首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVES: To evaluate the accuracy of intrapartum foetal pulse oximetry (SO(2POX)) using reusable sensors and the effect of a sensor performance test on data quality. Furthermore, to assess the sensor-related costs by using reusable sensors and sensor performance test. METHODS: 36 reusable sensors were used for SO(2POX) during labour of 289 term foetuses. A sensor performance test device assessing the emitter and receiver capability and the firmness of attachment of the sensors had been developed and used in the last 134 measurements before each resterilisation. Oxygen saturation (SaO(2)) at birth was measured spectrophotometrically after cord blood sampling. The accuracy of SO(2POX) was evaluated by analysing its relationship to SaO(2). The valid SO(2POX) data, as confirmed by subsequent sensor test in the second group, was considered comparable with those with single sensor use. Sensor-related average cost (sensors, test device and sterilisation) of such measurements was compared with that of single sensor use. RESULTS: Eight sensors failed performance test despite valid pulse oximetry signal output during their last measurements. There were significant overall linear correlations between SO(2POX) and SaO(2) (r=0.45, P<0.0001). Separate analyses of regression in the group without sensor performance testing showed an r(2) of 0.41, whereas in the group with subsequent sensor performance testing, the r(2) was 0.52 (P<0.05). By reusing the sensors, the sensor-related cost per valid measurement was $18.9 and 71% lower compared to single use of sensors ($65). CONCLUSIONS: Pulse oximetry may reflect fetal oxygen saturation. Data quality may be compromised by insufficient sensor performance, even though the reflection signal quality is acceptable. If sensor performance is tested before each measurement, reusable sensors may reduce the costs of fetal pulse oximetry.  相似文献   

2.
Children''s hospitals in developing countries carry an enormous patient load. Available facilities must be organized to provide essential care for all. At the Red Cross Children''s Hospital in Cape Town this has been achieved by the development of an emergency ward attached to the outpatient department. It is suggested that this concept should be applied in large hospitals of other developing countries.  相似文献   

3.
This paper introduces passive wireless telemetry based operation for high frequency acoustic sensors. The focus is on the development, fabrication, and evaluation of wireless, battery-less SAW-IDT MEMS microphones for biomedical applications. Due to the absence of batteries, the developed sensors are small and as a result of the batch manufacturing strategy are inexpensive which enables their utilization as disposable sensors. A pulse modulated surface acoustic wave interdigital transducer (SAW-IDT) based sensing strategy has been formulated. The sensing strategy relies on detecting the ac component of the acoustic pressure signal only and does not require calibration. The proposed sensing strategy has been successfully implemented on an in-house fabricated SAW-IDT sensor and a variable capacitor which mimics the impedance change of a capacitive microphone. Wireless telemetry distances of up to 5 centimeters have been achieved. A silicon MEMS microphone which will be used with the SAW-IDT device is being microfabricated and tested. The complete passive wireless sensor package will include the MEMS microphone wire-bonded on the SAW substrate and interrogated through an on-board antenna. This work on acoustic sensors breaks new ground by introducing high frequency (i.e., audio frequencies) sensor measurement utilizing SAW-IDT sensors. The developed sensors can be used for wireless monitoring of body sounds in a number of different applications, including monitoring breathing sounds in apnea patients, monitoring chest sounds after cardiac surgery, and for feedback sensing in compression (HFCC) vests used for respiratory ventilation. Another promising application is monitoring chest sounds in neonatal care units where the miniature sensors will minimize discomfort for the newborns.  相似文献   

4.
M OReilly 《CMAJ》1996,154(9):1401-1402
Two of London''s three major teaching hospitals joined forces recently to form Canada''s second-largest teaching hospital. The merger is considered a harbinger as teaching hospitals strive to maintain current teaching, research and clinical activities in the face of decreasing government spending.  相似文献   

5.
目的 探讨医院实施岗位设置管理工作的做法,确保医院岗位设置管理工作顺利实施。方法 按照上级人事部门核准的事业单位岗位设置审核方案,结合自身实际,制定切实可行的医院岗位设置管理实施方案。结果 医院岗位设置管理工作顺利实施,效果显著。结论 要确保医院岗位设置管理工作顺利实施,领导重视是关键,全员参与是保障,公平公开是前提,按需设置是基础,激励约束是目的。  相似文献   

6.

