 共查询到20条相似文献,搜索用时 62 毫秒
1.
PurposeIntraoperative radiation therapy (IORT) using electron beam is commonly done by mobile dedicated linacs that have a variable range of electron energies. This paper focuses on the evaluation of the EBT2 film response in the green and red colour channels for IORT quality assurance (QA).MethodsThe calibration of the EBT2 films was done in two ranges; 0–8 Gy for machine QA by red channel and 8–24 Gy for patient-specific QA by green channel analysis. Irradiation of calibration films and relative dosimetries were performed in a water phantom. To evaluate the accuracy of the film response in relative dosimetry, gamma analysis was used to compare the results of the Monte Carlo simulation and ionometric dosimetry. Ten patients with early stage breast cancer were selected for in-vivo dosimetry using the green channel of the EBT2 film.ResultsThe calibration curves were obtained by linear fitting of the green channel and a third-order polynomial function in the red channel (R2 = 0.99). The total dose uncertainty was up to 4.2% and 4.7% for the red and green channels, respectively. There was a good agreement between the relative dosimetries of films by the red channel, Monte Carlo simulations and ionometric values. The mean dose difference of the in-vivo dosimetry by green channel of this film and the expected values was about 1.98% ± 0.75.ConclusionThe results of this study showed that EBT2 film can be considered as an appropriate tool for machine and patient-specific QA in IORT.  相似文献   

2.
PurposeThe entrance beam fluence of therapeutic proton scanning beams can be monitored using a gantry-attachable plastic scintillating plate (GAPSP). This study evaluated the clinical application of the GAPSP using a method that measures intensity modulated proton therapy (IMPT) beams for patient treatment.MethodsIMPT beams for the treatment of nine patients, at sites that included the spine, head and neck, pelvis, and lung, were measured using the GAPSP, composed of an EJ-212 plastic scintillator and a CMOS camera. All energy layers distinguished by the GAPSP were accumulated to determine the dose distribution of the treatment field. The evaluated fields were compared with reference dose maps verified by quality assurance.ResultsComparison of dose distributions of evaluation treatment fields with reference dose distributions showed that the 3%/1 mm average gamma passing rate was 96.4%, independent of the treatment site, energy range and field size. When dose distributions were evaluated using the same criteria for each energy layer, the average gamma passing rate was 91.7%.ConclusionsThe GAPSP is a suitable, low-cost method for monitoring pencil beam scanning proton therapy, especially for non-spot scanning or additional collimation. The GAPSP can also estimate the treatment beam by the energy layer, a feature not common to other proton dosimetry tools.  相似文献   

3.
PurposeThe Council Directive 2013/58/EURATOM entered into force in 2014, and its transposition into national legislations became applicable in 2018. The Council Directive 2013/58/EURATOM strengthened the importance of clinical audits, and stated that Member States should ensure dosimetry audit compliance in accordance with national procedures. Therefore, the purpose of this work was to picture the status of the implementation of dosimetry audits in European countries. Methods: A questionnaire was designed to describe dosimetry audit standards in radiotherapy across European countries. The questionnaire was sent to 33 EFOMP National Member Organizations (NMO). Results: Nineteen NMOs responded to the survey (14 EU members). For 58% of the participating countries national regulations required dosimetry audits in radiotherapy departments. In 37% of the participating countries there were implemented regulations for independent/secondary dose verification, and in 21% of the participating countries similar procedures for dose verification were already implemented although not regulated by law. In 42% of the participating countries there were implemented mechanisms to review updates and advances in the field of radiotherapy.ConclusionsThe transposition and further implementation of the Council Directive 2013/59/EURATOM was scarce, leading to heterogeneities in national policies about dosimetry audits.  相似文献   

