首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Dried blood spot sampling is a promising and patient friendly alternative for venous sampling. A liquid chromatography tandem mass spectrometer assay was developed for analyzing cyclosporin A in dried blood spots. Linearity ranged from 25 to 1440 μg/L. Within and between run accuracy and precision were within limits. The developed assay has a negligible matrix-effect and a recovery of 97%. The dried blood spots were stable during a period of at least 17 days in the refrigerator. The developed assay is suitable for analyzing cyclosporin A in dried blood spots.  相似文献   

2.
Melamine was found to be the etiological factor for the urinary stones epidemic in infants and young children in China in 2008. Urine level of melamine and its analog cyanuric acid may be useful markers for the evaluation of toxic effects. Liquid chromatography tandem mass spectrometry methods for the individual determination of melamine and cyanuric acid in human urine are described. Using isotope labeled internal standards during liquid–liquid extraction, the method was fully validated by verifying specificity, linearity, LLOQ, intra- and inter-assay precision and accuracy, matrix effect, recovery and stability. Calibration curves with good linearity (r = 0.9999) over the concentration range from 10 to 5000 ng/ml, intra-assay precision <10% and inter-assay precision <15%, accuracy between 93.0 and 111.6% were obtained with multiple reaction monitoring mode for melamine and cyanuric acid in human urine. The methods were successfully applied to the analysis of urine samples collected from 86 infants and 110 adults.  相似文献   

3.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans.  相似文献   

4.
Dialkylphosphates (DAP) are urinary markers of the exposure to organophosphates pesticides. The aim of this study was to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantitative determination of the following DAP: dimethylphosphate (DMP), dimethythiophosphate (DMTP), dimethyldithiophosphate (DMDTP), diethylphosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP). Dibutylphosphate (DBP) was used as internal standard. This method was based on a liquid-liquid extraction procedure, a chromatographic separation using an Inertsil ODS3 C18 column and mass spectrometric detection in the negative ion, multiple reaction monitoring (MRM) mode, following two ion transitions per compound. It yielded a limit of quantification of 2 microg/L for the six compounds and intra-assay coefficients of variation (CV%) lower than 20%. This method was applied to the analysis of urines samples from a small cohort of non-exposed volunteers. At least one of the six DAP was detected in each sample. This result confirmed the feasibility of a LC-MS/MS procedure for monitoring the general population exposure to some frequently employed organophosphate pesticides.  相似文献   

5.
We present a fast and reproducible method for steroid analysis (corticosterone, deoxycorticosterone, progesterone, 17alpha-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, testosterone, dihydrotestosterone and cortisol) in small volumes of serum and in dried blood spot samples by LC-MS/MS. No derivatisation was needed. LC separation was achieved by using an Atlantis C18 column and water-methanol-formic acid gradient as a mobile phase and a flow rate of 250 microL/min over a run time of 6 min. Steroids were measured in MRM mode with electrospray interface (positive ion mode). Validation showed excellent precision, sensitivity, recovery and linearity with coefficients of determination r2>0.992.  相似文献   

6.
Liquid chromatographic/tandem mass spectrometric methods using pneumatically assisted electrospray ionisation (LC-ESI-MS/MS) was developed for determination of 18 mycotoxins and metabolites-ochratoxin A, zearalenone, alpha-zearalenol, beta-zearalenol, alpha-zearalanol (zeranol), beta-zearalanol (taleranol), fumonisin B1, fumonisin B2, T-2 toxin, HT-2 toxin, T-2 triol, diacetoxyscirpenol (DAS), 15-monoacetoxyscirpenol (MAS), deoxynivalenol (DON), 3-acetyldeoxynivalenol (3-AcDON), 15-acetyldeoxynivalenol (15-AcDON), deepoxy-deoxynivalenol (DOM-1) and aflatoxin M1--in milk. The mycotoxins were extracted and cleaned up simultaneously. Extraction and removal of lipophilic compounds was performed at pH 2 using a two-phase mixture of acetonitrile and hexane. The acetonitrile concentration of the aqueous phase was reduced and the pH was adjusted to 8.5 before clean up by solid phase extraction (SPE) on Oasis HLB. The toxins DON, DOM-1, 3-AcDON, 15-AcDON, ochratoxin A, zearalenone, alpha-zearalenol, beta-zearalenol, alpha-zearalanol and beta-zearalanol were detected in negative ion mode after separation on a Hypersil ENV analytical column, while the toxins T-2 toxin, HT-2 toxin, T-2 triol, DAS, MAS, fumonisin B1, fumonisin B2 and aflatoxin M1 were detected in positive ion mode after separation on a Luna C18 column. Two transition products were monitored for each compound. The extraction and SPE conditions were optimised to obtain maximum recovery and minimum signal suppression/enhancement. The detection capabilities related to the transition products of lowest abundance were in the range 0.020-0.15 microg/l. The mean true recoveries were in the range 76-108% at levels of 0.2-10 microg/l.  相似文献   

