the toxicity of the disinfectant to the cell cultures. Comparison of control end points with results from the test proper were the measure of the effectiveness of the germicides against the viruses. Results are described which agree with those based on other methods previously reported.  相似文献   

7.
Neutralization of the activity of eight disinfectants by organic matter   总被引:3,自引:0,他引:3  
The effect of organic matter on the activity of eight disinfectants was evaluated. Three types of interfering substrates (whole milk powder, dried beef blood and fish meal) were tested according to the method of Whitmore and Miner adapted to the AOAC use-dilution method. Glutaraldehyde and to a certain extent, chlorhexidine acetate and the amphoteric surfactant kept their disinfecting activity after contact with high concentrations of organic matter. The quaternary ammonium compound as well as the quaternary ammonium-glutaraldehyde complex were more readily neutralized whereas anionic acid, iodophor and sodium hypochlorite did not tolerate the presence of organic matter. The neutralizing activity of powders was correlated to their solubility and composition.  相似文献   

8.
Two methods, a capacity use-dilution test and another employing geometrical dilution, are used when comparing the bactericidal and fungicidal effects of a phenolic disinfectant containing 45% (w/w) o -phenylphenol in an aqueous soap solution of linseed oil (soap content 6·5% w/v) with the corresponding effects of the same phenolic compound in an aqueous soya oil soap solution (soap content 3·5% w/v). The soya oil soap did not change the disinfectant capacity on the different test organisms used. For the most resistant strain ( Staphylococcus aureus ) the usedilution concentration was evaluated to be slightly above 1%, i.e. 2%, which is much lower than the recommended use-dilution concentration. However, using the same method and test organisms the capacity use-dilution testing of a third phenolic disinfectant, containing p -chloro- m -cresol and o -benzyl- p -chlorophenol with a total of 9·2 (w/w) phenols in a detergent system, indicated that the recommended use-dilution concentration should be doubled.  相似文献   

9.
Pseudomonas aeruginosa ATCC 15442 is a required organism in the Association of Official Analytical Chemists use-dilution method for disinfectant efficacy testing. When grown in a liquid medium, P. aeruginosa produces a dense mat or pellicle at the broth/air interface. The purpose of this investigation was to examine the pellicle by scanning electron microscopy, to evaluate three pellicle removal methods, and to determine the effect of pellicle fragments on disinfectant efficacy test results. The efficacies of three methods of pellicle removal (decanting, vacuum suction, and filtration) were assessed by quantifying cell numbers on penicylinders. The Association of Official Analytical Chemists use-dilution method was used to determine whether pellicle fragments in the tubes used to inoculate penicylinders affected test results. Scanning electron micrographs showed the pellicle to be a dense mass of intact, interlacing cells at least 10 microns thick. No significant differences in pellicle removal methods were observed, and the presence of pellicle fragments usually increased the number of positive tubes in the use-dilution method significantly.  相似文献   

10.
Pseudomonas aeruginosa ATCC 15442 is a required organism in the Association of Official Analytical Chemists use-dilution method for disinfectant efficacy testing. When grown in a liquid medium, P. aeruginosa produces a dense mat or pellicle at the broth/air interface. The purpose of this investigation was to examine the pellicle by scanning electron microscopy, to evaluate three pellicle removal methods, and to determine the effect of pellicle fragments on disinfectant efficacy test results. The efficacies of three methods of pellicle removal (decanting, vacuum suction, and filtration) were assessed by quantifying cell numbers on penicylinders. The Association of Official Analytical Chemists use-dilution method was used to determine whether pellicle fragments in the tubes used to inoculate penicylinders affected test results. Scanning electron micrographs showed the pellicle to be a dense mass of intact, interlacing cells at least 10 microns thick. No significant differences in pellicle removal methods were observed, and the presence of pellicle fragments usually increased the number of positive tubes in the use-dilution method significantly.  相似文献   