4.
PurposeDynamic delivery of intensity modulated beams (dIMRT) requires not only accurate verification of leaf positioning but also a control on the speed of motion. The latter is a parameter that has a major impact on the dose delivered to the patient. Time consumed in quality assurance (QA) procedures is an issue of relevance in any radiotherapy department. Electronic portal imaging dosimetry (EPID) can be very efficient for routine tests. The purpose of this work is to investigate the ability of our EPID for detecting small errors in leaf positioning, and to present our daily QA procedures for dIMRT based on EPID.Methods and materialsA Varian 2100 CD Clinac equipped with an 80 leaf Millennium MLC and with amorphous silicon based EPID (aS500, Varian) is used. The daily QA program consists in performing: Stability check of the EPID signal, Garden fence test, Sweeping slit test, and Leaf speed test.Results and discussionThe EPID system exhibits good long term reproducibility. The mean portal dose at the centre of a 10 × 10 cm2 static field was 1.002 ± 0.004 (range 1.013–0.995) for the period evaluated of 47 weeks. Garden fence test shows that leaf position errors of up to 0.2 mm can be detected. With the Sweeping slit test we are able to detect small deviations on the gap width and errors of individual leaves of 0.5 and 0.2 mm. With the Leaf speed test problems due to motor fatigue or friction between leaves can be detected.ConclusionsThis set of tests takes no longer than 5 min in the linac treatment room. With EPID dosimetry, a consistent daily QA program can be applied, giving complete information about positioning/speed MLC.  相似文献   

5.
Intensity modulated radiotherapy (IMRT) is one of the most modern radiation therapy treatment techniques. Although IMRT can deliver high and complex conformational doses to the tumor volume, its implementation requires rigorous quality assurance (QA) procedures that include a dosimetric pre-treatment verification of individual patient planning. This verification usually involves measuring a small volume of absolute dose with an ionization chamber and checking bi-dimensional fluency with an array of detectors. The planning technique has tri-dimensional characteristics, but no tridimensional dosimetry has been established in the clinical routine. One strategy to perform three-dimensional dosimetry is to use polymeric gels associated with magnetic resonance imaging to evaluate dose distribution. Here, we have compared the results of conventional QA procedures involving one- and two-dimensional dosimetry to the results of three-dimensional dosimetry conducted with MAGIC-f gel in 10 cases of prostate cancer IMRT planning. More specifically, we used the gamma index (3%/3 mm) to compare the results of three-dimensional dosimetry to the expected dose distributions obtained with the treatment planning system. Except for one IMRT treatment plan, the gel dosimetry results agreed with the conventional quality control and provided an overview of dose distribution in the target volume.  相似文献   

6.
ObjectiveThis paper investigated the cost-effectiveness of a computer-assisted Clinical Decision Support System (CDSS) in the identification of maternal complications in Ghana.MethodsA cost-effectiveness analysis was performed in a before- and after-intervention study. Analysis was conducted from the provider’s perspective. The intervention area was the Kassena- Nankana district where computer-assisted CDSS was used by midwives in maternal care in six selected health centres. Six selected health centers in the Builsa district served as the non-intervention group, where the normal Ghana Health Service activities were being carried out.ResultsComputer-assisted CDSS increased the detection of pregnancy complications during antenatal care (ANC) in the intervention health centres (before-intervention= 9 /1,000 ANC attendance; after-intervention= 12/1,000 ANC attendance; P-value=0.010). In the intervention health centres, there was a decrease in the number of complications during labour by 1.1%, though the difference was not statistically significant (before-intervention =107/1,000 labour clients; after-intervention= 96/1,000 labour clients; P-value=0.305). Also, at the intervention health centres, the average cost per pregnancy complication detected during ANC (cost –effectiveness ratio) decreased from US$17,017.58 (before-intervention) to US$15,207.5 (after-intervention). Incremental cost –effectiveness ratio (ICER) was estimated at US$1,142. Considering only additional costs (cost of computer-assisted CDSS), cost per pregnancy complication detected was US$285.ConclusionsComputer –assisted CDSS has the potential to identify complications during pregnancy and marginal reduction in labour complications. Implementing computer-assisted CDSS is more costly but more effective in the detection of pregnancy complications compared to routine maternal care, hence making the decision to implement CDSS very complex. Policy makers should however be guided by whether the additional benefit is worth the additional cost.  相似文献   

