首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AIMS: A monoclonal antibody (Mab 2F3)-based sandwich enzyme linked immunosorbent assay (sELISA) format for the detection of Escherichia coli O26 that improves the sensitivity of the assay by combining enrichment with the capture stage has been developed. Culture of the enriched contents of wells before completion of the sELISA was compared with immunomagnetic bead separation (IMS) as a means of specific isolation of the target organism. METHODS AND RESULTS: Bovine faecal samples, c. 10% in buffered peptone water (BPW), were pre-enriched for 6 h before testing by capture/enrichment sELISA and by IMS. The sELISA consisted of a 1-2 h capture stage followed by addition of BPW to the wells and an overnight enrichment stage before completion of the assay. The capture/enrichment stage of the assay was repeated a second time on the enriched contents removed from the wells before completion of the first sELISA. From 204 cattle faeces samples, 30x O26 strains [20x attachment effacement Escherichia coli (AEEC) and 10x non-AEEC] were isolated from the enriched wells of the sELISA, in comparison with 11 (9x AEEC and 2x non-AEEC) that were isolated by IMS. Examination of the use of enterohaemolysin activity and rhamnose utilization on 1% rhamnose McConkey's (RMAC) agar with or without cefixime and potassium tellurite demonstrated that the selection based on enterohaemolysin production and growth on RMAC with cefixime and potassium tellurite would largely differentiate the AEEC strains from the non-AEEC strains. CONCLUSIONS: The capture/enrichment sELISA protocol used compared favourably with the IMS for the isolation of E. coli O26 from faeces samples. The ELISA optical density readings obtained in the procedure were used as a screening indicator for selection of samples for further culture examination, and the selective culture methods examined to assist strain isolation did have potential. SIGNIFICANCE AND IMPACT OF THE STUDY: The capture/enrichment format of an Mab-based sELISA protocol has the potential to provide a suitable screening assay for the specific detection of pathogenic strains from mixed culture samples like faeces.  相似文献   

2.
AIMS: Production of a monoclonal antibody (MAb) to Escherichia coli O157 to develop a rapid test using a sandwich ELISA (sELISA) format. METHODS AND RESULTS: A MAb (7A6) was developed to the long-chain lipopolysaccharide of E. coli O157. A sELISA developed with the MAb reacted with 28 bovine and seven human enterohaemorrhagic E. coli (EHEC) O157 strains and also with two enterotoxigenic E. coli O157 strains. Cross-reaction to a rabbit diarrhoeal E.coli O15, Citrobacter freundii, Salmonella urbana and Vibrio cholerae O1 Inaba was detected. CONCLUSION: A MAb-based sELISA to detect E. coli O157 was produced. Its application to field samples is required to fully determine its prospective use for the detection of EHEC O157, to evaluate the non-specific interference of the cross-reacting strains. SIGNIFICANCE AND IMPACT OF THE STUDY: The assay produced is not wholly specific to EHEC O157, but has the potential to be used as a rapid method for screening large numbers of samples for E. coli O157.  相似文献   

3.
AIMS: To compare the sensitivity of two pre-enrichment broth media prior to immunomagnetic separation for the isolation of Escherichia coli O157 from cattle faeces. METHODS AND RESULTS: One-gram portions of 721 cattle faeces collected from 43 farms were pre-enriched in buffered peptone water containing vancomycin, cefixime and cefsulodin (BPW-VCC) and buffered peptone water without additives (BPW-WOA), respectively. A total of 137 samples were positive for E. coli O157: 127 pre-enriched with BPW-WOA and 89 pre-enriched in BPW-VCC. Representative isolates were tested for phage type, verotoxin and eae (E. coli attaching and effacing) gene sequences, resulting in the recognition of eight different types. All the E. coli O157 types recognized were isolated by both methods except for three different strains, each of which were isolated only on a single occasion: two by BPW-WOA and another by BPW-VCC. CONCLUSIONS: The results clearly demonstrate, under the conditions of this study, that BPW without antibiotics was the superior pre-enrichment medium for the isolation of E. coli O157 from cattle faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: The use of BPW-WOA in preference to BPW-VCC for the isolation of E. coli O157 from cattle faeces in future research and outbreak studies should lead to a higher number of positive isolates.  相似文献   