Background

Sleep disordered breathing (SDB) can lead to daytime sleepiness, growth failure and developmental delay in children. Polysomnography (PSG), the gold standard to diagnose SDB, is a highly resource-intensive test, confined to the sleep laboratory.

Aim

To combine the blood oxygen saturation (SpO2) characterization and cardiac modulation, quantified by pulse rate variability (PRV), to identify children with SDB using the Phone Oximeter, a device integrating a pulse oximeter with a smartphone.

Methods

Following ethics approval and informed consent, 160 children referred to British Columbia Children''s Hospital for overnight PSG were recruited. A second pulse oximeter sensor applied to the finger adjacent to the one used for standard PSG was attached to the Phone Oximeter to record overnight pulse oximetry (SpO2 and photoplethysmogram (PPG)) alongside the PSG.

Results

We studied 146 children through the analysis of the SpO2 pattern, and PRV as an estimate of heart rate variability calculated from the PPG. SpO2 variability and SpO2 spectral power at low frequency, was significantly higher in children with SDB due to the modulation provoked by airway obstruction during sleep (p-value ). PRV analysis reflected a significant augmentation of sympathetic activity provoked by intermittent hypoxia in SDB children. A linear classifier was trained with the most discriminating features to identify children with SDB. The classifier was validated with internal and external cross-validation, providing a high negative predictive value (92.6%) and a good balance between sensitivity (88.4%) and specificity (83.6%). Combining SpO2 and PRV analysis improved the classification performance, providing an area under the receiver operating characteristic curve of 88%, beyond the 82% achieved using SpO2 analysis alone.

Conclusions

These results demonstrate that the implementation of this algorithm in the Phone Oximeter will provide an improved portable, at-home screening tool, with the capability of monitoring patients over multiple nights.  相似文献   

7.
During exercise, pulse oximetry is problematic due to motion artifact and altered digital perfusion. New pulse oximeter technology addresses these issues and may offer improved performance. We simultaneously compared Nellcor N-395 (Oxismart XLTM) pulse oximeters with an RS-10 forehead sensor (RS-10), a D-25 digit sensor (D-25), and the Ivy 2000 (Masimo SETTM)/LNOP-Adt digit sensor (Ivy) to arterial blood oxygen saturation (Sa(O(2))) by cooximetry. Nine normal subjects, six athletes, and four patients with chronic disease exercised to maximum oxygen consumption (VO(2 max)) under various conditions [normoxia, hypoxia inspired oxygen fraction (FI(O(2))) = 0.125; hyperoxia, FI(O(2)) = 1.0]. Regression analysis for normoxia and hypoxic data was performed (n = 161 observations, Sa(O(2)) = 73-99.9%), and bias (B) and precision (P) were calculated. RS10 offered greater validity than the other two devices tested (y = 1.009x - 0.52, R(2) = 0.90, B+/-P = 0.3 +/- 2.5). Finger sensors had low precision and a significant negative bias (D-25: y = 1.004x - 2.327, R(2) = 0.52, B+/-P = -2.0 +/- 7.3; Ivy: y = 1.237x - 24.2, R(2) = 0.78, B+/-P = -2.0 +/- 5.2). Eliminating measurements in which heart rate differed by >10 beats/min from the electrocardiogram value improved precision minimally and did not affect bias substantially (B+/-P = 0.5 +/- 2.0, -1.8 +/- 8.4, and -1.25+/-4.33 for RS-10, D-25, and Ivy, respectively). Signal detection algorithms and pulse oximeter were identical between RS-10 and D-25; thus the improved performance of the forehead sensor is likely because of sensor location. RS-10 should be considered for exercise testing in which pulse oximetry is desirable.  相似文献   

8.
《IRBM》2023,44(3):100745
ObjectivesIn this paper, we present a plugin for the optimal placement of sensors in a smart home. Our approach includes the Building Information Modeling (BIM) which is a plan that describes the building layout.Material and methodsThis plugin uses the CSTB EveBim viewer for loading IFC file representing the digital building's model. We use then, a mathematical model based on a mixed integer linear program, to determine the optimal sensor placement according to building and sensors characteristics.ResultsThe results show the efficiency of the proposed algorithm and the developed plugin. We obtain an optimal solution after few seconds, and we show the sensor placement on the building digital model.ConclusionWe show the relevance of the proposed plugin to equip room of retirement home or ambient assisted living in order to identify occupant activity for home support application.  相似文献   

