共查询到20条相似文献,搜索用时 0 毫秒
1.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,672(2):277-281
A selective and sensitive method for the determination of lipoic acid in human plasma samples has been developed. After enzymatic hydrolysis of the sample, the liberated lipoic acid was extracted by a solid-phase cartridge and measured by HPLC using electrochemical detection. The detection limit was 1 ng/ml lipoic acid in plasma. The calibration curve was non-linear in the range 0.01–50 μg/ml but could be described by a power function. The average extraction recoveries were 82.5 and 85.1% at the 25 and 2500 ng/ml levels, respectively. Coefficients of variation for both within-day and day-to-day analysis were between 2.1 and 9.4%. The assay method is sensitive, reproducible and suitable for disposition studies of lipoic acid in humans. 相似文献
2.
Anders Helander 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,579(2)
A high-performance liquid chromatographic method for the routine determination of elevated urinary levels of the serotonin metabolite 5-hydroxytryptophol (5-HTOL) is described. Urine samples were treated with β-glucuronidase, and 5-HTOL was isolated by solid-phase extraction on a small Sephadex G-10 column prior to injection onto an isocratically eluted C18 reversed-phase column. Detection of 5-HTOL was performed electrochemically at +0.60 V vs. Ag/AgCl. The limit of detection was ca. 0.05 μM, and the intra-assay coefficients of variation were below 6% with urine samples containing 0.2 and 2.1 μM 5-HTOL and a standard solution of 2.0 μM (n = 5). The recovery of 5-HTOL after the sample clean-up procedure was close to 100%. A good correlation (r2 = 0.97; n = 12) was obtained between the present method and a sensitive and specific gas chromatographic—mass spectrometric method. The total (free plus conjugated) 5-HTOL levels in urine were normally below 0.2 μM, but after an acute dose of alcohol they increased to 0.5–15 μM. 相似文献
3.
4.
Ram N. Gupta 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,582(1-2)
We describe a simple method for extracting homovanillic acid (HVA) from plasma. An aliquot of 0.5 ml of the internal standard solution (3-hydroxy-4-methoxycinnamic acid in 0.2 mol/l phosphoric acid) and 0.5 ml of the sample are applied to a 1-ml Bond Elut C18 column prewashed with methanol and 0.2 mol/l phosphoric acid. The sample is drawn through the column at low speed. The column is washed with water and eluted with dichloromethane. The eluate is evaporated under vacuum at ambient temperature and the residue reconstituted with 250 μl of the mobile phase. A 10-μl aliquot of the resulting solution is injected onto a 150 mm × 4.6 mm I.D. column packed with 5-μm octadecylsilyl silica particles (Beckman). Peaks are detected coulometrically in the screening-oxidation mode with E1 = +0.25 V and E2 = +0.38 V. In the resulting chromatogram, HVA and the internal standard give sharp peaks and are well separated from solvent and other endogenous electroactive acids. The extraction recovery is 90–95% which allows the determination of 0.5 μg/l analyte. 相似文献
5.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1998,718(1):129-134
An alternative HPLC method for the quantification of the depolarizing neuromuscular blocking agent succinylcholine in human plasma is described. Drug spiked plasma and patient plasma samples were extracted using a C1 solid-phase cartridge. Succinylcholine was separated on a Cyano column and quantitated using electrochemical detection at a potential of 450 mV and 750 mV. Mobile phase consisted of a mixture of phosphoric acid–acetonitrile–methanol (45:35:25) adjusted to an apparent pH of 5. Standard curves for the quantitation were linear in the range of 250–8000 ng/ml. Between-day and within-day relative standard deviations were 5.1% and 1.7%, respectively. Mean drug recovery and accuracy was 68% and 104%, respectively. 相似文献
6.
