共查询到20条相似文献,搜索用时 15 毫秒
1.
Sang-Heon Lee Sun D. Yoo Kyu-Hyun Lee 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,724(2):182
This report describes a rapid, simple and sensitive isocratic high-performance liquid chromatography with diode array UV detection for micro-sample analysis of paclitaxel in mouse plasma. The analysis utilized a Capcell-pak octadecyl analytical column and a mobile phase consisting of acetonitrile–0.1% phosphoric acid in deionized water (55:45, v/v). Paclitaxel and n-hexyl p-hydroxybenzoic acid (internal standard) were extracted from plasma by one-step extraction with tert.-butyl methyl ether. Peak purity was determined over a UV wavelength range of 200 to 400 nm. Paclitaxel and the internal standard were eluted at 3.4 min and 5.4 min, respectively, at a mobile phase flow-rate of 1.3 ml/min. No interfering peaks were observed and the total run time was 10 min. The standard curve was linear (r=0.9999) over the concentration range of 0.010–500 μg/ml. The extraction recovery was >90% for both paclitaxel and n-hexyl p-hydroxybenzoic acid. The intra- and inter-day assay variabilities of paclitaxel ranged from 0.4 to 2.2% and 0.6 to 7.8%, respectively. The LOD and LOQ were 5 and 10 ng/ml, respectively, for paclitaxel using a plasma sample volume of 100 μl. This highly sensitive and simple assay method was successfully applied to a pharmacokinetic study after i.v. administration of paclitaxel 20 mg/kg to mice. 相似文献
2.
3.
J. Macek P. Pt
ek J. Klíma 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,755(1-2)
A rapid high-performance liquid chromatographic method for the quantitation of citalopram in human plasma is presented. The sample preparation involved liquid–liquid extraction of citalopram with hexane–isoamyl alcohol (98:2 v/v) and back-extraction of the drug to 0.02 M hydrochloric acid. Liquid chromatography was performed on a cyano column (45×4.6 mm, 5 μm particles), the mobile phase consisted of an acetonitrile–phosphate buffer, pH 6.0 (50:50, v/v). The run time was 2.6 min. The fluorimetric detector was set at an excitation wavelength of 236 nm and an emission wavelength of 306 nm. Verapamil was used as the internal standard. The limit of quantitation was 0.96 ng/ml using 1 ml of plasma. Within- and between-day precision expressed by relative standard deviation was less than 7% and inaccuracy did not exceed 6%. The assay was applied to the analysis of samples from a pharmacokinetic study. 相似文献
4.
5.
Pastore A Lo Russo A Piemonte F Mannucci L Federici G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,776(2):251-254
A simple, accurate and sensitive high-performance liquid chromatographic method with UV detection was carried out to measure plasma concentrations of mycophenolic acid. Following a simplified acid hydrolysis of the sample, the separation was carried out in 4 min using a Zorbax Eclipse C(8) reversed-phase column with a flow-rate of 1.5 ml/min, and monitoring the absorbance at 250 nm. Throughput was up to 100 samples in 24 h. Within the investigated concentration ranges of mycophenolic acid (0-100 mg/l), good linearity (r>0.99) was obtained. The method is sensitive (the limit of detection was about 20 microg/l) and precise (for 0.49 mg/l added to plasma, within-run C.V. was 2% and between-run was 4.2%; for 2.88 mg/l, within-run C.V. was 0.35% and between-run C.V. was 0.69%; for 24.38 mg/l, within-run C.V. was 0.77% and between-run C.V. was 3.1%). Analytical recoveries were 96% for 0.5 mg/l mycophenolic acid added to plasma, 100% for 12 mg/l and 102.5% for 24 mg/l. 相似文献
6.
7.
