A reversed-phase, high-performance liquid chromatographic method using UV detection is described for the assay of the major metabolite of phentolamine in plasma and urine before or after enzymatic hydrolysis. Plasma is deproteinized with methanol. The sensitivity limit is 200 ng/ml using 150-μl samples. Urine is either diluted with water or purified after enzymatic hydrolysis. Concentrations down to 2–3 μg/ml could be quantified with acceptable precision. This method was applied to plasma and urine samples from subjects given phentolamine.  相似文献   

2.
Quantitative methods for determination of amoxicillin in body fluids are described. They comprise separation by reversed-phase chromatography (LiChrosorb RP-8, 5 μm) of the aqueous supernatants obtained from plasma or urine after purification steps involving protein precipitation followed by extraction in the case of plasma, or a double extraction procedure in the case of urine, post-column derivatization with air segmentation, and finally measurement of the UV absorbance at 310 nm. The derivatization involves formation of the mercuric mercaptide of penicillenic acid and is specific for compounds with an intact penicillanic acid ring system.Detection limits achieved on injecting 200 μl of plasma and 20 μl of urine are about 25 ng/ml and 200 ng/ml, respectively, but it is possible to improve the sensitivity further by injecting larger volumes. Precisions (srel) obtained for determination of 0.10 and 0.45 μg/ml in plasma were 3.72 and 1.40%, respectively.Some problems regarding column stability originating from the injection of biological samples are discussed.  相似文献   

3.
(E)-5-(2-Bromovinyl)-2′-deoxyuridine is an antiviral drug used for treatment of infections with Herpes simplex virus type 1 as well as Varicella zoster virus. Two fast methods for the determination of the drug and its metabolite in plasma and urine by capillary electrophoresis have been developed. The plasma method can be used for measurement of total as well as unbound drug and metabolite. Plasma and urine samples are prepared for measuring by liquid/liquid extraction resulting in a limit of quantification of 40 ng/ml for total and 10 ng/ml for free BVdU in plasma and 170 ng/ml in urine. Inter- as well as intra-day precision were found to be better than 10% and both methods have been used for drug monitoring of patients.  相似文献   

4.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

5.
Aplidine (dehydrodidemnin B) is a new marine-derived depsipeptide with a powerful cytotoxic activity, which is under early clinical investigation in Europe and in the US. In order to investigate the pharmacokinetic properties of this novel drug, an HPLC–tandem mass spectrometry method was developed for the determination of aplidine in biological samples. Didemnin B, a hydroxy analogue, was used as internal standard. After protein precipitation with acetonitrile and extraction with chloroform, aplidine was chromatographed with a RP octadecylsilica column using a water–acetonitrile linear gradient in the presence of formic acid at the flow-rate of 500 μl/min. The method was linear over a 5–100 ng/ml range (LOD=0.5 ng/ml) in plasma and over a 1.25–125 ng/ml range (LOD=0.2 ng/ml) in urine with precision and accuracy below 14.0%. The intra- and inter-day precision and accuracy were below 12.5%. The extraction procedure recoveries for aplidine and didemnin B were 69% and 68%, respectively in plasma and 91% and 87%, respectively in urine. Differences in linearity, LOQ, LOD and recoveries between plasma and urine samples seem to be matrix-dependent. The applicability of the method was tested by measuring aplidine in rat plasma and urine after intravenous treatment.  相似文献   

6.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

7.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method has been developed for the determination of trenbolone in bovine urine and serum. The aim was a control of the misuse of trenbolone in food-producing animals. The procedure involved, in both cases, a preliminary solid-phase clean-up followed by a liquid-liquid extraction for urine samples after a preliminary enzymatic hydrolysis. The extracts have been directly analysed by reversed-phase LC-MS-MS in selected reaction monitoring (SRM), acquiring two diagnostic product ions from the chosen precursor [M+H](+). The procedures were validated across the concentration range of 1-1500 ng/ml. The linearity, the inter- and intra-day accuracy and precision have been determined. The procedure was specific and the accuracy values were better than 20% at the limit of quantitation of spiked samples. The limit of quantification (LOQ) and the limit of detection (LOD) were, respectively, 1 ng/ml and 350 pg/ml for urine and serum. According to the draft, SANCO/1805/2000, we determined the decision limit CCalpha and the detection capability CCbeta. The recovery values for urine ranged from 87 to 128%, and for plasma the recovery was 70+/-4%. The procedure proved to be simple and suitable for routine and confirmatory purposes such as those developed for residue studies.  相似文献   

