首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Venous bypass grafts often fail following arterial implantation due to excessive smooth muscle cells (VSMC) proliferation and consequent intimal hyperplasia (IH). Intercellular communication mediated by Connexins (Cx) regulates differentiation, growth and proliferation in various cell types. Microarray analysis of vein grafts in a model of bilateral rabbit jugular vein graft revealed Cx43 as an early upregulated gene. Additional experiments conducted using an ex-vivo human saphenous veins perfusion system (EVPS) confirmed that Cx43 was rapidly increased in human veins subjected ex-vivo to arterial hemodynamics. Cx43 knock-down by RNA interference, or adenoviral-mediated overexpression, respectively inhibited or stimulated the proliferation of primary human VSMC in vitro. Furthermore, Cx blockade with carbenoxolone or the specific Cx43 inhibitory peptide 43gap26 prevented the burst in myointimal proliferation and IH formation in human saphenous veins. Our data demonstrated that Cx43 controls proliferation and the formation of IH after arterial engraftment.  相似文献   

2.
Vein graft adaptation to the arterial environment is characterized by loss of venous identity, with reduced Ephrin type-B receptor 4 (Eph-B4) expression but without increased Ephrin-B2 expression. We examined changes of vessel identity of human saphenous veins in a flow circuit in which shear stress could be precisely controlled. Medium circulated at arterial or venous magnitudes of laminar shear stress for 24 hours; histologic, protein, and RNA analyses of vein segments were performed. Vein endothelium remained viable and functional, with platelet endothelial cell adhesion molecule (PECAM)-expressing cells on the luminal surface. Venous Eph-B4 expression diminished (p = .002), Ephrin-B2 expression was not induced (p = .268), and expression of osteopontin (p = .002) was increased with exposure to arterial magnitudes of shear stress. Similar changes were not found in veins placed under venous flow or static conditions. These data show that human saphenous veins remain viable during ex vivo application of shear stress in a bioreactor, without loss of the venous endothelium. Arterial magnitudes of shear stress cause loss of venous identity without gain of arterial identity in human veins perfused ex vivo. Shear stress alone, without immunologic or hormonal influence, is capable of inducing changes in vessel identity and, specifically, loss of venous identity.  相似文献   

3.
Vein graft failure remains an important clinical challenge, but factors contributing to vein graft failure have not clearly been defined. We investigated the role of the mechanical environment in vein remodeling in an ex vivo perfusion system. Porcine saphenous veins were subjected to five different ex vivo hemodynamic environments, including one mimicking an arterial bypass graft, for one week in order to independently assess the effects of shear stress and pressure on vein remodeling. The extent of intimal hyperplasia decreased with culture under increasing shear stress, with veins cultured under the lowest levels of shear stress exhibiting the greatest ratio of intimal/medial area, 0.15+/-0.03, which was greater than that of fresh veins (0.06+/-0.01, p<0.05). All perfused veins displayed characteristics of both medial hypertrophy and eutrophic remodeling, with those veins cultured under elevated pressures showing greater increases in mass and area than those cultured under venous pressures. Medial area correlated with the average pressure under which veins were cultured (R2=0.95, p<0.001), with veins cultured under bypass graft conditions, which were exposed to the greatest pressure during the one week culture, exhibiting the largest medial area (1.69+/-0.15 mm2), which was significantly greater than that of fresh veins (1.08+/-0.05 mm2, p<0.05). However, pulsatility was not a necessary stimulus for medial growth, as increases in medial area were observed in culture conditions in which steady flow and pressure were present. Our results suggest that pressure and shear stress act independently to regulate vein remodeling, influencing changes in vessel size as well as the nature of the remodeling.  相似文献   

4.
The failure of vein graft conduits implanted in the arterial circulation has been hypothesized to occur in part due to the exposure of the graft to altered biomechanical and fluid shearing forces. In the present study, these forces are characterized for canine internal jugular veins (IJV) exposed to realistic arterial flow dynamics. Freshly excised vein segments were mounted into a pulsatile perfusion apparatus and exposed to arterial flow conditions (P = 115/75 mmHg and Q = 110 ml min-1) for 2 h. Dynamic measurements of intraluminal pressure and flow rate and vessel wall radial distension were acquired to accurately quantitate the incremental modulus of elasticity; hoop, axial and radial wall stresses; and fluid shearing forces within the vessel. Identical measurements were performed on canine carotid arteries (CCA) to serve as a comparison. Under arterial conditions, IJV segments demonstrated a significant elevation (p less than 0.05) over the CCA in the incremental elasticity modulus, along with a corresponding elevation in hoop and axial wall stresses. Additionally the average wall shearing rate to which the IJV endothelial surface was exposed was a factor of six less than that observed in the CCA. These results are discussed in relationship to the clinical situation of vein graft adaptation to arterial hemodynamics.  相似文献   

