首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A stereospecific method of analysis of racemic isosakuranetin (5,7-dihydroxy-4'-methoxyflavanone) in biological fluids is necessary to study pharmacokinetics. A simple high-performance liquid chromatographic method was developed for the determination of isosakuranetin enantiomers. Separation was achieved on a Chiralpak AD-RH column with ultraviolet (UV)-detection at 286 nm. The standard curves in urine were linear ranging from 0.5 to 100.0 microg/ml for each enantiomer. The mean extraction efficiency was >88.0%. Precision of the assay was <15% (CV) and was within 12% at the limit of quantitation (0.5 microg/ml). Bias of the assay was <15% and was within 6% at the limit of quantitation. The assay was applied successfully to stereospecific disposition of isosakuranetin enantiomers in rat urine.  相似文献   

2.
A stereoselective liquid chromatography-tandem mass spectrometry assay was developed and validated for quantification of S- and R-metoprolol at concentrations of 0.5-50 microg/L in human plasma. Metoprolol was extracted from plasma by liquid-liquid extraction with ethyl acetate (82% recovery). Chromatographic separation of the enantiomers was achieved on a chiral Chirobiotic T column using an isocratic mobile phase consisting of methanol/acetic acid/ammonia (100/0.15/0.15, v/v/v). An ion trap mass spectrometer with an electrospray interface was used for detection in the positive mode, monitoring the m/z transition 268-->191 for metoprolol. Standard curves for S- and R-metoprolol fitted quadratic functions (r(2)>or=0.9995) over the range 0.5-50 microg/L in plasma, with 0.5 microg/L representing the limit of quantification. In this range, relative standard deviations were <6% for intra-day precision and <10% for inter-day precision. The accuracy was within the range of 92-105%.  相似文献   

3.
A sensitive gas chromatography-mass spectrometry method for measuring propofol in cerebrospinal fluid is described, validated and applied to four patients after traumatic brain injury. The limit of quantitation was 2 microg/L using a volume of 0.5 mL. The inter- and intra-assay coefficients of variation were 5.9 and 5.1%, respectively. The assay covers the linear concentration range of 2-50 microg/L, which is relevant in clinical pharmacokinetic studies when propofol is used in the Intensive Care Unit as a sedative agent or to lower the intracranial pressure.  相似文献   

4.
A sensitive assay for the determination of unbound ertapenem in human plasma and bronchoalveolar lavage (BAL) was developed using ultrafiltration of plasma and BAL samples. A rapid HPLC method was used with ultraviolet detection set at a wavelength of 305 nm and a separation on a Prontosil AQ C18 column, with imipenem used as internal standard. This assay was linear over the concentration range of 0.5-100 microg/mL and 0.25-50 microg/mL in plasma and BAL, respectively. Limits of detection and quantitation were respectively 0.05 and 0.25 microg/mL. Validation data for accuracy and precision were CV<2.48 and 8.25%, accuracy in the range 98.1-104.2% and 102.2-108.4%, respectively, for intra and inter-day.  相似文献   

5.
A liquid chromatography-mass spectrometry (LC/MS) assay method was developed for the quantification of PSC 833 in rat plasma, using amiodarone as internal standard (IS). Separation was achieved using a C(8) 3.5 microm (2.1 mm x 50 mm) column heated to 60 degrees C with a mobile phase consisting of acetonitrile-ammonium hydroxide 0.2% (90:10 v/v) pumped at a rate of 0.2 mL/min. Detection was accomplished by mass spectrometer using selected ion monitoring (SIM) in positive mode. An excellent linear relationship was present between peak height ratios and rat plasma concentrations of PSC 833 ranging from 10 to 5000 ng/mL (R(2)>0.99). Intra-day and inter-day coefficients of variation (CV%) were less than 15%, and mean error was less than 10% for the concentrations above the limit of quantification. The validated limit of quantification of the assay was 10 ng/mL based on 0.1 mL rat plasma. The method limit of detection, based on an average signal-to-noise (S/N) ratio of 3, was found to be 2.5 ng/mL. The assay was capable of measuring the plasma concentrations of PSC 833 in rats injected with a single dose of 5 mg/kg of the drug. PSC 833 and IS eluted within 4 min, free of interfering peaks. The method was found to be fast, sensitive, and specific for the quantification of PSC 833 in rat plasma.  相似文献   