7.
Myo-inositol plays key physiological functions, necessitating development of methodology for quantification in biological matrices. Limitations of current mass spectrometry-based approaches include the need for a derivatisation step and/or sample clean-up. In addition, co-elution of glucose may cause ion suppression of myo-inositol signals, for example in blood or urine samples. We describe an HPLC-MS/MS method using a lead-form resin based column online to a triple quadrupole tandem mass spectrometer, which requires minimum sample preparation and no derivatisation. This method allows separation and selective detection of myo-inositol from other inositol stereoisomers. Importantly, inositol was also separated from hexose monosaccharides of the same molecular weight, including glucose, galactose, mannose and fructose. The inter- and intra-assay variability was determined for standard solutions and urine with inter-assay coefficient of variation (CV) of 1.1% and 3.5% respectively, while intra-assay CV was 2.3% and 3.6%. Urine and blood samples from normal individuals were analysed.  相似文献   

8.
The aim of the project was to develop a fast and reliable method for the quantification of the three tetracyclines: tetracycline, oxytetracycline and chlortetracycline in urine. The method is based on column-switching high-performance liquid chromatography with detection by MS–MS. Buffer is added to the sample before it is injected into the chromatographic system, and the first column which is an internal surface reversed-phase column separates the tetracyclines from the bulk of other compounds in urine. The tetracyclines are collected and concentrated on the analytical column before they are separated and eluted into the mass spectrometer in which the tetracycline are detected. The mass spectrometer is a triple quadrupole instrument and is equipped with an electrospray ion source. The MH+ ions are selected in the first quadrupole and collisionally activated in the collision cell. Upon collision, activation all three tetracyclines form fragment ions which could be assigned as: [M+H–H2O–NH3]+ which are selected in the sond mass filter. The detection limits for all three tetracyclines are about 10 ppb, and the calibration curves are linear from 10 to 1000 ppb.  相似文献   

9.
10.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

11.
The determination of residues of benzimidazole using liquid chromatography and tandem mass spectrometry (LC–MS–MS) with ion spray ionization is described. Swine muscle tissue was spiked with a mixture of fifteen benzimidazoles, including metabolites of fenbendazole and albendazole. As clean-up procedure, an ethyl acetate extraction followed by solid-phase extraction on styrol-divinyl-benzene cartridge was used. The evaluation was performed by selecting the characteristic product ions for the benzimidazoles and using multiple reaction mode. 2-n-Butylmercaptobenzimidazole was used as internal standard. Blank muscle samples were fortified in the concentration range of 1–22 μg/kg. The limits of detection were below 6 μg/kg and the limits of quantification for most benzimidazoles were below 10 μg/kg. The matrix effect was checked using spiked muscle tissues of cattle and sheep as well as liver of cattle. Practical application will be shown by incurred egg material from laying hens treated with flubendazole. The recovery of the clean-up was mostly above 50% in muscle tissue and 70% in egg yolk.  相似文献   