Toshiyuki Takayasu Ikuhiro Kakubari Akemi Fukamachi Eiichi Mafune Norio Takasugi Kozo Takayama Tsuneji Nagai 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,679(1-2)
We report a sensitive new method for the determination of timiperone in rat plasma by using high-performance liquid chromatography with electrochemical detection. The method involves extraction of plasma samples with heptane-isoamyl alcohol at pH>8, followed by back-extraction into dilute acetic acid. Separation was accomplished by reversed-phase high-performance liquid chromatography on an ODS column with the mobile phase consisting of 0.1 M phosphate buffer (pH 3.5)-acetonitrile-methanol (65:20:15, v/v). Recovery was greater than 80%. Calibration curve was linear over the concentration range 0.5–50.0 ng/ml. The limit of quantitation of timiperone was 0.5 ng/ml plasma. 相似文献
7.
M. A. Raggi C. Sabbioni G. Casamenti G. Gerra N. Calonghi L. Masotti 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,730(2):3854-211
In the present study, assays were improved for the determination of catecholamines in human plasma. High-performance liquid chromatography with electrochemical detection was employed for quantitative analysis. The influence of various parameters on chromatographic performance, such as the composition and the pH of the mobile phase, and the detection potential, was investigated. An accurate solid-phase extraction procedure, after catecholamine complexation with diphenylborate, was developed. The efficiency yield for all catecholamines was in the range 92–98%. Relative standard deviation values for repeatability and for intermediate precision were less than 2% and 3%, respectively, for all three analytes. 相似文献
8.
Pineal and plasma melatonin as determined by high-performance liquid chromatography with electrochemical detection. 总被引:6,自引:0,他引:6
A rapid and sensitive method for the routine quantitative determination of melatonin in pineal and plasma is described. The assay used reversed-phase high-performance liquid chromatography (RP-HPLC) separation combined with either amperometric (system A) or coulometric (system B) detection. The method gave satisfactory reproducibility and accuracy, and detection limits for melatonin were as low as 8.5 pg (system A) and 1 pg (system B). This high sensitivity, together with the short analysis time (less than 10 min), and the simplicity of sample procedure make the present RP-HPLC method suitable for a wide range of studies concerning melatonin measurements. Melatonin values obtained in this study from both rat pineal and human plasma agree with those reported previously, and clearly determined a circadian pattern. 相似文献
9.
Richard D. Todd Sheila M. Muldoon Robert L. Watson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1982,232(1):101-110
Two methods for the extraction of morphine from cerebrospinal fluid or plasma with quantitation by high-performance liquid chromatography with electrochemical detection were compared for accuracy, precision and ease of preparation. One procedure was a standard extraction procedure and the other utilized a commercially available liquid—liquid extraction column. Both methods produced linear calibration curves over the concentration range of 1–200 ng/ml with coefficients of correlation of 0.999. Since the electrochemical detector is capable of detecting 20 pg of morphine, biological samples as small as 0.1 to 0.4 ml can be quantified with an average relative precision of 4.1 ± 3.9% over the concentration range 1–200 ng/ml. The potential clinical importance of the assay is demonstrated using a time course distribution study of morphine in the cerebrospinal fluid and plasma of a Rhesus monkey. 相似文献
10.
11.
A method for the routine quantitative determination of the major serotonin metabolite 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is described. 5-HIAA was analyzed without prior sample cleanup, using an automated high-performance liquid chromatography system with isocratic elution and electrochemical detection (+0.60 V versus a Ag/AgCl reference electrode). The urine samples were mixed with a solution of the internal standard (5-hydroxyindole-3-propionic acid) and centrifuged. The supernatant was transferred to sealed glass vials, and a 2-microliters aliquot was injected directly onto a C18 reversed-phase analytical column, using an automatic sample injector. Samples of urine could be stored for several months at -80 or at +7 degrees C for 2 days without loss of 5-HIAA. However, a gradual decline with time occurred in crude samples stored at room temperature or above, as well as in urine samples diluted with the mobile phase. The detector response was linear in the range of 0-65 mumol/l 5-HIAA, and the intra- and interassay coefficients of variation were about 5 and 7%, respectively (n = 10). 相似文献
12.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,757(1):135-141
This paper describes a high-performance liquid chromatographic method with electrochemical detection for the determination of etoposide levels in plasma, total and non-protein bound concentration, and in leukemic cells. The precision for between-runs (n=6) was 7.0, 4.9, and 9.5%, the accuracy was 3.7, 7.1 and 6.3%, and within-runs precision (n=6) was 3.9, 2.9 and 5.1% for total plasma, non-protein bound plasma fraction and leukemic cells, respectively. The correlation coefficients (R2) were 1.00 for all calibration curves. These assays have been applied to analyze samples from one patient with acute myelogenous leukemia during 24 h after i.v. infusion of etoposide (100 mg/m2). 相似文献
13.
