首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Computed tomography (CT) is the standard imaging modality in radiation therapy treatment planning (RTP). However, magnetic resonance (MR) imaging provides superior soft tissue contrast, increasing the precision of target volume selection. We present MR-only based RTP for a rat brain on a small animal radiation research platform (SARRP) using probabilistic voxel classification with multiple MR sequences. Six rat heads were imaged, each with one CT and five MR sequences. The MR sequences were: T1-weighted, T2-weighted, zero-echo time (ZTE), and two ultra-short echo time sequences with 20 μs (UTE1) and 2 ms (UTE2) echo times. CT data were manually segmented into air, soft tissue, and bone to obtain the RTP reference. Bias field corrected MR images were automatically segmented into the same tissue classes using a fuzzy c-means segmentation algorithm with multiple images as input. Similarities between segmented CT and automatic segmented MR (ASMR) images were evaluated using Dice coefficient. Three ASMR images with high similarity index were used for further RTP. Three beam arrangements were investigated. Dose distributions were compared by analysing dose volume histograms. The highest Dice coefficients were obtained for the ZTE-UTE2 combination and for the T1-UTE1-T2 combination when ZTE was unavailable. Both combinations, along with UTE1-UTE2, often used to generate ASMR images, were used for further RTP. Using 1 beam, MR based RTP underestimated the dose to be delivered to the target (range: 1.4%-7.6%). When more complex beam configurations were used, the calculated dose using the ZTE-UTE2 combination was the most accurate, with 0.7% deviation from CT, compared to 0.8% for T1-UTE1-T2 and 1.7% for UTE1-UTE2. The presented MR-only based workflow for RTP on a SARRP enables both accurate organ delineation and dose calculations using multiple MR sequences. This method can be useful in longitudinal studies where CT’s cumulative radiation dose might contribute to the total dose.  相似文献   

2.
Using magnetic resonance imaging (MRI) as the sole imaging modality for patient modeling in radiation therapy (RT) is a challenging task due to the need to derive electron density information from MRI and construct a so-called pseudo-computed tomography (pCT) image. We have previously published a new method to derive pCT images from head T1-weighted (T1-w) MR images using a single-atlas propagation scheme followed by a post hoc correction of the mapped CT numbers using local intensity information. The purpose of this study was to investigate the performance of our method with head zero echo time (ZTE) MR images. To evaluate results, the mean absolute error in bins of 20 HU was calculated with respect to the true planning CT scan of the patient. We demonstrated that applying our method using ZTE MR images instead of T1-w improved the correctness of the pCT in case of bone resection surgery prior to RT (that is, an example of large anatomical difference between the atlas and the patient).  相似文献   

3.
Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disorder characterized by cortical and spinal motor neuron dysfunction. Routine magnetic resonance imaging (MRI) studies have previously shown hypointense signal in the motor cortex on T(2)-weighted images in some ALS patients, however, the cause of this finding is unknown. To investigate the utility of this MR signal change as a marker of cortical motor neuron degeneration, signal abnormalities on 3T and 7T MR images of the brain were compared, and pathology was obtained in two ALS patients to determine the origin of the motor cortex hypointensity. Nineteen patients with clinically probable or definite ALS by El Escorial criteria and 19 healthy controls underwent 3T MRI. A 7T MRI scan was carried out on five ALS patients who had motor cortex hypointensity on the 3T FLAIR sequence and on three healthy controls. Postmortem 7T MRI of the brain was performed in one ALS patient and histological studies of the brains and spinal cords were obtained post-mortem in two patients. The motor cortex hypointensity on 3T FLAIR images was present in greater frequency in ALS patients. Increased hypointensity correlated with greater severity of upper motor neuron impairment. Analysis of 7T T(2)(*)-weighted gradient echo imaging localized the signal alteration to the deeper layers of the motor cortex in both ALS patients. Pathological studies showed increased iron accumulation in microglial cells in areas corresponding to the location of the signal changes on the 3T and 7T MRI of the motor cortex. These findings indicate that the motor cortex hypointensity on 3T MRI FLAIR images in ALS is due to increased iron accumulation by microglia.  相似文献   

