首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The analysis of melarsoprol in whole blood, plasma, urine and cerebrospinal fluid is described. Extraction was made with a mixture of chloroform and acetonitrile followed by back-extraction into phosphoric acid. A reversed-phase liquid chromatography system with ultraviolet detection was used. The relative standard deviation was 1% at concentrations around 10 μmol/l and 3–6% at the lower limit of determination (9 nmol/l in plasma, 93 nmol/l in whole blood, 45 nmol/l in urine and 10 nmol/l in cerebrospinal fluid). Melarsoprol is not a stable compound and samples to be stored for longer periods of time should be kept at −70°C. Plasma samples can be stored at −20°C for upt to 2 months. Chromatography showed that melarsoprol contains two components. Using nuclear magnetic resonance spectroscopy the two components were shown to be diastereomers which slowly equilibrate by inversion of the configuration at the As atom.  相似文献   

2.
Analytical methods for the determination of melagatran (H 319/68) in biological samples by liquid chromatography (LC)-positive electrospray ionization mass spectrometry using multiple reaction monitoring are described. Melagatran in plasma was isolated by solid-phase extraction on octylsilica, either in separate extraction tubes or in 96-well plates. Absolute recovery of melagatran from plasma was >92%. Melagatran and the internal standard, H 319/68 D2 13C2, were separated from other sample components by LC utilizing a C18 stationary phase and a mobile phase comprising 35% acetonitrile and 0.08% formic acid in 0.0013 mol/l ammonium acetate solution. After dilution, urine was injected directly onto the LC column and subjected to gradient LC. The relative standard deviation was 1-5% for concentrations above the limit of quantification, which was estimated for plasma at 10 or 25 nmol/l for sample volumes of 500 or 200 microl, respectively, and 100 nmol/l for urine.  相似文献   

3.
A quantitative method for the determination of proteins in complex biological matrices has been developed based on the selectivity of antibodies for sample purification followed by proteolytic digestion and quantitative mass spectrometry. An immunosorbent of polyclonal anti-bovine serum albumin (BSA) antibodies immobilized on CNBR agarose is used in the on-line mode for selective sample pretreatment. Next, the purified sample is trypsin digested to obtain protein specific peptide markers. Subsequent analysis of the peptide mixture using a desalination procedure and a separation step coupled, on-line to an ion-trap mass spectrometer, reveals that this method enables selective determination of proteins in biological matrices like diluted human plasma. This approach enhances substantially the selectivity compared to common quantitative analysis executed with immunoassays and colorimetry, fluorimetry or luminescence detection. Hyphenation of the immunoaffinity chromatography with on-line digestion and chromatography-mass spectrometry is performed and a completely on-line quantification of the model protein BSA in bovine and human urine was established. A detection limit of 170 nmol/l and a quantification limit of 280 nmol/l is obtained using 50 microl of either standard or spiked biological matrix. The model system allows fully automated absolute quantitative mass spectrometric analysis of intact proteins in biological matrices without time-consuming labeling procedures.  相似文献   

4.
A sensitive, selective and accurate high-performance liquid chromatographic–tandem mass spectrometric assay was developed and validated for the determination of lidocaine and its metabolites 2,6-dimethylaniline (2,6-xylidine), monoethylglycinexylidide and glycinexylidide in human plasma and urine. A simple sample preparation technique was used for plasma samples. The plasma samples were ultrafiltered after acidification with phosphoric acid and the ultrafiltrate was directly injected into the LC system. For urine samples, solid-phase extraction discs (C18) were used as sample preparation. The limit of quantification (LOQ) was improved by at least 10 times compared to the methods described in the literature. The LOQ was in the range 1.6–5 nmol/l for the studied compounds in plasma samples.  相似文献   

5.
The protein-linked glycomes and, thereby, the range of individual monosaccharides of invertebrates differ from those of mammals due to a number of special modifications; therefore, it is necessary to adapt methods for monosaccharide analysis in order to cover these. We optimized the labeling procedure for anthranilic acid (AA) and 1-phenyl-3-methyl-5-pyrazolone (PMP) and the subsequent separation of the labeled monosaccharides on high-performance liquid chromatography (HPLC), with the result that we were able to identify 26 different monosaccharides. The detection limit for anthranilic acid derivatives obtained was 65 fmol, and a reliable quantification of samples was possible up to 200 nmol under the tested conditions. PMP derivatives showed a significantly higher detection limit but allow quantification of larger sample amounts. Applying these methods on snails, their impressive set of monosaccharide constituents, including methylated sugars, was shown.  相似文献   

