首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A change in the elasticity of mouse zona pellucida was quantitatively evaluated during oocyte maturation, fertilization and early embryo development. Young's modulus of zona pellucida of germinal vesicle (GV), metaphase-II (MII), pronuclear (PN), 2cell, 4cell, 8cell, morulae (M) and early blastocyst (EB) stages was measured using a micro tactile sensor (MTS) and a chamber exclusively designed for the measurement. The MTS has very high sensitivity and a deformation of only 5 microm was sufficient to calculate the Young's modulus and the oocyte/embryo maintained its original spherical shape during the measurement. The Young's modulus of GV, MII, PN, 2cell, 4cell, 8cell, M and EB was 22.8+/-10.4 kPa (n=30), 8.26+/-5.22 kPa (n=74), 22.3+/-10.5 kPa (n=66), 13.8+/-3.54 kPa (n=41), 12.6+/-3.34 kPa (n=19), 5.97+/-4.97 kPa (n=6), 1.88+/-1.34 kPa (n=8) and 3.39+/-1.86 kPa (n=4), respectively. Experimental results clearly demonstrated that the mouse zona pellucida hardened following fertilization. Interestingly, once the zona pellucida hardened at the PN stage, it gradually softened as the embryo developed (i.e. it was found that the zona hardening is a transient phenomenon). Furthermore, the zona pellucida of the GV oocyte was as hard as that of the PN embryo and became soft as it matured to the MII stage. In addition, the safety of the MTS measurement for oocytes and embryos was discussed both theoretically and experimentally.  相似文献   

2.
Piezoelectric quartz crystal impedance (QCI) technique was used for monitoring the Cu(2+)-induced precipitation of bovine serum albumin onto the gold electrode. The critical precipitate concentration of Cu(2+) reflected by the significant decrease in the resonant frequency was estimated to be 9.98 x 10(-5) mol x l(-1), and the saturated adherence of the precipitate on the electrode occurred when the Cu(2+) concentration was greater than 9.79x10(-3) mol x l(-1). The frequency shift in air was about 85.5% of that in liquid, and the Deltaf(0)/DeltaR(1) ratio found in solution was 82.67 Hz Omega(-1), suggesting that the frequency response was predominated by the mass change due to precipitate adherence to the electrode surface. The response of the resonant frequency was analyzed using an equation Deltaf=a(0) + a(1) e(-t/tau(1)) + a(2) e(-t/tau(2)). The relationship between the total a(0) values and the Cu(2+) concentration was discussed.  相似文献   

3.
The lack of standardization in experimental protocols for unconfined compression tests of intervertebral discs (IVD) tissues is a major issue in the quantification of their mechanical properties. Our hypothesis is that the experimental protocols influence the mechanical properties of both annulus fibrosus and nucleus pulposus. IVD extracted from bovine tails were tested in unconfined compression stress-relaxation experiments according to six different protocols, where for each protocol, the initial swelling of the samples and the applied preload were different. The Young's modulus was calculated from a viscoelastic model, and the permeability from a linear biphasic poroviscoelastic model. Important differences were observed in the prediction of the mechanical properties of the IVD according to the initial experimental conditions, in agreement with our hypothesis. The protocol including an initial swelling, a 5% strain preload, and a 5% strain ramp is the most relevant protocol to test the annulus fibrosus in unconfined compression, and provides a permeability of 5.0 ± 4.2e(-14)m(4)/N[middle dot]s and a Young's modulus of 7.6 ± 4.7 kPa. The protocol with semi confined swelling and a 5% strain ramp is the most relevant protocol for the nucleus pulposus and provides a permeability of 10.7 ± 3.1 e(-14)m(4)/N[middle dot]s and a Young's modulus of 6.0 ± 2.5 kPa.  相似文献   

