首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Boron neutron capture therapy (BNCT) depends on the selective delivery of a sufficient number of (10)B atoms to tumor cells to sustain a lethal (10)B(n,alpha)(7)Li reaction. Expression of FR frequently is amplified among human tumors. The goal of the present study was to investigate folate receptor (FR)-targeted liposomes as potential carriers for a series of boron-containing agents. Two highly ionized boron compounds, Na(2)[B(12)H(11)SH] and Na(3) (B(20)H(17)NH(3)), were incorporated into liposomes by passive loading with encapsulation efficiencies of 6% and 15%, respectively. In addition, five weakly basic boronated polyamines were investigated. Two were the spermidine derivatives: N(5)-(4-carboranylbutyl)spermidine.3HCl (SPD-5), N(5)-[4-(2-aminoethyl-o-carboranyl)butyl]spermidine.4HCl (ASPD-5). Three were the spermine derivatives: N(5)-(4-carboranylbutyl)spermine.4HCl (SPM-5), N(5)-[4-(2-aminoethyl-o-carboranyl)butyl]spermine.5HCl (ASPM-5), and N(5),N(10)-bis(4-carboranylbutyl)spermine.4 HCl (SPM-5,10). These were incorporated into liposomes by a pH-gradient-driven remote-loading method with varying loading efficiencies, which were influenced by the specific trapping agent and the structure of the boron compound. Greater loading efficiencies were obtained with lower molecular weight boron derivatives, using ammonium sulfate as the trapping agent, compared to those obtained with sodium citrate. The in vitro uptake of folate-derivatized, boronated liposomes was investigated using human KB squamous epithelial cancer cells, which have amplified FR expression. Higher cellular boron uptake (up to 1584 microg per 10(9) cells) was observed with FR-targeted liposomes than with nontargeted control liposomes (up to 154 microg per 10(9) cells), irrespective of the chemical form of the boron and the method used for liposomal preparation. KB cell binding of the FR-targeted liposomes was saturable and could be blocked by 1 mM free folic acid. Our findings suggest that further evaluation of FR-targeted liposomes is warranted to assess their potential as boron carriers for neutron capture therapy.  相似文献   

2.
Invasive nonfunctional pituitary adenomas (NFPAs) are difficult to completely resect and often develop tumor recurrence after initial surgery. Currently, no medications are clinically effective in the control of NFPA. Although radiation therapy and radiosurgery are useful to prevent tumor regrowth, they are frequently withheld because of severe complications. Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively and maximally damages tumor cells without harming the surrounding normal tissue. Folate receptor (FR)-targeted boron-10 containing carbon nanoparticles is a novel boron delivery agent that can be selectively taken up by FR-expressing cells via FR-mediated endocytosis. In this study, FR-targeted boron-10 containing carbon nanoparticles were selectively taken up by NFPAs cells expressing FR but not other types of non-FR expressing pituitary adenomas. After incubation with boron-10 containing carbon nanoparticles and following irradiation with thermal neutrons, the cell viability of NFPAs was significantly decreased, while apoptotic cells were simultaneously increased. However, cells administered the same dose of FR-targeted boron-10 containing carbon nanoparticles without neutron irradiation or received the same neutron irradiation alone did not show significant decrease in cell viability or increase in apoptotic cells. The expression of Bcl-2 was down-regulated and the expression of Bax was up-regulated in NFPAs after treatment with FR-mediated BNCT. In conclusion, FR-targeted boron-10 containing carbon nanoparticles may be an ideal delivery system of boron to NFPAs cells for BNCT. Furthermore, our study also provides a novel insight into therapeutic strategies for invasive NFPA refractory to conventional therapy, while exploring these new applications of BNCT for tumors, especially benign tumors.  相似文献   

3.
Preclinical studies for boron neutron capture therapy (BNCT) using epithermal neutrons are ongoing at several laboratories. The absorbed dose in tumor cells is a function of the thermal neutron flux at depth, the microscopic boron concentration, and the size of the cell. Dosimetry is therefore complicated by the admixture of thermal, epithermal, and fast neutrons, plus gamma rays, and the array of secondary high-linear-energy-transfer particles produced within the patient from neutron interactions. Microdosimetry can be a viable technique for determining absorbed dose and radiation quality. A 2.5-cm-diameter tissue-equivalent gas proportional counter has been built with 50 parts per million (ppm) 10B incorporated into the walls and counting gas to simulate the boron uptake anticipated in tumors. Measurements of lineal energy (y) spectra for BNCT in simulated volumes of 1-10 microns diameter show a dose enhancement factor of 4.3 for 30 ppm boron, and a "y" of 250 keV/microns for the boron capture process. Chamber design plus details of experimental and calculated linear energy spectra will be presented.  相似文献   

