首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ABSTRACT

Malignant liver tumors are the sixth most common and deadly cancer in the world and the third most common cause of cancer mortality. Hepatocellular carcinoma (primary liver cancer) is one of the most common malignancies worldwide with one of the highest mortality rates. Microwave ablation (MWA) is a new, promising, and multidisciplinary technology designed to destroy unhealthy tissue of various natures by radiating electromagnetic waves with microwave antennas. The finite element method (FEM) has been used in the present work to generate the simulated models of tapered cap floating sleeve antenna for validation of its design concepts, because FEM allows modeling of complex geometries that cannot be solved by analytical methods or finite difference models. The performances have been evaluated in terms of objective metrics, ablation zone, antenna matching, power absorption and SAR pattern.  相似文献   

2.
ABSTRACT

Microwave ablation is rapidly being rediscovered and developed for treating many cancers of liver, lung, kidney and bone, as well as arrhythmias and other medical conditions. The microwaves ablate tissue by heating it to cytotoxic temperatures. The microwave antenna design suffers the challenges of effective coupling and penetration into body tissues, uncontrolled power deposition due to applicator construction limitations affecting uniform heating of target region, and narrowband operation leading to mismatch for many patients and detrimental heating. To meet out the requirements of wideband operation and localized lesion reconfigurable linearly tapered slot interstitial wideband antenna has been proposed for working in the 1.38?GHz to 4.31?GHz frequency band. The performance of the antenna is evaluated by using FEM-based HFSS software. The slot height and taper height are reconfigured for parametric analysis achieving maximum impedance matching and spherical ablation zone without requiring any additional adjustable structures. The tapering of the slot in coaxial antenna generates current distribution at the edges of the slot for maximizing specific absorption rate.  相似文献   

3.
Microwave (MW) antenna is a key element in microwave ablation (MWA) treatments as the means that energy is delivered in a focused manner to the tumor and its surrounding area. The energy delivered results in a rise in temperature to a lethal level, resulting in cell death in the ablation zone. The delivery of energy and hence the success of MWA is closely dependent on the structure of the antennas. Therefore, three design criteria, such as expected ablation zone pattern, efficiency of energy delivery, and minimization of the diameter of the antennas have been the focus along the evolution of the MW antenna. To further improve the performance of MWA in the treatment of various tumors through inventing novel antennas, this article reviews the state-of-the-art and summarizes the development of MW antenna designs regarding the three design criteria.  相似文献   

4.
Implantable neural interfaces are designed to provide a high spatial and temporal precision control signal implementing high degree of freedom real-time prosthetic systems. The development of a Radio Frequency (RF) wireless neural interface has the potential to expand the number of applications as well as extend the robustness and longevity compared to wired neural interfaces. However, it is well known that RF signal is absorbed by the body and can result in tissue heating. In this work, numerical studies with analytical validations are performed to provide an assessment of power, heating and specific absorption rate (SAR) associated with the wireless RF transmitting within the human head. The receiving antenna on the neural interface is designed with different geometries and modeled at a range of implanted depths within the brain in order to estimate the maximum receiving power without violating SAR and tissue temperature elevation safety regulations. Based on the size of the designed antenna, sets of frequencies between 1 GHz to 4 GHz have been investigated. As expected the simulations demonstrate that longer receiving antennas (dipole) and lower working frequencies result in greater power availability prior to violating SAR regulations. For a 15 mm dipole antenna operating at 1.24 GHz on the surface of the brain, 730 uW of power could be harvested at the Federal Communications Commission (FCC) SAR violation limit. At approximately 5 cm inside the head, this same antenna would receive 190 uW of power prior to violating SAR regulations. Finally, the 3-D bio-heat simulation results show that for all evaluated antennas and frequency combinations we reach FCC SAR limits well before 1 °C. It is clear that powering neural interfaces via RF is possible, but ultra-low power circuit designs combined with advanced simulation will be required to develop a functional antenna that meets all system requirements.  相似文献   