4.
The Ca(2+)-induced effect on the nanomechanical properties of vesicles prepared at a different ratio of dipalmitoylphosphatidylcholine (DPPC)/sulfatide was studied using atomic force microscope (AFM) on a mica surface. Vesicles were prepared by extrusion and adsorbed on the mica surface. The forces, measured between an AFM tip and the vesicle, showed that the breakthrough of the tip into the vesicles occurred two times. Force data prior to the first breakthrough were fitted well with the Hertzian model to estimate Young's modulus and bending modulus of the vesicles. Sulfatide incorporation led to a decrease of around 90% in Young's modulus and bending modulus of the vesicles due to the hydration of the headgroups, while the addition of Ca(2+) induced dehydration to recover the properties. The change of the physical properties seems to be attributed to the headgroup packing order of the vesicles, which is determined by the interference with the hydration shell.  相似文献   

5.
Ionic Polymer-Metal Composite (IPMC) can work as an actuator by applying a few voltages.A thick IPMC actuator,whereNafion-117 membrane was synthesized with polypyrrole/alumina composite filler,was analyzed to verify the equivalent beamand equivalent bimorph beam models.The blocking force and tip displacement of the IPMC actuator were measured with a DCpower supply and Young’s modulus of the IPMC strip was measured by bending and tensile tests respectively.The calculatedmaximum tip displacement and the Young’s modulus by the equivalent beam model were almost identical to the correspondingmeasured data.Finite element analysis with thermal analogy technique was utilized in the equivalent bimorph beam model tonumerically reproduce the force-displacement relationship of the IPMC actuator.The results by the equivalent bimorph beammodel agreed well with the force-displacement relationship acquired by the measured data.It is confirmed that the equivalentbeam and equivalent bimorph beam models are practically and effectively suitable for predicting the tip displacement,blockingforce and Young’s modulus of IPMC actuators with different thickness and different composite of ionic polymer membrane.  相似文献   

6.
Unconfined creep compression of chondrocytes   总被引:7,自引:0,他引:7  
The study of single cell mechanics offers a valuable tool for understanding cellular milieus. Specific knowledge of chondrocyte biomechanics could lead to elucidation of disease etiologies and the biomechanical factors most critical to stimulating regenerative processes in articular cartilage. Recent studies in our laboratory have suggested that it may be acceptable to approximate the shape of a single chondrocyte as a disc. This geometry is easily utilized for generating models of unconfined compression. In this study, three continuum mechanics models of increasing complexity were formulated and used to fit unconfined compression creep data. Creep curves were obtained from middle/deep zone chondrocytes (n = 15) and separately fit using the three continuum models. The linear elastic solid model yielded a Young's modulus of 2.55+/-0.85 kPa. The viscoelastic model (adapted from the Kelvin model) generated an instantaneous modulus of 2.47+/-0.85 kPa, a relaxed modulus of 1.48+/-0.35 kPa, and an apparent viscosity of 1.92+/-1.80 kPa-s. Finally, a linear biphasic model produced an aggregate modulus of 2.58+/-0.87 kPa, a permeability of 2.57 x 10(-12)+/-3.09 m(4)/N-s, and a Poisson's ratio of 0.069+/-0.021. The results of this study demonstrate that similar values for the cell modulus can be obtained from three models of increasing complexity. The elastic model provides an easy method for determining the cell modulus, however, the viscoelastic and biphasic models generate additional material properties that are important for characterizing the transient response of compressed chondrocytes.  相似文献   

7.
Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 2.48 mm2 were fabricated. Antibody specific to Bacillus anthracis (BA, Sterne strain 7702) spores was immobilized on PEMC sensors, and exposed to spores (300 to 3x10(6) spores/mL). The resonant frequency decreased at a rate proportional to the spore concentration and reached a steady state frequency change of 5+/-5 Hz (n=3), 92+/-7 Hz (n=3), 500+/-10 Hz (n=3), 1030+/-10 Hz (n=2), and 2696+/-6 Hz (n=2) corresponding to 0, 3x10(2), 3x10(3), 3x10(4), and 3x10(6) spores/mL, respectively. The reduction in resonant frequency is proportional to the change in cantilever mass, and thus the observed changes are due to the attachment of spores on the sensor surface. Selectivity of the antibody-functionalized sensor was determined with samples of BA (3x10(6)/mL) mixed with Bacillus thuringiensis (BT; 1.5x10(9)/mL) in various volume ratios that yielded BA:BT ratios of 1:0, 1:125, 1:250, 1:500 and 0:1. The corresponding resonance frequency decreases were, respectively, 2345, 1980, 1310, 704 and 10 Hz. Sample containing 100% BT spores (1.5x10(9)/mL and no BA) gave a steady state frequency decrease of 10 Hz, which is within noise level of the sensor, indicating excellent selectivity. The observed binding rate constant for the pure BA and BT-containing samples ranged from 0.105 to 0.043 min-1 in the spore concentration range 300 to 3x10(6)/mL. These results show that detection of B. anthracis spore at a very low concentration (300 spores/mL) and with high selectivity in presence of another Bacillus spore (BT) can be accomplished using piezoelectric-excited millimeter-sized cantilever sensors.  相似文献   

