首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe an isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of succinylacetone (SA) in urine for the diagnosis of hepatorenal tyrosinemia (HT1). The method used 15N-labeled 5(3)-methyl-3(5)-isoxazole propionic acid as internal standard. Urine samples were oximated with hydroxylamine hydrochloride at 80 degrees C, extracted by solvent-solvent extraction, and followed by derivatization of the butyl ester. The butylated isoxazole derivatives of SA and its internal standard were detected and quantified using positive ion electrospray LC-MS/MS with selected reaction monitoring. The turnaround time between injections was 10 min. Calibration curves were linear over the range of 0.0633-63.3 micromol/L. The intra- and interday assay variations were less than 7%. Mean recoveries of SA at three different concentrations ranged from 96 to 109%. During the course of this study, we identified 12 new patients with HT1 and applied this method to follow up the treatment of 4 of these patients as well as previously diagnosed HT1 patients.  相似文献   

2.
The chemical diagnosis of tyrosinemia type I generally involves the detection of succinylacetone (SA) in patient urine. However, 5-aminolevulinate (5ALA), which accumulates due to succinylacetone's inhibition of porphyrin synthesis, can also be used as diagnostic metabolites. Here we examined the stabilities of these markers on dried urine filter paper. After two weeks at room temperature, the succinylacetone was 10% of its original level, but over 80% of 5-aminolevulinate remained. Thus, although insufficient succinylacetone was recovered from dried urine filter paper to diagnose tyrosinemia type I, 5-aminolevulinate was readily detected, permitting the diagnosis.  相似文献   

3.
A method for the simultaneous direct determination of salicylate (SA), its labile, reactive metabolite, salicyl acyl glucuronide (SAG), and two other major metabolites, salicyluric acid and gentisic acid in plasma and urine is described. Isocratic reversed-phase high performance liquid chromatography (HPLC) employed a 15-cm C18 column using methanol-acetonitrile-25 mM acetic acid as the mobile phase, resulting in HPLC analysis time of less than 20 min. Ultraviolet detection at 310 nm permitted analysis of SAG in plasma, but did not provide sensitivity for measurement of salicyl phenol glucuronide. Plasma or urine samples are stabilized immediately upon collection by adjustment of pH to 3–4 to prevent degradation of the labile acyl glucuronide metabolite. Plasma is then deproteinated with acetonitrile, dried and reconstituted for injection, whereas urine samples are simply diluted prior to injection on HPLC. m-Hydroxybenzoic acid served as the internal standard. Recoveries from plasma were greater than 85% for all four compounds over a range of 0.2–20 μg/ml and linearity was observed from 0.1–200 μg/ml and 5–2000 μg/ml for SA in plasma and urine, respectively. The method was validated to 0.2 μg/ml, thus allowing accurate measurement of SA, and three major metabolites in plasma and urine of subjects and small animals administered salicylates. The method is unique by allowing quantitation of reactive SAG in plasma at levels well below 1% that of the parent compound, SA, as is observed in patients administered salicylates.  相似文献   

4.
A sensitive and accurate stable isotope dilution GC/MS assay was developed and validated for the quantification of succinylacetone (SA) in plasma and amniotic fluid (AF). SA is pathognonomic for tyrosinemia type I, a genetic disorder caused by a reduced activity of fumarylacetoacetate hydrolase (FAH). In untreated patients, SA can easily be measured in plasma and urine because the expected concentrations are in the micromol/L range. Due to a founder effect, the province of Quebec has an unusually high prevalence of tyrosinemia type I, hence, the quantification of SA in AF or plasma of treated patients in the nmol/L range becomes very useful. The method utilizes 13C5-SA as an internal standard and a three-step sample treatment consisting of oximation, solvent extraction and TMCS derivatization. The assay was validated by recording the ion intensities of m/z 620 for SA and m/z 625 for ISTD in order to demonstrate the precision of measurements, the linearity of the method, limit of quantification and detection (LOQ and LOD), specificity, accuracy, as well as metabolite stability. Values for the intra-day assays ranged from 0.2 to 3.2% while values for the inter-day assays ranged from 1.9 to 5.6% confirming that the method has good precision. A calibration plot using SA detected by GC/MS gave excellent linearity with a correlation coefficient of 0.999 over the injected concentration range of 5-2000 nmol/L. LOQ and LOD were 3 and 1 nmol/L, respectively. The usefulness of this method was demonstrated by SA quantification in an AF sample of an affected fetus and in plasma of patients treated with NTBC. The results demonstrate that this novel GC/MS method may be a valuable tool for metabolic evaluation and clinical use.  相似文献   