12.
A sensitive, reproducible, and rapid analytical method for the analysis of trace-level heterocyclic amines (HCAs) that are expected to have high levels of human exposure was developed. Liquid–liquid extraction (LLE) with dichloromethane (DCM) followed by solid-phase extraction (SPE) was carried out. Liquid extraction with DCM under basic conditions was efficient in extracting HCAs from urine samples. For further purification, mixed mode cationic exchange (MCX) cartridges were applied to eliminate the remaining interferences after liquid extraction. Separation and quantification were performed by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) in selected reaction monitoring (SRM) mode. The overall recoveries ranged between 71.0% and 113.6% with relative standard deviations (RSDs) of 5.1% to 14.7% for the entire procedure. The limits of detection (LODs) and limits of quantification (LOQs) of the proposed analytical method were in the ranges of 0.04 to 0.10 ng/ml and 0.15 to 0.36 ng/ml, respectively. This method was applied to the analysis of monitoring in urine samples for Korean school children, and the results demonstrated that the method can be used for the trace determination of HCAs in urine samples.  相似文献   

13.
We have studied rapid and simple sugar mapping using liquid chromatography/electrospray ionization mass spectrometry (LC/MS) equipped with a graphitized carbon column. The oligosaccharide mixture was separated on the basis of the sequence, branching structure, and linkage, and each oligosaccharide was characterized based on its molecular mass. In this study we demonstrated the usefulness of capillary LC/MS (CapLC/MS) and capillary liquid chromatography/tandem mass spectrometry (CapLC/MS/MS) as sensitive means for accomplishing the structural analysis of oligosaccharides in a low-abundance glycoprotein. The carbohydrate heterogeneity and molecular mass information of each oligosaccharide can be readily obtained from CapLC/MS of a small amount of glycoprotein. CapLC/MS/MS provided b-ion series, which is informative with regard to monosaccharide sequence. Exoglycosidase digestion followed by CapLC/MS elucidated a carbohydrate residue linkage. Using this method, we characterized N-linked oligosaccharides in hepatocyte growth factor produced in mouse myeloma NS0 cells as the complex-type bi-, tri-, and tetraantennary terminated with N-glycolylneuraminic acids and alpha-linked galactose residues. Sugar mapping with CapLC/MS and CapLC/MS/MS is useful for monitoring glycosylation patterns and for structural analysis of carbohydrates in a low-abundance glycoprotein and thus will become a powerful tool in biological, pharmaceutical, and clinical studies.  相似文献   

14.
The rodenticide monofluoroacetate (MFA) and monochloroacetate (MCA), a chemical intermediate from several chemical syntheses, have been identified as potential agents of chemical terrorism due to their high toxicity. In preparation for response to poisonings and mass exposures, we have developed a quantification method using isotopic dilution to determine MFA and MCA in urine from 50 to 5000 ng/mL. Both analytes were extracted from urine using solid-phase extraction; extraction recoveries were 62% (MFA) and 76% (MCA). The extracts were then separated with isocratic high-performance liquid chromatography and identified using electrospray ionization tandem mass spectrometry, with detection limits of 0.9 and 7.0 ng/mL for MFA and MCA, respectively. Selectivity was established for both analytes with unique chromatographic retention times which were correlated with isotopically labeled internal standards and the use of two mass spectral transitions for each compound. The intra-day variability was less than 5% for both analytes and the inter-day variability was 7% for MFA and 6% for MCA.  相似文献   

15.
AIM: In forensic toxicology it is important to have specific and sensitive analysis for quantification of illicit drugs in biological matrices. This paper describes a quantitative method for determination of cocaine and its major metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and urine by liquid chromatography coupled with tandem mass spectrometry LC/MS/MS. METHOD: The sample pre-treatment (0.20 g) consisted of acid precipitation, followed by centrifugation and solid phase extraction of supernatant using mixed mode sorbent columns (SPEC MP1 Ansys Diag. Inc.). Chromatographic separation was performed at 30 degrees C on a reverse phase Zorbax C18 column with a gradient system consisting of formic acid, water and acetonitrile. The analysis was performed by positive electrospray ionisation with a triple quadropole mass spectrometer operating in multiple reaction monitoring (MRM) mode. Two MRM transitions of each analyte were established and identification criteria were set up based on the retention time and the ion ratio. The quantification was performed using deuterated internal analytes of cocaine, benzoylecgonine and ecgonine methyl ester. The calibration curves of extracted standards were linear over a working range of 0.001-2.00 mg/kg whole blood for all analytes. The limit of quantification was 0.008 mg/kg; the interday precision (measured by relative standard deviation-%RSD) was less than 10% and the accuracy (BIAS) less than 12% for all analytes in whole blood. Urine samples were estimated semi-quantitatively at a cut-off level of 0.15 mg/kg with an interday precision of 15%. CONCLUSION: A liquid chromatography mass spectrometric (LC/MS/MS) method has been developed for confirmation and quantification of cocaine and its metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and semi-quantitative in urine. The method is specific and sensitive and offers thereby an excellent alternative to other methods such as GC-MS that involves derivatisation.  相似文献   