5.
When grafted into an arterial environment in vivo, veins remodel in response to the new mechanical environment, thereby changing their mechanical properties and potentially impacting their patency as bypass grafts. Porcine saphenous veins were subjected for one week to four different ex vivo hemodynamic environments in which pressure and shear stress were varied independently, as well as an environment that mimicked that of an arterial bypass graft. After one week of ex vivo culture, the mechanical properties of intact saphenous veins were evaluated to relate specific aspects of the mechanical environment to vein remodeling and corresponding changes in mechanics. The compliance of all cultured veins tended to be less than that of fresh veins; however, this trend was more due to changes in medial and luminal areas than changes in the intrinsic properties of the vein wall. A combination of medial hypertrophy and eutrophic remodeling leads to significantly smaller (p<0.05) wall stresses measured in all cultured veins except those subjected to bypass graft conditions relative to stresses measured in fresh veins at corresponding pressures. Our results suggest that the mechanical environment effects changes in vessel size, as well as the nature of the remodeling, which contribute to altering vein mechanical properties.  相似文献   

6.
The microvascular function of nitric oxide (NO) during ischemia-reperfusion (I/R) in intermittent hypoxia (IH)-pretreated hamsters was analyzed using 20 mg/kg of the nonselective NO inhibitor N(omega)-nitro-l-arginine methyl ester (l-NAME) and 5 mg/kg of the preferential inducible NO inhibitor S-methylisothiourea sulphate (SMT) injected before I/R. Studies were made in the hamster cheek pouch microcirculation (intravital fluorescence microscopy). IH consisted of 6 min of 8% O(2) breathing followed by 6 min of 21% O(2) for every 8 h for 21 days. Normoxia controls (NCs) were exposed to room air for the same period. The effects were characterized in terms of systemic hemodynamics, diameter, flow, wall shear stress in arterioles, capillary perfusion, and the concentrations of thiobarbituric acid-reactive substances (TBARS) and plasma NO, assessed as nitrite/nitrate (NOx) levels. IH did not change arterial blood pressure and increased hematocrit and shear stress. IH increased NOx and TBARS levels and reduced arterial diameter, blood flow, and capillary perfusion versus the NC. Conversely, TBARS and NOx were lower during I/R in IH-pretreated hamsters, resulting in vasodilation and the increase of capillary perfusion and shear stress. After IH, capillary perfusion was reduced by 24% (2.3%) and enhanced by 115% (1.7%) after I/R (P < 0.05). Both modalities of NO blockade decreased NOx generation and increased TBARS versus IH. l-NAME and SMT induced a significant decrease in arteriolar diameter, blood flow, and capillary perfusion (P < 0.05). l-NAME enhanced TBARS more than SMT and aggravated I/R damage. In conclusion, we demonstrated that preconditioning with IH greatly reduces oxidative stress and stimulates NO-induced vasodilation during I/R injury, thus maintaining capillary perfusion.  相似文献   

7.
8.
The use of ex vivo perfused models can mimic the physiological conditions of the liver for short periods, but to maintain normal homeostasis for an extended perfusion period is challenging. We have added the kidney to our previous ex vivo perfused liver experiment model to reproduce a more accurate physiological state for prolonged experiments without using live animals. Five intact livers and kidneys were retrieved post-mortem from sacrificed pigs on different days and perfused for a minimum of 6 hr. Hourly arterial blood gases were obtained to analyze pH, lactate, glucose and renal parameters. The primary endpoint was to investigate the effect of adding one kidney to the model on the acid base balance, glucose, and electrolyte levels. The result of this liver-kidney experiment was compared to the results of five previous liver only perfusion models. In summary, with the addition of one kidney to the ex vivo liver circuit, hyperglycemia and metabolic acidosis were improved. In addition this model reproduces the physiological and metabolic responses of the liver sufficiently accurately to obviate the need for the use of live animals. The ex vivo liver-kidney perfusion model can be used as an alternative method in organ specific studies. It provides a disconnection from numerous systemic influences and allows specific and accurate adjustments of arterial and venous pressures and flow.  相似文献   