6.
To support animal studies and clinical pharmacokinetic trials, we developed and validated an automated, specific and highly sensitive LC-MS/MS method for the quantification of naltrexone and 6beta-naltrexol in the same run. In human plasma, the assay had a lower limit of quantitation of only 5pg/mL. This was of critical importance to follow naltrexone pharmacokinetics during its terminal elimination phase. The assay had the following key performance characteristics for naltrexone in human plasma: range of reliable quantification: 0.005-100ng/mL (r2>0.99), inter-day accuracy (0.03ng/mL): 103.7% and inter-day precision: 10.1%. There were no ion suppression, matrix interferences or carry-over.  相似文献   

7.
A rapid and simple high-performance liquid chromatographic method for the determination of the R-(-)- and S-(+)-enantiomers of the antiepileptic drug vigabatrin in human plasma is described. After adding the internal standard (1-aminomethyl-cycloheptyl-acetic acid), plasma samples (200 microL) are deproteinized with acetonitrile and the supernatant is derivatized with 2,4,6 trinitrobenzene sulfonic acid (TNBSA). Separation is achieved on a reversed-phase cellulose-based chiral column (Chiralcel-ODR, 250 mm x 4.6 mm i.d.) using 0.05 M potassium hexafluorophosphate (pH 4.5)/acetonitrile/ethanol (50:40:10 vol/vol/vol) as mobile phase at a flow-rate of 0.9 mL/min. Chromatographic selectivity is improved by concentrating the derivatives on High Performance Extraction Disk Cartridges prior to injection. Detection is at 340 nm. Calibration curves are linear (r(2)> or =0.999) over the range of 0.5-40 microg/mL for each enantiomer, with a limit of quantification of 0.5 microg/mL for both analytes. The assay is suitable for therapeutic drug monitoring and for single-dose pharmacokinetic studies in man.  相似文献   

8.
A liquid chromatography-mass spectrometry (LC-MS) method was developed for the analysis of vancomycin (VCM) in human serum. The method was based on full scan data with extracted ions for the accurate masses of VCM and the atenolol internal standard obtained by Fourier transform MS. VCM was extracted from serum using strong cation exchange (SCX) solid phase extraction (SPE). The method was found to be linear in the range 0.05-10 microg/ml, which was adequate for quantification of VCM in serum samples, with a limit of quantification (LOQ) of 0.005 microg/ml and a limit of detection (LOD) of 0.001 microg/ml. Intra-day precision (n=5) was +/-3.5%, +/-2.5%, +/-0.7% at 0.05, 0.5 and 5 microg/ml, respectively. Inter-day precision (n=5) was +/-7.6%, +/-6.4%, +/-3.9% at 0.05, 0.5 and 5 microg/ml, respectively. The process efficiency for VCM was in the range 89.2-98.1% with the recovery for the atenolol internal standard (IS) being 97.3%. The method was used to determine VCM levels in patients during peri-operative infusion of the drug, which was found to result in drug levels within the required therapeutic window.  相似文献   

9.
A sensitive stereospecific high-performance liquid chromatographic assay for the quantification of tiaprofenic acid in human plasma was developed. The procedure involved extraction of tiaprofenic acid from acidified plasma into hexane-diethyl ether (8:2, v/v). Stereospecific separation was achieved with a prepacked ga1-acid glycoprotein column without derivatization. The mobile phase consisted of 2% 2-propanol in 0.01 M phosphate buffer, pH 6.5. Tiaprofenic acid was detected at 317 nm. The limit of quantification was found to be 25 ng/ml for each enantiomer using a 0.5 ml plasma sample. The assay was reproducible and accurate to be applied to the stereoselective pharmacokinetic analysis of tiaprofenic acid in plasma. Because of photoinstability of tiaprofenic acid plasma sampling and sample extraction should be performed under light protection.  相似文献   