8.
Two liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) methods are described, one for the quantitative determination of risperidone and the enantiomers of its active metabolite 9-hydroxyrisperidone (paliperidone) in human plasma and the other for the determination of the enantiomers of 9-hydroxyrisperidone in human urine. The plasma method is based on solid-phase extraction of 200 microl of sample on a mixed-mode sorbent, followed by separation on a cellulose-based LC column with a 13.5-min mobile phase gradient of hexane, isopropanol and ethanol. After post-column addition of 10 mM ammonium acetate in ethanol/water, detection takes place by ion-spray tandem mass spectrometry in the positive ion mode. Method validation results show that the method is sufficiently selective towards the enantiomers of 7-hydroxyrisperidone and capable of quantifying the analytes with good precision and accuracy in the concentration range of 0.2-100 ng/ml. An accelerated (run time of 4.3 min) and equally valid method for the enantiomers of 9-hydroxyrisperidone alone in plasma is obtained by increasing the mobile phase flow-rate from 1.0 to 2.0 ml/min and slightly adapting the gradient conditions. The urine method is based on the same solid-phase extraction and chromatographic approach as the accelerated plasma method. Using 100 microl of sample, (+)- and (-)-9-hydroxyrisperidone can be quantified in the concentration range 1-2000 ng/ml. The accelerated method for plasma and the method for urine can be used only when paliperidone is administered instead of risperidone, as there is insufficient separation of the 9-hydroxy enantiomers from the 7-hydroxy enantiomers, the latter ones being present only after risperidone administration.  相似文献   

9.
Two methods for the extraction of morphine from cerebrospinal fluid or plasma with quantitation by high-performance liquid chromatography with electrochemical detection were compared for accuracy, precision and ease of preparation. One procedure was a standard extraction procedure and the other utilized a commercially available liquid—liquid extraction column. Both methods produced linear calibration curves over the concentration range of 1–200 ng/ml with coefficients of correlation of 0.999. Since the electrochemical detector is capable of detecting 20 pg of morphine, biological samples as small as 0.1 to 0.4 ml can be quantified with an average relative precision of 4.1 ± 3.9% over the concentration range 1–200 ng/ml. The potential clinical importance of the assay is demonstrated using a time course distribution study of morphine in the cerebrospinal fluid and plasma of a Rhesus monkey.  相似文献   

10.
A method for the determination of L-756 423, a novel HIV protease inhibitor, in human plasma and urine is described. Plasma and urine samples were extracted using 3M Empore extraction disk cartridges in the C18 and MPC (mixed-phase cation-exchange) formats, respectively. The extract was analyzed using HPLC with fluorescence detection (ex 248 nm, em 300 nm), and included a column switching procedure to reduce run-time. The assay was linear in the concentration range 5 to 1000 ng/ml when 1-ml aliquots of plasma and urine were extracted. Recoveries of L-756 423 were greater than 84% over the calibration curve range using the described sample preparation procedures. Intra-day precision and accuracy for this assay was less than 9% RSD and within 7%, respectively. Inter-day variabilities for the plasma (n=17) and urine (n=10) were less than 5% and 3% for low (15 ng/ml) and high (750 ng/ml) quality control samples. Bovine serum albumin (0.5%) was used as an additive to urine to prevent precipitation of L-756 423 during the storage of clinical samples. The assay was used in support of human clinical trials.  相似文献   

