首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hydroxocobalamin (OHCbl) is a powerful antidote for cyanide poisoning, via the formation of non-toxic cyanocobalamin (CNCbl). Plasmatic cobalamins were measured at 361 nm, after enrichment and purification on a short C18 precolumn (1% acetic acid; 1 ml min−1; 2 min), by back-flush elution on a C18 ODS-2 column [0.1 M sodium dihydrogenphosphate-methanol (63:27, v/v) (pH 4.0); 0.80 ml min−1]. The precision was 3.21 and 3.54% for 10 μM OHCbl and CNCbl, respectively. The method was used to study the pharmacokinetics of OHCbl and the formed CNCbl in severely poisoned patients.  相似文献   

2.
The overall objective of this research was to develop a sensitive, specific, and stability-indicating HPLC assay for the determination of the [Nle4-DPhe7]α-melanocyte-stimulating hormone analog known as Melanotan-1 (MT-1) in biological matrices, i.e., cell culture transport media and human plasma. Separation was accomplished isocratically within 8.0 min using a C8 reversed-phase column. The mobile phase consisted of 0.1 M phosphate buffer-acetonitrile (80:20, v/v) with 18 μl/l triethylamine at pH 2.50. The flow-rate was 1 ml/min with detection at 214 nm. Standard curves (n = 5) were linear over the concentration range 100–1000 ng/ml. The precision, accuracy, intra- and inter-day variations were good with C.V.s typically within 8.7% for concentrations greater than 100 ng/ml. This method was applied to a study of the transport of MT-1 in the Caco-2 cell monolayer model.  相似文献   

3.
A high-performance liquid chromatographic method for the determination of the anthelmintic nitroxynil has been developed. The drug was extracted from cattle muscle tissue with 1% triethylamine in acetonitrile. The extract was evaporated to dryness and taken up in 0.1 M ammonium acetate—acetonitrile (50:50, v/v). The extract was then injected onto a polymeric anion-exchange precolumn. After clean-up with 0.1 M ammonium acetate—acetonitrile (50:50, v/v) for 5 min, the precolumn was eluted with 1% aqueous trifluoroacetic acid—acetonitrile (50:50, v/v) onto a PLRP-S polymer column and chromatographed with a mobile phase of 0.01 M phosphate pH 7—acetonitrile (80:20, v/v). Detection was by ultraviolet at 273 nm. Average recoveries at four levels from 0.005 to 1.000 mg kg−1 were > 88%. The limit of determination was 0.005 mg kg−1.  相似文献   

4.
An isocratic reversed-phase HPLC method was developed to determine cefepime levels in plasma and vitreous fluid. Cefepime and the internal standard cefadroxil were separated on a Shandon Hypersil BDS C18 column by using a mobile phase of 25 mM sodium dihydrogen phosphate monohydrate (pH 3) and methanol (87:13, v/v). Ultraviolet detection was carried out at 270 nm. The retention times were 4.80 min for cefepime and 7.70 min for cefadroxil. This fast procedure which involves an efficient protein precipitation step (addition of HClO4), allows a quantification limit of 2.52 μg ml−1 and a detection limit of 0.83 μg ml−1. Recoveries and absolute recoveries of cefepime from plasma were 96.13–99.44% and 94–102.5% respectively. The intra-day and inter-day reproducibilities were less than 2% for cefepime at 10, 30, 50 μg ml−1 (n=10).The method was proved to be suitable for determining cefepime levels in human plasma and was modified to measure vitreous fluid samples.  相似文献   

