首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The value of plain radiographs, digital subtraction arthrography and radionuclide arthrography was analysed in 23 cases of failed total knee arthroplasty. The preoperative diagnosis was compared with the intraoperative assessment. Sensitivity, specificity and the positive and negative predictive value for assessing a loose component were determined separately for the femoral and tibial components. At revision we found 13 loose femoral and 12 loose tibial implants. In eight cases both components were unstable. Plain radiography had a sensitivity of 77% for loosening of the femoral and 83% for the tibial component; digital subtraction arthrography 77% for the femoral and 8% for the tibial component and radionuclide arthrography 31% and 8%. The specificity for plain radiography was 90% for the femoral and 72% for the tibial implant. For subtraction arthrography it was 50% and 82% and for subtraction arthrography 70% and 82%. Radiography had the highest positive and negative predictive values for both components compared with the other two techniques. As a diagnostic tool to detect implant loosening, plain radiography is the most effective in this study. Subtraction arthrography and radionuclide arthrography are not suitable for use as routine methods for detection of total knee arthroplasty loosening.  相似文献   

2.
The main reason for the revision of total hip replacements is aseptic loosening, caused by stress shielding and wear particle induced osteolysis. In order to detect an implant loosening early, the osseointegration of endoprosthetic implants must be measured exactly. Currently applied diagnostic methods, such as standard radiographs and clinical symptomatology, often result in an imprecise diagnosis. A novel radiation-free method to improve the diagnostic investigation of implant loosening is presented. The osseointegration of an implant can be identified using mechanical magnetic sensors (oscillators), which impinge on small membranes inside an implant component, e.g., the femoral hip stem. The maximum velocity after impingement of the oscillator depends on the osseointegration of the implant. Excitation of the oscillator is realized by a coil outside the human body. Another external coil is used to detect the velocity of the oscillator. To demonstrate the principle of the novel loosening sensor, an overdimensioned test device was designed to measure simulated loosening phases in the first experimental tests with different material layers. The overdimensioned test device of the loosening sensor showed significant differences in the various phases of fixation. Analysis of the membrane without any material layer in the case of advanced loosening resulted in a 23% higher maximum velocity compared to an attached artificial bone layer. Based on these preliminary results, the sensor system shows potential for the detection of implant loosening. Moreover, the proposed system could be used in experimental applications to determine the quality of bioactive coatings and new implant materials.  相似文献   

3.
The purpose of this study was to identify factors which predispose to aseptic loosening of the femoral component in cemented total hip replacement. Its design was based on rigid selection critria, so that successful and loose replacements which employed the same surgical technique were compared. Measurements of patient anatomy and of the insertion of the femoral component were made, by an accurate computer technique, on initial post-operative radiographs. Loosening was associated with heavier patients with a wider medullary canal which was flared proximally. This difference in anatomy led to differing distributions of cement in the successful and loose replacements. Medial cement-bone demarcation, at the mid-stem level, was also associated with loosening. These findings indicate the importance of optimizing the size of the prosthesis with respect to the femoral morphology.  相似文献   

4.
The accuracy of digital Roentgen stereophotogrammetric analysis (RSA) was compared to the accuracy of a manually operated RSA system. For this purpose, we used radiographs of a phantom and radiographs of patients. The radiographs of the patients consisted of double examinations of 12 patients that had a tibial osteotomy and of double examinations of 12 patients that received a total hip prosthesis. First, the radiographs were measured manually with an accurate measurement table. Subsequently, the images were digitized by a film scanner at 150 DPI and 300 DPI resolutions and analyzed with the RSA-CMS software. In the phantom experiment, the manually operated system produced significantly better results than the digital system, although the maximum difference between the median values of the manually operated system and the digital system was as low as 0.013 mm for translations and 0.033° for rotations. In the radiographs of the patients, the manually operated system and the digital system produced equally accurate results: no significant differences in translations and rotations were found. We conclude that digital RSA is an accurate, fast, and user friendly alternative for manually operated RSA. Currently, digital RSA systems are being used in a growing number of clinical RSA-studies.  相似文献   