4.
5.
G J Storr 《Radiation research》1992,131(3):235-242
The discrete-ordinates transport computer code DORT has been used to develop a two-dimensional cylindrical phantom model for use as a tool to assess beam design and dose distributions for boron neutron capture therapy. The model uses an S8 approximation for angular fluxes and a P3 Legendre approximation for scattering cross sections. A one-dimensional discrete-ordinates model utilizing the computer code ANISN was used to validate the energy-group structure used in the two-dimensional calculations. In the two-dimensional model the effects of varying basic parameters such as aperture width, neutron source energy, and tissue composition have been studied. Identical results were obtained when comparing narrow beam calculations to fine-mesh higher-order Sn treatments (up to S32), and with P5 cross sections. It is shown that, when the correct assessment volume is used, narrow beams will give little or no advantage for therapy even with an optimum-energy ideal neutron beam.  相似文献   

6.
The concept of conjugating boron cluster compounds to monoclonal antibodies has been examined by several groups of research workers in boron neutron capture therapy (BNCT). The procedures reported to date for boronation of monoclonal antibodies resulted in either an inadequate level of boron incorporation, the precipitation of the conjugates, or a loss of immunological activity. The present report describes the conjugation of dicesium-mercapto-undecahydrododecaborate (Cs2B12H11SH) to 225.28S monoclonal antibody directed against high molecular weight melanoma-associated antigens (HMW-MAA), using poly-L-ornithine as a "bridge" to increase the carrying capacity of the antibody and to minimize change in the conformational structure of antibody. The method produces a boron content of 1,300 to 1,700 B atoms per molecule 225.28S while retaining the immunoreactivity. Characterization in terms of the homogeneity of the conjugation of the boron-monoclonal antibody conjugates has been studied by gel electrophoresis and ion-exchange HPLC.  相似文献   

7.
Concise synthetic methods for synthesizing 3-carboranyl thymidine analogues (3CTAs) modified with cyclic and acyclic alcohols have been developed. The synthesis of these potential boron neutron capture therapy (BNCT) agents and their preliminary biological evaluation is described.  相似文献   

8.
Neutron capture therapy (NCT) research encompasses a wide range of preclinical and clinical studies needed to develop this promising but complex cancer treatment. Many specialized facilities and capabilities including thermal and epithermal neutron irradiation facilities, boron analysis, specialized mixed-field dosimetry, animal care facilities and protocols, cell culture laboratories, and, for human clinical studies, licenses and review board approvals are required for NCT research. Such infrastructure is essential, but much of it is not readily available within the community. This is especially true for neutron irradiation facilities, which often require significant development and capital investment too expensive to duplicate at each site performing NCT research. To meet this need, the NCT group at the Massachusetts Institute of Technology (MIT) has established a User Center for NCT researchers that is already being accessed successfully by various groups. This paper describes the facilities, capabilities and other resources available at MIT and how the NCT research community can access them.  相似文献   

9.
The survival curves and the RBE for the dose components generated in boron neutron capture therapy (BNCT) were determined separately in neutron beams at Japan Research Reactor No. 4. The surviving fractions of V79 Chinese hamster cells with or without 10B were obtained using an epithermal neutron beam (ENB), a mixed thermal-epithermal neutron beam (TNB-1), and a thermal (TNB-2) neutron beam; these beams were used or are planned for use in BNCT clinical trials. The cell killing effect of the neutron beam in the presence or absence of 10B was highly dependent on the neutron beam used and depended on the epithermal and fast-neutron content of the beam. The RBEs of the boron capture reaction for ENB, TNB-1 and TNB-2 were 4.07 +/- 0.22, 2.98 +/- 0.16 and 1.42 +/- 0.07, respectively. The RBEs of the high-LET dose components based on the hydrogen recoils and the nitrogen capture reaction were 2.50 +/- 0.32, 2.34 +/- 0.30 and 2.17 +/- 0.28 for ENB, TNB-1 and TNB-2, respectively. The RBEs of the neutron and photon components were 1.22 +/- 0.16, 1.23 +/- 0.16, and 1.21 +/- 0.16 for ENB, TNB-1 and TNB-2, respectively. The approach to the experimental determination of RBEs outlined in this paper allows the RBE-weighted dose calculation for each dose component of the neutron beams and contributes to an accurate inter-beam comparison of the neutron beams at the different facilities employed in ongoing and planned BNCT clinical trials.  相似文献   