8.
Atomic force microscopy was used to investigate the surface morphology and transverse stiffness of myofibrils from Drosophila indirect flight muscle exposed to different physiologic solutions. I- and A-bands were clearly observed, and thick filaments were resolved along the periphery of the myofibril. Interfilament spacings correlated well with estimates from previous x-ray diffraction studies. Transverse stiffness was measured by using a blunt tip to indent a small section of the myofibrillar surface in the region of myofilament overlap. At 10 nm indention, the effective transverse stiffness (K( perpendicular)) of myofibrils in rigor solution (ATP-free, pCa 4.5) was 10.3 +/- 5.0 pN nm(-1) (mean +/- SEM, n = 8); in activating solution (pCa 4.5), 5.9 +/- 3.1 pN nm(-1); and in relaxing solution (pCa 8), 4.4 +/- 2.0 pN nm(-1). The apparent transverse Young's modulus (E( perpendicular)) was 94 +/- 41 kPa in the rigor state and 40 +/- 17 kPa in the relaxed state. The value of E( perpendicular) for calcium-activated myofibrils (55 +/- 29 kPa) was approximately a tenth that of Young's modulus in the longitudinal direction, a difference that at least partly reflects the transverse flexibility of the myosin molecule.  相似文献   

9.
In articular cartilage, chondrocytes are surrounded by a pericellular matrix (PCM), which together with the chondrocyte have been termed the "chondron." While the precise function of the PCM is not know there has been considerable speculation that it plays a role in regulating the biomechanical environment of the chondrocyte. In this study, we measured the Young's modulus of the PCM from normal and osteoarthritic cartilage using the micropipette aspiration technique, coupled with a newly developed axisymmetric elastic layered half-space model of the experimental configuration. Viable, intact chondrons were extracted from human articular cartilage using a new microaspiration-based isolation technique. In normal cartilage, the Young's modulus of the PCM was similar in chondrons isolated from the surface zone (68.9 +/- 18.9 kPa) as compared to the middle and deep layers (62.0 +/- 30.5 kPa). However, the mean Young's modulus of the PCM (pooled for the two zones) was significantly decreased in osteoarthritic cartilage (66.5 +/- 23.3 kPa versus 41.3 +/- 21.1 kPa, p < 0.001). In combination with previous theoretical models of cell-matrix interactions in cartilage, these findings suggest that the PCM has an important influence on the stress-strain environment of the chondrocyte that potentially varies with depth from the cartilage surface. Furthermore, the significant loss of PCM stiffness that was observed in osteoarthritic cartilage may affect the magnitude and distribution of biomechanical signals perceived by the chondrocytes.  相似文献   

10.
The expansive growth and differentiation potential of human embryonic stem cells (hESCs) make them a promising source of cells for regenerative medicine. However, this promise is off set by the propensity for spontaneous or uncontrolled differentiation to result in heterogeneous cell populations. Cell elasticity has recently been shown to characterize particular cell phenotypes, with undifferentiated and differentiated cells sometimes showing significant differences in their elasticities. In this study, we determined the Young's modulus of hESCs by atomic force microscopy using a pyramidal tip. Using this method we are able to take point measurements of elasticity at multiple locations on a single cell, allowing local variations due to cell structure to be identified. We found considerable differences in the elasticity of the analyzed hESCs, reflected by a broad range of Young's modulus (0.05-10 kPa). This surprisingly high variation suggests that elasticity could serve as the basis of a simple and efficient large scale purification/separation technique to discriminate subpopulations of hESCs.  相似文献   