11.
Here we report a sensitive liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method capable of quantifying nicotine down to 1 ng/ml and cotinine to 10 ng/ml from 1.0 ml of human plasma. The method was validated over linear ranges of 1.0–50.0 ng/ml for nicotine and 10.0–500.0 ng/ml for cotinine, using deuterated internal standards. Compounds were simply extracted from alkalinized human heparinized plasma with methylene chloride, reconstituted into a solution of acetonitrile, methanol and 10 mM ammonium acetate (53:32:15, v/v) after the organic phase was dried down, and analyzed on the LC-MS-MS, which is a PE Sciex API III system equipped with a Keystone BDS Hypersil C18 column and atmospheric pressure chemical ionization (APCI) interface. The between-run precision and accuracy of the calibration standards were ≤6.42% relative standard deviation (R.S.D.) and ≤11.8%n relative error (R.E.) for both nicotine and cotinine. The between-run and within-run precision and accuracy of quality controls. (2.5, 15.0, 37.5 ng/ml for nicotine and 25.0, 150.0, 375.0 ng/ml for cotinine), were ≤6.34% R.S.D. and ≤7.62% R.E. for both analytes. Sample stabilities in chromatography, in processing and in biological matrix were also investigated. This method has been applied to pharmacokinetic analysis of nicotine and cotinine in human plasma.  相似文献   

12.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

13.
An analytical method for the determination of letrozole (CGS 20 267) in plasma and of letrozole and its metabolite, CGP 44 645, in urine is described. Automated liquid-solid extraction of compounds from plasma and urine was performed on disposable 100-mg C8 columns using the ASPEC system. The separation was achieved on an ODS Hypersil C18 column using acetonitrile-phosphate buffer, pH 7, as the mobile phase at a flow-rate of 1.5 ml/min. A fluorescence detector was used for the quantitation. The excitation and emission wavelengths were 230 and 295 nm, respectively. The limits of quantitation (LOQ) of letrozole in plasma and in urine were 1.40 nmol/l (0.4 ng/ml) and 2.80 nmol/l, respectively. The respective mean recoveries and coefficient of variation (C.V.) were 96.5% (9.8%) in plasma and 104% (7.7%) in urine. The LOQ of CGP 44 645 in urine was 8.54 nmol/l (2 ng/ml). The mean recovery was 108% (6.3%). The compounds were well separated from co-extracted endogenous components and no interferences were observed at the retention times of compounds. The sensitivity of this method for letrozole in plasma should be sufficient for kinetic studies in humans with single doses of 0.5 mg and possibly less.  相似文献   

14.
A high-performance capillary electrophoresis (HPCE) assay was used to determine the concentration of a potent cytotoxic agent, dolastatin-10, in human plasma. Following extraction from plasma, using a solid-phase C18 cartridge, capillary zone electrophoresis was used to separate, detect and quantitate dolastatin-10 using the structurally related compound dolastatin-15 as the internal standard. Migration times for both dolastatins are less than 20 min. The recovery of the drug was approximately 90% and was quantified over the assay range of 39 to 5000 ng/ml with good precision and accuracy. The method is linear up to 5000 ng/ml with a lower limit of detection of 25 ng/ml. Data resulting from the use of the assay for the in vitro metabolism of the drug are presented. This is the first report of a validated HPCE assay for determining dolastatin-10 levels in human plasma.  相似文献   