4.
The recovery of low numbers of Escherichia coli O157 in foods by immunomagnetic separation (IMS) was improved, on average, ninefold by increasing the enrichment volume tested from 1 to 10 ml while maintaining the volume of immunobeads constant at 0.02 ml. Although 50 ml volumes also gave improved recoveries (approximately threefold), the 50 ml volume cannot be recommended until a suitable magnetic separation apparatus has been developed. By testing 10 ml volumes, the improved sensitivity of the IMS procedure will reduce false-negative E. coli O157 tests and help improve epidemiological studies of this pathogen.  相似文献   

5.
AIMS: To compare a range of enrichment broths and enrichment temperatures for the isolation of Escherichia coli O157 by immunomagnetic separation (IMS) from sandy, loam and clay soils. METHODS AND RESULTS: Soils were spiked with cocktails of four atoxigenic strains of E. coli O157 and four strains of commensal E. coli. The organisms were stressed by subjecting soils to cycles of freeze/thawing, followed by drying at 20 degrees C for up to 4 days. Nine enrichment broths were trialled based on buffered peptone water, tryptone soya broths and EC broths supplemented with a range of selective additions. Enrichments were incubated for 6 h and assessed by target recovery after IMS on cefixime tellurite sorbitol MacConkey agar (CTSMAC) incubated at 37 degrees C for 24 h. A comparison of enrichment temperatures (37 and 42 degrees C) was also performed. Buffered peptone water (with or without vancomycin) and tryptone soya broth (with or without novobiocin) gave significant increases in recovery of E. coli O157 compared to others tested. In addition, broths incubated at 42 degrees C were superior to those at 37 degrees C for the recovery of E. coli O157. SIGNIFICANCE AND IMPACT OF THE STUDY: This study showed that sub-lethally damaged E. coli O157 surviving in soil can be sensitive to antimicrobial additions. The choice and concentration of these additions is vitally important to optimize target recovery. Some IMS protocols, established for the isolation of E. coli O157, may be unsuitable for the examination of soil samples.  相似文献   

6.
AIMS: To improve the sensitivity of a monoclonal antibody (MAb 2F3) based enteropathogenic Escherichia coli (EPEC)/enterohaemorrhagic E. coli (EHEC) serogroup O26-specific sandwich ELISA (sELISA), using a capture/enrichment format of the assay. METHODS AND RESULTS: The sELISA utilized an EPEC/EHEC O26-specific MAb 2F3 as the capture reagent and an E. coli serogroup O26 lipopolysaccharide-specific polyclonal antibody in the development stage. Wells containing faeces test samples from bovine enteritis cases and agar colony sweep cultures from human diarrhoea cases, after a 2-h capture stage, were washed and enrichment of the captured cells was encouraged by addition of tryptone soya broth. After overnight incubation, the contents of each well were transferred to sterile wells and the sELISA completed. Any sELISA positive samples were then subcultured onto blood agar to recover and further characterize the positive cultures. The assay had a sensitivity of 10(3) CFU ml(-1). ELISA positive samples consisted of 21 (4.8%) of the 442 bovine and 19 (3.7%) of the 519 human samples tested, and ELISA positive EPEC/EHEC O26 strains were isolated from 11 and three of these samples respectively. CONCLUSION: The capture/enrichment method improved the sensitivity of a MAb-based sELISA for the detection of EPEC/EHEC O26 strains, and also contributed to an improved isolation rate of the organism from field samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The application of a specific MAb in a capture/enrichment format of the sELISA, provides a prospectively suitable screening method for the detection of pathogenic bacteria from mixed culture samples.  相似文献   