11.
Acoustic microscopy (30-60 microm resolution) and nanoindentation (1-5 microm resolution) are techniques that can be used to evaluate the elastic properties of human bone at a microstructural level. The goals of the current study were (1) to measure and compare the Young's moduli of trabecular and cortical bone tissues from a common human donor, and (2) to compare the Young's moduli of bone tissue measured using acoustic microscopy to those measured using nanoindentation. The Young's modulus of cortical bone in the longitudinal direction was about 40% greater than (p<0.01) the Young's modulus in the transverse direction. The Young's modulus of trabecular bone tissue was slightly higher than the transverse Young's modulus of cortical bone, but substantially lower than the longitudinal Young's modulus of cortical bone. These findings were consistent for both measurement methods and suggest that elasticity of trabecular tissue is within the range of that of cortical bone tissue. The calculation of Young's modulus using nanoindentation assumes that the material is elastically isotropic. The current results, i.e., the average anisotropy ratio (E(L)/E(T)) for cortical bone determined by nanoindentation was similar to that determined by the acoustic microscope, suggest that this assumption does not limit nanoindentation as a technique for measurement of Young's modulus in anisotropic bone.  相似文献   

12.
A quartz crystal microbalance (QCM) cell biosensor utilizing living endothelial cells (ECs) or human breast cancer cells (MCF-7) adhering to the gold QCM surface was used to study the relative contributions of the cells and their underlying extracellular matrix (ECM) to the measured QCM Deltaf and DeltaR shifts. The ECM represents a natural biomaterial that is synthesized by the cells to enable their attachment to surfaces. We followed the detachment of the ECs or MCF-7 cells from their ECM using a nonproteolytic method and were able to apportion the total frequency, Deltaf, decrease of the biosensor into contributions from cell attachment and from the intact underlying ECM. We also demonstrated that the Deltaf shift remaining after EC removal corresponds to ECM as determined by light microscopic visualization of the stained protein. During the process of cell detachment, we observed a novel transient increase in viscoelastic behavior expressed as a transient increase in the motional resistance, DeltaR, parameter. Then we showed via a simulation experiment using ECs stained with fluorescent rhodamine-labeled phalloidin, an actin stain, that the transient viscoelastic increase correlated with cellular stress exhibited by the cells during removal with ethylene glycol bis(2-aminoethyl ether)-N,N,N',N'- tetraacetic acid. Prior to cells lifting from their ECM, the attached ECs rearrange their actin microfilaments first into peripheral stress fibers and second into internal aggregates, to maintain cell-cell connectivity, retain their spread morphology, and attempt to adhere more tightly to their underlying ECM. The decrease in DeltaR following its transient rise corresponds to cells finally losing their attachment focal points and lifting from the ECM. We also characterized the normalized f shifts, -Delta(Deltaf)(ECM)/attached cell and -Delta(Deltaf)(cells)/attached cell, as a function of varying the number of adherent cells. Finally, we demonstrate that the underlying native ECM biomaterial, from which all cells have been removed, does not exhibit any significant level of energy dissipation, in contrast to the cells when they are attached to the ECM.  相似文献   

