1.
The success of stents to restore blood flow in atherosclerotic peripheral arteries is low relative to coronary arteries. It has been shown that joint flexion induces a mechanical environment that makes stent placement in these arteries highly incompatible, and damage and destruction of stents has been recorded. However, the effect of this environment on the stresses in the arteries is unknown. It is hypothesised that the stresses induced in arteries as a result of this mechanical environment could be sufficient to explain the relatively low success rates. To investigate this hypothesis, a finite element model of the stent-artery interaction was developed. Following stent expansion, bending was simulated by applying a displacement boundary condition to the artery. It is found that high stresses occur at the proximal/distal ends of the stent. As high stress and vascular injury are hypothesised to cause restenosis, the results presented here suggest that the mechanical environment of peripheral arteries could be the predominant cause of high restenosis rates.  相似文献   

2.
The effectiveness of a cardiovascular stent depends on many factors, such as its ability to sustain the compression applied by the vessel wall, minimal longitudinal contraction when it is expanded, and its ability to flex when navigating tortuous blood vessels. The long-term reaction of the tissue to the stent is also device dependant; in particular some designs provoke in-stent restenosis (i.e., regrowth of the occlusion around the stent). The mechanism of restenosis is thought to involve injury or damage to the vessel wall due to the high stresses generated around the stent when it expands. Because of this, the deflection of the tissue between the struts of the stent (called prolapse or "draping") has been used as a measure of the potential of a stent to cause restenosis. In this paper, uniaxial and biaxial experiments on human femoral artery and porcine aortic vascular tissue are used to develop a hyperelastic constitive model of vascular tissue suitable for implementation in finite-element analysis. To analyze prolapse, four stent designs (BeStent 2, Medtronic AVE; NIROYAL, Boston Scientific; VELOCITY, Cordis; TETRA, Guidant) were expanded in vitro to determine their repeating-unit dimensions. This geometric data was used to generate a finite element model of the vascular tissue supported within a repeating-unit of the stent. Under a pressure of 450 mm Hg (representing the radial compression of the vessel wall), maximum radial deflection of 0.253 mm, 0.279 mm, 0.348 mm and 0.48 mm were calculated for each of the four stents. Stresses in the vascular wall were highest for the VELOCITY stent. The method is proposed as a way to compare stents relative to their potential for restenosis and as a basis for a biomechanical design of a stent repeating-unit that would minimize restenosis.  相似文献   

3.
Since their first introduction, stents have revolutionised the treatment of atherosclerosis; however, the development of in-stent restenosis still remains the Achilles' heel of stent deployment procedures. Computational modelling can be used as a means to model the biological response of arteries to different stent designs using mechanobiological models, whereby the mechanical environment may be used to dictate the growth and remodelling of vascular cells. Changes occurring within the arterial wall due to stent-induced mechanical injury, specifically changes within the extracellular matrix, have been postulated to be a major cause of activation of vascular smooth muscle cells and the subsequent development of in-stent restenosis. In this study, a mechanistic multi-scale mechanobiological model of in-stent restenosis using finite element models and agent-based modelling is presented, which allows quantitative evaluation of the collagen matrix turnover following stent-induced arterial injury and the subsequent development of in-stent restenosis. The model is specifically used to study the influence of stent deployment diameter and stent strut thickness on the level of in-stent restenosis. The model demonstrates that there exists a direct correlation between the stent deployment diameter and the level of in-stent restenosis. In addition, investigating the influence of stent strut thickness using the mechanobiological model reveals that thicker strut stents induce a higher level of in-stent restenosis due to a higher extent of arterial injury. The presented mechanobiological modelling framework provides a robust platform for testing hypotheses on the mechanisms underlying the development of in-stent restenosis and lends itself for use as a tool for optimisation of the mechanical parameters involved in stent design.  相似文献   