5.
We have characterized a new mutant strain of mouse that has hypertyrosinemia. The blood tyrosine level was persistently high, and increased amounts of 4-hydroxyphenylpyruvic acid and its derivatives were excreted into the urine. Succinylacetone was not detected in urine samples from these mice. All the animals were apparently healthy, and there was no evidence of hepatorenal dysfunction. The hypertyrosinemia was transmitted through an autosomal recessive inheritance. Analyses of hepatic enzymes related to tyrosine metabolism revealed that 4-hydroxyphenylpyruvic acid dioxygenase activity was virtually absent, while fumarylacetoacetase and tyrosine aminotransferases (cytosolic and mitochondrial forms) were normal in these mutant mice. Immunoblot analysis of 4-hydroxyphenylpyruvic acid dioxygenase protein in the liver indicated that the subunit protein of the enzyme was absent. It would appear that hypertyrosinemia in this mutant strain was caused by a genetic defect in 4-hydroxyphenylpyruvic acid dioxygenase. These features are similar to type III tyrosinemia in humans. Analysis of this mutant strain of mouse is expected to provide valuable information on the pathogenesis of human type III tyrosinemia and can also serve as a useful system for studies on tyrosine metabolism.  相似文献   

6.
Adult rats were orally administered with a single dose of sanguinarine (10 mg SA per 1 kg body weight) in 1.0 ml water. In the plasma and the liver, dihydrosanguinarine (DHSA) was identified as a SA metabolite by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC/ESI-MS). Significantly higher levels of DHSA were found in both the plasma and the liver in comparison with those of SA. SA and DHSA were not detected in the urine. The formation of DHSA might be the first step of SA detoxification in the organism and its subsequent elimination in phase II reactions. Benz[c]acridine (BCA), in the literature cited SA metabolite, was found neither in urine nor in plasma and liver.  相似文献   

7.
A high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) method has been developed and validated for the quantitative analysis of NIM811, a cyclophilin inhibitor, in human dried blood spot (DBS) samples, which were produced by spotting 20 μl whole blood onto FTA cards. A 3mm disc was cut from the DBS samples and extracted using methanol, followed by liquid-liquid extraction with MTBE. The reconstituted extracts were chromatographed using a Halo C(18) column and gradient elution for MS/MS detection. The possible impact of hematocrit, blood sample volume and punching location on DBS sampling was investigated. The results showed that blood sample volume or punching location has no impact on assay performance, but the presence of a high hematocrit resulted in significantly increased analyte concentrations measured from the high QC samples. The current method was fully validated over the range of 10.0-5000 ng/ml with correlation coefficients (r(2)) for three validation batches equal to or better than 0.991. The accuracy and precision (CV) at the LLOQ were -0.7 to 6.0% bias of the nominal value (10.0 ng/ml) and 10.2-2.3%, respectively. For the balance of QC samples (20.0, 50.0, 750, 1500 and 3750 ng/ml), the precision (CV) ranged from 3.2 to 11.7% and from 5.6 to 10.2%, respectively, for the intra-day and inter-day evaluations. The accuracy ranged from -6.8 to 8.5% and -0.2% to 2.7% bias, respectively, for the intra-day and inter-day batches. NIM811 is stable in the DBS samples for at least 24h at room temperature and 4h at 60°C. Interestingly, the long term stability (LTS) assessment showed that the stability of the analyte is better when the DBS samples were stored at a lower storage temperature (e.g. ≤ -60°C) compared to storage at room temperature. This is probably due to the interaction of the additives and/or other materials (e.g. cellulose, etc) on the DBS card with NIM811, a cyclic peptide. The current methodology has been applied to determine the NIM811 levels in DBS samples prepared from a clinical study.  相似文献   