13.
The pericellular matrix (PCM) is a narrow region of cartilaginous tissue that surrounds chondrocytes in articular cartilage. Previous modeling studies indicate that the mechanical properties of the PCM relative to those of the extracellular matrix (ECM) can significantly affect the stress-strain, fluid flow, and physicochemical environments of the chondrocyte, suggesting that the PCM plays a biomechanical role in articular cartilage. The goals of this study were to measure the mechanical properties of the PCM using micropipette aspiration coupled with a linear biphasic finite element model, and to determine the alterations in the mechanical properties of the PCM with osteoarthritis (OA). Using a recently developed isolation technique, chondrons (the chondrocyte and its PCM) were mechanically extracted from non-degenerate and osteoarthritic human cartilage. The transient mechanical behavior of the PCM was well-described by a biphasic model, suggesting that the viscoelastic response of the PCM is attributable to flow-dependent effects, similar to that of the ECM. With OA, the mean Young's modulus of the PCM was significantly decreased (38.7+/-16.2 kPa vs. 23.5+/-12.9 kPa, p < 0.001), and the permeability was significantly elevated (4.19+/-3.78 x10(-17) m(4)/Ns vs. 10.2+/-9.38 x 10(-17) m(4)/Ns, p < 0.01). The Poisson's ratio was similar for both non-degenerate and OA PCM (0.044+/-0.063 vs. 0.030+/-0.068, p > 0.6). These findings suggest that the PCM may undergo degenerative processes with OA, similar to those occurring in the ECM. In combination with previous theoretical models of cell-matrix interactions in cartilage, our findings suggest that changes in the properties of the PCM with OA may have an important influence on the biomechanical environment of the chondrocyte.  相似文献   

14.
Laparoscopic surgery requires inflation of the abdominal cavity and this offers a unique opportunity to measure the mechanical properties of the living abdominal wall. We used a motion analysis system to study the abdominal wall motion of 18 patients undergoing laparoscopic surgery, and found that the mean Young's modulus was 27.7+/-4.5 and 21.0+/-3.7 kPa for male and female, respectively. During inflation, the abdominal wall changed from a cylinder to a dome shape. The average expansion in the abdominal wall surface was 20%, and a working space of 1.27 x 10(-3)m(3) was created by expansion, reshaping of the abdominal wall and diaphragmatic movement. For the first time, the elasticity of human abdominal wall was obtained from the patients undergoing laparoscopic surgery, and a 3D simulation model of human abdominal wall has been developed to analyse the motion pattern in laparoscopic surgery. Based on this study, a mechanical abdominal wall lift and a surgical simulator for safe/ergonomic port placements are under development.  相似文献   

15.
Mechanical properties of polyelectrolyte multilayer films were studied by nanoindentation using the atomic force microscope (AFM). Force-distance measurements using colloidal probe tips were systematically obtained for supported films of poly(L-lysine) and hyaluronan that are suited to bio-application. Both native and covalently cross-linked films were studied as a function of increasing layer number, which increases film thickness. The effective Young's modulus perpendicular to the film, Eperpendicular, was determined to be a function of film thickness, cross-linking, and sample age. Thick PEM films exhibited a lower Eperpendicular than thinner PEM, whereas the Young's modulus of cross-linked films was more than 10-fold larger than native films. Moduli range from approximately 20 kPa for native films up to approximately 800 kPa for cross-linked ones. Young's moduli increased slightly with sample age, plateauing after approximately 4 weeks. Spreading of smooth muscle cells on these substrates with pre-attached collagen proved to be highly dependent on film rigidity with stiffer films giving greater cell spreading.  相似文献   

16.
A viscoelastic nanoindentation technique was developed to measure both in-plane and through-thickness viscoelastic properties of human tympanic membrane (TM). For measurement of in-plane Young's relaxation modulus, the TM sample was clamped on a circular hole and a nanoindenter tip was used to apply a concentrated force at the center of the TM sample. In this setup, the resistance to nanoindentation displacement can be considered due primarily to the in-plane stiffness. The load-displacement curve obtained was used along with finite element analysis to determine the in-plane viscoelastic properties of TM. For measurements of Young's relaxation modulus in the through-thickness (out-of-plane) direction, the TM sample was placed on a relatively rigid solid substrate and nanoindentation was made on the sample surface. In this latter setup, the resistance to nanoindentation displacement arises primarily due to out-of-plane stiffness. The load-displacement curve obtained in this manner was used to determine the out-of-plane relaxation modulus using the method appropriate for viscoelastic materials. From our sample tests, we obtained the steady-state values for in-plane moduli as approximately 17.4 MPa and approximately 19.0 MPa for posterior and anterior portions of TM samples, respectively, and the value for through-thickness modulus as approximately 6.0 MPa for both posterior and anterior TM samples. Using this technique, the local out-of-plane viscoelastic modulus can be determined for different locations over the entire TM, and the in-plane properties can be determined for different quadrants of the TM.  相似文献   