5.
AIMS: We prospectively analyzed the cancellous and cortical periprosthetic femoral bone reaction after implantation of a cementless total hip arthroplasty with computertomography assisted osteodensitometry after a mean of 1 and 6 years. MATERIALS AND METHODS: Twenty-one patients (? age at implantation: 52 years) with osteoarthrits of the hip joint received 21 cementless hip prostheses with a three-dimensionally tapered design. All patients were analyzed clinically, with CT-osteodensitometry and plain radiography after a mean of 10 days, at 1 and 6 years postoperatively. Cancellous and cortical bone density was evaluated automatically using a special software tool. RESULTS: The proximal region of the stem showed progessive cortical (? -15% 1 year, -25% 6 years post-OP) and cancellous (? -26% 1 year, -49% 6 years post-OP) bone density loss. Cortical bone density loss was lower and non-progressive at the diaphysis (? -7% 1 year, -9% 6 years post-OP) and the distal region (? -6% 1 year, -4% 6 years post-OP) of the stem. All stems showed no signs of loosening on plain radiography and good clinical results according to the Harris hip score. CONCLUSION: Computertomography assisted osteodensitometry is the only method which allows discrimination between periprosthetic cortical and cancellous bone density changes in vivo. The analyzed uncemented stem fixates at the diaphysis and distal region. Due to the changed biomechanical loading after stem implantation, progressive proximal cancellous bone density loss was measured for the first time in vivo. Its role in the pathogenesis of implant loosening is still unknown and needs to be further elucidated.  相似文献   

6.
Many physical anthropological studies require that an observer or device discriminate between states that can be easily confused. Receiver operating characteristic (ROC) analysis currently offers the best method for determining the accuracy of such choices, particularly for small sample sizes. Although ROC analysis is widely accepted in psychophysical and biomedical testing, its use in anthropological studies has not been reported. ROC analysis is used here to determine the usefulness of enhanced dental radiographs to assess vertical alveolar bone defects for quantitative studies of human variation with regard to periodontal disease. The presence or absence of vertical-bony defects (truth) for 75 human skulls was established by the consensus of two trained observers. Dental bitewing-radiographs were taken of the alveolar processes, the radiographs digitized, and the brightness and contrast of the digital images enhanced. The two observers who established truth then rated 1) plain bitewing radiographs, 2) unenhanced digital images of bitewings, and 3) enhanced digital images of bitewings for vertical bony defects. The rating scale varied from 1 (vertical defect definitely or almost definitely present) to 5 (definitely or almost definitely absent). ROC analysis was used to compared the diagnostic value of the 3 imaging modalities. All modalities had nearly identical diagnostic performance, measured as Az values (areas beneath ROC curves) that were less than 0.80, which indicates only moderate usefulness. It is concluded that enhancement does not increase success in vertical-bony-defect diagnosis from digital dental radiographs processed in this manner. Moreover, it is suggested that conventional bitewing radiographs may be unsuitable for accurate quantification of such defects.  相似文献   

7.
Callus formation occurs in the presence of secondary bone healing and has relevance to the fracture's mechanical environment. An objective image processing algorithm was developed to standardize the quantitative measurement of periosteal callus area in plain radiographs of long bone fractures. Algorithm accuracy and sensitivity were evaluated using surrogate models. For algorithm validation, callus formation on clinical radiographs was measured manually by orthopaedic surgeons and compared to non-clinicians using the algorithm. The algorithm measured the projected area of surrogate calluses with less than 5% error. However, error will increase when analyzing very small areas of callus and when using radiographs with low image resolution (i.e. 100 pixels per inch). The callus size extracted by the algorithm correlated well to the callus size outlined by the surgeons (R2=0.94, p<0.001). Furthermore, compared to clinician results, the algorithm yielded results with five times less inter-observer variance. This computational technique provides a reliable and efficient method to quantify secondary bone healing response.  相似文献   