16.
The applicability of LC–MS/MS in precursor ion scan mode for the detection of urinary stanozolol metabolites has been studied. The product ion at m/z 81 has been selected as specific for stanozolol metabolites without a modification in A- or N-rings and the product ions at m/z 97 and 145 for the metabolites hydroxylated in the N-ring and 4-hydroxy-stanozolol metabolites, respectively. Under these conditions, the parent drug and up to 15 metabolites were found in a positive doping test sample. The study of a sample from a chimeric uPA-SCID mouse collected after the administration of stanozolol revealed the presence of 4 additional metabolites. The information obtained from the product ion spectra was used to develop a SRM method for the detection of 19 compounds. This SRM method was applied to several doping positive samples. All the metabolites were detected in both the uPA-SCID mouse sample and positive human samples and were not detected in none of the blank samples tested; confirming the metabolic nature of all the detected compounds. In addition, the application of the SRM method to a single human excretion study revealed that one of the metabolites (4ξ,16ξ-dihydroxy-stanozolol) could be detected in negative ionization mode for a longer period than those commonly used in the screening for stanozolol misuse (3′-hydroxy-stanozolol, 16β-hydroxy-stanozolol and 4β-hydroxy-stanozolol) in doping analysis. The application of the developed approach to several positive doping samples confirmed the usefulness of this metabolite for the screening of stanozolol misuse. Finally, a tentative structure for each detected metabolite has been proposed based on the product ion spectra measured with accurate masses using UPLC–QTOF MS.  相似文献   

17.
High-performance liquid chromatography with on-line electrospray ionization mass spectrometry (ESI-LC/MS) was investigated for the analysis of carbohydrate heterogeneity using RNase B as a model glycoprotein. Oligosaccharides released from RNase B with endoglycosidase H were reduced and separated on a graphitized carbon column (GCC). GCC-HPLC/MS in the positive-ion mode was successful in the identification of one Man5GlcNAc, three Man6GlcNAc, three Man7GlcNAc, three Man8GlcNAc, one Man9GlcNAc, and an oligosaccharide having six hexose units (Hex) and two N-acetylhexosamine units (HexNAc). The branch structures of the three Man7GlcNAc isomers were determined by liquid chromatography with tandem mass spectrometry (LC/MS/MS). LC/MS/MS analysis was shown to be useful for the detection and identification of a trace amount of Hex6HexNAc2 alditol as a hybrid-type oligosaccharide. Its structure was confirmed by the combination of LC/MS with enzymatic digestion using beta-galactosidase and N-acetyl-beta-glucosaminidase. The relative quantities of high-mannose-type oligosaccharides in RNase B detected by ESI-LC/MS are in reasonable agreement with those by UV, high-pH anion-exchange chromatography with pulsed amperometric detection, fluorophore-assisted carbohydrate electrophoresis. Our results indicate that LC/MS and LC/MS/MS can be utilized to elucidate the distribution of oligosaccharides and their structures, which differ in molecular weight, sugar sequence, and branch structure.  相似文献   