9.
WHO in crisis.     
Media attention has been focused on the leadership of the World Health Organisation, rather than on the real factors that limit WHO''s effectiveness. These factors relate to the organisation''s structure and also to its current priorities, methods, and management. This article examines the objectives and strategy of WHO in view of financial constraints and donor countries'' demands; WHO''s stated goal of integrated primary health care; staff morale; and the growing dislocation between the regions and headquarters.  相似文献   

10.
Liver transplants have their highest technical failure rate in the first two weeks following surgery. Currently, there are limited devices for continuous, real-time monitoring of the graft. In this work, a three wavelengths system is presented that combines near-infrared spectroscopy and photoplethysmography with a processing method that can uniquely measure and separate the venous and arterial oxygen contributions. This strategy allows for the quantification of tissue oxygen consumption used to study hepatic metabolic activity and to relate it to tissue stress. The sensor is battery operated and communicates wirelessly with a data acquisition computer which provides the possibility of implantation provided sufficient miniaturization. In two in vivo porcine studies, the sensor tracked perfusion changes in hepatic tissue during vascular occlusions with a root mean square error (RMSE) of 0.135 mL/min/g of tissue. We show the possibility of using the pulsatile wave to measure the arterial oxygen saturation similar to pulse oximetry. The signal is also used to extract the venous oxygen saturation from the direct current (DC) levels. Arterial and venous oxygen saturation changes were measured with an RMSE of 2.19% and 1.39% respectively when no vascular occlusions were induced. This error increased to 2.82% and 3.83% when vascular occlusions were induced during hypoxia. These errors are similar to the resolution of a commercial oximetry catheter used as a reference. This work is the first realization of a wireless optical sensor for continuous monitoring of hepatic hemodynamics.  相似文献   

11.

Background

There have been many studies that utilize the bio-impedance measurement method to analyze the movements of the upper and lower limbs. A fixed electrical current flows into the limbs through four standard disposable electrodes in this method. The current flows in the muscles and blood vessels, which have relatively low resistivity levels in the human body. This method is used to measure bio-impedance changes following volume changes of muscles and blood vessels around a knee joint. The result of the bio-impedance changes is used to evaluate the movements. However, the method using the standard disposable electrodes has a restriction related to its low bio-impedance changes: the standard disposable electrodes are only able to measure bio-impedance from a limited part of a muscle. Moreover, it is impossible to use continuously, as the electrodes are designed to be disposable. This paper describes a conductive fabric sensor (CFS) using a bio-impedance measurement method and determines the optimum configuration of the sensor for estimating knee joint movements.

Methods

The upper side of subjects' lower limbs was divided into two areas and the lower side of subjects' lower limbs was divided into three areas. The spots were matched and 6 pairs were selected. Subjects were composed of 15 males (age: 30.7 ± 5.3, weight: 69.8 ± 4.2 kg, and height: 173.5 ± 2.8 cm) with no known problems with their knee joints. Bio-impedance changes according to knee joint flexion/extension assessments were calculated and compared with bio-impedance changes by an ankle joint flexion/extension test (SNR I) and a hip joint flexion/extension test (SNR II).

Results

The bio-impedance changes of the knee joint flexion/extension assessment were 35.4 ± 20.0 Ω on the (1, 5) pair. SNR I was 3.8 ± 8.4 and SNR II was 6.6 ± 7.9 on the (1, 5) pair.

Conclusions

The optimum conductive fabric sensor configuration for evaluating knee joint movements were represented by the (1, 5) pair.  相似文献   

12.
BackgroundTrichophyton tonsurans is a dermatophyte fungus that can cause ringworm outbreaks. In our health area in September 2013, two cases of T. tonsurans ringworm were diagnosed in children who lived in a Children's Centre.AimsTo determine the origin and extent of the outbreak.MethodsMycological cultures of scalp and skin samples from the contacts of the diagnosed cases were performed, as well as environmental samples from the Children's Centre. The patients started with a treatment for their ringworm, and an environmental disinfection of the centre was performed.ResultsTwelve cases of ringworm were detected, along with three asymptomatic scalp carriers of T. tonsurans among 20 children in the Centre. The index case was a resident in whose family, that had just returned from their country of origin, Nigeria, three cases of ringworm were diagnosed. From November 2013 to February 2014 another five cases of ringworm were diagnosed among schoolmates of three cases from the Children's Centre.ConclusionsThe antifungal treatment of the children resulted in the mycological and clinical resolution, and from February to November 2014 no other cases of ringworm by T. tonsurans in the same health area were diagnosed.  相似文献   

13.
领导力是现代医院实现创新转型的关键环节,其理论随着实践不断发展。文章分析了领导力的内涵和现代医院领导力的创新本质,并从组织文化、发展战略、信息化领导力和职业化管理四个方面探讨了领导力建设内容,并介绍了医院领导力建设成效以及下一步发展方向。  相似文献   

14.