7.
Cattle are considered the major reservoir for Escherichia coli O157:H7, one of the newly emerged foodborne human pathogens of animal origin and a leading cause of haemorrhagic colitis in humans. A sensitive test that can accurately and rapidly detect the organism in the food animal production environment is critically needed to monitor the emergence, transmission, and colonization of this pathogen in the animal reservoir. In this study, a novel multiplex polymerase chain reaction (PCR) assay was developed by using 5 sets of primers that specifically amplify segments of the eaeA, slt-I, slt-II, fliC, rfbE genes, which allowed simultaneous identification of serotype O157:H7 and its virulence factors in a single reaction. Analysis of 82 E. coli strains (49 O157:H7 and 33 non-O157:H7) demonstrated that this PCR system successfully distinguished serotype O157:H7 from other serotypes of E. coli and provided accurate profiling of the shiga-like toxins and the intimin adhesin in individual strains. This multiplex PCR assay did not cross-react with the background bacterial flora in bovine faeces and could detect a single O157:H7 organism per gram of faeces when combined with an enrichment step. Together, these results indicate that the multiplex PCR assay can be used for specific identification and profiling of E. coli O157:H7 isolates, and may be applied to rapid and sensitive detection of E. coli O157:H7 in bovine faeces when combined with an enrichment step.  相似文献   

8.
AIM: To quantify the effect of enrichment, immunomagnetic separation (IMS), and selective plating procedures on isolation of Shiga-toxigenic Escherichia coli O157 (STEC O157) and non-Shiga-toxigenic Escherichia coli O157 (non-STEC O157) from naturally contaminated bovine faeces. METHODS AND RESULTS: Two broth enrichment times, two IMS strategies, and two selective plating media were evaluated. STEC O157 and non-STEC O157 strains were often isolated from the same faecal specimen and responded differently to the isolation protocols. A large-volume IMS system was more sensitive than a conventional small-volume IMS method, but was also more expensive. STEC O157 was more frequently isolated from 6 h enriched broth and ChromAgar plates containing 0.63 mg l(-1) potassium tellurite (TCA). Non-STEC O157 was more frequently isolated from un-enriched broth and ChromAgar plates without tellurite (CA). CONCLUSIONS: The combination of 6-h enrichment in Gram-negative broth containing vancomycin, cefixime and cefsuludin, large volume IMS and selective plating on TCA maximized STEC O157 recovery from naturally contaminated cattle faecal specimens. SIGNIFICANCE AND IMPACT OF THE STUDY: The pairing of proper enrichment with a specific plating procedure is key for STEC O157 recovery from naturally contaminated bovine faeces. Incorporating tellurite into an E. coli O157 detection strategy may select for the subset of E. coli O157 that contains the Shiga-toxin genes.  相似文献   

9.
Immunoliposome sandwich assay for the detection of Escherichia coli O157:H7   总被引:5,自引:0,他引:5  
We describe the development of a field-portable colorimetric immunoassay for the detection of Escherichia coli O157:H7, using antibody-directed liposomes (immunoliposomes) encapsulating dye as an analytical reagent. Antibodies (anti-E. coli O157:H7) thiolated by 2-iminothiolane were coupled to malemide-tagged liposomes encapsulating the marker dye, sulforhodamine B. Transmission electron microscopy showed that the immunoliposomes bound only to the serotype without any cross-reactivity with tested negative controls. A wicking reagent containing immunoliposomes and the test sample and a plastic-backed nitrocellulose strip with a measurement zone were used in a sandwich (noncompetitive) assay format. During the capillary migration of the wicking reagent, E. coli, with surface-bound immunoliposomes, was captured at the measurement zone on which antibodies to E. coli O157:H7 were immobilized. The color density of the measurement zone was directly proportional to the amount of E. coli O157:H7 in the sample. The detection limit of the current assay with pure cultures of the serotype was ca. 10(4) colony-forming units (CFU)/mL. The assay, which does not need washing and incubation steps, can be completed in 8 min. These results demonstrate the feasibility of using dye-encapsulating immunoliposomes in microporous membranes for the rapid detection of molecules with multivalent antigenic sites.  相似文献   

10.