4.
Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI), play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO), with enhancement effects on both T1- and T2-weighted MR images of the liver. A 3.0T clinical MR scanner equipped with transmit/receiver coil for mouse was used to obtain both T1-weighted spoiled gradient-echo and T2-weighted fast spin-echo axial images of the liver before and after intravenous contrast agent injection into Balb/c mice with and without tumors. After pre-contrast scanning, six mice per group were intravenously injected with 0.1 mmol/kg Gd-MnMEIO, or the control agents, i.e., Gd-DTPA or SPIO. The scanning time points for T1-weighted images were 0.5, 5, 10, 15, 20, 25, and 30 min after contrast administration. The post-enhanced T2-weighted images were then acquired immediately after T1-weighted acquisition. We found that T1-weighted images were positively enhanced by both Gd-DTPA and Gd-MnMEIO and negatively enhanced by SPIO. The enhancement by both Gd-DTPA and Gd-MnMEIO peaked at 0.5 min and gradually declined thereafter. Gd-MnMEIO (like Gd-DTPA) enhanced T1-weighted images and (like SPIO) T2-weighted images. Marked vascular enhancement was clearly visible on dynamic T1-weighted images with Gd-MnMEIO. In addition, the T2 signal was significantly decreased at 30 min after administration of Gd-MnMEIO. Whereas the effects of Gd-MnMEIO and SPIO on T2-weighted images were similar (p = 0.5824), those of Gd-MnMEIO and Gd-DTPA differed, with Gd-MnMEIO having a significant T2 contrast effect (p = 0.0086). Our study confirms the feasibility of synthesizing an MR contrast agent with both T1 and T2 shortening effects and using such an agent in vivo. This agent enables tumor detection and characterization in single liver MRI sections.  相似文献   

5.
Calcium oxalate (CaOX) crystals and calcium hydroxyapatite (CaHA) crystals were commonly associated with breast benign and malignant lesions, respectively. In this research, CaOX (n = 6) and CaHA (n = 6) crystals in air-bubble-free agarose phantom were studied and characterized by using MRI at 9.4 T scanner. Calcium micro-crystals, with sizes that ranged from 200 to 500 µm, were made with either 99% pure CaOX or CaHA powder and embedded in agar to mimic the dimensions and calcium content of breast microcalcifications in vivo. MRI data were acquired with high spatial resolution T2-weighted (T2W) images and gradient echo images with five different echo times (TEs). The crystal areas were determined by setting the threshold relative to agarose signal. The ratio of crystal areas was calculated by the measurements from gradient echo images divided by T2W images. Then the ratios as a function of TE were fitted with the radical function. The results showed that the blooming artifacts due to magnetic susceptibility between agar and CaHA crystals were more than twice as large as the susceptibility in CaOX crystals (p < 0.05). In addition, larger bright rings were observed on gradient echo images around CaHA crystals compared to CaOX crystals. Our results suggest that MRI may provide useful information regarding breast microcalcifications by evaluating the apparent area of crystal ratios obtained between gradient echo and T2W images.  相似文献   

6.
In this paper, we address the problems of fully automatic localization and segmentation of 3D vertebral bodies from CT/MR images. We propose a learning-based, unified random forest regression and classification framework to tackle these two problems. More specifically, in the first stage, the localization of 3D vertebral bodies is solved with random forest regression where we aggregate the votes from a set of randomly sampled image patches to get a probability map of the center of a target vertebral body in a given image. The resultant probability map is then further regularized by Hidden Markov Model (HMM) to eliminate potential ambiguity caused by the neighboring vertebral bodies. The output from the first stage allows us to define a region of interest (ROI) for the segmentation step, where we use random forest classification to estimate the likelihood of a voxel in the ROI being foreground or background. The estimated likelihood is combined with the prior probability, which is learned from a set of training data, to get the posterior probability of the voxel. The segmentation of the target vertebral body is then done by a binary thresholding of the estimated probability. We evaluated the present approach on two openly available datasets: 1) 3D T2-weighted spine MR images from 23 patients and 2) 3D spine CT images from 10 patients. Taking manual segmentation as the ground truth (each MR image contains at least 7 vertebral bodies from T11 to L5 and each CT image contains 5 vertebral bodies from L1 to L5), we evaluated the present approach with leave-one-out experiments. Specifically, for the T2-weighted MR images, we achieved for localization a mean error of 1.6 mm, and for segmentation a mean Dice metric of 88.7% and a mean surface distance of 1.5 mm, respectively. For the CT images we achieved for localization a mean error of 1.9 mm, and for segmentation a mean Dice metric of 91.0% and a mean surface distance of 0.9 mm, respectively.  相似文献   