Background

Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country.

Methods and Findings

In a pilot study performed at the University Malaya Medical Centre (UMMC), Malaysia, all apparently healthy term newborns, delivered at UMMC were screened pre-discharge using pulse oximetry. Echocardiography was performed for newborns that had positive screening results on two separate occasions, 1-h apart. Newborns with normal echocardiograms were evaluated and treated for other non-cardiac diseases. Fifteen of 5247 term newborns had positive screening results. The median age at screening was 20 h. Thirteen newborns (0.24%) had significant non-cardiac diseases: sepsis (n = 2) and respiratory diseases (n = 11) that required hospitalization and treatment. The remaining two newborns with normal antenatal ultrasonograms had positive screening test and confirmed to have CCHD. Another 18 newborns with negative screening test were later admitted for treatment of sepsis (n = 16) and penumonia (n = 2). All newborns were treated and alive at the end of the study. The sensitivity and specificity of pulse oximetry screening for non-cardiac diseases were 42% and 99.9% respectively, and 100% and 99.7% for CCHD, respectively.

Conclusions

Routine pulse oximetry screening test was effective in identifying newborns with CCHD and other hypoxemia illnesses, which may led to potential life-threatening condition. This study showed that the expanded use of pulse oximetry has immediate implications for low- and middle-income countries contemplating strategies to reduce neonatal mortality and morbidity.

Abbreviations

ASD, atrial septal defect; CCHD, critical congenital heart disease; CRP, C-reactive protein; CXR, chest radiographs; NDI, neurodevelopment impairment; PPHN, persistent pulmonary hypertension of the newborn; PDA, patent ductus arteriosus; PFO, patent foramen ovale; TGA, transposition of great artery; TTN, transient tachypnoea of the newborn; VSD, ventricular septal defect.  相似文献   

15.
The use of disposable bags for cell culture media storage has grown significantly in the past decade. Some of the key advantages of using disposable bags relative to non‐disposable containers include increased product throughput, decreased cleaning validation costs, reduced risk of cross contamination and lower facility costs. As the scope of use of disposable bags for cell culture applications increases, problematic bags and scenarios should be identified and addressed to continue improving disposables technologies and meet the biotech industry's needs. In this article, we examine a cell culture application wherein media stored in disposable bags is warmed at 37°C before use for cell culture operations. A problematic bag film was identified through a prospective and retrospective cell culture investigation. The investigation provided information on the scope and variation of the issue with respect to different Chinese hamster ovary (CHO) cell lines, cell culture media, and application‐specific parameters. It also led to the development of application‐specific test methods and enabled a strategy for disposable bag film testing. The strategy was implemented for qualifying an alternative bag film for use in our processes. In this test strategy, multiple lots of 13 bag film types, encompassing eight vendors were evaluated using a three round, cell culture‐based test strategy. The test strategy resulted in the determination of four viable bag film options based on the technical data. The results of this evaluation were used to conclude that a volatile or air‐quenched compound, likely generated by gamma irradiation of the problematic bag film, negatively impacted cell culture performance. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:1535–1549, 2013  相似文献   

16.
目的 分析综合医院对于大数据应用的内在需求,为医院的大数据研发与应用提供导向和依据。方法 采用德尔菲法自制医院大数据应用需求调查问卷,随机抽取中国研究型医院学会医疗分会64家会员单位进行调查,获得有效问卷104份,有效回收率为94.55%。结果 精准医疗(4.31±0.42)分,精益管理(4.23±0.56)分,科学研究(4.19±0.52)分,健康管理(4.16±0.52)分,数字医疗(4.06±0.60)分,教育培训(3.69±0.69)分。不同性别、年龄、职称、岗位组间的需求差异有统计学意义(P<0.05)。多元线性回归分析结果显示,医学人工智能(b=0.324,P=0.000)和互联网+医疗(b=0.161,P=0.047)的需求程度会对医院大数据应用前景态度产生显著的正向影响关系。结论 综合性医院对大数据具有较强的、多样化的应用需求,应以实际需求为导向,重点推进精准医疗、医学人工智能和互联网+医疗等相关应用的研发。  相似文献   