5.
A sensitive HPLC assay has been developed to determine the concentration of 17-(allylamino)-17-demethoxygeldanamycin (AAG) in human plasma over the concentration range of 12.5 to 2500 nM (7.33 to 1465 ng/mL). After the addition of 1000 nM geldanamycin as the internal standard, 1 mL samples of human plasma were subjected to solid-phase extraction, via Bond-Elut C18 cartridges, followed by analysis using an isocratic reversed-phase HPLC assay with UV detection. A Phenomenex Kingsorb, 3 micron, C18, 150×4.60 mm column and a Phenomenex Security Guard pre-column, C18 (ODS, Octadecyl), were used to achieve separation. AAG and GM were monitored at 334 and 308 nm, respectively, on a Hewlett-Packard 1050 Diode-Array Detector. The mobile phase, run at a flow-rate of 1 mL/min, was composed of 50% (v/v) 25 mM sodium phosphate (pH 3.00) with 10 mM triethylamine and 50% acetonitrile. HPLC effectively resolved AAG with retention times of 14.60 0.54 min and the internal standard geldanamycin at 10.72±0.38 min (n=15). This assay was able to measure plasma concentrations of AAG, the lower limit of quantitation being 12.5 nM, at a starting dose of 10 mg/m2 infused intravenously over 1 h in a Phase I clinical trial in adult patients with solid tumors.  相似文献   

6.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating cocaine and its three metabolites in rat serum microsamples (50 μl). The separation used a 2.1-mm I.D. reversed-phase Brownlee C18 column with an isocratic mobile phase consisting of methanol–acetonitrile–25.8 mM sodium acetate buffer, pH 2.2, containing 1.29·10−4M tetrabutylammonium phosphate (12.5:10:77.5, v/v/v). The detection limit was 2.5 ng/ml for all the compounds using an ultraviolet detector operated at 235 nm. The method was used to study the pharmacokinetics of cocaine after an intravenous (i.v.) bolus dose (4 mg/kg).  相似文献   

7.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

8.
This study describes a sensitive HPLC–electrochemical detection method for the analysis of ceftazidime, a third-generation cephalosporin, in human plasma. The extraction procedure involved protein precipitation with 30% trichloroacetic acid. The separation was achieved on a reversed-phase column (250×4.6 mm I.D., 5 μm) packed with C18 Kromasil with isocratic elution and a mobile phase consisting of acetonitrile–25 mM KH2PO4–Na2HPO4 buffer, pH 7.4 (10:90, v/v). The proposed analytical method is selective, reproducible and reliable. The assay has a precision of 0.2–15.1% (C.V.) in the range of 5–200 μg ml−1. (corresponding to 0.5 to 20 ng of ceftazidime injected onto the column), and is optimised for assaying 50 μl of plasma. The extraction recovery from plasma was approximately 100%. The method was highly specific for ceftazidime and there was no interference from either commonly administered drugs or endogenous compounds. This assay was used to measure ceftazidime in elderly patients for therapeutic drug monitoring.  相似文献   

9.
An HPLC method for determining a flavonoid, naringin, and its metabolite, naringenin, in human plasma is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using genistin (for naringin) or daidzein (for naringenin) as an internal standard and solid-phase extraction using a Sep-Pak t C18 cartridge. For the determination, HPLC was carried out using an Inertsil ODS-2 column (250x4.6 m I.D., 5 μm particle size). The mobile phases were acetonitrile-0.1 M ammonium acetate solution (20:80, v/v; pH 7.1) for naringin and acetonitrile-0.1 M ammonium acetate solution-acetic acid (30:69:1, v/v; pH 4.9) for naringenin. The flow-rate was 1 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 280 nm for naringin and at 292 nm for naringenin. The detection limits on-column were about 0.2 ng for the two flavonoids.  相似文献   

10.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating zolpidem in rat serum microsamples (50 μl). The separation used a 2.1 mm I.D. reversed-phase OD-5-100 C18 column, 5 μm particle size with an isocratic mobile phase consisting of methanol–acetonitrile–26 mM sodium acetate buffer (adjusted to pH 2.0 with 40% phosphoric acid) containing 0.26 mM tetrabutylammonium phosphate (13:10:77, v/v/v). The detection limit was 3 ng/ml for zolpidem using an ultraviolet detector operated at 240 nm. The recovery was greater than 87% with analysis performed in 12 min. The method is simple, rapid, and applicable to pharmacokinetic studies of zolpidem after administering two intravenous bolus doses (1 and 4 mg/kg) in rats.  相似文献   