8.
14C-salicylic acid (SA) was used to monitor SA metabolism and its regulation in tobacco cell suspension culture. Two SA concentrations (20 microM and 200 microM) were used for comparison. SA was quickly taken up in both treatments, and the 200 microM-treated cells absorbed approximately 15 times that of 20 microM-treated cells within 5 min. More than 85% and 50% of the absorbed SA were excreted in free form to the culture medium within 5 h from cells treated with 200 microM and 20 microM SA, respectively. SA excretion was significantly inhibited by EGTA and the inhibition could be reversed by the addition of exogenous Ca2+ to the culture medium in the 200 microM SA treatment. However, EGTA had little or no effect on SA excretion in the 20 microM SA treatment. The data suggest that tobacco suspension-cultured cells may contain both Ca2+-dependent and Ca2+-independent pathways for SA excretion. Reduced glutathione (an active oxygen species scavenger), staurosporine (a protein kinase inhibitor), and cycloheximide (an inhibitor of de novo protein synthesis) also blocked intracellular SA excretion to the culture medium in the 200 microM but not in the 20 microM SA treatment. These data support the existence of alternative SA excretion pathways in tobacco suspension-cultured cells. Tobacco cells may use both Ca2+-dependent and Ca2+-independent excretion pathways to cope with different intracellular SA status, and the pathway influenced by EGTA, reduced glutathione, staurosporine, and cycloheximide is activated by SA at 200 microM, but not at 20 microM.  相似文献   

9.
Studies were conducted to determine the comparative effects of tocopherols and tocotrienols on preneoplastic (CL-S1), neoplastic (-SA), and highly malignant (+SA) mouse mammary epithelial cell growth and viability in vitro. Over a 5-day culture period, treatment with 0-120 microM alpha- and gamma-tocopherol had no effect on cell proliferation, whereas growth was inhibited 50% (IC50) as compared with controls by treatment with the following: 13, 7, and 6 microM tocotrienol-rich-fraction of palm oil (TRF); 55, 47, and 23 microM delta-tocopherol; 12, 7, and 5 microM alpha-tocotrienol; 8, 5, and 4 microM gamma-tocotrienol; or 7, 4, and 3 microM delta-tocotrienol in CL-S1, -SA and +SA cells, respectively. Acute 24-hr exposure to 0-250 microM alpha- or gamma-tocopherol (CL-S1, -SA, and +SA) or 0-250 microM delta-tocopherol (CL-S1) had no effect on cell viability, whereas cell viability was reduced 50% (LD50) as compared with controls by treatment with 166 or 125 microM delta-tocopherol in -SA and +SA cells, respectively. Additional LD50 doses were determined as the following: 50, 43, and 38 microM TRF; 27, 28, and 23 microM alpha-tocotrienol; 19, 17, and 14 microM gamma-tocotrienol; or 16, 15, or 12 microM delta-tocotrienol in CL-S1, -SA, and +SA cells, respectively. Treatment-induced cell death resulted from activation of apoptosis, as indicated by DNA fragmentation. Results also showed that CL-S1, -SA, and +SA cells preferentially accumulate tocotrienols as compared with tocopherols, and this may partially explain why tocotrienols display greater biopotency than tocopherols. These data also showed that highly malignant +SA cells were the most sensitive, whereas the preneoplastic CL-S1 cells were the least sensitive to the antiproliferative and apoptotic effects of tocotrienols, and suggest that tocotrienols may have potential health benefits in preventing and/or reducing the risk of breast cancer in women.  相似文献   