Michael P. Turberg John M. Rodewald Mark R. Coleman 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,675(2):279
A high-performance liquid chromatographic (HPLC) method is described for the determination of ractopamine (LY031537) in monkey plasma and swine serum. Plasma or serum (0.5 ml) was diluted with phosphate buffer pH 7.0. Ractopamine was isolated from the plasma matrix using ion exchange on a polymeric carboxylic acid solid-phase extraction cartridge followed by partitioning with ethyl acetate. An isocratic HPLC method using electrochemical detection at +700 mV was used to separate and measure ractopamine in the purified extract in 6.5 min of run time. Standard area response was linear with respect to concentration of ractopamine over the range of 0.5 to 40 ng/ml. Validation data were collected using rhesus monkey plasma and swine serum. The method precision and accuracy were evaluated in the range 1.0 to 20 ng/ml using fortified samples of monkey plasma. The method limit of quantitation was estimated at 2 ng/ml as determined in monkey plasma. 相似文献
14.
Lina Long Douglas R. McCabe M. Eileen Dolan 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,731(2):128
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine. 相似文献
15.
Machida M Watanabe M Takechi S Kakinoki S Nomura A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,798(2):187-191
Carvedilol is a beta/alpha1-adrenoceptor blocker. A sensitive method for measuring plasma levels of carvedilol in human administrated low doses is needed since its plasma concentration is low. We measured carvedilol and carvedilol M21-aglycon using high-performance liquid chromatography (HPLC) with electrochemical detection. The amperometric detector was operated at 930 mV versus Ag/AgCl. Mean coefficients of variation (n = 5) for carvedilol and M21-aglycon were 4.0 and 7.7% (intra) and 6.1 and 6.7% (inter), respectively. The lower limit of quantification for each analyte was 0.10 ng/ml (signal-to-noise ratio = 3). This lower limit of quantification for carvedilol was sufficient for clinical use. 相似文献
16.
Inoue K Namiki T Iwasaki Y Yoshimura Y Nakazawa H 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,785(1):57-63
The aim of the present study is to establish a highly sensitive method for the determination of uric acid (UA) in human saliva. The monitoring of UA levels in less invasive biological samples such as saliva is suggested for the diagnosis and therapy of gout, hyperuricemia, and the Lesch-Nyhan syndrome, and for detecting such conditions as alcohol dependence, obesity, diabetes, high cholesterol, high blood pressure, kidney disease, and heart disease. Reversed-phase high-performance liquid chromatography with electrochemical detection (HPLC-ED) was employed for the determination of UA obtained by solid-phase extraction from saliva. To quantify UA, we compared the ED efficiencies of an amperometric ED (Ampero-ED) with a single electrode and a coulometric ED (Coulo-ED) with a multiple electrode array. The results showed that the detection limits (S/N=3) were 3 nM for Ampero-ED and 6 nM for Coulo-ED, and the linearity of the calibration curves of 60-6000 nM had correlation coefficients exceeding 0.999. In addition, the total analytical time was 10 min. In the sample preparation of UA in saliva, an Oasis MAX solid-phase cartridge was used. The recoveries of UA spiked at 0.6 and 3 microM in saliva were above 95% with a relative standard deviation (RSD) of less than 15%. Therefore, the present method may be used in the routine and diagnostic determination of UA in human saliva. 相似文献
17.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,694(1):185-191