9.
The present study was to test the hypothesis that anti-arrhythmic properties of verapamil may be accompanied by preserving connexin43 (Cx43) protein via calcium influx inhibition. In an in vivo study, myocardial ischemic arrhythmia was induced by occlusion of the left anterior descending (LAD) coronary artery for 45 min in Sprague-Dawley rats. Verapamil, a calcium channel antagonist, was injected i.v. into a femoral vein prior to ischemia. Effects of verapamil on arrhythmias induced by Bay K8644 (a calcium channel agonist) were also determined. In an ex vivo study, the isolated heart underwent an initial 10 min of baseline normal perfusion and was subjected to high calcium perfusion in the absence or presence of verapamil. Cardiac arrhythmia was measured by electrocardiogram (ECG) and Cx43 protein was determined by immunohistochemistry and western blotting. Administration of verapamil prior to myocardial ischemia significantly reduced the incidence of ventricular arrhythmias and total arrhythmia scores, with the reductions in heat rate, mean arterial pressure and left ventricular systolic pressure. Verapamil also inhibited arrhythmias induced by Bay K8644 and high calcium perfusion. Effect of verapamil on ischemic arrhythmia scores was abolished by heptanol, a Cx43 protein uncoupler and Gap 26, a Cx43 channels inhibitor. Immunohistochemistry data showed that ischemia-induced redistribution and reduced immunostaining of Cx43 were prevented by verapamil. In addition, diminished expression of Cx43 protein determined by western blotting was observed following myocardial ischemia in vivo or following high calcium perfusion ex vivo and was preserved after verapamil administration. Our data suggest that verapamil may confer an anti-arrhythmic effect via calcium influx inhibition, inhibition of oxygen consumption and accompanied by preservation of Cx43 protein.  相似文献   

10.
When vein segments are implanted into the arterial system for use in arterial bypass grafting, adaptation to the higher pressure and flow of the arterial system is accomplished thorough wall thickening and expansion. These early remodeling events have been found to be closely coupled to the local hemodynamic forces, such as shear stress and wall tension, and are believed to be the foundation for later vein graft failure. To further our mechanistic understanding of the cellular and extracellular interactions that lead to global changes in tissue architecture, a rule-based modeling method is developed through the application of basic rules of behaviors for these molecular and cellular activities. In the current method, smooth muscle cell (SMC), extracellular matrix (ECM), and monocytes are selected as the three components that occupy the elements of a grid system that comprise the developing vein graft intima. The probabilities of the cellular behaviors are developed based on data extracted from in vivo experiments. At each time step, the various probabilities are computed and applied to the SMC and ECM elements to determine their next physical state and behavior. One- and two-dimensional models are developed to test and validate the computational approach. The importance of monocyte infiltration, and the associated effect in augmenting extracellular matrix deposition, was evaluated and found to be an important component in model development. Final model validation is performed using an independent set of experiments, where model predictions of intimal growth are evaluated against experimental data obtained from the complex geometry and shear stress patterns offered by a mid-graft focal stenosis, where simulation results show good agreements with the experimental data.  相似文献   

11.
The potassium channel blocker tetraethylammonium blocks the flow-induced increase in endothelial ICAM-1. We have investigated the subtype of potassium channel that modulates flow-induced increased expression of ICAM-1 on saphenous vein endothelium. Cultured human saphenous vein endothelial cells (HSVECs) or intact saphenous veins were perfused at fixed low and high flows in a laminar shear chamber or flow rig, respectively, in the presence or absence of potassium channel blockers. Expression of K(+) channels and endothelial ICAM-1 was measured by real-time polymerase chain reaction and/or immunoassays. In HSVECs, the application of 0.8 N/m(2) (8 dyn/cm(2)) shear stress resulted in a two- to fourfold increase in cellular ICAM-1 within 6 h (P < 0.001). In intact vein a similar shear stress, with pulsatile arterial pressure, resulted in a twofold increase in endothelial ICAM-1/CD31 staining area within 1.5 h (P < 0.001). Both increases in ICAM-1 were blocked by inclusion of 100 nM apamin in the vein perfusate, whereas other K(+) channel blockers were less effective. Two subtypes of small conductance Ca(2+)-activated K(+) channel (selectively blocked by apamin) were expressed in HSVECs and vein endothelium (SK3>SK2). Apamin blocked the upregulation of ICAM-1 on saphenous vein endothelium in response to increased flow to implicate small conductance Ca(2+)-activated K(+) channels in shear stress/flow-mediated signaling pathways.  相似文献   