10.
A rapid and simple method was developed for the simultaneous separation and quantification of cloricromene, a coumarine derivative, and its active metabolite, cloricromene acid, in rabbit aqueous humor. The analyses were performed by high-performance liquid chromatography using a C18 reversed-phase column (Hypersil ODS) with UV detection at 318 nm. The mobile phase consisted of acetonitrile-water containing 1% triethylamine pH 3.5, adjusted with orthophosphoric acid. An acetonitrile gradient was necessary to achieve good separation within 13 min. Timolol was found to be a suitable internal standard. The retention times ranged from 5.72 to 11.25 min. A simple pre-treatment with acetonitrile containing 0.6% HCIO4 was used to deproteinize aqueous humor samples. The limit of quantitation ranged between 10 and 20 ng/ml. The recovery was >90%. The relationship between peak areas and concentration was linear over the range between 0.01 and 3.8 microg/ml, with r2 > 0.99. The assay provided good reproducibility and accuracy for both analytes and proved to be suitable for pharmacokinetic studies of cloricromene.  相似文献   

11.
Sodium tanshinone IIA sulfonate (STS), a hydrophilic ionic substance, is used as a cardiovascular drug. An ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC) method for the determination of STS in mouse plasma was initially developed. The assay involved a rapid and simple extraction process and subsequent detection at 271 nm. The retention time for STS was 7.5 min. Based on extracted STS standard mouse plasma at 1.5,10 and 50 microg/ml, the assay precision were 2.7, 2.1 and 1.7% with a mean accuracy of 96.7, 98.5 and 99.4%, respectively. At plasma concentration of 1.5, 50 and 75 microg/ml, the mean recovery of STS were 93.1, 96.3 and 97.5%. The limit of detection (LOD) and limit of quantification (LOQ) for STS was 0.1 microg/ml and 0.5 microg/ml, respectively. Linear responses were observed over a wide concentration range (0.5-100 microg/ml) for STS in mouse plasma. STS can be detected after intravenous administration. This method was performed for the first time in pharmacokinetic studies of STS in the mouse.  相似文献   

12.
A sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) assay with on-line extraction was developed for quantifying ertapenem in human cerebrospinal fluid (CSF). This assay is at least five times more sensitive than previously published ertapenem methods with a lower limit of quantitation at 0.025 microg/ml. In this assay, a CSF sample is extracted on-line using a RP extraction column and an aqueous acidic mobile phase (0.1% formic acid) to wash away polar endogenous materials, while ertapenem is retained on the column. Ertapenem is then back-flushed off the extraction column and directed to a RP analytical column using an acidic mobile phase with an organic modifier (acetonitrile/0.1% formic acid, 15:85 (v/v)) and detected using UV absorbance. The acidic mobile phase provided a sharper chromatographic peak and on-line extraction allowed large injection volumes (> or = 150 microl) of buffered CSF to be injected without compromising column integrity. These assay conditions were necessary to quantify ertapenem at levels expected to be found in human CSF (< 0.05 microg/ml). The method was successfully validated and implemented for a clinical study: intraday precision and accuracy of the CSF assay for calibration standards (0.025-10 microg/ml) and quality control samples (0.1, 0.5, and 2.5 microg/ml) were < 6.2% coefficient of variation and 96.8-104.0% of nominal concentration, respectively.  相似文献   

