首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Improved Membrane Filter Method for Fecal Coliform Analysis   总被引:26,自引:24,他引:2       下载免费PDF全文
A two-layer agar method has been developed which consistently yields higher recovery of fecal coliforms on membrane filters when compared to the existing membrane fecal coliform procedure. This method has been evaluated by three laboratories using samples of raw and chlorinated waste water, and reservoir, river, and marine waters. Verification of 1,013 fecal coliform colonies isolated from 61 water samples averaged 92% on this proposed procedure. Comparison with the Standard Methods membrane fecal coliform procedure revealed the two-layer agar method had an overall increased sensitivity to fecal coliform detection in these waters. It is therefore proposed that this procedure be evaluated as an alternative to the Standard Methods fecal coliform membrane Filter test in the examination of chlorinated secondary effluents, marine waters, and any natural waters that may contain pollutants with heavy metal ions.  相似文献   

2.
In a comparison of two commonly used membrane filters for enumerating fecal coliform bacteria it was demonstrated that Seitz type M filters recovered statistically more colonies of bacteria than did Millipore HAWG 047S1 filters from pure cultures of Escherichia coli incubated at 44 °C. The membranes were grown on 0.4 % Teepol agar. On incubation at 37°C no significant discrepancy was found. As a reference method was used pour plating in plate count agar (Difco). It was demonstrated that incubation at 44°C did not per se inhibit propagation of fecal coliforms. Both types of filters examined were sterilized by the manufacturers with ethylene oxide. The discrepancy found can therefore not be due to sterilization procedures.  相似文献   

3.
Millipore type HA and HC membrane filters were compared for recoveries of total coliforms, fecal coliforms and fecal streptococci from natural waters and wastewater effluents. Bacterial and fecal coliform recovery was better on HC than on HA filters.  相似文献   

4.
m-T7 agar, designed to improve recoveries of injured total coliforms, was evaluated for its effectiveness as a fecal coliform medium. The time and temperature of preincubation were found to be crucial to the optimal recovery of fetal coliforms. Isolation rates for fecal coliforms on m-T7 agar from sewage effluents were the highest when plates were preincubated at 37 degrees C for 8 h before transfer to 44.5 degrees C for 12 h. The medium was found to produce consistently higher fecal coliform counts than all the other methods tested. Recoveries were 3.1 times greater than the standard m-FC method and 1.7 times greater than the two-layer enrichment, temperature acclimation procedure. Verification rates for fecal coliforms isolated on m-T7 agar averaged 89.0%, whereas verification rates for m-FC agar averaged only 82.8%. Both media isolated similar fecal coliform populations. The advantages of a single medium, highly effective for the isolation of both total and fecal coliforms, are discussed.  相似文献   

5.
Tests of two leading brands of membrane filters used for enumerating fecal coliform bacteria showed that Gelman GN-6 filters recovered statistically more colonies of bacteria than did Millipore HAWG 047SO filters from pure cultures incubated at either 35 C (the optimal growth temperature) or 44.5 C (the standard temperature for the fecal coliform test). Standard membrane filter procedures with M-FC broth base were used to enumerate the organisms. Densities of colonies incubated on Gelman filters at 44.5 C averaged 2.3 times greater than those on Millipore filters. Plate counts of the bacteria at both temperatures indicated that incubation at 44.5 C did not inhibit propagation of fecal coliform bacteria. For the pour plates, M-FC broth base plus 1.5% agar was used. This modified medium compared favorably to plate count agar for enumerating Escherichia coli. At 35 and 44.5 C, colony counts on Gelman filters agreed closely with plate counts prepared concurrently, but Millipore counts were consistently lower than plate counts, especially at 44.5 C. Comparative analyses of river water for fecal coliform bacteria by the membrane filter technique gave results comparable to those for the pure cultures.  相似文献   

6.
MacConkey agar, standard M-FC agar, M-FC agar without rosolic acid, M-FC agar with a resuscitation top layer, Teepol agar, and pads saturated with Teepol broth, were evaluated as growth media for membrane filtration counting of fecal coliform bacteria in water. In comparative tests on 312 samples of water from a wide variety of sources, including chlorinated effluents, M-FC agar without rosolic acid proved the medium of choice because it generally yielded the highest counts, was readily obtainable, easy to prepare and handle, and yielded clearly recognizable fecal coliform colonies. Identification of 1,139 fecal coliform isolates showed that fecal coliform tests cannot be used to enumerate Escherichia coli because the incidence of E. coli among fecal coliforms varied from an average of 51% for river water to 93% for an activated sludge effluent after chlorination. The incidence of Klebsiella pneumoniae among fecal coliforms varied from an average of 4% for the activated sludge effluent after chlorination to 32% for the river water. The advantages of a standard membrane filtration procedure for routine counting of fecal coliforms in water using M-FC agar without rosolic acid as growth medium, in the absence of preincubation or resuscitation steps, are outlined.  相似文献   