4.
Wu W  Qi M  Liu XP  Yang DZ  Wang WQ 《Journal of biomechanics》2007,40(13):3034-3040
Carotid angioplasty and stenting (CAS) has emerged as an effective alternative to carotid endarterectomy, and nitinol stents are commonly used in CAS. To evaluate biomechanical properties of nitinol carotid stents and their interactions with carotid arteries, a finite element method (FEM) model was built which is composed of a stenotic carotid tissue, a segmented-design nitinol stent and a sheath. Two different stents were considered to show the influence of stent design on the stent-vessel interactions. Results show that the superelastic stents were delivered into the stenotic vessel lumen through the sheath and self-expanded in the internal and common carotid artery. The stent with shorter struts may have better clinical results and the different stent designs can cause different carotid vessel geometry changes. This FEM can provide a convenient way to test and improve biomechanical properties of existing carotid stents and give clues for new nitinol carotid stent designs.  相似文献   

5.
Balloon-expandable and self-expandable stents are the two types of coronary stents available. Basically, they differ in the modality of expansion.The present study analyses the stress state induced on the vascular wall, by the expansion of balloon- and self-expandable stents, using the finite element method. Indeed, modified mechanical stress state is in part responsible in the restenosis process. The balloon-expandable stents herein investigated are assumed to be made of stainless steel, while the self-expandable stents are made of a shape memory alloy. The effects of the severity of the coronary stenosis, the atherosclerotic plaque stiffness and the stent design are investigated. Comparing the self-expandable stent with the balloon-expandable one, the former induces fewer stresses and lower damage to the vessel, but, on the other hand, its lower stiffness induces a lower capability to restore vasal lumen and to contrast arterial elastic recoil.  相似文献   

6.
Advances in the treatment of coronary artery disease have seen a significant drop in mortality and morbidity particularly amongst patients with acute myocardial infarction (MI). In particular, percutaneous trans-luminal balloon angioplasty (PTCA) with stenting to re-open atherosclerotic coronary arteries has yielded marked improvement in clinical outcome for patients with acute MI. Furthermore, with the advent of drug-eluting stents occurrence rates for coronary artery restenosis, one common clinical problem associated with angioplasty and stent deployment, have declined markedly. However, coronary restenosis in diabetic patients remains an on-going problem. The success of drug-eluting stents has seen a renewed focus on myocardial ischaemia reperfusion (IR) injury as this represents one area of research where many questions remain unanswered. In particular, the relationship between myocardial IR injury and decreased myocardial micro-vasculature re-flow post PTCA (that ultimately leads to poor clinical outcome and myocardial damage/dysfunction) is one area of research with the potential to decrease current complication rates further in patients suffering myocardial IR injury sustained during MI. This review discusses the role for oxidative stress, oxidant source(s) and both gene regulation and stem-cell therapy as potential strategic targets in the ischaemic myocardium, with the ultimate aim of providing significant cardioprotection in the setting of acute MI.  相似文献   

7.
Two different stent configurations (i.e. the well known Palmaz–Schatz (PS) and a new stent configuration) are mechanically investigated. A finite element model was used to study the two geometries under combining loads and a computational fluid dynamic model based on fluid structure interaction was developed investigating the plaque and the artery wall reactions in a stented arterial segment. These models determine the stress and displacement fields of the two stents under internal pressure conditions. Results suggested that stent designs cause alterations in vascular anatomy that adversely affect arterial stress distributions within the wall, which have impact in the vessel responses such as the restenosis. The hemodynamic analysis shows the use of new stent geometry suggests better biofluid mechanical response such as the deformation and the progressive amount of plaque growth.  相似文献   