5.
The aim of this project was to develop an animal exposure system for the biological effect studies of radio frequency fields from handheld wireless telephones, with energy deposition in animal brains comparable to those in humans. The finite‐difference time‐domain (FDTD) method was initially used to compute specific absorption rate (SAR) in an ellipsoidal rat model exposed with various size loop antennas at different distances from the model. A 3 × 1 cm rectangular loop produced acceptable SAR patterns. A numerical rat model based on CT images was developed by curve‐fitting Hounsfield Units of CT image pixels to tissue dielectric properties and densities. To design a loop for operating at high power levels, energy coupling and impedance matching were optimized using capacitively coupled feed lines embedded in a Teflon rod. Sprague Dawley rats were exposed with the 3 × 1 cm loop antennas, tuned to 837 or 1957 MHz for thermographically determined SAR distributions. Point SARs in brains of restrained rats were also determined thermometrically using fiberoptic probes. Calculated and measured SAR patterns and results from the various exposure configurations are in general agreement. The FDTD computed average brain SAR and ratio of head to whole body absorption were 23.8 W/kg/W and 62% at 837 MHz, and 22.6 W/kg/W and 89% at 1957 MHz. The average brain to whole body SAR ratio was 20 to 1 for both frequencies. At 837 MHz, the maximum measured SAR in the restrained rat brains was 51 W/kg/W in the cerebellum and 40 W/kg/W at the top of the cerebrum. An exposure system operating at 837 MHz is ready for in vivo biological effect studies of radio frequency fields from portable cellular telephones. Two‐tenths of a watt input power to the loop antenna will produce 10 W/kg maximum SAR, and an estimated 4.8 W/kg average brain SAR in a 300 g medium size rat. Bioelectromagnetics 20:75–92, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

6.
The use of microwave energy for ablation of the atrioventricular (AV) junction was examined in open-chest dogs. Using a specially designed microwave catheter and a 2450 MHz generator, microwave energy was delivered to the AV junction according to one of two protocols. In protocol 1, increasing amounts of energy were delivered until irreversible AV block occurred. In protocol 2, only two applications of energy were used, one at low energy and the other at an energy found to be high enough to cause irreversible AV block. Each dog received between one and six applications of microwave energy. The amount of energy delivered per application ranged from 25.6 to 311.4 J. No AV block was seen at 59.4 ± 28.3 J. Reversible AV block was seen with an energy of 120.6 ± 58 J. Irreversible AV block was seen at 188.1 ± 75.9 J. Irreversible AV block could be achieved in each animal. There was no difference in the energy required to cause irreversible AV block between the two protocols. The tissue temperature measured near the tip of the microwave catheter was correlated with both the amount of energy delivered and the extent of AV block caused. Histologic examination demonstrated coagulation necrosis of the conduction system. Microwave energy is a feasible alternative energy source for myocardial ablation. Since tissue damage is due exclusively to heating and the resulting rise in temperature can be measured, microwave energy may have advantages over currently existing energy sources in terms of both titrating delivered energy and monitoring the extent of tissue destruction. © 1995 Wiley-Liss, Inc.  相似文献   

7.
In this article, new interstitial antenna operating at a frequency of 2.45 GHz for the treatment of hepatocellular carcinoma (HCC) using microwave ablation has been investigated. This antenna is basically an asymmetrical miniaturized choke dipole antenna with a pointed needle at the tip. A commercial finite element method (FEM) package, COMSOL Multiphysics 3.4a, has been used to simulate the performance of needle tip choke antenna. The performance of the antenna has been evaluated numerically, taking into account the specific absorption rate, antenna impedance matching and geometry of the obtained thermal lesion, and the temperature distribution plot obtained shows that maximum temperature was attained in this simulation. The antenna is also capable of creating a spherical-shaped ablation zone. The size and shape of the ablation zone can be slightly adjusted by adjusting the choke position in order to maintain spherical ablation zones.  相似文献   