6.
A method for the determination of a synthetic polymeric compound with antitumor activity (copovithane) and methylamine in blood plasma and urine is described. Copovithane is prepared by radical polymerisation of a diurethane with N-vinylpyrrolidone.The method is based on high-performance liquid chromatography of the methylamine hydrochloride which arises during the hydrochloric acid hydrolysis of the parent substance. The methylamine hydrochloride is converted to the trinitrobenzenesulphonyl derivative for the purpose of chromatographic detection.The limit of determination for copovithane in blood plasma is 1.2 mg/l and in urine 1.5 mg/day. The determination limit for methylamine in blood plasma is 0.2 mg/1 and in urine 0.3 mg/day. The imprecision is dependent on the sample, and amounts to ± 6.8% for blood plasma and ± 6.4% for urine.  相似文献   

7.
Roscovitine, a purine analogue that selectively inhibits cyclin-dependent kinases, has been considered as a potential anti-tumor drug. The determination of roscovitine in plasma and urine was performed using microextraction in packed syringe as on-line sample preparation method with liquid chromatography and tandem mass spectrometry. The sampling sorbent utilized was polystyrene polymer. 2H3-lidocaine was used as internal standard. The limit of detection for roscovitine was as low as 0.5 ng/mL and the lower limit of quantification was 1.0 ng/mL. The accuracy and precision values of quality control samples were between +/-15% and < or =11%, respectively. The calibration curve was obtained within the concentration range 0.5-2000 ng/mL in both plasma and urine. The regression correlation coefficients for plasma and urine samples were > or =0.999 for all runs. The present method is miniaturized and fully automated and can be used for pharmacokinetic and pharmacodynamic studies.  相似文献   

8.
Concentrations of inorganic anions, both as individual species and biotransformation products, in physiological fluids are of strong concern in clinical studies. To date, analytical methodologies have either required different analytical procedures to determine these analytes in plasma and urine, or extensive sample preparation, or unconventional and often expensive detection schemes, or both. A simple and sensitive capillary electrophoresis (CE) method with direct UV detection was developed for the simultaneous determination of iodide, bromide and nitrate in human plasma and urine, with a special focus on reliable quantification of the trace serum iodide. With the latter objective, the method incorporates a transient isotachophoresis (tITP) procedure enabling an efficient on-line preconcentration of iodide (limit of detection, 1.4 microg l(-1)) as well as other moderately mobile analytes that fall into the tITP range. The analyses of both types of biofluids were performed using an acidic electrolyte system composed of 0.25 mol l(-1) sodium chloride and 7.5 mmol l(-1) cetyltrimethylammonium chloride at pH 2.2 and 0.5 mol l(-1) 2-(N-morpholino)ethanesulfonate (pH 6.0) as terminating electrolyte. Relative standard deviations (R.S.D.) below 3.0% and 9.2% were obtained for within-day and between-day precision, respectively. Resolution and quantification of oxalic acid was also feasible under optimized tITP-CE conditions. Sample preparation required only ultrafiltration (serum) and dilution (urine). A number of plasma and urine samples were evaluated with this assay and the iodide, bromide and nitrate concentrations were in the expected clinical concentration ranges.  相似文献   

9.
The feasibility of using plasma, blood and haemoglobin adducts for monitoring occupational exposure to the suspected human carcinogen 4,4′-methylenebis(2-chloroaniline) (MOCA) was investigated. A method utilising capillary gas chromatography-negative-ion chemical-ionisation mass spectrometry (GC-MS) for the determination of pentafluoropropionyl (PFP) derivatives of MOCA, released by alkaline hydrolysis from protein adducts and conjugates, was both sensitive and selective. When selected ion monitoring was used, sub-femtomole amounts of PFP-MOCA could be measured. The detection limit for haemoglobin adducts of MOCA was below 10 fmol/g Hb, well below the levels found for occupationally exposed individuals. Capillary GC with electron-capture detection also had the required sensitivity for the determination of MOCA in blood and urine of five individuals who were exposed to MOCA during the manufacture of polyurethane elastomers were determined by the GC-MS method. The MOCA concentrations for the various blood fractions and urine were within the following ranges: haemoglobin adducts, 0.73–43.3 pmol MOCA/g Hb; plasma alkaline hydrolysate, 0.05–22.0 nmol/l; whole blood, 0.13–17.4nmol/l; urine, 4.5–2390 nmol/l. Because the products of MOCA in the blood reflect metabolic activation of MOCA and integrate exposure over a period of weeks, the use of blood samples for monitoring exposure to MOCA offers advantages over the currently used urinary MOCA measurements.  相似文献   