17.
New reactor concepts as multi-parallel screening systems or disposable bioreactor systems for decentralized and reproducible production increase the need for new and easy applicable sensor technologies to access data for process control. These sophisticated reactor systems require sensors to work with the lowest sampling volumes or, even better, to measure directly in situ, but in situ sensors are directly incorporated into a reactor or fermenter within the sterility barrier and have therefore to stand the sterilization procedures. Consequently, these in situ sensor technologies should enable the measurement of multi-analytes simultaneously online and in real-time at a low price for the robust sensing element. Current research therefore focuses on the implementation of noninvasive spectroscopic and optical technologies, and tries to employ them through fiber optics attached to disposable sensing connectors. Spectroscopic methods reach from ultraviolet to infrared and further comprising fluorescence and Raman spectroscopy. Also, optic techniques like microscopy are adapted for the direct use in bioreactor systems (Ulber et al. in Anal Bioanal Chem 376:342–348, 2003) as well as various electrochemical methods (Joo and Brown in Chem Rev 108:638–651, 2008). This review shows the variety of modern in situ sensing principles in bioprocess monitoring with emphasis on spectroscopic and optical techniques and the progress in the adaption to latest reactor concepts.  相似文献   

18.
The measurement of tissue oxygen saturation with a pulse oximeter is of proved value in the hospital setting. The development of a portable oximeter has allowed this investigation to be performed during the prehospital phase of a patient''s care. Pulse oximetry was performed at the roadside in 25 patients with abnormal trauma scores and found to be of benefit in detecting and monitoring hypoxia in patients with airway obstruction, depressed respiration due to head injury, and, in particular, with closed chest injuries. There were no practical difficulties associated with the use of the instrument either at the roadside or in a moving ambulance. The portable pulse oximeter is a valuable aid in the prehospital monitoring of patients with trauma.  相似文献   

19.
目的:探讨脉搏指数连续心输出量(PICCO)技术在重型颅脑损伤患者液体管理中的临床应用价值。方法:回顾性分析重型颅脑损伤患者46例(男性27例,女性19例),以应用PICCO技术监测血流动力学指标指导液体管理的患者为治疗组(n=26),未应用PICCO技术指导液体管理的患者为对照组(n=20)。比较两组患者的日平均液体量、格拉斯哥昏迷评分(GCS)、急性生理与慢性健康评分(APACHE II)、肺水肿发生率、住院时间、住院总费用以及治疗6个月后的格拉斯哥预后评分(GOS)、生存率、颅脑损伤恢复良好率。结果:治疗期间,治疗组的GCS评分以及APACHEII评分均优于对照组,而治疗组的住院总费用高于对照组,但差异并无统计学意义(P0.05)。治疗组的日平均液体量、肺水肿发生率及住院时间均明显少于对照组,差异有统计学意义(P0.05)。治疗6个月后,治疗组患者的GOS评分、生存率和颅脑损伤恢复良好率均高于对照组,但差异亦无统计学意义(P0.05)。结论:应用PICCO技术监测血流动力学指标指导重型颅脑损伤患者的容量管理可在一定程度上缩短危重患者的住院时间并降低肺水肿的发生率,但并不能明显改善患者的预后。  相似文献   

20.
摘要 目的:分析与探讨心脏超声在卵圆孔血流受限胎儿中的筛查价值。方法:2019年1月-2020年9月在本院进行产前心脏超声筛查的孕妇58例,都给予常规超声与组织多普勒成像,记录影像学特征并判断诊断价值。结果:58例胎儿判断为卵圆孔处血流受限18例,占比31.0 %。受限组的卵圆孔大小、卵圆瓣长度、继发隔长度都少于未受限组(P<0.05)。受限组的D-FOC值低于未受限组(P<0.05),Vm-PV、Vm-FOC值高于未受限组(P<0.05)。受限组的左心室E、A、E''、A''值都低于未受限组(P<0.05)。结论:心脏超声作为检出胎儿心脏畸形的有效手段,可通过观察胎儿卵圆孔血流频谱与形态来鉴别诊断卵圆孔血流受限,是孕期诊断卵圆孔血流受限的最有效方法之一。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号