Background

Rapid transmission and high mortality of Ebola virus disease (EVD) highlight a urgent need of large scale, convenient and effective measure for Ebola virus screening. Application of monoclonal antibodies (mAbs) are crucial for establishment of an enzyme-linked immunosorbent assay (ELISA) with high sensitivity and specificity.

Methods

The traditional cell fusion technique was used to generate a panel of hybridomas. Two mAbs were characterized by SDS-PAGE, Western blot, Indirect immunofluorescence assay (IFA). A sandwich ELISA was established using the two mAbs. The detection capability of the ELISA was evaluated.

Results

In the current study, we produced two murine-derived mAbs (designated as 6E3 and 3F21) towards Zaire Ebola virus glycoprotein (GP), the major viral transmembrane spike protein associated with viral attachment. It was shown that 6E3 and 3F21 recognized GP1 and GP2 subunits of the GP respectively. Furthermore, 6E3 and 3F21 bound to corresponding epitopes on GP without reciprocal topographical interpretation. Subsequently, a sandwich ELISA based on the two mAbs were established and evaluated. The detection limit was 3.6?ng/ml, with a linear range of 3.6–100?ng/ml. More importantly, Ebola virus like particles (eVLPs) were able to be detected by this established virus detection measure.

Conclusions

We produced and characterized two murine-derived mAbs (designated as 6E3 and 3F21) towards Zaire Ebola virus glycoprotein (GP), and established a sandwich ELISA based on the mAbs. It was suggested that the sandwich ELISA provided an alternative method for specific and sensitive detection of Ebola virus in the field setting.
  相似文献   

11.
AIM: To develop and validate a direct plating method applicable to epidemiological studies for enumerating Escherichia coli O157 in cattle faeces. METHODS AND RESULTS: The spiral plate count method was used to enumerate E. coli O157 in faecal samples. The accuracy and variation of counts was then assessed using faecal samples inoculated with E. coli O157. There was good agreement between inoculated levels of E. coli O157 and those recovered from faeces, particularly when counts were > 10(2) CFU g(-1) of faeces. The method was applied to a small study assessing short-term survival of E. coli O157 in naturally infected cattle faeces. E. coli O157 was found to survive in faeces for over 10 days at concentrations above 10(3) CFU g(-1) of faeces. Populations of E. coli O157 were also found to increase 100-fold in the first few hours after defecation. CONCLUSIONS: The enumeration method is easy to implement and enables a quick throughput of large numbers of samples. The method is accurate and reliable and enables the inherent variation in count data to be explored but needs to be used in combination with a more sensitive method for samples containing < 10(2) CFU g(-1) of faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: The method described is appropriate for enumeration of E. coli O157 in cattle faeces in large-scale epidemiological studies.  相似文献   

12.
We found effective enrichment procedures for detecting Escherichia coli O26 in foods using methods that are used for E. coli O157. Ground beef or radish sprouts inoculated with approximately 6 colony-forming units of E. coli O26 were homogenized in 225 ml of various broths. After static incubation at 37 degrees C or 42 degrees C for 6 h or 18 h, we isolated the inoculated bacterium by plating onto Rainbow Agar O157 with novobiocin. In combination with the immunomagnetic separation method, E. coli O26 was isolated from all samples by using enrichment in tryptone soy broth at 37 degrees C for 6 h and in modified E. coli broth with novobiocin (mEC + n) at 42 degrees C for 18 h in ground beef and radish sprouts, respectively. Enrichment in mEC + n at 42 degrees C for 18 h was effective for isolating both E. coli O26 and E. coli O157 from both ground beef and radish sprouts.  相似文献   