17.
Nanocellulose/montmorillonite (MTM) composite films were prepared from 2,2,6,6-tetramethylpiperidine-1-oxyl radical (TEMPO)-oxidized cellulose nanofibrils (TOCNs) with an aspect ratio of >200 dispersed in water with MTM nanoplatelets. The composite films were transparent and flexible and showed ultrahigh mechanical and oxygen barrier properties through the nanolayered structures, which were formed by compositing the anionic MTM nanoplatelet filler in anionic and highly crystalline TOCN matrix. A composite film with 5% MTM content had Young's modulus 18 GPa, tensile strength 509 MPa, work of fracture of 25.6 MJ m(-3), and oxygen permeability 0.006 mL μm m(-2) day(-1) kPa(-1) at 0% relative humidity, respectively, despite having a low density of 1.99 g cm(-3). As the MTM content in the TOCN/MTM composites was increased to 50%, light transmittance, tensile strength, and elongation at break decreased, while Young's modulus was almost unchanged and oxygen barrier property was further improved to 0.0008 mL μm m(-2) day(-1) kPa(-1).  相似文献   

18.
Due to its avascular nature, articular cartilage exhibits a very limited capacity to regenerate and to repair. Although much of the tissue-engineered cartilage in existence has been successful in mimicking the morphological and biochemical appearance of hyaline cartilage, it is generally mechanically inferior to the natural tissue. In this study, we tested the hypothesis that the application of dynamic deformational loading at physiological strain levels enhances chondrocyte matrix elaboration in cell-seeded agarose scaffolds to produce a more functional engineered tissue construct than in free swelling controls. A custom-designed bioreactor was used to load cell-seeded agarose disks dynamically in unconfined compression with a peak-to-peak compressive strain amplitude of 10 percent, at a frequency of 1 Hz, 3 x (1 hour on, 1 hour off)/day, 5 days/week for 4 weeks. Results demonstrated that dynamically loaded disks yielded a sixfold increase in the equilibrium aggregate modulus over free swelling controls after 28 days of loading (100 +/- 16 kPa versus 15 +/- 8 kPa, p < 0.0001). This represented a 21-fold increase over the equilibrium modulus of day 0 (4.8 +/- 2.3 kPa). Sulfated glycosaminoglycan content and hydroxyproline content was also found to be greater in dynamically loaded disks compared to free swelling controls at day 21 (p < 0.0001 and p = 0.002, respectively).  相似文献   

19.
基于原子力显微镜测量内耳螺旋器的弹性特征   总被引:1,自引:0,他引:1  
应用原子力显微镜分析内耳螺旋器(Corti器)不同部位的弹性特征。采用豚鼠内耳基底膜底回新鲜标本,用原子力显微镜在液相接触式测量,获得不同部位力曲线。经计算,对应Corti器相当于Hensen细胞、外毛细胞、柱细胞、内毛细胞、内指细胞、盖膜的部位及基底膜底面局部,其杨氏模量均值分别为46±1.7、59±0.9、250±31、140±2.8、430±29.9、210±7.2和230±8.8 kPa。结果表明,基底膜径向排列的组织结构不同,杨氏模量存在明显差异,在整块基底膜标本上测量Corti器各结构的杨氏模量能更准确地反映它们在生理状态下的弹性特征。  相似文献   

20.
Atomic force microscopy (AFM) has been used to study the micromechanical properties of biological systems. Its unique ability to function both as an imaging device and force sensor with nanometer resolution in both gaseous and liquid environments has meant that AFM has provided unique insights into the mechanical behaviour of tissues, cells and single molecules. As a surface scanning device, AFM can map properties such as adhesion and the Young's modulus of surfaces. As a force sensor and nanoindentor AFM can directly measure properties such as the Young's modulus of surfaces or the binding forces of cells. As a stress-strain gauge AFM can study the stretching of single molecules or fibres and as a nanomanipulator it can dissect biological particles such as viruses or DNA strands. The present paper reviews key research that has demonstrated the versatility of AFM and how it can be exploited to study the micromechanical behaviour of biological materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号