首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Gated detection is often used in time-domain measurements of long-lived fluorophores for suppression of interfering short-lived autofluorescence. However, no direct method has been available for gated detection and background suppression when using frequency-domain fluorometry. We describe a direct method for real-time suppression of autofluorescence in frequency-domain fluorometry. The method uses a gated detector and the sample is excited by a pulsed train. The detector is gated on following each excitation pulse after a suitable time delay for decay of the prompt autofluorescence. Under the same experimental conditions a detectable reference signal is obtained by using a long lifetime standard with a known decay time. Because the sample and reference signals are measured under identical excitation, gating and instrumental conditions, the data can be analyzed as usual for frequency-domain data without further processing. We show by simulations that this method can be used to resolve single and multiexponential decays in the presence of short lifetime autofluorescence.  相似文献   

2.
Background fluorescence is a major concern in time-resolved microfluorimetry studies of biological samples. A general method for subtraction of an arbitrary background signal in measurements of lifetime and anisotropy decay by multiharmonic Fourier transform spectroscopy is presented. Multifrequency phase and modulation values are measured in parallel by transformation of digitized time-domain waveforms into the frequency domain. For subtraction of background, time-domain waveforms are acquired for emission and reference photomultipliers for sample (e.g., cell containing fluorophore) and blank (e.g., unlabeled cell). Time-domain waveforms obtained in a series of measurements (e.g., sample and blank for parallel and perpendicular orientations of an emission polarizer) are time-justified by least-squares fitting of reference channel waveforms or by phase comparison of the first Fourier harmonics of the reference channel. Background is then subtracted directly in the time domain, and the subtracted waveform is Fourier transformed to the frequency domain for analysis of lifetime or anisotropy decay. This approach yielded excellent background correction over a wide range of background intensities and decay profiles. The method was tested in cuvette fluorimetry with fluorescein and acridine orange and in fluorescence microscopy with living MDCK cells loaded with the pH indicator BCECF. Sample lifetimes and rotational parameters could be recovered accurately with greater than 50% of the signal arising from background. These results establish a direct and practical approach to subtraction of background in complex biological and chemical samples studied by frequency-domain fluorimetry.  相似文献   

3.
Investigation of protein-protein associations is important in understanding structure and function relationships in living cells. Using Förster-type resonance energy transfer between donor and acceptor labeled monoclonal antibodies we can assess the cell surface topology of membrane proteins against which the antibodies were raised. In our current work we elaborated a quantitative image microscopic technique based on the measurement of fluorescence intensities to calculate the energy transfer efficiency on a pixel-by-pixel basis. We made use of the broad excitation and emission spectrum of cellular autofluorescence for background correction of images. In addition to the reference autofluorescence images (UV background) we recorded three fluorescent images (donor, acceptor and energy transfer signal) of donor-acceptor double labeled samples, and corrected for spectral spillage of the directly excited donor and acceptor fluorescence into the energy transfer image. After careful image registration we were able to calculate the energy transfer efficiency on a pixel-by-pixel basis. In this paper, we also present a critical comparison between results obtained with this method and other approaches (photobleaching and flow cytometric energy transfer measurements).  相似文献   

4.
A method has been developed for reducing the intrinsic autofluorescence background component in cells labeled with fluorescent antibodies, thus permitting low levels of antibody-binding on highly autofluorescent cells to be quantified. The method is based on the broad autofluorescent excitation spectra compared to the well-defined spectra of the fluorescent label. Two laser wavelengths were used, one optimally to excite the fluorescent label plus autofluorescence and the second to excite only the autofluorescence. Two fluorescence measurements were made in the same wavelength region and the signals were subtracted on a cell-by-cell basis using a difference amplifier to zero the autofluorescence and amplify the signal from the fluorescent label. Test results on unlabeled autofluorescent macrophages showed that the autofluorescence component was reduced by balancing the signal inputs to the difference amplifier. When labeled macrophages were analyzed, the autofluorescence was reduced and the fluorescent-labeled antibody-binding component was amplified. The method was also able to resolve labeled lymphocytes from unlabeled autofluorescent macrophages.  相似文献   