8.
In this work, the effect of antenna element loading on the localized specific absorption rate (SAR) has been analyzed for base station antennas. The analysis was conducted in order to determine whether localized SAR measurements of large multi-element base station antennas can be conducted using standardized procedures and commercially available equipment. More specifically, it was investigated if the antenna shifting measurement procedure, specified in the European base station exposure assessment standard EN 50383, will produce accurate localized SAR results for base station antennas larger than the specified measurement phantom. The obtained results show that SAR accuracy is affected by the presence of lossy material within distances of one wavelength from the tested antennas as a consequence of coupling and redistribution of transmitted power among the antenna elements. It was also found that the existing standardized phantom is not optimal for SAR measurements of large base station antennas. A new methodology is instead proposed based on a larger, box-shaped, whole-body phantom.  相似文献   

9.
Human exposure to electromagnetic fields produced by two wearable antennas operating in the 2.4 GHz frequency band was assessed by computational tools. Both antennas were designed to be attached to the skin, but they were intended for different applications. The first antenna was designed for off-body applications, i.e. to communicate with a device placed outside the body, while the second antenna model was optimized to communicate with a device located inside the body. The power absorption in human tissues was determined at several locations of adult male and female body models. The maximum specific absorption rate (SAR) value obtained with the off-body antenna was found on the torso of the woman model and was equal to 0.037 W/kg at 2.45 GHz. SAR levels increased significantly for the antenna transmitting inside the body. In this case, SAR values ranged between 0.23 and 0.45 W/kg at the same body location. The power absorbed in different body tissues and total power absorbed in the body were also calculated; the maximum total power absorbed was equal to 5.2 mW for an antenna input power equal to 10 mW. Bioelectromagnetics. 2020;41:73–79 © 2019 Wiley Periodicals, Inc.  相似文献   

10.
In this article, the exposure to radio frequency electromagnetic fields was studied in close proximity (distances of 10, 100, 300, and 600 mm) to six base station antennas. The specific absorption rate (SAR) in 800 mm × 500 mm × 200 mm box phantom as well as unperturbed electric field (E) in air was measured. The results were used to determine whether the measurement of local maximum of unperturbed electric field can be used as a compliance check for local exposure. Also, the conservativeness of this assessment method compared to the ICNIRP basic restriction was studied. Moreover, the assessment of whole‐body exposure was discussed and the distance ranges presented in which the ICNIRP limit for local exposure could be exceeded before the limit for whole‐body SAR. These results show that the electric field measurement alone can be used for easy compliance check for the local exposure at all distances and for all antenna types studied. However, in some cases when the local peak value of E was compared directly to the ICNIRP reference level for unperturbed E, the exposure was overestimated only very slightly (by factor 1.1) compared to the basic restriction for localized SAR in a human, and hence these results can not be generalized to all antenna types. Moreover, it was shown that the limit for localized exposure could be exceeded before the limit for the whole‐body average SAR, if the distance to the antenna was less than 240 mm. Bioelectromagnetics 30:307–312, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

11.
12.
This study investigates occupational exposure to electromagnetic fields in front of a multi‐band base station antenna for mobile communications at 900, 1800, and 2100 MHz. Finite‐difference time‐domain method was used to first validate the antenna model against measurement results published in the literature and then investigate the specific absorption rate (SAR) in two heterogeneous, anatomically correct human models (Virtual Family male and female) at distances from 10 to 1000 mm. Special attention was given to simultaneous exposure to fields of three different frequencies, their interaction and the additivity of SAR resulting from each frequency. The results show that the highest frequency—2100 MHz—results in the highest spatial‐peak SAR averaged over 10 g of tissue, while the whole‐body SAR is similar at all three frequencies. At distances >200 mm from the antenna, the whole‐body SAR is a more limiting factor for compliance to exposure guidelines, while at shorter distances the spatial‐peak SAR may be more limiting. For the evaluation of combined exposure, a simple summation of spatial‐peak SAR maxima at each frequency gives a good estimation for combined exposure, which was also found to depend on the distribution of transmitting power between the different frequency bands. Bioelectromagnetics 32:234–242, 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