11.
A new method is presented for the HPLC determination of plasma 2′-deoxyuridine (dUrd). Briefly, 1 ml of human plasma is deproteinised with perchloric acid followed by purification by solid-phase extraction using a non-polar high-capacity polymeric sorbent. The dUrd is separated on a C18 reversed-phase column using a mobile-phase of 0.05% v/v trifluoroacetic acid in water, with a retention time of 8.5 min at a flow-rate of 1.25 ml min−1. Quantitation is by UV detection at 261 nm using a photodiode array detector. The limit of quantitation is 6 nM with a linear response over the measured range 6–400 nM. Both intra- and inter-day RSD and bias are typically less than 13%. Chromatograms and pharmacodynamic data from a Phase 1 Clinical Trial of a new antifolate drug, ZD9331 are included to illustrate the utility of the method. They show the increase in circulating dUrd as a result of drug inhibition of the target enzyme thymidylate synthase. The method has the significant advantages of ease and simplicity over earlier methods and may be applied to the analysis of other nucleoside species.  相似文献   

12.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

13.
For the determination of cisapride from serum samples, an automated microbore high-performance liquid chromatographic method with column switching has been developed. After serum samples (100 μl) were directly injected onto a Capcell Pak MF Ph-1 pre-column (10×4 mm I.D.), the deproteinization and concentration were carried out by acetonitrile–phosphate buffer (20 mM, pH 7.0) (2:8, v/v) at valve position A. At 2.6 min, the valve was switched to position B and the concentrated analytes were transferred from MF Ph-1 pre-column to a C18 intermediate column (35×2 mm I.D.) using washing solvent. By valve switching to position A at 4.3 min, the analytes were separated on a Capcell Pak C18 UG 120 column (250×1.5 mm I.D.) with acetonitrile–phosphate buffer (20 mM, pH 7.0) (5:5, v/v) at a flow-rate of 0.1 ml/min. Total analysis time per sample was 18 min. The linearity of response was good (r=0.999) over the concentration range of 5–200 ng/ml. The within-day and day-to-day precision (CV) and inaccuracy were less than 3.7% and 3.8%, respectively. The mean recovery was 96.5±2.4% with the detection limit of 2 ng/ml.  相似文献   

14.
15.
A stereoselective and sensitive achiral/chiral method for the determination of terfenadine acid metabolite in human plasma was developed. The metabolite was separated and quantitated using an achiral chromatographic procedure with a cyano column. The mobile phase was 1 mM sodium acetate buffer (pH 4.0) and acetonitrile (25:75% v/v) at a flow rate of 2 ml/min, at ambient temperature. The stereospecific resolution was accomplished using a chiral-AGP column and a mobile phase consisting of sodium acetate (0.01 M): methanol (98.7:1.3% v/v), and 20 mM di-n-butylamine at a flow rate of 1.2 ml/min. The column temperature was maintained at 32°C. The eluent was monitored at 230 nm (excitation) and 300 nm (emission) with a cut-off filter at 270 nm. This assay was used for a pharmacokinetic study in five subjects after administration of a single dose of 60 mg of terfenadine. The t½ values of the two enantiomers were similar, but the AUC values of the (+)-enantiomer were 2.05–2.35 times higher than those of (?)-enantiomer. © 1994 Wiley-Liss, Inc.  相似文献   