5.
Polarized fluorescence depletion (PFD) methods (Yoshida, T. M. and B. G. Barisas. Biophys. J. 1986. 50:41-53) are approximately 10(3)-10(4) fold more sensitive than other techniques for measuring protein rotational motions in cell membranes and other viscous environments. Proteins labeled with fluorophores having a high quantum yield for triplet formation are examined anaerobically in a fluorescence microscope. In time domain PFD experiments a several-microsecond pulse of linearly polarized light produces an orientationally-asymmetric depletion of ground state fluorescence in the sample. Monitoring the decay of ground state depletion with a probe beam alternatively polarized, parallel, and perpendicular to the depletion pulse permits the triplet lifetime and rotational correlation time to be resolved and evaluated. We have now explored fluorescence depletion methods in the frequency domain to see whether such measurements could provide simpler and more efficient routine measurements of protein rotational relaxation than previous time domain PFD methods. An acousto-optic modulator (AOM) modulates the intensity of a 514.5 nm argon ion laser beam and a Pockels cell (PC) rotates its plane of polarization. These devices are driven by sinusoidal or square waves in fixed frequency relation, and rigidly phase locked, one to another. The fluorescence emitted from a sample then contains various overtones and combinations of the AOM and PC frequencies. The magnitude and phase of individual fluorescence signal frequencies are measured by a lock-in amplifier using a reference also phase-locked to both the AOM and PC. Specific frequencies permit evaluation of the rotational correlation time of the macromolecule and of the fluorophore triplet state lifetime, respectively. Measurement of bovine serum albumin rotation in glycerol solutions by this method is described.  相似文献   

6.
For many cell types, cellular autofluorescence in the 500-600 nm spectral region can result in a significant background signal for measurements of weakly fluorescent probes. Measurements of fluorescence intensity and spectra of a variety of cell types and assays of neuronal homogenates are presented to demonstrate that this autofluorescence is most likely due to endogenous flavoproteins.  相似文献   

7.
An assay was developed for the characterization of protein kinase inhibitors in lysates of mammalian cells based on the measurement of FRET between overexpressed red fluorescent protein (TagRFP)-fused protein kinases (PKs) and luminophore-labeled small-molecule inhibitors (ARC-Photo probes). Two types of the assay, one using TagRFP as the photoluminescence donor together with ARC-Photo probes containing a red fluorophore dye as acceptor, and the other using TagRFP as the acceptor fluorophore in combination with a terbium cryptate-based long-lifetime photoluminescence donor, were used for FRET-based measurements in lysates of the cells overexpressing TagRFP-fused PKs. The second variant of the assay enabled the performance of the measurements under time-resolved conditions that led to substantially higher values of the signal/background ratio and further improved the reliability of the assay.  相似文献   

8.

Background

The autofluorescence background of biological samples impedes the detection of single molecules when imaging. The most common method of reducing the background is to use evanescent field excitation, which is incompatible with imaging beyond the surface of biological samples. An alternative would be to use probes that can be excited in the near infra-red region of the spectrum, where autofluorescence is low. Such probes could also increase the number of labels that can be imaged in multicolour single molecule microscopes. Despite being widely used in ensemble imaging, there is a currently a shortage of information available for selecting appropriate commercial near infra-red dyes for single molecule work. It is therefore important to characterise available near infra-red dyes relevant to multicolour single molecule imaging.

Methodology/Principal Findings

A range of commercially available near infra-red dyes compatible with multi-colour imaging was screened to find the brightest and most photostable candidates. Image series of immobilised samples of the brightest dyes (Alexa 700, IRDye 700DX, Alexa 790 and IRDye 800CW) were analysed to obtain the mean intensity of single dye molecules, their photobleaching rates and long period blinking kinetics. Using the optimum dye pair, we have demonstrated for the first time widefield, multi-colour, near infra-red single molecule imaging using a supercontinuum light source in MCF-7 cells.