10.
A high-performance liquid chromatographic technique for ethyl alcohol determination in body fluids is proposed. Ethyl alcohol is quantitatively converted into acetaldehyde-phenylhydrazone by oxidation in the presence of alcohol dehydrogenase, nicotinamide–adenine dinucleotide and phenylhydrazine. The derivative is suitable for reversed-phase liquid chromatography and ultraviolet detection at 276 nm. The limits of linearity, detection and quantification as well as accuracy and reproducibility were investigated in water, serum and whole blood. Analytical responses were linear within the 0.008 to 5 g/l range, and the limit of quantification was 0.02 g/l both in aqueous standard and in biological matrix assays. Mean analytical recovery of ethyl alcohol in blood serum averaged 98.2±4.2%, imprecision (CV%) at 0.80 g/l was 2.2%, and the limit of quantification was 0.02 g/l. Serum concentrations of persons that avoided alcoholic beverages for a week were less than the limit of quantification. Ethyl alcohol concentrations in serum and whole blood compared well with those obtained by headspace gas chromatography. This simple and reliable procedure, which was also used for a urine assay, could be suitable for validation of the screening procedures used to monitor ethanol abuse.  相似文献   

11.
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 μl of plasma) and 25 ng/ml (50 μl of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.  相似文献   

12.
Two novel metabolites of benproperine (BPP), 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-3-piperidinol (3-OH-BPP) and 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-4-piperidinol (4-OH-BPP), were confirmed by comparison of retention times and mass spectra with those of synthetic standards using liquid chromatography-tandem mass spectrometry. Selective and sensitive procedures were developed for the simultaneous determination of BPP, 3-OH-BPP and 4-OH-BPP in human plasma and urine. The analytes were extracted from plasma sample and enzymatically hydrolyzed urine samples by liquid-liquid extraction, separated through a Diamonsil C(18) column (150 mm x 4.6 mm i.d.) and determined by tandem mass spectrometry with an electrospray ionization interface in selected reaction monitoring mode. Dextromethorphan was used as internal standard. The mobile phase consisted of acetonitrile-water-formic acid (34:66:1, v/v/v), and flow-rate was 0.5 ml min(-1). This method has a lower limit of quantification (LLOQ) of 60, 4.0 and 4.0 nmol l(-1)for BPP, 3-OH-BPP and 4-OH-BPP in plasma, 4.9, 4.7 and 2.4 nmol l(-1) in urine, respectively. The intra- and inter-run precision were measured to be below 9.2%, and the accuracy was within +/-4.3% for the analytes. The method was successfully used to determine BPP, 3-OH-BPP and 4-OH-BPP in plasma and urine for pharmacokinetic investigation. The results indicated residue of 3-OH-BPP in the body at least 192 h after an oral dose of BPP.  相似文献   

13.
A new method for the analysis of 1-hydroxy-2-imidazol-1-yl-phosphonoethyl phosphoric acid (zoledronic acid) in urine and blood samples has been developed. It consists of a derivatisation of the bisphosphonate with trimethylsilyl diazomethane under multiple methylester formation. The formed derivative can, in contrast to the non-derivatised analyte, easily be separated by reversed phase liquid chromatography due to its reduced polarity. Detection is performed by electrospray tandem mass spectrometry. For calibration purposes, a deuterated internal standard has been synthesised in a three-step synthesis starting with d(4)-imidazole. For human urine, the limit of detection (LOD) is 1.2x10(-7) mol/L, limit of quantification (LOQ) is 3.75×10(-7) mol/L in the MRM mode. For human blood plasma, a LOD of 1×10(-7) mol/L and a LOQ of 2.5×10(-7) mol/L were determined. The linear dynamic range comprised 3.5 decades starting at the limit of quantification. The method was successfully applied for the analysis of spiked urine and blood plasma samples as well as samples from two osteoporosis patients.  相似文献   