10.
Takagaki, M., Ono, K., Masunaga, S-I., Kinashi, Y., Oda, Y., Miyatake, S-I., Hashimoto, N., Powell, W., Sood, A. and Spielvogel, B. F. Boronated Dipeptide Borotrimethylglycylphenylalanine as a Potential Boron Carrier in Boron Neutron Capture Therapy for Malignant Brain Tumors. Radiat. Res. 156, 118-122 (2001).A boronated dipeptide, borotrimethylglycylphenylalanine (BGPA), was synthesized as a possible boron carrier for boron neutron capture therapy (BNCT) for malignant brain tumors. In vitro, at equal concentrations of (10)B in the extracellular medium, BGPA had the same effect in BNCT as p-boronophenylalanine (BPA). Boron analysis was carried out using prompt gamma-ray spectrometry and track-etch autoradiography. The tumor:blood and tumor:normal brain (10)B concentration ratios were 8.9 +/- 2.1 and 3.0 +/- 1.2, respectively, in rats bearing intracranial C6 gliosarcomas using alpha-particle track autoradiography. The IC(50), i.e. the dose capable of inhibiting the growth of C6 gliosarcoma cells by 50% after 3 days of incubation, was 5.9 x 10(-3) M BGPA, which is similar to that of 6.4 x 10(-3) M for BPA. The amide bond of BGPA is free from enzymatic attack, since it is protected from hydrolysis by the presence of a boron atom at the alpha-carbon position of glycine. These results suggest promise for the use of this agent for BNCT of malignant brain tumors. Further preclinical studies of BGPA are warranted, since BGPA has advantages over both BPA and BSH.  相似文献   

11.
p-boronophenylalanine (BPA) conjugated Gd-DTPA complex (3) was synthesized from the active methyne compound 6, the allylic carbonate 7, and BPA by the palladium-catalyzed allylation reaction followed by the DCC coupling reaction. The in vivo biodistribution of complex 3 was evaluated by prompt gamma-ray analysis and alpha-autoradiography using the tumor-bearing rats. High accumulation of gadolinium was observed in the kidney and the %ID values were 0.17 and 0.088 at 20 and 60 min after injection of 3, respectively. The accumulation was also observed in the tumor and the %ID values were 0.010 and 0.0025 at 20 and 60 min after injection, respectively. The visualization experiment of boron distribution in the tumor-bearing rat by alpha-autoradiography indicates that boron was accumulated in the tumor and the intestines at 20 min after injection.  相似文献   

12.
Successful treatment of cancer by boron neutron capture therapy (BNCT) requires the selective delivery of (10)B to constituent cells within a tumor. The expression of the folate receptor is amplified in a variety of human tumors and potentially might serve as a molecular target for BNCT. In the present study we have investigated the possibility of targeting the folate receptor on cancer cells using folic acid conjugates of boronated poly(ethylene glycol) (PEG) containing 3rd generation polyamidoamine dendrimers to obtain (10)B concentrations necessary for BNCT by reducing the uptake of these conjugates by the reticuloendothelial system. First we covalently attached 12-15 decaborate clusters to 3rd generation polyamidoamine dendrimers. Varying quantities of PEG units with varying chain lengths were then linked to these boronated dendrimers to reduce hepatic uptake. Among all prepared combinations, boronated dendrimers with 1-1.5 PEG(2000) units exhibited the lowest hepatic uptake in C57BL/6 mice (7.2-7.7% injected dose (ID)/g liver). Thus, two folate receptor-targeted boronated 3rd generation polyamidoamine dendrimers were prepared, one containing approximately 15 decaborate clusters and approximately 1 PEG(2000) unit with folic acid attached to the distal end, the other containing approximately 13 decaborate clusters, approximately 1 PEG(2000) unit, and approximately 1 PEG(800) unit with folic acid attached to the distal end. In vitro studies using folate receptor (+) KB cells demonstrated receptor-dependent uptake of the latter conjugate. Biodistribution studies with this conjugate in C57BL/6 mice bearing folate receptor (+) murine 24JK-FBP sarcomas resulted in selective tumor uptake (6.0% ID/g tumor), but also high hepatic (38.8% ID/g) and renal (62.8% ID/g) uptake, indicating that attachment of a second PEG unit and/or folic acid may adversely affect the pharmacodynamics of this conjugate.  相似文献   

13.