7.
8.
PurposeTriple channel algorithm and specific procedures make more reliable radiochromic dosimetry for treatment planning verification and quality assurance in radiation therapy. A tool to obtain radiochromic dose distributions and compare them with the ones resulting from a treatment planning system was developed and applied.MethodsThe tool was developed as Microsoft Excel macro; it builds dose calibration curves against net optical density of Gafchromic EBT3 film, produces axial, coronal and sagittal dose maps and allows to evaluate them against dose distributions calculated by the Varian treatment planning system Eclipse using gamma index and gamma angle.ResultsThe net optical density standard errors of estimate of calibration curves at 6 MV Varian DBX600 linac energy were 0.2%, 0.4% and 0.2% for the red, green and blue channels. Tests of these curves by means of three independent eight dose points measurement series, at 15 MV and 6 MV Varian 2100C linac and at 6 MV DBX600 linac energies, showed less than 2% of dose errors for the red channel and less than 3% for the green channel in the range 100–450 cGy. The comparisons between dose distributions from Gafchromic EBT3 triple channel algorithm and the ones from Eclipse analytic anisotropic algorithm (AAA) showed values of gamma index 95th percentile between 0.6 and 1.0.ConclusionThe obtained results encourage the application of this tool in radiation therapy quality assurance.  相似文献   

9.
BackgroundWith full access to both helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT), we compared locally advanced non-small cell lung cancer (LA-NSCLC) treatment plans and verified the plans using patient-specific pretreatment quality assurance (PSQA).Materials and methodsFor each of the seventeen patients included in the study, two treatment plans (i.e. HT and VMAT) were created. Optimized plans were evaluated following the ICRU 83 criteria. Planned quality indexes and dosimetric parameters were compared. Lastly, all plans were subjected to PSQA assessment by determining the gamma passing rate (GPR).ResultsAll dosimetry results obtained from the planning target volume passed the ICRU 83 criteria. With regard to similar homogeneity indices, VMAT produced better conformity number values than HT (0.78 vs. 0.64), but differences in the values were insignificant. Furthermore, VMAT was associated with a significantly shorter mean treatment time (1.91 minutes vs. 6.66 minutes). For PSQA assessment, both techniques resulted in adequate GPR values (> 90% at the 3%/3 mm criteria).ConclusionBoth HT and VMAT techniques led to the generation of clinically satisfactory and reliable radiotherapy plans. However, the VMAT plan was associated with a non-significantly better degree of conformity and a significantly shorter treatment time. Thus, VMAT was determined to be a better choice for LA-NSCLC.  相似文献   

10.
PurposeFlattening filter free (FFF) beams are increasingly being considered for stereotactic radiotherapy (SRT). For the first time, the performance of a monolithic silicon array detector under 6 and 10 MV FFF beams was evaluated. The dosimeter, named “Octa” and designed by the Centre for Medical Radiation Physics (CMRP), was tested also under flattened beams for comparison.MethodsOutput factors (OFs), percentage depth-dose (PDD), dose profiles (DPs) and dose per pulse (DPP) dependence were investigated. Results were benchmarked against commercially available detectors for small field dosimetry.ResultsThe dosimeter was shown to be a ‘correction-free’ silicon array detector for OFs and PDD measurements for all the beam qualities investigated. Measured OFs were accurate within 3% and PDD values within 2% compared against the benchmarks. Cross-plane, in-plane and diagonal DPs were measured simultaneously with high spatial resolution (0.3 mm) and real time read-out. A DPP dependence (24% at 0.021 mGy/pulse relative to 0.278 mGy/pulse) was found and could be easily corrected for in the case of machine specific quality assurance applications.ConclusionsResults were consistent with those for monolithic silicon array detectors designed by the CMRP and previously characterized under flattened beams only, supporting the robustness of this technology for relative dosimetry for a wide range of beam qualities and dose per pulses. In contrast to its predecessors, the design of the Octa offers an exhaustive high-resolution 2D dose map characterization, making it a unique real-time radiation detector for small field dosimetry for field sizes up to 3 cm side.  相似文献   

11.
ObjectivesThe study performs a cost-effectiveness analysis of procedures for atrial septal defects occlusion, comparing conventional surgery to septal percutaneous implant.MethodsA model of analytical decision was structured with symmetric branches to estimate cost-effectiveness ratio between the procedures. The decision tree model was based on evidences gathered through meta-analysis of literature, and validated by a panel of specialists. The lower number of surgical procedures performed for atrial septal defects occlusion at each branch was considered as the effectiveness outcome. Direct medical costs and probabilities for each event were inserted in the model using data available from Brazilian public sector database system and information extracted from the literature review, using micro-costing technique. Sensitivity analysis included price variations of percutaneous implant.ResultsThe results obtained from the decision model demonstrated that the percutaneous implant was more cost effective in cost-effectiveness analysis at a cost of US$8,936.34 with a reduction in the probability of surgery occurrence in 93% of the cases. Probability of atrial septal communication occlusion and cost of the implant are the determinant factors of cost-effectiveness ratio.ConclusionsThe proposal of a decision model seeks to fill a void in the academic literature. The decision model proposed includes the outcomes that present major impact in relation to the overall costs of the procedure. The atrial septal defects occlusion using percutaneous implant reduces the physical and psychological distress to the patients in relation to the conventional surgery, which represent intangible costs in the context of economic evaluation.  相似文献   