14.
A sensitive and specific high-performance liquid chromatographic assay with electrospray ionization mass spectrometry detection (LC-ESI-MS) has been developed and validated for the identification and quantification of the novel anticholinergic drug phencynonate in rat blood and urine. The sample pretreatment involves basification and iterative liquid-liquid extraction with ethyl ether-dichloromethane (2:1, v/v) solution, followed by LC separation and positive electrospray ionization mass spectrometry detection. The chromatography was on BetaBasic-18 column (150 mm x 2.1mm i.d., 3 microm). The mobile phase was composed of methanol-water (85:15, v/v), containing 0.5 per thousand formic acid, which was pumped at a flow-rate of 0.2 ml/min. Thiencynonate was selected as the internal standard (IS). Simultaneous MS detection of phencynonate and IS was performed at m/z 358.4 (phencynonate), m/z 364 (thiencynonate), and the selected reaction ion monitoring (SRM) of the two compounds was at 156. Phencynonate eluted at approximately 5.25 min, thiencynonate eluted at approximately 5.10 min and no endogenous materials interfered with their measurement. Linearity was obtained over the concentration range of 1-100 ng/ml in rat blood and 1-500 ng/ml in rat urine. The lower limit of quantification (LLOQ) was reproducible at 1 ng/ml in both of rat blood and urine. The precision measured was obtained from 2.92 to 9.76% in rat blood and 4.17 to 9.76% in rat urine. Extraction recoveries were in the range of 69.57-79.49% in blood and 56.85-64.86% in urine. This method was successfully applied to the identification and quantification of phencynonate in pharmacokinetic studies.  相似文献   

15.
The rat excretes around 2 nmol epidermal growth factor (EGF) in the urine per 24 h. The urinary EGF might be derived from plasma and/or might be synthesized in the kidneys. We have used the rat to study the renal uptake and excretion of homologous EGF from plasma. I.v. injected 125I-EGF was removed from the circulation within a few minutes. 5 min after the injection, the kidneys contained 12% of the 125I-EGF. The kidneys seemed to degrade most of the 125I-EGF which they accumulated from blood, as only 4% of the injected label was excreted as intact 125I-EGF in the urine. The amount of endogenous EGF in plasma was under the detection limit of our enzyme-linked immunosorbent assay (0.03 nmol/l) and it remained so after bilateral nephrectomy. Even if plasma EGF was 0.03 nmol/l excretion of EGF from plasma could account for less than 5% of the urinary EGF. This study shows that the kidneys are able to accumulate EGF from plasma and excrete a part of it as intact EGF in the urine. However, excretion of immunoreactive EGF from plasma can only account for a minor part of the urinary EGF.  相似文献   

16.
A method has been developed for the rapid quantitative analysis of chloroquine and its metabolite desethyl-chloroquine in plasma, blood and urine using high-performance liquid chromatography. An ethylene dichloride extract of the alkalinized biological samples was extracted with dilute acid and chromatographed on a reversed-phase column. Phosphate buffer in acetonitrile was used as the mobile phase with perchlorate as the counter-ion. Ultraviolet absorption at 254 or 340 nm or fluorescence detection was used. The fluorescence spectra and the fluorescence quantum yield of the substances were determined.Chloroquine and desethyl-chloroquine concentrations in the range of 10 nmol/l (UV-detection) and of 0.5 nmol/l (fluorescence detection) could be accurately measured with a relative standard deviation of 12%. The method should be adequate for therapeutic and pharmacokinetic studies.  相似文献   

17.
A liquid chromatographic method is described for the determination of total 5-methyltetrahydrofolate (5-MTHF) in whole-blood samples. The method was applied to a survey of whole-blood total 5-MTHF levels of women at child-bearing age. To determine whole-blood total 5-MTHF content, a whole-blood sample was frozen and thawed to break red blood cells and the 5-MTHF polyglutamates were released and hydrolyzed into 5-MTHF monoglutamate by endogenous polyglutamates hydrolase in the plasma. In brief, an aliquot of 0.1 ml whole-blood sample was mixed with 0.3 ml 57 mmol/l ascorbic acid and incubated at 37 degrees C for 60 min, then diluted with 0.6 ml buffer solution (0.2 mol/l potassium phosphate dibasic and 30 mmol/l mercaptoethanol, pH 8.5). After the sample was heated at 100 degrees C for 10 min and centrifuged, the supernatant was analyzed by reversed-phase liquid chromatography with fluorescence detection. The recoveries from spiked samples were from 95 to 105% with within-day and day-to-day relative standard deviations less than 6.5%. The detection limit was estimated to be 30 nmol/l based on three times the noise level (peak to peak). Application of the method to a survey of whole-blood total 5-MTHF levels of women at child-bearing age showed that the method was reliable and suitable for the determination of blood total 5-MTHF.  相似文献   