8.
BACKGROUND: It has been suggested that the severity of acute vascular injury immediately after percutaneous transluminal coronary angioplasty (PTCA) or stent implantation correlates with the extent of neointimal hyperplasia and restenosis. However, the influence of prolonged or chronic vessel injury on the pathogenesis of restenosis is unclear. METHODS: Rabbit iliac arteries were balloon dilated for a short (1 min) or prolonged (10 min) period of time, or were chronically dilated and received a Palmaz-Schatz stent (balloon inflation for 1 min). All arteries were overexpanded to a balloon:artery ratio of 1.2:1 as determined by angiography. The arteries were removed 30 min and 4 weeks after the angioplasty procedures. The sites of injury were evaluated by gross histology and transmission electron microscopy (TEM). Cell death of medial smooth muscle cells (SMCs) was specified by TEM images 30 min after the procedures. Computer-assisted quantification of the neointimal cross-sectional areas was performed after 4 weeks using a light microscope connected to a digital image analyser. RESULTS: The results show that prolonged balloon dilatation and stent implantation increased necrotic SMC death compared with balloon dilatation for 1 min. After 30 min, increased staining of SMC nuclei, enlarged intercellular spaces and changes in SMC shape in the media indicated cell death induced by prolonged balloon dilatation or chronic stent injury. Stent implantation markedly augmented vessel damage by persistent compression of the media, compared with a balloon dilatation for 1 or 10 min. Both prolonged balloon dilatation and stent implantation increased neointimal hyperplasia at 4 weeks compared with balloon dilatation for 1 min (0.6 3 0.2 and 1.0 3 0.2 mm(2) versus 0.2 3 0.1 mm(2), P < 0.001 versus dilatation for 1 min). CONCLUSION: Prolonged or chronic vascular expansion due to long balloon-inflation periods or the implantation of stents increases medial SMC death, which subsequently stimulates neointimal growth in this restenosis model. Chronic vascular injury may be an important stimulus for restenosis after angioplasty procedures.  相似文献   

9.
Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.  相似文献   

10.
To reduce in-stent restenosis rates, we developed a novel drug-eluting covered stent with a microporous elastometric covered film, in which its luminal surface was flat and immobilized with heparin for anticoagulation and its outer surface immobilized with FK506 to prevent neointimal hyperplasia. One month after implantation into the bilateral common carotid arteries, all stented arteries were patent and the luminal surfaces were fully covered with a confluent of endothelial cells irrespective of the drug immobilization. In the control group, which consisted of covered stents without drug immobilization, intensive inflammatory cells adjacent to the stents and neointimal hyperplasia, indicating vascular injury, were observed. In contrast, in the developed drug-eluting stents, only a few inflammatory cells around the stent strut and covered film were observed, and there was no significant neointimal thickening.  相似文献   

11.
Atherton MA  Tesch K  Collins MW 《Biorheology》2002,39(3-4):501-506
Patient-to-patient variations in artery geometry may determine their susceptibility to stenosis formation. These geometrical variations can be linked to variations in flow characteristics such as wall shear stress through stents, which increases the risk of restenosis. This paper considers computer models of stents in non-symmetric flows and their effects on flow characteristics at the wall. This is a fresh approach from the point of view of identifying a stent design whose performance is insensitive to asymmetric flow. Measures of dissipated energy and power are introduced in order to discriminate between competing designs of stents.  相似文献   

12.
The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that stent geometry may cause local alterations in wall shear stress (WSS) that have been associated with neointimal hyperplasia and subsequent restenosis. However, previous CFD studies have ignored histological evidence of vascular straightening between circumferential stent struts. We tested the hypothesis that consideration of stent-induced vascular deformation may more accurately predict alterations in indexes of WSS that may subsequently account for histological findings after stenting. We further tested the hypothesis that the severity of these alterations in WSS varies with the degree of vascular deformation after implantation. Steady-state and time-dependent simulations of three-dimensional CFD arteries based on canine coronary artery measurements of diameter and blood flow were conducted, and WSS and WSS gradients were calculated. Circumferential straightening introduced areas of high WSS between stent struts that were absent in stented vessels of circular cross section. The area of vessel exposed to low WSS was dependent on the degree of circumferential vascular deformation and axial location within the stent. Stents with four vs. eight struts increased the intrastrut area of low WSS in vessels, regardless of cross-sectional geometry. Elevated WSS gradients were also observed between struts in vessels with polygonal cross sections. The results obtained using three-dimensional CFD models suggest that changes in vascular geometry after stent implantation are important determinants of WSS distributions that may be associated with subsequent neointimal hyperplasia.  相似文献   