A. J. Lagerwerf
L. E. H. Vanlinthout
T. B. Vree
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1991,570(2):390-395A high-performance liquid chromatographic method with fluorometric detection has been developed for the determination of succinylcholine in human plasma. Succinylcholine shows fluorescence at 282 nm with an excitation at 257 nm. The assay is sensitive, reproducible and linear for concentrations ranging from 100 ng/ml to 100 μg/ml of succinylcholine. In a pilot study the plasma concentration—time curve showed a triphasic elimination, with half-lives of 0.4, 1.2 and 8 min, respectively. In a clinical setting, drugs commonly administered during anaesthesia did not interfere with the assay. This method provides a simple and time-saving alternative to existing methods. 相似文献
8.
Macek J Klíma J Ptácek P 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,832(1):169-172
A high-performance liquid chromatographic (HPLC) method for the determination of valsartan in human plasma is reported. The assay is based on protein precipitation with methanol and reversed-phase chromatography with fluorimetric detection. The preparation of a batch of 24 samples takes 20 min. The liquid chromatography was performed on an octadecylsilica column (50 mm x 4 mm, 5 microm particles), the mobile phase consisted of acetonitrile -15 mM dihydrogenpotassium phosphate, pH 2.0 (45:55, v/v). The run time was 2.8 min. The fluorimetric detector was operated at 234/374 nm (excitation/emission wavelength). The limit of quantitation was 98 ng/ml using 0.2 ml of plasma. Within-day and between-day precision expressed by relative standard deviation was less than 5% and inaccuracy did not exceed 8%. The assay was applied to the analysis of samples from a pharmacokinetic study. 相似文献
9.
10.
Abolhassan Ahmadiani Hossein Amini 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,751(2):291-296
A simple high-performance liquid chromatographic procedure was developed for the determination of ranitidine in human plasma. The method entailed direct injection of the plasma samples after deproteination using perchloric acid. The chromatographic separation was accomplished with an isocratic elution using mobile phase consisting of 21 mM disodium hydrogen phosphate–triethylamine-acetonitrile (1000:60:150, v/v), pH 3.5. Analyses were run at a flow-rate of 1.3 ml/min using a μbondapak C18 column and ultraviolet detection at a wavelength of 320 nm. The method was specific and sensitive, with a quantification limit of approximately 20 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 96%, while the within- and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The linearity was assessed in the range of 20–1000 ng/ml plasma, with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailability studies. 相似文献
11.
Denise A. Egan Richard O'Kennedy 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,582(1-2)
A rapid and sensitive high-performance liquid chromatographic method was developed for the analysis of coumarin, 7-hydroxycoumarin and its glucuronide conjugate in urine and plasma. This method was used to monitor the urinary excretion of these compounds following a single oral dose of coumarin (100 mg). This new method gives excellent chromatographic separation and includes an internal standard. The method was validated and shown to be both accurate and precise in the range 0.5–100 μg/ml. 相似文献
12.
13.
Rapid determination of loratadine in small volume plasma samples by high-performance liquid chromatography with fluorescence detection 总被引:2,自引:0,他引:2
Amini H Ahmadiani A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,809(2):227-230
A simple and rapid high-performance liquid chromatographic method with fluorescence detection was developed for the determination of loratadine in small volume plasma samples. Liquid-liquid extraction of loratadine and diazepam (as internal standard) from plasma samples was performed with n-butyl alcohol/n-hexane (2:98, v/v) in alkaline condition followed by back-extraction into diluted perchloric acid. Chromatography was carried out using a C8 column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-20 mM sodium dihydrogen phosphate-triethylamine (43:57:0.02, v/v), pH 2.4. Analyses were run at a flow-rate of 1.0 ml/min at room temperature. The method was specific and sensitive with a quantitation limit of 0.62 ng/ml and a detection limit of 0.2 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery of loratadine from plasma was 84%, while the intra-and inter-day coefficient of variation and percent error values of the assay method were all less than 9.7%. Linearity was assessed in the range of 0.62-20 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method has been used to analyze several hundred human plasma samples for bioavailability studies. 相似文献
14.