13.
The interaction of body‐worn antennas with the human body causes a significant decrease in antenna efficiency and a shift in resonant frequency. A resonant slot in a small conductive box placed on the body has been shown to reduce these effects. The specific absorption rate is less than international health standards for most wearable antennas due to small transmitter power. This paper reports the linear relationship between power absorbed by biological tissues at different locations on the body and radiation efficiency based on numerical modeling (r = 0.99). While the ?10 dB bandwidth of the antenna remained constant and equal to 12.5%, the maximum frequency shift occurred when the antenna was close to the elbow (6.61%) and on the thigh (5.86%). The smallest change was found on the torso (4.21%). Participants with body‐mass index (BMI) between 17 and 29 kg/m2 took part in experimental measurements, where the maximum frequency shift was 2.51%. Measurements showed better agreement with simulations on the upper arm. These experimental results demonstrate that the BMI for each individual had little effect on the performance of the antenna. Bioelectromagnetics. 39:25–34, 2018. © 2017 Wiley Periodicals, Inc.  相似文献   

14.
Cancers of the neck, breast, and lower extremities are common malignancies diagnosed in India with a higher incidence of advanced-stage disease. Phased array (PA) applicators reported for hyperthermia treatment (HT) of the breast have small focal region and high cross-coupling, and those reported for lower extremities provide regional heating and limited steering. In this study, we present the numerical design of site-specific PA applicators for HT of large solid tumors in the neck, breast, and lower extremities using a miniaturized 434 MHz cavity-backed water-loaded patch antenna. The fabricated antenna has 38 × 36 mm2 aperture, more than 90% power coupling, 25 MHz bandwidth, and good agreement between simulated and measured specific absorption rate (SAR) in phantom. The site-specific applicators demonstrated less power reflection (<−17.9 dB) and cross-coupling (<−26.8 dB) for 5 mm inter-ring spacing. SAR indicators for 64 cc tumor at varying locations in simplified layered three-dimensional (3D) tissue models of the neck, breast, and leg showed average power absorption ratio (aPAratio) ≥ 3.16, target to hotspot quotient (THQ) ≥ 0.57, 25% iso-SAR coverage (TC25) ≥ 81%, and 50% iso-SAR coverage (TC50) ≥51.8%. Simulation results of site-specific applicators for 3D inhomogeneous patient models showed aPAratio ≥ 5.98, THQ ≥ 0.9, TC50 ≥ 86%, and 100% TC25 for all sites. It is concluded that the 434 MHz miniaturized cavity-backed patch antenna can be used to develop high-density PA applicators with 12–24 antennas for HT of large solid tumors (≥4 cm) in the neck, breast, and lower extremities with 3D steering ability and less cross-coupling (≤−26.8 dB). © 2020 Bioelectromagnetics Society  相似文献   

15.
We have developed a carrousel irradiator for mice which delivers a head‐first and near‐field radiofrequency exposure that more closely simulates cellular telephone and radio use than conventional whole body exposure systems. Mouse cadavers were placed on the carrousel irradiator and exposed with their noses 5 mm from the feedpoint of a 1.6 GHz antenna. Local measured specific absorption rates (SAR) in brain regions corresponding to the frontal cortex, medial caudate putamen, and midhippocampal areas were 2.9, 2.4, and 2.2 W/kg per watt of irradiated power, respectively. In addition, average SAR was estimated to be 3.4 W/kg per watt along the sagittal plane of the brain, 2.0 W/kg per watt along the sagittal plane of the body, and between 6.8 and 8.1 W/kg per watt at peak locations along the sagittal plane at the body surface. This detailed SAR information in mice is critical to the interpretation of biological studies of IRIDIUM exposure, and similar analysis should be included for all studies of in vivo exposure of small animals to microwaves. Bioelectromagnetics 20:42–47, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