11.
Factors Affecting the Activity of Phenolic Disinfectants   总被引:1,自引:1,他引:0       下载免费PDF全文
Low challenge phenol coefficient and high challenge use-dilution tests were made on a neutral cocoanut oil soap emulsion of o-phenylphenol and aqueous solutions of sodium o-phenylphenate prepared in the laboratory from the phenol using a stoichiometric amount of NaOH as well as with increasing amounts of excess NaOH. The phenol had considerably greater activity in both test methods when emulsified with the neutral soap than when converted to the phenate and dissolved in water. Use dilution test results against Salmonella choleraesuis with both the phenol and the phenate were within the range which would have been predicted from the Salmonella typhosa coefficient results employing the conventional conversion multiple of 20 to determine the maximal number of parts of water to which one part of germicide could be added. With the emulsified phenol this was also true where Staphylococcus aureus was employed in both procedures. With the aqueous solution of the phenate the maximal safe use-dilution by the phenol coefficient found for S. aureus and the same conventional conversion procedure was roughly five times higher than the maximal safe use-dilution found by the use-dilution method. Results with aqueous solutions of the phenate to which increasing amounts of excess NaOH were added showed no significant differences in the phenol coefficient method with either S. typhosa or S. aureus. In the use-dilution method, significant decreases in activity were found as the excess NaOH was increased to 4% with both S. choleraesuis and S. aureus. Although the pH values of aqueous solutions of the phenate were raised as the amount of free NaOH was increased, the decreases in pH observed as the dilution with water was increased were such that only small differences existed at the high critical killing dilutions found in the low challenge phenol coefficient method, whereas rather large differences existed at the lower critical killing dilutions in the high challenge use-dilution method.  相似文献   

12.
Although all disinfectant tests have the same final purpose, namely measuring the antimicrobial activity of a chemical substance or preparation, a large number of testing methods has been described. They are subdivided into suspension tests, carrier and surface disinfection tests and other practice-mimicking tests. The suspension tests comprise qualitative and quantitative suspension tests, and, as derived tests, the determination of the phenol coefficient and capacity tests. There is an essential difference between a carrier test and a surface disinfectant test: in the former case the carrier is submerged in the disinfectant solution during the whole exposure time, whereas in the latter case the disinfectant is applied on the carrier for the application time and thereafter the carrier is drying during the exposure.The basic principle now widely accepted is that the antimicrobial efficiency of a disinfectant is examined at three stages of testing.The first stage concerns laboratory tests in which it is verified whether a chemical compound or a preparation possesses antimicrobial activity. For these preliminary screening tests, suspension tests are considered.In the second stage of tests, disinfection procedures and not disinfectants are examined. It is determined under which conditions and at which use-dilution for a given application the preparation is active: the tests simulate real-life situations; such tests are carrier tests for the disinfection of materials by submersion and surface disinfection tests.The last stage takes place in the field, and comprises the in-loco or in-situ tests with as variants the in-use tests, which examine whether, after a normal period of use, germs are still killed by the disinfectant solution.It is the task of the European and international standardization organisations to develop new standards and to elaborate tests, which predict the effectiveness of a preparation in practice under variable circumstances.  相似文献   

13.
The bactericidal activity of a general purpose disinfectant consisting of 25% sodium-o-phenylphenolate and 75% sodium-4- and 6-chloro-2-phenylphenolate was evaluated by a simulated in-use, surface-square dilution method. Common floor (asphalt, rubber, and unglazed tiles) and wall (stainless steel tile, ceramic tile, and painted wood) surfaces of various porosities and compositions were selected to simulate actual-use conditions.

The method used consisted of inoculating the surfaces of 1-in. square sections of floor and wall covering with a test organism, air-drying the inoculated surface, applying the disinfectant, allowing it to act for 10 min, and recovering the survivors by plating. Confirmatory results of the standard phenol coefficient and use-dilution tests indicated 700 ppm of the disinfectant to be a safe use concentration. The in-use surface-square dilution studies have shown that this is a more than adequate safe concentration for stainless steel, both glazed and unglazed ceramic tile, and nonwaxed surface of asphalt tile. However, concentrations ranging between 2,500 and 6,000 ppm for plastic-fortified rubber tile, 1,500 and 2,000 ppm for waxed asphalt tile, and 2,000 ppm for painted wood were required to achieve 99.9% reduction of either Salmonella choleraesuis or Salmonella schottmuelleri. These results indicate that a disinfectant concentration derived from the Association of Official Agricultural Chemists use-dilution test cannot always be relied upon to provide a dependable index to actual safe use-dilution when a disinfectant is supplied to certain wall or floor surfaces.