7.
8.
The purpose of the study was to determine the difference in extrahepatic bile duct (EBD) size measured by magnetic resonance (MR) compared with those measured by ultrasound (US). Changes of EBD size related to aging were analyzed too. Size of EBD was measured in 76 randomly selected healthy individuals. Three radiologists blinded to the result of other study preformed measurements by US and three different T2 weighted MR sequences. Correlation and linear regression analysis of obtained data were performed. The mean diameter of EBD measured by US was 3.17 mm and by MR was 3.14 mm on thick slab rapid acquisition with relaxation enhancement (TSE), 3.26 mm on thin section single-shot TSE (HASTE) and 3.30 mm on coronal fully rewound gradient echo (True FISP). There was no statistical difference between US and different MR sequences (p < 0.05). A trend of increase of EBD with age (0.0155 mm per year, p = 0.0954) was observed. Size of EBD highly correlated for each MR sequence with US measurement validating use of MR as a reliable method for evaluation of EBD size. This conclusion is stressed by increase of EBD size with age demonstrated by all measuring methods.  相似文献   

9.
In vivo MR imaging of magnetically labeled human embryonic stem cells   总被引:10,自引:0,他引:10  
INTRODUCTION: Human embryonic stem cells (hES) have emerged as a potentially new therapeutic approach for treatment of heart and other diseases applying the concept of regenerative medicine. A method for in vivo visualization and tracking of transplanted hES would increase our understanding of in vivo hES behavior in both experimental and clinical settings. The aim of this study was to evaluate the feasibility of magnetic labeling and visualization of hES with magnetic resonance imaging (MRI). METHODS: hES were established and expanded according to standard procedures. After expansion, the cells were cultured under feeder free conditions and magnetically labeled by addition of dextran-coated Ferrum-oxide particles (Endorem) to the medium. Accumulation of small particles of iron-oxide (SPIO) in hES was assessed by Prussian blue staining and electron microscopy. For in vitro MRI, the labeled and unlabeled hES were examined in cell solution and after transplantation into explanted mouse heart ( approximately 100,000 cells) on a Bruker Avance DMX 500 vertical magnet at 11.75 T. A multi-slice, multi spin-echo T(2)-weighted images were obtained. For in vivo imaging, the experiments were performed on male Sprague-Dawley using Bruker Biospec 2.35 T magnet. The hES were directly injected ( approximately 500,000 cells) after surgical procedure (thoracotomy) into anterior left ventricular (LV) wall. Multi-slice T(2)-weighted gradient echo images were obtained using cardiac gating. RESULTS: hES appeared to be unaffected by magnetic labeling and maintained their ability to proliferate and differentiate. No additive agent for membrane permeabilisation was needed for facilitation of intracellular SPIO accumulation. Prussian blue and electron microscopy have revealed numerous iron particles in the cytoplasm of hES. On T(2)-weighted images, the labeled cells have shown well-defined hyopintense areas at the site of injection in anterior LV wall both in vitro and in vivo. CONCLUSIONS: It is feasible to magnetically label and visualize hES both in vitro and in vivo. MR visualization of magnetically labeled hES may be a valuable tool for in vivo tracking of hES.  相似文献   