8.
9.
目的:分析髋关节周围滑膜组织CD11b表达水平与人工髋关节置换术后无菌性松动的相关性。方法:以2006年5月至2016年5月于西京医院接受人工髋关节置换的患者为研究对象,对其髋关节周围滑膜组织进行CD11b免疫组化染色,并随访术后5年和10年无菌性松动的发生情况,通过单因素分析及logistic回归分析讨论CD11b表达与无菌性松动之间的相关性。结果:共300例患者纳入研究,全部获得随访,CD11b表达阳性患者163例,阳性率为54.33%;术后5年松动患者29例,术后5年无菌性松动发生率为9.67%;术后10年无菌性松动患者49例,术后10年无菌性松动发生率为16.33%;单因素分析结果表明CD11b表达阳性患者5年及10年松动率均高于CD11b表达阴性患者(P0.05);logistic回归分析结果表明CD11b过表达是髋关节置换术后无菌性松动发生的危险因素。结论:髋关节周围滑膜组织CD11b过表达是人工髋关节置换术后无菌性松动发生的危险因素,该分子或可作为无菌性松动的辅助诊断指标及潜在治疗靶点。  相似文献   

10.
目的:研究16层螺旋电子计算机断层扫描(CT)三维重建与数字化摄影(DR)平片检查对外伤性肋骨骨折的诊断价值,为临床诊治提供参考。方法:将2017年6月至2018年6月期间于本院接受诊治的82例外伤性肋骨骨折患者作为研究对象,所有患者均接受16层螺旋CT三维重建与DR平片检查,观察并记录患者的骨折发生部位,并比较两种诊断方法对外伤性肋骨骨折诊断的准确率、灵敏度、特异性、阳性预测值、阴性预测值以及漏诊情况。结果:82例外伤性肋骨骨折患者经影像学与临床诊断明确发生骨折179处,多发性骨折发生率为62.20%,单发性骨折发生率为37.80%,骨折肋骨段位中4-10段骨折发生率最高为69.83%,骨折肋骨水平阶段中腋肋骨折发生率最高为59.78%。相较于DR平片,16层螺旋CT三维重建诊断外伤性肋骨骨折的准确率、灵敏度、特异性、阳性预测值、阴性预测值更高,漏诊率更低,差异有统计学意义(P0.05)。结论:相较于DR平片检查,应用16层螺旋CT三维重建检查外伤性肋骨骨折能明显提高临床诊断的准确率、灵敏度和特异性,减少漏诊,可为临床诊治提供更可靠的信息,值得临床推广。  相似文献   

11.

Introduction

Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference.

Methods

We analyzed 3D intraoperative ultrasound in 39 patients with cerebral aneurysms to visualize the aneurysm intraoperatively and the nearby vascular tree before and after clipping. Simultaneous coregistration of preoperative subtraction angiography data with 3D intraoperative ultrasound was performed to verify the anatomical assignment.

Results

Intraoperative ultrasound detected 35 of 43 aneurysms (81%) in 39 patients. Thirty-nine intraoperative ultrasound measurements were matched with rotational digital subtraction angiography and were successfully reconstructed during the procedure. In 7 patients, the aneurysm was partially visualized by 3D-ioUS or was not in field of view. Post-clipping intraoperative ultrasound was obtained in 26 and successfully reconstructed in 18 patients (69%) despite clip related artefacts. The overlap between 3D-ioUS aneurysm volume and preoperative rDSA aneurysm volume resulted in a mean accuracy of 0.71 (Dice coefficient).

Conclusions

Intraoperative coregistration of 3D intraoperative ultrasound data with preoperative rotational digital subtraction angiography is possible with high accuracy. It allows the immediate visualization of vessels beyond the microscopic field, as well as parallel assessment of blood velocity, aneurysm and vascular tree configuration. Although spatial resolution is lower than for standard angiography, the method provides an excellent vascular overview, advantageous interpretation of 3D-ioUS and immediate intraoperative feedback of the vascular status. A prerequisite for understanding vascular intraoperative ultrasound is image quality and a successful match with preoperative rotational digital subtraction angiography.  相似文献   

12.