Rapid determination of tamsulosin in human plasma by high-performance liquid chromatography using extraction with butyl acetate 总被引:2,自引:0,他引:2
Macek J Klíma J Ptácek P 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,809(2):307-311
A high-performance liquid chromatographic method with fluorescence detection for the determination of tamsulosin in human plasma is reported. The sample preparation involved liquid-liquid extraction of tamsulosin from alkalised plasma with butyl acetate and back-extraction of the drug to the phosphate buffer (pH 2). Butyl acetate is preferable to more commonly used ethyl acetate because of its much lower solubility in water. Liquid chromatography was performed on an octadecylsilica column (55 mm x 4 mm, 3 microm particles), the mobile phase consisted of acetonitrile-30 mM dihydrogenpotassium phosphate (25:75 v/v). The run time was 3.5 min. The fluorimetric detector was operated at 228/326 nm (excitation/emission wavelength). An analogue of tamsulosin, (R)-5-[2-[(3-(2-ethoxyphenoxy)propyl)amino]-2-methylethyl]-2-methoxybenzensulfonamide was used as the internal standard. The limit of quantitation was 0.4 ng/ml using 1 ml of plasma. Within-day and between-day precision expressed by relative standard deviation was less than 10% and inaccuracy did not exceed 5%. The assay was applied to the analysis of samples from several pharmacokinetic studies. 相似文献
15.
16.
George Jia-Long Lee James E. Evans Howard Tieckelmann 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1978,146(3):439-448
The separation and quantitative analysis of enzymatic degradation products of isomeric chondroitin sulfates by high-performance liquid chromatography (HPLC) are described. The substituted unsaturated disaccharides which result from digestion of chondroitin sulfates with chondroitinase are quickly separated on polar adsorbents such as silica gel. The UV absorption properties of these unsaturated disaccharides permit UV measurement with detection limits of approximately 100 ng. Their separation by HPLC facilitates the use of enzymatic methods for the determination of chondroitin sulfates A, B and C.
The potential of this method in clinical application is demonstrated by quantitative assays of glycosaminoglycans from a normal urine and urine from a patient with Hunter syndrome. The results are consistent with amount of isomeric chondroitin sulfates found in comparable urines by others. 相似文献
17.
18.
Hisakazu Ohtani Hajime Kotaki Yasufumi Sawada Tatsuji Iga 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1996,683(2):281-284
A high-performance liquid chromatographic (HPLC) method for the quantitative determination of epinastine, a non-sedating histamine H1 receptor antagonist, in rat plasma, was developed. A 100-μl volume of plasma sample was spiked with a solution of internal standard (diphenidol) and extracted with dichloromethane under alkaline conditions. The extract was applied onto the HPLC system and detected by ultraviolet absorption at a wavelength of 220 nm. The linearity of the calibration curve was preserved over the concentration range of 20--1000 ng/ml. Both intra-assay variation and relative error were less than 5% for the plasma sample containing 50 ng/ml or 1000 ng/ml of epinastine hydrochloride. The analytical method presented here should be useful for the investigation of the pharmacokinetic properties of epinastine, which is of clinical significance. 相似文献
19.
20.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,694(2):197
A simple and reproducible method for the determination of zolpidem in human plasma is presented. This method involves protein precipitation with methanol (2 ml of methanol are added to 0.5 ml of plasma) and reversed-phase chromatography with fluorescence detection (excitation wavelength 244 nm, emission wavelength 388 nm). The mobile phase consists of methanol–30 mM dihydrogen potassium phosphate–triethylamine (30:69:1). pH of the aqueous part of the mobile phase is 6.8. No internal standard is required. Limit of quantitation is 1.5 ng/ml and the calibration curve is linear up to 400 ng/ml. Within-day and between-day precision expressed by relative standard deviation is less than 5% and inaccuracy also does not exceed 9%. The assay is useful for pharmacokinetic studies. 相似文献