10.
A quantitative liquid chromatography positive ion electrospray tandem mass spectrometric method for the simultaneous determination of sulforaphane, iberin and their metabolites in human urine and plasma is described. The stability of the metabolites was determined in aqueous solution and in human plasma. Gradient liquid chromatographic separation was performed on a Zorbax SB-Aq 3.5 microm (100 x 2.1mm) column, using a mobile phase (flow rate 0.25 mL/min) consisting of ammonium acetate buffer at pH 4 and acetonitrile. Butyl thiocarbamoyl l-cysteine was used as internal standard. The assay was linear (r(2)>0.99) over the range of 0.03-300 microM in urine and 0.03-15 microM in plasma with intra- and inter-day assay precision (<10% CV) and accuracy (<20%). The lower limits of quantitation were in the range of 10-150 nmol/L. The method has been used to report, for the first time, individual quantitative measurement of each of the mercapturic acid pathway metabolites of sulforaphane and iberin in both human plasma and urine following a dietary study of broccoli consumption.  相似文献   

11.
Supported liquid membrane (SLM) technique for sample work-up and enrichment was used for determination of tricyclic antidepressant drugs in urine by high-performance liquid chromatography (HPLC) with UV detection. The studied antidepressant drugs were amitriptyline, opipramol, noxiptyline and additionally diethazine was used as possible internal standard. Alkaline phosphoric buffer with urine sample, as the donor solution, was passed over the liquid membrane into which investigated substances were extracted. On the other side of the membrane, analyzed compounds were trapped due to creating non-extractable form in acidic acceptor solution. Enriched and cleaned up drugs were then injected into a HPLC system with ultraviolet detection to analyze of their concentration in acceptor solution. Optimum extraction efficiency was determined by changing acceptor and donor solutions pH, application of different flow rates of donor solution and by using different solvents in the membrane. Also, donor solution volume, extraction time and concentration of analytes were varied to check the linearity of extraction process. The highest extraction efficiency: 43% for opipramol, 56% for noxiptyline, 43% for amitriptyline and 42% for diethazine (R.S.D. values were <6% and n=3) was achieved when 0.05 M phosphate buffer pH 4.0 and 9.5 were used as donor and acceptor solutions, respectively, n-undecane with 5% tri-n-octylphosphine oxide (TOPO) was used as liquid membrane. Limit of quantification (LOQ) for tricyclic antidepressants after enrichment of 100ml of urine sample was about 1 ng/ml.  相似文献   

12.
Ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction (UA IL-DLLME) coupled with high-performance liquid chromatography (HPLC) has been developed for the determination of celastrol in human urine samples. In the microextraction procedure, ionic liquid (IL) was used as extraction solvent and dispersed into the aqueous sample solution as fine droplets by means of dispersive solvent and ultrasonication which promoted the analyte to migrate into IL phase more easily. Several important parameters affecting the extraction efficiency were studied and optimized, including the type and volume of extraction solvent and dispersive solvent, sample pH, ultrasonication time, cooling time, centrifugation time and salting-out effect. Under the optimized conditions, 110-fold enrichment factor was obtained and the limit of detection (LOD) was 1.6 μg/L at a signal-to-noise ratio of 3. The calibration curve was linear over the range of 10-1000 μg/L for celastrol in human urine sample, with a correlation coefficient of 0.9980. Intra- and inter-assay precision were 0.43% and 2.78%, respectively. The proposed method was successfully applied to the real human urine samples and good spiked recoveries in the range of 93.2-109.3% were obtained.  相似文献   

13.
As the epidemiological and physiological investigation of isoflavones and lignans expands, the need for sensitive methods for analyzing large numbers of samples intensifies. We have developed a method using high-performance liquid chromatography (HPLC) equipped with a coulometric electrode array detector for separation and sensitive detection of daidzein (Da), equol (Eq), genistein (Ge) and enterolactone (Enl) in dried blood spots (DBS). Detection limits ranged from 4.5 pg or 0.09 ng/mL (Eq) to 19 pg or 0.38 ng/mL (Ge) on column. Signal linearities ranged from detection limits to 200 ng/mL (Eq, Enl) and 600 ng/mL (Da, Ge) sample concentration. Correlations between DBS and serum concentrations were 0.66 (Enl), 0.88 (Eq), 0.98 (Ge) and 0.99 (Da). Intra-assay coefficients of variation (CVs) were less than 8% and inter-assay CVs ranged from 2.4 to 20.2% for Da, Eq and Ge for three levels of controls. Enl intra-assay CV was 13.6% for the low pooled control. Analytic recovery ranged from 87% (inter-assay Ge) to 98% (inter-assay Enl). DBS concentrations of Da, Ge and Eq were stable for at least 8 weeks at 4 and 25 degrees C, and at 37 degrees C for at least 5 weeks, with Enl showing greater variability at all temperatures but relative stability for 7 weeks. Measurement of samples from 135 perimenopausal Japanese women consuming habitual diets in Kyoto and Fukushima prefectures showed the former to have the expected lower concentrations of Da and Eq (416 and 87 nM) as well as Enl (49 nM) compared to the latter locale (566, 145 and 72 nM, respectively). This method could be useful in large epidemiological research or detailed physiological studies.  相似文献   