Aim

The aim of this study is to assess the effect of the compositions of various soft tissues and tissue-equivalent materials on dose distribution in neutron brachytherapy/neutron capture therapy.

Background

Neutron brachytherapy and neutron capture therapy are two common radiotherapy modalities.

Materials and methods

Dose distributions were calculated around a low dose rate 252Cf source located in a spherical phantom with radius of 20.0 cm using the MCNPX code for seven soft tissues and three tissue-equivalent materials. Relative total dose rate, relative neutron dose rate, total dose rate, and neutron dose rate were calculated for each material. These values were determined at various radial distances ranging from 0.3 to 15.0 cm from the source.

Results

Among the soft tissues and tissue-equivalent materials studied, adipose tissue and plexiglass demonstrated the greatest differences for total dose rate compared to 9-component soft tissue. The difference in dose rate with respect to 9-component soft tissue varied with compositions of the materials and the radial distance from the source. Furthermore, the total dose rate in water was different from that in 9-component soft tissue.

Conclusion

Taking the same composition for various soft tissues and tissue-equivalent media can lead to error in treatment planning in neutron brachytherapy/neutron capture therapy. Since the International Commission on Radiation Units and Measurements (ICRU) recommends that the total dosimetric uncertainty in dose delivery in radiotherapy should be within ±5%, the compositions of various soft tissues and tissue-equivalent materials should be considered in dose calculation and treatment planning in neutron brachytherapy/neutron capture therapy.  相似文献   

14.
Previous studies have shown that some thioamides, e.g., thiouracil, are incorporated as false precursors into melanin during its synthesis. If boronated analogs of the thioamides share this property, the melanin of melanotic melanomas offers a possibility for specific tumoural uptake and retention of boron as a basis for neutron capture therapy. We report on the synthesis of boronated 1H-1,2,4-triazole-3-thiol (B-TZT), boronated 5-carboxy-2-thiouracil (B-CTU), and boronated 5-diethylaminomethyl-2-thiouracil (B-DEAMTU) and the localization of these substances in melanotic melanomas transplanted to mice. The distribution in the mice was studied by boron neutron capture radiography. B-TZT and B-CTU showed the highest tumour:normal tissue concentration ratios, with tumour:liver ratios of about 4 and tumour:muscle ratios of about 14; B-DEAMTU showed corresponding ratios of 1.4 and 5, respectively. The absolute concentration of boron in the tumours, however, was more than three times higher in the mice injected with B-TZT, compared with B-CTU. The results suggest that B-TZT may be the most promising compound of the three tested with regard to possible therapy of melanotic melanomas.  相似文献   

15.
Boron neutron capture therapy (BNCT) is currently undergoing clinical trials in the USA, Japan and The Netherlands with patients afflicted with deadly brain cancer (glioblastoma multiforme) or melanoma. This therapy relies on a binary process in which the capture of a slow neutron by a 10B nucleus leads to an energetic nuclear fission reaction, with the formation of 7Li3+ and 4He2+ and accompanied by about 2.4 MeV of energy. The fleeting 7Li3+ and 4He2+ travel a distance of only about the diameter of one cell, and they are deadly to any cell in which they have been produced. Research in progress is concerned with the development of advanced boron agents and neutron sources, other than nuclear reactors, for the treatment of a variety of cancer types using novel 10B delivery methods. Non-malignant diseases such as rheumatoid arthritis offer additional opportunities for BNCT. The entire BNCT area awaits commercialization.  相似文献   

16.
《Cytotherapy》2019,21(5):509-524
Cancer is the second leading cause of death in the world with a high annual incidence level. Researchers have been working on developing treatments for cancer. Targeted therapy is an emerging treatment modality that is more novel than surgery, radiotherapy and chemotherapy. In targeted therapy, exogenous nanoscale microparticles are applied as carriers for drugs or genes. However, conventional particles have certain limitations attributed to non-specific cytotoxicity, biocompatibility and low delivery efficacy in individual therapeutic vector systems. Exosomes are small vesicles secreted by various cells that consist of lipid bilayer membranes without organelles. Due to their excellent biocompatibility, exosomes have received increased attention in recent years for targeted therapy applications. This review briefly introduces the current status of targeted therapy, and exosomes are introduced by their structural characteristics, physiological effects and separation methods. This review also discusses the applications of engineered exosomes derived from different cells in the field of targeted therapies and compares the two-way regulation of mesenchymal stromal cell–derived exosomes in tumor therapy.  相似文献   