13.
Urinary kidney injury molecule (KIM-1) is a sensitive quantitative biomarker for early detection of kidney tubular injury. The objective of the present work was to analytically validate this urinary renal injury biomarker. Duo-set reagents from R&D were used to develop the ELISA and validate the assay's linearity, intra-run precision, inter-run precision, lower limit of quantification, recovery, dilutional verification, reference range, stability, and length of run. The reference range data suggests that the healthy population falls within the assay range (59 - 2146 pg/mL) and upper limit of quantitation for this assay is 17168 pg/mL for the patient population. This is a robust assay to detect urinary levels of KIM-1, which serves as a non-invasive sensitive, reproducible, and potentially high-throughput method to detect early kidney injury in drug development studies.  相似文献   

14.
A simple and sensitive HPLC method has been developed and validated for the determination of oridonin (ORI) in rabbit plasma. A simple liquid-liquid extraction (LLE) method was applied to extract ORI and the internal standard (IS), isopsoralen, from rabbit plasma. Chromatographic separation of ORI and the IS was achieved with a Kromasil C18 5-mum column (250 mm x 4.6 mm) using methanol-water (50:50, v/v) as mobile phase at a flow rate of 1 mL/min. The ultraviolet (UV) detection wavelength was set at 241 nm. The lower limit of quantification (LLOQ) was 0.02 microg/mL. The calibration curves were linear over a concentration range of 0.02-10 microg/mL. The assay accuracy and precision were within the range of 95.1-113.5% and 5.4-8.6%, respectively. This HPLC method was applied successfully to the pharmacokinetic study of ORI-loaded poly(caprolactone)-poly(ethylene oxide)-poly(caprolactone) copolymer nanoparticles (ORI-PCL-PEO-PCL-NP) in rabbits, given as a single intravenous injection at the dose equivalent to 2mg of ORI/kg, and the pharmacokinetic parameters for ORI were compared with a single intravenous injection of a ORI solution at the same dose.  相似文献   

15.
A rapid and simple HPLC assay was developed for the determination of celecoxib in human plasma and breast milk. After proteins were precipitated with acetonitrile, celecoxib was resolved on a C18 column and detected by UV detection at 254 nm. Standard curves were linear over the concentration range 10-2000 microg/L (r(2)>0.99). Bias was 相似文献   

16.
A stereospecific method for simultaneous quantitation of the enantiomers of tramadol (T) and its active metabolites O-demethyl tramadol (M1) and O-demethyl-N-demethyl tramadol (M5) in human plasma is reported. After the addition of penbutolol (IS), plasma (0.5 ml) samples were extracted into methyl tert-butyl ether, followed by back extraction into an acidic solution. The separation was achieved using a Chiralpak AD column with a mobile phase of hexanes:ethanol:diethylamine (94:6:0.2) and a flow rate of 1 ml/min. The fluorescence of analytes was then detected at excitation and emission wavelengths of 275 and 300 nm, respectively. All the six enantiomeric peaks of interest plus three unknown metabolite peaks and IS peak (a total of 10 peaks) eluted within 23 min, free from endogenous interference. The assay was validated in the plasma concentration range of 2.5-250 ng/ml, with a lower limit of quantitation of 2.5 ng/ml, for all the six analytes. The extraction efficiency (n=5) was close to 100% for both T and M1 enantiomers and 85% for M5 and IS enantiomers. The application of the assay was demonstrated by simultaneous measurement of plasma concentrations of T, M1, and M5 enantiomers in a healthy volunteer after the administration of 50 mg oral doses of racemic T.  相似文献   

17.
A simple, rapid and reliable method was developed for the identification and quantification of helicidum and its metabolites in beagle dog plasma by liquid chromatography/ultra-violet/electrospray ionization-ion trap mass spectrometry (LC/UV/ESI-ITMS). Two metabolites were identified by MS: formylphenyl-O-beta-d-pyranosyl alloside (I) and hydroxylmethylphenyl-O-beta-d-pyranosyl alloside (II). UV was used for concentration determination with the wavelength of 270 nm. Liquid-liquid extraction was used and the extraction recovery exceeded 90%. Kromacil C(18) column (5 microm, 4.6mm i.d. x 250 mm) was used as the analytical column. Linear detection responses were obtained for helicidum concentration ranging from 1.76 x 10(-4) to 70.4 x 10(-4) micromol/mL (0.050-2.00 microg/mL). The precision and accuracy data, based on intra- and inter-day variations over 3 days, were less than 5%. The limit of determination and quantitation (LOD, LOQ) for helicidum was 0.010 and 0.030 microg/mL, respectively. Pharmacokinetic data of helicidum and the two metabolites were obtained with this method after administration of intravenous injection and a single oral dose of tablets to six beagle dogs, respectively.  相似文献   