Purpose

Chronic hand and wrist pain is a common clinical issue for orthopaedic surgeons and rheumatologists. The purpose of this study was 1. To analyze the interobserver agreement of SPECT/CT, MRI, CT, bone scan and plain radiographs in patients with non-specific pain of the hand and wrist, and 2. to assess the diagnostic accuracy of these imaging methods in this selected patient population.

Materials and Methods

Thirty-two consecutive patients with non-specific pain of the hand or wrist were evaluated retrospectively. All patients had been imaged by plain radiographs, planar early-phase imaging (bone scan), late-phase imaging (SPECT/CT including bone scan and CT), and MRI. Two experienced and two inexperienced readers analyzed the images with a standardized read-out protocol. Reading criteria were lesion detection and localisation, type and etiology of the underlying pathology. Diagnostic accuracy and interobserver agreement were determined for all readers and imaging modalities.

Results

The most accurate modality for experienced readers was SPECT/CT (accuracy 77%), followed by MRI (56%). The best performing, though little accurate modality for inexperienced readers was also SPECT/CT (44%), followed by MRI and bone scan (38% each). The interobserver agreement of experienced readers was generally high in SPECT/CT concerning lesion detection (kappa 0.93, MRI 0.72), localisation (kappa 0.91, MRI 0.75) and etiology (kappa 0.85, MRI 0.74), while MRI yielded better results on typification of lesions (kappa 0.75, SPECT/CT 0.69). There was poor agreement between experienced and inexperienced readers in SPECT/CT and MRI.

Conclusions

SPECT/CT proved to be the most helpful imaging modality in patients with non-specific wrist pain. The method was found reliable, providing high interobserver agreement, being outperformed by MRI only concerning the typification of lesions. We believe it is beneficial to integrate SPECT/CT into the diagnostic imaging algorithm of chronic wrist pain.  相似文献   

13.
Finite element (FE) modelling has been proposed as a tool for estimating fracture risk and patient-specific FE models are commonly based on computed tomography (CT). Here, we present a novel method to automatically create personalised 3D models from standard 2D hip radiographs. A set of geometrical parameters of the femur were determined from seven ap hip radiographs and compared to the 3D femoral shape obtained from CT as training material; the error in reconstructing the 3D model from the 2D radiographs was assessed. Using the geometry parameters as the input, the 3D shape of another 21 femora was built and meshed, separating a cortical and trabecular compartment. The material properties were derived from the homogeneity index assessed by texture analysis of the radiographs, with focus on the principal tensile and compressive trabecular systems. The ability of these FE models to predict failure load as determined by experimental biomechanical testing was evaluated and compared to the predictive ability of DXA. The average reconstruction error of the 3D models was 1.77 mm (±1.17 mm), with the error being smallest in the femoral head and neck, and greatest in the trochanter. The correlation of the FE predicted failure load with the experimental failure load was r2=64% for the reconstruction FE model, which was significantly better (p<0.05) than that for DXA (r2=24%). This novel method for automatically constructing a patient-specific 3D finite element model from standard 2D radiographs shows encouraging results in estimating patient-specific failure loads.  相似文献   