Conclusions/Significance

We have demonstrated that near infra-red dyes can be used to avoid autofluorescence background in samples where restricting the illumination volume of visible light fails or is inappropriate. We have also shown that supercontinuum sources are suited to single molecule multicolour imaging throughout the 470–1000 nm range. Our measurements of near infra-red dye properties will enable others to select optimal dyes for single molecule imaging.  相似文献   

9.
Attainable levels of signal-to-background ratio (SBR) in Raman spectroscopy of biological samples is limited by the presence of endogenous fluorophores. It is customary to remove the ubiquitous fluorescence background using postacquisition data processing. However, new approaches are needed to reduce background contributions and maximize the fraction of the sensor dynamical range occupied by Raman photons. Time-resolved detection using pulsed lasers and time-gated measurements can be used to address the signal-to-background problem in biological samples by limiting light detection to nonresonant interaction phenomena with relaxation time scales occurring on sub-nanosecond time scales, thereby excluding contributions from resonant phenomena such as fluorescence. A time-gated Fourier-transform spectrometer was assembled using a commercially available interferometer, a single channel single-photon avalanche diode and time tagging electronics. A time gate of 300 ps increased the signal-to-background-ratio of the 1440 cm?1 Raman band from 36% to 69% in an olive oil sample hereby demonstrating the potential of this approach for autofluorescence suppression.   相似文献   

10.
针刺与脉象在传统中医观念中是紧紧联系在一起的。本课题针对这一传统理论,建立一个基于频域上的模拟函数得出的脉象频谱数学模型,并用此模型来检验针刺前后脉象发生的结构上的变化。由量化的脉象信号得出的大量统计数据显示,脉象在频域上的包络线呈指数衰减的趋势,并且针刺后其拟合率更高。由统计结果得出,脉象在频域上的衰减率明显增大。同时,从数学上说明了其衰减率的增大等价于脉象在时域上的降中峡、重搏波,及低频涨落程度的变化,也对时域上的脉象作了新的数学模型的模拟。本项研究证实了针刺对脉象具有调整作用。  相似文献   

11.
Fluorescent lanthanide chelates with long decay times allow the suppression of the fast decaying autofluorescence in biological specimens. This property makes lanthanide chelates attractive as labels for fluorescence microscopy. As a consequence of the suppression of the background fluorescence the sensitivity can be increased. We modified a standard epifluorescence microscope for time-resolved fluorescence imaging by adding a pulsed light source and a chopper in the narrow aperture plane. A cooled CCD-camera was used for detection and the images were digitally processed. A fluorescent europium chelate was conjugated to antisera and to streptavidin. These conjugates were used for the localization of tumor associated antigen C242 in the malignant mucosa of human colon, for the localization of type II collagen mRNA in developing human cartilaginary growth plates, and for the detection of HPV type specific gene sequences in the squamous epithelium of human cervix. The specific slowly decaying fluorescence of the europium label could be effectively separated from the fast decaying background fluorescence. It was possible to use the europium label at the cell and tissue level and the autofluorescence was effectively suppressed in in situ hybridization and immunohistochemical reactions in both frozen and formaldehyde-fixed, wax-embedded specimens.  相似文献   

12.
NMR-based metabolomics requires robust automated methodologies, and the accuracy of NMR-based metabolomics data is greatly influenced by the reproducibility of data acquisition and processing methods. Effective water resonance signal suppression and reproducible spectral phasing and baseline traces across series of related samples are crucial for statistical analysis. We assess robustness, repeatability, sensitivity, selectivity, and practicality of commonly used solvent peak suppression methods in the NMR analysis of biofluids with respect to the automated processing of the NMR spectra and the impact of pulse sequence and data processing methods on the sensitivity of pattern recognition and statistical analysis of the metabolite profiles. We introduce two modifications to the excitation sculpting pulse sequence whereby the excitation solvent suppression pulse cascade is preceded by low-power water resonance presaturation pulses during the relaxation delay. Our analysis indicates that combining water presaturation with excitation sculpting water suppression delivers the most reproducible and information-rich NMR spectra of biofluids.  相似文献   