13.
Clinical trials have reported different restenosis rates for various stent designs. It is speculated that stent-induced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis. This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface. As a mesh stent is deployed into a latex vessel with a random contrasting pattern sprayed or drawn on its outer surface, the surface strain is recorded at every instant of the deformation. The calculated strain distributions can then be used to understand the local lesion response, validate the computational models, and formulate hypotheses for further in vivo study.  相似文献   

14.
Coronary stent design affects the spatial distribution of wall shear stress (WSS), which can influence the progression of endothelialization, neointimal hyperplasia, and restenosis. Previous computational fluid dynamics (CFD) studies have only examined a small number of possible geometries to identify stent designs that reduce alterations in near-wall hemodynamics. Based on a previously described framework for optimizing cardiovascular geometries, we developed a methodology that couples CFD and three-dimensional shape-optimization for use in stent design. The optimization procedure was fully-automated, such that solid model construction, anisotropic mesh generation, CFD simulation, and WSS quantification did not require user intervention. We applied the method to determine the optimal number of circumferentially repeating stent cells (N(C)) for slotted-tube stents with various diameters and intrastrut areas. Optimal stent designs were defined as those minimizing the area of low intrastrut time-averaged WSS. Interestingly, we determined that the optimal value of N(C) was dependent on the intrastrut angle with respect to the primary flow direction. Further investigation indicated that stent designs with an intrastrut angle of approximately 40 deg minimized the area of low time-averaged WSS regardless of vessel size or intrastrut area. Future application of this optimization method to commercially available stent designs may lead to stents with superior hemodynamic performance and the potential for improved clinical outcomes.  相似文献   

15.
Polyvinyl alcohol (PVA) cryogel covered stents may reduce complications from thrombosis and restenosis by decreasing tissue prolapse. Finite element analysis was employed to evaluate the effects of PVA cryogel layers of varying thickness on tissue prolapse and artery wall stress for two common stent geometries and two vessel diameters. Additionally, several PVA cryogel covered stents were fabricated and imaged with an environmental scanning electron microscope. Finite element results showed that covered stents reduced tissue prolapse up to 13% and artery wall stress up to 29% with the size of the reduction depending on the stent geometry, vessel diameter, and PVA cryogel layer thickness. Environmental scanning electron microscope images of expanded covered stents showed the PVA cryogel to completely cover the area between struts without gaps or tears. Overall, this work provides both computational and experimental evidence for the use of PVA cryogels in covered stents.  相似文献   

16.
Coronary artery stenosis is commonly treated by stent placement via percutaneous intervention, at times requiring multiple stents that may overlap. Stent overlap is associated with increased risk of adverse clinical outcome. While changes in local blood flow are suspected to play a role therein, hemodynamics in arteries with overlapping stents remain poorly understood. In this study we analyzed six cases of partially overlapping stents, placed ex vivo in porcine left coronary arteries and compared them to five cases with two non-overlapping stents. The stented vessel geometries were obtained by micro-computed tomography of corrosion casts. Flow and shear stress distribution were calculated using computational fluid dynamics. We observed a significant increase in the relative area exposed to low wall shear stress (WSS<0.5 Pa) in the overlapping stent segments compared both to areas without overlap in the same samples, as well as to non-overlapping stents. We further observed that the configuration of the overlapping stent struts relative to each other influenced the size of the low WSS area: positioning of the struts in the same axial location led to larger areas of low WSS compared to alternating struts. Our results indicate that the overlap geometry is by itself sufficient to cause unfavorable flow conditions that may worsen clinical outcome. While stent overlap cannot always be avoided, improved deployment strategies or stent designs could reduce the low WSS burden.  相似文献   

17.
18.