10.
PurposeTo determine the targeting accuracy of brain radiosurgery when planning procedures employing different MRI and MRI + CT combinations are adopted.Materials and methodA new phantom, the BrainTool, has been designed and realized to test image co-registration and targeting accuracy in a realistic anatomical situation. The phantom was created with a 3D printer and materials that mimic realistic brain MRI and CT contrast using a model extracted from a synthetic MRI study of a human brain. Eight markers distributed within the BrainTool provide for assessment of the accuracy of image registrations while two cavities that host an ionization chamber are used to perform targeting accuracy measurements with an iterative cross-scan method. Two procedures employing 1.5 T MRI-only or a combination of MRI (taken with 1.5 T or 3 T scanners) and CT to carry out Gamma Knife treatments were investigated. As distortions can impact targeting accuracy, MR images were preliminary evaluated to assess image deformation extent using GammaTool phantom.ResultsMR images taken with both scanners showed average and maximum distortion of 0.3 mm and 1 mm respectively. The marker distances in co-registered images resulted below 0.5 mm for both MRI scans. The targeting mismatches obtained were 0.8 mm, 1.0 mm and 1.2 mm for MRI-only and MRI + CT (1,5T and 3 T), respectively.ConclusionsProcedures using a combination of MR and CT images provide targeting accuracies comparable to those of MRI-only procedures. The BrainTool proved to be a suitable tool for carrying out co-registration and targeting accuracy of Gamma Knife brain radiosurgery treatments.  相似文献   

11.
Magnetic resonance (MR) images of the right tarsal joint of 22 normal male Han:Wistar rats were acquired using a 4.7 T magnet. An intermediate-high signal area associated with the tendon of the flexor hallus longus muscle was noticed in three rats on T2-weighted images. These areas appeared as an intermediate-high signal on lightly T2-weighted images, but appeared as an iso-signal to muscle structure on proton density weighted images. Histology preparations showed that such areas were caused by a sizable fluid collection within the synovial sheath of the tendon of the flexor hallus longus muscle, with all other joint structures appearing normal. This anatomic variant could be potentially regarded as a lesion on T2-weighted MR images, such as inflamed tissue with oedema, especially when the spatial resolution and/or signal-to-noise ratio are not optimal.  相似文献   

12.
The Brown-Roberts-Wells (BRW) computer tomography (CT) stereotactic guidance system has been modified to accommodate magnetic resonance imaging (MRI). A smaller head ring, which fits in standard MRI head coils, is constructed of a non-ferromagnetic aluminum ring that is split to prevent eddy currents and anodized to prevent MRI image distortion and resolution degradation. A new localizing device has been designed in a box configuration, which allows BRW stereotactic coordinates to be calculated from coronal and sagittal MRI images, in addition to axial images. The system was tested utilizing a phantom and T1- and T2-weighted images. Using 5-mm MRI scan slices, targets were localized accurately to a 5-mm cube in three combined planes. Optimized calibration of both low field strength (0.3 T) and high field strength (1.5 T) MRI systems is necessary to obtain thin slice (5 mm) images with acceptable image resolution. To date, 10 patients have had MRI stereotactic localization of brain lesions that were better defined by MRI than CT.  相似文献   

13.
MRI of the pelvis in comparison with CT scan   总被引:1,自引:0,他引:1  
This study gives results of magnetic resonance imaging (MRI) in the evaluation of male (23 cases) and female (29 cases) pelvis. Thirty nine patients with abnormal pelvis were compared with CT and ultrasounds. MRI and CT have proven equally sensitive to the presence of disease, with a better visualization of calcified tumours or benign lesions with CT, and a superior display of soft tissue spreads and bone metastases with MRI. The signal characteristics from various uterine, bladder and ovarian tumours show an overlap. The same phenomenon is observed between benign and malignant prostatic hypertrophy. The best sequences for pelvic study are, in our experience, IR or short TR spin-echo for T1-weighted images, and spin-echo with 1200 TR for T2 images. Calculated T1 and T2 maps may improve MRI results.  相似文献   

14.
PurposeTo measure the combined errors due to geometric inaccuracy and image co-registration on secondary images (dynamic CT angiography (dCTA), 3D DynaCT angiography (DynaCTA), and magnetic resonance images (MRI)) that are routinely used to aid in target delineation and planning for stereotactic radiosurgery (SRS).MethodsThree phantoms (one commercial and two in-house built) and two different analysis approaches (commercial and MATLAB based) were used to quantify the magnitude of geometric image distortion and co-registration errors for different imaging modalities within CyberKnife’s MultiPlan treatment planning software. For each phantom, the combined errors were reported as a mean target registration error (TRE). The mean TRE’s for different intramodality imaging parameters (e.g., mAs, kVp, and phantom set-ups) and for dCTA, DynaCTA, and MRI systems were measured.ResultsOnly X-ray based imaging can be performed with the commercial phantom, and the mean TRE ± standard deviation values were large compared to the in-house analysis using MATLAB. With the 3D printed phantom, even drastic changes in treatment planning CT imaging protocols did not greatly influence the mean TRE (<0.5 mm for a 1 mm slice thickness CT). For all imaging modalities, the largest mean TRE was found on DynaCT, followed by T2-weighted MR images (albeit all <1 mm).ConclusionsThe user may overestimate the mean TRE if the commercial phantom and MultiPlan were used solely. The 3D printed phantom design is a sensitive and suitable quality assurance tool for measuring 3D geometric inaccuracy and co-registration errors across all imaging modalities.  相似文献   