12.
PurposeIn this work, the potential of an innovative “edgeless” silicon diode was evaluated as a response to the still unmet need of a reliable tool for plan dosimetry verification of very high dose, non-coplanar, patient-specific radiosurgery treatments. In order to prove the effectiveness of the proposed technology, we focused on radiosurgical treatments for functional disease like tremor or pain.MethodsThe edgeless diodes response has been validated with respect to clinical practice standard detectors by reproducing the reference dosimetry data adopted for the Treatment Planning System. In order to evaluate the potential for radiosurgery patient-specific treatment plan verification, the anthropomorphic phantom Alderson RANDO has been adopted along with three edgeless sensors, one placed in the centre of the Planning Target Volume, one superiorly and one inferiorly.ResultsThe reference dosimetry data obtained from the edgeless detectors are within 2.6% for output factor, off-axis ratio and well within 2% for tissue phantom ratio when compared to PTW 60,018 diode. The edgeless detectors measure a dose discrepancy of approximately 3.6% from the mean value calculated by the TPS. Larger discrepancies are obtained in very steep gradient dose regions when the sensors are placed outside the PTV.ConclusionsThe angular independent edgeless diode is proposed as an innovative dosimeter for patient quality assurance of brain functional disorders and other radiosurgery treatments. The comparison of the diode measurements with TPS calculations confirms that edgeless diodes are suitable candidates for patient-specific dosimetric verification in very high dose ranges delivered by non-isocentric stereotactic radiosurgery modalities.  相似文献   

13.
PurposeCurrent quality assurance of radiotherapy involving bony regions generally utilises homogeneous phantoms and dose calculations, ignoring the challenges of heterogeneities with dosimetry problems likely occurring around bone. Anthropomorphic phantoms with synthetic bony materials enable realistic end-to-end testing in clinical scenarios. This work reports on measurements and calculated corrections required to directly report dose in bony materials in the context of comprehensive end-to-end dosimetry audit measurements (63 plans, 6 planning systems).Materials and methodsRadiochromic film and microDiamond measurements were performed in an anthropomorphic spine phantom containing bone equivalent materials. Medium dependent correction factors, kmed, were established using 6 MV and 10 MV Linear Accelerator Monte Carlo simulations to account for the detectors being calibrated in water, but measuring in regions of bony material. Both cortical and trabecular bony material were investigated for verification of dose calculations in dose-to-medium (Dm,m) and dose-to-water (Dw,w) scenarios.ResultsFor Dm,m calculations, modelled correction factors for cortical and trabecular bone in film measurements, and for trabecular bone in microDiamond measurements were 0.875(±0.1%), 0.953(±0.3%) and 0.962(±0.4%), respectively. For Dw,w calculations, the corrections were 0.920(±0.1%), 0.982(±0.3%) and 0.993(±0.4%), respectively. In the audit, application of the correction factors improves the mean agreement between treatment plans and measured microDiamond dose from −2.4%(±3.9%) to 0.4%(±3.7%).ConclusionMonte Carlo simulations provide a method for correcting the dose measured in bony materials allowing more accurate comparison with treatment planning system doses. In verification measurements, algorithm specific correction factors should be applied to account for variations in bony material for calculations based on Dm,m and Dw,w.  相似文献   