Development and application of advanced mechanical models of soft tissues and their growth represent one of the main directions in modern mechanics of solids. Such models are increasingly used to deal with complex biomedical problems. Prediction of in-stent restenosis for patients treated with coronary stents remains a highly challenging task. Using a finite element method, this paper presents a mechanistic approach to evaluate the development of in-stent restenosis in an artery following stent implantation. Hyperelastic models with damage, verified with experimental results, are used to describe the level of tissue damage in arterial layers and plaque caused by such intervention. A tissue-growth model, associated with vessel damage, is adopted to describe the growth behaviour of a media layer after stent implantation. Narrowing of lumen diameter with time is used to quantify the development of in-stent restenosis in the vessel after stenting. It is demonstrated that stent designs and materials strongly affect the stenting-induced damage in the media layer and the subsequent development of in-stent restenosis. The larger the artery expansion achieved during balloon inflation, the higher the damage introduced to the media layer, leading to an increased level of in-stent restenosis. In addition, the development of in-stent restenosis is directly correlated with the artery expansion during the stent deployment. The correlation is further used to predict the effect of a complex clinical procedure, such as stent overlapping, on the level of in-stent restenosis developed after percutaneous coronary intervention.

  相似文献   

19.
A stent is a device designed to restore flow through constricted arteries. These tubular scaffold devices are delivered to the afflicted region and deployed using minimally invasive techniques. Stents must have sufficient radial strength to prop the diseased artery open. The presence of a stent can subject the artery to abnormally high stresses that can trigger adverse biologic responses culminating in restenosis. The primary aim of this investigation was to investigate the effects of varying stent "design parameters" on the stress field induced in the normal artery wall and the radial displacement achieved by the stent. The generic stent models were designed to represent a sample of the attributes incorporated in present commercially available stents. Each stent was deployed in a homogeneous, nonlinear hyperelastic artery model and evaluated using commercially available finite element analysis software. Of the designs investigated herein, those employing large axial strut spacing, blunted corners, and higher amplitudes in the ring segments induced high circumferential stresses over smaller areas of the artery's inner surface than all other configurations. Axial strut spacing was the dominant parameter in this study, i.e., all designs employing a small stent strut spacing induced higher stresses over larger areas than designs employing the large strut spacing. Increasing either radius of curvature or strut amplitude generally resulted in smaller areas exposed to high stresses. At larger strut spacing, sensitivity to radius of curvature was increased in comparison to the small strut spacing. With the larger strut spacing designs, the effects of varying amplitude could be offset by varying the radius of curvature and vice versa. The range of minimum radial displacements from the unstented diastolic radius observed among all designs was less than 90 microm. Evidence presented herein suggests that stent designs incorporating large axial strut spacing, blunted corners at bends, and higher amplitudes exposed smaller regions of the artery to high stresses, while maintaining a radial displacement that should be sufficient to restore adequate flow.  相似文献   

20.
Following the deployment of a coronary stent and disruption of an atheromatous plaque, the deformation of the arterial wall and the presence of the stent struts create a new fluid dynamic field, which can cause an abnormal biological response. In this study 3D computational models were used to analyze the fluid dynamic disturbances induced by the placement of a stent inside a coronary artery. Stents models were first expanded against a simplified arterial plaque, with a solid mechanics analysis, and then subjected to a fluid flow simulation under pulsatile physiological conditions. Spatial and temporal distribution of arterial wall shear stress (WSS) was investigated after the expansion of stents of different designs and different strut thicknesses. Common oscillatory WSS behavior was detected in all stent models. Comparing stent and vessel wall surfaces, maximum WSS values (in the order of 1Pa) were located on the stent surface area. WSS spatial distribution on the vascular wall surface showed decreasing values from the center of the vessel wall portion delimited by the stent struts to the wall regions close to the struts. The hemodynamic effects induced by two different thickness values for the same stent design were investigated, too, and a reduced extension of low WSS region (<0.5Pa) was observed for the model with a thicker strut.  相似文献   