13.
An engineered Tn10-encoded Tet repressor, bearing a single Trp residue at position 43, in the putative alpha-helix-turn-alpha-helix motif of the operator binding domain, was studied by time-resolved fluorescence and anisotropy. Fluorescence intensity decay data suggested the existence of two classes of Trp-43, defined by different lifetimes. Analysis of anisotropy data were consistent with a model in which each class was defined by a different lifetime, rotational correlation time, and fluorescence emission maximum. The long-lifetime class had a red-shifted spectrum, similar to that of tryptophan zwitterion in water, and a short rotational correlation time. In contrast, the spectrum of the short-lifetime class was blue-shifted 10 nm compared to that of the long-lifetime class. Its correlation time was similar to that of the protein, which showed that Trp in this class was entirely constrained. Trp in this latter class could not be quenched by iodide, whereas most of the long-lifetime class was easily accessible. Presence of disruptive agents, such as 1 M GuCl or 3 M KCl, did not alter markedly the lifetimes but increased the weight of the short-lifetime component. In the same time, the rotational correlation time of this component was dramatically reduced. Taken together, our data suggest that the long-lifetime class could correspond to the tryptophan residues exposed to solvent whereas the short-lifetime class would correspond to the tryptophan residues embedded inside the hydrophobic core holding the helix-turn-helix motif. Destabilization of hydrophobic interactions would lead to an increase in the weight of the latter class for entropic reasons. Analysis of the fluorescence parameters of Trp-43 could provide structural information on the operator binding domain of Tet repressor.  相似文献   

14.
Spring-born crossbred ewe lambs were raised in a natural photoperiod and saline (N = 6) or naloxone (1 mg/kg) in saline (N = 6) was injected (i.m.) every 2 h for 6 h at 5, 10 and 15 weeks of age and for 8 h at 20, 25 and 30 weeks of age. Blood samples were taken every 12 min during treatment periods. Naloxone had no effect on time to first oestrus (controls 235 +/- 6 days, naloxone 242 +/- 7 days). Mean serum LH concentrations and LH pulse frequency were elevated by naloxone in ewe lambs at 20, 25, and 30 weeks of age (P less than 0.05). The only FSH response to naloxone was a depression of mean serum concentrations at 30 weeks of age (P less than 0.05). LH pulse amplitude was elevated at 5 weeks of age in all ewe lambs and declined thereafter to a nadir at 30 weeks of age in control, but not in naloxone-treated animals (P less than 0.05). LH pulse frequency was elevated at 10 weeks of age in control ewe lambs and in all animals at 30 weeks of age (P less than 0.05). FSH pulse frequency declined from 5 weeks of age in control ewe lambs (P less than 0.05), with very few pulses noted in 25- and 30-week-old animals. We conclude that (1) opioidergic suppression of LH, but not FSH, secretion developed at 20 weeks of age in the growing ewe lambs used in the present study, with no obvious change in suppression before the onset of first oestrus: (2) pulsatile FSH secretion occurred in the young ewe lamb but was lost as the lamb matured: (3) attainment of sexual maturity was preceded by an elevation in LH pulse frequency.  相似文献   

15.
Previously we introduced image correlation spectroscopy (ICS) as an imaging analog of fluorescence correlation spectroscopy (FCS). Implementation of ICS with image collection via a standard fluorescence confocal microscope and computer-based autocorrelation analysis was shown to facilitate measurements of absolute number densities and determination of changes in aggregation state for fluorescently labeled macromolecules. In the present work we illustrate how to use ICS to quantify the aggregation state of immunolabeled plasma membrane receptors in an intact cellular milieu, taking into account background fluorescence. We introduce methods that enable us to completely remove white noise contributions from autocorrelation measurements for individual images and illustrate how to perform background corrections for autofluorescence and nonspecific fluorescence on cell population means obtained via ICS. The utilization of photon counting confocal imaging with ICS analysis in combination with the background correction techniques outlined enabled us to achieve very low detection limits with standard immunolabeling methods on normal, nontransformed human fibroblasts (AG1523) expressing relatively low numbers of platelet-derived growth factor-beta (PDGF-beta) receptors. Specifically, we determined that the PDGF-beta receptors were preaggregated as tetramers on average with a mean surface density of 2.3 clusters micrometer(-2) after immunolabeling at 4 degreesC. These measurements, which show preclustering of PDGF-beta receptors on the surface of normal human fibroblasts, contradict a fundamental assumption of the ligand-induced dimerization model for signal transduction and provide support for an alternative model that posits signal transduction from within preexisting receptor aggregates.  相似文献   