16.
This article deals with the safety assessment of several ultra-wideband (UWB) antenna designs for use in prototype microwave breast imaging systems. First, the performances of the antennas are validated by comparison of measured and simulated data collected for a simple test case. An efficient approach to estimating the specific energy absorption (SA) is introduced and validated. Next, SA produced by the UWB antennas inside more realistic breast models is computed. In particular, the power levels and pulse repetition periods adopted for the SA evaluation follow the measurement protocol employed by a tissue sensing adaptive radar (TSAR) prototype system. Results indicate that the SA for the antennas examined is below limits prescribed in standards for exposure of the general population; however, the difficulties inherent in applying such standards to UWB exposures are discussed. The results also suggest that effective tools for the rapid evaluation of new sensors have been developed.  相似文献   

17.
Lin JC 《Bioelectromagnetics》2004,25(3):146-159
This d'Arsonval Medal acceptance presentation highlights several research themes selected from Dr. Lin's published works, focusing on the microwave portion of the nonionizing electromagnetic spectrum. The topics discussed include investigation of microwave effects on the spontaneous action potentials and membrane resistance of isolated snail neurons, effects on the permeability of blood brain barriers in rats, the phenomenon and interaction mechanism for the microwave auditory effect (the hearing of microwave pulses by animals and humans), the development of miniature catheter antennas for microwave interstitial hyperthermia treatment of cancer, the application of transcatheter microwave ablation for treatment of cardiac arrhythmias, and the use of noninvasive wireless technology for sensing of human vital signs and blood pressure pulse waves. The paper concludes with some observations on research and other endeavors in the interdisciplinary field of bioelectromagnetics.  相似文献   

18.
The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.  相似文献   

19.
International bodies such as International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Institute for Electrical and Electronic Engineering (IEEE) make provision for human exposure assessment based on SAR calculations (or measurements) and basic restrictions. In the case of base station exposure this is mostly applicable to occupational exposure scenarios in the very near field of these antennas where the conservative reference level criteria could be unnecessarily restrictive. This study presents a variety of critical aspects that need to be considered when calculating SAR in a human body close to a mobile phone base station antenna. A hybrid FEM/MoM technique is proposed as a suitable numerical method to obtain accurate results. The verification of the FEM/MoM implementation has been presented in a previous publication; the focus of this study is an investigation into the detail that must be included in a numerical model of the antenna, to accurately represent the real-world scenario. This is accomplished by comparing numerical results to measurements for a generic GSM base station antenna and appropriate, representative canonical and human phantoms. The results show that it is critical to take the disturbance effect of the human phantom (a large conductive body) on the base station antenna into account when the antenna-phantom spacing is less than 300 mm. For these small spacings, the antenna structure must be modeled in detail. The conclusion is that it is feasible to calculate, using the proposed techniques and methodology, accurate occupational compliance zones around base station antennas based on a SAR profile and basic restriction guidelines.  相似文献   

20.
A dual-band microstrip antenna operating at GSM 900 and GSM 1800 MHz is designed initially. Then a single split ring resonator (SRR) structure is used as a superstrate for this dual-band antenna. A circular current is induced in the SRR due to the perpendicular plane wave excitation, which in turn leads to an electric excitation coupled to the magnetic resonance. It also exhibits higher order excitations at 0.9 and 1.8 GHz which ultimately resulted in specific absorption rate (SAR) reduction of human head at both the designed frequencies of the antenna. The antenna and the SRR superstrate are printed on a 1.6 mm thick FR-4 substrate of dimension 59.6 × 49.6 mm2. Analysis of the SRR using the classic waveguide theory approach is discussed. Radiation pattern of the antenna in the presence of SRR superstrate and human head is also discussed. Prototype of the antenna along with the SRR superstrate is fabricated and measured for return loss and radiation pattern. Measurement results fairly agree with the simulated results. A human head phantom is utilized in the calculation of SAR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