18.
A simple liquid chromatography tandem mass spectrometry method was developed and validated according to the guidelines of the US Food and Drug Administration and the European Medicines Agency for a simultaneous quantification of levetiracetam (LEV) and its metabolite, UCB L057 in the plasma of patients. A 0.050 mL plasma sample was prepared by a simple and direct protein precipitation with 0.450 mL acetonitrile (ACN) containing 1 µg/mL of internal standard (IS, diphenhydramine), then vortex mixed and centrifuged. A 0.100 mL of the clear supernatant was diluted with 0.400 mL water and well mixed. A 0.010 mL of the resultant solution was injected into an Agilent Zorbax SB-C18 (2.1 mm×100 mm, 3.5 µm) column with an isocratic elution at 0.5 mL/min using a mixture of 0.1% formic acid in water and ACN (40∶60 v/v). Detection was performed using an AB Sciex API 3000 triple quadrupole mass spectrometer, equipped with a Turbo Ion Spray source, operating in a positive mode: LEV at transition 171.1>154.1, UCB L057 at 172.5>126.1, and IS at 256.3>167.3; with an assay run time of 2 minutes. The lower limit of quantification (LLOQ) for both LEV and UCB L057 was validated at 0.5 µg/mL, while their lower limit of detection (LOD) was 0.25 µg/mL. The calibration curves were linear between 0.5 and 100 µg/mL for both analytes. The inaccuracy and imprecision of both intra-assay and inter-assay were less than 10%. Matrix effects were consistent between sources of plasma and the recoveries of all compounds were between 100% and 110%. Stability was established under various storage and processing conditions. The carryovers from both LEV and UCB L057 were less than 6% of the LLOQ and 0.13% of the IS. This assay method has been successfully applied to a population pharmacokinetic study of LEV in patients with epilepsy.  相似文献   

19.
A novel flow injection chemiluminescence method for the determination of orciprenaline was developed. The method is based on the chemiluminescence (CL) reaction of orciprenaline with potassium ferricyanide in sodium hydroxide medium, sensitized by the fluorescent dye rhodamine 6G. The proposed procedure allows quantitation of orciprenaline in the concentration range 0.01-1.2 microg/mL, with a detection limit of 7.2 x 10(-3) microg/mL. The relative standard deviation (RSD) is 2.7% for 0.1 microg/mL orciprenaline (n = 9). The sampling frequency was calculated at approximately 120/h. The method was successfully applied to the determination of orciprenaline in pharmaceutical preparations. A brief discussion on the possible CL reaction mechanism is presented.  相似文献   

20.
Pralidoxime methylsulfate (Contrathion) is widely used to treat organophosphate poisoning. Despite animal and human studies, the usefulness of Contrathion therapy remains a matter of debate. Therapeutic dosage regimens need to be clarified and availability of a reliable method for plasma pralidoxime quantification would be helpful in this process. We here describe a high-performance liquid chromatography technique with electrochemical detection to measure pralidoxime concentrations in human serum using guanosine as an internal standard. The assay was linear between 0.25 and 50 microg mL(-1) with a quantification limit of 0.2 microg mL(-1). The analytical precision was satisfactory, with variation coefficients lower 10%. This assay was applied to the analysis of a serum from an organophosphorate poisoned patient and treated by Contrathion infusions (100 and 200 mg h(-1)) after a loading dose (400 mg).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号