16.
A thermodynamic study of the inclusion process between 2-chlorobenzophenone (2ClBP) and cyclomaltoheptaose (β-cyclodextrin, β-CD) was performed using UV–vis spectroscopy, reversed-phase liquid chromatography (RP-HPLC), and molecular modeling (PM6). Spectrophotometric measurements in aqueous solutions were performed at different temperatures. The stoichiometry of the complex is 1:1 and its apparent formation constant (Kc) is 3846 M−1 at 30 °C. Temperature dependence of Kc values revealed that both enthalpy (ΔH° = −10.58 kJ/mol) and entropy changes (ΔS° = 33.76 J/K mol) are favorable for the inclusion process in an aqueous medium. Encapsulation was also investigated using RP-HPLC (C18 column) with different mobile-phase compositions, to which β-CD was added. The apparent formation constants in MeOH–H2O (KF) were dependent of the proportion of the mobile phase employed (50:50, 55:45, 60:40 and 65:35, v/v). The KF values were 419 M−1 (50% MeOH) and 166 M−1 (65% MeOH) at 30 °C. The thermodynamic parameters of the complex in an aqueous MeOH medium indicated that this process is largely driven by enthalpy change (ΔH° = −27.25 kJ/mol and ΔS° = −45.12 J/K mol). The results of the study carried out with the PM6 semiempirical method showed that the energetically most favorable structure for the formation of the complex is the ‘head up’ orientation.  相似文献   

17.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

18.
A rapid reversed-phase high-performance liquid chromatographic method with a 30-mm long column is described for assaying amphotericin B in serum. After deproteinization of serum samples with methanol, the supernatant was injected onto a reversed-phase C18 column, using 2.5 mM Na2EDTA-acetonitrile (70:30, v/v) as the mobile phase. Amphotericin B was eluted at 1.5 min. Calibration plot of the peak area against concentration was linear from 0.05 to 25 μg/ml (C.V. of 3%). Within-day and day-to-day imprecision (C.V.) ranged between 1.33% and 3.61%. The application was evaluated in 55 serum samples from patients treated with amphotericin B.  相似文献   

19.
A method is described for the analysis of amino acids, monoamines and metabolites by high-performance liquid chromatography with electrochemical detection (HPLC–ED) from individual brain areas. The chromatographic separations were achieved using microbore columns. For amino acids we used a 100×1 mm I.D. C8, 5 μm column. A binary mobile phases was used: mobile phase A consisted of 0.1 M sodium acetate buffer (pH 6.8)–methanol–dimethylacetamide (69:24:7, v/v) and mobile phase B consisted of sodium acetate buffer (pH 6.8)–methanol–dimethylacetamide (15:45:40, v/v). The flow-rate was maintained at 150 μl/min. For monoamines and metabolites we used a 150×1 mm I.D. C18 5 μm reversed-phase column. The mobile phase consisted of 25 mM monobasic sodium phosphate, 50 mM sodium citrate, 27 μM disodium EDTA, 10 mM diethylamine, 2.2 mM octane sulfonic acid and 10 mM sodium chloride with 3% methanol and 2.2% dimethylacetamide. The potential was +700 mV versus Ag/AgCl reference electrode for both the amino acids and the biogenic amines and metabolites. Ten rat brain regions, including various cortical areas, the cerebellum, hippocampus, substantia nigra, red nucleus and locus coeruleus were microdissected or micropunched from frozen 300-μm tissue slices. Tissue samples were homogenized in 50 or 100 μl of 0.05 M perchloric acid. The precise handling and processing of the tissue samples and tissue homogenates are described in detail, since care must be exercised in processing such small volumes while preventing sample degradation. An aliquot of the sample was derivatized to form the tert.-butylthiol derivatives of the amino acids and γ-aminobutyric acid. A second aliquot of the same sample was used for monamine and metabolite analyses. The results indicate that the procedure is ideal for processing and analyzing small tissue samples.  相似文献   

20.
A sensitive and very specific method, using liquid chromatography–electrospray mass spectrometry (LC–ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform–2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)–acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 μm (150×1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)–acetonitrile (70:30, v/v) as mobile phase, delivered at 50 μl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r≥0.992) and 200 ng/ml for the active metabolites (r≥0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号