12.
The success of liver transplantation has resulted in a dramatic organ shortage. In most transplant regions 20-30% of patients on the waiting list for liver transplantation die without receiving an organ transplant or are delisted for disease progression. One strategy to increase the donor pool is the utilization of marginal grafts, such as fatty livers, grafts from older donors, or donation after cardiac death (DCD). The current preservation technique of cold static storage is only poorly tolerated by marginal livers resulting in significant organ damage. In addition, cold static organ storage does not allow graft assessment or repair prior to transplantation.These shortcomings of cold static preservation have triggered an interest in warm perfused organ preservation to reduce cold ischemic injury, assess liver grafts during preservation, and explore the opportunity to repair marginal livers prior to transplantation. The optimal pressure and flow conditions, perfusion temperature, composition of the perfusion solution and the need for an oxygen carrier has been controversial in the past.In spite of promising results in several animal studies, the complexity and the costs have prevented a broader clinical application so far. Recently, with enhanced technology and a better understanding of liver physiology during ex vivo perfusion the outcome of warm liver perfusion has improved and consistently good results can be achieved.This paper will provide information about liver retrieval, storage techniques, and isolated liver perfusion in pigs. We will illustrate a) the requirements to ensure sufficient oxygen supply to the organ, b) technical considerations about the perfusion machine and the perfusion solution, and c) biochemical aspects of isolated organs.  相似文献   

13.
The long-term success of arterial bypass grafting with autologous saphenous veins is limited by neointimal hyperplasia (NIH), which seemingly develops preferentially at sites where hydrodynamic wall shear is low. Placement of a loose-fitting, porous stent around end-to-end, or end-to-side, autologous saphenous vein grafts on the porcine common carotid artery has been found significantly to reduce NIH, but the mechanism is unclear. In a preliminary study, we implanted autologous saphenous vein grafts bilaterally on the common carotid arteries of pigs, placing a stent around one graft and leaving the contralateral graft unstented. At sacrifice 1 month post implantation, the grafts were pressure fixed in situ and resin casts were made. Unstented graft geometry was highly irregular, with non-uniform dilatation, substantial axial lengthening, curvature, kinking, and possible long-pitch helical distortion. In contrast, stented grafts showed no major dilatation, lengthening or curvature, but there was commonly fine corrugation, occasional slight kinking or narrowing of segments, and possible long-pitch helical distortion. Axial growth of grafts against effectively tethered anastomoses could account for these changes. CFD studies are planned, using 3D MR reconstructions, on the effects of graft geometry on the flow. Abnormality of the flow could favour the development of vascular pathology, including NIH.  相似文献   

14.
15.
Research studies over the last three decades have established that hemodynamic interactions with the vascular surface as well as surgical injury are inciting mechanisms capable of eliciting distal anastomotic intimal hyperplasia (IH) and ultimate bypass graft failure. While abnormal wall shear stress (WSS) conditions have been widely shown to affect vascular biology and arterial wall self-regulation, the near-wall localization of critical blood particles by convection and diffusion may also play a significant role in IH development. It is hypothesized that locations of elevated platelet interactions with reactive or activated vascular surfaces, due to injury or endothelial dysfunction, are highly susceptible to IH initialization and progression. In an effort to assess the potential role of platelet-wall interactions, experimentally validated particle-hemodynamic simulations have been conducted for two commonly implemented end-to-side anastomotic configurations, with and without proximal outflow. Specifically, sites of significant particle interactions with the vascular surface have been identified by a novel near-wall residence time (NWRT) model for platelets, which includes shear stress-based factors for platelet activation as well as endothelial cell expression of thrombogenic and anti-thrombogenic compounds. Results indicate that the composite NWRT model for platelet-wall interactions effectively captures a reported shift in significant IH formation from the arterial floor of a relatively high-angle (30 deg) graft with no proximal outflow to the graft hood of a low-angle graft (10 deg) with 20% proximal outflow. In contrast, other WSS-based hemodynamic parameters did not identify the observed system-dependent shift in IH formation. However, large variations in WSS-vector magnitude and direction, as encapsulated by the WSS-gradient and WSS-angle-gradient parameters, were consistently observed along the IH-prone suture-line region. Of the multiple hemodynamic factors capable of eliciting a hyperplastic response at the cellular level, results of this study indicate the potential significance of platelet-wall interactions coinciding with regions of low WSS in the development of IH.  相似文献   