7.
Evaluation of m-T7 agar as a fecal coliform medium.   总被引:2,自引:2,他引:0       下载免费PDF全文
m-T7 agar, designed to improve recoveries of injured total coliforms, was evaluated for its effectiveness as a fecal coliform medium. The time and temperature of preincubation were found to be crucial to the optimal recovery of fetal coliforms. Isolation rates for fecal coliforms on m-T7 agar from sewage effluents were the highest when plates were preincubated at 37 degrees C for 8 h before transfer to 44.5 degrees C for 12 h. The medium was found to produce consistently higher fecal coliform counts than all the other methods tested. Recoveries were 3.1 times greater than the standard m-FC method and 1.7 times greater than the two-layer enrichment, temperature acclimation procedure. Verification rates for fecal coliforms isolated on m-T7 agar averaged 89.0%, whereas verification rates for m-FC agar averaged only 82.8%. Both media isolated similar fecal coliform populations. The advantages of a single medium, highly effective for the isolation of both total and fecal coliforms, are discussed.  相似文献   

8.
Methods for detecting total coliform bacteria in drinking water were compared using 1,483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a 10-tube fermentation tube (FT) technique, and the presence-absence (P-A) test. Each technique was evaluated using a 100-ml drinking water sample. Of the 1,483 samples tested, 336 (23%) contained coliforms as indicated by either one, two, or all three techniques. The FT detected 82%, the P-A detected 88%, and the MF detected 64% of these positives. All techniques simultaneously detected 55% of the positives. Evaluation of the confirmation efficiency of the P-A technique showed 94% of the presumptive positives confirming as coliforms. Thirteen different species of coliforms were identified from the 37 tests in which the P-A was positive but the MF and FT were negative. The P-A test was simple to inoculate and interpret and was considerably more sensitive than the MF and slightly more sensitive than the FT in detecting coliforms in this type of drinking water supply.  相似文献   

9.
Autoclave and ethylene oxide-sterilized membrane filters manufactured by Gelman, Millipore, and Sartorius were field tested for their recovery of total coliforms, fecal coliforms, fecal streptococci, and heterotrophs. The data were analyzed by using split-plot analysis of variance and significance tests. Membranes were also tested for pH and toxicity using Escherichia coli. The mean data summaries indicated that Gelman membrane filters generally produced the highest counts during the field studies. Statistical analyses of the March data showed that there were significant differences between membrane filters at 1% level; however, statistical analyses of June data revealed no significant differences except in total coliform recoveries. Toxicity tests at 35 C indicated that Gelman and Millipore autoclaved membrane filters were able to recover 92% of the test organisms. Toxicity tests performed at 44.5 C revealed that no membranes were able to recover more than 40% of the test organisms. Since differences were found in the ability of the three brands of membrane filters to recover bacteria from natural and controlled sources, membrane filters from different manufacturers cannot be readily interchanged. There is a need for a standardized procedure for testing bacterial recovery by membrane filters.  相似文献   

10.
Methods for detecting total coliform bacteria in drinking water were compared using 1,483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a 10-tube fermentation tube (FT) technique, and the presence-absence (P-A) test. Each technique was evaluated using a 100-ml drinking water sample. Of the 1,483 samples tested, 336 (23%) contained coliforms as indicated by either one, two, or all three techniques. The FT detected 82%, the P-A detected 88%, and the MF detected 64% of these positives. All techniques simultaneously detected 55% of the positives. Evaluation of the confirmation efficiency of the P-A technique showed 94% of the presumptive positives confirming as coliforms. Thirteen different species of coliforms were identified from the 37 tests in which the P-A was positive but the MF and FT were negative. The P-A test was simple to inoculate and interpret and was considerably more sensitive than the MF and slightly more sensitive than the FT in detecting coliforms in this type of drinking water supply.  相似文献   