  相似文献   

14.
Aims:  To evaluate disinfectants against Salmonella under conditions relevant for the feed industry.
Materials and Results:  A survey on the use of disinfectants in feed industry showed that a range of different types was used. Nine disinfectants, reflecting the most commonly used active ingredients, were tested for bactericidal activity on Salmonella isolated from the feed industry. All disinfectants were efficient against Salmonella in suspension. The bactericidal effect varied considerably between different types of active compounds on bacteria dried on surfaces or grown as biofilm. Tenside-based disinfectants and hypochlorite were found to have low bactericidal activity and the efficiency was significantly reduced when the ratio of amount disinfectant per cell decreased. It was shown that concentrations of 70–80% ethanol were effective against Salmonella. Among the disinfectants tested a product containing 70% ethanol was most efficient followed by Virkon S.
Conclusions:  Many disinfectants had low bactericidal activity against Salmonella at surfaces while Virkon S and a product containing 70% ethanol were most effective. Another advantage of ethanol-based disinfectants is evaporation of ethanol, resulting in low residual water after use.
Significance and Impact of the Study:  Use of the disinfectants found to be efficient against surface associated Salmonella , may assist the industry in combating Salmonella .  相似文献   

15.
Aims: To compare the susceptibility of a 3‐day‐old biofilm and planktonic Salmonella to disinfectants at different exposure times. We hypothesize that Salmonella biofilms are more resilient to disinfectants compared to planktonic Salmonella. Methods and Results: The susceptibility of planktonic cells to disinfectants was tested by a modified version of the Council of Europe suspension test EN 1276. Salmonella biofilms were formed using the Calgary Biofilm Device. Results show that 3‐day‐old Salmonella biofilms are less susceptible to the disinfectants benzalkonium chloride, chlorhexidine gluconate, citric acid, quaternary ammonium compounds, sodium hypochlorite (SH) and ethanol, compared to planktonic Salmonella. Surprisingly, the results also demonstrate that low concentrations of SH were more effective against a 3‐day‐old biofilm compared to high concentrations of SH. Conclusions: While all the disinfectants evaluated were able to reduce biofilm‐associated cells at concentrations and contact times sufficient to eliminate planktonic cells, there were still sufficient viable cells remaining in the biofilm to cause further contamination and potential infection. Significance and Impact of the Study: Protocols for the use of chemical disinfectants need to include biofilm susceptibility testing. There is a requirement for an effective and standardized tool for determining the susceptibility of biofilms to disinfectants.  相似文献   

16.
AIMS: The aim of this study was to determine if three classes of farm disinfectants were able to select for ciprofloxacin or cyclohexane tolerant [indicative of a multiple antibiotic resistance (MAR) phenotype] Escherichia coli and if cyclohexane-tolerant E. coli could be isolated from farms. METHODS AND RESULTS: Chicken slurry containing ca 1 : 99 ratio ciprofloxacin resistant : susceptible E. coli (10 different resistant strains examined) was treated for 24 h with each of the disinfectants and examined for survival of resistant : susceptible strains. Ciprofloxacin-sensitive (n=5) and -resistant (n=5) E. coli were grown with sublethal concentrations of the disinfectants and then plated to agar containing ciprofloxacin or overlaid with cyclohexane. Escherichia coli (n=389) isolated from farms were tested for cyclohexane tolerance. Minimum inhibitory concentrations (MIC) were determined against representative isolates and mutants. The disinfectants did not select for the ciprofloxacin-resistant E. coli in poultry slurry but following growth with each of the three disinfectants, higher numbers (P < or = 0.023) of cyclohexane-tolerant E. coli were isolated and these had a MAR phenotype. Of the 389 farm E. coli tested, only one was cyclohexane tolerant. CONCLUSIONS: It is possible that in a farm environment, E. coli could be exposed to similar concentrations of the disinfectants that are selected for MAR type organisms under these laboratory conditions. SIGNIFICANCE AND IMPACT OF THE STUDY: Data from this study suggest that cyclohexane-resistant E. coli are not common on farms, but in view of the ease of isolating them in the laboratory with farm disinfectants, further investigations on farms are warranted.  相似文献   