14.
A simple method, exposure to natural-light, was developed to remove riboflavin from urine to enhance its use as the biological matrix for the preparation of calibration and control samples. Riboflavin-depleted urine containing less than 1 ng/ml of riboflavin was used to validate a high-performance liquid chromatography with fluorescence detection method for the determination of urinary riboflavin. The linearity of the assay (r2=0.999) was acceptable over the range of 10-5000 ng/ml. The intra-assay and inter-assay CVs were 3.3% and 9%, respectively. Subsequent stability studies found that urine riboflavin was stable for up to 6 months at 4 or -20 degrees C.  相似文献   

15.
A method based on liquid chromatography (LC) in combination with mass spectrometry (MS) for the analysis of alachlor (ALA) and its metabolites, 2-chloro-N-[2,6-diethylphenyl]acetamide (CDEPA) and 2,6-diethylaniline (DEA), in rat plasma and urine has been developed. 13C-labeled ALA was used as the internal standard for quantitation. The analyte in plasma or urine was isolated using a Waters Oasis HLB extraction plate. The mass spectrometer was operated in the ESI MS-SIM mode with a programming procedure. The retention times for ALA, CDEPA and DEA were 1.84, 3.11 and 4.12 min, respectively. The limits of quantification (LOQ) for ALA, CDEPA and DEA were 2.3, 0.8 and 0.8 ng per injection, respectively. The linear fit of analyte to mass response had an R2 of 0.99. Reproducibility of the sample handling and LC-MS analysis had a RSD of < or = 10%. The average recoveries for these analytes in rat plasma were better than 90%. Similar results were obtained with rat urine.  相似文献   

16.
Succinylacetone (SA), a metabolic end-product found in urine from individuals with hereditary tyrosinemia and associated renal Fanconi syndrome and a known inhibitor of hepatic 5-aminolevulinic acid dehydratase (ALAD), has been used to study heme metabolism in isolated rat renal tubules. Heme biosynthetic porphyrin precursors are increased selectively in the presence of 4 mmol/1 SA. Total porphyrin content of the tubules are increased approximately 2-fold, while both ferrochelatase and heme oxygenase activities remain unaffected by SA. Nonetheless, total heme content is reduced, as was incorporation of radioactive label from amino[14C]levulinic acid. Cytochrome P-450 content remained unaffected. Impairment of iron uptake and/or transport within the cell or enhancement of heme catabolism via a non-heme oxygenase-dependent pathway could explain the observations.  相似文献   

17.
Higenamine is an active ingredient of Aconite root in Chinese herbal medicine and might be used as a new agent for a pharmaceutical stress test and was approved to undergo clinical pharmacokinetic study. Therefore, there exists a need to establish a sensitive and rapid method for the determination of higenamine in human plasma and urine. This paper described a sensitive and rapid method based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for the determination of higenamine in human plasma and urine. Solid-phase extraction (SPE) was used to isolate the compounds from biological matrices followed by injection of the extracts onto an Atlantis dC18 column with isocratic elution. The mobile phase was 0.05% formic acid in water-methanol (40:60, v/v). The mass spectrometry was carried out using positive electrospray ionization (ESI) and data acquisition was carried out in the multiple reaction monitoring (MRM) mode. The method was fully validated over the concentration range of 0.100-50.0 ng/mL and 1.00-500 ng/mL in plasma and urine, respectively. The lower limits of quantification (LLOQs) were 0.100 and 1.00 ng/mL in plasma and urine, respectively. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115% for both plasma and urine. Extraction recovery was 82.1% and 56.6% in plasma and urine, respectively. Selectivity, matrix effects and stability were also validated in human plasma and urine. The method was applied to the pharmacokinetic study of higenamine hydrochloride in Chinese healthy subjects.  相似文献   