15.
AimDevelopment of MRI sequences and processing methods for the production of images appropriate for direct use in stereotactic radiosurgery (SRS) treatment planning.BackgroundMRI is useful in SRS treatment planning, especially for patients with brain lesions or anatomical targets that are poorly distinguished by CT, but its use requires further refinement. This methodology seeks to optimize MRI sequences to generate distortion-free and clinically relevant MR images for MRI-only SRS treatment planning.Materials and methodsWe used commercially available SRS MRI-guided radiotherapy phantoms and eight patients to optimize sequences for patient imaging. Workflow involved the choice of correct MRI sequence(s), optimization of the sequence parameters, evaluation of image quality (artifact free and clinically relevant), measurement of geometrical distortion, and evaluation of the accuracy of our offline correction algorithm.ResultsCT images showed a maximum deviation of 1.3 mm and minimum deviation of 0.4 mm from true fiducial position for SRS coordinate definition. Interestingly, uncorrected MR images showed maximum deviation of 1.2 mm and minimum of 0.4 mm, comparable to CT images used for SRS coordinate definition. After geometrical correction, we observed a maximum deviation of 1.1 mm and minimum deviation of only 0.3 mm.ConclusionOur optimized MRI pulse sequences and image correction technique show promising results; MR images produced under these conditions are appropriate for direct use in SRS treatment planning.  相似文献   

16.
Structural magnetic resonance imaging (MRI) has shown great utility in diagnosing soft tissue burden in osteoarthritis (OA), though MRI measures of cartilage integrity have proven more elusive. Sodium MRI can reflect the proteoglycan content of cartilage; however, it requires specialized hardware, acquisition sequences, and long imaging times. This study was designed to assess the potential of a clinically feasible sodium MRI acquisition to detect differences in the knee cartilage of subjects with OA versus healthy controls (HC), and to determine whether longitudinal changes in sodium content are observed at 3 and 6 months. 28 subjects with primary knee OA and 19 HC subjects age and gender matched were enrolled in this ethically-approved study. At baseline, 3 and 6 months subjects underwent structural MRI and a 0.4ms echo time 3D T1-weighted sodium scan as well as the knee injury and osteoarthritis outcome score (KOOS) and knee pain by visual analogue score (VAS). A standing radiograph of the knee was taken for Kellgren-Lawrence (K-L) scoring. A blinded reader outlined the cartilage on the structural images which was used to determine median T1-weighted sodium concentrations in each region of interest on the co-registered sodium scans. VAS, K-L, and KOOS all significantly separated the OA and HC groups. OA subjects had higher T1-weighted sodium concentrations, most strongly observed in the lateral tibial, lateral femoral and medial patella ROIs. There were no significant changes in cartilage volume or sodium concentration over 6 months. This study has shown that a clinically-feasible sodium MRI at a moderate 3T field strength and imaging time with fluid attenuation by T1 weighting significantly separated HCs from OA subjects.  相似文献   

17.
We compared the anatomic extent and severity of ischemic brain injury shown on diffusion-weighted magnetic resonance (MR) images, with cerebral tissue perfusion deficits demonstrated by a nonionic intravascular T2*-shortening magnetic susceptibility contrast agent used in conjunction with standard T2-weighted spin-echo and gradient-echo echo-planar images. Diffusion-weighted images displayed increased signal intensity in the vascular territory of the middle cerebral artery 25-40 min after permanent occlusion, whereas T2-weighted images without contrast were negative or equivocal for at least 2-3 h after stroke was induced. Contrast-enhanced T2-weighted and echo-planar images revealed perfusion deficits that were spatially closely related to the anatomic regions of ischemic tissue injury. These data indicate that diffusion-weighted MR images are very sensitive to early onset pathophysiologic changes induced by acute cerebral ischemia. Combined sequential diffusion-perfusion imaging enables noninvasive in vivo examination of the relationship between hypoperfusion and evolving ischemic brain injury.  相似文献   