14.
Background: Hydroxyapatite coated (HAC) hip implants have been used in clinical practice for more than two decades. However, the majority of studies have reported only intermediate term outcomes that are not reliable for predicting long-term behavior in all implants. The aim of this study was to determine the performance of HAC total hip arthroplasty in younger patients over a 10-year follow-up period. Methods and Results: This was an observational retrospective study of a 137 consecutive hips with the ABG I prosthesis. Of these, 128 were available for the last investigation. Median duration of follow-up was 10.9 years. The mean age at time of index surgery was 46+/-6.7 years. Probability of implant survival was estimated using the Kaplan-Meier method. The overall 12-year cumulative survival was 0.55 (95% CI, 0.443-0.659). Periprosthetic osteolysis (57 %) was the most frequent reason for failure followed by aseptic loosening (28 %). When only aseptic loosening was included in the analysis, the same figures for cup and stem were 0.873 (95% CI, 0.808-0.938) and 0.992 (95% CI, 0.976- 1.0), respectively. Patients with a smaller cup size were those at high risk for revision due to wear-related complications (odds ratio, OR=4.3; 95% CI, 1.734-10.555). Conclusion: This study reports one of the poorest 12-year survivorship data for cementless acetabular component in the literature. The main reason for premature failure was osteolysis, strongly related to high wear rate of polyethylene.  相似文献   

15.
Finite element simulation of early creep and wear in total hip arthroplasty   总被引:4,自引:0,他引:4  
Polyethylene wear particulate has been implicated in osteolytic lesion development and may lead to implant loosening and revision surgery. Wear in total hip arthroplasty is frequently estimated from patient radiographs by measurement of penetration of the femoral head into the polyethylene liner. Penetration, however, is multi-factorial, and includes components of wear and deformation due to creep. From a clinical perspective, it is of great interest to separate these elements to better evaluate true wear rates in vivo. Thus, the aim of this study was to determine polyethylene creep and wear penetration and volumetric wear during simulated gait loading conditions for variables of head size, liner thickness, and head–liner clearance. A finite element model of hip replacement articulation was developed, and creep and wear simulation was performed to 1 million gait cycles. Creep of the liner occurred quickly and increased the predicted contact areas by up to 56%, subsequently reducing contact pressures by up to 41%. Greater creep penetration was found with smaller heads, thicker liners, and larger clearance. The least volumetric wear but the most linear penetration was found with the smallest head size. Although polyethylene thickness increases from 4 to 16 mm produced only slight increases in volumetric wear and modest effects on total penetration, the fraction of creep in total penetration varied with thickness from 10% to over 50%. With thicker liners and smaller heads, creep will comprise a significant fraction of early penetration. These results will aid an understanding of the complex interaction of creep and wear.  相似文献   

16.
目的:探讨大直径陶瓷-陶瓷假体对髋关节置换患者术后假体磨损,稳定性和髋关节功能的影响。方法:选取我院2010年1月-2014年1月间采用大直径陶瓷-陶瓷假体行关全髋置换的股骨头坏死患者46例作为研究组。另选40例采用标准金属-聚乙烯假体手术患者作为对照组。观察并比较两组患者假体磨损情况、髋关节稳定性和功能评分。结果:研究组患者术后无一例脱位,发生假体松动1例,Harris评分为(82.04±1.92)分;对照组术后发生假体脱位4例,松动4例,Harris评分为(81.37±1.27)分;研究组假体稳定性和磨损程度优于对照组,差异具有统计学意义(P0.05),但两组髋关节功能评分无显著差异(P0.05)。发生假体松动的患者术后血沉、IL-1和IL-6浓度均高于正常值,差异具有统计学意义(P0.05)。结论:与标准假体相比,大直径陶瓷-陶瓷假体稳定性好,磨损率低,是全髋置换手术的良好假体。  相似文献   