13.
AIMS: To determine the numbers of Escherichia coli O157 present in the faeces of naturally infected cattle. METHODS AND RESULTS: A combination of the most probable number (MPN) technique and automated immunomagnetic separation (AIMS) was used to enumerate E. coli O157 in cattle faeces from both pasture-fed and grain-fed animals. A total of 22 E. coli O157 positive faecal samples were enumerated for E. coli O157 (10 from pasture-fed and 12 from grain-fed animals). The numbers of E. coli O157 in cattle faeces varied from undetectable (<3 MPN g-1 of faeces) to 2.4 x 104 MPN g-1. There was no significant difference (P = 0.06) between the numbers of E. coli O157 in pasture-fed or grain-fed cattle faeces, although the geometric mean (antilog of the mean of log10 transformed MPN values) was higher in grain-fed (130 MPN g-1) than in pasture-fed (13 MPN g-1). CONCLUSIONS: Although the number of samples tested is small, the results indicate that E. coli O157 make up a small proportion of the total E. coli population present in cattle faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: Information on the numbers of E. coli O157 present in cattle will assist in developing more robust quantitative risk assessments and formulating intervention strategies.  相似文献   

14.
A protocol for the quantitative detection of Escherichia coli O157 in raw and concentrated surface waters using immunomagnetic electrochemiluminescence (IM-ECL) was developed and optimized. Three antibody sandwich formats were tested: commercial anti-O157:H7 IM beads, IM beads made in-house with a polyclonal anti-O157:H7 immunoglobulin G (IgG), or IM beads made in-house with a monoclonal anti-O157:H7 IgG coupled with a polyclonal anti-O157:H7 IgG to which an electrochemiluminescent label (TAG) was attached. The monoclonal IM bead-polyclonal TAG format was chosen for optimization because it gave lower background levels and linear regression slopes of ca. 1.0, indicative of a constant ECL signal per cell. The dynamic range was ca. 10(1) to 10(5) cells ml(-1) in phosphate-buffered saline and in raw water samples. The monoclonal IM beads selectively captured E. coli O157 cells in the presence of ca. 10(8) cells of a non-O157 strain of E. coli ml(-1). Background ECL signals from concentrated (100-fold) water samples were substantially higher and more variable than raw water samples. The background signal was partially eliminated by the addition of polyvinylpolypyrrolidone. Successive cell capture incubations, termed sequential bead capture (SBC), were optimized for establishing baseline ECL values for individual water samples. The linear dynamic range with SBC was ca. 10(2) to 10(5) E. coli O157 cells ml of concentrated water(-1). To validate the protocol, 10-liter surface water samples were spiked with ca. 5,000 E. coli O157 (Odwalla) cells and concentrated by vortex filtration, and 1- or 3-ml aliquots were analyzed by IM-ECL. Differential ECL signals (SBC) from 1- and 3-ml samples were statistically significant and were generally consistent with standard curves for these cell concentrations. Enrichments were conducted with aliquots of spiked raw water and concentrated water using EC broth and minimal lactose broth (MLB). All tubes with concentrated water became turbid and gave a positive ECL response for E. coli O157 (>10,000 ECL units); MLB gave a somewhat higher detection rate with spiked raw water. The potential sensitivity of the IM-ECL assay is ca. 25 E. coli O157 cells ml of raw water(-1), 25 cells 100 ml of 100-fold concentrated water(-1), or 1 to 2 viable cells liter(-1) with concentration and enrichment. The IM-ECL assay appears suitable for routine analysis and screening of water samples.  相似文献   