17.
AIMS: The aim of this study is to identify common household disinfectants that combine significant activity against the type orthopoxvirus, vaccinia virus with minimal impact in terms of potential toxicity and/or damage to household or personal items. METHODS AND RESULTS: Laboratory scale experiments assessed common disinfectants containing anionic and nonionic detergents, oxygen-based bleach, potassium peroxomonosulfate, chloroxylenol or halogenated phenols. Disinfectants were assessed for their ability to inactivate the virus on contact or after a short incubation period in the presence and absence of foetal bovine serum as a potential interferant. Significant differences were observed ranging from negligible effect of detergents to complete inactivation on contact with chloroxylenol. CONCLUSIONS: At least one chloroxylenol-based household disinfectant is available, which inactivates vaccinia virus on contact. SIGNIFICANCE AND IMPACT OF THE STUDY: In the event of a release or major outbreak of a pathogenic orthopoxvirus there is likely to be significant public demand for disinfectants with activity against these viruses. The identification of common household disinfectants with such activity obviates any requirement to stockpile or distribute laboratory/industrial disinfectants for this purpose.  相似文献   

18.
AIMS: To determine the sensitivity of a strain used for disinfectants testing (Pseudomonas aeruginosa ATCC 15442) and food-associated isolates to benzalkonium chloride and didecyl dimethylammonium chloride (DDAC). To determine whether the increase in bacterial resistance after adaptation to DDAC can be associated with phenotypic changes. To test the activity of alternative disinfectants to eliminate resistant Pseudomonas spp. METHODS AND RESULTS: Pseudomonas aeruginosa ATCC 15442 was among the most resistant strains tested using a bactericidal suspension test. Growth of a sensitive Ps. fluorescens in gradually higher concentrations of DDAC resulted in stable higher resistance and to some cross-resistance to several antibacterial agents, with the exception of disinfectants containing chloramine T, glutaraldehyde or peracetic acid. It was shown by microscopy that adaptation was followed by loss of flagella, and slime formation. Removal of the slime by sodium dodecyl sulphate resulted in partial loss of the acquired resistance. CONCLUSIONS: Pseudomonas spp. may adapt to survive against higher concentrations of quaternary ammonium compounds (QACs), but resistant strains can be eliminated with chemically unrelated disinfectants. SIGNIFICANCE AND IMPACT OF THE STUDY: The work supports the rotation of disinfectants in food processing environments for avoiding the development of bacterial resistance to QACs. The alternating disinfectants should be chosen carefully, because of possible cross-resistance.  相似文献   

19.
Aims:  To determine if Listeria monocytogenes persistent strains differ from presumed nonpersistent strains in disinfection susceptibility and to examine the influence of attachment and NaCl on susceptibility.
Methods and Results:  Two model-systems that allowed quantitative inter-strain comparison of disinfectant sensitivity were developed. Persistent L. monocytogenes were not more tolerant to the disinfectants Incimaxx DES and Triquart SUPER than presumed nonpersistent isolates. When calibrating the systems with respect to presence of biological material and cell density, attached bacteria were as sensitive to disinfectants as were planktonic bacteria. Growth with 5% NaCl increased the tolerance of planktonic cells to Incimaxx DES. All strains of spot inoculated L. monocytogenes survived well 20 h of drying when protected by growth media and 5% NaCl, but were not protected by NaCl against disinfection.
Conclusions:  Persistent strains of L. monocytogenes are as susceptible to disinfectants as are presumed nonpersistent strains and attachment does not render the strains more tolerant to disinfectants. Growth with NaCl affected the susceptibility of the planktonic L. monocytogenes to Incimaxx DES and protected spot inoculated cells during drying.
Significance and Impact of the Study:  Attachment to surfaces does not per se offer protection to L. monocytogenes against disinfectants and disinfection tolerances do not appear to influence the ability of a strain to persist.  相似文献   

20.
Aims: To study a possible effect of a synthetic brominated furanone on biofilm formation and biofilm resistance to disinfectants in Salmonella enterica. Methods and Results: The effect of a synthetic furanone on biofilm formation of Salm. enterica serovar Agona and Salm. enterica serovar Typhimurium (11 strains of different origins) was evaluated in a microtiterplate assay. A significant reduction in biofilm build‐up in microtiterplates by the furanone was observed for seven of the strains tested. Biofilms by two Salm. Agona feed factory strains and the effects on survival after exposures to disinfectants (hypochlorite and benzalkonium chloride) were assessed for both strains. Pretreatment with furanone significantly potentiated the effect of the two disinfectants for both strains. Conclusions: The effect of disinfectants on Salmonella in biofilm was significantly enhanced when the biofilm was grown in the presence of furanone. This was probably because of an effect on biofilm architecture, composition and in some cases also biofilm build‐up. Significance and Impact of the Study: The present study gives valuable new knowledge in the fight against Salmonella biofilm in the environment because of the potentiated effect of conventional disinfectants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号