16.
In order to cause endovascular infections and infective endocarditis, bacteria need to be able to adhere to the vessel wall while being exposed to the shear stress of flowing blood.To identify the bacterial and host factors that contribute to vascular adhesion of microorganisms, appropriate models that study these interactions under physiological shear conditions are needed. Here, we describe an in vitro flow chamber model that allows to investigate bacterial adhesion to different components of the extracellular matrix or to endothelial cells, and an intravital microscopy model that was developed to directly visualize the initial adhesion of bacteria to the splanchnic circulation in vivo. These methods can be used to identify the bacterial and host factors required for the adhesion of bacteria under flow. We illustrate the relevance of shear stress and the role of von Willebrand factor for the adhesion of Staphylococcus aureus using both the in vitro and in vivo model.  相似文献   

17.
The effectiveness of localized retrograde coronary venous perfusion (RCVP) in preventing or reversing myocardial ischemia after acute ligation of a coronary artery is described. Ten domestic pigs (Group I) underwent aorto left anterior coronary vein grafting with RCVP at systemic pressure. In another set of ten pigs (Group II), the coronary vein was similarly grafted, but the proximal end of the graft was perfused with oxygenated blood by means of an external pump at reduced pressure and flow. In both groups, RCVP successfully reversed the mechanical or electrical effects produced by 2 to 5 minutes of acute arterial ligation. After several hours, Group I animals showed evidence of acute ischemia and developing infarction. Group II animals, however, were maintained for 7 hours or more with regional RCVP and no evidence of ischemia. Retrograde coronary venous perfusion at reduced pressure may be more effective than perfusion at systemic pressure in providing myocardial blood flow.  相似文献   

18.
19.

Background

Coronary artery bypass grafting surgery is an effective treatment modality for patients with severe coronary artery disease. The conduits used during the surgery include both the arterial and venous conduits. Long- term graft patency rate for the internal mammary arterial graft is superior, but the same is not true for the saphenous vein grafts. At 10 years, more than 50% of the vein grafts would have occluded and many of them are diseased. Why do the saphenous vein grafts fail the test of time? Many causes have been proposed for saphenous graft failure. Some are non-modifiable and the rest are modifiable. Non-modifiable causes include different histological structure of the vein compared to artery, size disparity between coronary artery and saphenous vein. However, researches are more interested in the modifiable causes, such as graft flow dynamics and wall shear stress distribution at the anastomotic sites. Formation of intimal hyperplasia at the anastomotic junction has been implicated as the root cause of long- term graft failure.Many researchers have analyzed the complex flow patterns in the distal sapheno-coronary anastomotic region, using various simulated model in an attempt to explain the site of preferential intimal hyperplasia based on the flow disturbances and differential wall stress distribution. In this paper, the geometrical bypass models (aorto-left coronary bypass graft model and aorto-right coronary bypass graft model) are based on real-life situations. In our models, the dimensions of the aorta, saphenous vein and the coronary artery simulate the actual dimensions at surgery. Both the proximal and distal anastomoses are considered at the same time, and we also take into the consideration the cross-sectional shape change of the venous conduit from circular to elliptical. Contrary to previous works, we have carried out computational fluid dynamics (CFD) study in the entire aorta-graft-perfused artery domain. The results reported here focus on (i) the complex flow patterns both at the proximal and distal anastomotic sites, and (ii) the wall shear stress distribution, which is an important factor that contributes to graft patency.

Methods

The three-dimensional coronary bypass models of the aorto-right coronary bypass and the aorto-left coronary bypass systems are constructed using computational fluid-dynamics software (Fluent 6.0.1). To have a better understanding of the flow dynamics at specific time instants of the cardiac cycle, quasi-steady flow simulations are performed, using a finite-volume approach. The data input to the models are the physiological measurements of flow-rates at (i) the aortic entrance, (ii) the ascending aorta, (iii) the left coronary artery, and (iv) the right coronary artery.

Results

The flow field and the wall shear stress are calculated throughout the cycle, but reported in this paper at two different instants of the cardiac cycle, one at the onset of ejection and the other during mid-diastole for both the right and left aorto-coronary bypass graft models. Plots of velocity-vector and the wall shear stress distributions are displayed in the aorto-graft-coronary arterial flow-field domain. We have shown (i) how the blocked coronary artery is being perfused in systole and diastole, (ii) the flow patterns at the two anastomotic junctions, proximal and distal anastomotic sites, and (iii) the shear stress distributions and their associations with arterial disease.

Conclusion

The computed results have revealed that (i) maximum perfusion of the occluded artery occurs during mid-diastole, and (ii) the maximum wall shear-stress variation is observed around the distal anastomotic region. These results can enable the clinicians to have a better understanding of vein graft disease, and hopefully we can offer a solution to alleviate or delay the occurrence of vein graft disease.
  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号