17.
To investigate the potential efficacy of fission neutrons from a fast-neutron reactor for the treatment of radioresistant tumors, the relative biological effectiveness (RBE) and tolerance dose of fission neutrons in canine skin were determined. The forelimbs of 34 healthy mongrel dogs received a single dose of fission neutrons (5.6, 6.8, 8.2, 9.6 or 11 Gy) or 137Cs gamma rays (10, 15, 20, 25 or 30 Gy). Based on observations of radiodermatitis for each radiation, the single-fraction RBE of fission neutrons in the sixth month was calculated as approximately 3. The tolerance doses of fission neutrons and gamma rays, defined as the highest doses giving no moist desquamation on the irradiated skin in the recovery phase, were estimated as 7.6 Gy and 20 Gy, respectively. The tolerance dose of 7.6 Gy of fission neutrons included 5.0 Gy of fast neutrons possessing high anti-tumor effects and 1.4 x 10(12) n/cm2 of thermal neutrons, which could be applicable to neutron capture therapy (NCT). The combination of fast-neutron therapy and NCT using a fast-neutron reactor might be useful for the treatment of radioresistant tumors.  相似文献   

18.
Reverse-biased silicon p-n junction arrays using Silicon-On-Insulator technology have been proposed as microdosimeters. The performance of such detectors in boron neutron capture therapy (BNCT) is discussed. This work provides the first reported measurements using boron-coated silicon diode arrays as microdosimeters in BNCT. Results are in good agreement with measurements with gas proportional counters. Various boron-coating options are investigated along with device orientation effects. Finally, a 235U coating is tested to simulate the behavior of the device in a heavy-ion therapy beam.  相似文献   

19.
Application of neutrons to cancer treatment has been a subject of considerable clinical and research interest since the discovery of the neutron by Chadwick in 1932 (3). Boron neutron capture therapy (BNCT) is a technique of radiation oncology which is used in treating brain cancer (glioblastoma multiform) or melanoma and that consists of preferentially loading a compound containing 10B into the tumor location, followed by the irradiation of the patient with a beam of neutron. Dose distribution for BNCT is mainly based on Monte Carlo simulations. In this work, the absorbed dose spatial distribution resultant from an idealized neutron beam incident upon ahead phantom is investigated using the Monte Carlo N-particles code, MCNP 4B. The phantom model used is based on the geometry of a circular cylinder on which sits an elliptical cylinder capped by half an ellipsoid representing the neck and head, both filled with tissue-equivalent material. The neutron flux and the contribution of individual absorbed dose components, as a function of depths and of radial distance from the beam axis (dose profiles) in phantom model, is presented and discussed. For the studied beam the maximum thermal neutron flux is at a depth of 2 cm and the maximum gamma dose at a depth of 4 cm.  相似文献   

20.
Boron neutron capture therapy (BNCT) represents a promising approach for tumor therapy. A critical requirement for BNCT is tumor targeting, a goal that is currently addressed with the development of low and high molecular weight agents capable of interacting with receptors expressed by cancer cells. Here, we describe a new bioconjugate (HApCB) composed by n-propyl carborane linked to hyaluronan (HA) via an ester linkage for a degree of substitution of approximately 30%, leading to a water-soluble derivative. The structure and main physicochemical characteristics of the new HA derivative were determined by means of Fourier transform infrared, fluorescence, and 1H, 13C, and 10B NMR analysis and are herein reported in detail. As HA is recognized by the CD44 antigen, densely populating the surface of many tumor cells, HApCB is expected to deliver boron atoms from the locally released carborane cages directly to target cells for antitumor application in BNCT. In vitro biological experiments showed that HApCB was not toxic for a variety of human tumor cells of different histotypes, specifically interacted with CD44 as the native unconjugated HA, and underwent uptake by tumor cells, leading to accumulation of amounts of boron atoms largely exceeding those required for a successful BNCT approach. Thus, HApCB may be regarded as a promising new BNCT agent for specific targeting of cancer cells overexpressing the CD44 receptor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号