11.
The repair detection procedure of Speck et al. (Appl. Microbiol. 29:549-550, 1975) was adapted for the enumeration of coliforms, fecal coliforms, and enterococci in seafood and environmental samples. Samples were pour plated with Trypticase soy agar, followed by a 1- to 2-h incubation to effect repair; the plates were then overlaid with the selective medium and incubated. Violet red bile agar and an incubation temperature of 45 degrees C were used as the selective conditions for fecal coliforms, and KF streptococcal agar was used for the enumeration of enterococci. The method was more efficient than the standard most-probable-number method for fecal coliform enumeration and also allowed enumeration of the injured cells, which might have remained undetected when selective medium in the most-probable-number method was used. The repair detection method effectively recovered the injured portion of the population of enterococci capable of growing on KF streptococcal agar. The repair enumeration method was not suitable for coliforms in marine samples because associative marine bacteria mimicked coliforms in violet red bile agar plates incubated at 35 degrees C. The marine bacteria did not grow at 45 degrees C and therefore did not interfere with fecal coliform enumeration.  相似文献   

12.
The repair detection procedure of Speck et al. (Appl. Microbiol. 29:549-550, 1975) was adapted for the enumeration of coliforms, fecal coliforms, and enterococci in seafood and environmental samples. Samples were pour plated with Trypticase soy agar, followed by a 1- to 2-h incubation to effect repair; the plates were then overlaid with the selective medium and incubated. Violet red bile agar and an incubation temperature of 45 degrees C were used as the selective conditions for fecal coliforms, and KF streptococcal agar was used for the enumeration of enterococci. The method was more efficient than the standard most-probable-number method for fecal coliform enumeration and also allowed enumeration of the injured cells, which might have remained undetected when selective medium in the most-probable-number method was used. The repair detection method effectively recovered the injured portion of the population of enterococci capable of growing on KF streptococcal agar. The repair enumeration method was not suitable for coliforms in marine samples because associative marine bacteria mimicked coliforms in violet red bile agar plates incubated at 35 degrees C. The marine bacteria did not grow at 45 degrees C and therefore did not interfere with fecal coliform enumeration.  相似文献   

13.
Escherichia coli, total coliforms, fecal coliforms, and sulfite-reducing anaerobic spore formers from different polluted sites in a tropical environment were determined in order to test for their indication ability for fecal contamination. Quantification of E. coli contamination with Chromocult coliform agar proved to be efficient and feasible for determining fecal pollutions in the investigated area within 24 h. The other microbial parameters showed a lower ability to differentiate sites and cannot be recommended for monitoring fecal pollution in the studied tropical surface waters.  相似文献   

14.
Escherichia coli, total coliforms, fecal coliforms, and sulfite-reducing anaerobic spore formers from different polluted sites in a tropical environment were determined in order to test for their indication ability for fecal contamination. Quantification of E. coli contamination with Chromocult coliform agar proved to be efficient and feasible for determining fecal pollutions in the investigated area within 24 h. The other microbial parameters showed a lower ability to differentiate sites and cannot be recommended for monitoring fecal pollution in the studied tropical surface waters.  相似文献   

15.
Influence of Coliform Source on Evaluation of Membrane Filters   总被引:3,自引:3,他引:0       下载免费PDF全文
Four brands of membrane filters were examined for total and fecal coliform recovery performance by two experimental approaches. Using diluted EC broth cultures of water samples, Johns-Manville filters were superior to Sartorius filters for fecal coliform but equivalent for total coliform recovery. Using river water samples, Johns-Manville filters were superior to Sartorius filters for total coliform but equivalent for fecal coliform recovery. No differences were observed between Johns-Manville and Millipore or Millipore and Sartorius filters for total or fecal coliform recoveries using either approach, nor was any difference observed between Millipore and Gelman filters for fecal coliform recovery from river water samples. These results indicate that the source of the coliform bacteria has an important influence on the conclusions of membrane filter evaluation studies.  相似文献   

16.
A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole criterion used for designating positives, which can be determined either by increases in the electrical impedance ratio of inoculated medium, as compared to an uninoculated control using a Bactometer model 32, or by visual examination of inoculated medium for turbidity. In trials with 53 samples of unchlorinated sewage treatment plant effluent, fecal coliform counts by the single-step most-probable-number method, throughout a range of less than 10 to almost 10(7) fecal coliforms per 100 ml of effluent, were in excellent agreement with counts abtained by the standard most-probable-number procedure. Similar agreement was obtained in comparative trials with 31 chlorinated effluent samples from two sewage treatment plants. Overall, 87% of 452 positives were confirmed as containing fecal coliforms. The applicability of the single-step most-probable-number method to automated sewage treatment plant operations is discussed.  相似文献   