14.
AimThis study focused on evaluating the sensitivity of integral quality monitoring (IQM®) system and MatriXX detectors. These two detectors are recommended for radiotherapy pre-treatment quality assurance (QA).BackgroundIQM is a large wedged-shaped ionisation chamber mounted to the linear accelerator (linac) head in practice. MatriXX consists of an array of ionisation chambers also attached to the linac head.Materials and methodsIn this study, the dosimetric performance and sensitivity of MatriXX and IQM detectors were evaluated using the following characteristics: reproducibility, linearity, error detection capability and three-dimensional conformal radiotherapy (3D-CRT) plans of the head and neck, thorax and pelvic regions.ResultsThis study indicates that the signal responses of the large ionisation chamber device (IQM) and the small pixel array of ionisation chambers device (MatriXX) are reproducible, linear and sensitive to MLC positional errors, backup jaw positional errors and dose errors. The local percentage differences for dose errors of 1%, 2%, and 3% were, respectively, within 0.35–8.23%, 0.78–16.21%, and 1.10–24.41% for the IQM device. While for the MatriXX detector, the ranges were between 0.24–3.19, 0.57–6.43 and 0.81–12.95, respectively. Since IQM is essentially a double wedge-shaped large ionisation chamber, its reproducibility and detection capability are competitive to that of MatriXX. In addition, the sensitivity of the two QA systems increases with an increase in escalation percentage, and the signal responses are patient plan specific.ConclusionsThe two detectors response signals have good correlations and they are accurate for pre-treatment QA. Statistically, (P < 0.05) there is a significant difference between the IQM and MatriXX response to dose errors.  相似文献   

15.
16.
PurposeThe aim of this study is to report results of measurements of dose to the skin in vivo with radiochromic EBT films in treatments with helical tomotherapy.Methods and materialsIn vivo measurements were performed by applying pieces of radiochromic films to the skin or to the inner side of thermoplastic mask before the treatment. The sites of treatment included scalp, brain, head and neck, cranio-spinal axis and lower limbs. Skin dosimetry was performed in a patient who experienced grade 3–4 acute side effects to the skin shortly after the first treatment sessions. For each patient we measured the setup errors using the daily MVCT acquired for image guidance of the treatment. EBT films were read with a flatbed Epson Expression scanner and images were processed with an in-house written routine.ResultsA total of 96 measurements of dose to the skin performed on 14 patients. The mean difference and standard error of the mean difference between measured and TPS-calculated dose was ?9.2% ± 2.6% for all treatments, ?6.6% ± 2.6% for head and neck treatments. These differences were statistically significant at the 0.05 significance level (t-Student test). Planned dose and dose range in the region of measurements were not correlated with dose discrepancy.ConclusionsRadiochromic EBT films are suitable detectors for surface dose measurements in tomotherapy treatments. Results show that TPS overestimates dose to the skin measured with EBT radiochromic films. In vivo skin measurements with EBT films are a useful tool for quality assurance of tomotherapy treatments, as the treatment planning system may not give accurate dose values at the surface.  相似文献   

17.
BackgroundFor the treatment of depressive disorders, the framework of collaborative care has been recommended, which showed improved outcomes in the primary care sector. Yet, an earlier literature review did not find sufficient evidence to draw robust conclusions on the cost-effectiveness of collaborative care.PurposeTo systematically review studies on the cost-effectiveness of collaborative care, compared with usual care for the treatment of patients with depressive disorders in primary care.MethodsA systematic literature search in major databases was conducted. Risk of bias was assessed using the Cochrane Collaboration’s tool. Methodological quality of the articles was assessed using the Consensus on Health Economic Criteria (CHEC) list. To ensure comparability across studies, cost data were inflated to the year 2012 using country-specific gross domestic product inflation rates, and were adjusted to international dollars using purchasing power parities (PPP).ResultsIn total, 19 cost-effectiveness analyses were reviewed. The included studies had sample sizes between n = 65 to n = 1,801, and time horizons between six to 24 months. Between 42% and 89% of the CHEC quality criteria were fulfilled, and in only one study no risk of bias was identified. A societal perspective was used by five studies. Incremental costs per depression-free day ranged from dominance to US$PPP 64.89, and incremental costs per QALY from dominance to US$PPP 874,562.ConclusionDespite our review improved the comparability of study results, cost-effectiveness of collaborative care compared with usual care for the treatment of patients with depressive disorders in primary care is ambiguous depending on willingness to pay. A still considerable uncertainty, due to inconsistent methodological quality and results among included studies, suggests further cost-effectiveness analyses using QALYs as effect measures and a time horizon of at least 1 year.  相似文献   