15.
A.R. BENNETT, S. MACPHEE AND R.P. BETTS. 1996. The use of immunomagnetic separation (IMS) techniques has been reported to reduce the total test time, and improve the sensitivity, of microbiological tests done on foods. This approach is being adopted in epidemiological investigations into suspected foodborne outbreaks of Escherichia coli O157 infection and has gained acceptance by public health laboratories and the food industry. This study demonstrated the ability of a commercially available IMS procedure, Dynabeads anti- E. coli O157, to enable detection of a few cells of E. coli O157 in 25 g of inoculated minced beef, giving results 1 d earlier than a cultural analysis of similar sensitivity. With correct choice of enrichment broths, IMS may increase isolation rate of E. coli O157 compared to that obtained using conventional cultural methods. It is suggested that this may be due to an increase in relative concentration of E. coli O157 compared with the background microflora present in minced beef, which may reduce reliability of non-IMS detection procedures by masking or mimicking target cells on selective/differential solid media. The use of an immunoassay incorporating an IMS step, EHEC-Tek (Organon-Teknika), enabled detection of a few cells of E. coli O157 in 25 g of minced beef. Comparison of the IMS-ELISA with a standard ELISA procedure (Tecra) indicated the sensitivity of the latter system to be greater, perhaps resulting in the higher isolation rate. The use of a method to reliability isolate and detect extremely low levels of E. coli O157 in a food is necessary to aid reduction in the incidence of this most serious of foodborne pathogens.  相似文献   

16.
Detection of Escherichia coli O157:H7 organisms in food, clinical or environmental samples is necessary for diagnosis of infection and epidemiological investigations. However, this pathogen may be present in low numbers and difficult to identify among high numbers of other background bacteria. In order to increase the sensitivity of culture- and PCR detection, pre-enrichment of E. coli O157:H7 in broth culture combined with ImmunoMagnetic cell Separation (IMS) is routinely employed. These methods, although able to detect levels as low as 2 cfu/g (from 10 to 25 g samples), are qualitative detection strategies only. If the actual numbers of E. coli O157:H7 are to be quantified, growth enrichment must be excluded and the organisms isolated directly from the sample of interest. Such quantification is necessary, for example, to determinate contamination levels on beef carcasses and for determination of bacterial numbers in in vivo gene expression studies. In the present study, it was not possible to recover organisms from bovine faecal suspensions using the customary IMS system and so a range of alternative buffers and other paramagnetic beads was tested. Combination of a 6.2-microm diameter bead with a detergent-based buffer gave optimal recovery of E. coli O157:H7 organisms from faecal suspensions. This system was validated for recovery of E. coli O157:H7 by comparing it with that obtained with the standard Dynabeads IMS protocol, using both the traditional broth enrichment method and a quantitative detection approach. We conclude that a 6.2-microm diameter Aureon bead can be used for quantitative isolation of E. coli O157:H7 directly from bovine faeces and, for this purpose, is preferred to the 2.8-microm diameter Dynal bead.  相似文献   

17.
A commercial enzyme immunoassay (EIA) (E. coli O157 Visual Immunoassay; Tecra Diagnostics) performed on enrichment cultures in modified Escherichia coli broth (mECn) was compared with immunomagnetic separation (IMS) (Dynabeads anti-E. coli O157; Dynal) performed on enrichment cultures in modified buffered peptone water (BPW-VCC) for the detection of E. coli O157 in bovine fecal samples. Tests on fecal suspensions inoculated with each of 12 different strains of E. coli O157 showed that both the EIA and IMS methods were 10- to 100-fold more sensitive than direct culture or enrichment subculture methods for detection of the organism. EIA and IMS were then compared for detection of E. coli O157 in bovine rectal swabs. For confirmation of positive EIA tests, a commercial system (Immunocapture System [ICS]; Tecra Diagnostics) was compared with IMS; both were performed on mECn enrichment cultures. Of 200 rectal swabs examined, 17 gave positive results in the EIA which were confirmed by both confirmation systems, 2 gave positive results in the EIA which were confirmed by IMS but not by ICS, and 1 gave a positive result in the EIA which was confirmed by ICS but not by IMS. Of these 20, 15 were also positive by the BPW-VCC-IMS culture system; a further 3 samples were positive by this culture system but gave a negative result in the EIA. Eight samples were negative by the BPW-VCC-IMS culture system but gave a positive result in the EIA which could not be confirmed by either confirmation system. Further examination of the eight unconfirmed EIA-positive samples yielded sorbitol-fermenting E. coli O157 from three samples. Of the remaining five cultures, four were positive in an EIA for verocytotoxins (VT) and two were positive in a cell culture assay for VT1. The remaining 170 samples were negative by both EIA and BPW-VCC-IMS. The Tecra EIA and IMS are both technically simple and sensitive methods for detecting E. coli O157 in bovine fecal samples. There was no statistically significant difference between the numbers of positives detected by the different assays (P = 0.29).  相似文献   