18.
The applicability of LC–MS/MS in precursor ion scan mode for the detection of urinary stanozolol metabolites has been studied. The product ion at m/z 81 has been selected as specific for stanozolol metabolites without a modification in A- or N-rings and the product ions at m/z 97 and 145 for the metabolites hydroxylated in the N-ring and 4-hydroxy-stanozolol metabolites, respectively. Under these conditions, the parent drug and up to 15 metabolites were found in a positive doping test sample. The study of a sample from a chimeric uPA-SCID mouse collected after the administration of stanozolol revealed the presence of 4 additional metabolites. The information obtained from the product ion spectra was used to develop a SRM method for the detection of 19 compounds. This SRM method was applied to several doping positive samples. All the metabolites were detected in both the uPA-SCID mouse sample and positive human samples and were not detected in none of the blank samples tested; confirming the metabolic nature of all the detected compounds. In addition, the application of the SRM method to a single human excretion study revealed that one of the metabolites (4ξ,16ξ-dihydroxy-stanozolol) could be detected in negative ionization mode for a longer period than those commonly used in the screening for stanozolol misuse (3′-hydroxy-stanozolol, 16β-hydroxy-stanozolol and 4β-hydroxy-stanozolol) in doping analysis. The application of the developed approach to several positive doping samples confirmed the usefulness of this metabolite for the screening of stanozolol misuse. Finally, a tentative structure for each detected metabolite has been proposed based on the product ion spectra measured with accurate masses using UPLC–QTOF MS.  相似文献   

19.
Sugammadex (Bridion?, Merck Sharp & Dohme Corp., Oss, The Netherlands) is a modified γ-cyclodextrin which has the ability to reverse the neuromuscular blockade induced by the steroidal neuromuscular blocking agents rocuronium and vecuronium. The objective of the current study is to describe the bioanalytical methods that have been developed and validated according to US Food and Drug Administration guidelines on bioanalytical method validation, and subsequently applied to determine total sugammadex (i.e., free sugammadex plus sugammadex bound to the neuromuscular blocking agent) in human heparinized plasma, urine and dialysate. Sugammadex was extracted from human plasma and urine using solid phase extraction with Isolute HAX 96-well extraction plates; no extraction was performed on dialysate samples. Samples from plasma, urine, and dialysate were analyzed on a Polaris? C18-A PEEK (polyaryletheretherketone) analytical column (50 mm × 4.6 mm internal diameter, 5 μm) with a linear mobile phase gradient of 0.1% (v/v) formic acid in water:methanol from 70:30 to 20:80. The flow rate was 1 mL/min with a total run time for each injection of 6 min. Tandem mass spectrometric detection was conducted using multiple reaction monitoring under negative ion mode with a turbo ion-spray interface to quantify the concentration of sugammadex. Inter- and intra-assay precision and accuracy were within pre-defined acceptance limits. The presence of rocuronium did not interfere with the assay in plasma, urine or dialysate; similarly, vecuronium did not interfere with the plasma assay (not tested for interference in urine or dialysate). Sugammadex was found to be stable in plasma, urine and dialysate in the short-term at room temperature, in the long-term at -20°C, and after several freeze/thaw cycles. The validated bioanalytical methods developed here have been successfully applied in a series of clinical studies for the determination of total sugammadex in plasma, urine and dialysate.  相似文献   

20.
Higenamine is an active ingredient of Aconite root in Chinese herbal medicine and might be used as a new agent for a pharmaceutical stress test and was approved to undergo clinical pharmacokinetic study. Therefore, there exists a need to establish a sensitive and rapid method for the determination of higenamine in human plasma and urine. This paper described a sensitive and rapid method based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the determination of higenamine in human plasma and urine. Solid-phase extraction (SPE) was used to isolate the compounds from biological matrices followed by injection of the extracts onto an Atlantis dC18 column with isocratic elution. The mobile phase was 0.05% formic acid in water-methanol (40:60, v/v). The mass spectrometry was carried out using positive electrospray ionization (ESI) and data acquisition was carried out in the multiple reaction monitoring (MRM) mode. The method was fully validated over the concentration range of 0.100-50.0 ng/mL and 1.00-500 ng/mL in plasma and urine, respectively. The lower limits of quantification (LLOQs) were 0.100 and 1.00 ng/mL in plasma and urine, respectively. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115% for both plasma and urine. Extraction recovery was 82.1% and 56.6% in plasma and urine, respectively. Selectivity, matrix effects and stability were also validated in human plasma and urine. The method was applied to the pharmacokinetic study of higenamine hydrochloride in Chinese healthy subjects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号