17.
OBJECTIVE--To determine whether gonad shields are correctly positioned on the pelvic radiographs of children with slipped capital femoral epiphysis. DESIGN--Retrospective study of radiographs taken of children treated by in situ pinning of slipped capital femoral epiphysis between 1 January 1983 and 31 December 1988. SETTING--Three teaching hospitals in north west England. PATIENTS--32 patients with complete set of radiographs. RESULTS--An average of 10.8 anteroposterior pelvic radiographs plus 8.9 lateral hip radiographs had been performed per patient. Gonad shields had been completely omitted in 137 (40%) anteroposterior pelvic radiographs performed on the 32 patients at the time of completion of the study. In 100 (29%) the gonad shields were adequately protecting the gonads, but in 109 (31%) the gonad shields were not protecting the gonads due to incorrect positioning of the shield. The incorrect positioning of the gonad shields was more commonly found in girls than boys (64 vs 45; p less than 0.012), presumably because of the difficulty in determining gonadal position in relation to surface landmarks. Absence of gonad shields was also more commonly seen in girls (82 v 55; p less than 0.005), but this is not easily explained. CONCLUSIONS--Gonad shields are not protecting the gonads in a large percentage of anteroposterior pelvic radiographs (71%) because they have been omitted or inadequately placed. This avoidable excess radiation exposure to the gonads, combined with the inability to shield the gonads in lateral hip radiographs and the large number of radiographs performed, results in the gonads receiving a higher dose of radiation than may otherwise be the case, and may increase the potential for disease in the future offspring of these patients.  相似文献   

18.
目的:探讨全髋关节置换术治疗晚期非创伤性股骨头缺血性坏死的临床疗效,为临床治疗提供参考依据.方法:将我院进行全髋关节置换术治疗晚期股骨头缺血性坏死患者25例(30髋)按病因分三组,A组酒精性17例,B组为激素性6例,C组潜水性2例,记录各组患者术前、术后的临床症状,患髋功能,X片等,并进行Harris评分,对结果进行评价分析.结果:三组术后Harris评分分别为(89.7±2.8)、(81.5±3.1)分、(87.8±2.9)分,经方差分析,差异有统计学意义(P<0.05);三组术后假肢松动髋数率分别为4.8%、16.7%、0%,经卡方检验,差异有统计学意义(P<0.05);三组术后随访3年总体髋部优良率分别为100%、83.3%、100%,经卡方检验,差异有统计学意义(P<0.05).结论:全髋关节置换术治疗晚期非创伤性股骨头缺血性坏死疗效较好,对酒精性病因患者疗效最好.  相似文献   

19.
王晶  祝铭  庄玲玲  张皓  朱颖 《生物磁学》2014,(12):2271-2273
目的:探讨研究冠状动脉CT造影检查对冠心病的临床诊断价值。方法:收集我院2012年1月至2013年10月共计70例临床怀疑为冠心病的患者,对这些患者分别进行冠状动脉CT造影检查和数字减影冠状动脉造影(DSA)检查,记录这两项检查所得结果及数据,以检查数据为基础对冠状动脉CT造影和数字减影冠状动脉造影检查的临床实验效果进行对比研究。结果:70例病人均可顺利完成以上两种检查,按照数字减影冠状动脉造影检查的标准,冠状动脉CT造影的敏感度为92.2%,特异度为97.4%、阳性预测率为90.5%、阴性预测率98%。结论:相对于数字减影冠状动脉造影检查,冠状动脉CT造影检查是一种更加安全、可靠、无创且更具临床指导意义的检测技术,因此可以推荐作为冠心病诊断的首选方法。  相似文献   

20.
目的:探讨研究冠状动脉CT造影检查对冠心病的临床诊断价值。方法:收集我院2012年1月至2013年10月共计70例临床怀疑为冠心病的患者,对这些患者分别进行冠状动脉CT造影检查和数字减影冠状动脉造影(DSA)检查,记录这两项检查所得结果及数据,以检查数据为基础对冠状动脉CT造影和数字减影冠状动脉造影检查的临床实验效果进行对比研究。结果:70例病人均可顺利完成以上两种检查,按照数字减影冠状动脉造影检查的标准,冠状动脉CT造影的敏感度为92.2%,特异度为97.4%、阳性预测率为90.5%、阴性预测率98%。结论:相对于数字减影冠状动脉造影检查,冠状动脉CT造影检查是一种更加安全、可靠、无创且更具临床指导意义的检测技术,因此可以推荐作为冠心病诊断的首选方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号