18.
AIMS: The aim of this study was to isolate Escherichia coli O26, O103, O111 and O145 from 745 samples of bovine faeces using (i) immunomagnetic separation (IMS) beads coated with antibodies to lipopolysaccharide, and slide agglutination (SA) tests and (ii) PCR and DNA probes for the detection of the Verocytotoxin (VT) genes. METHODS AND RESULTS: IMS-SA tests detected 132 isolates of presumptive E. coli O26, 112 (85%) were confirmed as serogroup O26 and 102 had the VT genes. One hundred and twenty-two strains of presumptive E. coli O103 were isolated by IMS-SA, 45 (37%) were confirmed as serogroup O103 but only one of these strains was identified as Verocytotoxin-producing E. coli (VTEC). Using the PCR/DNA probe method, 40 strains of VTEC O26 and three strains of VTEC O103 were isolated. IMS-SA identified 21 strains of presumptive E. coli O145, of which only four (19%) were confirmed as serogroup O145. VTEC of this serogroup was not detected by either IMS-SA or PCR/DNA probes. E. coli O111 was not isolated by either method. CONCLUSION: IMS beads were 2.5 times more sensitive than PCR/DNA probe methods for the detection of VTEC O26 in bovine faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: IMS-SA is a sensitive method for detecting specific E. coli serogroups. However, the specificity of this method would be enhanced by the introduction of selective media and the use of tube agglutination tests for confirmation of the preliminary SA results.  相似文献   

19.
AIMS: To compare media used in immunomagnetic separation (IMS) techniques for the isolation of Escherichia coli O157 from food. METHODS AND RESULTS: Foods, both naturally contaminated and spiked, with low numbers (< 1 g(-1)) of stressed E. coli O157 were enriched in media based on buffered peptone water (BPW), tryptone soya and EC broths incubated at 30, 37, 40 and 42 degrees C. Following immunomagnetic separation, beads were plated on a range of selective agars. CONCLUSION: BPW supplemented with vancomycin (8 mg l(-1)) incubated at 42 degrees C, followed by IMS and subsequent plating of immunobeads onto cefixime tellurite sorbitol MacConkey agar plus either Rainbow or CHROMagar agars, proved optimum for the recovery of spiked, stressed E. coli O157 in minced beef, cheese, apple juice and pepperoni. The same protocol was optimum for recovery from naturally-contaminated minced beef and cheese. SIGNIFICANCE AND IMPACT OF THE STUDY: The optimum protocol would increase isolation rates of E. coli O157 from foods.  相似文献   

20.
Contamination of fresh produce with Escherichia coli O157:H7 and other pathogens commonly causes food-borne illness and disease outbreaks. Thus, screening for pathogens is warranted, but improved testing procedures are needed to allow reproducible same-day detection of low initial contamination levels on perishable foods, and methods for detecting numerous pathogens in a single test are desired. Experimental procedures were developed to enable rapid screening of spinach for E. coli O157:H7 by using multiplex-capable immunological assays that are analyzed using biosensors. Detection was achieved using an automated electrochemiluminescent (ECL) assay system and a fluorescence-based cytometric bead array. Using the ECL system, less than 0.1 CFU of E. coli O157:H7 per gram of spinach was detected after 5 h of enrichment, corresponding to 6.5 h of total assay time. Using the cytometric bead array, less than 0.1 CFU/g was detected after 7 h of enrichment, with a total time to detection of less than 10 h. These results illustrate that both biosensor assays are useful for rapid detection of E. coli O157:H7 on produce in time frames that are comparable to or better than those of other testing formats. Both methods may be useful for multiplexed pathogen detection in the food industry and other testing situations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号