A sensitive method has been developed for the determination of hydroxyurea in plasma and peritoneal fluid using reversed-phase high-performance liquid chromatography (HPLC) with electrochemical detection. Plasma or peritoneal fluid samples were treated with acetonitrile to precipitate proteins then injected to the HPLC. A C18 analytical column was used to separate hydroxyurea from interfering substances in the biological matrix. The mobile phase, consisting of 0.2 M sodium perchlorate–methanol (95:5, v/v) adjusted to pH 5.0, was delivered isocratically at a flow-rate of 1 ml/min and hydroxyurea was detected using a glassy-carbon electrode operating at an applied potential of +800 mV. Hydroxyurea eluted with a retention time of 3 min. The cycle time for analysis is short and the assay precision is acceptable (C.V. plasma=1.4–3.9%, C.V. peritoneal fluid=2.1–9.7%). The method has been validated and is linear from 25 to 400 ng/ml in plasma and 5 to 30 ng/ml in peritoneal fluid. The method has been shown to be applicable for pharmacokinetic studies. 相似文献
18.
Cristine A Costa Gilmar C.Trivelato Marilene Demasi Etelvino J.H Bechara 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,695(2):88
A simple and sensitive method for determining 5-aminolevulinic acid (ALA) in biological samples is described. ALA is derivatized with o-phthaldehyde to give a compound with favorable properties for high-performance liquid chromatography with electrochemical detection. The method does not require extensive pretreatment of the samples and its detection limit is in the range of 1 pmol/20 μl injection. This method was applied to the determination of plasma ALA from normal and lead-exposed subjects, where 0.26±0.08 μM (n=30) and 2.6±0.75 μM (n=30), respectively were found. We also determined ALA in rat tissues, namely liver and brain, and the uptake of ALA by cultured fibroblasts and hepatocytes to illustrate the diversified applicability of the method. 相似文献
19.
Determination of plasma homocysteine by high-performance liquid chromatography with fluorescence detection 总被引:1,自引:0,他引:1
Severe homocystinemia is frequently associated with vascular disease while the pathological consequences of moderate or slightly elevated plasma homocysteine are unknown. Cobalamin and folate deficiencies may result in an elevation of plasma homocysteine. A sensitive and reproducible assay for total plasma homocysteine has been developed. The essential steps in the assay include (i) conversion of homocysteine disulfides to free homocysteine with borohydride reduction; (ii) conjugation of homocysteine with monobromobimane; (iii) separation of homocysteine-bimane from other plasma thiol-bimane adducts by reverse-phase high-performance liquid chromatography; and (iv) detection and quantitation of homocysteine-bimane by fluorometry. The method has a sensitivity of 4.4 pmol of homocysteine and is highly reproducible (intra- and interassay coefficients of variation = 4.97 and 4.53%, respectively). The mean concentration of total plasma homocysteine in nonfasting adult males (n = 12) and females (n = 12) was 15.8 (range, 7.0-23.7) and 16.5 nmol/ml (range, 8.6-20.7), respectively. Markedly elevated levels of homocysteine were found in patients with cobalamin and folate deficiency. Total plasma homocysteine represents approximately 4% of borohydride-generated thiol reactivity in the plasma of normal individuals. 相似文献
20.
Corrado Sarzanini Edoardo Mentasti Marco Vincenti Mario Nerva Flavio Gaido 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1993,620(2):268-272
An HPLC procedure has been developed for tocopherol determination with coulometric detection in human serum samples. Eluent optimization and foreign peak identification (bilirubin) by mass spectrometry are described. An extraction procedure gave yields around 98% with 1.3% coefficient of variation, and the calibration ranged from 0.1 to 200 mg/l with a correlation coefficient of 0.999. The detection limit achieved for vitamin E was 60 pg (3 ng/ml). 相似文献