18.
The aim of this study was to demonstrate the ability of conventional radiography to detect bone erosions of different sizes in metacarpophalangeal (MCP) joints of rheumatoid arthritis (RA) patients using magnetic resonance imaging (MRI) as the standard reference. A 0.2 T Esaote dedicated extremity MRI unit was used to obtain axial and coronal T1-weighted gradient echo images of the dominant 2nd to 5th MCP joints of 69 RA patients. MR images were obtained and evaluated for bone erosions according to the OMERACT recommendations. Conventional radiographs of the 2nd to 5th MCP joints were obtained in posterior-anterior projection and evaluated for bone erosions. The MRI and radiography readers were blinded to each other's assessments. Grade 1 MRI erosions (1% to 10% of bone volume eroded) were detected by radiography in 20%, 4%, 7% and 13% in the 2nd, 3rd, 4th and 5th MCP joint, respectively. Corresponding results for grade 2 erosions (11% to 20% of bone volume eroded) were 42%, 10%, 60% and 24%, and for grade 3 erosions (21% to 30% of bone volume eroded) 75%, 67%, 75% and 100%. All grade 4 (and above) erosions were detected on radiographs. Conventional radiography required a MRI-estimated bone erosion volume of 20% to 30% to allow a certain detection, indicating that MRI is a better method for detection and grading of minor erosive changes in RA MCP joints.  相似文献   

19.

Purpose

To evaluate whether gadoxetic acid (Gd-EOB-DTPA)-enhanced MR images of tumors taken during the hepatocyte-specific phase can aid in the differentiation between hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) in patients with atypical cirrhotic nodules detected on dynamic CT images.

Materials and Methods

Seventy-one patients with 112 nodules showing atypical dynamic enhancement on CT images underwent gadoxetic acid-enhanced MR imaging (MRI) studies. Using a reference standard, we determined that 33 of the nodules were DNs and that 79 were true HCCs. Tumor size, signal intensity on precontrast T1-weighted images (T1WI) and T2WI, and the pattern of dynamic enhancement on MR images taken in the hepatocyte-phase were determined.

Results

There were significant differences in tumor size, hyperintensity on T2WI, hypointensity on T1WI, typical HCC enhancement pattern on dynamic MR images, or hypointensity on hepatocyte-phase images between DNs and HCC. The sensitivity and specificity were 60.8% and 87.9% for T2WI, 38.0% and 87.9% for T1WI, 17.7% and 100% for dynamic MR imaging, 83.5% and 84.9% for hepatocyte-phase imaging, and 60.8% and 87.9% for tumor size (threshold of 1.7 cm).

Conclusion

Gd-EOB-DTPA-enhanced hepatocyte-phase imaging is recommended for patients at high risk of HCC who present with atypical lesions on dynamic CT images.  相似文献   

20.

Purpose

To minimize feature loss in T1- and T2-weighted MRI by merging multiple MR images acquired at different TR and TE to generate an image with increased dynamic range.

Materials and Methods

High Dynamic Range (HDR) processing techniques from the field of photography were applied to a series of acquired MR images. Specifically, a method to parameterize the algorithm for MRI data was developed and tested. T1- and T2-weighted images of a number of contrast agent phantoms and a live mouse were acquired with varying TR and TE parameters. The images were computationally merged to produce HDR-MR images. All acquisitions were performed on a 7.05 T Bruker PharmaScan with a multi-echo spin echo pulse sequence.

Results

HDR-MRI delineated bright and dark features that were either saturated or indistinguishable from background in standard T1- and T2-weighted MRI. The increased dynamic range preserved intensity gradation over a larger range of T1 and T2 in phantoms and revealed more anatomical features in vivo.

Conclusions

We have developed and tested a method to apply HDR processing to MR images. The increased dynamic range of HDR-MR images as compared to standard T1- and T2-weighted images minimizes feature loss caused by magnetization recovery or low SNR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号