15.
A rapid and sensitive high-performance liquid chromatographic (HPLC) assay for the determination of alpha-naphthylisothiocyanate (1-NITC) and two metabolites alpha-naphthylamine (1-NA) and alpha-naphthylisocyanate (1-NIC) in rat plasma and urine has been developed. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Partisphere C(18) 5-microm column, a mobile phase of acetonitrile-water (ACN-H(2)O 70:30, v/v), and detection by ultraviolet (UV) absorption at 305 nm. The lower limits of quantitation (LLQ) in rat plasma, urine, and ACN were 10, 30, and 10 ng/ml for 1-NITC; 30, 100, and 30 ng/ml for 1-NA; and 30 ng/ml in ACN for 1-NIC. At low (10 ng/ml), medium (500 ng/ml), and high (5000 ng/ml) concentrations of quality control samples (QCs), the range of within-day and between-day accuracies were 95-106 and 97-103% for 1-NITC in plasma, respectively. Stability studies showed that 1-NITC was stable at all tested temperatures in ACN, and at -20 and -80 degrees C in plasma, urine, and ACN precipitated plasma and urine, but degraded at room temperature and 4 degrees C. 1-NA was stable in all of the tested matrices at all temperatures. 1-NIC was unstable in plasma, urine, and ACN precipitated plasma and urine, but stable in ACN. The degradation product of 1-NITC and 1-NIC in universal buffer was confirmed to be 1-NA. 1-NITC and 1-NA were detected and quantified in rat plasma and urine, following the administration of a 25 mg/kg i.v. dose of 1-NITC to a female Sprague-Dawley rat.  相似文献   

16.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

17.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

18.
This article describes the development and validation of a simple solid phase extraction (SPE) and HPLC method for the extraction and the specific determination of prednisolone and hydrocortisone (cortisol) in both plasma and urine using one washing step with Oasis hydrophilic lipophilic balanced (HLB) cartridges (1 ml/30 mg, 30 microm). Recoveries of prednisolone and cortisol from plasma and urine exceeded 82%. The limit of quantification (LOQ) in plasma and urine was 9.9 and 6.7 ng/ml for cortisol, respectively, and 11.6 and 8.0 ng/ml for prednisolone, respectively. The intraday and interday precision (measured by CV%) for both prednisolone and cortisol in both plasma and urine was always less than 7%. The accuracy (measured by relative error %) for both prednisolone and cortisol in both plasma and urine was always less than 8%. The advantages of the developed method are the use of a one step washing SPE utilising HLB cartridges which do not suffer the drying out problems of conventional SPE cartridges and the time saving when compared with solvent extraction (SE), in addition to the simultaneous determination of prednisolone and cortisol in both plasma and urine.  相似文献   

19.
A validated method for determination of total amount of ketotifen (unchanged and conjugated) in human plasma has been presented. An enzyme hydrolysis of conjugated ketotifen was conducted with combination of β-glucuronidase and arylsulfatase. After the enzyme hydrolysis a solid-phase extraction was applied as a cleaning step. The quantitative determination by gas chromatography with mass-spectrometry detection (GC–MS) was performed. Pizotifen has been used as an internal standard. A reliable hydrolysis as well as a satisfactory accuracy, improved precision in the linear region from 0.500 to 10.0 ng/ml plasma, limit of detection of 0.010 ng/ml and prolonged capillary column life have been achieved.  相似文献   

20.
Sensitive assays for the determination of cyclobenzaprine (I) in human plasma and urine were developed utilizing high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) and ultraviolet (UV) absorbance detections. These two analytical techniques were evaluated for reliability and sensitivity, and applied to support pharmacokinetic studies. Both methods employed a liquid-liquid extraction of the compound from basified biological sample. The organic extract was evaporated to dryness ,the residue was reconstituted in the mobile phase and injected onto the HPLC system. The HPLC assay with MS-MS detection was performed on a PE Sciex API III tandem mass spectrometer using the heated nebulizer interface. Multiple reaction monitoring using the parent → daughter ion combinations of m/z 276 → 215 and 296 → 208 was used to quantitate I and internal standard (II), respectively. The HPLC-MS-MS and HPLC-UV assays were validated in human plasma in the concentration range 0.1–50 ng/ml and 0.5–50 ng/ml, respectively. In urine, both methods were validatedin the concentration range 10–1000 ng/ml. The precision of the assays, as expressed as coefficients of variation (C.V.) was less than 10% over the entire concentration range, with adequate assay specificity and accuracy. In addition to better sensitivity, the HPLC-MS-MS assay was more efficient and allowed analysis of more biological fluid samples in a single working day than the HPLC-UV method.  相似文献   