18.
摘要 目的:探讨愈创紫草油改善头颈部恶性肿瘤放疗患者所致放射性皮肤黏膜损伤的临床疗效,以期为头颈部恶性肿瘤放疗患者所致放射性皮肤黏膜损伤提供新的治疗方法。方法:选取安徽中医药大学附属六安医院2021年3月-2023年3月头颈部恶性肿瘤放疗患者100例作为研究对象,随机数字表随机分为观察组和对照组,各50例。两组均采用适形调强放射治疗,对照组给予常规放疗皮肤管理与宣教,观察组在对照组基础上给予涂抹愈创紫草油治疗。比较两组皮肤黏膜损伤程度、临床疗效、放疗完成率、皮损愈合时间,放疗2、4、6周时数字评分法(NRS)评分、Karnofsky功能状态(KPS)评分、皮肤病生活质量量表(DLQI)评分;放疗前、放疗6周时炎性细胞因子[白介素-6(IL-6)、降钙素原(PCT)、超敏C反应蛋白(hs-CRP)]水平及皮肤不良反应。结果:观察组皮肤黏膜损伤程度分级低于对照组(P<0.05);观察组总有效率94.00%较对照组80.00%高(P<0.05);放疗4、6周时观察组NRS评分、DLQI评分低于对照组,KPS评分高于对照组(P<0.05);两组放疗完成率均为100%,观察组皮损愈合时间较对照组短(P<0.05);放疗6周时观察组血清IL-6、PCT、hs-CRP水平低于对照组(P<0.05);两组患者均未出现过敏所致皮疹、红肿、瘙痒等皮肤不良反应。结论:愈创紫草油可有效减轻头颈部恶性肿瘤放疗所致放射性皮肤黏膜损伤,降低血清炎性细胞因子水平,促进患者皮损愈合,提高生活质量,疗效显著,且安全性高。  相似文献   

19.
It has been generally considered that improved methods of quality assurance would reduce the population dose from diagnostic radiology. This paper describes the development of a computerized method of automatically monitoring tube and generator parameters to perform on-line quality assurance, whilst undertaking various patient dosimetry measurements and calculations for each exposure. The method involves interfacing a microcomputer to a microprocessor controlled X-ray generator. Details of the various interfacing methods and modifications to the X-ray unit are given. The instrument enables quality assurance to be performed for every exposure by comparing tube and generator parameters against nominal settings. The software automatically warns the operator of any deviations from accepted limiting values. When a patient is examined, details of the examination and projection are entered into a database. The exposure area product and field size are monitored for each exposure. This data, together with information on tube potential and examination/projection is used to deduce patient entrance skin dose and energy imparted. Doses to individual organs are estimated using normalized organ dose data and a knowledge of tube potential and field size.  相似文献   

20.
PurposeRobotic radiosurgery demands comprehensive delivery quality assurance (DQA), but guidelines for commissioning of the DQA method is missing. We investigated the stability and sensitivity of our film-based DQA method with various test scenarios and routine patient plans. We also investigated the applicability of tight distance-to-agreement (DTA) Gamma-Index criteria.Methods and materialWe used radiochromic films with multichannel film dosimetry and re-calibration and our analysis was performed in four steps: 1) Film-to-plan registration, 2) Standard Gamma-Index criteria evaluation (local-pixel-dose-difference ≤2%, distance-to-agreement ≤2 mm, pass-rate ≥90%), 3) Dose distribution shift until maximum pass-rate (Maxγ) was found (shift acceptance <1 mm), and 4) Final evaluation with tight DTA criteria (≤1 mm). Test scenarios consisted of purposefully introduced phantom misalignments, dose miscalibrations, and undelivered MU. Initial method evaluation was done on 30 clinical plans.ResultsOur method showed similar sensitivity compared to the standard End-2-End-Test and incorporated an estimate of global system offsets in the analysis. The simulated errors (phantom shifts, global robot misalignment, undelivered MU) were detected by our method while standard Gamma-Index criteria often did not reveal these deviations. Dose miscalibration was not detected by film alone, hence simultaneous ion-chamber measurement for film calibration is strongly recommended. 83% of the clinical patient plans were within our tight DTA tolerances.ConclusionOur presented methods provide additional measurements and quality references for film-based DQA enabling more sensitive error detection. We provided various test scenarios for commissioning of robotic radiosurgery DQA and demonstrated the necessity to use tight DTA criteria.  相似文献   