17.
A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole criterion used for designating positives, which can be determined either by increases in the electrical impedance ratio of inoculated medium, as compared to an uninoculated control using a Bactometer model 32, or by visual examination of inoculated medium for turbidity. In trials with 53 samples of unchlorinated sewage treatment plant effluent, fecal coliform counts by the single-step most-probable-number method, throughout a range of less than 10 to almost 10(7) fecal coliforms per 100 ml of effluent, were in excellent agreement with counts abtained by the standard most-probable-number procedure. Similar agreement was obtained in comparative trials with 31 chlorinated effluent samples from two sewage treatment plants. Overall, 87% of 452 positives were confirmed as containing fecal coliforms. The applicability of the single-step most-probable-number method to automated sewage treatment plant operations is discussed.  相似文献   

18.
The colorimetric beta-galactosidase assay is based upon the enzymatic hydrolysis of the substrate o-nitrophenyl-beta-D-galactoside (ONPG) by fecal coliforms. This technique provides an estimate of the fecal coliform concentration within 8 to 20 h. A 100-ml portion of test sample was passed through a 0.45 micrometer membrane filter. This filter was then incubated at 37 degrees C for 1 h in EC medium followed by the addition of filter-sterilized ONPG. The incubation was continued at 44.5 degrees C until a half-maximum absorbance (at 420 nm) was reached. The time between the start of incubation and the half-maximum absorbance was proportional to the concentration of fecal coliforms present. Escherichia coli (K-12) was used to measure the kinetics of substrate hydrolysis and the response time of different cell concentrations. High cell densities produced an immediate response, whereas 1 cell/ml will produce a response in less than 20 h. In field studies in which samples were taken from a range of grossly polluted streams to relatively clean lake water, a linear correlation between ONPG hydrolysis times and fecal coliform most-probable-number values was established. A total of 302 isolates randomly selected from positive ONPG-EC media, which were derived from 11 different habitats, were identified as E. coli (96.69 percent), Enterobacter cloacae (2.32 percent), Klebsiella pneumoniae (0.66 percent), and Citrobacter freundii (0.33 percent).  相似文献   

19.
The colorimetric beta-galactosidase assay is based upon the enzymatic hydrolysis of the substrate o-nitrophenyl-beta-D-galactoside (ONPG) by fecal coliforms. This technique provides an estimate of the fecal coliform concentration within 8 to 20 h. A 100-ml portion of test sample was passed through a 0.45 micrometer membrane filter. This filter was then incubated at 37 degrees C for 1 h in EC medium followed by the addition of filter-sterilized ONPG. The incubation was continued at 44.5 degrees C until a half-maximum absorbance (at 420 nm) was reached. The time between the start of incubation and the half-maximum absorbance was proportional to the concentration of fecal coliforms present. Escherichia coli (K-12) was used to measure the kinetics of substrate hydrolysis and the response time of different cell concentrations. High cell densities produced an immediate response, whereas 1 cell/ml will produce a response in less than 20 h. In field studies in which samples were taken from a range of grossly polluted streams to relatively clean lake water, a linear correlation between ONPG hydrolysis times and fecal coliform most-probable-number values was established. A total of 302 isolates randomly selected from positive ONPG-EC media, which were derived from 11 different habitats, were identified as E. coli (96.69 percent), Enterobacter cloacae (2.32 percent), Klebsiella pneumoniae (0.66 percent), and Citrobacter freundii (0.33 percent).  相似文献   

20.
Rural drinking water systems supplied by untreated groundwater were examined to determine whether coliform or heterotrophic plate count bacteria are capable of escaping entrapment on standard porosity (0.45-micron-pore-size) membrane filters. Filterable bacteria were present in 42% of the 24 groundwater sources examined by using nonselective media (R2A, full strength m-HPC, and 0.1x m-HPC agars). Pseudomonads were the most frequently identified group of filterable bacteria detected. Flavobacterium, Alcaligenes, Acinetobacter, and Achromobacter isolates were also identified. Total coliforms were not recovered from any of the 24 groundwater samples following filtration through 0.45-micron-pore-size membrane filters by using selective M-Endo LES agar or mT7 agar. In addition, none of the isolates identified from nonselective media were coliforms. Similarly, neither total coliforms nor specifically Escherichia coli were detected in these filtrates when Colilert P/A medium was used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号