18.
A simple, rapid and sensitive method for the determination of iothalamic acid (IA) in both plasma and urine is reported. After extraction with ethyl acetate, IA was determined by strong anion-exchange high-performance liquid chromatography with ultraviolet detection at 254 nm. The lower limit of detection was 0.5 μg/ml. The average recovery was 73 and 57% from plasma and urine, respectively. Linearity was found over the investigated concentration range (up to 500 μg/ml for plasma and up to 10.0 mg/ml for urine). The reproducibility of the technique was good (coefficient of variation less than 6%) as was the precision and accuracy (coefficient of variation less than 2.5%). No interference from endogenous substances or any of the common drugs tested was found.  相似文献   

19.
A method for the determination of organotin compounds in urine samples based on liquid–liquid extraction (LLE) in hexane and gas chromatographic separation was developed and optimized. Seven organotin species, namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), tetrabutyltin (TeBT), monophenyltin (MPhT), diphenyltin (DPhT) and triphenyltin (TPhT), were in situ derivatized by sodium tetraethylborate (NaBEt4) to form ethylated less polar derivatives directly in the urine matrix. The critical parameters which have a significant effect on the yield of the successive liquid–liquid extraction procedure were examined, by using standard solutions of tetrabutyltin in hexane. The method was optimized for use in direct analysis of undiluted human urine samples and ways to overcome practical problems such as foam formation during extraction, due to various constituents of urine are discussed. After thorough optimization of the extraction procedure, all examined species could be determined after 3 min of simultaneous derivatization and extraction at room temperature and 5 min phase separation by centrifugation. Gas chromatography with a microwave-induced plasma atomic emission detector (MIP-AED) as element specific detector was employed for quantitative measurements, while a quadrupole mass spectrometric detector (MS) was used as molecular specific detector. The detection limits were between 0.42 and 0.67 μg L?1 (as Sn) for the quantitative LLE–GC–MIP-AED method and the precision between 4.2% and 11.7%, respectively.  相似文献   

20.
The validation of a solid-phase extraction and an ion pair high-performance liquid chromatographic assay for the determination of nedocromil sodium (NCS) in urine samples following oral and inhaled administration to healthy volunteers is described. NCS and its internal standard sodium cromoglycate (SCG) were extracted from urine samples using solid-phase extraction and then quantified using high-performance liquid chromatography (HPLC). A 25-cm C8 Spherisorb 5 μm stationary phase with a mobile phase containing a long alkyl chain ion-pair reagent (methanol–0.045 M phosphate buffer–0.05 M dodecyl triethyl ammonium phosphate; 550:447.6:2.4, v/v) was used. The mean (S.D.) intra-day accuracy and precision of the HPLC assay was 99.9 (1.6) and 7.05 (4.9)%, respectively. These values for the inter-day data were 102.4 (4.07) and 10.5 (2.7)%, respectively, over the concentration range investigated. The method described permits the detection of NCS in human urine at concentrations as low as 0.04 μg ml−1 where the signal-to-noise ratio is greater than 3:1. In 10 healthy volunteers a significantly greater amount of NCS was excreted in the urine following inhalation than after oral dosing (p<0.001). The mean (S.D.) amount of NCS renally excreted at 0.5, 1.0 and 24 h following inhalation of four 2-mg doses of NCS from a metered dose inhaler (MDI) was 0.513 (0.24), 1.163 (0.49) and 4.00 (1.73)% of the nominal dose. Similar values after oral administration of 8 mg of NCS were 0.026 (0.03), 0.079 (0.06) and 0.930 (0.74)%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号