18.
There are few studies in which direct measurement of vitamin B6 status in both plasma and red cells has been assessed. The aims of the present study were to evaluate the use of a simple, robust HPLC method of direct pyridoxal 5'-phosphate (PLP) measurement in plasma and red cells and to assess its use in establishing reference ranges in a healthy population. A reverse phase HPLC method with pre-column derivatisation using semicarbazide for the simultaneous measurement of PLP, its degradation product, 4-pyridoxic acid (PA) and pyridoxal (PL) in plasma and red cells was developed. Pre-column derivatisation, reverse phase chromatography and detection procedures were optimised. The recovery, precision, linearity and sensitivity of the assay for plasma and red cell PLP, PA and PL was established. The recovery of PLP was greater than 95% for both plasma and red cell samples. The Intra and Inter batch imprecision for PLP was less than 6% and 7%, respectively. The method for PLP was linear up to at least 1000 nmol/l and the detection limit was 2.1 nmol/l (limit of quantification; 5.8 nmol/l). Accuracy of PLP measurements in plasma were acceptable, showing a mean bias of 4.5% from the mean value of laboratories (N=34) participating in an external quality assurance scheme. Geometric mean (95% reference intervals) for plasma and red cell PLP in the healthy subjects (N=126) were 56 (21-138) nmol/l and 410 (250-680) pmol/g Hb, respectively. There was a strong positive correlation (r(2)=0.81) between plasma and red cell PLP levels in the reference population. The HPLC method described was found to be suitable for the routine measurement of PLP in both plasma and red cells.  相似文献   

19.
The excretion of mercury, copper and zinc in urine, and mercury in whole blood andplasma, was determined in 40 chloralkali workers exposed to mercury vapour and 40age-matched referents. The Hg concentrations in whole blood, plasma and urine werehigher in the exposed group (35 nmol l, 30 nmol l,and 11.5 nmol mmol creatinine, respectively) in comparison with thereference group (15 nmol l, 6.3 nmol l, and 1.8nmol mmol creatinine, respectively). The urinary copper excretionwas similar in the two groups, while U-Zn excretion was significantly higher (P = 0.04)in the exposed group, median 0.83 mmol mmol creatinine versus 0.76mnmol mmol creatinine in the reference group. In a subgroup of exposedworkers with current U-Hg above 11.5 nmol lmmolcreatinine (20 mg g creatinine) the medianU-Zn was 1.1 mmol mmol creatinine. In both groups smokers had highU-Zn levels than non smokers. When both U-Hg and smoking were taken into account in alinear regression model, there was a significant association between U-Hg and U-Zn inthe combined group of exposed and referents (P = 0.002). This study indicates thatmercury exposure in humans, as in animals, causes increased urinary excretion of zinc.The mechanisms may be induced synthesis of metallothionein in the kidneys, displacementof Zn from preexisting metallothionein by Hg, or a decreased reabsorption of zinc in thekidneys owing to a slight tubular dysfunction.  相似文献   

20.
Plasma alkylresorcinols are increasingly analyzed in cohort studies to improve estimates of whole grain intake and their relationship with disease incidence. Current methods require large volumes of solvent (>10 ml/sample) and have relatively low daily sample throughput. We tested five different supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography–mass spectrometry analysis. Sample preparation with HybridSPE supported extraction was most effective for alkylresorcinol extraction, with recoveries of 77–82% from 100 μl of plasma. The use of 96-well plates allowed extraction of 160 samples per day. Using a 5-cm NH2 column and heptane reduced run times to 3 min. The new method had a limit of detection and limit of quantification equivalent to 1.1–1.8 nmol/L and 3.5–6.1 nmol/L plasma, respectively, for the different alkylresorcinol homologues. Accuracy was 93–105%, and intra- and inter-batch precision values were 4–18% across different plasma concentrations. This method makes it possible to quantify plasma alkylresorcinols in 100 μl of plasma at a rate of at least 160 samples per day without the need for large volumes of organic solvents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号