16.
Two experiments were conducted in Ile-de-France ewes to study changes in pulsatile LH secretion in ewes ovariectomized during anoestrus or during the midluteal phase of the oestrous cycle. In Exp. 1, blood samples were taken every 20 min for 12 h the day before ovariectomy (Day 0). After ovariectomy, samples were taken every 10 min for 6 h (10 ewes per group), on Days 1, 3, 7 and 15. In Exp. 2 samples were taken every 10 min for 6 h (10 ewes per group) on Days 7, 15, 30, 60, 90, 120, 150 and 180 after ovariectomy. Further samples were taken (5 ewes per group) at 9 and 12 months after ovariectomy. There were significant interactions between season and day of sampling for the interval between LH pulses in both experiments. LH pulse frequency increased within 1 day of ovariectomy and the increase was more rapid during the breeding season. There were clear seasonal differences in pulse frequency in Exp. 2. Compared with ewes ovariectomized in anoestrus, pulse frequency was significantly higher for ewes ovariectomized in the breeding season, from Day 7 until Day 120. Once pulse frequency had increased in ewes about the time of the normal breeding season, pulse frequency remained high and subsequent seasonal changes were greatly reduced. Pulse amplitude increased immediately after ovariectomy to reach a maximum on Day 7 and there were no differences between season of ovariectomy in the initial changes in amplitude. In Exp. 2, changes in amplitude followed changes in pulse interval and there was a significant interaction between season and day of sampling. There were no significant effects of season on nadir LH concentrations which increased throughout the duration of the experiments. These results show that, in ovariectomized ewes, LH pulse frequency observed on a given day depends on time after ovariectomy, season at the time of sampling and on previous exposure of ewes to stimulatory effects of season. The direct effects of season on LH pulse frequency and seasonal changes in sensitivity to steroid feedback may contribute to control of the breeding season and their relative contributions to the beginning and end of the breeding season may differ.  相似文献   

17.
Chloroplast, an organelle facilitating photosynthesis, exhibits strong autofluorescence, which is an undesired background signal that restricts imaging experiments with exogenous fluorophore in plants. In this study, the autofluorescence was characterized in planta under confocal laser microscopy, and it was found that the time-gated imaging technique completely eliminates the autofluorescence. As a demonstration of the technique, a clearer signal of fluorescent protein-tagged phototropin, a blue-light photoreceptor localized at the chloroplast periphery, was visualized in planta.  相似文献   

18.
M Roederer  R F Murphy 《Cytometry》1986,7(6):558-565
Autofluorescence of cells can be a major portion of the fluorescence signal in many systems, especially when fluorescent conjugates are used to study receptor-ligand systems for which there are less than 70,000 receptors per cell. We have devised a method for the cell-by-cell correction of autofluorescence for flow cytometric data by using an additional parameter to measure and correct for autofluorescence in the fluorescence channel. The principle has been extended to allow simultaneous correction for autofluorescence and dual-fluorescence spillover compensation in samples labeled with two different fluorochromes; all corrections were done in software, making them applicable to any flow cytometer. The autofluorescence correction method was used to analyze the acidification of epidermal growth factor (EGF) by Swiss 3T3 cells. EGF is acidified to pH 6.2 starting two min after labeling, with a half-time for acidification of 45 s.  相似文献   

19.
20.
Rouyar A  Party V  Prešern J  Blejec A  Renou M 《PloS one》2011,6(10):e26443
In nature the aerial trace of pheromone used by male moths to find a female appears as a train of discontinuous pulses separated by gaps among a complex odorant background constituted of plant volatiles. We investigated the effect of such background odor on behavior and coding of temporal parameters of pheromone pulse trains in the pheromone olfactory receptor neurons of Spodoptera littoralis. Effects of linalool background were tested by measuring walking behavior towards a source of pheromone. While velocity and orientation index did drop when linalool was turned on, both parameters recovered back to pre-background values after 40 s with linalool still present. Photo-ionization detector was used to characterize pulse delivery by our stimulator. The photo-ionization detector signal reached 71% of maximum amplitude at 50 ms pulses and followed the stimulus period at repetition rates up to 10 pulses/s. However, at high pulse rates the concentration of the odorant did not return to base level during inter-pulse intervals. Linalool decreased the intensity and shortened the response of receptor neurons to pulses. High contrast (>10 dB) in firing rate between pulses and inter-pulse intervals was observed for 1 and 4 pulses/s, both with and without background. Significantly more neurons followed the 4 pulses/s pattern when delivered over linalool; at the same time the information content was preserved almost to the control values. Rapid recovery of behavior shows that change of perceived intensity is more important than absolute stimulus intensity. While decreasing the response intensity, background odor preserved the temporal parameters of the specific signal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号